Note: To measure the airflow, the cross-sectional area of the tested air duct must be determined and input into the anemometer. Data hold To freeze a displayed reading, press the button.

Introduction AVM-06. A professional digital anemometer with stable performance, safety and reliability. It can measure air velocity, air volume, Widely used in wind energy.. View

PDF Ht625a风速计说明书 - 英文

Introduction AVM-06. A professional digital anemometer with stable performance, safety and reliability. It can measure air velocity, air volume, Widely used in wind energy, meteorology, industry, agriculture...


File Info : application/pdf, 9 Pages, 380.60KB

PDF preview unavailable. Download the PDF instead.

AVM-06
Introduction AVM-06
A professional digital anemometer with stable performance, safety and reliability. It can measure air velocity, air volume, Widely used in wind energy, meteorology, industry, agriculture, hydrology and water conservancy, environmental protection, highways, airports, etc.

Display

symbols description Data hold

symbols description

m/s

meter per second

MAX

Maximum value

Km/h

kilometers per hour

MIN

Minimum value

mil/h

Miles per hour

AVG

Average value

ft/m

Foot/minute

VEL

Air velocity

ft/s

Feet / sec

FLOW

Air flow

knots

nautical miles per hour

AREA

Air duct area setting m2

Square meter

CMM

Cubic meters per minute ft2

square foot

CMS

Cubic meters per second

Low battery

CFM

Cubic feet per minute

Automatic shutdown

Measurement Considerations
l Do not touch the fan blade with force. l Do not store or operate the instrument in areas with high
temperature or humidity. l In use, do not let the strong light directly shine on the fan, in order to
avoid measurement errors. l Avoid violent vibration l Remove the battery before storing the instrument for a long time
Operation
Air velocity measurement
1. Power the meter by pressing the power button, The "VEL" icon will appear in the display.
2. If the "VEL" icon disappears in the display, Press the FUNC button again until the "VEL" icon appear in the display.
3. Hand-held anemometer let the fan plane of anemometer be vertically aligned with the wind direction of the airflow.
4. View the measurement on the display Air duct area setting
1. Power the meter by pressing the power button, Press the SET button until the "AREA" icon appear in the

display 2. A data bit is flickering, indicating that this value can be
modified. 3. Press the REC button to set the scintillation digit to the
desired value 4. Press the UNIT button to select the next digit to be
adjusted. 5. After adjusting all the digits, it will jump to the adjusting
unit. The unit will flicker. Press REC button to change the unit. 6. After setting up, press the SET button to exit the setting state and return to the airflow measurement; the set data will be automatically saved. Airflow measurement
1. Power the meter by pressing the power button, The "VEL" icon will appear in the display
2. Press the FUNC button again, the "FLOW" icon will appear in the display
3. Hand-held anemometer let the fan plane of anemometer be vertically aligned with the wind direction of the airflow.
4. View the measurement on the display

Note: To measure the airflow, the cross-sectional area of the tested air duct must be determined and input into the anemometer. Data hold

To freeze a displayed reading, press the button. The "H" icon will appear and the most recent reading will appear in the display. Press the button to exit the mode and return to normal operation MAX/MIN/AVG function

1. Press the

button once to put the meter in

MAX/MIN/AVG mode. The meter will now display the highest

reading that occurs while the function is enabled. The "MAX"

icon will appear in the display.

2. Press the

button again to display the lowest reading

that occurs while the function is enabled. The "MIN" icon will

appear in the display.

3. Press the

button again to display the average reading

that occurs while the function is enabled. The "AVG" icon will

appear in the display.

4. Press

again to toggle between the MAX  MIN and

AVG readings.

5. To exit the MAX/MIN/AVG mode and return to the normal

real time display, press and hold the seconds).

button (2

Units of measure

Air velocity unit selection Press the UNIT button to select unit(m/skm/hmill/hft/m ft/sknots),when measuring air velocity. Airflow unit selection Press the UNIT button to select unit(CMS  CMM  CFM),when measuring airflow.

Meter Power and Automatic Power Off

1. Press the button to turn the meter on. 2. Press the button again to turn the meter off. 3. The meter has an automatic power off feature that conserves
battery energy. After 10 minutes the meter automatically shuts off.

4. To press and hold the

button to turn the meter on, the

auto power off function will be cancelled. And the icon disappears.

Specifications

Display

LCD, Max display 9999

Air velocity Sampling rate Sensor Beaufort Wind scale Max/Min/Avg Data hold Operating conditions Storage conditions Auto power off Power

0.40 ~ 30.00 m/s Approx. One reading per second Air velocity/flow sensor: angled vane arms with bearing 0~12 Record and view minimum, maximum, average Freeze reading Temperature:040°CHumidity:<80%RH Altitude :<2000m Temperature:-1050°CHumidity:<80%RH 10 minutes 3 x 1.5VAAA(LR03) batteries

Accuracy Specifications

The accuracy applies within one year after the calibration. Reference condition: the environment temperature 18°C to 28°C, the relative humidity is no more than 80%,

Air Velocity Measurements

Range

Resolution

Accuracy

m/s (meters per second)

0.40 ~ 30.00

0.01

±(2.0%+ 0.5m/s)

km/h (kilometers per hour)

1.40~108.0

0.01~0.1

±(2.0%+ 1.8km/h)

ft/s (feet per second)

1.30 ~ 98.50

0.01

±(2.0%+ 1.6ft/s)

ft/m (feet per minute)

78 .00~ 5900 0.01~1

±(2.0%+ 10ft/m)

knots (nautical miles per hour ) 0.80 ~ 58.30

0.01

±(2.0%+ 1.0knots)

mile/h(miles per hour)

0.90 ~ 67.10

0.01

±(2.0%+ 1.1mile/h)

Air Flow Measurements

Range

Resolution

Area

CFM (cubic feet per minute)

0-9999

0.01 to 1

0 - 9.999

CMM (cubic meters per minute) 0-9999

0.01 to 1

0 - 9.999

CMS (cubic meters per second) 0-9999

0.01 to 1

0 - 9.999

Maintenance
Battery Replacement When the battery voltage is low the ` ' symbol will appear on the
display. Replace the three (3) 1.5 `AAA' batteries by removing the rear
(center) battery compartment screw and accessing the battery compartment. Observe polarity when placing the batteries in the compartment. Ensure that the compartment cover is securely fastened when finished. Cleaning and storage
Caution To avoid damaging the instrument housing, do not use corrosive or solvent to clean the instrument.