DAIKIN VRV AHU

Read th User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1.

PDF Daikin Vrv Ahu

daikin ductable ac catalogue individual user control and reliability in one exible package. Features Compact design Easy to install Superior performance We are provided these duct air conditioners at a very reasonable price. FXZQ12TAVJU.

PDF preview unavailable. Download the PDF instead.

Daikin AHU Catalogue (Draft)
Warning - Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. - Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. - Read th User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer.
Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
DAIKIN AIR CONDITIONING (SINGAPORE) PTE LTD 10 Ang Mo Kio Industrial Park 2. Singapore 569501 Phone: +65-5583-8888 Facsimile: +65-6349-7311 Website: www.daikin.com.sg
Specifications, designs and other content appearing in this brochure are current as of August 2018 but subject to change without notice.
© All rights reserved

Improve Indoor Air Quality

DAIKIN VRV AHU SYSTEM
Standard Series AHURS-DBV Outdoor Air Series AHURS-DBL

Easy Installation

Wide Range of Add-on Options

DSP-VRVAHU-18001

Fan Array Air Flow Range

NO. OF FAN

AIR FLOW RANGE (m3/s)

1-FAN

0.67-4.1

2-FAN ARRAY

1.34 -8.2

4-FAN ARRAY

2.68 - 16.4

6-FAN ARRAY

4.02 - 24.6

8-FAN ARRAY

5.36 - 32.8

* RATED AT TOTAL PRESSURE 800Pa

VRV AHU Applications

Hospital

Shopping Mall

Lobby

Showroom

Factory

Airport

Warehouse

Sports Hall

VRV AHU

Features of VRV AHU
· Harnessing VRV VRT technology
· Inverter controlled system
· Can be easily controlled via standard wired remote control (BRC1E62) (only for standard model)
· Comes in double skin panel model (Single skin option available)
· Easily managed using intelligent Touch Manager central control system - Communication protocol using DIII-Net to communicate with all existing Daikin communication devices. (option to connect directly to BACnet® BMS)
· Can be placed indoor or outdoor*¹
6 Benefits of using VRV AHU
· Quality and warranty assured - VRV AHU are manufactured by Daikin factory.
· Ease of installation - No additional system such as cooling tower, chiller, and long water piping system are required. This also reduces the total system maintenance costs. - Flexible design of the ducting system.
· Cover large area with different ducting configuration.
· VRV AHU can provide ESP up to 500Pa*2 (Standard Model)
· Total solution concept - Integrating an AHU into the total building climate system enables both design and installation procedures to be based on a single common technology. This simplifies project follow-up, installation, commissioning and maintenance since only one party is involved.
· VRV AHU system can be combined with other types of indoor units to operate concurrently.

Options
Wide range of options to meet design requirements. Please contact Daikin's Sales Office on options below:
· Fan Type - Backward Curve Aerofoil - Plug Fan - Electronically Commutated Fan (EC Fan)
· Fan Motor control - VSD - Fixed Speed
· AHU Coil Material Type - Copper Fin - Blue Fin - Epoxy Coated Fin and Coil
· AHU Drain Pan Type - Acrylic Enamel with Steel Coating - Galvanized Steel
· AHU Air Filter Type - Medium Filter - Extra Filter - Synthetic - Bag - HEPA - Aluminum - Cartridge - ULPA
· Special Option - Electric Heater - Mixing Box - Outdoor Roof - Heat Pipes - Motor Starter Box
· Customisation - Airflow - Capacity - ESP - Discharge Direction - Heat Recovery Wheel - Piping Outlet
· Controller for Outdoor Air Series - MicroTech lll*3 (DDC)

01 01

Notes: *1 Optional items required *2 For ESP more than 500Pz, please contact Daikin's Sales Office *3 BACnet interface

02

VRV AHU Introduction
Daikin released 2 series of VRV AHU, standard series model AHURS-DBV and outdoor air series model AHURS-DBL. It is a DX AHU that is specially designed to operate with VRV outdoor unit. This enabled the users to reduce maintenance costs and enjoy more space savings.
Daikin VRV AHU improves the indoor air quality caused by haze, pollutants, etc with options of pre-filers and primary filters. This is the only total AHU solutions provided and manufactured completely by Daikin.

Total Daikin Solutions
(All products manufactured by Daikin Factory)

Air Handling Unit

Control Wiring
Remote Control Wiring (P1P2) Liquid
Gas

VRV AHU System Schematic

VRV AHU Application

From small to large commercial spaces, Daikin offers a wide range of R-410A inverter condensing units for use in conjunction with Air Handling Units (AHU) from 6 HP to 120 HP.

Daikin AHU represents the ideal solution for large storage places, atrium, lobby, banquet halls, showrooms, exhibition halls, shopping malls, etc.

