Resources & | HVAC Controls & Building Automation | Building Controls Group
Relays | Current Sensors Power Supplies | Transformers Power Control | Enclosures | Accessories Wireless Devices | Energy Saving Devices TABLE OF CONTENTS 2016 RIB® Catalog NEW PRODUCTS RELAYS 10-15 AMP: 3 | 20-30 AMP: 23 | LATCHING: 44 | LOW INPUT / OPTOISOLATED: 47 | ALARM: 55 DRY CONTACT INPUT: 59 | NETWORK COMPATIBLE DEVICES: 65 | SPECIALTY PERIPHERAL CONTROLS: 83 CURRENT SENSORS SOLID & SPLIT CORE: 93 | TRANSDUCERS: 95 | T STYLE: 98 | TRACK MOUNT: 99 ENCLOSED, T STYLE & TRACK MOUNT COMBINATIONS: 100 POWER SUPPLIES AC: 108 | DC: 125 TRANSFORMERS U.S. MANUFACTURED: 130 POWER CONTROL POWER CONTROL CENTERS: 134 | TRACK MOUNT CIRCUIT BREAKER SWITCHES: 134 PREPACKAGED SWITCHES: 135 | UPS INTERFACE DEVICES: 136 ENCLOSURES PLASTIC: 141 | SMALL METAL: 142 | MEDIUM METAL: 143 | LARGE METAL: 144 ACCESSORIES SUB-PANELS: 148 | MOUNTING SUPPLIES: 152 | REPLACEMENT PARTS: 153 WIRELESS DEVICES WIRELESS CONTROL RELAYS: 156 | WIRELESS TRANSMITTERS: 157 ENERGY SAVING DEVICES HALF-LIGHT® BALLAST CONTROLLERS: 160 INDEX 2 3 91 107 129 133 141 147 155 159 163 (800) 888-5538 | www.functionaldevices.com 1 NEW PRODUCTS 2016 NEW PRODUCTS EXPAND YOUR NETWORK EXPAND YOUR CONTROL Wi-Fi RIBTM Prepackaged Enclosure, Power Supply, and Sub-Panel Great for mounting a controller along with peripheral devices. Designed to provide everything you need to mount controllers in one package. Convenience and time savings are essential when you're in the field, and Functional Devices is known for providing both! PAGES 80 & 81 PAGES 114 & 115 Analog Output Network Device Designed for I/O Applications Valve · Actuator · Damper · VFD · Pump Fan Binary Output Binary Input Analog Output PAGE 155 PAGE 76 Temp Input 2 Functional Devices, Inc. | American Made. American Owned. RELAYS PILOT RELAYS: 1015 AMPS Enclosed | T Style | Track Mount Prepackaged For Convenience Great Time Saver · LED indicator · 10-15 Amp models · Multi-voltage coil input · Pre-wired · Several different contact ratings · Track mount panel style · True override switch on load side of relay · Time delay models · High/low voltage separation Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). ENCLOSED PILOT RELAYS COIL VOLTAGE MODEL # RIBU1C · RIBH1C · RIBU2C · RIBH2C · RIBL3C · RIBL4C · RIBU1S · RIBH1S · RIBU1SM-250 · RIBH1SM-250 · RIB2401D · RIB2402D · RIBU1SC · RIBH1SC · RIBL1C-DC · RIB2421C · RIBD2421C · RIBU2SC · RIBU2S2 · AC/DC 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 24 24 10-30 10-30 10-30 1 24 24 10-30 10-30 AC 120 208-277 120 208-277 120 208-277 120 208-277 120 208-277 120 208-277 120-277 120-277 120 120 RELAYS 1 1 2 2 3 4 1 1 1 1 1 1 1 1 1 1 1 2 2 CONTACTS SPDT SPDT 2 SPDT 2 SPDT 3 SPST 3 SPST, 1 SPDT SPST SPST SPST SPST DPDT DPDT SPDT SPDT SPDT SPDT SPDT 1 SPST, 1 SPDT 2 SPST OVERRIDE SWITCH 1 1 1+monitor 1+monitor 2 3 2 3 1 2 NOTES 2 SPEC PAGE 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 9 10 10 T STYLE PILOT RELAYS COIL VOLTAGE MODEL # RIBTU1C · RIBTH1C · RIBTU2C · RIBTH2C · RIBU1CW · RIBH1CW · RIBTU1S · RIBTH1S · RIBTU1SC · RIBTH1SC · RIBT2401D · AC/DC 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 24 AC 120 208-277 120 208-277 120 208-277 120 208-277 120 208-277 120 RELAYS 1 1 2 2 1 1 1 1 1 1 1 CONTACTS SPDT SPDT 2 SPDT 2 SPDT SPDT SPDT SPST SPST SPDT SPDT DPDT OVERRIDE SWITCH 1 1 2 3 2 3 NOTES SPEC PAGE 11 11 11 11 12 12 12 12 13 13 13 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 1 = DC Only 2 = Time Delay 3 = SPDT with override requires 2 switches (800) 888-5538 | www.functionaldevices.com 3 RELAYS TRACK MOUNT PILOT RELAYS COIL VOLTAGE MODEL # RIBAN12C · 1 RIBAN24C · 1 RIBM12C · RIBM12S · RIBM24C · RIBM24S · RIBM2401D · RIBM2402D · RIBMU1C · RIBMU1S · RIBMH1C · RIBMH1S · RIBMU2C · RIBMH2C · RIBMU1SM-250 · RIBMH1SM-250 · RIBMU1SC · RIBMH1SC · RIBMN12C · RIBMN12S · RIBMN24C · RIBMN24S · RIBMN24S-J · RIBMN24C-4T · RIBMN24S-4T · RIBMN2401D · RIBMNU1C · RIBMNU1S · RIBMNH1C · RIBMNH1S · AC/DC 12 24 12 12 24 24 24 24 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 12 12 24 24 24 24 24 24 10-30 10-30 10-30 10-30 AC 120 208-277 120 120 208-277 208-277 120 208-277 120 208-277 120 208-277 120 120 120 208-277 208-277 RELAYS 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 4 4 1 1 1 1 1 CONTACTS SPDT SPDT SPDT SPST SPDT SPST DPDT DPDT SPDT SPST SPDT SPST 2 SPDT 2 SPDT SPST SPST SPDT SPDT SPDT SPST SPDT SPST SPST 4 SPDT 4 SPST DPDT SPDT SPST SPDT SPST OVERRIDE SWITCH 1 1 1 1 1+monitor 1+monitor 2 2 2 2 1 1 1 4 1 1 NOTES SPEC PAGE 14 14 15 15 15 15 16 16 16 17 16 17 17 17 18 18 18 18 19 19 19 19 20 20 20 21 21 22 21 22 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 1 = UL Listed : UL508 only ; USA & Canada 2 = SPDT with override requires 2 switches 10 AMP PILOT CONTROL RELAYS RIBU1C Enclosed Relay 10 Amp SPDT with 10-30 Vac/dc/120 Vac Coil RIBH1C Enclosed Relay 10 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Made in USA Meets "Buy American" of ARRA 2009 RIBU1C-RD RIBH1C-RD · Red housing RIBU1C-N4 RIBH1C-N4 · NEMA 4X housing, UL508 only SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1C) 39 mA @ 208-277 Vac (RIBH1C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 4 Functional Devices, Inc. | American Made. American Owned. RELAYS 10 AMP PILOT CONTROL RELAYS RIBU2C Enclosed Relays 10 Amp 2 SPDT with 10-30 Vac/dc/120 Vac Coil RIBH2C Enclosed Relays 10 Amp 2 SPDT with 10-30 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Wht/Red 120 Vac Gry/Wht 10-30 Vac/dc Wht/Prp Comm Gry N/C Prp Comm Brn N/O Wht/Org 208-277 Vac Gry/Wht 10-30 Vac/dc Wht/Prp Comm Gry N/C Prp Comm Brn N/O SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .75 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU2C) 39 mA @ 208-277 Vac (RIBH2C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 10 AMP PILOT CONTROL RELAYS RIBL3C Enclosed Relays 10 Amp 3 SPST-N/O with 10-30 Vac/dc Coil RIBL4C Enclosed Relays 10 Amp 3 SPST-N/O + 1 SPDT with 10-30 Vac/dc Coil Wht/Blk RELAY 1 Blk RELAY 1 Blk Wht/Blu RELAY 2 Blu RELAY 2 Blu Wht/Yel RELAY 3 Wht/Red COMM Yel RELAY 3 Yel · All relay coils use the same common · All relay coils 10-30 Vac/dc Wht/Blk RELAY 1 Wht/Blu RELAY 2 Wht/Yel RELAY 3 Wht/Brn RELAY 4 Wht/Red COMM · All relay coils use the same common · All relay coils 10-30 Vac/dc Blk RELAY 1 Blk Blu RELAY 2 Blu Yel RELAY 3 Yel Gry RELAY 4 Prp Brn Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: Three (3) SPST Continuous Duty Coil (RIBL3C) Contact Ratings: Coil Current: Three (3) SPST + One (1) SPDT Continuous 10 Amp Resistive @ 277 Vac 33 mA @ 10 Vac 13 mA @ 10 Vdc Duty Coil (RIBL4C) 10 Amp Resistive @ 28 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc Expected Relay Life: 10 million cycles minimum mechanical 480 VA Pilot Duty @ 240-277 Vac 46 mA @ 24 Vac 18 mA @ 24 Vdc Operating Temperature: -30 to 140° F 480 VA Ballast @ 277 Vac 55 mA @ 30 Vac 20 mA @ 30 Vdc Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) Coil Voltage Input: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Notes: · Order Normally Closed by adding "-NC" to end of model number Override Switch: No (800) 888-5538 | www.functionaldevices.com 5 10 AMP PILOT CONTROL RELAYS RIBU1S Enclosed Relay 10 Amp SPST-N/O + Override with 10-30 Vac/dc/120 Vac Coil RIBH1S Enclosed Relay 10 Amp SPST-N/O + Override with 10-30 Vac/dc/208-277 Vac Coil RELAYS Wht/Blk 120 Vac Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc CLOSED OPEN AUTO Wht/Blu 10-30 Vac/dc CLOSED OPEN AUTO Wht/Yel Wht/Yel Comm Org Comm Org Org Org Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1S) 39 mA @ 208-277 Vac (RIBH1S) Notes: · Order Normally Closed by adding "-NC" to end of model number 10 AMP PILOT CONTROL RELAYS RIBU1SM-250 Enclosed Relay 10 Amp SPST-N/O + Override + Monitor with 10-30 Vac/dc/120 Vac Coil RIBH1SM-250 Enclosed Relay 10 Amp SPST-N/O + Override + Monitor with 10-30 Vac/dc/208-277 Vac Coil AUTO COMM CLOSED AUTO COMM CLOSED Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO CLOSED OPEN AUTO Brn Prp Gry POLE 2 Org Org POLE 1 Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO CLOSED OPEN AUTO Brn Prp Gry POLE 2 Org Org POLE 1 Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes + Monitor Contact Ratings: 10 Amp Resistive @ 120/250 Vac 345 VA Pilot Duty @ 120/240 Vac 211 VA Pilot Duty @ 120/240 Vac 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) Coil Current: 55 mA @ 30 Vac 28 mA @ 120 Vac (RIBU1SM-250) 39 mA @ 208-277 Vac (RIBH1SM-250) 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1SM-250) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1SM-250) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: · Second pole of override switch can be connected to digital-in of controller to report position of override switch · Rating of second pole is 250 Vac max and 5 Amp max · Order Normally Closed by adding "-NC" to end of model number 6 Functional Devices, Inc. | American Made. American Owned. RELAYS 10 AMP PILOT CONTROL RELAYS RIB2401D Enclosed Relay 10 Amp DPDT with 24 Vac/dc/120 Vac Coil RIB2402D Enclosed Relay 10 Amp DPDT with 24 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Made in USA Meets "Buy American" of ARRA 2009 RIB2401D-RD RIB2402D-RD · Red housing RIB2401D-N4 RIB2402D-N4 · NEMA 4X housing, UL508 only SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max Coil Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 30 Vdc 31 mA @ 120 Vac (RIB2401D) 36 mA @ 208-277 Vac (RIB2402D) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401D) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402D) Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc 10 AMP PILOT CONTROL RELAYS RIBU1SC Enclosed Relay 10 Amp SPDT + Override with 10-30 Vac/dc/120 Vac Coil RIBH1SC Enclosed Relay 10 Amp SPDT + Override with 10-30 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2) Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1SC) 39 mA @ 208-277 Vac (RIBH1SC) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc (800) 888-5538 | www.functionaldevices.com 7 RELAYS 10 AMP PILOT CONTROL RELAYS RIBL1C-DC Enclosed Relay 10 Amp SPDT with 10-30 Vdc Limited Inrush Coil Wht/Blu 10-30 Vdc Wht/Yel Comm Blu N/C Yel Comm Org N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No RIBL1C-DC-RD · Red housing RIBL1C-DC-N4 · NEMA 4X housing, UL508 only Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vdc Drop Out = 2.8 Vdc Pull In = 10 Vdc 10 AMP PILOT CONTROL RELAYS RIB2421C Enclosed Relay 10 Amp SPDT with 24 Vac/dc/120-277 Vac Coil Wht/Brn 120-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O RIB2421C-RD · Red housing RIB2421C-N4 · NEMA 4X housing, UL508 only GREAT SERVICE TRUCK RELAY ONE RELAY COVERS MOST APPLICATIONS Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 66 mA @ 24 Vac 38 mA @ 24 Vdc 40 mA @ 120-277 Vac Coil Voltage Input: 24 Vac/dc ; 120-277 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 8 Functional Devices, Inc. | American Made. American Owned. RELAYS 10 AMP PILOT CONTROL RELAY RIBD2421C Enclosed Time Delay Relay 10 Amp SPDT with 24 Vac/dc/120-277 Vac Coil Wht/Brn Blu 120-277 Vac N/C Wht/Blu 24 Vac/dc Yel Comm Wht/Yel Org Comm N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms after time delay Relay Status: RED LED On = Activated Time Delay Status: PINK LED FLASHING = Timing Timing Mode: Delay On Make (N/O) Timing Range: 6 seconds - 20 minutes Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5% Timing Repeatability: +1% Temperature Timing Variance: +1% Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Input Current: 66 mA @ 24 Vac 38 mA @ 24 Vdc 40 mA @ 120-277 Vac Coil Voltage Input: 24 Vac/dc ; 120-277 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Timing Adjustment C BD AE Range Selection 1234 Only Close 1 Switch Depressed for closed Depressed for open Switch Ranges 6s-20s 22s-1min15s 1min30s-5min 6min-20min Close Dip Switch 1 2 3 4 TIMING TABLE Potentiometer Setting A B C D 6s 9s 13s 16s 22s 36s 50s 1min4s 1min30s 2min10s 3min20s 4min16s 6min 9min 13min20s 17min20s E 20s 1min15s 5min 20min Coil Time Delay N/O N/C Time Delay Timing Diagram Time Delay Time Delay Time Delay Time Delay Time Delay Application Load 2 stays on selected amount of time after Load 1 goes off. Load 1 (Thermostat Controlled Heater, for example) In this example, voltage can be any voltage from 120-277 Vac. Blu Wht/Yel Neutral Blu Load 2 (Circulating Fan, for example) Yel RIB® Select RIB® with coil input appropriate to sense Load 1. Wht/Brn Yel RIBD2421C (800) 888-5538 | www.functionaldevices.com 9 RELAYS 10 AMP PILOT CONTROL RELAY RIBU2SC Enclosed Relays 10 Amp SPST-N/O + Override + 1 SPDT with 10-30 Vac/dc/120 Vac Coil Wht/Red Gry 120 Vac N/C Gry/Wht 10-30 Vac/dc Prp Comm Wht/Prp Brn Comm N/O Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO Org Org Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST + One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .75 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 28 mA @ 120 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number 10 AMP PILOT CONTROL RELAY RIBU2S2 Enclosed Relays 10 Amp 2 SPST-N/O + 2 Overrides with 10-30 Vac/dc/120 Vac Coil Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc CLOSED OPEN AUTO Wht/Yel Org Comm Org Wht/Red 120 Vac Gry/Wht 10-30 Vac/dc CLOSED OPEN AUTO Wht/Prp Brn Comm Brn SPECIFICATIONS # Relays & Contact Type: Two (2) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2) Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 28 mA @ 120 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc 10 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number RELAYS 10 AMP PILOT CONTROL RELAYS RIBTU1C Enclosed Relay Hi/Low Separation 10 Amp SPDT with 10-30 Vac/dc/120 Vac Coil RIBTH1C Enclosed Relay Hi/Low Separation 10 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac Blu - N/C Yel - Comm Org - N/O Comm 10-30 Vac/dc 208-277 Vac Blu - N/C Yel - Comm Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1C) 39 mA @ 208-277 Vac (RIBTH1C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 10 AMP PILOT CONTROL RELAYS RIBTU2C Enclosed Relays Hi/Low Separation 10 Amp 2 SPDT with 10-30 Vac/dc/120 Vac Coil RIBTH2C Enclosed Relays Hi/Low Separation 10 Amp 2 SPDT with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac Comm 10-30 Vac/dc 120 Vac Comm 10-30 Vac/dc 208-277 Vac Comm 10-30 Vac/dc 208-277 Vac Blu - N/C Yel - Comm Org - N/O Brn - N/O Prp - Comm Gry - N/C Blu - N/C Yel - Comm Org - N/O Brn - N/O Prp - Comm Gry - N/C Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU2C) 39 mA @ 208-277 Vac (RIBTH2C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc (800) 888-5538 | www.functionaldevices.com 11 15 AMP PILOT CONTROL RELAYS RIBU1CW Enclosed Relay Hi/Low Separation 15 Amp SPDT with 10-30 Vac/dc/120 Vac Coil RIBH1CW Enclosed Relay Hi/Low Separation 15 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil RELAYS Comm 10-30 Vac/dc 120 Vac N/O N/C Comm Comm 10-30 Vac/dc 208-277 Vac SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No N/O N/C Comm Contact Ratings: 15 Amp Resistive @ 150 Vac, 28Vdc 15 Amp Inductive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1CW) 39 mA @ 208-277 Vac (RIBH1CW) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1CW) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1CW) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 10 AMP PILOT CONTROL RELAYS RIBTU1S Enclosed Relay Hi/Low Separation 10 Amp SPST + Override with 10-30 Vac/dc/ 120 Vac Coil RIBTH1S Enclosed Relay Hi/Low Separation 10 Amp SPST + Override with 10-30 Vac/dc/ 208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac Selectable Jumper Wire Org CLOSED Org OPEN AUTO Comm 10-30 Vac/dc 208-277 Vac Selectable Jumper Wire Org CLOSED Org OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Notes: · Normally Open or Normally Closed selected by yellow jumper wire Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1S) 39 mA @ 208-277 Vac (RIBTH1S) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 12 Functional Devices, Inc. | American Made. American Owned. 10 AMP PILOT CONTROL RELAYS RIBTU1SC Enclosed Relay Hi/Low Separation 10 Amp SPDT + Override with 10-30 Vac/dc/ 120 Vac Coil Comm 10-30 Vac/dc Blu N/C N/C - CLOSED OPEN Org N/O N/O - CLOSED RIBTH1SC Enclosed Relay Hi/Low Separation 10 Amp SPDT + Override with 10-30 Vac/dc/ 208-277 Vac Coil Comm 10-30 Vac/dc Blu N/C N/C - CLOSED OPEN Org N/O N/O - CLOSED 120 Vac MANUAL AUTO Yel Comm 208-277 Vac MANUAL AUTO Yel Comm Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2) Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1SC) 39 mA @ 208-277 Vac (RIBTH1SC) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 10 AMP PILOT CONTROL RELAY RIBT2401D Enclosed Relay Hi/Low Separation 10 Amp DPDT with 24 Vac/dc/120 Vac Coil 120 Vac 24 Vac/dc Comm Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max (800) 888-5538 | www.functionaldevices.com Coil Current: 24 mA @ 18 Vac 32 mA @ 24 Vac 40 mA @ 30 Vac 31 mA @ 120 Vac 20 mA @ 20 Vdc 24 mA @ 24 Vdc 36 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc 13 RELAYS 10 AMP TRACK MOUNT CONTROL RELAYS RIBAN24C Track Mount Relay 10 Amp SPDT with 24 Vac/dc Coil RIBAN12C Track Mount Relay 10 Amp SPDT with 12 Vac/dc Coil 24 Vac/dc 12 Vac/dc N/O N/O Comm Comm N/C N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.025 x 2.750 x 2.850 Terminals: Removable, Accepts 22-16 AWG copper wires Mounting: A: 2.750 Track Mount, See MT212 Series on page 152. MT212 Mounting Track Sold Separately. B: 35mm x 7.5mm symmetrical DIN rail EN50022 C: Screw Mount, See DS80625 on page 153. DS80625 Self-Tapping Drill Screws Sold Separately. D: Current Sensor Mount, See RIBXG Series on page 94 or RIBXK Series on page 93. Current Sensors Sold Separately. Approvals: UL Listed, UL508, C-UL, CE, RoHS Gold Flash: No Override Switch: No RELAY MOUNTING OPTIONS A & B Mounting Option A: 2.75" Track Mount MT212 Series K G Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Voltage Input (RIBAN24C): 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Coil Voltage Input (RIBAN12C): 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Made in USA Meets "Buy American" of ARRA 2009 REMOVABLE TERMINALS Coil Current (RIBAN24C): 26 mA @ 20 Vac 31 mA @ 24 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Current (RIBAN12C): 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc Notes: · Set of replacement terminals available. Order model number: TS-AN Mounting Option B: K G 35mm x 7.5mm symmetrical DIN rail EN50022 CURRENT SENSOR MOUNTING OPTION D K RIBXK Series Mounting Tab G RIBXG Series Mounting Tab 1. Slide current sensor onto corresponding mounting tab. 2. Snap into place. 3. Depress tab to remove current sensor. 14 Functional Devices, Inc. | American Made. American Owned. RELAYS 15 AMP TRACK MOUNT CONTROL RELAYS RIBM12C 4.00 Track Mount Relay 15 Amp SPDT with 12 Vac/dc Coil RIBM12S 4.00 Track Mount Relay 15 Amp SPST + Override with 12 Vac/dc Coil Comm 12 Vac/dc N/C Comm N/O Comm 12 Vac/dc AUTO OPEN CLOSED Comm N/O or N/C Selectable Jumpers (must cut one only) SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBM12C) One (1) SPST Continuous Duty Coil (RIBM12S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.250 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBM12C) Yes (RIBM12S) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Made in USA Meets "Buy American" of ARRA 2009 Cut for N/O Cut for N/C Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 36 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBM12S) 15 AMP TRACK MOUNT CONTROL RELAYS RIBM24C 4.00 Track Mount Relay 15 Amp SPDT with 24 Vac/dc Coil RIBM24S 4.00 Track Mount Relay 15 Amp SPST + Override with 24 Vac/dc Coil Comm N/C Comm AUTO OPEN CLOSED Comm Made in USA Meets "Buy American" of ARRA 2009 24 Vac/dc Comm N/O SPECIFICATIONS 24 Vac/dc N/O or N/C Selectable Jumpers (must cut one only) Cut for N/O Cut for N/C # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBM24C) One (1) SPST Continuous Duty Coil (RIBM24S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.250 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBM24C) Yes (RIBM24S) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBM24S) (800) 888-5538 | www.functionaldevices.com 15 RELAYS 10 AMP TRACK MOUNT CONTROL RELAYS RIBM2401D 4.00 Track Mount Relay 10 Amp DPDT with 24 Vac/dc/120 Vac Coil RIBM2402D 4.00 Track Mount Relay 10 Amp DPDT with 24 Vac/dc/208-277 Vac Coil 120 Vac 24 Vac/dc Comm N/O Comm N/C N/O Comm N/C 208-277 Vac 24 Vac/dc Comm N/O Comm N/C N/O Comm N/C Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 1.700 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max Coil Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 30 Vdc 31 mA @ 120 Vac (RIBM2401D) 36 mA @ 208-277 Vac (RIBM2402D) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401D) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402D) Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc 15 AMP TRACK MOUNT CONTROL RELAYS RIBMU1C 4.00 Track Mount Relay 15 Amp SPDT with 10-30 Vac/dc/120 Vac Coil RIBMH1C 4.00 Track Mount Relay 15 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac N/C Comm N/O Comm 10-30 Vac/dc 208-277 Vac N/C Comm N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.250 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 15 Amp Inductive @ 150 Vac 15 Amp Resistive @ 150 Vac, 28 Vdc 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1C) 39 mA @ 208-277 Vac (RIBMH1C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 16 Functional Devices, Inc. | American Made. American Owned. 15 AMP TRACK MOUNT CONTROL RELAYS RIBMU1S 4.00 Track Mount Relay 15 Amp SPST-N/O + Override with 10-30 Vac/dc/120 Vac Coil RIBMH1S 4.00 Track Mount Relay 15 Amp SPST-N/O + Override with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac AUTO OPEN CLOSED Comm 10-30 Vac/dc 208-277 Vac AUTO OPEN CLOSED Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.275 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: Yes Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1S) 39 mA @ 208-277 Vac (RIBMH1S) Notes: · Order Normally Closed by adding "-NC" to end of model number 15 AMP TRACK MOUNT CONTROL RELAYS RIBMU2C 4.00 Track Mount Relays 15 Amp 2 SPDT with 10-30 Vac/dc/120 Vac Coil RIBMH2C 4.00 Track Mount Relays 15 Amp 2 SPDT with 10-30 Vac/dc/208-277 Vac Coil Comm N/C Comm N/C 10-30 Vac/dc Comm 10-30 Vac/dc Comm 120 Vac N/O Comm N/C 208-277 Vac N/O Comm N/C 10-30 Vac/dc Comm 10-30 Vac/dc Comm 120 Vac N/O 208-277 Vac N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.450 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 15 Amp Inductive @ 150 Vac 15 Amp Resistive @ 150 Vac, 28 Vdc 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) (800) 888-5538 | www.functionaldevices.com Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU2C) 39 mA @ 208-277 Vac (RIBMH2C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 17 RELAYS 15 AMP TRACK MOUNT CONTROL RELAYS RIBMU1SM-250 4.00 Track Mount Relay 15 Amp SPST + Override + Monitor with 10-30 Vac/dc/ 120 Vac Coil RIBMH1SM-250 4.00 Track Mount Relay 15 Amp SPST + Override + Monitor with 10-30 Vac/dc/ 208-277 Vac Coil Closed Comm Auto Comm CLOSED OPEN AUTO Selectable Jumper Wire Closed Comm Auto Comm CLOSED OPEN AUTO Selectable Jumper Wire 10-30 Vac/dc 120 Vac CLOSED OPEN AUTO 10-30 Vac/dc 208-277 Vac CLOSED OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.000 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: Yes + Monitor Contact Ratings: 15 Amp Resistive @ 125 Vac 10 Amp Resistive @ 250 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 1/3 HP for N/O @ 120-240 Vac 1/6 HP for N/C @ 120-240 Vac Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1SM-250) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1SM-250) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1SM-250) 39 mA @ 208-277 Vac (RIBMH1SM-250) Notes: · Normally Open or Normally Closed selected by yellow jumper wire · Second pole of override switch can be connected to digital-in of controller to report position of override switch · Rating of second pole is 50 Vac/dc, 0.25 Amp max 15 AMP TRACK MOUNT CONTROL RELAYS RIBMU1SC 4.00 Track Mount Relay 15 Amp SPDT + Override with 10-30 Vac/dc/120 Vac Coil RIBMH1SC 4.00 Track Mount Relay 15 Amp SPDT + Override with 10-30 Vac/dc/208-277 Vac Coil Comm Comm Made in USA Meets "Buy American" of ARRA 2009 10-30 Vac/dc 120 Vac AUTO MANUAL N/O CLOSED N/C CLOSED OPEN Comm N/C N/O 10-30 Vac/dc 208-277 Vac AUTO MANUAL N/O CLOSED N/C CLOSED OPEN Comm N/C N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.500 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: Yes (2) Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1SC) 39 mA @ 208-277 Vac (RIBMH1SC) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 18 Functional Devices, Inc. | American Made. American Owned. 