The Sinilink XY5008E is a versatile CV/CC (Constant Voltage/Constant Current) DC buck power supply designed for various applications including computer power modification, DIY projects, and desktop power solutions. It features a large, full-view dedicated power LCD for clear display and simple operation.
Key Specifications:
- Input Voltage: 6.0-55.00V
- Output Voltage: 0.0-50.00V
- Output Current: 0-8.100A
- Power Output: 400W
Key Features:
- Complete display
- Simple operation
- Stable performance
- Large screen display
- Full view dedicated power LCD
Product Parameters
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Name | DC buck power supply | Product Model | XY5008E |
Input Voltage | 6.0-55V | Output Voltage | 0.0-50V |
Output Current | 0.000-8.100A | Voltage Accuracy | ±0.4%+1 digit |
Output Power | 0-400W | Current Accuracy | ±0.5%+3 digits |
Voltage Resolution | 0.01V | Soft Boot | YES |
Current Resolution | 0.001A | Conversion Efficiency | About 95% |
Protection Mechanism
The power supply is equipped with comprehensive hardware and software protection features to ensure safe and reliable operation.
Hardware Protection:
- Input anti-reverse connection [✔️]
- Output short-circuit protection [✔️]
Software Protection:
- Input undervoltage protection (LVP): Adjustable from 4.8-30V, default 4.8V
- Output overvoltage protection (OVP): Adjustable from 0-52V, default 52V
- Output overcurrent protection (OCP): Adjustable from 0-8.2A, default 8.2A
- Output overpower protection (OPP): Adjustable from 0-410W, default 410W
- Overtemperature protection: Yes, default 100℃ [?️]
- Timeout protection: Adjustable from 0-100H, default off
- Overcapacity protection: Adjustable from 0-9999AH, default off [?]
- Superenergy protection: Adjustable from 0-9999WH, default off [⚡]
Product Details
Design and Construction
All-in-one molded frosted panel: Provides a durable and aesthetically pleasing front interface.
Premium aluminum alloy knob caps: Offers a good hand feel and precise control.
Intelligent temperature control fan: The fan starts automatically when the temperature exceeds 50°C or the current exceeds 1A, ensuring effective heat dissipation through thickened heatsink and two-way ventilation.
Internal Components:
- 15A ferrosilicon aluminum ring inductor
- Thickened heat sink under the fan
- Pluggable cable terminals for input and output
Terminal Connections:
- Input Positive Pole
- Input Negative Pole
- Output Positive Pole
- Output Negative Pole
Instructions for Use
Entering Parameter Setting Screen
Press and hold the [Switch] (SW) button for 3 seconds to enter the parameter setting screen.
Parameter Setting Interface Overview
The parameter setting screen allows adjustment of various protection thresholds and functions. Parameters include:
- Input undervoltage protection (LVP): Default 4.8V
- Output overvoltage protection (OVP): Default 52.00V
- Output overcurrent protection (OCP): Default 8.200A
- Output overpower protection (OPP): Default 410.0W
- Maximum Capacity (OAH) / Over capacity protection: Default 0.515Ah
- Maximum Energy (OPH) / Super energy protection: Displayed as "----" (disabled)
- Timeout protection (OHP): Default 02:40 (hours:minutes)
- Power-on state (PON): Default "On" (enabled)
- Parameter type selection (FET): Select between Constant Voltage (CV) or Constant Current (CC) mode. Default voltage is CV, default current is CC. "OFF" indicates no action.
Setting Parameters:
- Enter Setting Screen: On the running screen, hold down the [Switch] (SW) button for 2 seconds.
- Select Parameter: Press the [Switch] (SW) button to cycle through parameters.
- Adjust Value: Use the rotary encoder to adjust the selected parameter's value. Press the encoder button to switch between digits for fine-tuning.
- Enable/Disable Functions (OAH/OPH/OHP): On the respective screens, press the [Power On/Off] (ⓘ) button to enable or disable the function. If disabled, "----" will be displayed.
- Set Capacity/Energy Range: On the OAH/OPH screens, hold down the [Power On/Off] (ⓘ) button to select ranges (e.g., 9.999Ah/99.999AH/9999Ah, 9.999Wh/99.999WH/9999Wh).
- Exit Setting Screen: After completing settings, hold down the [Switch] (SW) button for 2 seconds to exit. Settings are automatically saved.
1. Set Voltage and Current:
In the operation interface:
- Press the [Voltage/Amperage] (V/A) button to enter the voltage/current setting interface. The LCD will display "SET" and "CV" will flash.
- Press the [Switch] (SW) button or rotate the encoder to select the voltage digit to blink, then adjust the voltage using the rotary encoder.
- Press the [Voltage/Amperage] (V/A) button again. The LCD will display "SET" and "CC" will flash.
- Press the [Switch] (SW) button or rotate the encoder to select the current digit to blink, then adjust the current using the rotary encoder.
- Press the [Voltage/Amperage] (V/A) button again to exit and save settings.
- Alternatively, long press the [Voltage/Amperage] (V/A) button for 2 seconds or wait 6 seconds without operation to automatically exit and save.
2. Quick Setting of Voltage or Current:
In the parameter setting interface, set the parameter FET to CV or CC. Then, in the operation interface, use the rotary encoder to quickly set the voltage or current.
- FET set to CV: Default voltage is CV.
- FET set to CC: Default current is CC.
- FET set to OFF: No action.