AHU provides large air volumes and high ESP (External Static Pressure) enabling the use of extensive ductworks. The refrigerant flows through the copper pipes using R-410A and operates like a large VRV fan coil unit.

It also has the options to customize the specifications such as the filtration type, direction of air in-take and discharge, service access door and blower type (backward or forward curves and plug fan).

What is VRV?
Daikin VRV system is a multi-split type air conditioner for commercial buildings that uses variable refrigerant flow control invented by Daikin.
It enables long piping length up to 165m and maximum level difference (between outdoor and indoor units) of 90m to provide more design flexibility which can match even large-sized buildings.
It allows one touch selection control using intelligent Touch Manager and includes options to link with BACnet® to enhance the Building Management System (BMS).

03

Nomenclature
AHURS 06 DB V AHURS 06 DB V

DX Air Handling Unit Horizontal Mount Cooling Capacity: 06 = 6HP Double skin 50mm thickness V: Standard | L: Outdoor Air

VRV AHU

Comparison Table and Diagram for Conventional AHU System and VRV AHU System

Conventional AHU System

VRV AHU System

Require Frequent Maintenance (Cooling Tower + Chiller)

Easy Maintenance (same as common A/C System)

Higher Cost Due to Frequent Maintenance

No Additional Maintenance Cost

Require Larger Installation Space (AHU, Chiller, Coolong Tower) Require Small Installation Space (AHU, VRV)

Complex System (HVAC Ducting, Chiller and Water Piping)

Simple System (HVAC Ducting)

Complex Control (Variable Frequency Device, Variable Air Volume Control)
Cooling Tower

Simple Control (Remote Control / Intelligent Touch Manager / MicroTech III Controller)
Free space

Office

Office

AHU

Office Lobby

Chiller

Basement Carpark

Conventional AHU System

Office

VRV IV Max. 90m

Office

AHU

Office Lobby

Basement Carpark
VRV AHU System

04

Standard Series AHURS-DBV
VRV AHU Introduction Standard Series
The VRV AHU standard series are available from the capacity range of 6 HP to 120 HP, also with airflow ranging from 3,240 CMH - 59,760 CMH.

VRV AHU Capacity

120 HP (336 kW)

100 HP (280 kW)

80 HP (224 kW)

60 HP (168 kW)

48 HP (135 kW)

40 HP (114 kW)

32 HP (90.0 kW)

20 HP (55.9 kW)

9,960

16 HP (45.0 kW)

8,160

10 HP (28.0 kW) 4,680

8 HP (22.4 kW) 4,080

6 HP (16.0 kW) 3,240

29,880 24,480 19,920 16,320

39,840

49,800

59,760

0

10,000 20,000 30,000 40,000 50,000 60,000

CMH

Expanded Line Up for Daikin VRV Indoor Series
Comparison for External Static Pressure and Capacity between VRV AHU and Duct Typed Unit VRV AHU offers higher ESP and Capacity as compared to duct type fan coil unit.

FXMQ

VRV AHU

0

200

400

600

External Static Pressure (Pa)

FXMQ: From 100 Pa to 270 Pa VRV AHU: 250 Pa to 500 Pa

*For ESP more than 500 Pa, please contact Daikin's Sales Office

FXMQ VRV AHU
0

10 20 30 40 50 60 70 80 90 100 110 120 Capacity (HP)

FXMQ: From 2 HP to 10 HP VRV AHU: 6 HP to 120 HP

Entering Air Temperature to VRV AHU
Outdoor Unit VRV IV
Expansion Valve
Standard series PCB

Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum

Temperature Range Cooling 14°C WB
35°C DB / 25°C WB -5°C DB 49°C DB -5°C DB 46°C DB -10°C DB 40°C DB

VRV AHU Operation Range
VRV AHU AHURS-DBV operation is similar as other VRV indoor unit. Following table is the list of operation range for AHU.

05

H1 = 90m *¹

AHURS-DBV (Standard Series)

"d"
"c" "f"
"e"
"b" "a"

H3 = 5m

H2 = 15m

VRV AHU System Structure (Maximum Allowable Piping Length and Height)
AHURS-DBV (Standard Series)
1. Longest Pipe Length = a + b + c + d = 165m 2. Longest Pipe Length after First Refnet = c + d = 40m 3. Total Pipe Length = a + b + c + d + e + f = 1,000m
* 1 When level differences are 50m or more, the diameter of the main liquid piping size must be increased. If the outdoor unit is above the indoor unit, a dedicated setting on the outdoor unit is required. Please contact Daikin's Sale Office for more information.

Possibility Z (Ts/Tr control):
Using Daikin wired remote controller (BRC1E62 - optional) Set point can be fixed via standard Daikin wired remote controller. Remote ON/OFF can be achieved by an optional adapter KRP4AA51.
No additional external controller is required. The cooling load is determined from the air suction temperature and set point on the Daikin remote controller.