15 AMP TRACK MOUNT CONTROL RELAYS RIBMN12C 2.75 Track Mount Relay 15 Amp SPDT with 12 Vac/dc Coil RIBMN12S 2.75 Track Mount Relay 15 Amp SPST + Override with 12 Vac/dc Coil Made in USA Meets "Buy American" of ARRA 2009 RELAYS Comm 12 Vac/dc N/C Comm N/O Comm 12 Vac/dc AUTO OPEN CLOSED Comm N/O or N/C Selectable Jumpers (must cut one only) SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN12C) One (1) SPST Continuous Duty Coil (RIBMN12S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.100 x 2.750 x 1.750 (RIBMN12C) 1.250 x 2.750 x 1.750(RIBMN12S) Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN12C) Yes (RIBMN12S) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty 15 AMP TRACK MOUNT CONTROL RELAYS RIBMN24C 2.75 Track Mount Relay 15 Amp SPDT with 24 Vac/dc Coil RIBMN24S 2.75 Track Mount Relay 15 Amp SPST + Override with 24 Vac/dc Coil Cut for N/O Cut for N/C Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN12S) Made in USA Meets "Buy American" of ARRA 2009 Comm N/C Comm AUTO OPEN CLOSED Comm 24 Vac/dc Comm N/O 24 Vac/dc N/O or N/C Selectable Jumpers (must cut one only) Cut for N/O Cut for N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN24C) One (1) SPST Continuous Duty Coil (RIBMN24S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions (RIBMN24C): 1.100 x 2.750 x 0.750 (without track) 1.100 x 2.750 x 1.250 (including track) Dimensions (RIBMN24S): 1.250 x 2.750 x 1.000 (without track) 1.250 x 2.750 x 1.500 (including track) Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN24C), Yes (RIBMN24S) (800) 888-5538 Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN24S) | www.functionaldevices.com 19 RELAYS 15 AMP TRACK MOUNT CONTROL RELAY RIBMN24S-J 2.75 Track Mount Relay 15 Amp SPST + Override with 24 Vac/dc Coil and Jumper Selectable Output Comm AUTO OPEN CLOSED 24 Vac/dc Selectable Jumper Wire SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.250 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Normally Open or Normally Closed selected by yellow jumper wire. 15 AMP TRACK MOUNT CONTROL RELAYS RIBMN24C-4T Four 2.75 Track Mount Relays 15 Amp SPDT with 24 Vac/dc Coil and 2.75 x 6.00 Mounting Track RIBMN24S-4T Four 2.75 Track Mount Relays 15 Amp SPST + Override with 24 Vac/dc Coil and 2.75 x 6.00 Mounting Track Comm 24 Vac/dc N/C Comm N/O Comm 24 Vac/dc AUTO OPEN CLOSED Comm N/O or N/C Selectable Jumpers (must cut one only) Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: Four (4) SPDT Continuous Duty Coils (RIBMN24C-4T) Four (4) SPST Continuous Duty Coils (RIBMN24S-4T) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 6.000 x 2.750 x 1.150 (RIBMN24C-4T) 6.000 x 2.750 x 1.500 (RIBMN24S-4T) Track Mount: 2.750 x 6.000 ; MT212-6 Mounting Track Included Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN24C-4T) Yes (RIBMN24S-4T) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN24S-4T) 20 Functional Devices, Inc. | American Made. American Owned. RELAYS 10 AMP TRACK MOUNT CONTROL RELAY RIBMN2401D 2.75 Track Mount Relay 10 Amp DPDT with 24 Vac/dc/120 Vac Coil 120 Vac 24 Vac/dc Comm N/O Comm N/C N/O Comm N/C SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 1.700 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max Coil Current: 36 mA @ 30Vdc 24 mA @ 18 Vac 32 mA @ 24 Vac 40 mA @ 30 Vac 31 mA @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc 15 AMP TRACK MOUNT CONTROL RELAYS RIBMNU1C 2.75 Track Mount Relay 15 Amp SPDT with 10-30 Vac/dc/120 Vac Coil RIBMNH1C 2.75 Track Mount Relay 15 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac N/C Comm N/O Comm 10-30 Vac/dc 208-277 Vac N/C Comm N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.700 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 15 Amp Resistive @ 150 Vac, 28Vdc 15 Amp Inductive @ 150 Vac 10 Amp Resistive @ 120-277 Vac, 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMNU1C) 39 mA @ 208-277 Vac (RIBMNH1C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMNU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMNH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc (800) 888-5538 | www.functionaldevices.com 21 RELAYS 15 AMP TRACK MOUNT CONTROL RELAYS RIBMNU1S 2.75 Track Mount Relay 15 Amp SPST + Override with 10-30 Vac/dc/120 Vac Coil RIBMNH1S 2.75 Track Mount Relay 15 Amp SPST + Override with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac AUTO OPEN CLOSED Selectable Jumper Wire Comm 10-30 Vac/dc 208-277 Vac AUTO OPEN CLOSED Selectable Jumper Wire Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.500 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: Yes Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMNU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMNH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMNU1S) 39 mA @ 208-277 Vac (RIBMNH1S) Notes: · Normally Open or Normally Closed selected by yellow jumper wire 22 Functional Devices, Inc. | American Made. American Owned. POWER RELAYS: 2030 AMPS Enclosed | T Style | Track Mount Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). RELAYS ENCLOSED POWER RELAYS COIL VOLTAGE MODEL # RIB2401B AC/DC · 24 RIB2402B · 24 RIB2401SB · 24 RIB2402SB · 24 RIB2421B · 24 RIB2421SB · 24 RIB01P · RIB02P · RIB347P · RIB04P · RIB2401SBC · 24 RIB2402SBC · 24 RIB243P · 3 24 RIB013P · RIB023P · RIB043P · RIB24Z · 24 RIB12P · 12 RIB12P30 · 12 RIB24P · 24 RIB24P30 · 24 RIB01P30 · RIB01P30-S · RIB02P30 · AC 120 208-277 120 208-277 120/208-277 120/208-277 120 208-277 347 480 120 208-277 120 208-277 480 120 120 208-277 T STYLE POWER RELAYS COIL VOLTAGE MODEL # RIBT24B · RIBT2401B · RIBTD2401B · RIBT2402B · RIBT242B · RIBT243B · 3 RIBT24SB · RIBT2401SB · RIBT2402SB · RIBT2401SBC · RIBT2402SBC · RIBT24P · RIBT24Z · RIBT243P · 3 AC/DC 24 24 24 24 24 24 24 24 24 24 24 24 24 24 AC 120 120 208-277 120 208-277 120 208-277 RELAYS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CONTACTS SPDT SPDT SPST SPST SPDT SPST DPDT DPDT DPDT DPDT SPDT SPDT 3PST 3PST 3PST 3PST 1 SPST N/O, 1 SPST N/C DPDT DPDT DPDT DPDT DPST DPST DPST OVERRIDE SWITCH 1 1 1 2 1 2 1 1 NOTES NEW SPEC PAGE 24 24 25 25 25 25 26 27 27 28 26 26 28 29 29 30 30 31 31 31 31 32 32 32 RELAYS 1 1 1 1 2 3 1 1 1 1 1 1 1 1 CONTACTS SPDT SPDT SPDT SPDT 2 SPDT 2 SPST, 1 SPDT SPST SPST SPST SPDT SPDT DPDT 1 SPST N/O, 1 SPST N/C 3PST OVERRIDE SWITCH 1 1 1 2 1 2 1 NOTES 2 SPEC PAGE 33 33 35 33 36 36 33 34 34 34 34 36 37 37 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 3 = UL Listed : UL916 Energy Management ; USA & Canada 1 = SPDT with override requires 2 switches (800) 888-5538 | www.functionaldevices.com 2 = Time Delay 23 RELAYS TRACK MOUNT POWER RELAYS COIL VOLTAGE MODEL # AC/DC AC RIBM2401B · 24 120 RIBM2402B · 24 208-277 RIBM2401SB · 24 120 RIBM2402SB · 24 208-277 RIBM2401SBC · 24 120 RIBM2402SBC · 24 208-277 RIBM24ZN 24 RIBM24ZL · 24 RIBMN24ZL · 24 RIBM243PN 24 RIBM013PN 120 RIBM023PN 208-277 RIBM043PN 480 RIBM043PN-HD 480 RELAYS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada = UL Component Recognized : UL916 Energy Management; USA & Canada CONTACTS SPDT SPDT SPST SPST SPDT SPDT DPDT DPST DPST 3PDT 3PDT 3PDT 3PDT 3PDT OVERRIDE SWITCH 1 1 2 1 2 1 NOTES 1 = SPDT with override requires 2 switches SPEC PAGE 38 38 38 38 39 39 39 40 40 41 41 42 42 43 20 AMP POWER CONTROL RELAYS RIB2401B Enclosed Relay 20 Amp SPDT with 24 Vac/dc/120 Vac Coil RIB2402B Enclosed Relay 20 Amp SPDT with 24 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIB2401B) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIB2402B) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 24 Functional Devices, Inc. | American Made. American Owned. RELAYS 20 AMP POWER CONTROL RELAYS RIB2401SB Enclosed Relay 20 Amp SPST-N/O + Override with 24 Vac/dc/120 Vac Coil RIB2402SB Enclosed Relay 20 Amp SPST-N/O + Override with 24 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc CLOSED OPEN AUTO Wht/Blu 24 Vac/dc CLOSED OPEN AUTO Wht/Yel Wht/Yel Comm Org Comm Org Org Org SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, UL508, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401SB) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402SB) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIB2401SB) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIB2402SB) Notes: · Order Normally Closed by adding "-NC" to end of model number 20 AMP POWER CONTROL RELAYS RIB2421B Enclosed Relay 20 Amp with 24 Vac/dc/208-277 Vac/120 Vac Coil RIB2421SB Enclosed Relay 20 Amp + Override with 24 Vac/dc/208-277 Vac/120 Vac Coil Made in USA Meets "Buy American" of ARRA 2009 Wht/Brn 208-277 Vac Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Wht/Brn 208-277 Vac Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO Org Org GREAT SERVICE TRUCK RELAY ONE RELAY COVERS MOST APPLICATIONS SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIB2421B) One (1) SPST Continuous Duty Coil (RIB2421SB) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIB2421B) Yes (RIB2421SB) Contact Ratings (RIB2421B): 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 83 mA @ 24 Vac 47 mA @ 120 Vac 69 mA @ 208-277 Vac 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 208-277 Vac ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Contact Ratings (RIB2421SB): 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Notes: · Order Normally Closed by adding "-NC" to end of model number (RIB2421SB) (800) 888-5538 | www.functionaldevices.com 25 RELAYS 20 AMP POWER CONTROL RELAYS RIB2401SBC Enclosed Relay 20 Amp SPDT + Override with 24 Vac/dc/120 Vac Coil RIB2402SBC Enclosed Relay 20 Amp SPDT + Override with 24 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIB2401SBC) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIB2402SBC) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 20 AMP POWER CONTROL RELAY RIB01P Enclosed Relay 20 Amp DPDT with 120 Vac Coil Wht/Blk 120 Vac Wht/Blk 120 Vac Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 105 mA @ 120 Vac 26 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac RELAYS 20 AMP POWER CONTROL RELAY RIB02P Enclosed Relay 20 Amp DPDT with 208-277 Vac Coil Wht/Brn 208-277 Vac Wht/Brn 208-277 Vac Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 105 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac 20 AMP POWER CONTROL RELAY RIB347P Enclosed Relay 20 Amp DPDT with 347 Vac Coil Wht/Org 347 Vac Wht/Org 347 Vac Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O LIGHTING RETROFITS 347 VAC FOR OUR FRIENDS IN CANADA SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 105 mA @ 347 Vac Coil Voltage Input: 347 Vac ; 50-60 Hz Drop Out = 70 Vac Pull In = 295 Vac 27 RELAYS 20 AMP POWER CONTROL RELAY RIB04P Enclosed Relay 20 Amp DPDT with 480 Vac Coil Wht/Grn 480 Vac Wht/Grn 480 Vac Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 105 mA @ 480 Vac Made in USA Meets "Buy American" of ARRA 2009 Coil Voltage Input: 480 Vac ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac 20 AMP POWER CONTROL RELAY RIB243P Enclosed Relay 20 Amp 3PST-N/O with 24 Vac/dc Coil Wht/Yel 24 Vac/dc Blu - N/O Blu - N/O Wht/Yel 24 Vac/dc Yel - N/O Yel - N/O Org - N/O Org - N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Contact Ratings: Coil Current: Expected Relay Life: 10 million cycles minimum mechanical 20 Amp Resistive @ 300 Vac, 28 Vdc 210 mA @ 24 Vac Operating Temperature: -30 to 140° F 20 Amp Ballast @ 277-480 Vac 154 mA @ 30 Vdc Humidity Range: 5 to 95% (noncondensing) Not rated for Electronic Ballast Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc California State Fire Marshal, CE, RoHS 1466 VA Pilot Duty @ 240 Vac, 3 Phase Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase Notes: · Order Normally Closed by adding "-NC" to end of model number 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase 28 Functional Devices, Inc. | American Made. American Owned. 20 AMP POWER CONTROL RELAY RIB013P Enclosed Relay 20 Amp 3PST-N/O with 120 Vac Coil RELAYS Wht/Blk 120 Vac Wht/Blk 120 Vac Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No 20 AMP POWER CONTROL RELAY RIB023P Enclosed Relay 20 Amp 3PST-N/O with 208-277 Vac Coil Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Wht/Brn 208-277 Vac Wht/Brn 208-277 Vac Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 154 mA @ 120 Vac Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac Notes: · Order Normally Closed by adding "-NC" to end of model number Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 187 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac Notes: · Order Normally Closed by adding "-NC" to end of model number 29 RELAYS 20 AMP POWER CONTROL RELAY RIB043P Enclosed Relay 20 Amp 3PST-N/O with 480 Vac Coil Wht/Grn 480 Vac Wht/Grn 480 Vac Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 132 mA @ 480 Vac Coil Voltage Input: 480 Vac ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac Notes: · Order Normally Closed by adding "-NC" to end of model number 30 AMP POWER CONTROL RELAY RIB24Z Enclosed Relay 30 Amp SPST-N/O + SPST-N/C with 24 Vac/dc Coil Wht/Yel Blu 24 Vac/dc N/C Blu N/C Org N/O Wht/Yel 24 Vac/dc Org N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPST-N/O + SPST-N/C Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc 30 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 20 / 30 AMP POWER CONTROL RELAYS RIB12P Enclosed Relay 20 Amp DPDT with 12 Vac/dc Coil RIB12P30 Enclosed Relay 30 Amp DPDT with 12 Vac/dc Coil Wht/Yel 12 Vac/dc Wht/Yel 12 Vac/dc Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Wht/Yel 12 Vac/dc Wht/Yel 12 Vac/dc Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIB12P) 2.30 x 3.20 x 1.80 with .75 NPT Nipple (RIB12P30) Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: (RIB12P) 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Contact Ratings: (RIB12P30) 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 115 mA @ 10 Vac 180 mA @ 12 Vac 79 mA @ 11 Vdc 90 mA @ 12 Vdc 115 mA @ 15 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 4.5 Vac / 4.8 Vdc Pull In = 9.7 Vac / 11 Vdc 20 / 30 AMP POWER CONTROL RELAYS RIB24P Enclosed Relay 20 Amp DPDT with 24 Vac/dc Coil RIB24P30 Enclosed Relay 30 Amp DPDT with 24 Vac/dc Coil Wht/Yel 24 Vac/dc Wht/Yel 24 Vac/dc Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Wht/Yel 24 Vac/dc Wht/Yel 24 Vac/dc Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIB24P) 2.30 x 3.20 x 1.80 with .75 NPT Nipple (RIB24P30) Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, UL60947, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: (RIB24P) 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Contact Ratings: (RIB24P30) 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 31 RELAYS 30 AMP POWER CONTROL RELAYS RIB01P30 Enclosed Relay 30 Amp DPST-N/O with 120 Vac Coil RIB01P30-S Enclosed Relay 30 Amp DPST-N/O + Coil Side Override with 120 Vac Coil Org Org N/O N/O Wht/Blk 120 Vac Wht/Blk 120 Vac Continuous HAND Org N/O Wht/Red OFF Org N/O 120 Vac Control AUTO Brn Brn N/O N/O Wht/Blk 120 Vac Wht/Yel Brn Neutral Brn N/O N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No (RIB01P30) Coil Side (RIB01P30-S) Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 105 mA @ 120 Vac Control Input: (RIB01P30-S) Wht/Blk = 120 Vac Continuous Wht/Red = 120 Vac Control Wht/Yel = Neutral Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac Notes: · Order Both Poles Normally Closed by adding "-NC" to end of model number · Order Pole 1 Normally Open and Pole 2 Normally Closed by adding "-NONC" to end of model number 30 AMP POWER CONTROL RELAY RIB02P30 Enclosed Relay 30 Amp DPST-N/O with 208-277 Vac Coil Wht/Brn 208-277 Vac Wht/Brn 208-277 Vac Org N/O Pole 1 Org N/O Brn N/O Pole 2 Brn N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 105 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac Notes: · Order Both Poles Normally Closed by adding "-NC" to end of model number · Order Pole 1 Normally Open and Pole 2 Normally Closed by adding "-NONC" to end of model number 32 Functional Devices, Inc. | American Made. American Owned. RELAYS 20 AMP POWER CONTROL RELAYS RIBT24B Enclosed Relay Hi/Low Separation 20 Amp SPDT with 24 Vac/dc Coil RIBT24SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override with 24 Vac/dc Coil 24 Vac/dc Comm Blu N/C Yel Comm Org N/O 24 Vac/dc Comm Selectable Jumper Wire Org CLOSED Org OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBT24B) One (1) SPST Continuous Duty Coil (RIBT24SB) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIBT24B) Yes (RIBT24SB) Contact Ratings (RIBT24B): 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 45 mA @ 18 Vac 75 mA @ 24 Vac 30 mA @ 22 Vdc 32 mA @ 24 Vdc 42 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Contact Ratings (RIBT24SB): 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Notes: · Normally Open or Normally Closed selected by yellow jumper wire (RIBT24SB) 20 AMP POWER CONTROL RELAYS RIBT2401B Enclosed Relay Hi/Low Separation 20 Amp SPDT with 24 Vac/dc/120 Vac Coil RIBT2402B Enclosed Relay Hi/Low Separation 20 Amp SPDT with 24 Vac/dc/208-277 Vac Coil 120 Vac 24 Vac/dc Comm Blu N/C Yel Comm Org N/O 208-277 Vac 24 Vac/dc Comm Blu N/C Yel Comm Org N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBT2401B) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBT2402B) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 33 RELAYS 20 AMP POWER CONTROL RELAYS RIBT2401SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override with 24 Vac/dc/120 Vac Coil RIBT2402SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override with 24 Vac/dc/208-277 Vac Coil Selectable Jumper Wire Selectable Jumper Wire 120 Vac Org 208-277 Vac Org Made in USA Meets "Buy American" of ARRA 2009 24 Vac/dc Comm CLOSED Org OPEN AUTO 24 Vac/dc Comm CLOSED Org OPEN AUTO SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401SB) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402SB) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBT2401SB) 69 mA @ 208-277 Vac (RIBT2402SB) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Notes: · Normally Open or Normally Closed selected by yellow jumper wire 20 AMP POWER CONTROL RELAYS RIBT2401SBC Enclosed Relay Hi/Low Separation 20 Amp SPDT + Override with 24 Vac/dc/120 Vac Coil RIBT2402SBC Enclosed Relay Hi/Low Separation 20 Amp SPDT + Override with 24 Vac/dc/208-277 Vac Coil 120 Vac 24 Vac/dc Comm 208-277 Vac 24 Vac/dc Comm Made in USA Meets "Buy American" of ARRA 2009 Yel MANUAL Comm AUTO Blu N/C - CLOSED N/C OPEN Org N/O - CLOSED N/O Yel MANUAL Comm AUTO Blu N/C - CLOSED N/C OPEN Org N/O - CLOSED N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBT2401SBC) 69 mA @ 208-277 Vac (RIBT2402SBC) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc 34 Functional Devices, Inc. | American Made. American Owned. 20 AMP TIME DELAY RELAY RIBTD2401B Enclosed Time Delay Relay 20 Amp SPDT with 24 Vac/dc/120 Vac Coil RELAYS 120 Vac 24 Vac/dc Comm Blu N/C Yel Comm Org N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms after time delay Relay Status: RED LED On = Activated Time Delay Status: PINK LED FLASHING = Timing Timing Mode: Delay On Make (N/O) Timing Range: 6 seconds - 20 minutes Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5% Timing Repeatability: +1% Temperature Timing Variance: +1% Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: Input Current: 20 Amp Resistive @ 277 Vac 133 mA @ 24 Vac 20 Amp Ballast @ 277 Vac 45 mA @ 24 Vdc 16 Amp Electronic Ballast @ 277 Vac (N/O) 51 mA @ 120 Vac 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Timing Adjustment Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc C BD AE Range Selection 1234 Only Close 1 Switch Depressed for closed Depressed for open Switch Ranges 6s-20s 22s-1min15s 1min30s-5min 6min-20min TIMING TABLE Close Dip Switch A Potentiometer Setting B C D 1 6s 9s 13s 16s 2 22s 36s 50s 1min4s 3 1min30s 2min10s 3min20s 4min16s 4 6min 9min 13min20s 17min20s E 20s 1min15s 5min 20min Time Delay Application Example #1 Load 2 stays ON selected amount of time after Load 1 turns ON (N/C) Load 2 stays OFF selected amount of time after Load 1 turns ON (N/O) Load 1 (Thermostat Controlled Heater, for example) 120 Vac Blu Time Delay Application Example #2 (Requires an Inverting Relay) Load 2 stays ON selected amount of time after Load 1 turns OFF (N/C) Load 2 stays OFF selected amount of time after Load 1 turns OFF (N/O) 120 Vac Hot Load 1 (Thermostat Blu Controlled Heater, for example) Blu Load 2 (Circulating Fan, for example) Load 1 Voltage Load 2 on N/O Contact Load 2 on N/C Contact Yel RIBTD2401B Time Delay Time Delay Load 2 (Circulating Fan, for example) Yel RIB® Select RIB® with coil input appropriate to sense Load 1. Present Absent ON OFF ON OFF Load 1 Voltage Load 2 on N/O Contact Load 2 on N/C Contact (800) 888-5538 | www.functionaldevices.com Yel RIBTD2401B Neutral Time Delay Time Delay Present Absent ON OFF ON OFF 35 RELAYS 20 AMP POWER CONTROL RELAYS RIBT242B Enclosed Relays Hi/Low Separation 20 Amp 2 SPDT with 24 Vac/dc Coil RELAY 2 24 Vac/dc Gry - N/C Prp - Comm RELAY 1 24 Vac/dc Brn - N/O Blu - N/C Comm Yel - Comm Org - N/O All relay coils use the same common RIBT243B Enclosed Relays Hi/Low Separation 20 Amp 2 SPST + 1 SPDT with 24 Vac/dc Coil RELAY 3 24 Vac/dc Gry - N/C Prp - Comm RELAY 2 24 Vac/dc Brn - N/O Yel - N/O RELAY 1 24 Vac/dc Yel - N/O Blu - N/O Comm Blu - N/O All relay coils use the same common Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil (RIBT242B) Two (2) SPST + One (1) SPDT Continuous Duty Coil (RIBT243B) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Notes: · RIBT243B not rated for UL864. 20 AMP POWER CONTROL RELAY RIBT24P Enclosed Relay Hi/Low Separation 20 Amp DPDT with 24 Vac/dc Coil 24 Vac/dc Comm Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 36 Functional Devices, Inc. | American Made. American Owned. RELAYS 30 AMP POWER CONTROL RELAY RIBT24Z Enclosed Relay Hi/Low Separation 30 Amp SPST-N/O + SPST-N/C with 24 Vac/dc Coil 24 Vac/dc Comm Blu - N/C Blu - N/C Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPST-N/O + One (1) SPST-N/C Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Made in USA Meets "Buy American" of ARRA 2009 Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 20 AMP POWER CONTROL RELAY RIBT243P Enclosed Relay Hi/Low Separation 20 Amp 3PST-N/O with 24 Vac/dc Coil 24 Vac/dc Comm Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number 37 RELAYS 20 AMP TRACK MOUNT CONTROL RELAYS RIBM2401B 4.00 Track Mount Relay 20 Amp SPDT with 24 Vac/dc/120 Vac Coil RIBM2402B 4.00 Track Mount Relay 20 Amp SPDT with 24 Vac/dc/208-277 Vac Coil Comm 24 Vac/dc Comm N/O Comm 24 Vac/dc Comm N/O Made in USA Meets "Buy American" of ARRA 2009 120 Vac N/C 208-277 Vac N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.250 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBM2401B) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBM2402B) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 20 AMP TRACK MOUNT CONTROL RELAYS RIBM2401SB 4.00 Track Mount Relay 20 Amp SPST + Override with 24 Vac/dc/120 Vac Coil RIBM2402SB 4.00 Track Mount Relay 20 Amp SPST + Override with 24 Vac/dc/208-277 Vac Coil Comm Selectable Jumper Wire Comm Selectable Jumper Wire 24 Vac/dc 24 Vac/dc 120 Vac CLOSED OPEN AUTO Not Used 208-277 Vac CLOSED OPEN AUTO Not Used Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.600 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBM2401SB) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBM2402SB) Notes: · Normally Open or Normally Closed selected by yellow jumper wire Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401SB) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402SB) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 38 Functional Devices, Inc. | American Made. American Owned. 20 AMP TRACK MOUNT CONTROL RELAYS RIBM2401SBC 4.00 Track Mount Relay 20 Amp SPDT + Override with 24 Vac/dc/120 Vac Coil RIBM2402SBC 4.00 Track Mount Relay 20 Amp SPDT + Override with 24 Vac/dc/208-277 Vac Coil Comm 24 Vac/dc 120 Vac AUTO MANUAL N/C N/O CLOSED CLOSED OPEN Comm N/O N/C Comm 24 Vac/dc 208-277 Vac AUTO MANUAL N/C N/O CLOSED CLOSED OPEN Comm N/O N/C Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.350 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes (2) 30 AMP TRACK MOUNT CONTROL RELAY RIBM24ZN 4.00 Track Mount Relay 30 Amp DPDT with 24 Vac/dc Coil 24 Vac/dc Comm N/C N/O Comm N/C N/O Comm Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBM2401SBC) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBM2402SBC) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.600 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac NEMA B600 Pilot Duty Coil Current: 110 mA @ 20 Vac 125 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 70 mA @ 30 Vdc (800) 888-5538 | www.functionaldevices.com Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 39 RELAYS 30 AMP TRACK MOUNT CONTROL RELAY RIBM24ZL 4.00 Track Mount Relay 30 Amp DPST-N/O with 24 Vac/dc Coil Comm 24 Vac/dc Comm N/O Comm N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.350 x 4.000 x 2.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number 30 AMP TRACK MOUNT CONTROL RELAY RIBMN24ZL 2.75 Track Mount Relay 30 Amp DPST-N/O with 24 Vac/dc Coil Comm 24 Vac/dc Comm N/O Comm N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.350 x 2.750 x 2.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number 40 Functional Devices, Inc. | American Made. American Owned. RELAYS 30 AMP TRACK MOUNT CONTROL RELAY RIBM243PN 4.00 Track Mount Relay 30 Amp 3PDT with 24 Vac/dc Coil N/C N/O Comm N/C 24 Vac/dc Comm N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.450 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1110 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 190 mA @ 24 Vac 140 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc 30 AMP TRACK MOUNT CONTROL RELAY RIBM013PN 4.00 Track Mount Relay 30 Amp 3PDT with 120 Vac Coil N/C N/O Comm N/C Comm Not Used 120 Vac N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.450 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1110 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 140 mA @ 120 Vac Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac 41 RELAYS 30 AMP TRACK MOUNT CONTROL RELAY RIBM023PN 4.00 Track Mount Relay 30 Amp 3PDT with 208-277 Vac Coil N/C N/O Comm N/C Comm Not Used 208-277 Vac N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.450 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1110 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase Coil Current: 170 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac 30 AMP TRACK MOUNT CONTROL RELAY RIBM043PN 4.00 Track Mount Relay 30 Amp 3PDT with 480 Vac Coil N/C Made in USA Meets "Buy American" of ARRA 2009 N/O Comm N/C Comm Not Used 480 Vac N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.450 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1110 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase 42 Functional Devices, Inc. | American Made. American Owned. Coil Current: 140 mA @ 480 Vac Coil Voltage Input: 480 Vac/dc ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac Notes: · See model RIBM043PN-HD for use in more transient prone environments RELAYS 30 AMP TRACK MOUNT CONTROL RELAY RIBM043PN-HD 4.00 Track Mount Relay 30 Amp 3PDT with 480 Vac Coil (-HD for More Transient Prone Environments) N/C N/O Comm N/C Comm Not Used 480 Vac N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 3.250 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1110 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase Coil Current: 140 mA @ 480 Vac Coil Voltage Input: 480 Vac/dc ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac (800) 888-5538 | www.functionaldevices.com 43 RELAYS LATCHING RELAYS Enclosed Features · Prepackaged for convenience · Electromechanical relay · Mechanically latching · Status output contact · Electronic ballast rating · 20 Amp rating 24 Vac Supply Controller On Common O Latch Unlatch N/O Momentary Wall Switch Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Local Power 120-277 Vac Lighting Status to Controller N/O Momentary Wall Switch ENCLOSED LATCHING RELAYS COIL VOLTAGE MODEL # RIBL12B · RIBL12BM · RIBL12SB · RIBL12SBM · RIBL24B · RIBL24BM · RIBL24SB · RIBL24SBM · AC/DC 12 12 12 12 24 24 24 24 RELAYS 1 1 1 1 1 1 1 1 CONTACTS SPST SPST SPST SPST SPST SPST SPST SPST OVERRIDE SWITCH · · AUXILIARY OUTPUT · · · · · · NOTES = UL Listed : UL60947 Low-Voltage Switchgear and Controlgear SPEC PAGE 45 45 45 45 46 46 46 46 44 Functional Devices, Inc. | American Made. American Owned. RELAYS LATCHING RELAYS RIBL12B Enclosed Mechanically Latching Relay 20 Amp SPST with 12 Vac/dc Coil RIBL12BM Enclosed Mechanically Latching Relay 20 Amp SPST with 12 Vac/dc Coil, Status LED and Auxiliary Output Made in USA Meets "Buy American" of ARRA 2009 Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Wht/Red 12 Vac/dc () UNLATCH Org Line Org Load Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Wht/Red 12 Vac/dc () UNLATCH SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary Contact Closed: LED On = Voltage Detected on Load Wire (RIBL12BM) Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT Nipple (RIBL12B) 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIBL12BM) Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Yel Line Org Load Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry RIBL12B-RD · Red housing RIBL12B-N4 · NEMA 4X housing (Not available on switched models) Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 182 mA @ 10 Vac 20 Amp Ballast @ 120-277 Vac 250 mA @ 12 Vac 16 Amp Electronic Ballast @ 120-277 Vac 165 mA @ 10 Vdc 5540 Watt Tungsten @ 277 Vac 198 mA @ 12 Vdc 720 VA Pilot Duty @ 120-277 Vac 250 mA @ 15 Vdc 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Latch / Unlatch: Min. 10 Vdc / 11 Vac Auxiliary Contact: Notes: 3 Amp @ 30 Vac/dc max. · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL12BM) LATCHING RELAYS RIBL12SB Enclosed Mechanically Latching Relay 20 Amp SPST + Override with 12 Vac/dc Coil Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Org Line * Wht/Red 12 Vac/dc () UNLATCH Org Load * Mechanically latches and unlatches with a coil input or by manual override RIBL12SBM Enclosed Mechanically Latching Relay 20 Amp SPST + Override with 12 Vac/dc Coil, Status LED and Auxiliary Output Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Wht/Red 12 Vac/dc () UNLATCH * Mechanically latches and unlatches with a coil input or by manual override Yel Line * Org Load Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary Contact Closed: LED On = Voltage Detected on Load Wire (RIBL12SBM) Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT Nipple (RIBL12SB) 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIBL12SBM) Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 182 mA @ 10 Vac 20 Amp Ballast @ 120-277 Vac 250 mA @ 12 Vac 16 Amp Electronic Ballast @ 120-277 Vac 165 mA @ 10 Vdc 5540 Watt Tungsten @ 277 Vac 198 mA @ 12 Vdc 720 VA Pilot Duty @ 120-277 Vac 250 mA @ 15 Vdc 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Latch / Unlatch: Min. 10 Vdc / 11 Vac Auxiliary Contact: Notes: 3 Amp @ 30 Vac/dc max. · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL12SBM) (800) 888-5538 | www.functionaldevices.com 45 RELAYS LATCHING RELAYS RIBL24B Enclosed Mechanically Latching Relay 20 Amp SPST with 24 Vac/dc Coil RIBL24BM Enclosed Mechanically Latching Relay 20 Amp SPST with 24 Vac/dc Coil, Status LED and Auxiliary Output Made in USA Meets "Buy American" of ARRA 2009 Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Wht/Red 24 Vac/dc () UNLATCH Org Line Org Load Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Wht/Red 24 Vac/dc () UNLATCH SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary Contact Closed: LED On = Voltage Detected on Load Wire (RIBL24BM) Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT Nipple (RIBL24B) 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIBL24BM) Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Yel Line Org Load Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry RIBL24B-RD · Red housing RIBL24B-N4 · NEMA 4X housing (Not available on switched models) Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 175 mA @ 20 Vac 20 Amp Ballast @ 120-277 Vac 210 mA @ 24 Vac 16 Amp Electronic Ballast @ 120-277 Vac 92 mA @ 20 Vdc 5540 Watt Tungsten @ 277 Vac 110 mA @ 24 Vdc 720 VA Pilot Duty @ 120-277 Vac 138 mA @ 30 Vdc 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Latch / Unlatch: Min. 20 Vdc / 22 Vac Auxiliary Contact: Notes: 3 Amp @ 30 Vac/dc max. · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL24BM) LATCHING RELAYS RIBL24SB Enclosed Mechanically Latching Relay 20 Amp SPST + Override with 24 Vac/dc Coil Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Org Line * Wht/Red 24 Vac/dc () UNLATCH Org Load * Mechanically latches and unlatches with a coil input or by manual override RIBL24SBM Enclosed Mechanically Latching Relay 20 Amp SPST + Override with 24 Vac/dc Coil, Status LED and Auxiliary Output Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Wht/Red 24 Vac/dc () UNLATCH * Mechanically latches and unlatches with a coil input or by manual override Yel Line * Org Load Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary Contact Closed: LED On = Voltage Detected on Load Wire (RIBL24SBM) Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT Nipple (RIBL24SB) 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIBL24SBM) Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes 46 Functional Devices, Inc. | Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 175 mA @ 20 Vac 20 Amp Ballast @ 120-277 Vac 210 mA @ 24 Vac 16 Amp Electronic Ballast @ 120-277 Vac 92 mA @ 20 Vdc 5540 Watt Tungsten @ 277 Vac 110 mA @ 24 Vdc 720 VA Pilot Duty @ 120-277 Vac 138 mA @ 30 Vdc 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Latch / Unlatch: Min. 20 Vdc / 22 Vac Auxiliary Contact: Notes: 3 Amp @ 30 Vac/dc max. · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL24SBM) American Made. American Owned. RELAYS LOW-INPUT / OPTOISOLATED RELAYS Enclosed | Track Mount Prepackaged Like the Original RIB® with Special Features · Extremely low current draw on the input · Control input can connect to AO for relay control · Protect controller from feedback or voltage transients Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Controller High Voltage 60 Hz ac Controller Low Voltage 60 Hz ac Digital Out (or Analog Out) Power Supply Relay Opto Input Opto RIB® Load 24 Vac/dc Analog or Digital Out Power Supply Relay Opto Input Opto RIB® Load · Optoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from analog outputs. ENCLOSED LOW-INPUT / OPTOISOLATED RELAYS MODEL # RIBTELC CONTROL INPUT · 5-25 Vac/dc RIBTELS · 5-25 Vac/dc RIBTE24B · 5-25 Vac/dc RIBTE01B · 5-25 Vac/dc RIBTE02B · 5-25 Vac/dc RIBTE24SB · 5-25 Vac/dc RIBTE01SB · 5-25 Vac/dc RIBTE02SB · 5-25 Vac/dc RIBTE24P · 5-25 Vac/dc RIBTE01P · 5-25 Vac/dc RIBTE02P · 5-25 Vac/dc RIBTE01P-S · 5-25 Vac/dc RIBTE02P-S · 5-25 Vac/dc POWER INPUT 10-30 Vac/dc 10-30 Vac/dc 24 Vac/dc 120 Vac 208-277 Vac 24 Vac/dc 120 Vac 208-277 Vac 24 Vac/dc 120 Vac 208-277 Vac 120 Vac 208-277 Vac RELAYS 1 1 1 1 1 1 1 1 1 1 1 1 1 CONTACTS SPDT SPST SPDT SPDT SPDT SPST SPST SPST DPDT DPDT DPDT DPDT DPDT OVERRIDE SWITCH 1 1 1 1 1 1 NOTES SPEC PAGE 48 48 48 49 49 50 50 51 51 52 52 53 53 TRACK MOUNT LOW-INPUT / OPTOISOLATED RELAYS MODEL # RIBME2401B CONTROL INPUT · 5-25 Vac/dc RIBME2402B · 5-25 Vac/dc RIBME2401SB · 5-25 Vac/dc RIBME2402SB · 5-25 Vac/dc RIBME2401P · 5-25 Vac/dc RIBME2402P · 5-25 Vac/dc POWER INPUT 24 Vac/dc/120 Vac 24 Vac/dc/208-277 Vac 24 Vac/dc/120 Vac 24 Vac/dc/208-277 Vac 24 Vac/dc/120 Vac 24 Vac/dc/208-277 Vac RELAYS 1 1 1 1 1 1 CONTACTS SPDT SPDT SPST SPST DPST DPST = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada OVERRIDE SWITCH 1 1 NOTES SPEC PAGE 53 53 54 54 54 54 (800) 888-5538 | www.functionaldevices.com 47 RELAYS LOW COIL INPUT RELAYS RIBTELC Enclosed Relay Hi/Low Separation 10 Amp SPDT, 10-30 Vac/dc Power Input + 5-25 Vac/dc Control Input RIBTELS Enclosed Relay Hi/Low Separation 10 Amp SPST + Override, 10-30 Vac/dc Power Input + 5-25 Vac/dc Control Input Made in USA Meets "Buy American" of ARRA 2009 5-25 Vac/dc CONTROL INPUT 10-30 Vac/dc POWER INPUT Blu - N/C Yel - Comm Org - N/O 5-25 Vac/dc CONTROL INPUT 10-30 Vac/dc POWER INPUT Selectable Jumper Wire Org CLOSED Org OPEN AUTO SPECIFICATIONS Power Input: 10-30 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes (RIBTELC), No (RIBTELS) Override Switch: No (RIBTELC), Yes (RIBTELS) Contact Ratings: 10 Amp Resistive @ 120-277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Power Input Ratings: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Normally Open or Normally Closed selected by yellow jumper wire (RIBTELS) LOW COIL INPUT RELAY RIBTE24B Enclosed Relay Hi/Low Separation 20 Amp SPDT, 24 Vac/dc Power Input + 5-25 Vac/dc Control Input 24 Vac/dc POWER INPUT Blu - N/C Yel - Comm 5-25 Vac/dc CONTROL INPUT Org - N/O SPECIFICATIONS Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) 48 Functional Devices, Inc. | American Made. American Owned. LOW COIL INPUT RELAY RIBTE01B Enclosed Relay Hi/Low Separation 20 Amp SPDT, 120 Vac Power Input + 5-25 Vac/dc Control Input RELAYS 5-25 Vac/dc CONTROL INPUT Wht/Blk 120 Vac POWER INPUT Wht/Blk Blu - N/C Yel - Comm Org - N/O SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: Power Input Ratings: 20 Amp Resistive @ 277 Vac 47 mA @ 120 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) LOW COIL INPUT RELAY RIBTE02B Enclosed Relay Hi/Low Separation 20 Amp SPDT, 208-277 Vac Power Input + 5-25 Vac/dc Control Input 5-25 Vac/dc CONTROL INPUT Wht/Brn 208-277 Vac POWER INPUT Wht/Brn Blu - N/C Yel - Comm Org - N/O SPECIFICATIONS Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: Power Input Ratings: 20 Amp Resistive @ 277 Vac 69 mA @ 208-277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) 49 LOW COIL INPUT RELAY RIBTE24SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override, 24 Vac/dc Power Input + 5-25 Vac/dc Control Input 24 Vac/dc POWER INPUT Selectable Jumper Wire Org RELAYS 5-25 Vac/dc CONTROL INPUT CLOSED Org OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Normally Open or Normally Closed selected by yellow jumper wire LOW COIL INPUT RELAY RIBTE01SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override, 120 Vac Power Input + 5-25 Vac/dc Control Input Wht/Blk 120 Vac POWER INPUT Wht/Blk 5-25 Vac/dc CONTROL INPUT Selectable Jumper Wire Org CLOSED Org OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Power Input Ratings: 47 mA @ 120 Vac Notes: · Normally Open or Normally Closed selected by yellow jumper wire 50 Functional Devices, Inc. | American Made. American Owned. RELAYS LOW COIL INPUT RELAY RIBTE02SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override, 208-277 Vac Power Input + 5-25 Vac/dc Control Input Wht/Brn 208-277 Vac POWER INPUT Wht/Brn 5-25 Vac/dc CONTROL INPUT Selectable Jumper Wire Org CLOSED Org OPEN AUTO SPECIFICATIONS Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes LOW COIL INPUT RELAY RIBTE24P Enclosed Relay Hi/Low Separation 20 Amp DPDT, 24 Vac/dc Power Input + 5-25 Vac/dc Control Input Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 69 mA @ 208-277 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Normally Open or Normally Closed selected by yellow jumper wire 24 Vac/dc POWER INPUT 5-25 Vac/dc CONTROL INPUT Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O SPECIFICATIONS Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Power Input Ratings: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Made in USA Meets "Buy American" of ARRA 2009 Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) (800) 888-5538 | www.functionaldevices.com 51 RELAYS LOW COIL INPUT RELAY RIBTE01P Enclosed Relay Hi/Low Separation 20 Amp DPDT, 120 Vac Power Input + 5-25 Vac/dc Control Input Wht/Blk 120 Vac POWER INPUT Wht/Blk 5-25 Vac/dc CONTROL INPUT Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Power Input Ratings: 105 mA @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) LOW COIL INPUT RELAY RIBTE02P Enclosed Relay Hi/Low Separation 20 Amp DPDT, 208-277 Vac Power Input + 5-25 Vac/dc Control Input Wht/Brn 208-277 Vac POWER INPUT Wht/Brn 5-25 Vac/dc CONTROL INPUT Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O SPECIFICATIONS Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Power Input Ratings: 105 mA @ 208-277 Vac 52 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) RELAYS LOW COIL INPUT RELAYS RIBTE01P-S Enclosed Relay Hi/Low Separation 20 Amp DPDT +Override, 120 Vac Power Input + 5-25 Vac/dc Control Input Wht/Blk 120 Vac POWER INPUT COIL ON COIL OFF AUTO Wht/Blk Blu - N/C Yel - Comm Org - N/O Gry - N/C 5-25 Vac/dc CONTROL INPUT Prp - Comm Brn - N/O RIBTE02P-S Enclosed Relay Hi/Low Separation 20 Amp DPDT +Override, 208-277 Vac Power Input + 5-25 Vac/dc Control Input Wht/Brn 208-277 Vac POWER INPUT COIL ON COIL OFF AUTO Wht/Brn Blu - N/C Yel - Comm Org - N/O Gry - N/C 5-25 Vac/dc CONTROL INPUT Prp - Comm Brn - N/O SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz (RIBTE01P-S) 208-277 Vac, 50-60 Hz (RIBTE02P-S) Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes* Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Made in USA Meets "Buy American" of ARRA 2009 Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Override capability is made possible by supplying constant voltage on the Power Input. No Control Input Voltage is necessary to override the relay. * Power Input Ratings: 105 mA @ 120 Vac (RIBTE01P-S) 105 mA @ 208-277 Vac (RIBTE02P-S) LOW COIL INPUT TRACK MOUNT RELAYS RIBME2401B 4.00 Track Mount Relay 20 Amp SPDT, 24 Vac/dc/120 Vac Power Input + 5-25 Vac/dc Control Input RIBME2402B 4.00 Track Mount Relay 20 Amp SPDT, 24 Vac/dc/208-277 Vac Power Input + 5-25 Vac/dc Control Input 5-25 Vac/dc CONTROL INPUT Comm Comm N/O 5-25 Vac/dc CONTROL INPUT Comm Comm N/O 24 Vac/dc N/C POWER INPUTS 120 Vac 24 Vac/dc N/C POWER INPUTS 208-277 Vac Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Power Input: 24 Vac/dc/120 Vac, 50-60 Hz (RIBME2401B) 24 Vac/dc/208-277 Vac, 50-60 Hz (RIBME2402B) Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.050 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Power Input Ratings: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBME2401B) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBME2402B) Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) 53 RELAYS LOW COIL INPUT TRACK MOUNT RELAYS RIBME2401SB 4.00 Track Mount Relay 20 Amp SPST + Override, 24 Vac/dc/120 Vac Power Input + 5-25 Vac/dc Control Input RIBME2402SB 4.00 Track Mount Relay 20 Amp SPST + Override, 24 Vac/dc/208-277 Vac Power Input + 5-25 Vac/dc Control Input 5-25 Vac/dc CONTROL INPUT 5-25 Vac/dc CONTROL INPUT Comm Selectable Jumper Wire Comm Selectable Jumper Wire 24 Vac/dc POWER INPUTS 120 Vac CLOSED OPEN AUTO Not Used 24 Vac/dc POWER INPUTS 208-277 Vac CLOSED OPEN AUTO Not Used Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Power Input: 24 Vac/dc/120 Vac, 50-60 Hz (RIBME2401SB) 24 Vac/dc/208-277 Vac, 50-60 Hz (RIBME2402SB) Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.550 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc 2 mA @ 24 Vdc .9 mA @ 10 Vdc 3 mA @ 24 Vac 1 mA @ 12 Vdc (Non Polarized) Power Input Ratings: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBME2401SB) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBME2402SB) Notes: · Normally Open or Normally Closed selected by yellow jumper wire LOW COIL INPUT TRACK MOUNT RELAYS RIBME2401P 4.00 Track Mount Relay 20 Amp DPST, 24 Vac/dc/120 Vac Power Input + 5-25 Vac/dc Control Input RIBME2402P 4.00 Track Mount Relay 20 Amp DPST, 24 Vac/dc/208-277 Vac Power Input + 5-25 Vac/dc Control Input 5-25 Vac/dc CONTROL INPUT 5-25 Vac/dc CONTROL INPUT Comm 24 Vac/dc POWER INPUTS 120 Vac N/O Comm N/O Comm Comm 24 Vac/dc POWER INPUTS 208-277 Vac N/O Comm N/O Comm Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Power Input: 24 Vac/dc/120 Vac, 50-60 Hz (RIBME2401P) 24 Vac/dc/208-277 Vac, 50-60 Hz (RIBME2402P) Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 3.100 x 4.000 x 2.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No 54 Functional Devices, Inc. Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc, 15 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac | American Made. American Owned. Power Input Ratings: 138 mA @ 24 Vac 105 mA @ 120 Vac (RIBME2401P) 105 mA @ 208-277 Vac (RIBME2402P) 77 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) RELAYS POLARIZED RELAYS Enclosed | Track Mount Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Same Great Prepackaging · Relays are polarized to work in a supervised system and may be turned on and off by reversing polarity. For fire alarm systems, smoke control systems, etc. Fire Alarm Systems Application · Coil input is polarity sensitive · For use with fire alarm systems · System supervision for controllers that utilize end-of-line resistors · Four wire circuit ensures indication of broken wiring connection with RIB® Load Load RIB24C-FA Coil + RIB24C-FA Coil + Controller Signaling Circuit End of Line Resistor ENCLOSED ALARM RELAYS MODEL # RIB12C-FA RIB24C-FA RIB12S-FA RIB24S-FA RIBT24B-FA RIB24P-FA COIL VOLTAGE · 12 Vac/dc · 24 Vac/dc · 12 Vac/dc · 24 Vac/dc · 24 Vac/dc · 24 Vac/dc RELAYS 1 1 1 1 1 1 CONTACTS SPDT SPDT SPST SPST SPDT DPDT OVERRIDE SWITCH 1 1 NOTES SPEC PAGE 56 56 56 56 57 57 TRACK MOUNT ALARM RELAYS MODEL # COIL VOLTAGE RIBMN12C-FA · 12 Vac/dc RIBMN24C-FA · 24 Vac/dc RIBMN12S-FA · 12 Vac/dc RIBMN24S-FA · 24 Vac/dc RELAYS 1 1 1 1 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada CONTACTS SPDT SPDT SPST SPST OVERRIDE SWITCH 1 1 NOTES SPEC PAGE 58 58 58 58 (800) 888-5538 | www.functionaldevices.com 55 RELAYS FIRE ALARM RELAYS RIB12C-FA Enclosed Relay 10 Amp, Polarized with 12 Vac/dc Coil 2nd Wht/Blu 12 Vac/dc Wht/Blu + Blu 12 Vac/dc N/C RIB12S-FA Enclosed Relay 10 Amp + Override, Polarized with 12 Vac/dc Coil 2nd Wht/Blu 12 Vac/dc Wht/Blu + 12 Vac/dc Org Made in USA Meets "Buy American" of ARRA 2009 Wht/Yel Comm 2nd Wht/Yel Comm Yel Comm Org N/O Wht/Yel Comm 2nd Wht/Yel Comm CLOSED Org OPEN AUTO SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIB12C-FA) Yes (RIB12S-FA) Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac RIB12C-FA-RD RIB12S-FA-RD · Red housing RIB12C-FA-N4 · NEMA 4X housing, UL508 only Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 36 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number (RIB12S-FA) FIRE ALARM RELAYS RIB24C-FA Enclosed Relay 10 Amp, Polarized with 24 Vac/dc Coil 2nd Wht/Blu 24 Vac/dc Wht/Blu + Blu 24 Vac/dc N/C RIB24S-FA Enclosed Relay 10 Amp + Override, Polarized with 24 Vac/dc Coil 2nd Wht/Blu 24 Vac/dc Wht/Blu + 24 Vac/dc Org Made in USA Meets "Buy American" of ARRA 2009 Wht/Yel Comm 2nd Wht/Yel Comm Yel Comm Org N/O Wht/Yel Comm 2nd Wht/Yel Comm CLOSED Org OPEN AUTO RIB24C-FA-RD RIB24S-FA-RD · Red housing RIB24C-FA-N4 · NEMA 4X housing, UL508 only SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIB24C-FA) Yes (RIB24S-FA) Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number (RIB24S-FA) 56 Functional Devices, Inc. | American Made. American Owned. RELAYS FIRE ALARM RELAY RIBT24B-FA Enclosed Relay Hi/Low Separation 20 Amp SPDT, Polarized with 24 Vac/dc Coil Comm 24 Vac/dc + Blu N/C Yel Comm Org N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 47 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc FIRE ALARM RELAY RIB24P-FA Enclosed Relay 20 Amp DPDT, Polarized with 24 Vac/dc Coil 2nd Wht/Blu 24 Vac/dc Wht/Blu + 24 Vac/dc Wht/Yel Comm 2nd Wht/Yel Comm Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc, 15 Vdc 15 Amp Resistive @ 600 Vac 1 HP @ 120 Vac 2 HP @ 240-277 Vac 3 HP @ 480 Vac - 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc (800) 888-5538 | www.functionaldevices.com Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 57 RELAYS FIRE ALARM TRACK MOUNT RELAYS RIBMN12C-FA 2.75 Track Mount Relay 15 Amp, Polarized with 12 Vac/dc Coil RIBMN12S-FA 2.75 Track Mount Relay 15 Amp + Override, Polarized with 12 Vac/dc Coil 12 Vac/dc + Comm N/C Comm N/O 12 Vac/dc + Comm AUTO OPEN CLOSED Comm N/O or N/C Selectable Jumpers (must cut one only) SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.100 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN12C-FA) Yes (RIBMN12S-FA) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Made in USA Meets "Buy American" of ARRA 2009 Cut for N/O Cut for N/C Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN12S-FA) FIRE ALARM TRACK MOUNT RELAYS RIBMN24C-FA 2.75 Track Mount Relay 15 Amp, Polarized with 24 Vac/dc Coil RIBMN24S-FA 2.75 Track Mount Relay 15 Amp + Override, Polarized with 24 Vac/dc Coil Comm 24 Vac/dc N/C Comm N/O 24 Vac/dc + Comm AUTO OPEN CLOSED Comm N/O or N/C Selectable Jumpers (must cut one only) SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.100 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN24C-FA) Yes (RIBMN24S-FA) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Made in USA Meets "Buy American" of ARRA 2009 Cut for N/O Cut for N/C Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN24S-FA) 58 Functional Devices, Inc. | American Made. American Owned. DRY CONTACT INPUT RELAYS Enclosed | Track Mount Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). The Dry Contact Input RIB® Series offers all the advantages of the standard RIB® line plus it can be activated by a wide range of dry contacts such as thermostats, current switches, other relays, solid-state switches, etc. The Dry Contact Input RIB® accepts local power to provide the low-voltage (Class 2) power needed to activate the relay; just close the dry contact input. The power to energize the relay can be brought to the relay on a separate pair of wires along with the control output of a controller, or can be a local power source near the relay. The relay contacts are isolated from the input power and the dry contact input; thus, the relay contacts can be wired to switch any other power-load or low-voltage load (see specifications for contact ratings.) One model can be used for many installations (model RIB21CDC can be powered from any voltage from 120 Vac to 277 Vac; see specifications for the input power of other models.) RELAYS Can be activated by dry contacts such as thermostats, current switches, etc. · Self-powered current switches of the RIBX Series and relays of the Dry Contact Input RIB® Series may be applied to interlock Load 2 to Load 1. Current sensing may be internal or external Wire Being Monitored Load 1 RIBX Series Current Sensor Only (Class 2) Current Sensor Status Local Power 120, 208, 240, 277 Vac Dry Contact Input RIB® Series Load 2 ENCLOSED DRY CONTACT INPUT RELAYS MODEL # RIB21CDC · RIB01BDC · RIB02BDC · RIB01SBDC · RIB02SBDC · RIB01SBCDC · RIB02SBCDC · RIBD01BDC · RIBD02BDC · RIBD01BDC-DOB · RIBD02BDC-DOB · POWER INPUT 120-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac RELAYS 1 1 1 1 1 1 1 1 1 1 1 CONTACTS SPDT SPDT SPDT SPST SPST SPDT SPDT SPDT SPDT SPDT SPDT OVERRIDE SWITCH 1 1 2 2 NOTES # # # # SPEC PAGE 60 60 60 61 61 61 61 62 62 63 63 TRACK MOUNT DRY CONTACT INPUT RELAYS MODEL # RIBM01ZNDC · RIBM02ZNDC · RIBM013PNDC · POWER INPUT 120 Vac 208-277 Vac 120 Vac RELAYS 1 1 1 CONTACTS DPDT DPDT 3PDT OVERRIDE SWITCH = UL Listed : UL916 Energy Management; USA & Canada = UL Component Recognized : UL916 Energy Management; USA & Canada # = Time Delay (800) 888-5538 | www.functionaldevices.com NOTES SPEC PAGE 64 64 64 59 RELAYS DRY CONTACT INPUT RELAYS RIB21CDC Enclosed Relay 10 Amp SPDT, Class 2 Dry Contact Input, 120-277 Vac Power Input Blk 120 - 277 Vac Red Neutral or Other Phase CONTROL CIRCUIT Dry Contact Input Wht/Blu Wht/Red Org N/O Yel Comm Blu N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Made in USA Meets "Buy American" of ARRA 2009 RIB21CDC-RD · Red housing RIB21CDC-N4 · NEMA 4X housing, UL508 only Power Input: 50 mA @ 240 Vac Max. Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. DRY CONTACT INPUT RELAYS RIB01BDC Enclosed Relay 20 Amp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input RIB02BDC Enclosed Relay 20 Amp SPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input Blk 120 Vac Wht Neutral CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Blk 208-277 Vac Red Neutral or Other Phase CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIB01BDC) 62 mA @ 208-277 Vac (RIB02BDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. 60 Functional Devices, Inc. | American Made. American Owned. RELAYS DRY CONTACT INPUT RELAYS RIB01SBDC Enclosed Relay 20 Amp SPST-N/O + Override, Class 2 Dry Contact Input, 120 Vac Power Input RIB02SBDC Enclosed Relay 20 Amp SPST-N/O + Override, Class 2 Dry Contact Input, 208-277 Vac Power Input Blk 120 Vac Wht Neutral CONTROL CIRCUIT CLOSED OPEN AUTO Org Org Dry Contact Input Wht/Red Wht/Blu Blk 208-277 Vac Red Neutral or Other Phase CONTROL CIRCUIT CLOSED OPEN AUTO Org Org Dry Contact Input Wht/Red Wht/Blu Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIB01SBDC) 62 mA @ 208-277 Vac (RIB02SBDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. · Order Normally Closed by adding "-NC" to end of model number DRY CONTACT INPUT RELAYS RIB01SBCDC Enclosed Relay 20 Amp SPDT + Override, Class 2 Dry Contact Input, 120 Vac Power Input RIB02SBCDC Enclosed Relay 20 Amp SPDT + Override, Class 2 Dry Contact Input, 208-277 Vac Power Input Blk 120 Vac Wht Neutral CONTROL CIRCUIT Blk 208-277 Vac Red Neutral or Other Phase CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Dry Contact Input Wht/Red Wht/Blu MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIB01SBCDC) 62 mA @ 208-277 Vac (RIB02SBCDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. (800) 888-5538 | www.functionaldevices.com 61 DRY CONTACT INPUT TIME DELAY RELAYS RIBD01BDC Enclosed Delay on Make Relay 20 Amp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input RIBD02BDC Enclosed Delay on Make Relay 20 Amp SPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input Wht/Blk 120 Vac Wht/Blk Neutral CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Wht/Brn 208-277 Vac Wht/Brn CONTROL Neutral or Other Phase CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms after time delay Relay Status: Red LED On = Activated Time Delay Status: Pink LED FLASHING = Timing / Relay Deactivated Timing Mode: Delay On Make Timing Range: 6 seconds - 20 minutes Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5% Timing Repeatability: +1% Temperature Timing Variance: +1% Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIBD01BDC) 62 mA @ 208-277 Vac (RIBD02BDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to start timing. Relay will activate after timing sequence has ended. · If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. Range Selection 1234 Timing Adjustment C BD AE Only Close 1 Switch Depressed for closed Depressed for open TIMING TABLE Switch Ranges Close Dip Switch A Potentiometer Setting B C D 6s-20s 1 6s 9s 13s 16s 22s-1min15s 2 22s 36s 50s 1min4s 1min30s-5min 3 1min30s 2min10s 3min20s 4min16s 6min-20min 4 6min 9min 13min20s 17min20s E 20s 1min15s 5min 20min Dry Contact Input Load on N/O Contact Load on N/C Contact Pink LED Red LED 62 Time Delay Time Delay Delay on Make Interrupted Time Delay Interrupted Time Delay Closed Open On O On O Flashing O On O Wiring for Load on N/O Contact 120 Vac or 208-277 Vac Neutral or Other Phase Org Switched Power to Load Yel Continuous Power Wiring for Load on N/C Contact 120 Vac or 208-277 Vac Blu Switched Power to Load Neutral or Other Phase Yel Continuous Power Functional Devices, Inc. | American Made. American Owned. DRY CONTACT INPUT TIME DELAY RELAYS RIBD01BDC-DOB Enclosed Delay on Break Relay 20 Amp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input RIBD02BDC-DOB Enclosed Delay on Break Relay 20 Amp SPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input RELAYS Wht/Blk 120 Vac Wht/Blk Neutral CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Wht/Brn 208-277 Vac Wht/Brn CONTROL Neutral or Other Phase CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms after time delay Relay Status: Red LED On = Activated Time Delay Status: Pink LED FLASHING = Timing / Relay Deactivated Timing Mode: Delay On Break Timing Range: 6 seconds - 20 minutes Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5% Timing Repeatability: +1% Temperature Timing Variance: +1% Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIBD01BDC-DOB) 62 mA @ 208-277 Vac (RIBD02BDC-DOB) Notes: · Dry Contact Input Operation: Open White/Red wire and White/Blue wire to start timing. Relay will activate after timing sequence has ended. · If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. Range Selection 1234 Timing Adjustment C BD AE Only Close 1 Switch Depressed for closed Depressed for open TIMING TABLE Switch Ranges Close Dip Switch A Potentiometer Setting B C D 6s-20s 1 6s 9s 13s 16s 22s-1min15s 2 22s 36s 50s 1min4s 1min30s-5min 3 1min30s 2min10s 3min20s 4min16s 6min-20min 4 6min 9min 13min20s 17min20s E 20s 1min15s 5min 20min Dry Contact Input Load on N/O Contact Load on N/C Contact Pink LED Red LED Time Delay Time Delay Delay on Make Interrupted Time Delay Closed Open On O Wiring for Load on N/O Contact 120 Vac or 208-277 Vac Neutral or Other Phase Org Switched Power to Load Yel Continuous Power Interrupted Time Delay On O Flashing O On O Wiring for Load on N/C Contact 120 Vac or 208-277 Vac Blu Switched Power to Load Neutral or Other Phase Yel Continuous Power (800) 888-5538 | www.functionaldevices.com 63 DRY CONTACT INPUT TRACK MOUNT RELAYS RIBM01ZNDC 4.00 Track Mount Relay 30 Amp DPDT, Class 2 Dry Contact Input, 120 Vac Power Input RIBM02ZNDC 4.00 Track Mount Relay 30 Amp DPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input Dry Contact Input CONTROL CIRCUIT POWER INPUT 120 Vac Neutral N/C N/O Comm N/C N/O Comm Dry Contact Input CONTROL CIRCUIT POWER INPUT 208-277 Vac Neutral or Other Phase N/C N/O Comm N/C N/O Comm Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: Red LED On = Activated Power Status: Green LED On = Activated Dimensions: 2.875 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA @ 120 Vac 1158 VA @ 240 Vac 1109 VA @ 277 Vac 1640 VA @ 480 Vac NEMA B600 Pilot Duty Power Input: 95 mA @ 120 Vac (RIBM01ZNDC) 95 mA @ 208-277 Vac (RIBM02ZNDC) Notes: · Dry Contact Input Operation: Close dry contact to activate relay. DRY CONTACT INPUT TRACK MOUNT RELAYS RIBM013PNDC 4.00 Track Mount Relay 30 Amp 3PDT, Class 2 Dry Contact Input, 120 Vac Power Input N/C Made in USA Meets "Buy American" of ARRA 2009 DRY CONTACT INPUT CONTROL CIRCUIT POWER INPUT 120 Vac Neutral N/O Comm N/C N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Power Status: Green LED On = Activated Dimensions: 2.875 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 30 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240/277 Vac, 1 Phase 1 HP @ 120 Vac, 1Phase 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast Heavy Pilot Duty 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1109 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase 64 Functional Devices, Inc. | American Made. American Owned. Power Input: 95 mA @ 120 Vac Notes: · Dry Contact Input Operation: Close dry contact to activate relay. NETWORK COMPATIBLE RELAYS LonMark® | BACnet® | Wi-Fi | Modbus® Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Use These Devices When a More Expensive Multi-Output Controller is Too Much for the Job · UL Listed · LonWorks®,BACnet®, Wi-Fi, and Modbus® protocol · Analog input · Analog output · Binary output · Binary input · Thermistor inputs available · On-board current sensors available · Panel mount · Enclosed versions · NEMA 4X available RELAYS LONMARK® DEVICES MODEL # RIBTW2401B-LN · RIBTW2402B-LN · RIBTW2401SB-LN · RIBTW2402SB-LN · RIBMNWX2401SB-LN · RIBTWX2401SB-LN · RIBMNWX2402SB-LN · RIBTWX2402SB-LN · RIBMW24SB-LNAI · RIBTW24SB-LNAI · RIBMW24SB-LNT2 · RIBTW24SB-LNT2 · RIBMW24SB-LNT3 · RIBTW24SB-LNT3 · RELAY OUTPUT 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DRY CONTACT BINARY INPUT 1 1 1 1 1 1 1 1 1 1 ANALOG INTERNAL CURRENT PRECON® INPUT SENSOR FEEDBACK THERMISTOR INPUT · · · · 1 1 10k Type 2 10k Type 2 10k Type 3 10k Type 3 DEVICE POWER AC/DC 24 24 24 24 24 24 24 24 24 24 24 24 24 24 AC 120 208-277 120 208-277 120 120 208-277 208-277 CONTACTS SPDT SPDT SPST SPST SPST SPST SPST SPST SPST SPST SPST SPST SPST SPST OVERRIDE SWITCH NOTES SPEC PAGE 66 66 1 67 1 67 1 68 1 68 1 69 1 69 1 70 1 70 1 71 1 71 1 71 1 71 BACNET® DEVICES DRY CONTACT RELAY BINARY ANALOG ANALOG MODEL # OUTPUT INPUT INPUT OUTPUT RIBTW2401B-BC · 1 1 RIBTW2402B-BC · 1 1 RIBMNWX2401B-BC · 1 1 RIBTWX2401B-BC · 1 1 RIBMNWX2402B-BC · 1 1 RIBTWX2402B-BC · 1 1 RIBMNW24B-BCAI · 1 2 1 RIBTW24B-BCAI · 1 2 1 RIBTW24B-BCAO · 1 2 1 1 RIBMNWD12-BCDI 12 RIBMNWD12-BC 12 RIBMW24B-44-BC · 4 4 ACCUMULATOR INPUT 2 INTERNAL CURRENT SENSOR FEEDBACK · · · · PRECON® THERMISTOR INPUT 10k Type 2 or 3 10k Type 2 or 3 10k Type 2 or 3 DEVICE POWER AC/DC AC 24 120 24 208-277 24 120 24 120 24 208-277 24 208-277 24 24 24 24 24 24 CONTACTS SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT OVERRIDE SWITCH NOTES # # # # # # # # # NEW # SPEC PAGE 72 72 73 73 74 74 75 75 76 77 78 79 WI-FI DEVICES MODEL # RIBTW24B-WI-N4 · · RIBTW2401B-WIUI-N4 RELAY OUTPUT 1 1 DRY CONTACT BINARY INPUT 1 1 UNIVERSAL INPUT 2 DEVICE POWER AC/DC AC 24 24 120 CONTACTS SPDT SPDT OVERRIDE SWITCH # # NOTES NEW NEW SPEC PAGE 80 81 MODBUS® DEVICES MODEL # RIBMNW24B-MBAI · RIBTW24B-MBAI · RELAY OUTPUT 1 1 DRY CONTACT BINARY INPUT 2 2 ANALOG INPUT 1 1 INTERNAL CURRENT SENSOR FEEDBACK PRECON® THERMISTOR INPUT 10k Type 2 10k Type 2 DEVICE POWER AC/DC AC 24 24 CONTACTS SPDT SPDT OVERRIDE SWITCH # # NOTES SPEC PAGE 82 82 = UL Listed : UL916 Energy Management, USA & Canada Precon® is a registered trademark of Kele and Associates. # = Coil Side Relay Override (requires unit to be powered) (800) 888-5538 | www.functionaldevices.com 65 NETWORK COMPATIBLE RELAYS RIBTW2401B-LN LonWorks® Twisted-Pair FT-10 Network Enclosed Dual I/O Device: One Binary Output (20 Amp Relay SPDT), One Binary Input (Dry Contact Class 2); 24 Vac/dc or 120 Vac Power Input RIBTW2402B-LN LonWorks® Twisted-Pair FT-10 Network Enclosed Dual I/O Device: One Binary Output (20 Amp Relay SPDT), One Binary Input (Dry Contact Class 2); 24 Vac/dc or 208-277 Vac Power Input Service Button Service Button RELAYS 24 Vac/dc Com LON LON PINK LED = Binary Input Status GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service 24 Vac/dc Com LON LON PINK LED = Binary Input Status GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service Class 2 Dry Contact Binary Input Class 2 Dry Contact Binary Input Made in USA Meets "Buy American" of ARRA 2009 Wht/Yel Wht/Blk Blu Yel Org Neutral 120 Vac N/C Comm N/O Wht/Yel Wht/Brn Blu Yel Org Neutral or 208-277 Vac N/C Comm N/O Other Phase SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Pink LED: Binary Input Status Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 20 Amp Ballast @ 277 Vac (N/C) 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 111 mA @ 24 Vac 96 mA @ 120 Vac (RIBTW2401B-LN) 105 mA @ 208-277 Vac (RIBTW2402B-LN) 81 mA @ 24 Vdc Power Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTW2401B-LN) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTW2402B-LN) Notes: · Order with P1 option by adding "-P1" to end of model number. The P1 option is pre-programmed to allow dry contact binary input to command the relay. Contact closure on the BI will activate relay. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Transceiver Compatibility: FT3120 / FT3150, FTT-10 / FTT-10A, and LPT-10 / LPT-11 Tranceivers Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. RIBTW2401B-LN or RIBTW2402B-LN Half-Wave Device DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off Communication timer Status of Binary Input Invert status of Binary Input Max time between updates Min time between updates SNVT NAME nvi Value nvo Value Fb NondcieDOebfajeucltt nci Max Receive T nvo Value NV1 nvi Requesnt ci InveNrtV2 nvo Status nci Max Send T nci Min Send T SNVT TYPE SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm SNVT_switch SNVT_lev_disc SNVT_elapsed_tm SNVT_elapsed_tm 24 Vac 24 Vac/dc Com The relay will go to the default state when the cColomsemduLnoicoaptiAoncttuimateorr times out. Setting the timer value 24 Vac Com to zerNoowdiellOcabujesectthe communication to never time(Boinuatr.y Output) IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). Iwt oisrkreacfotemrmpoewndeer dlotsos.pItuitsathvealrueespinonnsciibMilNiatVxy1Soef nnthvdieVTaultusoeeer ntosuernesNtuhVr2ee RnvIBo Vraelu-seyFnbchronizes itself on the netthis value does not cause conflicts in NV1 nnvei Rtewqouerskt but may traffic.N(NV2o vnavlouSeta=tuNs o "heartbeat" cause many traffic collisions; High updates / no re-sychronization; value = Fenwci uDpefdaaulttes but many Low Value = Many less collisions.) updates nci Max Receive T 66 Node Object NV1 nvi Request NV2 nvo Status Closed Loop Actuator (Binary Output) NV1 nvi Value NV2 nvo Value Fb nci Default nci Max Receive T Open Loop Sensor Object (Binary Input) NV1 nvo Value nci Invert nci Max Send T nci Min Send T Closed Loop Actuator (Binary Output) Open Loop Sensor Object (Binary Input) NV1 nvi Value Functional Devices, Inc. | American Made. American Owned. NV2 nvo Value Fb NV1 nvo Value nci Default nci Invert NETWORK COMPATIBLE RELAYS RIBTW2401SB-LN LonWorks® Twisted-Pair FT-10 Network Enclosed Dual I/O Device: One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); 24 Vac/dc or 120 Vac Power Input RIBTW2402SB-LN LonWorks® Twisted-Pair FT-10 Network Enclosed Dual I/O Device: One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); 24 Vac/dc or 208-277 Vac Power Input Service Button Service Button 24 Vac/dc Com LON LON PINK LED = Binary Input Status GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service 24 Vac/dc Com LON LON PINK LED = Binary Input Status GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service RELAYS Class 2 Dry Contact Binary Input Wht/Yel Wht/Blk Neutral 120 Vac CLOSED OPEN AUTO Selectable Jumper Wire Org Org Class 2 Dry Contact Binary Input CLOSED OPEN AUTO Selectable Wht/Yel Jumper Wire Neutral or Wht/Brn Other Phase 208-277 Vac Org Org Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Pink LED: Binary Input Status Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 10 Amp Ballast @ 120/277 Vac Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 111 mA @ 24 Vac 96 mA @ 120 Vac (RIBTW2401SB-LN) 105 mA @ 208-277 Vac (RIBTW2402SB-LN) 81 mA @ 24 Vdc Power Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTW2401SB-LN) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTW2402SB-LN) Notes: · Order with P1 option by adding "-P1" to end of model number. The P1 option is pre-programmed to allow dry contact binary input to command the relay. Contact closure on the BI will activate relay. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Transceiver Compatibility: FT3120 / FT3150, FTT-10 / FTT-10A, and LPT-10 / LPT-11 Tranceivers Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off Communication timer SNVT NAME nvi Value Nnovdoe VOablujeecFtb nci Default nci Max Receive T SNVT TYPE SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm Status of Binary Input Invert status of Binary Input NV1 nvi Requestnvo ValNuVe2 nvo Status nci Invert SNVT_switch SNVT_lev_disc Max time between updates nci Max Send T SNVT_elapsed_tm RIBTW2401SB-LN or RIBTW2402SB-LN Half-Wave Device Min time between updates nci Min Send T SNVT_elapsed_tm Closed Loop Actuator 24 Vac 24 Vac/dc Com 24 Vac TtohezerNreooladwyeiwllOiclblajgueoscettothtehecodmefmauulnt isctaattieonwthoennetvheerctoimme(mBionuuanrty.icOautitopunt)timer times out. Setting the timer value Com It is recommended to put a value in nci MNVa1x nvi Value Send T to ensureNtVh2enRvoIBVarelu-esFybnchronizes itself on the net- IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection NV1 nvwnieRoterwqkuoaersfkttetrrapfofiwcN.e(VNr2loosnvsva.olIuStteiast=utshNeor"ehsepaorntbsiebailti"tyupodf tahteesu/snneciroDtroeefa-esunyltscuhrreonthizisatviaolnu;eLdooweVsanluoet cause conflicts in = Many updates between devices. Band on diode faces towards RIB(s). but may cause many traffic collisions; High value =ncFi eMwaxuRpedceaivteesTbut many less collisions.) Node Object NV1 nvi Request NV2 nvo Status Closed Loop Actuator (Binary Output) NV1 nvi Value NV2 nvo Value Fb nci Default nci Max Receive T Open Loop Sensor Object (Binary Input) NV1 nvo Value nci Invert nci Max Send T nci Min Send T Closed Loop Actuator (Binary Output) Open Loop Sensor Object (Binary Input) (800) 888-5538 | www.functionaldevices.com NV1 nvi Value NV2 nvo Value Fb NV1 nvo Value nci Invert 67 RELAYS GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service PINK LED = Current Flow NETWORK COMPATIBLE RELAY / CURRENT SENSOR COMBOS RIBMNWX2401SB-LN 2.75 Track Mount LonWorks® Twisted-Pair FT-10 Network Dual I/O Device; One Binary Output (20 Amp Relay SPST + Override); One Binary Input (Current Sensor 0.25 - 20 Amp, Relay Load Sensing), 24 Vac/dc or 120 Vac Power Input RIBTWX2401SB-LN Enclosed LonWorks® Twisted-Pair FT-10 Network Dual I/O Device; One Binary Output (20 Amp Relay SPST + Override); One Binary Input (Current Sensor 0.25 - 20 Amp, Relay Load Sensing), 24 Vac/dc or 120 Vac Power Input LON Service Button LON Open Loop Sensor Object * Internal Current Sensor Selectable Jumper Wire Com 24 Vac/dc Com 120 Vac CLOSED OPEN AUTO Not used Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Dimensions: 6.00 x 2.75 x 1.75 (RIBMNWX2401SB-LN) 7.00 x 4.28 x 2.00 with .75 NPT Nipple (RIBTWX2401SB-LN) Track Mount: MT212-6 Mounting Track Provided Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Override Switch: Yes Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. RIBMNWX2401SB-LN or RIBTWX2401SB-LN Half-Wave Device Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 10 Amp Ballast @ 120/277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 105 mA @ 120 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. Notes: · Normally Open or Normally Closed selected by yellow jumper wire. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2401SB-LN-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2401SB-LN-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2401SB-LN-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off Communication timer Status of Binary Input Invert status of Binary Input Max time between updates Min time between updates SNVT NAME nvi Value NondveoOVbajleucetFb nci Default nci Max Receive T NV1 nvi Request nvo Value NV2 nvo Status nci Invert nci Max Send T nci Min Send T SNVT TYPE SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm SNVT_switch SNVT_lev_disc SNVT_elapsed_tm SNVT_elapsed_tm 24 Vac 24 Vac/dc Com Closed Loop Actuator 24 Vac TtohezerNreooladwyeiwllOiclblajgueoscettothtehecodmefmauulnt isctaattieonwthoennetvheerctoimm(Beminoauurnyt.iOcuattpiount) timer times out. Setting the timer value Com It is recommended to put a value in nciNMVa1x Snevni VdalTueto ensurNeVt2henvRoIVBalruee-Fsbynchronizes itself on the net- IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection NV1 nvwnieRoterwqkuoaersfkttetrrapfofiwcN.e(VNr2loosnvsva.olIutSteiast=utshNeor"ehsepaorntbsiebailti"tyupodf tahteesun/scnei Droetrofeau-eslntyscuhrreonthizisatviaolnu;eLdooweVsanluoet cause conflicts in = Many updates between devices. Band on diode faces towards RIB(s). but may cause many traffic collisions; High valuen=ciFMeawx RuepcdeiaveteTs but many less collisions.) 68 Node Object NV1 nvi Request NV2 nvo Status Closed Loop Actuator (Binary Output) NV1 nvi Value NV2 nvo Value Fb nci Default nci Max Receive T * Open Loop Sensor Object (Binary Input) NV1 nvo Value nci Invert nci Max Send T nci Min Send T Closed Loop Actuator (Binary Output) * Open Loop Sensor Object (Binary Input) NV1 nvi Value NV2 FnvuonVacluteioFbnal Devices, Inc. | AmNeVr1icannvoMValuaede. American Owned. nci Default nci Max Receive T nci Invert nci Max Send T GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service PINK LED = Current Flow RELAYS NETWORK COMPATIBLE RELAY / CURRENT SENSOR COMBOS RIBMNWX2402SB-LN 2.75 Track Mount LonWorks® Twisted-Pair FT-10 Network Dual I/O Device; One Binary Output (20 Amp Relay SPST + Override); One Binary Input (Current Sensor 0.25 - 20 Amp, Relay Load Sensing), 24 Vac/dc or 208-277 Vac Power Input RIBTWX2402SB-LN Enclosed LonWorks® Twisted-Pair FT-10 Network Dual I/O Device; One Binary Output (20 Amp Relay SPST + Override); One Binary Input (Current Sensor 0.25 - 20 Amp, Relay Load Sensing), 24 Vac/dc or 208-277 Vac Power Input LON LON Com 24 Vac/dc Com 208-277 Vac Service Button Open Loop Sensor Object * Internal Current Sensor Selectable Jumper Wire CLOSED OPEN AUTO Not used Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Dimensions: 6.00 x 2.75 x 1.75 (RIBMNWX2402SB-LN) 7.00 x 4.28 x 2.00 with .75 NPT Nipple (RIBTWX2402SB-LN) Track Mount: MT212-6 Mounting Track Provided Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 10 Amp Ballast @ 120/277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 120 mA @ 208-277 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. Notes: · Normally Open or Normally Closed selected by yellow jumper wire. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2402SB-LN-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2402SB-LN-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2402SB-LN-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off SNVT NAME nvi Value Node ObnjevcotValue Fb nci Default SNVT TYPE SNVT_switch SNVT_switch SNVT_switch Communication timer Status of Binary Input nci Max Receive T NV1 nvi Request NnVv2o VnavlouSetatus SNVT_elapsed_tm SNVT_switch Invert status of Binary Input nci Invert SNVT_lev_disc Max time between updates nci Max Send T SNVT_elapsed_tm RIBMNWX2402SB-LN or RIBTWX2402SB-LN Half-Wave Device Min time between updates nci Min Send T SNVT_elapsed_tm Closed Loop Actuator 24 Vac 24 Vac/dc Com 24 Vac NoThdee rOeblajyecwtill go to the default state when t(hBeincaroymOmutpuunti)cation timer times out. Setting the timer value to zero will cause the communication to never time out. Com It is recommended to put a valueNinV1ncinMvi aVaxluSeend T toNeVn2snuvroeVtahluee Fb RIB re-synchronizes itself on the net- ^^ Option 2: IN4004 NV1 Add diode on 24 Vac power (Com) interconnection nvi Requewnsteotrwk oarfkteNtrrVap2fofiwncv.eo(NrSltooatsvussa. lIut eis=thNeor"ehsepaorntbsiebailti"tyupondfctai hDteeesfua/usnletrotroe-esnyscuhrreonthizisatviaolnu;eLdooweVsanluoet cause conflicts in = Many updates between devices. Band on diode faces towards RIB(s). but may cause many traffic collisions; HighnvciaMluaex =ReFceeiwveuTpdates but many less collisions.) Node Object NV1 nvi Request NV2 nvo Status Closed Loop Actuator (Binary Output) NV1 nvi Value NV2 nvo Value Fb nci Default nci Max Receive T * Open Loop Sensor Object (Binary Input) NV1 nvo Value nci Invert nci Max Send T nci Min Send T Closed Loop Actuator (Binary Output) NV1 nvi Value NV2 nvo Value Fb * Open Loop Sensor Object (Binary Input) (800) 888-5538 | www.functionaldevices.com NV1 nvo Value 69 NETWORK COMPATIBLE RELAY / CURRENT SENSOR COMBOS RIBMW24SB-LNAI 4.00 Track Mount LonWorks® Twisted-Pair FT-10 Network Three I/O Device; One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); One Analog Input (0-5Vdc / 0-10 Vdc); 24 Vac/dc Power Input RIBTW24SB-LNAI Enclosed LonWorks® Twisted-Pair FT-10 Network Enclosed Three I/O Device; One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); One Analog Input (0-5Vdc / 0-10 Vdc); 24 Vac/dc Power Input. + 5V (typically not used) AI Com Analog-In 1 2 OPEN Class 2 Dry Contact Binary Input + 5V (typically not used) AI Com Analog-In 1 2 OPEN RELAYS Class 2 Dry Contact Binary Input Service Button YELLOW LED = Service PINK LED = Binary Input Status RED LED = Relay Activated GREEN LED = Network Status 5 V 10 V CLOSED OPEN AUTO Service Button YELLOW LED = Service PINK LED = Binary Input Status RED LED = Relay Activated GREEN LED = Network Status 5 V 10 V CLOSED OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 LON LON 24 Vac/dc Com LON LON 24 Vac/dc Com Selectable Jumper Wire Selectable Jumper Wire SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Pink LED: Binary Input Status Dimensions: 4.00 x 4.00 x 1.50 (RIBMW24SB-LNAI) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTW24SB-LNAI) Track Mount: MT4-4 Mounting Track Provided Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Override Switch: Yes Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Transceiver Compatibility: FT3120 / FT3150, FTT-10 / FTT-10A, and LPT-10 / LPT-11 Tranceivers Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object 0520 Analog Input Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. Closed Loop Actuator (BinaNryoOduetpOubt)ject OpeCnloLsoeodpLoSoenpsAocrtOuabtjoecr t ((BBiinnaarryy IOnputupt)ut) vo Status NV1 nvi Value NV2 nvo Value Fb NV1 nvi Request NV2 nvo Status nci Default nci Max Receive T NV1 nvi Value NNVV12 nnvvooVVaalulueeFb nci Invert nci nMcai xDSeefanudltT nnccii MMainx SReencedivTe T or OpeCnloLsoeodpLSoeonpsAorctOubajteocrt Open Loop Sensor Object t (B(BininaarryyInOpuutpt)ut) Analo(BginIanrpy uIntput) o Value Fb V2 nvo Status NV1 nvi Value NVN1V2 nnvvoo VVaalluuee Fb nci Invert nci MncaixDSeefnaudlTt nnccii MMianxSReencdeiTve T NV1 nvo NV1 AnnavloogValue nci MaxnSceinIndvTe1rt nci MninciSMenadx STe1nd T nci Mncini MDienltSaend T Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 10 Amp Ballast @ 120/277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 111 mA @ 24 Vac 81 mA @ 24 Vdc Power Input: 24 Vac/dc ; 50-60 Hz * Notes: · Order with P1 option by adding "-P1" to end of model number. The P1 option is pre-programmed to allow dry contact binary input to command the relay. Contact closure on the BI will activate relay. · Normally Open or Normally Closed selected by yellow jumper wire. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24SB-LNAI-N4) · Close DIP switch 1 for 0-5 Vdc Analog Input. Close DIP switch 2 for 0-10 Vdc Analog Input. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ · See page 71 for -LNT2 or -LNT3 models if using a thermistor. If using a thermistor on the Analog Input, set DIP switches to the 0-5 Vdc setting. A look-up table must also be made. DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off Communication timer Status of Binary Input Invert sOtapteunsLoofoBpinSaernysoInrpOubtject Max timeAbneatlw(oBgieneaInrnypuIunpptudta) tes Min time between updates Value of Analog-In NV1NVn1vo AnnvaoloVgalue Max time nbcei MtwaxenSeceinnIndAvTen1rat log updates Min time bnceitMwnicnei SeMenanxdASTne1nadloTg updates nci nMciinMDienltSaend T Min change in Analog before updates SNVT NAME nvi Value nvo Value Fb nci Default nci Max Receive T nvo Value nci Invert AnalongcIinMpuatx Send T nci Min Send T nvoNVA1nanvloo gAnalog nci ManxcSieMndaTx1 Send T1 nci MinnSceinMd iTn1 Send T1 nci MinnDceilMta in Delta SNVT TYPE SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm SNVT_switch SNVT_lev_disc SNVT_elapsed_tm SNVT_elapsed_tm SNVT_lev_percent SNVT_elapsed_tm SNVT_elapsed_tm SNVT_lev_percent The relay will go to the default state when the communication timer times out. Setting the timer value to zero will cAanuasloegtIhnepuctommunication to never time out. Iwt oisrkreacfotemrmpoewndeer dlotsoNsV.p1ItuintsvoatAhvneaalolrugeespinonnsciibMiliatxy Send T to ensure the of the user to ensure RIB re-synchronizes itself on the netthis value does not cause conflicts in network trafnnficccii MM. (ianNxSSoeennvddaTT11lue = No "heartbeat" updates / no re-sychronization; Low Value = Many updates but may causnecimMinanDeyltatraffic collisions; High value = Few updates but many less collisions.) 0-5Vdc or 0-10 Vdc Temperature, Humidity, Pressure Transducer 70 AI AI Com Analog 10K Input 24 Vac RIBMW24SB-LNAI or RIBTW24SB-LNAI 24 Vac/dc Com Half-Wave Device 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). Functional Devices, Inc. | American Made. American Owned. RELAYS NETWORK COMPATIBLE RELAYS RIBMW24SB-LNT2 4.00 Track Mount LonWorks® Twisted-Pair FT-10 Network Three I/O Device; One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); Precon® Type 2 Thermistor Input; 24 Vac/dc Power Input Connect Precon® 10K @ 77 (25), Type 2, Model 24 (or equivalent) to Thermistor terminals: +5 Vdc and Analog-In. Set DIP switch to 5V (see below.) RIBTW24SB-LNT2 Enclosed LonWorks® Twisted-Pair FT-10 Network Three I/O Device; One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); Precon® Type 2 Thermistor Input; 24 Vac/dc Power Input Connect Precon® 10K @ 77 (25), Type 2, Model 24 (or equivalent) to Thermistor terminals: +5 Vdc and Analog-In. Set DIP switch to 5V (see below.) Class 2 Dry Contact Binary Input + 5V AI Com (typically not used) Analog-In 1 2 OPEN Class 2 Dry Contact Binary Input + 5V AI Com (typically not used) Analog-In 1 2 OPEN LON LON 24 Vac/dc Com LON LON 24 Vac/dc Com Service Button YELLOW LED = Service PINK LED = Binary Input Status RED LED = Relay Activated GREEN LED = Network Status 5 V 10 V CLOSED OPEN AUTO Selectable Jumper Wire Service Button YELLOW LED = Service PINK LED = Binary Input Status RED LED = Relay Activated GREEN LED = Network Status 5 V 10 V CLOSED OPEN AUTO Selectable Jumper Wire Made in USA Meets "Buy American" of ARRA 2009 THERMISTOR INPUT SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Pink LED: Binary Input Status Dimensions: 4.00 x 4.00 x 1.50 (RIBMW24SB-LNT2) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTW24SB-LNT2) Track Mount: MT4-4 Mounting Track Provided Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Override Switch: Yes Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Transceiver Compatibility: FT3120 / FT3150, FTT-10 / FTT-10A, and LPT-10 / LPT-11 Tranceivers Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object 1040 Temperature Sensor Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. 24 Vac RIBMW24SB-LNT2, RIBTW24SB-LNT2, RIBMW24SB-LNT3 or RIBTW24SB-LNT3 24 Vac/dc Com Half-Wave Device 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 10 Amp Ballast @ 120/277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 111 mA @ 24 Vac 81 mA @ 24 Vdc Power Input: 24 Vac/dc ; 50/60 Hz ^ Notes: · Order with P1 option by adding "-P1" to end of model number. The P1 option is pre-programmed to allow dry contact binary input to command the relay. Contact closure on the BI will activate relay. · Normally Open or Normally Closed selected by yellow jumper wire. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24SB-LNT2-N4) · -35 to 100°C range in one degree steps. -36°C indicates below range, 101°C indicates above range. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ · Can be used with Precon® Type 3 Thermistor Input. Use suffix "-LNT3" instead of "LNT2" when ordering. Thermistor not included. DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off Communication timer Status of Digital-In Invert status of Digital-In Max time between updates Min time between updates T2 Thermistor input * Max time between Temperature updates Min time between Temperature updates Min change in Temperature before updates SNVT NAME nvi Value nvo Value Fb nci Default nci Max Receive T nvo Value nci Invert nci Max Send T nci Min Send T nvo HVACTemp nci Max Send T1 nci Min Send T1 nci Min Delta SNVT TYPE SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm SNVT_switch SNVT_lev_disc SNVT_elapsed_tm SNVT_elapsed_tm SNVT_temp_p SNVT_elapsed_tm SNVT_elapsed_tm SNVT_temp_p The relay will go to the default state when the communication timer times out. Setting the timer value to zero will cause the communication to never time out. It is recommended to put a value in nci Max Send T to ensure the RIB re-synchronizes itself on the network after power loss. It is the responsibility of the user to ensure this value does not cause conflicts in network traffic. (No value = No "heartbeat" updates / no re-sychronization; Low Value = Many updates but may cause many traffic collisions; High value = Few updates but many less collisions.) Object NV2 nvo Status Closed Loop Actuator N(oBidnearOy ObujetpcutNt)ode Object ClOospeednLLooooppCASlcoetsnuesadotroLOroobpjeActctuator (Binar(yBiOnuartypNuInto)p(dBuietn)aOrybOjeuctpt ut) Open LooCploSOseenpdseonLroLOoopbojpAecSteunastor Object * Te(mBinpaeryraI(ntBupinuraet)ryS(eOBniunstaporuyrtI)nput) Open Loop Sensor Object * Temperatur*eT(SeBeimnnapsryeoIrnaptuutr)e Sensor NV1 nvi Value NV2 nvo Value Fb NV1 NV1 nvi RequesNt V1 nvi RNeVq2uesntvo StatusNV2 nvo Status nci Default nci Max Receive T nvi ValueNV1 nvNi VVa2luNneVvo1 ValnuveoFNVbaVlu2envo Value Fb NV1 nvni RcieIqnuveesrtt NV2 nvo Status ncinDcieMfaauxltSendnTci Default nci ManxcRi MecienivSeennTcidMTax Receive T NV1 nvi ValueNNV1V1 nnvvoNoHVVVa2AluCneNTveoVmV1paluenvFobValue ncnicMi IanxveSretndT1 nci Invert nncicMi MaixnSSeennndcdiTDTn1ecfiaMulatx Send T ncni MciiMnniSnceiDnMdealTtxanRceicMeiivneSTend T NV1 nvo HVANCVTe1NmVp1nvnovoVHalVuAeCTemp nci Max SendT1nnccii IMnvaexrStendT1 nci Min SendnTc1inMciaMx iSneSnednTd T1 nci Min Delntaci Mncini MSeinndDeTlta (800) 888-5538 | www.functionaldevices.com * Temperature Sensor NV1 nvo HVACTemp nci Max SendT1 nci Min Send T1 nci Min Delta 71 RELAYS Dry Contact Binary Input REF A() B(+) MSB LSB Baud Rate Relay Override Dry Contact Binary Input REF A() B(+) MSB LSB Baud Rate Relay Override NETWORK COMPATIBLE RELAYS RIBTW2401B-BC Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); One Binary Input (Dry Contact, Class 2); 24 Vac/dc or 120 Vac Power Input, Optional End of Line Resistor (EOL) Included. RIBTW2402B-BC Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); One Binary Input (Dry Contact, Class 2); 24 Vac/dc or 208-277 Vac Power Input, Optional End of Line Resistor (EOL) Included. } } } } MSTP 0 1 1 2 3 4 5 6 7 8 9 10 11 12 24 Vac/dc Common MS/TP ADDRESS Connect Jumper for EOL. Disconnect for no terminating resistor. MSTP 0 1 1 2 3 4 5 6 7 8 9 10 11 12 24 Vac/dc Common MS/TP ADDRESS Connect Jumper for EOL. Disconnect for no terminating resistor. Made in USA Meets "Buy American" of ARRA 2009 Wht/Yel Wht/Blk Blu Yel Org Neutral 120 Vac N/C Comm N/O Wht/Yel Wht/Brn Blu Yel Org Neutral 208-277 Vac N/C Comm N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Communication Red LED: Relay Status Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac 96 mA @ 120 Vac (RIBTW2401B-BC) 121 mA @ 208-277 Vac (RIBTW2402B-BC) Power Input: 24 Vac/dc ; 120 Vac ; 50/60 Hz (RIBTW2401B-BC) 24 Vac/dc ; 208-277 Vac ; 50/60 Hz (RIBTW2402B-BC) Notes: · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. http://www.functionaldevices.com/pdf/ pics/RIBTW240xB-BC_PICS.pdf Or scan QR code with your smart phone. DIP SWITCHES* BAUD RATE DIP SWITCHES* RELAY STATE** 8 9 10 11 12 0 0 0 9600 1 0 Auto 0 0 1 19200 X 1 Override on 0 1 0 38400 0 0 Override off 0 1 1 57600 * 0 = Open ; 1 = Closed 1 0 0 76800 ** Device must be powered for override 1 0 1 115200 All other combinations=9600 baud · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBTW2401B-BC or RIBTW2402B-BC Half-Wave Device 24 Vac 24 Vac/dc Com 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). 