As a component of the guestroom Energy Management System, the X45B. Controller Card receives control signals from the guestroom's Smart Digital.
X45B Controller Card Product Guide X45B Controller Card Product Guide Table of Contents Table of Contents .............................................................. Page 1 Overview and General Concept ........................................ Page 2 Application ......................................................................... Page 2 Features............................................................................. Page 2 1 Operational Characteristics ............................................ Page 3 Headers ........................................................................ Page 3 X45B Input Specification............................................... Page 4 Load Ratings ................................................................. Page 6 1.1 Installation .................................................................... Page 6 X06 Line Voltage Connections ..................................... Page 7 Low Voltage Connection............................................... Page 7 2 Size ................................................................................. Page 8 2.1 Mounting and Orientation ............................................ Page 8 Ordering Information.......................................................... Page 8 Specifications..................................................................... Page 9 Approvals........................................................................... Page 9 Documentation Revision History ....................................... Page 9 Rev. 1.0 Date 3/17/2017 1 X45B Controller Card Product Guide Overview and General Concepts The X45B Controller Card (Figure 1) is a CBL32 universal multi-functional controller device that is the sum of the commonly used I/O across the legacy X05B, X529, and modern X47. It is used with the X06 Remote HVAC Controller and in other applications. The X45B logic is managed by an attached MCM1 Logic Board. Application Features Figure 1 X45B Controller Card As a component of the guestroom Energy Management System, the X45B Controller Card receives control signals from the guestroom's Smart Digital Thermostat or other in-room control devices through a low-voltage wired connection or through an infrared (IR) wireless connection when used in conjunction with the INNCOM Eye5 IR transceiver. The control signal triggers the X45B Controller Card to open or close the appropriate relay contact on the X06 Controller, with a corresponding response from the guestroom's HVAC unit or other devices. · S5bus hardened against over voltage · 2 analog inputs for remote thermistor (pin 1 GND, pin2 GND, pin3 AIN) · Analog outputs 0-10VDC · IR5 Header · System 5 Header (pin1 GND, pin2 12VDC, pin 3 S5bus, pin4 I/O1, pin5 I/O2) · X06 relay chassis interface (8-pin connector) · RS485 network interface header · Status LED for each relay · 6 digital input header, with status LED Rev. 1.0 Date 3/17/2017 2 X45B Controller Card Product Guide 1 Operational Characteristics The X45B-X06 is a relay assembly containing a universal power supply. It is used to increase and enhance the output capability of other INNCOM products such as an e4 Digital Thermostat. It is intended for use with · PTAC, heat pump and FCU actuator · Five channel light controller · Master contactor The X45B communicates with the e4 through a wired connection (S5) or RS-485(requires external adapter 203-250) or through an Infrared (RF) wireless connection when used in conjunction with the Eye5 IR transceiver. In addition, X45B supports two external temperature sensors, two analog outputs, seven digital inputs and two general purpose I/Os which can be used as UART interface for communication. Headers H2 RS485 H3 EXT TEMP 2 H4 EXT TEMP 1 H8 System 5 H9 S5bus H5 IR5 EYE IN H10 X06 Relay H11 Digital IN H1 ISP H7 Analog Out Rev.1.0 Date 3/17/2017 3 X45B Controller Card Product Guide X45B Input Specification H1-ISP Programming Header Pin Signal 1 GND 2 VCC 3 SCI2_TX 4 SCI2_RX 5 NRST 6 SWO 7 SWCLK 8 SWDIO H2--Analog Output Pin Signal 1 GND 2 3.3VDC 3 RS485_TX 4 RS485_RX 5 RS485_TXE 6 SWO H3--EXT Temp 2 Pin Signal 1 GND 2 GND 3 EXT Temp 2 H4--EXT Temp 1 Pin Signal 1 GND 2 GND 3 EXT Temp 1 Function Power Power (+3.3V) Transmit Receive Reset Oscillator Clock power Function Power Power (+3.3V) Transmit Receive Reset Oscillator Function Ground Power Transmit Function Ground Power Transmit Rev. 1.0 Date 3/17/2017 4 X45B Controller Card Product Guide H5--IR5 Eye Input Pin Signal 1 GND 2 AGC 3 12VDC 4 IR5TX 5 IR5RX H6--ES2 Pin 1 2 3 4 5 Signal GND 12VDC S5bus SCLK SDATA H7--Analog Output Pin Signal 1 GND 2 Analog Output 3 Analog Output Function Ground Automatic Gain Control Power Transmit Receive Function Ground Power Communication bus Clock Data Function Ground Automatic Gain Control Power H8--System 5 Pin 1 2 3 4 Signal GND 12VDC S5bus I/O 1 5 I/O 2 Function Ground Power Communication bus GPIO (dry contact input, digital output, UART) GPIO (dry contact input, digital output, UART) Rev.1.0 Date 3/17/2017 5 X45B Controller Card Product Guide H9--S5bus Pin 1 2 3 Signal GND 12VDC S5bus Function Ground Power Communication bus Load Ratings X06 General Purpose Load Input 120-277VAC 60 Hz, 110mA K1K6 Relay Output (N.C.) 30A, 240AC, GP 30A, 30VDC 1½ HP 250 VAC 20A, 277VAC, GP K1K6 Relay Output (N.O.) 40A, 240VAC, Res 2HP 250VAC 30A, 277VAC 1.1 Installation When installing this product 1. Read instructions carefully. Failure to follow them could damage the product or create a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for the application. 