ON/OFF
KRP4AA51
Daikin Standard series PCB

Ts Te
AHU
BRC1E62
Tr

Room

Ts = Air suction temperature Te = Evaporating Temperature

Tr = Room temperature

AHU = Air Handling Unit

VRV AHU Standard Series Evaporator
AHURS-DBV standard series model use DX coil. Each DX coil will be connected to an expansion valve and controlled by one standard series PCB.
VRV AHU Standard Series Evaporator Coils
· 5 capacities of Evaporator Coils
- 6HP used on 6HP AHU unit - 8HP used on 8HP AHU unit - 1OHP used on 10HP AHU unit - 16HP used on 16HP, 32HP,
48HP AHU unit - 20HP used on 20HP, 40HP,
60HP, 80HP, 100HP, 120HP AHU unit

06

AHURS-DBV (Standard Series)
VRV Connection to AHU Configuration
VRV 6 - 20 HP
Control Wiring Remote Control Wiring (P1P2) Liquid Gas
Single VRV System Configuration

Up to 120 HP Max.6 circuits
Control Wiring Remote Control Wiring (P1P2) Liquid Gas
07

Each coil up to 20 HP (Max combination of 6) = 120 HP

AHURS-DBV (Standard Series)

VRV 6-120 HP

Control Wiring Remote Control Wiring (P1P2) Liquid Gas
Multiple Indoor Units with AHU Configuration *In case of more than 60 HP system, connection is Multiple VRV system

VRV 20 HP

VRV 20 HP

VRV 20 HP

Control Wiring Remote Control Wiring (P1P2) Liquid Gas

Multiple VRV System Configuration

08

AHURS-DBV (Standard Series)

AHU Specification AHURS-DBV

1

CASING / INSULATION (DB SERIES)

50mm Thickness Double Skinned Polyurethane Insulated Sandwich Panel 0.5mm thick Pre-Painted (white) Galvanised Steel Thermal Break System, Ozone friendly Polyurethane Foam 45±2kg/m3

2

CASING-FRAME (DBL SERIES)

Extruded Aluminium Pentapost Profile

COIL

DX Coil

TUBE

Copper Tube

3

FIN

HEADER

Aluminium 0.2mmt, Corrugated Fin Pattern c/w Ripple Edge Copper Tube

FRAME

Galvanised Steel

WORKING PRESSURE 10Kg/cm²

FAN

(Brand = Kruger)

TYPE
4 WHEEL

Double Width Double Inlet Forward Curved Cetrifugal Belt Drive Fan Galvanised Steel

HOUSING

Galvanised Steel

FRAME

Steel With Polyester Powder Coating

5 MOTOR

(Brand = Elektrim) Three-Phase Induction Motor Totally Enclosed Fan-Cooled Type Protection = IP55 Insulation Class = F Efficiency class IE3

6

VIBRATION ISOLATOR

Spring Isolator

7

DRAIN PAIN (DBL SERIES)

1.2mm (SUS 304) Beneath the Drain Pan is Covered with PU Insulation 40Kg/m³ Density

8

AIR FILTER

(Brand = AAF) Type = R29 Class = G3 (AFI = 80-85%) Synthetic Washable Size = Full (24" x 24" x 2") Half (12" x 24" x 2")

AHM Model and Dimensions

Model

Dimensions W x D x H (MM)

AHURS06DBV 1300 x 1400 x 1200

AHURS08DBV 1300 x 1400 x 1200

AHURS10DBV 1500 x 1400 x 1200

AHURS16DBV 1800 x 1500 x 1200

AHURS20DBV 2100 x 1600 x 1200

AHURS32DBV 1800 x 1800 x 1600

AHURS40DBV 2100 x 1800 x 1600

AHURS48DBV 1800 x 1950 x 2300

AHURS60DBV 2100 x 1950 x 2300

AHURS80DBV 4000 x 1800 x 1600

AHURS100DBV 4000 x 1950 x 2300

AHURS120DBV 4000 x 1950 x 2350

09

Drawing
(W)

(D) 140

AHURS-DBV Specifications (AC Motor)

AHURS-DBV (Standard Series)

Model Dimension (WxDxH)mm

AHURS 06 DBV 1300 x 1400 x 1200

AHURS 08 DBV 1300 x 1400 x 1200

AHURS 10 DBV

AHURS 16 DBV

1500 x 1400 x 1200 1800 x 1500 x 1200

AHURS 20 DBV 2100 x 1600 x 1200

AHURS 32 DBV 1800 x 1800 x 1600

Total Cooling Capacity Total Sensible Cooling Capacity

NETT (KW) 16.2 16.1 16.0 15.9 15.8 15.7 22.9 22.8 22.7 22.6 22.4 22.3 28.4 28.3 28.1 28.0 27.9 27.8 45.9 45.7 45.5 45.3 45.1 44.8 56.6 56.4 56.2 55.9 55.7 55.5 91.1 90.8 90.5 90.2 89.9 89.5 11.1 11.0 10.9 10.8 10.7 10.6 15.9 15.8 15.7 15.6 15.5 15.3 19.4 19.3 19.2 19.0 18.9 18.8 31.2 31.0 30.8 30.6 30.4 30.2 37.9 37.7 37.5 37.3 37.0 36.8 62.5 62.2 61.9 61.6 61.2 60.9