72 Functional Devices, Inc. | American Made. American Owned. NETWORK COMPATIBLE RELAY / CURRENT SENSOR COMBOS RIBMNWX2401B-BC 2.75 Track Mount BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (One Current Sensor 0.25 - 20 Amp, Relay Load Sensing & One Dry Contact Binary Input), 24 Vac/dc or 120 Vac Power Input, Optional End of Line Resistor (EOL) Included. RIBTWX2401B-BC Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (One Current Sensor 0.25 - 20 Amp, Relay Load Sensing & One Dry Contact Binary Input), 24 Vac/dc or 120 Vac Power Input, Optional End of Line Resistor (EOL) Included. } 1 2 3 4 5 6 7 8 9 10 11 12 1 0 Relay Override Baud Rate LSB MSB MS/TP ADDRESS Dry Contact Binary Input } } A() MSTP B(+) REF Red LED=Relay Status Green LED=Network Communication Pink LED=Current Sensor Status Pink LED=Binary Input Status Internal Current Sensor Contacts COM N/O N/C High Voltage } Power Input Low Voltage } Power Input Connect Jumper for EOL. Disconnect for no terminating resistor. Made in USA Meets "Buy American" of ARRA 2009 RELAYS Neutral 120 Vac 24 Vac/dc Comm SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00 x 2.75 x 1.75 (RIBMNWX2401B-BC) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTWX2401B-BC) Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 24 Vac/dc ; 120 Vac ; 50/60 Hz Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 105 mA @ 120 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 All other combinations=9600 baud BAUD RATE 9600 19200 38400 57600 76800 115200 DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBMNWX2401B-BC or RIBTWX2401B-BC Half-Wave Device Notes: · Device can be powered by either 24 Vac/dc or 120 Vac, but not both. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2401B-BC-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2401B-BC-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2401B-BC-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. http://www.functionaldevices.com/pdf/pics/ RIBxWX240xB-BC_PICS.pdf Or scan QR code with your smart phone. 24 Vac 24 Vac/dc Com 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). (800) 888-5538 | www.functionaldevices.com 73 NETWORK COMPATIBLE RELAY / CURRENT SENSOR COMBOS RIBMNWX2402B-BC 2.75 Track Mount BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (One Current Sensor 0.25 - 20 Amp, Relay Load Sensing & One Dry Contact Binary Input), 24 Vac/dc or 208-277 Vac Power Input, Optional End of Line Resistor (EOL) Included. RIBTWX2402B-BC Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (One Current Sensor 0.25 - 20 Amp, Relay Load Sensing & One Dry Contact Binary Input), 24 Vac/dc or 208-277 Vac Power Input, Optional End of Line Resistor (EOL) Included. } 1 2 3 4 5 6 7 8 9 10 11 12 1 0 Relay Override Baud Rate LSB MSB MS/TP ADDRESS Dry Contact Binary Input } } A() MSTP B(+) REF Red LED=Relay Status Green LED=Network Communication Pink LED=Current Sensor Status Pink LED=Binary Input Status Internal Current Sensor Contacts COM N/O N/C High Voltage } Power Input Low Voltage } Power Input Connect Jumper for EOL. Disconnect for no terminating resistor. Made in USA Meets "Buy American" of ARRA 2009 RELAYS Neutral 208-277 Vac 24 Vac/dc Comm SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00 x 2.75 x 1.75 (RIBMNWX2402B-BC) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTWX2402B-BC) Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 24 Vac/dc ; 208-277 Vac ; 50/60 Hz Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 120 mA @ 208-277 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 All other combinations=9600 baud BAUD RATE 9600 19200 38400 57600 76800 115200 DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBMNWX2402B-BC or RIBTWX2402B-BC Half-Wave Device Notes: · Device can be powered by either 24 Vac/dc or 208-277 Vac, but not both. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2402B-BC-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2402B-BC-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2402B-BC-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. http://www.functionaldevices.com/pdf/pics/ RIBxWX240xB-BC_PICS.pdf Or scan QR code with your smart phone. 74 24 Vac 24 Vac/dc Com 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). Functional Devices, Inc. | American Made. American Owned. NETWORK COMPATIBLE RELAYS RIBMNW24B-BCAI 2.75" Track Mount BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (Dry Contact, Class 2); One Analog Input (T2/T3 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included. RIBTW24B-BCAI Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (Dry Contact, Class 2); One Analog Input (T2/T3 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included. Made in USA Meets "Buy American" of ARRA 2009 RELAYS Green LED=Network Status Red LED=Relay Status Pink LED=BI 1 Status Pink LED=BI 2 Status BI 1 COM BI 1 BI 2 COM BI 2 5 V 10 V 1 2 A() B(+) REF MS/TP ^*See EOL resistor jumper. 1 0 Relay Control OPEN AI Voltage ^To select AI for Thermistor T2 or T3 input, install jumper. Select Switch ^* Connect Jumper for EOL. Disconnect for no terminating resistor. 1 2 3 4 5 6 7 8 9 10 11 12 Baud Rate LSB MS/TP ADDRESS MSB Both jumpers installed from factory. Move one to Thermistor-Input-Select^ for T2 or T3 Thermistor Input, otherwise leave both on for 5V or 10V Analog In. Connect Analog In between AI and AI common. Connect Thermistor between AI and Thermistor +5V. O O O On On O On On Not de ned T2 Thermistor T3 Thermistor Analog In 5V or 10V Type Analog AI AI COM Therm. +5V Analog In (Close only one) SW1 Closed 5 V SW2 Open 10 V SW1 Open SW2 Closed Thermistor T2 or T3 input, use 5 V selection Contacts Relay N/C } COM 24 Vac/dc Common N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.25 x 2.75 x 1.75 (RIBMNW24B-BCAI) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTW24B-BCAI) Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac Notes: · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24B-BCAI-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTW24B-BCAI-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTW24B-BCAI-N4-GY) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. Units default to 95 (no units). · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below.^^ · PIC Statement available on website. http://www.functionaldevices.com/pdf/ pics/BACnet-BCAI_PICS.pdf Or scan QR code with your smart phone. BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Dry contact binary input), AI 1 (Analog input) · Device Instance changed via Object Identifier Property of Device Object DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 DIP SWITCHES* 11 12 1 0 X 1 0 0 RELAY STATE** Auto Override on Override off * 0 = Open ; 1 = Closed ** Device must be powered for override All other combinations=9600 baud · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included. · For both T2 and T3, MIN_PRES_VAL must be set to -36 (real value) and MAX_PRES_VAL must be set to 66.3 (real value) for Celcius. For Fahrenheit, MIN_PRES_VAL must be set to -32.8 (real value) and MAX_PRES_VAL must be set to 151.34 (real value). · -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps 24 Vac RIBMNW24B-BCAI or RIBTW24B-BCAI 24 Vac/dc Com Half-Wave Device 24 Vac Com ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). IN4004 (800) 888-5538 | www.functionaldevices.com 75 NETWORK COMPATIBLE RELAY RIBTW24B-BCAO Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); One Binary Input (Dry Contact, Class 2); One Analog Output (0-5 Vdc, 0-10 Vdc, or 4-20 mA), One Analog Input (T2/T3 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included. Thermistor Select Made in USA Meets "Buy American" of ARRA 2009 BI COM B I Analog Output () 4-20 mA (+) Analog Output () 0-5 Vdc 0-10 Vdc (+) 24 Vac/dc Power Therm. +5V AI COM AI REF LSB B(+) A() RELAYS MS/TP RELAY CONTROL 1 2 3 4 5 6 7 8 9 10 11 12 MSB MS/TP ADDRESS BAUD RATE J1: Jumper for EOL resistor Green LED=Network Status J2 J3 Analog In ON ON T3 Thermistor ON OFF T2 Thermistor OFF ON Not de ned OFF OFF 10 V 5 V 1 2 OPEN AI Voltage Select Switch Red LED=Relay Status J5: Install for 0-10 V Relay Contacts Pink LED=BI Status N/O N/C COM Dry Contact Binary Input Shown With Cover } SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Relay Activated Binary Input Status: Pink LED On = Activated Dimensions: 4.28 x 7.00 x 2.00 with .75 NPT Nipple Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Gold Flash: No Relay Override: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Magnetic Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 176 mA @ 24 Vac 150 mA @ 24 Vdc Notes: · Use a separate 24 Vac transformer, or an isolated 24 Vdc power supply to power-up this product. · Complete Installation Instructions: Bulletin B1756 available on website. www.functionaldevices.com/pdf/bulletins/ B1756_393218.pdf · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included. · -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps BACnet® Details: · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), AI 1 (Analog input), AO 1 (Analog output) · PIC Statement available on website. http://www.functionaldevices.com/pdf/ pics/RIBTW24B-BCAO_PICS.pdf Or scan QR code with your smart phone. · Addressing Specifications: Bulletin B2028 available on website. www.functionaldevices.com/pdf/bulletins/B2028_393243.pdf Analog Output Voltage (0-5 Vdc; 0-10 Vdc) Analog Output Current (4-20 mA) ANALOG OUTPUT ACCURACY AS A FUNCTION OF OUTPUT SPAN (USING STANDARD CONDITIONS *) Span 20% - 100% Span 10% - 100% Span 0% - 100% +/- 2% error +/- 5% error +/- 11% error +/- 2% error +/- 3% error +/- 12% error * Standard Conditions: Power Supply Input: 22 Vac/dc to 28 Vac/dc ; Loop Resistance (Analog Output 4-20 mA Loop): 530 Ohms max. Load Resistance [Analog Output Voltage (0-5 Vdc, 0-10 Vdc)]: 10 K Ohms min. ; Ambient Temperature: -30 to 140° F 0-5Vdc or 0-10 Vdc Temperature, Humidity, Pressure Transducer 76 AI AI Com Analog 10K Input RIBTW24B-BCAO Half-Wave Device 24 Vac 24 Vac/dc Com 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). Functional Devices, Inc. | American Made. American Owned. RELAYS NETWORK COMPATIBLE DEVICE RIBMNWD12-BCDI 2.75 Track Mount BACnet® MS/TP Network 12 Binary Input Device; Optional End of Line Resistor (EOL) Included. } } MSTP 24 Vac/dc A() B(+) REF BI 1 BI 2 BI 3 BI 4 BI 5 BI 6 +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM Made in USA Meets "Buy American" of ARRA 2009 Green LED = Network Communication Red LED = Power } } } } } } 1 0 Not Used Baud Rate LSB Pink LED = Digital Input Status Connect Jumper for Dry Contact Operation. Disconnect for voltage input operation. 1 2 3 4 5 6 7 8 9 10 MS/TP ADDRESS Connect Jumper for EOL. MSB Disconnect for no terminating resistor. COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V } } } } } } BI 12 BI 11 BI 10 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Green LED: Network Communication Red LED: ON = Power Present Dimensions: 5.85 x 2.75 x 1.75 Track Mount: MT212-6 Mounting Track Provided Approvals: CE, RoHS Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Band Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) BI 9 BI 8 BI 7 Power Input Ratings: 41 mA @ 24 Vdc 53 mA @ 24 Vac Binary Input Ratings: Dry Contact: 3 mA @ 30 Vdc max. Voltage Input: 12 mA @ 25 Vac/dc max. BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Device Instance changed via Object Identifier Property of Device Object · Full wave rectified · Objects included in device are: BI 1 (Binary input) BI 7 (Binary input) BI 2 (Binary input) BI 8 (Binary input) BI 3 (Binary input) BI 9 (Binary input) BI 4 (Binary input) BI 10 (Binary input) BI 5 (Binary input) BI 11 (Binary input) BI 6 (Binary input) BI 12 (Binary input) · PIC Statement available on website. http://www.functionaldevices.com/pdf/pics/ RIBMNWD12-BCDI_PICS.pdf Or scan QR code with your smart phone. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 * 0 = Open ; 1 = Closed All other combinations=9600 baud Example of Dry Contact Input Operation Dry Contact N/C +V Vin COM Example of Voltage Input Operation Voltage Source + +V Vin COM Jumper Connected Jumper Disconnected (800) 888-5538 | www.functionaldevices.com 77 RELAYS NETWORK COMPATIBLE DEVICE RIBMNWD12-BC 2.75 Track Mount BACnet® MS/TP Network 12 Binary Input Device (With Accumulators); Optional End of Line Resistor (EOL) Included. } } MSTP 24 Vac/dc A() B(+) REF BI 1 / ACC 1 BI 2 / ACC 2 BI 3 BI 4 BI 5 BI 6 +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM Made in USA Meets "Buy American" of ARRA 2009 Green LED = Network Communication Red LED = Power } } } } } } 1 0 Not Used Baud Rate LSB Pink LED = Digital Input Status Connect Jumper for Dry Contact Operation. Disconnect for voltage input operation. 1 2 3 4 5 6 7 8 9 10 MS/TP ADDRESS MSB Connect Jumper for EOL. Disconnect for no terminating resistor. } } } } } } COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V BI 12 BI 11 BI 10 BI 9 BI 8 BI 7 TWO (ACCUMULATOR) INPUTS CAN BE USED FOR POWER MONITORING OR OTHER PULSE COUNTING APPLICATION. SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Green LED: Network Communication Red LED: ON = Power Present Dimensions: 5.85 x 2.75 x 1.75 Track Mount: MT212-6 Mounting Track Provided Approvals: CE, RoHS Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Power Input Ratings: 41 mA @ 24 Vdc 53 mA @ 24 Vac Max. Accumulator Frequency: 50 Hz Binary Input Ratings: Dry Contact: 3 mA @ 30 Vdc max. Voltage Input: 12 mA @ 25 Vac/dc max. BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Device Instance changed via Object Identifier Property of Device Object · Objects included in device are: } BI 1 (Binary input) Use Same ACC 1 (Accumulator) Physical Input } BI 2 (Binary input) Use Same ACC 2 (Accumulator) Physical Input BI 3 (Binary input) BI 4 (Binary input) BI 5 (Binary input) BI 6 (Binary input) BI 7 (Binary input) BI 8 (Binary input) BI 9 (Binary input) BI 10 (Binary input) BI 11 (Binary input) BI 12 (Binary input) · PIC Statement available on website. http://www.functionaldevices.com/pdf/pics/ RIBMNWD12-BC_PICS.pdf Or scan QR code with your smart phone. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 * 0 = Open ; 1 = Closed All other combinations=9600 baud Example of Dry Contact Input Operation Dry Contact N/C +V Vin COM Jumper Connected Example of Voltage Input Operation Voltage Source + +V Vin COM Jumper Disconnected 78 Functional Devices, Inc. | American Made. American Owned. NETWORK COMPATIBLE RELAY RIBMW24B-44-BC 4.00 Track Mount BACnet® MS/TP Network Relay Device; Four Binary Outputs (20 Amp Relay SPDT + Override); Four Binary Inputs (Dry Contact Binary Inputs), 24 Vac/dc Power Input, Optional End of Line Resistor (EOL) Included. DIP 1 DIP 2 REF B(+) A() 1 2 3 4 5 6 7 8 9 10 12345678 1 0 Baud Rate LSB MSB MSTP Relay 1 Contacts Relay 2 Contacts MS/TP ADDRESS BO1 BO2 RELAY OVERRIDE Connect Jumper Red LEDs BO3 BO4 for terminating resistor. Disconnect for no Network Status terminating resistor. Green LED Pink LEDs BI1 BI2 BI3 BI4 Relay 3 Contacts Relay 4 Contacts Power Input BO1 COM BO1 N/O BO1 N/C BO2 COM BO2 N/O BO2 N/C Made in USA Meets "Buy American" of ARRA 2009 RELAYS BO3 N/C BO3 N/O BO3 COM BO4 N/C BO4 N/O BO4 COM BI1 COM BI1 BI2 COM BI2 BI3 COM BI3 BI4 COM BI4 24 Vac/dc Comm SPECIFICATIONS # Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00 L x 4.27 W x 1.34 H Track Mount: MT4-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (Dip Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 24 Vac : 400 mA 24 Vdc : 190 mA NEED AN ENCLOSURE? ORDER MODEL MH1210 (PAGE 142) NEED A POWER SUPPLY AND AN ENCLOSURE? ORDER MODEL CTRL-PS (PAGE 113) & AT4-8 (PAGE 152) BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique) · This model utilizes: BO1, BO2, BO3, BO4, (Relay outputs), BI1, BI2, BI3, BI4 (Dry contact inputs) · Device Instance changed via Object Identifier Property of Device Object · Each unit is 1/8 unit load · PIC Statement available on website. http://www.functionaldevices.com/pdf/ pics/RIBMW24B-44-BC_PICS.pdf Or scan QR code with your smart phone. DIP 1 DIP 2 DIP Switches 1-7 8 9 10 0 0 0 0 0 1 See Bulletin B1082 for 0 1 0 full MS/TP 0 1 1 Addressing 1 0 0 1 0 1 All other combinations=9600 baud Baud Rate 9600 19200 38400 57600 76800 115200 · Dry contact digital input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. Relay BO1 BO2 BO3 BO4 Relay State** Auto ON OFF Auto ON OFF Auto ON OFF Auto ON OFF 1 2 1 X X X 0 X X 1 X X X 0 X X X X X X X X X X X X DIP Switches* 3 4 5 6 X X 0 X X X 1 X X X 0 X X X X 0 X X X 1 X X X 0 1 X X X X X X X 0 X X X X 1 X X X X X X X 0 X X 7 8 X X X X X X X X X X X X 0 X 1 X 0 X X 0 X 1 X 0 * 0 = Open ; 1 = Closed ** Device must be powered for override (800) 888-5538 | www.functionaldevices.com 79 RELAYS SW 1 SW 2 Pink LED = BI Status Green LED = Ad-Hoc Status Yellow LED = Infrastructure Status Green LED = Device Status Red LED = Relay Status BI COM BI 24 Vac/dc Common NETWORK COMPATIBLE RELAY RIBTW24B-WI-N4 Enclosed Wifi IEEE 802.11 b/g Network Enclosed I/O Device: One Discrete Output (20 Amp Relay SPDT + Override), One Discrete Input (Dry Contact, Class 2); 24 Vac/dc DIP Switch CLOSED X 12 OPEN Relay State AUTO Override ON Override OFF RESET to Factory Defaults Pushbutton (Activate with insulated tool) Relay Contacts N/C N/O COM Shown With Cover Code Version 4.0.1 Made in USA Meets "Buy American" of ARRA 2009 Wi-Fi RIBTM SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Operate Time: 18ms Pink LED: Digital Input Status Green LED: Wifi Ad-Hoc Status Yellow LED: Wifi Infrastructure Status Green LED: Device Status Red LED: Relay Status Dimensions: 4.28 x 7.00 x 2.00 with .75 NPT Nipple Approvals: UL Listed, UL916, C-UL FCC, CE, RoHS, Wifi Certified ASD Device Housing Rating: UL Accepted for Use in Plenum, NEMA 4 Gold Flash: No Relay Override Switch: DIP Switch Control Wifi: IEEE 802.11 b/g/n Compatible, (G) 54 Mbps Data Rate 95 dBm Min. Sensitivity +16 dBm Max Output Power Currently Unsecured Connection in Ad-Hoc (WPA-PSK or WPA-2-PSK Available) Supports PING and ARP DSSS Modulation Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 200 mA Max @ 24 Vac 200 mA Max @ 24 Vdc Available TCP/IP Settings: · IP Address (Static) · Port Number · Subnet Mask · Gateway Address · Ad-Hoc mode · Infrastructure mode · Scan for wireless networks Device Settings: · Local Override · Reset to Network Defaults Pushbutton Power Input: 24 Vac = Terminal Strip (20 Vac min. ; 28 Vac max.) 24 Vdc = Terminal Strip (24 Vdc min. ; 28 Vdc max.) Device Settings by Network: · Power up default relay state · Host name and location labels · Relay bound to digital input · Setup instructions available on website. http://www.functionaldevices.com/pdf/ bulletins/B1802_393224.pdf Or scan QR code with your smart phone. 80 Functional Devices, Inc. | American Made. American Owned. RELAYS NETWORK COMPATIBLE RELAY RIBTW2401B-WIUI-N4 Wifi IEEE 802.11 b/g Network Enclosed I/O Device: One Discrete Output (20 Amp Relay SPDT + Override), One Discrete Input (Dry Contact, Class 2); Two Universal Inputs; 24 Vac/dc, 120 Vac Power AUTO OFF ON Relay Operation Universal Input 1 Universal Input 2 RESET to Factory Defaults Pushbutton + 5V UI1 COM UI1 420 + 5V UI2 COM UI2 420 COM 24Vac 24Vdc 24V Optional Power Input SW 1 X SW 2 (Activate with insulated tool) COM DI General Purpose Dry Contact Input Term A: (Not used) Term A: 120 Vac Term B: (Not used) Term C: Neut 120 Vac Optional Power Input COM N/C N/O Relay Contacts SPECIFICATIONS Pink LED = DI Status Green LED = Ad-Hoc Status Yellow LED = Infrastructure Status Green LED = Device Status Red LED = Relay Status Shown With Cover Code Version 4.7.1.1.0 Made in USA Meets "Buy American" of ARRA 2009 Wi-Fi RIBTM # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Operate Time: 18ms Pink LED: Digital Input Status Green LED: Wifi Ad-Hoc Status Yellow LED: Wifi Infrastructure Status Green LED: Device Status Red LED: Relay Status Dimensions: 4.28 x 7.00 x 2.00 with .75 NPT Nipple Approvals: UL Listed, UL916, C-UL FCC, CE, RoHS, Wifi Certified ASD Device Housing Rating: UL Accepted for Use in Plenum, NEMA 4X Gold Flash: No Relay Override Switch: DIP Switch Control Wifi: IEEE 802.11 b/g/n Compatible, (G) 54 Mbps Data Rate 95 dBm Sensitivity +16 dBm Output Power (WPA-PSK or WPA-2-PSK Available) Supports PING and ARP DSSS Modulation Security: Customer can choose to have Webpage and Controller Commands authentication-secured with Username and Password. Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 1 HP @ 120 Vac 2 HP @ 277 Vac Power Input Ratings: 158 mA Max @ 24 Vac 110 mA Max @ 24 Vdc 55 mA Max @ 120 Vac Available TCP/IP Settings: · IP Address (Static) · Port Number · Subnet Mask · Gateway Address · Ad-Hoc mode (Default) · Infrastructure mode · Scan for wireless networks Device Settings: · Local Override · Reset to Network Defaults Pushbutton Power Input (Use one): 24 Vac = Terminal Strip (20 Vac min. ; 28 Vac max.) 24 Vdc = Terminal Strip (24 Vdc min. ; 28 Vdc max.) 120 Vac = Terminal Strip Device Settings by Network: · Power up default relay state · Host name and location labels · Relay bound to digital input · Username and Password security: Note: There will be no security if password field is left blank. A password may be entered that will secure the webpage as well as Controller Commands. Eight alpha-numerical characters case-sensitive. · Setup instructions available on website. http://www.functionaldevices.com/pdf/ bulletins/B1783_393223.pdf Or scan QR code with your smart phone. CAUTION: Remove all connections to UI 1 and UI 2 when setting input. Universal Input: Configurable by internal device web page, accessible in either Ad-Hoc or Infrastructure. · Analog value returned, user configurable min. and max. scale, and label, 0-5 Vdc, 0-10 Vdc, or 4-20 mA*, connect between UI and Com. · Direct temperature reading from Type T2 Thermistor. Connect between +5 Vdc and UI input. · Digital Input, connect between +5 Vdc and UI input. * 4-20 mA, when used, requires jumper to be installed on UI set for 4-20 mA input. Jumper MUST be removed when UI input used as anything other than 4-20 mA. For application manual, please visit: www.functionaldevices.com (800) 888-5538 | www.functionaldevices.com 81 RELAYS NETWORK COMPATIBLE RELAYS RIBMNW24B-MBAI 2.75" Track Mount Modbus® RTU Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (Dry Contact, Class 2); One Analog Input (T2 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included. RIBTW24B-MBAI Enclosed Modbus® RTU Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (Dry Contact, Class 2); One Analog Input (T2 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included. Made in USA Meets "Buy American" of ARRA 2009 Green LED=Network Status Red LED=Relay Status Pink LED=BI 1 Status Pink LED=BI 2 Status BI 1 COM BI 1 BI 2 COM BI 2 5 V 10 V 1 2 A() B(+) REF OPEN ^ To select AI for Thermistor Standard RS-485 Modbus® RTU Protocol. AI Voltage Select Switch T2 input, install jumper. EOL termination resistor jumper. 1 0 Connect jumper for terminating resistor. Relay Control 1 2 3 4 5 6 7 8 9 10 11 12 Baud Rate LSB Modbus® RTU ADDRESS MSB Both jumpers installed from factory. Remove left jumper from Thermistor-Input-Select^ for T2 Thermistor Input, otherwise leave both on for 5V or 10V Analog In. Connect Analog In between AI and AI common. Connect Thermistor between AI and Thermistor +5V. O O Not de ned O On T2 Thermistor On On Analog In 5V or 10V Type Analog AI AI COM Therm. +5V Analog In (Close only one) SW1 Closed 5 V SW2 Open 10 V SW1 Open SW2 Closed Thermistor T2 input, use 5 V selection Contacts Relay N/C } COM 24 Vac/dc Common N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.25 x 2.75 x 1.75 (RIBMNW24B-MBAI) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTW24B-MBAI) Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac Network Media: Twisted Pair 22-24AWG, shielded recommended, EIA/TIA-485 (standard RS485) Terminations: Functional Devices product installed at both ends of the standard RS485 Modbus® RTU network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the Modbus® network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600 (DIP Switch Selectable) Notes: · Modbus®Address & Baud Rate must be set prior to power up via DIP switches. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24B-MBAI-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTW24B-MBAI-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTW24B-MBAI-N4-GY) · This model utilizes: Physical coil 1 (Relay output) Physical binary input 1 (Dry contact binary input) Physical binary input 2 (Dry contact binary input) Physical input register AI 1 (Analog input) · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor not included. (Range -39 to 187°F) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below.