3. Setting Parameters:
Detailed steps for setting parameters are covered in the "Parameter Setting Interface Overview" and "Setting Parameters" sections above.
4. Input and Output Voltage Display:
On the running interface, press the [Switch] (SW) button to toggle between displaying the input voltage (labeled "IN") and the output voltage.
Example: Input voltage displayed as IN 12.00V, Output voltage 24.00V, Current 1.431A, Power 34.34W.
5. View Power (W) / Capacity (Ah) / Energy (Wh) / Time (h):
In the operation interface, press the rotary encoder button to cycle through and display:
- Power (W)
- Capacity (Ah)
- Energy (Wh)
- Time (h)
Example display: 34.34W power, 0.156Ah capacity, 4.264Wh energy, 04:07 time.
6. Locking Function:
To prevent accidental misoperation:
- In the operation interface, long press the rotary encoder button for 2 seconds to lock the voltage and current settings. A display lock symbol [?] will appear.
- Long press the rotary encoder button for 2 seconds again to unlock.
7. Details of Other Functions:
7.1 Capacity/Energy/Running Time Statistics:
- Statistics start automatically when the power is turned ON.
- When the power is turned OFF, the previous recorded values are displayed.
- When the power is turned ON again, the record restarts automatically.
- On the corresponding statistics screen, press and hold the [Power On/Off] (ⓘ) button for 2 seconds to clear the data.
7.2 Setting Maximum Capacity, Maximum Energy, and Maximum Running Time:
- Maximum Capacity (OAH) / Maximum Energy (OPH): When these functions are active, if the measured capacity/energy exceeds the set maximum, the power supply will automatically shut down output and flash "OAH" or "OPH". Statistics clear automatically after the alarm is resolved.
- Maximum Discharge Time (OHP): When this function is active, if the running time exceeds the set maximum, the power output will automatically turn off and "OHP" will blink. Time statistics clear automatically after the OHP alarm is lifted.
These functions enable quantitative and timed power supply operations.
Note:
- When OAP/OPH and OHP functions are NOT enabled, the power supply automatically records capacity/energy and running time.
- When OAH/OPH and OHP functions ARE enabled, the power supply automatically shuts down output after reaching the set value.
- With OHP enabled, the running time operates in countdown mode.
Product Dimensions and Packaging
Product Dimensions:
- Width: 79mm
- Height: 43mm
- Depth: 25mm
Suggested Opening Size for Installation:
- Width: 71.3mm
- Height: 39mm
- Cutout dimensions: 75.8mm x 12mm (approximate internal cutout)
Packaging:
The product is individually packed in a paper case.
Related Documents
![]() | Sinilink XY6506/XY6509 DC Buck Power Supply: User Manual and Technical Specifications Comprehensive guide to the Sinilink XY6506 and XY6509 DC buck power supplies, detailing product parameters, UI functions, system settings, protection mechanisms, and MODBUS-RTU communication protocol. |
![]() | Sinilink XY-SK120S/150S DC Buck-Boost Power Supply User Manual Detailed user manual for the Sinilink XY-SK120S and XY-SK150S DC buck-boost power supply, covering product parameters, operation instructions, protection mechanisms, UI functions, and Modbus communication protocol. |
![]() | XY3605 Mini CNC DC Buck-Boost Power Supply User Manual Comprehensive user manual for the XY3605 Mini CNC DC Buck-Boost Power Supply, detailing its features, operation, interfaces, protection mechanisms, and connectivity options. |
![]() | Sinilink XY-S100H 2.1 Channel Bluetooth Audio Power Amplifier Board - Features, Specs, and Guide Comprehensive guide to the Sinilink XY-S100H 2.1 channel Bluetooth audio power amplifier board. Learn about its 50W*2 + 100W output, Bluetooth 5.0, input options (AUX, U disk, USB sound card), APP control, installation, and technical specifications. Includes comparison with XY-S100L. |
![]() | Sinilink XY-E30H 2.1 Channel Bluetooth Audio Power Amplifier Module Detailed information on the Sinilink XY-E30H, a 2.1 channel Bluetooth audio power amplifier module with 15W*2+30W output, covering its design, functions, parameters, installation, and connectivity. |
![]() | Sinilink XY-W50L HIFI Class 50W*2 Stereo Bluetooth Digital Power Amplifier Module with WIFI Timing Clock Comprehensive guide for the Sinilink XY-W50L HIFI Class 50W*2 stereo Bluetooth digital power amplifier module with WIFI timing clock. Covers features, specifications, installation, Bluetooth connectivity, APP control, and Wi-Fi networking. Ideal for audio enthusiasts seeking high-fidelity sound and smart features. |
![]() | Bluetooth Power Amplifier Board Manual XY-S220H User manual for the XY-S220H 2.1 Channel Bluetooth Power Amplifier Board, detailing product parameters, setup instructions, Sinilink APP usage, power supply, speaker selection, and Bluetooth signal considerations. |
![]() | Sinilink XY-WBT Bluetooth Audio Module & WiFi Timing Clock User Manual The Sinilink XY-WBT is a versatile Bluetooth 5.0 stereo audio module with integrated WiFi timing clock functionality. It offers lossless sound quality, 6 alarm groups, 8 brightness levels, global time zone synchronization, and mobile APP control for Android and iOS, including remote firmware upgrades. This module is ideal for converting active speakers into Bluetooth-enabled devices with precise timekeeping. |