Total Cooling Capacity

17.4

24.1

29.8

48.3

59.3

95.7

Total Sensible Cooling GROSS (KW)

12.2

17.1

20.8

33.9

40.7

67.1

Capacity

Air Flow

CMH

3,240

4,080

4,680

8,160

9,960

16,320

Ent. Temp.

°CDB/°CWB

27.00/19.00

27.00/19.00

27.00/19.00

27.00/19.00

27.00/19.00

27.00/19.00

Lev. Temp.

°CDB/°CWB

14.79/13.48

14.51/12.84

13.54/12.06

14.67/12.8

14.89/12.8

14.74/12.88

Coil Material

Cooling Medium

Face Area Per Coil

m2

0.41

0.47

CU TUBE/AL FIN

R410A

0.63

0.79

1.01

0.79

Face Velocity

m/s

2.19

2.38

2.08

2.86

2.75

2.85

Air Pressure Drop In Coil

Pa

108

149

125

186

178

186

Suction Pipe

mm

9.5

9.5

9.5

12.7

15.9

12.7 x 2

Liquid Pipe

mm

19.1

19.1

22.2

28.6

28.6

28.6 x 2

Air Filter Size 12"x24"x2" PCS.

1

1

1

1

-

2

Air Filter Size 24"x24"x2" PCS.

1

1

1

2

3

4

Air Pressure Drop In Filter

Pa

80

80

80

80

80

80

Fan Type

FORWARD CURVE

Fan Model

FDA 200 CM

FDA 250 TM

FDA 250 TM

FDA 315 TM

FDA 355 TM

FDA 450 TM

External Static Pressure Total Static Pressure Motor Rated

Pa

250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500

Pa

438 488 538 588 638 688 479 529 579 629 679 729 455 505 555 605 655 705 518 568 616 666 716 766 508 558 608 658 708 758 516 568 616 686 716 768

KW

1.5

2.2

2.2

3.0

2.2

3.0

4.0

5.5

4.0

5.5

7.5

Full Load Current

Amp 3.63

4.52

4.42

6.33

4.42

6.33

7.95

10.67

7.95

10.67

14.09

Motor Type

(IE3)

Power Supply

415V/3PH/50Hz

Power Input

KW

1.44 1.53 1.64 1.76 1.89 1.99 1.44 1.57 1.67 1.81 1.96 2.12 1.69 1.83 1.94 2.09 2.21 2.36 3.22 3.45 3.68 3.92 4.14 4.38 3.31 3.63 3.87 4.13 4.28 4.57 5.38 5.72 6.09 6.46 6.85 7.24

WATT/CMH

W

0.45 0.47 0.51 0.54 0.58 0.61 0.35 0.38 0.41 0.44 0.48 0.52 0.36 0.39 0.42 0.45 0.47 0.51 0.39 0.42 0.45 0.48 0.51 0.54 0.33 0.36 0.39 0.41 0.43 0.46 0.33 0.35 0.37 0.40 0.42 0.44

KW/RT

KW

0.29 0.31 0.33 0.36 0.38 0.40 0.21 0.23 0.24 0.26 0.29 0.31 0.20 0.22 0.23 0.25 0.26 0.28 0.23 0.25 0.27 0.28 0.30 0.32 0.20 0.22 0.23 0.24 0.25 0.27 0.20 0.21 0.22 0.24 0.25 0.27

Equipment Weight

kg

455

460

460

465

510

520

620

630

700

720

850

Model Dimension (WxDxH)mm

AHURS 40 DBV 2100 x 1800 x 1600

AHURS 48 DBV 1800 x 1950 x 2300

AHURS 60 DBV

AHURS 80 DBV

2100 x 1950 x 2200 4000 x 1800 x 1600

AHURS 100 DBV 4000 x 1950 x 2300

AHURS 120 DBV 4000 x 1950 x 2350

Total Cooling Capacity NETT (KW) 113.1 112.7 112.3 111.9 111.5 111.1 136.9 136.4 136.0 135.5 135.0 134.5 170.0 169.4 168.8 168.1 167.5 166.7 227.3 226.5 225.6 224.8 223.9 223.0 283.8 282.8 281.8 280.8 27.8 278.8 341.3 340.0 338.8 377.4 336.0 334.6

Total Sensible Cooling Capacity

75.8 75.4 75.0 74.6 74.2 73.7 98.1 97.7 97.2 96.7 96.3 95.8 113.9 113.3 112.7 112.1 111.5 110.7 151.7 150.9 150.0 149.2 148.3 147.4 198.5 197.5 196.5 195.5 194.5 193.5 227.7 226.4 225.2 223.8 222.4 221.0

Total Cooling Capacity

118.7

143.4

178.0

239.2

297.1

358.5

Total Sensible Cooling GROSS (KW)

81.3

104.6

122.0

163.6

211.8

224.9

Capacity

Air Flow

CMH

19,920

24,480

29,880

39,840

49,800

59,760

Ent. Temp.