^^ · Address and Baud Rate Settings on Bulletin B1676 available on website. http://functionaldevices.com/pdf/bulletins/B1676_393208.pdf Or scan QR code with your smart phone. DIP SWITCHES* BAUD RATE DIP SWITCHES* RELAY STATE** 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 All other combinations=9600 baud 9600 19200 38400 57600 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to feed back to the network. Modbus® is a registered trademark of Schneider Electric licensed to the Modbus Organization, Inc. 24 Vac RIBMNW24B-MBAI or RIBTW24B-MBAI 24 Vac/dc Com Half-Wave Device 24 Vac Com ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). IN4004 82 Functional Devices, Inc. | American Made. American Owned. RELAYS SPECIALTY PERIPHERAL CONTROLS Fan Safety Alarm Circuits I/O Expanders Manual Analog Override Switch Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). If we do not already build a device with specifications or packaging configurations you require, we will be happy to quote and design one for you. Functional Devices, Inc. is actively involved in the development, manufacturing, and production of special peripheral devices. They are either variations of existing Functional Devices products or entirely unique devices. We will help provide you with a product to fit your specific needs. Please contact us so we may review your project and special requirements. FAN SAFETY ALARM CIRCUITS MODEL # RIBMNLB · RIBLB · RIBMNLB-6 · RIBMNLB-4 · RIBMNLB-2 · RIBMNLB-1 · RIBLB-6 · RIBLB-4 · RIBLB-2 · RIBMNLB-6NO · RIBMNLB-4NO · RIBMNLB-2NO · POWER INPUT 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac ALARM CIRCUITS 4 4 6 4 2 2 6 4 2 6 4 2 CONTACTS SWITCH ENCLOSED · · · · NOTES NEW NEW NEW NEW SPEC PAGE 84 84 85 85 85 87 85 85 85 86 86 86 I/O EXPANDERS MODEL # RIBMN24Q2C 1 POWER INPUT · 24 Vac/dc RIBMN24Q3C · 24 Vac/dc RIBMN24Q4C · 24 Vac/dc RIBMN24Q4C-PX · 24 Vac/dc RELAYS 2 3 4 4 CONTACTS 2 SPDT 3 SPDT 4 SPDT 4 SPDT SWITCH (Quick reference only. See individual spec page for more information.) ENCLOSED NOTES SPEC PAGE 88 88 89 89 MANUAL ANALOG OVERRIDE SWITCH MODEL # RIBMNA1D0 POWER INPUT 24 Vac/dc RELAYS SWITCH Manual / Auto = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 1= UL Listed : UL916 Energy Management ; USA & Canada ENCLOSED · NOTES SPEC PAGE 90 (800) 888-5538 | www.functionaldevices.com 83 RELAYS FAN SAFETY ALARM CIRCUITS RIBMNLB 2.75 Track Mount AHU Fan Safety Alarm Circuit, 24 Vac Power Input RIBLB Enclosed AHU Fan Safety Alarm Circuit, 24 Vac Power Input Power Input 4A Max. Dry Contact Inputs (From Field) Powered Contact Outputs 2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 3A @ 24Vac /dc 750mA @ 24Vac/dc 1 2 24 Vac/dc Power On 3 4 Low Limit 1 5 Static Pressure Limit 1 6 Smoke Detector/FA Low Limit On Static Smoke Pressure Detector/FA On On Latched Input Selector DIP Switch Latch Reset Low Limit Relay Static Pressure Relay Low Limit Static Pressure Digital In Digital In 10 11 12 13 1 7 Fan Status Fan Status On 1 8 24V COM Actuator Power 1 9 24V COM Fan Safety Smoke Detector/ FA Relay Fan Status Relay Master Relay Master Relay On Smoke Detector/ Fan Status FA Digital In Digital In 14 15 16 17 For Indoor Use in Dry Locations 8A @ 24Vac/dc J1 Jumper 8A @ 24Vac/dc 8A @ 24Vac/dc 8A @ 24Vac/dc Dry Contact Outputs (To Controller) Dry Contact Output 10A @ 277 Vac 10A @ 30 Vdc 1/2 HP@120/240Vac B300 Pilot Duty CAN BE USED TO ISOLATE FIELD DEVICES FROM EACH OTHER AND FROM CONTROLLER, NOT ONLY FAN CIRCUITS SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 250ms Power Input: 4 Amp @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 6.000 x 2.750 x 1.200 (RIBMNLB) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBLB) Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL864, C-UL, CE, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved Gold Flash: No Override Switch: No Notes: · RIBMNLB and RIBLB have four Alarm Inputs and one Master Alarm. Panel Black Black RC-1 5Amp White White Green TX-1 1 x 1 24Vac 1 x 2 DC-1 Power 24Vac COM DC-1 DO-3 A master relay will open if any one of the normally-closed (N/C) inputs open. LED status of all outputs and the master relay is provided. The RIBMNLB is provided with mounting track for mounting in user-provided electrical enclosures. The RIBLB is enclosed in a NEMA 1, 4 x 7 enclosure with a clear lid to allow viewing of the status LEDs. The master relay has two general-purpose outputs: one 24 V output terminal and one dry contact output rated up to 10 Amp @ 277 Vac. Fan status contact controls actuator power. The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown. Model RIBMNLB combines all the relay logic to facilitate fan status, fan safety control, and damper actuator control. It is intended for use in a circuit that will control fan start/stop and fan safety shut-down circuit monitors three critical inputs: · Low-limit freeze protection (to stop fan and remove power from damper actuator) · Static pressure (to monitor for hi/low pressure condition) · Smoke detector / fire alarm Master relay opens to shut down AHU when any Normally Closed input opens. Integral DIP switch allows any input to be latched. Input can be reset with push button or by cycling unit power. Installing J1 jumper allows Fan Status input to control Master Relay, like the other 3 inputs. Digital inputs to controller 1 R4 FS-S 24Vac 16 Fan Status DI 17 R1 LL-A 10 Low Limit DI 11 R2 SP-A 12 Static Press Alarm DI 13 R3 Smoke/Fire Alarm 14 Smoke / Fire Alarm DI 15 DL-1 2 24Vac R1 LL-A R2 SP-A R3 SMK/FA 1 9 PB-1 R1 LL-A R1 LL-A 3 4 1 5 R2 SP-A 1 6 R3 SMK/FA 1 R4 FS-S 7 RIBMNLB (Track Mount) RIBLB (Enclosed) At power-up, delay 2 sec before DL-1 becomes activated R4 FS-S 1 8 DL-1 Made in USA Meets "Buy American" of ARRA 2009 CODE VER. 1.0 Field H 120Vac N Emergency Power G with ground X1 120Vac X2 Starter H O A Contactor Ols RIBTU2C Wht/Blu Blu Yel Wht/Yel Org Gry/Wht Gry Prp Wht/Prp Brn Fan Safety Relay Low Limit Static Pressure Smoke Detector / Fire Alarm Tn To Motor Status FS-S RIBX Series Fan Status Actuator Power This drawing represents: · Only Low Limit Latch Set · J1 Jumper Not Installed 84 Functional Devices, Inc. | American Made. American Owned. FAN SAFETY ALARM CIRCUITS RIBMNLB-6/-4/-2 2.75 Track Mount AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input, 2/4/6 Outputs Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc RIBLB-6/-4/-2 Enclosed AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input, 2/4/6 Outputs 3A Total Sourced from 24 Vac/dc Input R1 OUT N/C R2 OUT N/C R1 R2 Alarm Input Indicators CLOSED 12 R3 OUT N/C R4 OUT N/C R3 R4 CLOSED 34 R5 OUT N/C R5 R6 OUT N/C R6 COM 24V COM 24V R7 POLE 1 R7 POLE 2 10A @ 277 Vac 10A @ 24 Vdc 1/2 HP @ 120/240 Vac B300 Pilot Duty Max. Isolated Dry Contact Output Master Relay R7 Master Alarm Indicator CLOSED 56 24V Power R1 R1 COM OPEN R2 R2 COM R3 R3 COM OPEN R4 R4 COM R5 R5 COM OPEN R6 R6 COM COM 24V Alarm Input 1 Alarm Input 2 Alarm Input 3 Alarm Input 4 Alarm Input Bypass Switches Alarm Input 5 Alarm Input 6 SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Power Input: 4 Amp max. @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 6.200 x 2.750 x 1.750 (RIBMNLB-6) 4.600 x 2.750 x 1.750 (RIBMNLB-4) 3.000 x 2.750 x 1.750 (RIBMNLB-2) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBLB-6/-4/-2) Track Mount: MT212-6 Mounting Track Provided (RIBMNLB-6) MT212-4 Mounting Track Provided (RIBMNLB-4, RIBMNLB-2) Approvals: UL Listed, UL916, UL864, C-UL, CE, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum Gold Flash: No Override Switch: No Notes: · Track mount models shown above. · RIBMNLB-6 and RIBLB-6 have six Alarm Inputs and one Master Alarm. RIBMNLB-4 and RIBLB-4 have four Alarm Inputs and one Master Alarm. RIBMNLB-2 and RIBLB-2 have two Alarm Inputs and one Master Alarm. Models RIBMNLB-6, RIBMNLB-4, and RIBMNLB-2; and RIBLB-6, RIBLB-4, and RIBLB-2 are simply devices that combine a common relay-logic function into a small, easy-to-install, and less expensive form. A master relay will open if any one of the normally-closed (N/C) inputs open. There are six, four, or two inputs depending on the model chosen. LED status of all inputs, the master relay, and power input is provided. Bypass of un-used inputs is also provided. The RIBMNLB series is provided with mounting track for mounting in user-provided electrical enclosures. The RIBLB series is enclosed in a NEMA-1, 4 x 7 enclosure with a clear lid to allow viewing of the status LEDs. The master relay has three general-purpose outputs: two 24 V output terminals and one dry-contact output rated up to 10 Amp @ 277 Vac (terminals on RIBMNLB series, wires on RIBLB series.) The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown. SELECTION GUIDE Model# Inputs RIBMNLB-6 6 MT212 Mounting Track RIBMNLB-4 4 MT212 Mounting Track RIBMNLB-2 2 MT212 Mounting Track RIBLB-6 6 PE6020 Enclosure RIBLB-4 4 PE6020 Enclosure RIBLB-2 2 PE6020 Enclosure 4A Max 10A @ 277 Vac (Typically used to shut down fan) 24 Vac (Typically used to shut down other relays) Low Temp Alarm to DDC Controller High Temp Alarm to DDC Controller Low Press Alarm to DDC Controller High Press Alarm to DDC Controller Smoke Alarm #1 to DDC Controller Smoke Alarm #2 to DDC Controller R7-2 R1-1 R2-1 R3-1 R4-1 R5-1 R6-1 R7 R7-1 Close bypass switch if input not in use. R1-2 Input 1 Bypass R1 R1-3 Input 1 Alarm Indicator R2-2 Input 2 Bypass R2 R2-3 Input 2 Alarm Indicator R3-2 Input 3 Bypass R3 R3-3 Input 3 Alarm Indicator R4-2 Input 4 Bypass R4 R4-3 Input 4 Alarm Indicator R5-2 Input 5 Bypass R5 R5-3 Input 5 Alarm Indicator R6-2 Input 6 Bypass R6 R6-3 Input 6 Alarm Indicator RIBMNLB-6 (Track Mount) RIBLB-6 (Enclosed) (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 24 Vac Power Input Typical alarm inputs shown below. Any alarm inputs may be used and in any order. (Alarm inputs must be N/C.) Input 1 Low Temp Alarm Input 2 High Temp Alarm Input 3 Low Press Alarm Input 4 High Press Alarm Input 5 Smoke Alarm #1 Input 6 Smoke Alarm #2 85 RELAYS RELAYS To DDC Controller FAN SAFETY ALARM CIRCUITS RIBMNLB-6NO/-4NO/-2NO 2.75" Track Mount AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac Power Input, 2/4/6 Alarm Inputs all with N/O Outputs Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc 3A Total Sourced from 24 Vac/dc Input or Dry Contact (Jumper Selectable) R1 OUT N/O R2 OUT N/O R3 OUT N/O R4 OUT N/O R5 OUT N/O R6 OUT N/O R7 R7 POLE 1 POLE 2 Legend for Jumper Selection Dry = R1 R2 Alarm Input Indicators CLOSED 12 R3 R4 CLOSED 34 R5 R6 Master Relay R7 CLOSED 56 R1 R1 COM OPEN R2 R2 COM R3 R3 COM OPEN R4 R4 COM R5 R5 COM OPEN R6 R6 COM COM 24V Master Alarm Indicator 24V = 24V Power Alarm Input 1 Alarm Input 2 Alarm Input 3 Alarm Input 4 Alarm Input Bypass Switches Alarm Input 5 Alarm Input 6 SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Power Input: 4 Amp max. @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 6.200 x 2.750 x 1.750 (RIBMNLB-6NO) 4.600 x 2.750 x 1.750 (RIBMNLB-4NO) 3.000 x 2.750 x 1.750 (RIBMNLB-2NO) Track Mount: MT212-6 Mounting Track Provided (RIBMNLB-6NO) MT212-4 Mounting Track Provided (RIBMNLB-4NO, RIBMNLB-2NO) Approvals: UL Listed, UL916, UL864, C-UL, CE, RoHS Gold Flash: No Override Switch: No Models RIBMNLB-6NO, RIBMNLB-4NO, and RIBMNLB-2NO are simply devices that combine a common relay-logic function into a small, easy-to-install, and less expensive form. A master relay will open if any one of the normally-closed (N/C) inputs open. There are six, four, or two inputs depending on the model chosen. LED status of all inputs, the master relay, and power input is provided. Bypass of un-used inputs is also provided. The RIBMNLB series is provided with mounting track for mounting in user-provided electrical enclosures. The master relay has two general-purpose outputs: both can be jumper selected at 24 V (sourced from input) or dry contact. The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown. Notes: · RIBMNLB-6NO has six Alarm Inputs and one Master Alarm. · RIBMNLB-4NO has four Alarm Inputs and one Master Alarm. · RIBMNLB-2NO has two Alarm Inputs and one Master Alarm. · This is a half wave device. When connecting 24 Vac to both this device and a full-wave device, damage to device can occur. SELECTION GUIDE Model# Inputs RIBMNLB-6NO 6 RIBMNLB-4NO 4 RIBMNLB-2NO 2 MT212 Mounting Track MT212 Mounting Track MT212 Mounting Track 4A Max Input 1 24 Vac Input Power Com 24 V R1-3 Input 2 R2-3 Input 3 R3-3 Input 4 R4-3 Input 5 R5-3 Input 6 R6-3 R1-1 R2-1 R3-1 Input 1 Bypass Input 2 Bypass Input 3 Bypass R7-3 R7-1 Output Con guration Jumper Dry Contact Wet Contact P1 P2 P3 P4 R4-1 Input 4 Bypass 24 Vac Preset Indicator R1 R1 Alarm Indicator R2 R2 Alarm Indicator R3 R3 Alarm Indicator R4 R4 Alarm Indicator R5-1 Input 5 Bypass R5 R5 Alarm Indicator R6 R6 Alarm Indicator R6-1 R7 Input 6 Bypass R7 Alarm Indicator R7-2 Output Con guration Jumper R7-1 Dry Contact Wet Contact P5 P6 P7 P8 R7-2 RIBMNLB-6NO Made in USA Meets "Buy American" of ARRA 2009 R1-2 R2-2 R3-2 R4-2 R5-2 R6-2 86 Functional Devices, Inc. | American Made. American Owned. RELAYS FAN SAFETY ALARM CIRCUIT RIBMNLB-1 2.75" Track Mount General Purpose Latching Logic Circuit; One Latching/Fault Input (Dry Contact, Class 2); 24 Vac/dc Power Input Made in USA Meets "Buy American" of ARRA 2009 24 Vac/dc Comm Power Input RESET Pushbutton Power Latch/Fault Status Status Latch/Fault Input · MANUAL RESET · ONE ALARM OUTPUT · ONE RELAY OUTPUT N/C Com N/O N/O Com N/C SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Green LED: Power Status (ON: Power present) Red LED: Fault Status (ON: Latched/Fault State) Dimensions: 4.00 x 2.75 x 1.25 Track Mount: MT212-4 Mounting Track Provided Approvals: CE, UL Listed, UL864, C-UL, RoHS Gold Flash: No Relay Override Switch: No Fault Reset Switch: Yes Contact Ratings: 10 Amp Resistive @ 30Vdc 10 Amp General Use @ 277Vac 1/2 HP @ 120/240Vac (N/O) 1/3 HP @ 120/240Vac (N/C) Power Input Ratings: 53 mA @ 24Vac 25 mA @ 24Vdc 50/60 Hz H 24 Vac N Safety Latch Circuit Application Alarm Fault Application: When the Latch/Fault Input is Closed (Normal state), the Relay is activated, and Red LED is Off. When Latch/Fault Input Opens (Alarm state), the Relay deactivates, and Red LED turns On. Until the Latch/ Fault Input is Closed AND either power is cycled or the RESET button is pressed, relay will remain in the Alarm state. Notes: · Fault conditions must last for at least 500 ms in order for the unit to go into Alarm state. · Reset signal, whether via pushbutton or power cycling, must last for at least 30 ms in order to reset the device to go from Alarm state to Normal state. LATCH RESET PB1 NC BI R LT-A BLK Auto-reset 24 VAC/DC H N L Power Indicator Fault Input Latch Circuit RIBMNLB-1 Circuit must latch on power up. Circuit must not relatch before or after fault has been cleared. Circuit must only relatch when power is reset. L Alarm Indicator LR1 LR1-1 LR1-2 LR1-3 LR1-4 Output HP-A BI R 12 BLK P Man-reset LP-A BI R 12 BLK P Man-reset BI HT-A R 12 BLK Man-reset 24 VAC H N L Power Indicator R5-2 R5-3 L R1-1 R2-1 R3-1 R4-1 R5 R4-1 Fault Input 1 Input 1 Bypass Fault Input 2 Input 2 Bypass Fault Input 3 Input 3 Bypass Fault Input 4 Input 4 Bypass RIBMNLB-4 (ordered separately) R1 R1-3 L R1-2 R2 R2-3 L R2-2 R3 R3-3 L R3-2 R4 R4-3 L R4-2 Master Power Indicator Typically Used for Fan Shutdown 2046 BI BC LOCATED IN R EAD-ES BLK Alarm Indicator LT-A Status Alarm Indicator HP-A Status Alarm Indicator LP-A Status Alarm Indicator HT-A Status Typical Field Interlock Wiring 2046 DA 4054 AD 4054 AD LOCATED IN SUPPLY FAN MCC PANEL FAN #1. BO A1 SDR-1 A2 R BLK N.O. C 4054 CB LOCATED IN SUPPLY FAN MCC PANEL FAN #2. BO A1 SDR-1a A2 R BLK N.O. C 4054 CB LOCATED IN RETURN / EXHAUST FAN MCC PANEL FAN #1. 4055 AD BO A1 SDR-2 A2 R BLK 4055 CB N.O. C LOCATED IN RETURN / EXHAUST FAN MCC PANEL FAN #2. 4055 AD BO A1 SDR-2a A2 R BLK 4055 CB N.O. C (800) 888-5538 | www.functionaldevices.com 87 RELAYS I/O EXPANDER RIBMN24Q2C 2.75 Track Mount 2 Output I/O Expander with 24 Vac/dc Power Input and 0-10 Vdc / 0-5 Vdc Control Input AI Comm 0-10 Vdc / 0-5 Vdc 24 Vac/dc Comm * Relay 1 Relay 2 0-10 VDC CONTROL VOLTAGE 0-2.117Vdc 0-5 VDC * CONTROL VOLTAGE 0-1.058Vdc RELAY 1 STATUS OFF RELAY 2 STATUS OFF 2.745-4.627Vdc 1.373-2.313Vdc ON OFF 5.255-7.137Vdc 2.628-3.568Vdc OFF ON 7.765-10.000Vdc 3.883-5.000Vdc ON ON N/C COM N/O N/C COM N/O SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 3.100 x 2.750 x 1.750 Track Mount: MT212-4 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Made in USA Meets "Buy American" of ARRA 2009 GREAT FOR STAGING LOADS SUCH AS CHILLERS, PUMPS, ACTUATORS, OR MULTI-STAGE HEATING Power Input: 24 Vac/dc ; 50-60 Hz 100mA max. Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders. I/O EXPANDER RIBMN24Q3C 2.75 Track Mount 3 Output I/O Expander with 24 Vac/dc Power Input and 0-10 Vdc / 0-5 Vdc Control Input AI Comm 0-10 Vdc / 0-5 Vdc 24 Vac/dc Comm 0-10 VDC 0-5 VDC * RELAY RELAY RELAY CONTROL CONTROL 1 2 3 VOLTAGE VOLTAGE STATUS STATUS STATUS 0-0.988Vdc 0-0.494Vdc OFF OFF OFF * 1.366-2.242Vdc 0.683-1.121Vdc ON OFF OFF Made in USA Meets "Buy American" of ARRA 2009 2.620-3.496Vdc 1.310-1.748Vdc OFF ON OFF Relay 1 Relay 2 Relay 3 3.876-4.752Vdc 1.938-2.376Vdc ON ON OFF 5.130-6.006Vdc 2.565-3.003Vdc OFF OFF ON 6.386-7.262Vdc 3.193-3.631Vdc ON OFF ON N/C COM N/O N/C COM N/O N/C COM N/O SPECIFICATIONS 7.640-8.516Vdc 3.820-4.258Vdc OFF ON ON 8.896-10.000Vdc 4.448-5.000Vdc ON ON ON GREAT FOR STAGING LOADS SUCH AS CHILLERS, PUMPS, ACTUATORS, OR MULTI-STAGE HEATING # Relays & Contact Type: Three (3) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 4.000 x 2.750 x 1.750 Track Mount: MT212-4 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 150mA max. Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders. 88 Functional Devices, Inc. | American Made. American Owned. RELAYS I/O EXPANDER RIBMN24Q4C 2.75 Track Mount 4 Output I/O Expander with 24 Vac/dc Power Input and 0-10 Vdc / 0-5 Vdc Control Input 0-10 VDC CONTROL VOLTAGE 0-0.372Vdc 0-5 VDC * CONTROL VOLTAGE 0-0.186Vdc RELAY RELAY RELAY RELAY 1 2 3 4 STATUS STATUS STATUS STATUS OFF OFF OFF OFF 0.726-1.000Vdc 0.363-0.500Vdc ON OFF OFF OFF Made in USA Meets "Buy American" of ARRA 2009 AI Comm 0-10 Vdc / 0-5 Vdc 24 Vac/dc Comm 1.354-1.626Vdc 0.677-0.813Vdc OFF ON OFF OFF 1.982-2.254Vdc 0.991-1.127Vdc ON ON OFF OFF * 2.608-2.882Vdc 1.304-1.441Vdc OFF OFF ON OFF 3.236-3.508Vdc 1.618-1.754Vdc ON OFF ON OFF 3.864-4.136Vdc 1.932-2.068Vdc OFF ON ON OFF Relay 1 Relay 2 Relay 3 Relay 4 4.492-4.764Vdc 2.246-2.382Vdc ON ON ON OFF 5.118-5.392Vdc 2.559-2.696Vdc OFF OFF OFF ON N/C COM N/O N/C COM N/O N/C COM N/O N/C COM N/O 5.746-6.018Vdc 2.873-3.009Vdc ON OFF OFF ON 6.374-6.646Vdc 3.187-3.323Vdc OFF ON OFF ON 7.000-7.274Vdc 3.500-3.637Vdc ON ON OFF ON 7.628-7.902Vdc 3.814-3.951Vdc OFF OFF ON ON GREAT FOR STAGING LOADS SUCH AS CHILLERS, PUMPS, ACTUATORS, OR MULTI-STAGE HEATING 8.256-8.528Vdc 4.128-4.264Vdc ON OFF ON ON 8.884-9.156Vdc 4.442-4.578Vdc OFF ON ON ON SPECIFICATIONS 9.510-10.000Vdc 4.755-5.000Vdc ON ON ON ON # Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 4.950 x 2.750 x 1.750 Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 200mA max. Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders. I/O EXPANDER RIBMN24Q4C-PX 2.75 Track Mount 4 Output Field Adjustable Staging Threshold Relay Module with 24 Vac/dc Power and 0-10 Vdc Control Input AI Comm () 0-10 Vdc 24 Vac/dc Comm (+) Analog }Input Power }Input Setup Display DN UP Relay 1 Relay 2 Relay 3 Relay 4 · CONTROL FOUR RELAY OUTPUTS WITH ONE (0-10 VDC) ANALOG SIGNAL FROM CONTROLLER OR THERMOSTAT · CAPABILITY TO SET DESIRED ON AND OFF VOLTAGES FOR EACH RELAY · NO POTS TO ADJUST · NO NEED FOR VOLT METER FOR SETUP · ON BOARD "FIELD SELECTABLE" DIGITAL DISPLAY Made in USA Meets "Buy American" of ARRA 2009 N/C COM N/O N/C COM N/O N/C COM N/O N/C COM N/O SPECIFICATIONS # Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Heartbeat Status: Right-most decimal point Dimensions: 4.950 x 2.750 x 1.750 Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 200mA max. Notes: · For AC applications, an isolation transformer, to be used solely for the power input, is recommended. · Relay will activate when control signal voltage reaches or exceeds individual relay ON point. Relay will deactivate when control voltage reaches or drops below individual OFF point. · Factory relay ON / OFF voltages: · Relay 1: 3V / 2.8V · Relay 2: 5V / 4.8V · Relay 3: 7V / 6.8V · Relay 4: 9V / 8.8 V · Minimum ON point: 0.5V · Maximum ON point: 9.9V · Minimum OFF point: 0.3V · Relay number will flash 3 times when voltage exceeds setpoint. · Pressing UP or DN button in normal run mode will display the voltage present on Analog Input. · ON/OFF points can be changed at any time, by the user, by entering "Program Mode" · User defined ON/OFF points will be maintained upon power loss. (800) 888-5538 | www.functionaldevices.com 89 RELAYS Output + Output MANUAL ANALOG OVERRIDE SWITCH RIBMNA1D0 2.75 Track Mount Manual Analog Override Switch + Monitor with 24 Vac/dc Power Input Signal + Signal Power Power + Manual Auto 80% 60% 40% 20% + Potentiometer Feedback Legend for Selecting Output for Jumpers Top 2 pins covered by jumper Bottom 2 pins covered by jumper Only 1 pin covered by jumper 5 Vdc 10 Vdc 15 Vdc 20 mA Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 2.450 x 2.750 x 1.270 Track Mount: 2.750", See MT212 Series on page 142 MT212 Mounting Track Sold Separately Input Voltage: 24 Vac/dc Input Current: 90mA Max. Range/Impedance Override: 0-5 Vdc, 200 Min. 0-10 Vdc, 400 Min. 0-15 Vdc, 1 k Min. 0-20mA dc, 500 Max. Feedback Contact: 2A Max. @ 24 Vac/dc Notes: · Set the jumpers according to your input signal (Analog signal from the controller.) Example: When controlling a damper with 0-10 Vdc, the jumpers need to be in position for the 0-10 Vdc override range. If the LED range does not match your analog scale, ensure the jumpers are set for the proper range. · Feedback contact closed when switch is in Manual position, open when switch is in Auto position. · PROVIDES MANUAL OVERRIDE IF CONTROLLER DOES NOT SUPPORT OVERRIDE CAPABILITY · ALLOWS YOU TO MANUALLY MAKE ADJUSTMENTS TO YOUR END DEVICE REMOTELY INSTEAD OF AT YOUR CONTROL PANEL · SENDS OVERRIDE STATUS BACK TO CONTROLLER VIA FEEDBACK · MULTI-RANGE ANALOG OUTPUT 90 Functional Devices, Inc. | American Made. American Owned. CURRENT SENSORS CURRENT SENSORS Solid and Split Core | Enclosed | Track Mount Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Many Variations · Miniature size · Voltage outputs · 4-20 mA regulation · Adjustable or fixed · Self-calibrating · Relay and current sensor combinations · Track mount styles SOLID AND SPLIT CORE AC SENSORS MODEL # RIBXKF RIBXKTF RIBXKA RIBXKTA RIBXGHF RIBXGHTF RIBXGHA RIBXGHTA RIBXGF RIBXGFL RIBXGTF RIBXGTFL RIBXGA RIBXGTA RIBXGA-SCAL RIBXGTA-SCAL RIBXG21F RIBXG21TF RIBXG21A RIBXG21TA RIBXKTV5-10 RIBXKTV5-20 RIBXKTV5-50 RIBXKTV5-100 RIBXK420-20 RIBXK420-50 RIBXK420-100 RIBXGTV10 RIBXG420-20 RIBXG420-50 RIBXG420-100 SENSOR OUTPUT RANGE TYPE · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max (Wire Leads) .25-150A Solid · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max (Terminals) .25-150A Solid · Solid State Switch SPST ; 30 Vac/dc ; .8 Amps Max (Wire Leads) .50-150A Solid · Solid State Switch SPST ; 30 Vac/dc ; .8 Amps Max (Terminals) .50-150A Solid · Solid State Switch SPST ; 120Vac, 1 Amp Max (Wht/Blk 16 18 AWG Wire Leads) .50-150A Split · Solid State Switch SPST ; 120Vac, 1 Amp Max (Terminal Strip, Accepts #14-22 AWG Wire) .50-150A Split · Solid State Switch SPST ; 120Vac, 1 Amp Max (Wht/Blk 16 18 AWG Wire Leads) .75-150A Split · Solid State Switch SPST ; 120Vac, 1 Amp Max (Terminal Strip, Accepts #14-22 AWG Wire) .75-150A Split · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max (Wire Leads) .35-150A Split · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max (Wire Leads) .75-150A Split · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max (Terminals) .35-150A Split · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max (Terminals) .75-150A Split · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max (Wire Leads) .75-150A Split · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max (Terminals) .75-150A Split · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max (Wire Leads) 3-150A Split · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max (Terminals) 3-150A Split · Solid State Switch SPST ; 120-277Vac, 1 Amp Max (Wht/Blk 16 18 AWG Wire Leads) .50-150A Split · Solid State Switch SPST ; 120-277Vac, 1 Amp Max (Terminal Strip, Accepts #14-22 AWG Wire) .50-150A Split · Solid State Switch SPST ; 120-277Vac, 1 Amp Max (Wht/Blk 16 18 AWG Wire Leads) .75-150A Split · Solid State Switch SPST ; 120-277Vac, 1 Amp Max (Terminal Strip, Accepts #14-22 AWG Wire) .75-150A Split · 0-5 Vdc Voltage Output (Terminals) 0-10A Solid · 0-5 Vdc Voltage Output (Terminals) 0-20A Solid · 0-5 Vdc Voltage Output (Terminals) 0-50A Solid · 0-5 Vdc Voltage Output (Terminals) 0-100A Solid · Loop Powered 4-20mA Transmitter Output (Wire Leads) 0-20A Solid · Loop Powered 4-20mA Transmitter Output (Wire Leads) 0-50A Solid · Loop Powered 4-20mA Transmitter Output (Wire Leads) 0-100A Solid · 0-10 Vdc Voltage Output (Terminals) 0-20A, 0-50A, 0-100A Split · Loop Powered 4-20 mA Transmitter (Wire Leads) 0-20A Split · Loop Powered 4-20 mA Transmitter (Wire Leads) 0-50A Split · Loop Powered 4-20 mA Transmitter (Wire Leads) 0-100A Split THRESHOLD Fixed, .25 Amp Fixed, .25 Amp Adjustable Adjustable Fixed, .50 Amp Fixed, .50 Amp Adjustable Adjustable Fixed, .35 Amp Fixed, .75 Amp Fixed, .35 Amp Fixed, .75 Amp Adjustable Adjustable Adjustable Adjustable Fixed, .50 Amp Fixed, .50 Amp Adjustable Adjustable Analog Analog Analog Analog Analog Analog Analog Analog Analog Analog Analog NOTES SPEC PAGE 93 93 93 93 93 93 93 93 94 94 94 94 94 94 94 94 95 95 95 95 95 95 95 95 96 96 96 96 97 97 97 T STYLE AC SENSORS MODEL # RIBXF RIBXA RIBXV RIBXRF RIBXRA RIBXJF RIBXJA SENSOR OUTPUT · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max · Solid State Switch SPST ; 30 Vac/dc-; .4 Amps Max · 0-5 Vdc / 0-10 Vdc Voltage Output · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max RANGE .50-30A .50-30A 0-30A 1.25-150A 1.25-150A 3-150A 3-150A TYPE Internal Internal Internal Solid Solid Split Split THRESHOLD Fixed, .50 Amp Adjustable Analog Fixed, 1.25 Amp Adjustable Fixed, 3 Amp Adjustable NOTES SPEC PAGE 98 98 98 98 98 99 99 TRACK MOUNT AC SENSORS MODEL # RIBMXV RIBMXRF RIBMXRA SENSOR OUTPUT · 0-5 Vdc / 0-10 Vdc Voltage Output · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max · Solid State Switch SPST ; 30 Vac/dc ; .4 Amps Max = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada RANGE 0-20A 3-150A 3-150A TYPE Internal Solid Solid THRESHOLD Analog Fixed, 3 Amp Adjustable NOTES SPEC PAGE 99 99 99 (800) 888-5538 | www.functionaldevices.com 91 CURRENT SENSORS CURRENT SENSOR & RELAY COMBINATIONS Enclosed | Track Mount Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). ENCLOSED AC SENSORS WITH RELAYS MODEL # RIBHX24BF RIBXLCF RIBXLCA RIBXLCV RIBXLCEA RIBXLCEV RIBXLCRF RIBXLCRA RIBXLCJF RIBXLCJA RIBXLSF RIBXLSA RIBXLSV RIBXLSEA RIBXLSEV RIBXLSRF RIBXLSRA RIBXLSJF RIBXLSJA RIBX24BF RIBX24BA RIBX24BV RIBX24SBF RIBX24SBA RIBX24SBV RIBX243PF RIBX243PA RIBX243PV AC/DC · 24 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 10-30 · 24 · 24 · 24 · 24 · 24 · 24 · 1 24 · 1 24 · 1 24 RELAYS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CONTACTS SPST-N/O SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPST SPST SPST SPST SPST SPST SPST SPST SPST SPDT SPDT SPDT SPST SPST SPST 3PST 3PST 3PST OVERRIDE SWITCH 1 1 1 1 1 1 1 1 1 1 1 1 SENSOR RANGE .25-20A .50-10A .50-10A 0 - 10A .125 - 5A 0 - 5A 1.25-150A 1.25-150A 3-150A 3-150A .50-10A .50-10A 0 - 10A .125 - 5A 0 - 5A 1.25-150A 1.25-150A 3-150A 3-150A .50-20A .50-20A 0 - 20A .50-20A .50-20A 0 - 20A .50-20A .50-20A 0 - 20A SENSOR TYPE Internal Internal Internal Internal Internal Internal Solid Solid Split Split Internal Internal Internal Internal Internal Solid Solid Split Split Internal Internal Internal Internal Internal Internal Internal Internal Internal SENSOR THRESHOLD Fixed, .25 Amp Fixed, .50 Amp Adjustable Analog Adjustable Analog Fixed, 1.25 Amp Adjustable Fixed, 3 Amp Adjustable Fixed, .50 Amp Adjustable Analog Adjustable Analog Fixed, 1.25 Amp Adjustable Fixed, 3 Amp Adjustable Fixed, .50 Amp Adjustable Analog Fixed, .50 Amp Adjustable Analog Fixed, .50 Amp Adjustable Analog SPEC PAGE 100 101 101 101 101 101 101 101 101 101 102 102 102 102 102 102 102 102 102 103 103 103 103 103 103 104 104 104 TRACK MOUNT AC SENSORS WITH RELAYS MODEL # RIBMX24BF AC/DC RELAYS CONTACTS OVERRIDE SWITCH SENSOR RANGE SENSOR TYPE SENSOR THRESHOLD · 24 1 SPDT .50-20A Internal Fixed, .50 Amp RIBMX24BA · 24 1 SPDT .50-20A Internal Adjustable RIBMX24BV · 24 1 SPDT 0 - 20A Internal Analog RIBMX24SBF · 24 1 SPST 1 .50-20A Internal Fixed, .50 Amp RIBMX24SBA · 24 1 SPST 1 .50-20A Internal Adjustable RIBMX24SBV · 24 1 SPST 1 0 - 20A Internal Analog SPEC PAGE 105 105 105 105 105 105 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 1 = UL Listed : UL916 Energy Management ; USA & Canada 92 Functional Devices, Inc. | American Made. American Owned. AC CURRENT SWITCHES RIBXK Series Enclosed Self-Powered Solid Core AC Sensors 1.46" CURRENT SENSORS .500" Diameter Wire Clamp Threshold Adjust Sensor Contact 1.863" 2.050" LED 1 LED 2 (if present) Removable Mounting Tab 1.008" 1.508" SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, C-UL, California State Fire Marshal, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Contact Output: Current below threshold: Open ; Current above threshold: Closed RIBXKA Wire Being Monitored Wht/ Yel RIBXKTF Wire Being Monitored Wht/ Yel Made in USA Meets "Buy American" of ARRA 2009 Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp RIBXK SERIES SELECTION GUIDE Model# Sensing Range Type Threshold RIBXKF .25-150 Amp Solid Core Fixed, .25 Amp RIBXKTF .25-150 Amp Solid Core Fixed, .25 Amp RIBXKA .50-150 Amp Solid Core Adjustable RIBXKTA .50-150 Amp Solid Core Adjustable Sensor Contact Type Solid State Switch SPST Solid State Switch SPST Solid State Switch SPST Solid State Switch SPST Switching Voltage Range 30 Vac/dc 30 Vac/dc 30 Vac/dc 30 Vac/dc Maximum Switching Current .4 Amps Max Sensor Contact Termination Wht/Yel 16 18 AWG Wire Leads .