3. Employ only a trained, experienced service technician for installation. 4. After installation is complete, check product operation as provided with instructions. The X06-X45B comes assembled in a plastic mounting base and power supply enclosure and requires no assembly. X45B card is snapped on top of the X06's universal power supply cover (Part # 53-0195). The X06 is mounted inside a NEMA type enclosure using the mounting holes shown in Figure 4. X06 Line Voltage Connections The X06 output relays use ¼" Spade terminals to connect AC power, earth ground, and wiring to the equipment being controlled. Wiring should be at a minimum 18 gauge stranded rated for 600VAC. Rev. 1.0 Date 3/17/2017 6 X45B Controller Card Product Guide Figure 4: X06-X45B Assembly The Mounting Holes are 0.137" in diameter CAUTION Use UL listed female ¼" connectors. Figure 4 shows spade connectors for connection. · Input power is connected to the X06 at the AC IN Line1 and Line2 terminals. · Earth ground must be connected to the X06 at the EARTH GND terminal or at one of the alternate earth ground plated mounting holes. · Controlled equipment is connected to the X06 Output Relays "NO" and "COM" terminals. These relays are normally open. A harness is provided (INNCOM P/N 62-1498) with the X06 that connects all relay "COM" terminals to the AC IN Line 2 terminal. · Disconnect AC power supply before beginning to prevent electrical shock or equipment damage. · For use with copper wiring only. All wiring must comply with local codes and ordinances. · The X06-X45B assembly must be installed in an appropriate NEMA type enclosure for line voltage safety. · The X06-X45B is intended for INDOOR use only. Low Voltage Connection · X45B can be used in standalone application if relays are not needed. X45B is powered by external power supply in that case. · Section 2.2.4 describes headers available on X45B. Use appropriate cable for the header including S5 bus. Rev.1.0 Date 3/17/2017 7 X45B Controller Card Product Guide 2 Size X45B 75.7mm x 65.54mm x 1.6mm (PWB size) 2.1 Mounting and Orientation With X06 Standalone H10 towards H1 header of X06 as in below picture. (X06 housing part # 53-0195) Extrusion Rail (part # 53-2060) Figure 5: X45B with X06 Ordering Information Model # 201-163 62-1486-A A03.5337-1510-A.20 62-1516-A 62-1449 62-1466 Rev. 1.0 Date 3/17/2017 Description X45B Control Board X45B S5bus 3-Wire Harness Eye5 IR Module with 20" cable 7-pin Pigtail for H7 8-pin Pigtail for H1 4-pin Pigtail for H8 8 X45B Controller Card Product Guide Specifications Power Operating Environment Mounting Dimensions 12VDC, 70 mA 40 to 150 °F (5 to 65 °C), 15-99% RH 3" (76 mm) mounting rail 3" L x 2 1/2" W x 1/2" D 76 mm L x 63 mm W x 12 mm D Approvals IC CE RoHS FCC ICES-003 Issue Class B Digital Apparatus emissions requirements (Canada) EN 61000-3-2:2006/A1:2009/A2:2009 Limits for harmonic current emissions EN 61000-3-3:2008 Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current up to and including 16A EN61000-6-3:2007/A1:2011 Emissions requirements for residential, commercial and light-industrial environments - Generic EN 61000-6-1:2007 Immunity for residential, commercial and lightindustrial environments - Generic EN 50581 Part 15 Document Revision History Revision First Issue V1.0 Date issued 03-Jan-2014 17-Aug-2017 Reason for change First Draft Reformat as per Honeywell Branding Guidelines The material in this document is for information purposes only. The content and the product it describes are subject to change without notice. Honeywell makes no representations or warranties with respect to this document. In no event shall Honeywell be liable for technical or editorial omissions or mistakes in this document, nor shall it be liable for any damages, direct or incidental, arising out of or related to the use of this document. No part of this document may be reproduced in any form or by any means without prior written permission from Honeywell. Copyright © 2017 by Honeywell International, Inc. All Rights Reserved. Rev.1.0 Date 3/17/2017 9 X45B Controller Card Product Guide Honeywell I 277 West Main Street I Niantic, CT 06357 I Phone: 1.860-739-4468 I www.inncom.com Rev. 1.0 Date 3/17/2017 10e456893 Adobe PDF Library 15.0