°CDB/°CWB

27.00/19.00

27.00/19.00

27.00/19.00

27.00/19.00

27.00/19.00

27.00/19.00

Lev. Temp.

°CDB/°CWB

14.89/12.8

14.32/12.91

14.89/12.8

14.81/12.73

14.38/12.78

14.82/12.74

Coil Material

Cooling Medium

Face Area Per Coil

m2

1.01

0.79

CU TUBE/AL FIN

R410A

1.01

2.04

1.26

2.04

Face Velocity

m/s

2.77

2.88

2.77

2.70

2.20

2.70

Air Pressure Drop In Coil

Pa

178

188

178

174

135

174

Suction Pipe

mm

15.9 x 2

12.7 x 3

159 x 3

15.9 x 4

15.9 x 5

15.9 x 6

Liquid Pipe

mm

28.36 x 2

28.6 x 3

28.6 x 3

28.6 x 4

28.6 x 5

28.6 x 6

Air Filter Size 12"x24"x2"

PCS.

-

3

-

-

-

-

Air Filter Size 24"x24"x2"

PCS.

6

6

9

12

18

18

Air Pressure Drop In Filter

Pa

80

80

80

80

80

80

Fan Type

FORWARD CURVE

Fan Model

FDA500 TM

FDA560 TM

FDA630 TM

FDA500 T2M

FDA560 T2M

FDA630 T2M

External Static Pressure Total Static Pressure Motor Rated

Pa

250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500

Pa

50.8 558 608 658 708 758 518 588 618 668 718 768 508 558 608 658 708 758 504 554 604 654 704 754 465 515 565 615 665 715 504 554 604 654 704 754

KW

7.5

11.0

11.0

11.0

15.0

15.0

18.5

22.0

18.5

22.0

22.0

30.0

Full Load Current

Amp

14.1

20.7

20.7

20.7

27.3

27.3

33.5

39.2

33.5

39.2

39.2

57.1

Motor Type

(IE3)

Power Supply

415V/3PH/50Hz

Power Input

KW

6.47 6.93 7.31 7.77 8.25 8.73 7.49 8.02 8.52 9.08 9.60 10.17 1.69 1.83 1.94 2.09 2.21 2.36 13.60 14.44 15.46 16.37 17.39 18.34 15.12 16.26 17.39 18.53 19.58 20.71 19.47 20.94 22.15 23.73 25.30 26.88

WATT/CMH

W

0.33 0.35 0.37 0.39 0.41 0.44 0.31 0.33 0.35 0.37 0.39 0.42 0.36 0.39 0.42 0.45 0.47 0.51 0.34 0.36 0.39 0.41 0.44 0.46 0.30 0.35 0.35 0.37 0.39 0.39 0.33 0.35 0.37 0.40 0.42 0.45

KW/RT

KW

0.19 0.21 0.22 0.23 0.24 0.26 0.16 0.20 0.21 0.22 0.24 0.25 0.20 0.22 0.23 0.25 0.26 0.28 0.20 0.21 0.23 0.24 0.26 0.27 0.18 0.19 0.21 0.22 0.23 0.23 0.19 0.21 0.22 0.23 0.25 0.26

Equipment Weight

kg

960

1000

1230

510

520

620

630

2165

2200

850

10

Outdoor Air Series AHURS-DBL
VRV AHU Outdoor Air Series
The VRV AHU Outdoor air series are available from the capacity range of 8 HP to 60 HP, also with airflow ranging from 2,040 CMH - 16,280 CMH.

VRV AHU Capacity

60 HP (168 kW) 48 HP (135 kW) 40 HP (114 kW)

32 HP (90.0 kW) 20 HP (55.9 kW) 16 HP (45.0 kW)

5,460 4,080

10 HP (28.0 kW) 8 HP (22.4 kW)

2,340 2,040

0

3,000

6,000

12,240 10,920 8,160

9,000 CMH

12,000

16,380
15,000 18,000

Comparison for ESP and Capacity between VRV AHU, Ceiling Mounted Duct Type and Floor Standing Duct Type.
VRV AHU offers higher ESP and airflow rate as compared to duct type units.