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire .8 Amps Max Wht/Yel 16 18 AWG Wire Leads .8 Amps Max Terminal Strip, Accepts #14-22 AWG Wire LED 1 LED 2 Over Trip Point Under Trip Point Over Trip Point Under Trip Point AC CURRENT SWITCHES RIBXGH Series Enclosed Self-Powered Split Core 120 Vac Switching AC Current Sensors Wire Clamp 2.000" Sensor Contact .52" x .52" Opening for Wire Being Monitored 2.520" LED 2 LED 1 Threshold Adjust (if present) 2.000" 1.100" 1.750" RIBXGHF Wire Being Monitored Wht/Blk RIBXGHTF Wire Being Monitored Made in USA Meets "Buy American" of ARRA 2009 Removable Mounting Tab Wht/Blk SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Temperature Derating: 1 Amp up to 50° C, 0.5 Amp up to 60° C Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open Current above threshold: Closed Approvals: UL Listed, UL916, C-UL, CE, RoHS 1 Mounting/ Removable mounting tab provided. The Installation: wire clamp locks against the wire being monitored, securing the unit in place. Notes: · Use Sensor Contact to switch 120 Vac loads only. · For testing purposes, Sensor Contact will measure approximately 250 when closed and > 10 M when open. · The Sensor Contact is a Solid State Contact. RIBXGH SERIES SELECTION GUIDE Model# Sensing Range Type Threshold Sensor Contact Type RIBXGHF .50-150 Amp Split Core Fixed, .50 Amp Solid State Switch SPST Switching Voltage Range 120 Vac Only RIBXGHTF .50-150 Amp Split Core Fixed, .50 Amp Solid State Switch SPST 120 Vac Only RIBXGHA .75-150 Amp Split Core Adjustable Solid State Switch SPST 120 Vac Only RIBXGHTA .75-150 Amp Split Core Adjustable Solid State Switch SPST 120 Vac Only Maximum Switching Current 1 Amp Max Sensor Contact Termination Wht/Blk 16 18 AWG Wire Leads 1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire 1 Amp Max Wht/Blk 16 18 AWG Wire Leads 1 Amp Max Terminal Strip, Accepts #14-22 AWG Wire LED 1 LED 2 Over Trip Point Under Trip Point Over Trip Point Under Trip Point (800) 888-5538 | www.functionaldevices.com 93 AC CURRENT SWITCHES RIBXG Series Enclosed Self-Powered Split Core AC Sensors Wire Clamp 2.000" Sensor Contact .52" x .52" Opening for Wire Being Monitored 2.520" LED 2 LED 1 Threshold Adjust (if present) 2.000" 1.100" 1.750" RIBXGA Wire Being Monitored Wht/Yel Wht/Yel RIBXGTF Wire Being Monitored Made in USA Meets "Buy American" of ARRA 2009 CURRENT SENSORS Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, C-UL, California State Fire Marshal, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Contact Status: Current below threshold: Open Current above threshold: Closed Sensor Contact: · Solid State Contact · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp SELF-CALIBRATING AC SWITCHES (Models with -SCAL Suffix) Sensor Contact -SCAL LED TABLE LED Off No Current Two Winks Current Below Range Three Winks Current In Range Four Winks Current Above Range LED 1 Continuous Winks Calibration in Progress DIP Switch The SCAL unit begins the 30 second self-calibration process the first time current is applied in the operating range. The threshold is then set. Subsequent calibrations may be performed by moving SW1 to the position opposite of its current position with or without current applied (hands can be safely away from live voltage). Once current begins flowing, or if it already is, the calibration process will begin. At the end of the 30 seconds, amperage will be read and set as the threshold. SW2 in the ON position provides a 15% (+/-3%) differential. In the OFF position, it provides a 25% (+/-3%) differential. SW2 can be selected at anytime and does not affect the threshold setting. Current in-range closes the sensor contact. Current above or below range opens the sensor contact. Example: With a current of 10 amps set as the threshold and a 15% differential, sensor contact will be closed between 8.5 amps and 11.5 amps and open outside of this range. A small amount of hysteresis is provided to prevent dithering near the differential limits. RIBXGA-SCAL RIBXGTA-SCAL Made in USA Meets "Buy American" of ARRA 2009 RIBXG SERIES SELECTION GUIDE Model# Sensing Range Type Threshold RIBXGF .35-150 Amp Split Core Fixed, .35 Amp RIBXGFL* .75-150 Amp Split Core Fixed, .75 Amp RIBXGTF .35-150 Amp Split Core Fixed, .35 Amp RIBXGTFL* .75-150 Amp Split Core Fixed, .75 Amp RIBXGA .75-150 Amp Split Core Adjustable RIBXGTA .75-150 Amp Split Core Adjustable RIBXGA-SCAL 3-150 Amp Split Core Self-Cal. RIBXGTA-SCAL 3-150 Amp Split Core Self-Cal. Sensor Contact Type Solid State Switch SPST Solid State Switch SPST Solid State Switch SPST Solid State Switch SPST Solid State Switch SPST Solid State Switch SPST Solid State Switch SPST Solid State Switch SPST Switching Voltage Range 30 Vac/dc 30 Vac/dc 30 Vac/dc 30 Vac/dc 30 Vac/dc 30 Vac/dc 30 Vac/dc 30 Vac/dc Maximum Switching Current .4 Amps Max Sensor Contact Termination Wht/Yel 16 18 AWG Wire Leads .4 Amps Max Wht/Yel 16 18 AWG Wire Leads .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire .4 Amps Max Wht/Yel 16 18 AWG Wire Leads .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire .4 Amps Max Wht/Yel 16 18 AWG Wire Leads .4 Amps Max Terminal Strip, Accepts #14-22 AWG Wire LED 1 LED 2 Over Trip Point Over Trip Point Over Trip Point Under Trip Point Over Trip Point Under Trip Point See -SCAL Table See -SCAL Table * = Not approved by California State Fire Marshal 94 Functional Devices, Inc. | American Made. American Owned. CURRENT SENSORS AC CURRENT SWITCHES RIBXG21 Series Enclosed Self-Powered Split Core 120-277 Vac Switching AC Current Sensors Wire Clamp 2.000" Sensor Contact .52" x .52" Opening for Wire Being Monitored 2.520" Threshold Adjust 2.000" LED 2 LED 1 (if present) 1.100" 1.750" RIBXG21F Wire Being Monitored Wht/Brn RIBXG21TF Wire Being Monitored Made in USA Meets "Buy American" of ARRA 2009 Removable Mounting Tab Wht/Brn SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) * Temperature Derating: 1 Amp up to 50° C, 0.5 Amp up to 60° C Max Sense Voltage: 600 Vac Sensor Contact Status: Monitored current below threshold: Open Monitored current above threshold: Closed Approvals: UL Listed, UL916, C-UL, CE, RoHS Mounting/ Unit can be secured using Installation: the supplied Mounting Tab, the adjustable Wire Clamp, or both. Notes: · Use Sensor Contact to switch 120-277 Vac loads only. · For testing purposes, Sensor Contact will measure approximately 250 when closed and > 10 M when open. · The Sensor Contact is a Solid State Contact. RIBXG21 SERIES SELECTION GUIDE Model# Sensing Range Type Threshold Sensor Contact Type RIBXG21F .50-150 Amps AC Split Core Fixed, .50 Amp AC Solid State Switch SPST RIBXG21TF .50-150 Amps AC Split Core Fixed, .50 Amp AC Solid State Switch SPST RIBXG21A .75-150 Amps AC Split Core Adjustable Solid State Switch SPST RIBXG21TA .75-150 Amps AC Split Core Adjustable Solid State Switch SPST Switching Voltage Range 120-277 Vac 120-277 Vac 120-277 Vac 120-277 Vac Maximum Switching Current 1 Amp AC * 1 Amp AC * 1 Amp AC * 1 Amp AC * Sensor Contact Termination LED 1 LED 2 Wht/Blk 16 18 AWG Wire Leads Terminal Strip, Accepts #14-22 AWG Wire Wht/Blk 16 18 AWG Wire Leads Over Threshold Under Threshold Terminal Strip, Accepts #14-22 AWG Wire Over Threshold Under Threshold AC TRANSDUCERS RIBXKTV Series Enclosed Self-Powered Solid Core Current to DC Transducers 1.460" .500" Diameter 1.863" 2.050" 1.008" + 2.050" Wire Clamp Output: Terminal Strip Accepts 14-22 AWG wire Removable Mounting Tab Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) RIBXKTV SERIES SELECTION GUIDE Accuracy: 96.8% Full Scale Model# Sensing Range Sensor Output Loading: RIBXKTV5-10, 1% Error @ 180 k RIBXKTV5-20, 1% Error @ 90 k RIBXKTV5-10 0-10 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) RIBXKTV5-50, 1% Error @ 40 k RIBXKTV5-20 0-20 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) RIBXKTV5-100, 1% Error @ 15 k Max Sense Voltage: 600 Vac RIBXKTV5-50 0-50 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) Approvals: UL Listed, UL916, UL864, California State Fire Marshal, RIBXKTV5-100 0-100 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Type: Solid core with voltage output (800) 888-5538 | www.functionaldevices.com 95 AC TRANSDUCERS RIBXK420 Series Enclosed Self-Powered Solid Core 20, 50, and 100 Amp Current Transducers with Loop Powered 4-20 mA Output (Pre-Wired) 1.460" CURRENT SENSORS .500" Diameter 1.863" Black () Red (+) 1.008" 2.050" Wire Clamp Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Wires: Red (positive) & Black (negative), 16, 18 AWG, 600V Rated Sensor Type: Internal, with 4-20 mA Transmitter Output Sensor Range: 0-20 Amps, 0-50 Amps, or 0-100 Amps (See Selection Guide Below) Accuracy: 96.4% FS Linearity: 99% FS (25%-100% Span) Max Output Current: 30 mA Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, C-UL, California State Fire Marshal, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. RIBXKTV SERIES SELECTION GUIDE Model# Sensing Range Sensor Output RIBXK420-20 0-20 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) RIBXK420-50 0-50 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) RIBXK420-100 0-100 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) Made in USA Meets "Buy American" of ARRA 2009 Output Load Resistance - + Supply Voltage -+ RIBXK420 Red + Black - OUTPUT LOAD RESISTANCE Maximum 700 ohms 600 ohms 500 ohms 400 ohms 300 ohms 250 ohms 200 ohms 100 ohms 50 ohms SUPPLY VOLTAGE Minimum 26 Vdc 24 Vdc 21 Vdc 19 Vdc 17 Vdc 16 Vdc 14 Vdc 12 Vdc 11 Vdc Maximum 35 Vdc 35 Vdc 35 Vdc 30 Vdc 30 Vdc 28 Vdc 28 Vdc 28 Vdc 28 Vdc AC TRANSDUCER RIBXGTV10 Enclosed Self-Powered Spilt Core Multi-Range (0-20A, 50A, or 100A) AC Transducer with 0-10Vdc Terminal Output Wire Clamp 2.000" .52" x .52" Opening for Wire Being Monitored 2.520" 1.100" 1.750" 2.000" Output: Terminal Strip Accepts 14-22 AWG wire DIP Switches Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Accuracy: 96.8% Full Scale Max Sense Voltage: 600 Vac Approvals: UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Sensor Type: Split core with voltage output 96 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 DIP SWITCH 1 2 OFF OFF OFF ON ON OFF Sensing Range 0-20 Amp 0-50 Amp 0-100 Amp CURRENT SENSORS AC TRANSDUCERS RIBXG420 Series Enclosed Self-Powered Split Core 20, 50, and 100 Amp Current Transducers with Loop Powered 4-20 mA Output (Pre-Wired) Wire Clamp 2.520" 2.000" 1.100" 1.750" .52" x .52" Opening for Wire Being Monitored 2.520" Removable Mounting Tab SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Wires: Red (positive) & Black (negative), 16, 18 AWG, 600V Rated Sensor Type: Internal, with 4-20 mA Transmitter Output Sensor Range: 0-20 Amps, 0-50 Amps, or 0-100 Amps (See Selection Guide Below) Accuracy: Refer to chart below. Linearity: 99% FS (20%-100% Span) Max Output Current: 30 mA Max Sense Voltage: 600 Vac Approvals: UL Listed, UL864, UL508, C-UL, California State Fire Marshal, CE, RoHS Mounting/Installation: Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Made in USA Meets "Buy American" of ARRA 2009 OUTPUT LOAD RESISTANCE Maximum 800 ohms 500 ohms 350 ohms 250 ohms 200 ohms 100 ohms 50 ohms SUPPLY VOLTAGE Minimum 24 Vdc 18 Vdc 15 Vdc 13 Vdc 12 Vdc 10 Vdc 9 Vdc Maximum 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc 35 Vdc RIBXG420 SERIES SELECTION GUIDE Model# Sensing Range Sensor Output RIBXG420-20 0-20 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) RIBXG420-50 0-50 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) RIBXG420-100 0-100 Amps Loop Powered 4-20 mA Transmitter (Pre-Wired) Span 20% 100% 99% 99% 99% ACCURACY Span 10% 100% 99% 97.5% 97% Span 0% 100% 95% 92% 91% · Accuracy charts are available on data sheet on website. http://www.functionaldevices.com/pdf/ datasheets/RIBXG420_SERIES.pdf Or scan QR code with your smart phone. Output Load Resistance - + Supply Voltage -+ RIBXG420 Red + Black - (800) 888-5538 | www.functionaldevices.com 97 CURRENT SENSORS AC CURRENT SWITCHES RIBXF Enclosed Self-Powered Internal Fixed 0.50-30 Amp AC Sensor RIBXA Enclosed Self-Powered Internal Adjustable 0.50-30 Amp AC Sensor Sensor Feedback Current Sensor Status Not Used Current Sensor Circuitry Prp Prp Sensor Feedback Current Sensor Status Not Used Current Sensor Circuitry Prp Prp Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Sensor Type: Internal, with contact status Sensor Threshold: Fixed, .5 Amps (RIBXF) Adjustable, .50-30 Amps (RIBXA) Sensor Range: .50-30 Amps Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open / LED OFF Current above threshold: Closed / LED ON Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp AC TRANSDUCER RIBXV Enclosed Self-Powered Internal 0-30 Amp to 0-5 Vdc / 0-10 Vdc AC Transducer Current Sensor Circuitry Prp Prp V V 0-10 Vdc 0-5 Vdc Comm SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Sensor Type: Internal, with voltage output Sensor Range: 0-30 Amps Max Sense Voltage: 600 Vac Sensor Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 3% full scale · Vripple < 10m Vac Made in USA Meets "Buy American" of ARRA 2009 AC CURRENT SWITCHES RIBXRF Enclosed Self-Powered Solid Ring Remote Fixed 1.25-150 Amp AC Sensor RIBXRA Enclosed Self-Powered Solid Ring Remote Adjustable 1.25-150 Amp AC Sensor Sensor Contact Current Sensor Circuitry AXKT CT Gry Gry Wire Being Monitored Sensor Contact Current Sensor Circuitry AXKT CT Gry Gry Wire Being Monitored SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Remote Dimensions: 1.863 x 1.460, .500 Inside Diameter Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL, California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Sensor Type: External, with contact status Sensor Threshold: Fixed, 1.25 Amps (RIBXRF) Adjustable, 1.25-150 Amps (RIBXRA) Sensor Range: 1.25-150 Amps Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open / LED OFF Current above threshold: Closed / LED ON 98 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp AC CURRENT SWITCHES RIBXJF Enclosed Self-Powered Split Ring Remote Fixed 3-150 Amp AC Sensor Sensor Contact Current Sensor Gry Circuitry Gry Wire Being Monitored AXGT CT RIBXJA Enclosed Self-Powered Split Ring Remote Adjustable 3-150 Amp AC Sensor Sensor Contact Current Sensor Gry Circuitry Gry Wire Being Monitored AXGT CT Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Remote Dimensions: (Outside) 2.52 x 2.00, (Inside) .52 x .52 Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 AC TRANSDUCER RIBMXV 4.00 Track Mount Internal 0-20 Amp to 0-5 Vdc / 0-10 Vdc Self-Powered AC Transducer 0-10 Vdc 0-5 Vdc Comm V V Current Sensor Circuitry Not Used Sensor Type: External, with contact status Sensor Threshold: Fixed, 3 Amps (RIBXJF). Adjustable, 3-150 Amps (RIBXJA) Sensor Range: 3-150 Amps Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open / LED OFF Current above threshold: Closed / LED ON Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Made in USA Meets "Buy American" of ARRA 2009 CURRENT SENSORS SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.700 x 4.000 x 1.250 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Sensor Type: Internal, with voltage output Sensor Range: 0-20 Amps Max Sense Voltage: 300 Vac AC CURRENT SWITCHES RIBMXRF 4.00 Track Mount Solid Ring Remote Fixed 3-150 Amp AC Sensor, Self-Powered RIBMXRA 4.00 Track Mount Solid Ring Remote Adjustable 3-150 Amp AC Sensor, Self-Powered Sensor Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 1% full scale · Vripple < 10m Vac Sensor Feedback Current Sensor Status Current Sensor Circuitry Not Used Wire Being Monitored AXR CT Sensor Feedback Current Sensor Status Current Sensor Circuitry Not Used Wire Being Monitored AXR CT SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.700 x 4.000 x 1.250 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Sensor Type: External, with contact status Inside Diameter: .75 Outside Diameter: 2.28 Sensor Threshold: Fixed, 3 Amps (RIBMXRF) Adjustable, 3-150 Amps (RIBMXRA) Sensor Range: 3-150 Amps Max Sense Voltage: 600 Vac Sensor Contact Status: Current below threshold: Open / LED OFF Current above threshold: Closed / LED ON (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When sensor contact is off (open), leakage <30 uA @ 30Vac/dc · When sensor contact is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp 99 CURRENT SENSORS RELAY & AC CURRENT SWITCH COMBO RIBHX24BF Enclosed 20 Amp SPST-N/O Relay/AC Sensor Combination, with 24 Vac Coil Gry Sensor Feedback Current Sensor Status Gry Wht/Yel 24 Vac Wht/Yel Org - Comm Org - N/O RIBHX24BF-RD · Red housing RIBHX24BF-N4 · NEMA 4X housing, UL508 only Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Current Sensor Status Pink LED On = Current Over Trip Point (0.25 Amp) Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Sensor Type: Internal, with contact status Sensor Threshold: Fixed, .25 Amp Sensor Range: .25-20 Amps Sensor Feedback Output: Solid State Contact 30 Vac/dc, 100 mA Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Coil Current: 128 mA @ 24 Vac 71 mA @ 30 Vdc Coil Voltage Input: 24 Vac ; 50-60 Hz Drop Out = 3 Vac Pull In = 18 Vac 100 Functional Devices, Inc. | American Made. American Owned. CURRENT SENSORS RELAY & AC CURRENT SWITCH COMBOS RIBXLC Series Enclosed Relay/AC Sensor Combinations, SPDT with 10-30 Vac/dc Coil RIBXLCA, RIBXLCF, RIBXLCEA+ RIBXLCV, RIBXLCEV^ Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Blu - N/C Yel - Comm Org - N/O 10-30 Vac/dc Comm V V 0-10 Vdc 0-5 Vdc Comm Blu - N/C Yel - Comm Org - N/O Made in USA Meets "Buy American" of ARRA 2009 RIBXLCRA, RIBXLCRF+ RIBXLCJA, RIBXLCJF+ Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Current Sensor Circuitry Blu - N/C Yel - Comm Org - N/O Wire Being Monitored AXKT CT Gry Gry Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Current Sensor Circuitry Blu - N/C Yel - Comm Org - N/O Wire Being Monitored AXGT CT Gry Gry RIBXLCA SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc + Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp ^ Sensor Feedback Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 3% full scale · Vripple < 10m Vac Notes: · Models AXKT and AXGT CT remotes do not have contact closure circuitry and only work in conjunction with RIBXLCR and RIBXLCJ models, respectively. RIBXLC SERIES SELECTION GUIDE Model# Sensing Range Type * Threshold RIBXLCF .50-10 Amps Internal w/ contact status Fixed, .50 Amp RIBXLCA .50-10 Amps Internal w/ contact status Adjustable RIBXLCV 0-10 Amps Internal w/ voltage output Analog RIBXLCRF 1.25-150 Amps External w/ contact status Fixed, 1.25 Amp RIBXLCRA 1.25-150 Amps External w/ contact status Adjustable RIBXLCJF 3-150 Amps External w/ contact status Fixed, 3 Amp RIBXLCJA 3-150 Amps External w/ contact status Adjustable RIBXLCEA .125-5 Amps Internal w/ contact status Adjustable RIBXLCEV 0-5 Amps Internal w/ voltage output Analog Sensor Output Solid State Contact 30 Vac/dc, 0.4 Amp Solid State Contact 30 Vac/dc, 0.4 Amp 0-5 Vdc 0-10 Vdc Solid State Contact 30 Vac/dc, 0.4 Amp Solid State Contact 30 Vac/dc, 0.4 Amp Solid State Contact 30 Vac/dc, 0.4 Amp Solid State Contact 30 Vac/dc, 0.4 Amp Solid State Contact 30 Vac/dc, 0.4 Amp 0-5 Vdc 0-10 Vdc Remote Style Model AXKT: (Solid Core Remote CT) Model AXKT: (Solid Core Remote CT) Model AXGT: (Split Core Remote CT) Model AXGT: (Split Core Remote CT) Resistive Contact Ratings 10 Amp 10 Amp 10 Amp 10 Amp 10 Amp Resistive @ 120-277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) 10 Amp 10 Amp 10 Amp 5 Amp 5 Amp 5 Amp Resistive @ 277 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 268 VA Pilot Duty @ 277 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 175 VA Pilot Duty @ 277 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) * = Internal current sensor monitors current through common contact of relay. (800) 888-5538 | www.functionaldevices.com 101 RELAY & AC CURRENT SWITCH COMBOS RIBXLS Series Enclosed Relay/AC Sensor Combinations, SPST + Override with 10-30 Vac/dc Coil RIBXLSA, RIBXLSF, (RIBXLSEA*)+ RIBXLSV, (RIBXLSEV*)^ Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Selectable Jumper Wire Org* CLOSED OPEN AUTO Org* *Org wires will be Gry 10-30 Vac/dc Comm V V 0-10 Vdc 0-5 Vdc Comm Selectable Jumper Wire Org* CLOSED OPEN AUTO Org* *Org wires will be Gry Made in USA Meets "Buy American" of ARRA 2009 CURRENT SENSORS RIBXLSRA, RIBXLSRF+ Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Current Sensor Circuitry Selectable Jumper Wire Org CLOSED Org OPEN AUTO Wire Being Monitored AXKT CT Gry Gry RIBXLSJA, RIBXLSJF+ Sensor Feedback Current Sensor Status 10-30 Vac/dc Comm Current Sensor Circuitry Selectable Jumper Wire Org CLOSED Org OPEN AUTO Wire Being Monitored AXGT CT Gry Gry RIBXLSA SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc + Sensor Contact: · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp ^ Sensor Feedback Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 3% full scale · Vripple < 10m Vac Notes: · Normally Open or Normally Closed selected by yellow jumper wire · Models AXKT and AXGT CT remotes do not have contact closure circuitry and only work in conjunction with RIBXLSR and RIBXLSJ models, respectively. RIBXLS SERIES SELECTION GUIDE Model# Sensing Range Type * Threshold RIBXLSF .50-10 Amps Internal w/ contact status Fixed, .50 Amp RIBXLSA .50-10 Amps Internal w/ contact status Adjustable RIBXLSV 0-10 Amps Internal w/ voltage output Analog RIBXLSRF 1.25-150 Amps External w/ contact status Fixed, 1.25 Amp RIBXLSRA 1.25-150 Amps External w/ contact status Adjustable RIBXLSJF 3-150 Amps External w/ contact status Fixed, 3 Amp RIBXLSJA 3-150 Amps External w/ contact status Adjustable Sensor Output Solid State Contact 30 Vac/dc, 0.4 Amp Solid State Contact 30 Vac/dc, 0.4 Amp 0-5 Vdc 0-10 Vdc Solid State Contact 30 Vac/dc, 0.4 Amp Solid State Contact 30 Vac/dc, 0.4 Amp Solid State Contact 30 Vac/dc, 0.4 Amp Solid State Contact 30 Vac/dc, 0.4 Amp RIBXLSEA .125-5 Amps Internal w/ contact status Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp RIBXLSEV 0-5 Amps Internal w/ voltage output Analog 0-5 Vdc 0-10 Vdc * = Internal current sensor monitors current through common contact of relay. Remote Style Model AXKT: (Solid Core Remote) Model AXKT: (Solid Core Remote) Model AXGT: (Split Core Remote) Model AXGT: (Split Core Remote) Resistive Contact Ratings 10 Amp 10 Amp 10 Amp 10 Amp 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) 10 Amp 10 Amp 10 Amp 5 Amp 5 Amp 5 Amp Resistive @ 277 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 268 VA Pilot Duty @ 277 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 175 VA Pilot Duty @ 277 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) 102 Functional Devices, Inc. | American Made. American Owned. RELAY & AC CURRENT SWITCH COMBOS RIBX24 Series Enclosed 20 Amp Relay/AC Sensor Combinations, with 24 Vac/dc Coil RIBX24BA, RIBX24BF+ RIBX24BV^ Sensor Feedback Current Sensor Status 24 Vac/dc Comm Blu - N/C Yel - Comm Org - N/O 24 Vac/dc Comm 0-10 Vdc 0-5 Vdc Comm Blu - N/C Yel - Comm Org - N/O Made in USA Meets "Buy American" of ARRA 2009 V V V V CURRENT SENSORS RIBX24SBA, RIBX24SBF+ RIBX24SBV^ Sensor Feedback Current Sensor Status 24 Vac/dc Comm Selectable Jumper Wire Org CLOSED Org OPEN AUTO 24 Vac/dc Comm SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No 0-10 Vdc 0-5 Vdc Comm Selectable Jumper Wire Org CLOSED Org OPEN AUTO RIBX24SBA Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Sensor Contact: + · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Sensor Feedback Output: ^ · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 1% full scale · Vripple < 10m Vac RIBX24 SERIES SELECTION GUIDE Model# Sensing Range Type * Threshold Sensor Output RIBX24BF Internal w/ .50-20 Amps contact status Fixed, .50 Amp Solid State Contact 30 Vac/dc, 0.4 Amp RIBX24BA Internal w/ .50-20 Amps contact Adjustable status Solid State Contact 30 Vac/dc, 0.4 Amp RIBX24BV Internal w/ 0-20 Amps voltage output Analog 0-5 Vdc 0-10 Vdc Internal w/ RIBX24SBF .50-20 Amps contact status Fixed, .50 Amp Solid State Contact 30 Vac/dc, 0.4 Amp Internal w/ RIBX24SBA .50-20 Amps contact Adjustable status Solid State Contact 30 Vac/dc, 0.4 Amp Internal w/ RIBX24SBV 0-20 Amps voltage output Analog 0-5 Vdc 0-10 Vdc Resistive 20 Amp 20 Amp 20 Amp Override Switch Contact Ratings 20 Amp Resistive @ 277 Vac No 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac No 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac No Notes 20 Amp 20 Amp 20 Amp 20 Amp Resistive @ 277 Vac Yes 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) Yes 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac Yes 1 HP @ 120 Vac · Normally Open or Normally Closed selected by yellow jumper wire * = Internal current sensor monitors current through common contact of relay. (800) 888-5538 | www.functionaldevices.com 103 RELAY & AC CURRENT SWITCH COMBOS RIBX243PF Enclosed Internal Fixed .50-20 Amp AC Sensor + Relay 20 Amp 3PST-N/O with 24 Vac/dc Coil RIBX243PA Enclosed Internal Adjustable .50-20 Amp AC Sensor + Relay 20 Amp 3PST-N/O with 24 Vac/dc Coil Blu - N/O Blu - N/O Blu - N/O Blu - N/O Made in USA Meets "Buy American" of ARRA 2009 Yel - N/O Yel - N/O Yel - N/O Yel - N/O 24 Vac/dc Comm Sensor Feedback Current Sensor Status (Orange WIres) Org - N/O Org - N/O 24 Vac/dc Comm Sensor Feedback Current Sensor Status (Orange WIres) Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Sensor Type: Internal, with contact status Current sensing on orange wires Sensor Threshold: Fixed, .5 Amps (RIBX243PF) Adjustable, .50-20 Amps (RIBX243PA) Sensor Range: .50-20 Amps Sensor Contact: · Solid State Contact · 30 Vac/dc, .4 Amp Max. · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Notes: · Order Normally Closed by adding "-NC" to end of model number CURRENT SENSORS RELAY & AC TRANSDUCER COMBO RIBX243PV Enclosed Internal 0-20 Amp to 0-10 Vdc DC Transducer + Relay 20 Amp 3PST with 24 Vac/dc Coil Blu - N/O Blu - N/O Yel - N/O Yel - N/O V 24 Vac/dc Comm Comm 0-10 Vdc Org - N/O Org - N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Contact Ratings: Sensor Type: Internal, with voltage output. Current Expected Relay Life: 10 million cycles minimum mechanical 20 Amp Resistive @ 300 Vac, 28 Vdc sensing on orange wires Operating Temperature: -30 to 140° F 20 Amp Ballast @ 277-480 Vac Sensor Range: 0-20 Amps Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wire Length: 16, 600V Rated Approvals: UL Listed, UL916, C-UL Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase Sensor Feedback Output: · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 1% full scale · Vripple < 10m Vac California State Fire Marshal, CE, RoHS 1466 VA Pilot Duty @ 240 Vac, 3 Phase Housing Rating: UL Accepted for Use in Plenum, NEMA 1 2112 VA Pilot Duty @ 480 Vac, 3 Phase Notes: Gold Flash: No Heavy Pilot Duty @ 600 Vac · Order Normally Closed by adding "-NC" to end of Override Switch: No 7.5 HP @ 480 Vac, 3 Phase model number 5 HP @ 240 Vac, 3 Phase · Can be ordered with 0-5 Vdc voltage output - Coil Current: Coil Voltage Input: 3 HP @ 480-600 Vac, 1 Phase Consult factory. 