FXMQ-V1

FXMQ VRV AHU

0

200

400

600

External Static Pressure (Pa)

FXMQ-V1: From 185 Pa to 205 Pa FXMQ: From 150 Pa to 480 Pa VRV AHU: 250 Pa to 500 Pa

FXMQ-V1 FXMQ
VRV AHU

0 1000 2000 3000 4000 5000 6000 Airflow Rate (CMH)
FXMQ-V1: From 1,080 CMH to 2,100 CMH FXMQ: From 1,518 CMH to 6,072 CMH VRV AHU: 2,040 CMH to 16,380 CMH

7000

8000 16000 17000

*For ESP more than 500 Pa, please contact Daikin's Sales Office

Entering Air Temperature to VRV AHU
Outdoor Unit VRV IV
Expansion Valve
Outdoor air series PCB

Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum

Temperature Range Cooling 14°C WB 35°C DB -5°C DB 49°C DB -5°C DB 46°C DB -10°C DB 40°C DB

VRV AHU Operation Range
VRV AHU AHURS-DBL operation is similar as other VRV indoor unit. Following table is the list of operation range for AHU.

11

Outdoor Air Series AHURS-DBL

H1 = 30m

"d"
"c" "f"
"e"
"b" "a"

H3 = 5m

H2 = 15m

VRV AHU System Structure (Maximum Allowable Piping Length and Height)
AHURS-DBL (Outdoor Air Series)
1. Longest Pipe Length = a + b + c + d = 165m
2. Longest Pipe Length after First Refnet = c + d = 40m
* 1 When level differences are 50m or more, the diameter of the main liquid piping size must be increased. If the outdoor unit is above the indoor unit, a dedicated setting on the outdoor unit is required. Please contact Daikin's Sale Office for more information.

VRV AHU Outdoor Air Series Evaporator Coil, Expansion Valve and Outdoor Air Series PCB
AHURS-DBL Outdoor air series use DX coil. Each DX coil will be connected to expansion valve and controlled by one Outdoor air series PCB. VRV AHU Outdoor air Series Evaporator Coils
· 4 capacities of Evaporator Coils
- 8HP used on 8HP AHU unit - 10HP used on 10HP AHU unit - 16HP used on 16HP, 32HP, 48HP
AHU unit - 20HP used on 20HP, 40HP,
60HP AHU unit

Possibility X (Td/Tr control):
Precise air temperature control via MicroTech III (MT III) controller (option)
Room temperature is controlled as a function of the air handling unit suction or discharge air (customer selection). The MT III controller translates the temperature difference between set point and air suction temperature (or air discharge temperature or room temperature) into a reference voltage (0-10V) which is transferred to the Daikin Outdoor air series PCB.
This Reference voltage will be used as the main input value for the compressor frequency control.

MT III

AHU

Daikin Outdoor air series PCB

Room

Td = Air discharge temperature Temperature (13°C ~ 28°C)

Te = Evaporating AHU = Air Handling Unit

MicroTech III controller (option)
MT III controller is recommended for Outdoor air series AHU controlling, switching and monitoring functions. This controller is programmed to optimize the performance and efficiency of VRV AHU automatically. It can also communicate with Daikin's intelligent Touch Manager via BACnet protocol easily.

12

Outdoor Air Series AHURS-DBL VRV AHU Configuration

MT III Controller (option)

Control Wiring MT III Control Wiring Liquid Gas

Combined VRV System Configuration

VRV 20 HP

VRV 20 HP

VRV 20 HP

Control Wiring Remote Control Wiring (P1P2) Liquid Gas

Multiple VRV System Configuration

13

Outdoor Air Series AHURS-DBL

VRV AHU Configuration

1

CASING / INSULATION (DBL SERIES)

50mm Thickness Double Skin Polyurethane Insulated Sandwich Panel 0.5mm thick Pre-Painted (white) Galvanised Steel Thermal Break System, Ozone friendly Polyurethane Foam 45±2kg/m3

WEATHER PROOF ROOF SUS 304

2

CASING-FRAME (DBL SERIES)

Extruded Aluminium Profile

COIL

DX Coil

TUBE

Copper Tube

3

FIN

HEADER

Aluminium Fin, 0.2mm, Corrugated Fin Pattern c/w Ripple Edge Copper Tube-Connect

FRAME

Galvanised Steel

WORKING PRESSURE

10Kg/cm²

FAN

(Brand = Kruger)

TYPE

Double Width Double Inlet Forward Curved Cetrifugal Belt Drive Fan

4 WHEEL

Galvanised Steel Sheet

HOUSING

Galvanised Steel Sheet

FRAME

Steel With Polyester Powder Coating

5 MOTOR

6

VIBRATION ISOLATOR

(Brand = Elektrim) Three-Phase Induction Motor Totally Enclosed Fan-Cooled Type Protection = IP55 Insulation Class = F Efficiency class IE3
Spring Isolator

7

DRAIN PAIN (DBL SERIES)

1.2mm (SUS 304) The Drain Pan is Covered with PU Insulation 40Kg/m³ Density

8

AIR FILTER

(Brand = AAF) Type = R29 Class = G3 (AFI = 80-85%) Synthetic Washable Size = Full (24" x 24" x 2") Half (12" x 24" x 2")

AHM Model and Dimensions

Model

Dimensions W x D x H (MM)

Drawing

AHURS08DBL 1300 x 1400 x 1200

AHURS10DBL 1500 x 1400 x 1200

AHURS16DBL 1800 x 1400 x 1200

AHURS20DBL 2100 x 1600 x 1200

AHURS32DBL 1800 x 1800 x 1600

AHURS40DBL 2100 x 1800 x 1600

(W)

(D)

AHURS48DBL 1800 x 1950 x 2300

AHURS60DBL 2100 x 1950 x 2300

14

Outdoor Air Series AHURS-DBL

AHURS-DBL Specifications (AC Motor)

Model Dimension (WxDxH)mm

AHURS 08 DBL 1300 x 1400 x 1200

AHURS 10 DBL 1500 x 1400 x 1200

AHURS 16 DBL 1800 x 1500 x 1200

AHURS 20 DBL 2100 x 1600 x 1200

Total Cooling Capacity Total Sensible Cooling Capacity

NETT (KW) 23.0 22.9 22.8 22.8 22.7 23.5 27.9 27.8 27.8 27.7 27.6 28.6 45.0 44.9 44.8 44.7 44.6 46.0 56.9 56.8 56.7 56.5 56.4 58.5 9.2 9.2 9.1 9.1 9.0 8.9 11.2 11.2 11.1 11.0 11.0 10.9 18.2 18.2 18.1 18.0 17.9 17.7 22.8 22.7 22.5 22.4 22.3 22.2

Total Cooling Capacity Sensible Cooling Capacity

GROSS (KW)

23.5 9.8

28.6 11.9

46.0 19.2

58.5 24.4

Air Flow Ent. Temp. Lev. Temp. Coil Material

CMH °CDB/°CWB °CDB/°CWB

2,040 33/27 18.81/17.89

2,340 33/27 17.89/17.17

CU TUBE/AL FIN

4,080 33/27 18.96/18.01

5,460 33/27 19.75/18.62

Cooling Medium

R410A

Face Area Per Coil Face Velocity Air Pressure Drop In Coil Suction Pipe Liquid Pipe Air Filter Size 12"x24"x2" Air Filter Size 24"x24"x2" Air Pressure Drop In Filter Fan Type

m2 m/s Pa mm mm PCS. PCS. Pa

0.46 1.23 36 9.5 19.1
1 1 80

0.65 1.20 26 9.5 22.2
2 80

FORWARD CURVE

0.79 1.43 46 12.7 28.6
1 2 80

0.96 1.58 54 15.9 28.6
3 80

Fan Model

FDA180 CM

FDA180 CM

FDA250 TM

FDA250 TM

External Static Pressure Total Static Pressure Motor Rated Full Load Current

Pa

250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500

Pa

366 416 466 516 566 616 356 406 456 506 556 606 376 426 476 526 576 626 384 434 484 534 584 634

KW

0.75

1.1

1.1

1.5

1.5

2.2

2.2

3.0

Amp

1.90

2.62

2.62

3.63

3.63

4.52

4.52

6.33

Motor Type

(IE3)

Power Supply

415V/3PH/50Hz

Power Input

KW 0.70 0.94 0.84 0.92 1.00 1.07 0.86 0.94 1.02 1.08 1.16 1.25 1.21 1.33 1.46 1.55 1.68 1.82 1.97 2.09 2.24 2.40 2.54 2.70

WATT/CMH

W 0.34 0.40 0.41 0.45 0.49 0.53 0.37 0.40 0.43 0.46 0.50 0.53 0.30 0.33 0.36 0.38 0.41 0.45 0.36 0.38 0.41 0.44 0.47 0.49

KW/RT

KW 0.10 0.12 0.13 0.14 0.15 0.16 0.11 0.12 0.13 0.13 0.14 0.15 0.09 0.10 0.11 0.12 0.13 0.14 0.12 0.13 0.13 0.14 0.15 0.16

Equipment Weight

kg

415

420

475

480

550

570

645

650

Model Dimension (WxDxH)mm

AHURS 32 DBL 1800 x 1800 x 1600

AHURS 40 DBL 2100 x 1800 x 1600

AHURS 48 DBL 1800 x 1950 x 2300

AHURS 60 DBL 2100 x 1950 x 2300

Total Cooling Capacity Total Sensible Cooling Capacity

NETT (KW) 90.0 89.9 89.7 89.5 89.3 92.3 114.3 114.1 113.9 113.7113.5 116.6 135.5 135.2 135.0 134.8134.5 138.2 171.6 171.3 170.9 170.6170.2 175.0 36.4 36.2 36.0 35.9 35.7 35.5 46.3 46.1 45.9 45.7 45.5 45.2 54.8 54.6 54.4 54.1 53.9 53.7 69.6 69.3 68.9 68.6 68.2 67.9

Total Cooling Capacity Sensible Cooling Capacity

GROSS (KW)

92.3 38.6

116.6 48.6

138.2 57.6

175.0 73.0

Air Flow Ent. Temp. Lev. Temp. Coil Material

CMH °CDB/°CWB °CDB/°CWB

8,160 33/27 18.96/18.01

10,920 33/27 19.79/18.66

CU TUBE/AL FIN

12,240 33/27 18.98/18.03

16,380 33/27 19.79/18.66

Cooling Medium

R410A

Face Area Per Coil Face Velocity Air Pressure Drop In Coil Suction Pipe Liquid Pipe Air Filter Size 12"x24"x2" Air Filter Size 24"x24"x2" Air Pressure Drop In Filter Fan Type

m2 m/s Pa mm mm PCS. PCS. Pa

0.79 1.43 46 12.7 x 2 28.6 x 2
2 4 80

0.96 1.58 54 15.9 x 2 28.6 x 2
6 80

FORWARD CURVE

0.79 1.43 46 12.7 x 3 28.6 x 3
3 6 80

0.96 1.58 54 15.9 x 3 28.6 x 3
9 80

Fan Model

FDA315 TM

FDA400 TM

FDA400 TM

FDA500 TM

External Static Pressure Total Static Pressure Motor Rated Full Load Current

Pa

250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500 250 300 350 400 450 500

Pa

376 426 476 526 576 626 384 434 484 534 584 634 376 426 476 526 576 626 384 434 484 534 584 634

KW

3.0

4.0

3.0

4.0

5.5

4.0

5.5

4.0

5.5

7.5

Amp

6.33

7.95

6.33

7.95

10.67

7.95

10.67

7.95

10.67

14.09

Motor Type

(IE3)

Power Supply

415V/3PH/50Hz

Power Input

KW 2.65 2.86 3.04 3.27 3.48 3.73 2.76 3.01 3.23 3.52 3.79 4.15 3.27 3.54 3.81 4.08 4.37 4.65 3.98 4.37 4.78 5.18 5.61 6.02

WATT/CMH

W 0.33 0.35 0.37 0.40 0.43 0.46 0.25 0.28 0.30 0.32 0.35 0.38 0.27 0.29 0.31 0.33 0.36 0.38 0.24 0.27 0.29 0.32 0.34 0.37

KW/RT

KW 0.10 0.11 0.12 0.12 0.13 0.14 0.08 0.09 0.10 0.11 0.11 0.13 0.08 0.09 0.10 0.10 0.11 0.12 0.08 0.09 0.10 0.10 0.11 0.12

Equipment Weight

kg

770

790

860

880

900

1080

1100

1265

1300

15

Technical Information

MicroTech III Controller (Option)
MicroTech III consists of 4 components in a fixed configuration

BACnet IP Module POL908

Principal Module POL 638

Extension Module Extension Module

POL 955

POL 955

Features

Functions

1. BACnet IP Module for integration of MicroTech III AHU Controller in networks featuring the BACnet Protocol. Compatible with Daikin intelligent Touch Manager (iTM) or 3rd party BMS.
2. Principal Module POL 638 and Extension ModulePOL 955 have selected analog and digital I/O contacts programmed for control and monitoring of sensors and other related devicesin a VRV Outdoor Air Series AHU.
3. HMI screen on the Principal Module POL 638 allows easy testing and commissioning and even without a centralised controller or 3rd party BMS.

1. Supply air control using the supply air sensor
- Used for temperature control.
2. Air quality control ­CO2 Levels - The controls of the mixing damper can be dependent on the CO2 set point. - User can define the CO2 set point. - The fresh air damper will be difference between 100% and the percentage opening of the mixing damper.
3. Fan airflow control - The fan speed control can be done through i.Direct (w/o inverters). ii.DirectVar(with inverters). iii.Analog controlled variable speed drive with digital release. iv. Pressure control to meet the pressure set points in the duct.

4. Monitoring points for other features
i. Room humidity ii. Electric heating coil iii. Outside, room and return temperature iv. VRV alarm

MicroTech III can connect to intelligent Touch Manager. (iTM Controller)
Monitor and control devices related to AHU such as fan, sensors, and damper

- On/Off - Operation mode - Setpoint - Error monitoring
- CO2 ppm - Discharged air temp - Humidity - Dumper control etc...
VRV AHU
Gas Pipe Liquid Pipe
F1F2

Available object list - BACnet BI/BO/BV - BACnet AI/AO/AV
MicroTech III
CO2

16


Adobe Illustrator CC 22.1 (Macintosh) Adobe PDF library 15.00