210 mA @ 24 Vac 24 Vac/dc ; 50-60 Hz 2 HP @ 240-277 Vac, 1 Phase 154 mA @ 30 Vdc Drop Out = 3 Vac / 3.8 Vdc 1 HP @ 120 Vac, 1 Phase 104 Pull In = 20 Vac / 22 Vdc Functional Devices, Inc. | American Made. American Owned. RELAY & AC CURRENT SWITCH COMBOS RIBMX24 Series 4.00 Track Mount 20 Amp Relay/AC Sensor Combinations, with 24 Vac/dc Coil RIBMX24BA, RIBMX24BF+ RIBMX24BV^ Sensor Feedback Current Sensor Status 24 Vac/dc Comm Comm N/O N/C 0-10 Vdc V 0-5 Vdc V Comm 24 Vac/dc Comm Comm N/O N/C Made in USA Meets "Buy American" of ARRA 2009 CURRENT SENSORS RIBMX24SBA, RIBMX24SBF+ Sensor Feedback Current Sensor Status 24 Vac/dc Comm Selectable Jumper Wire Not Used CLOSED OPEN AUTO RIBMX24SBV^ 0-10 Vdc V 0-5 Vdc V Comm 24 Vac/dc Comm Selectable Jumper Wire Not Used CLOSED OPEN AUTO SPECIFICATIONS FUNCTIONAL DEVICES CERTIFIED FOR USE WITH ECMS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: Red LED On = Activated Dimensions: 2.95 x 4.00 x 1.25 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Sensor Contact: + · When current sensor status is off (open), leakage <30 uA @ 30Vac/dc · When current sensor status is on (closed), voltage drop < .3 Vac/dc @ .1 Amp < 1.6 Vac/dc @ .4 Amp Sensor Feedback Output: ^ · Voltage output is proportional to current sensor range. · Min. Input Impedance = 30K ohms · Accuracy +/ 1% full scale · Vripple < 10m Vac RIBMX24 SERIES SELECTION GUIDE Model# Sensing Range Type Threshold Sensor Output Internal w/ RIBMX24BF ECMS .50-20 Amps contact status Fixed, .50 Amp Solid State Contact 30 Vac/dc, 0.4 Amp Internal w/ RIBMX24BA ECMS .50-20 Amps contact status Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp RIBMX24BV Internal w/ 0-20 Amps voltage output Analog 0-5 Vdc 0-10 Vdc Internal w/ RIBMX24SBF ECMS .50-20 Amps contact status Fixed, .50 Amp Solid State Contact 30 Vac/dc, 0.4 Amp Internal w/ RIBMX24SBA ECMS .50-20 Amps contact status Adjustable Solid State Contact 30 Vac/dc, 0.4 Amp RIBMX24SBV Internal w/ 0-20 Amps voltage output Analog 0-5 Vdc 0-10 Vdc Resistive Override Switch Contact Type Contact Ratings 20 Amp No 20 Amp No 20 Amp No SPDT SPDT SPDT 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Notes 20 Amp Yes 20 Amp Yes 20 Amp Yes SPST SPST SPST 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac · Normally Open or Normally Closed selected by yellow jumper wire ECMS = FDI Certified for use with electronically commutated motors (800) 888-5538 | www.functionaldevices.com 105 Notes CURRENT SENSORS 106 Functional Devices, Inc. | American Made. American Owned. POWER SUPPLIES AC | DC Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). · Class 2 · On/off control · Overcurrent protection · LED power indicator · High/low voltage separation · 120Vac convenience outlets Perfect for VAV Applications: PSH500A and PSH300A · 5 or 3 isolated 100 VA outputs · UL Listed Class 2 · On/Off circuit breaker switch for each output · Fully enclosed perfect for central location POWER SUPPLIES AC POWER SUPPLIES MODEL # PSC40AB10 · 1 PSC100AB10 · 1 PSH40A Series · 1 PSH75A Series · PSH100A Series · 1 PSH40AB10-EXT2 · 1 PSH100AB10-EXT2 · 1 PSH40A40A Series · 1 PSH40A75A Series · · PSH40A100A Series 1 PSH75A75A Series · PSH75A100A Series · · PSH100A100A Series 1 CTRL-PS · 1 MHP3903100AB10 · MHP3903100A100AB10 · PSH500A · 1 PSH300A · 1 PSH200A · PSMN500A · 1 PSMN300A · 1 PSMN200A · PSH500A-LVC 3 · 1 PSH300A-LVC 3 · 1 PSH200A-LVC 3 · PSH500AB10-LVC 3 · 1 PSH300AB10-LVC 3 · 1 PSH200AB10-LVC 3 · PSB40AB10 · 1 PSB100AB10 · 1 PSMN40AS · 1 PSMN40A · 1 TRANSFORMER(S) 40 VA 100 VA 40 VA 75 VA 100 VA 40 VA 100 VA 40 VA, 40 VA 40 VA, 75 VA 40 VA, 100 VA 75 VA, 75 VA 75 VA, 100 VA 100VA, 100VA 40 VA 100 VA 100VA, 100VA 500 VA w/ five 100 VA Outputs 300 VA w/ three 100 VA Outputs 200 VA w/ five 40 VA Outputs 500 VA w/ five 100 VA Outputs 300 VA w/ three 100 VA Outputs 200 VA w/ five 40 VA Outputs 500 VA w/ five 100 VA Outputs 300 VA w/ three 100 VA Outputs 200 VA w/ five 40 VA Outputs 500 VA w/ five 100 VA Outputs 300 VA w/ three 100 VA Outputs 200 VA w/ five 40 VA Outputs 40 VA 100 VA 40 VA 40 VA INPUT POWER 120 Vac 120 Vac 120 Vac Multi-Tap 2 120 Vac 120 Vac 120 Vac 120 Vac, 120 Vac 120 Vac, Multi-Tap 2 120 Vac, 120 Vac Multi-Tap, Multi-Tap 2 Multi-Tap 2 ,120 Vac 120 Vac, 120 Vac 120 Vac 120 Vac 120 Vac 480/277/240/120 Vac 480/277/240/120 Vac 480/347/277/240/120 Vac 480/277/240/120 Vac 480/277/240/120 Vac 480/347/277/240/120 Vac 480/277/240/120 Vac 480/277/240/120 Vac 480/347/277/240/120 Vac 480/277/240/120 Vac 480/277/240/120 Vac 480/347/277/240/120 Vac 120 Vac 120 Vac 120 Vac 120 Vac HEIGHT 6.250 6.250 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 14.500 24.500 24.500 12.125 12.125 12.125 11.330 11.330 11.330 12.125 11.330 11.330 12.125 11.330 11.330 5.200 5.200 3.250 3.250 WIDTH 5.620 5.620 5.438 5.438 5.438 5.438 5.438 8.625 8.625 8.625 8.625 8.625 8.625 7.700 12.500 12.500 12.125 12.125 12.125 11.400 11.400 11.400 12.125 11.400 11.400 12.125 11.400 11.400 5.250 5.250 2.750 2.750 DEPTH 4.250 4.250 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 4.500 3.900 6.500 6.500 6.000 6.000 6.000 5.000 4.500 5.000 6.000 4.500 5.000 6.000 4.500 5.000 3.750 3.750 2.000 2.000 WEIGHT 4.40 lbs. 5.80 lbs. 3.10 lbs. 4.50 lbs. 4.60 lbs. 4.00 lbs. 4.00 lbs. 5.40 lbs. 6.80 lbs. 6.90 lbs. 8.40 lbs. 8.50 lbs. 8.60 lbs. 7.28 lbs. 30.65 lbs. 33.05 lbs. 30.16 lbs. 18.08 lbs. 18.60 lbs. 20.60 lbs. 12.38 lbs. 8.00 lbs. 32.30 lbs. 22.46 lbs. 20.30 lbs. 32.30 lbs. 22.12 lbs. 20.30 lbs. 2.18 lbs. 3.58 lbs. 1.60 lbs. 1.60 lbs. NOTES NEW NEW NEW NEW NEW NEW NEW SPEC PAGE 108 108 108 109 109 110 110 110 111 111 112 112 113 113 114 115 116 117 118 116 117 118 119 120 120 121 122 123 124 124 124 124 = Class 2 (UL Approved UL5085-3) : UL916 Energy Management USA & Canada 1 = UL508 Available 2 = 480/277/240/208/120 Vac 3 = High / Low Voltage Separation DC POWER SUPPLIES MODEL # PSP24DA VOLTAGE INPUT · 24 Vac PSH24DWB10 120 Vac PSH100A24DWB10 PSMN24DA · PSMN24DAS · PSM20A12DAS · PSM24A24DAS · PSM19A24DAS · PSMN40A24DS · 120 Vac 24 Vac 24 Vac 24 Vac 24 Vac 120 Vac 120 Vac VOLTAGE OUTPUT Adjustable 1.5-28 Vdc ; Non-Isolated Fixed 24 Vdc ; Isolated Fixed 24 Vdc ; Isolated + 100 VA, 24 Vac Adjustable 1.5-28 Vdc ; Non-Isolated Adjustable 1.5-28 Vdc ; Non-Isolated Adjustable 1.5-12 Vdc ; Isolated Adjustable 1.5-28 Vdc ; Isolated Adjustable 1.5-28 Vdc ; Isolated Fixed 24 Vdc ; Isolated OUTPUT CURRENT 300 mA 2.5 Amp 2.5 Amp 300 mA 300 mA 300 mA 300 mA 300 mA 1 Amp ON/OFF SWITCH · · · · · · · HEIGHT 2.300 4.000 4.000 1.750 1.750 4.000 4.000 4.000 5.000 WIDTH 3.200 5.438 5.438 2.750 2.750 2.750 2.750 2.750 2.750 DEPTH 1.800 4.500 4.500 1.500 1.500 1.625 1.625 1.625 2.000 WEIGHT .30 lbs. 2.98 lbs. 5.60 lbs. .20 lbs. .20 lbs. 1.10 lbs. 1.10 lbs. 1.10 lbs. 1.50 lbs. NOTES SPEC PAGE 125 125 126 126 126 127 127 127 128 = Class 2 (UL Approved UL5085-3) : UL916 Energy Management USA & Canada (800) 888-5538 | www.functionaldevices.com 107 AC POWER SUPPLY PSC40AB10 Enclosed Single 40 VA Power Supply, 120 to 24 Vac PSC100AB10 Enclosed Single 100 VA Power Supply, 120 to 24 Vac 120 Vac Convenience Outlet * Neutral 120 Vac Ground 120 Vac Aux. Output 5.620" 2.245" 3.900" Shown Without Cover Class 2 POWER SUPPLIES ON RESET OFF OFF LED Indicator Com 24 Vac 10 Amp Main Breaker/Switch 24 Vac Breaker 24 Vac On/O Switch Removable Access Plate * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 5.620" 6.250" 4.500" Shown With Cover Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Transformer: One 40 VA Split-Bobbin, Inherently Limited (PSC40AB10) One 100 VA Split-Bobbin, Circuit Breaker (PSC100AB10) Primary: 120 Vac Secondary: 24 Vac, w/ LED Indicator Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Mounting: Mounting plate included (as shown) Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508 for -IC models, C-UL, CE, RoHS Dimensions: 6.250 x 5.620 x 4.250 Weight: 4.40 lbs. (PSC40AB10), 5.80 lbs. (PSC100AB10) Notes: · To order without enclosure, see PSB40AB10 & PSB100AB10. · To order UL508, add "-IC" to end of model number. AC POWER SUPPLY PSH40A Series Enclosed Single 40 VA Power Supplies, 120 to 24 Vac Class 2 120 Vac Convenience Outlet * 5.438" 5.150" 4.500" Made in USA Meets "Buy American" of ARRA 2009 24 Vac Breaker 24 Vac ON OFF On/O Switch RESET LED Indicator OFF Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS ON 4.500" RESET OFF 4.250" OFF 5.150" PSH40A SERIES SELECTION GUIDE Model # PSH40A PSH40AN PSH40ANW PSH40AW PSH40AB10* PSH40ANB10* PSH40ANWB10* PSH40AWB10* 120 Vac Outlets · · · · Aux Output Wire · · · · Main Breaker on Input Power 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip External Terminal Strip Internal Wires Internal Wires External Terminal Strip External Terminal Strip Internal Wires Internal Wires Transformer: One 40 VA Split-Bobbin Input Wires: "B10 Models Only All Other Models Over Current Protection: Circuit Breaker Input Power Wires Primary Wires Frequency: 50/60 Hz BLK: 120 Vac BLK: 120 Vac 24 Vac ON/OFF: On / Off Switch & Breaker WHT: Neutral WHT: Common Main Breaker ON/OFF: Switch / Breaker (10 Amp) GRN: Ground (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground UL508 for -IC models, C-UL, CE, RoHS, ^ Special Seismic Certification of Output Wires: "B10 Models Only "W Models Only Equipment and Components: Auxiliary Output Transformer Output OSP-0201-10 BLU: 120 Vac WHT/YEL: 24 Vac Dimensions: 4.500 x 5.438 x 4.500 WHT/BLU: Common Weight: 4.00 lbs. 108 Functional Devices, Inc. | American Made. American Owned. Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · To order UL508, add "-IC" to end of model number. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/ OSP-0201-10.pdf AC POWER SUPPLY PSH75A Series Enclosed Single 75 VA Power Supplies, 480/277/240/208/120 to 24 Vac Class 2 120 Vac Convenience Outlet * 5.438" 5.150" 4.500" Made in USA Meets "Buy American" of ARRA 2009 24 Vac Breaker 24 Vac ON OFF On/O Switch RESET LED Indicator OFF Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS ON 4.500" RESET OFF 4.250" OFF 5.150" PSH75A SERIES SELECTION GUIDE Model # PSH75A PSH75AN PSH75ANW PSH75AW PSH75AB10* PSH75ANB10* PSH75ANWB10* PSH75AWB10* 120 Vac Outlets · · · · Aux Output Wire · · · · Main Breaker on Input Power 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip External Terminal Strip Internal Wires Internal Wires External Terminal Strip External Terminal Strip Internal Wires Internal Wires Transformer: One 75 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 x 5.438 x 4.500 Weight: 4.500 lbs. Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac All Other Models Primary Wires** GRY: 480 Vac BRN: 277 Vac ORG: 240 Vac RED: 208 Vac WHT: 120 Vac BLK: Common "W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/ OSP-0201-10.pdf · All primary voltages other than 120 Vac will result in the disabling of convenience outlets.** POWER SUPPLIES AC POWER SUPPLY PSH100A Series Enclosed Single 100 VA Power Supplies, 120 to 24 Vac Class 2 120 Vac Convenience Outlet * 5.438" 5.150" 4.500" Made in USA Meets "Buy American" of ARRA 2009 24 Vac Breaker 24 Vac ON OFF On/O Switch RESET LED Indicator OFF Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS ON 4.500" RESET OFF 4.250" OFF 5.150" PSH100A SERIES SELECTION GUIDE Model # PSH100A PSH100AN PSH100ANW PSH100AW PSH100AB10* PSH100ANB10* PSH100ANWB10* PSH100AWB10* 120 Vac Outlets · Aux Output Wire Main Breaker on Input Power · · · 10 Amp Switch / Breaker · 10 Amp Switch / Breaker · 10 Amp Switch / Breaker · · 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip External Terminal Strip Internal Wires Internal Wires External Terminal Strip External Terminal Strip Internal Wires Internal Wires Transformer: One 100 VA Split-Bobbin Input Wires: "B10 Models Only All Other Models Over Current Protection: Circuit Breaker Input Power Wires Primary Wires Frequency: 50/60 Hz BLK: 120 Vac BLK: 120 Vac 24 Vac ON/OFF: On / Off Switch & Breaker WHT: Neutral WHT: Common Main Breaker ON/OFF: Switch / Breaker (10 Amp) GRN: Ground (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground UL508 for -IC models, C-UL, CE, RoHS, Spe- Output Wires: "B10 Models Only "W Models Only cial ^ Seismic Certification of Equipment Auxiliary Output Transformer Output and Components: OSP-0201-10 BLU: 120 Vac WHT/YEL: 24 Vac Dimensions: 4.500 x 5.438 x 4.500 WHT/BLU: Common Weight: 4.600 lbs. (800) 888-5538 | www.functionaldevices.com Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · To order UL508, add "-IC" to end of model number. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/ OSP-0201-10.pdf 109 AC POWER SUPPLY PSH40AB10-EXT2 Enclosed Single 40 VA Power Supply, 120 to 24 Vac, with Three Foot Extension Cord PSH100AB10-EXT2 Enclosed Single 100 VA Power Supply, 120 to 24 Vac, with Three Foot Extension Cord Class 2 Made in USA Meets "Buy American" of ARRA 2009 Extension Cord 120 Vac Convenience Outlet * 24 Vac Breaker 24 Vac ON OFF On/O Switch RESET LED Indicator OFF Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch 36.000" 5.438" 5.150" ON 4.500" RESET OFF 4.250" OFF 4.500" POWER SUPPLIES 4.500" 4.250" * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 5.150" SPECIFICATIONS Transformer: One 40 VA (PSH40AB10-EXT2) or One 100 VA (PSH100AB10-EXT2) Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 x 5.438 x 4.500 Weight: 4.00 lbs. AC POWER SUPPLY Input Wires: Powercord BLK: 120 Vac WHT: Neutral GRN: Ground Output Wire: Auxiliary Load Output BLU: 120 Vac 9 Amp, max. PLUGS DIRECTLY INTO WIRED OUTLET BOX FOR USE ABOVE FALSE CEILINGS OR IN CONTROL PANELS Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. PSH40A40A Series Enclosed Dual 40 VA Power Supplies, 120 to 24 Vac 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 8.625" 8.250" 24 Vac Breaker 24 Vac ON OFF RESET ON OFF On/O Switch ON OFF ON OFF RESET LED Indicator OFF OFF Com 24 Vac Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch 8.250" * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS 4.500" Class 2 Made in USA Meets "Buy American" of ARRA 2009 PSH40A40A SERIES SELECTION GUIDE Model # PSH40A40A PSH40A40AN PSH40A40ANW PSH40A40AW PSH40A40AB10* PSH40A40ANB10* PSH40A40ANWB10* PSH40A40AWB10* 120 Vac Outlets · · · · Aux Output Wire · · · · Main Breaker on Input Power 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip External Terminal Strip Internal Wires Internal Wires External Terminal Strip External Terminal Strip Internal Wires Internal Wires Transformer: Two 40 VA Split-Bobbin Input Wires: "B10 Models Only All Other Models Over Current Protection: Circuit Breaker Input Power Wires Primary Wires Frequency: 50/60 Hz BLK: 120 Vac BLK: 120 Vac 24 Vac ON/OFF: On / Off Switch & Breaker WHT: Neutral WHT: Common Main Breaker ON/OFF: Switch / Breaker (10 Amp) GRN: Ground (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground UL508 for -IC models, C-UL, CE, RoHS, Spe- Output Wires: "B10 Models Only "W Models Only cial ^ Seismic Certification of Equipment Auxiliary Output Transformer Output and Components: OSP-0201-10 BLU: 120 Vac WHT/YEL: 24 Vac Dimensions: 4.500 x 8.625 x 4.500 WHT/BLU: Common 110 Weight: 5.400 lbs. Functional Devices, Inc. | American Made. American Owned. Notes: · All dual models: Model number denotes location of transformer within enclosure. PSH40A40A Left side Right side · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · To order UL508, add "-IC" to end of model number. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/ OSP-0201-10.pdf AC POWER SUPPLY PSH40A75A Series Enclosed 40 VA (120 to 24 Vac) and 75 VA (Multi-Tap to 24 Vac) Power Supplies Class 2 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 8.625" 8.250" 4.500" Made in USA Meets "Buy American" of ARRA 2009 ON OFF Com 24 Vac 24 Vac Breaker 24 Vac ON OFF On/O Switch RESET LED Indicator OFF Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch ON ON OFF OFF RESET OFF 8.250" * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS 4.500" 4.250" PSH40A75A SERIES SELECTION GUIDE Model # PSH40A75A PSH40A75AN PSH40A75ANW PSH40A75AW PSH40A75AB10* PSH40A75ANB10* PSH40A75ANWB10* PSH40A75AWB10* 120 Vac Outlets · · · · Aux Output Wire Main Breaker on Input Power · 10 Amp Switch / Breaker · 10 Amp Switch / Breaker · 10 Amp Switch / Breaker · 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip External Terminal Strip Internal Wires Internal Wires External Terminal Strip External Terminal Strip Internal Wires Internal Wires Transformer: One 40 VA and One 75 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 x 8.625 x 4.500 Weight: 6.800 lbs. Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac All Other Models 40 VA Primary Wires BLK: 120 Vac WHT: Common 75 VA Primary Wires** GRY: 480 Vac BRN: 277 Vac ORG: 240 Vac RED: 208 Vac WHT: 120 Vac BLK: Common "W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common Notes: · All dual models: Model number denotes location of transformer within enclosure. PSH40A75A Left side Right side · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/ OSP-0201-10.pdf · All primary voltages other than 120 Vac will result in the disabling of convenience outlets.** POWER SUPPLIES AC POWER SUPPLY PSH40A100A Series Enclosed 40 VA and 100 VA Power Supplies, 120 to 24 Vac 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 8.625" 8.250" 24 Vac Breaker 24 Vac ON OFF ON OFF On/O Switch ON OFF ON OFF RESET RESET LED Indicator OFF OFF Com 24 Vac Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch 8.250" * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS 4.500" 4.250" 4.500" Class 2 Made in USA Meets "Buy American" of ARRA 2009 PSH40A100A SERIES SELECTION GUIDE Model # PSH40A100A PSH40A100AN PSH40A100ANW PSH40A100AW PSH40A100AB10* PSH40A100ANB10* PSH40A100ANWB10* PSH40A100AWB10* 120 Vac Outlets · · · · Aux Output Wire · · · · Main Breaker on Input Power 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip External Terminal Strip Internal Wires Internal Wires External Terminal Strip External Terminal Strip Internal Wires Internal Wires Transformer: One 40 VA and One 100 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508 for -IC models, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 x 8.625 x 4.500 Weight: 6.900 lbs. Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac All Other Models Primary Wires BLK: 120 Vac WHT: Common "W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common (800) 888-5538 | www.functionaldevices.com Notes: · All dual models: Model number denotes location of transformer within enclosure. PSH40A100A Left side Right side · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · To order UL508, add "-IC" to end of model number. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/ OSP-0201-10.pdf 111 AC POWER SUPPLY PSH75A75A Series Enclosed Dual 75 VA Power Supplies, 480/277/240/208/120 to 24 Vac Class 2 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 8.625" 8.250" 4.500" Made in USA Meets "Buy American" of ARRA 2009 24 Vac Breaker ON OFF 24 Vac ON OFF On/O Switch ON OFF RESET LED Indicator OFF Com 24 Vac Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS ON OFF RESET OFF 8.250" 4.500" 4.250" PSH75A75A SERIES SELECTION GUIDE Model # PSH75A75A PSH75A75AN PSH75A75ANW PSH75A75AW PSH75A75AB10* PSH75A75ANB10* PSH75A75ANWB10* PSH75A75AWB10* 120 Vac Outlets · · · · Aux Output Wire · · · · Main Breaker on Input Power 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip External Terminal Strip Internal Wires Internal Wires External Terminal Strip External Terminal Strip Internal Wires Internal Wires Transformer: Two 75 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 x 8.625 x 4.500 Weight: 8.400 lbs. Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac All Other Models Primary Wires** GRY: 480 Vac BRN: 277 Vac ORG: 240 Vac RED: 208 Vac WHT: 120 Vac BLK: Common "W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common Notes: · All dual models: Model number denotes location of transformer within enclosure. PSH75A75A Left side Right side · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/ OSP-0201-10.pdf · All primary voltages other than 120 Vac will result in the disabling of convenience outlets.** POWER SUPPLIES AC POWER SUPPLY PSH75A100A Series Enclosed 75 VA (Multi-Tap to 24 Vac) and 100 VA (120 to 24 Vac) Power Supplies 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 24 Vac Breaker 24 Vac ON OFF RESET ON OFF On/O Switch ON OFF LED Indicator OFF Com 24 Vac Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch 8.625" 8.250" ON OFF RESET OFF 8.250" * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 4.500" 4.250" 4.500" Class 2 Made in USA Meets "Buy American" of ARRA 2009 PSH75A100A SERIES SELECTION GUIDE Model # PSH75A100A PSH75A100AN PSH75A100ANW PSH75A100AW PSH75A100AB10* PSH75A100ANB10* PSH75A100ANWB10* PSH75A100AWB10* 120 Vac Outlets · · · · Aux Output Wire · · · · Main Breaker on Input Power 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip External Terminal Strip Internal Wires Internal Wires External Terminal Strip External Terminal Strip Internal Wires Internal Wires SPECIFICATIONS Transformer: One 75 VA and Input Wires: "B10 Models Only All Other Models One 100 VA Split-Bobbin Input Power Wires 75 VA Primary Wires** Over Current Protection: Circuit Breaker BLK: 120 Vac GRY: 480 Vac Frequency: 50/60 Hz WHT: Neutral BRN: 277 Vac 24 Vac ON/OFF: On / Off Switch & Breaker GRN: Ground ORG: 240 Vac Main Breaker ON/OFF: Switch / Breaker (10 Amp) RED: 208 Vac (Kills power to entire unit: Outlets, Outlet Wires WHT: 120 Vac Aux. Output, & Transformer)* BLK: 120 Vac BLK: Common Total Combined Output 9A WHT: Neutral 100 VA Primary Wires Approvals: Class 2 (UL Approved UL5085-3), GRN: Ground BLK: 120 Vac UL916, C-UL, CE, RoHS, Special WHT: Common ^ Seismic Certification of Equipment and Components: OSP-0201-10 Output Wires: "B10 Models Only "W Models Only Dimensions: 4.500 x 8.625 x 4.500 Auxiliary Output Transformer Output Weight: 8.500 lbs. BLU: 120 Vac WHT/YEL: 24 Vac 112 WHT/BLU: Common Functional Devices, Inc. | American Made. American Owned. Notes: · All dual models: Model number denotes location of transformer within enclosure. PSH75A100A Left side Right side · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/ OSP-0201-10.pdf · All primary voltages other than 120 Vac will result in the disabling of convenience outlets.** AC POWER SUPPLY PSH100A100A Series Enclosed Dual 100 VA Power Supplies, 120 to 24 Vac Class 2 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 8.625" 8.250" 4.500" Made in USA Meets "Buy American" of ARRA 2009 24 Vac Breaker 24 Vac ON OFF ON OFF On/O Switch ON OFF RESET LED Indicator OFF Com 24 Vac Com 24 Vac 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. SPECIFICATIONS ON OFF RESET OFF 8.250" 4.500" 4.250" PSH100A100A SERIES SELECTION GUIDE Model # PSH100A100A PSH100A100AN PSH100A100ANW PSH100A100AW PSH100A100AB10* PSH100A100ANB10* PSH100A100ANWB10* PSH100A100AWB10* 120 Vac Outlets · · · · Aux Output Wire Main Breaker on Input Power · 10 Amp Switch / Breaker · 10 Amp Switch / Breaker · 10 Amp Switch / Breaker · 10 Amp Switch / Breaker Secondary Configuration External Terminal Strip External Terminal Strip Internal Wires Internal Wires External Terminal Strip External Terminal Strip Internal Wires Internal Wires Transformer: Two 100 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508 for -IC models, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Dimensions: 4.500 x 8.625 x 4.500 Weight: 8.600 lbs. Input Wires: "B10 Models Only Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: "B10 Models Only Auxiliary Output BLU: 120 Vac All Other Models Primary Wires BLK: 120 Vac WHT: Common "W Models Only Transformer Output WHT/YEL: 24 Vac WHT/BLU: Common Notes: · All dual models: Model number denotes location of transformer within enclosure. PSH100A100A Left side Right side · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · To order UL508, add "-IC" to end of model number. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/ OSP-0201-10.pdf AC POWER SUPPLY CTRL-PS Kit Consisting of Model PSMN40AS and a Metal Enclosure 120 Vac Line Input 7.70" 5.70" Made in USA Meets "Buy American" of ARRA 2009 POWER SUPPLIES 14.50" 11.50" 14.50" ON OFF SPECIFICATIONS 24 Vac Device Output Transformer: One 40 VA Primary: 120 Vac Secondary: 24 Vac, isolated Frequency: 50/60 Hz Overload Protection: Inherently Limited Status: LED On = Activated ON/OFF Switch: 2 Position Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS (PSMN40AS) UL916, C-UL, CE, RoHS (MH1000 Series) Dimensions: 14.50 x 7.70 x 3.90 Weight: 7.28 lbs. Housing: NEMA 1 Metal Enclosure with screw cover 3.90" 7.70" Shown With Cover Notes: · Track mounted power supply may be ordered separately as model PSMN40AS. · 40 VA power supply mounted in MT212-4 track, high/low voltage barrier and 8.75 of 35 mm top hat DIN rail for mounting of desired controller in one metal enclosure. · Controller must be 9.50 x 6.75 x 3.50 or smaller with DIN rail mounting capability, or 9.50 x 6.75 x 3.125 without DIN rail mounting capability. · Controller not included. GREAT FOR ZONE & NETWORK CONTROLLERS (800) 888-5538 | www.functionaldevices.com 113 AC POWER SUPPLY MHP3903100AB10 Enclosed Single100 VA Power Supply with Subpanel: Models MH3900 + SP3803S + PS100AB10 10.60" 12.50" MHP3904100AB10 Enclosed Single100 VA Power Supply with Subpanel: Models MH3900 + SP3804S + PS100AB10 1111.7.75050" " 1100.7.57005" " 99..000000"" .050.050"0" 5.15" 5.438" 5.150" 4.50" 4.500" 4.50" 4.25" ON 4.500" RESET OFF 4.250" OFF 5.15" 5.150" Class 2 Made in USA Meets "Buy American" of ARRA 2009 1 199..000000"" 22.00" 24.50" 9.90.0000"0" 88.5.05000" " 6.50" 12.50" 0.5.50000" " POWER SUPPLY (PS100AB10) Transformer: One 100 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 x 8.625 x 4.500 Weight: 4.600 lbs. Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: Auxiliary Output BLU: 120 Vac Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13 SELECTION GUIDE Model # MHP3903100AB10 MHP3904100AB10 Sub-Panel Polymetal Perforated Steel POLYMETAL SUB-PANEL (SP3803S) Mounting Area: 223.25 square Approvals: Plenum Rated Dimensions: 19.00" x 11.75" Weight: 1.705 lbs. PERFORATED STEEL SUB-PANEL (SP3804S) Mounting Area: 223.25 square Approvals: Plenum Rated Dimensions: 19.00" x 11.75" Weight: 2.94 lbs. METAL HOUSING (MH3900) Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 12.50" (W) x 24.50" (H) x 6.50" (D) Weight: 24.30 lbs. POWER SUPPLIES 114 Functional Devices, Inc. | American Made. American Owned. AC POWER SUPPLY MHP3903100A100AB10 Enclosed Dual 100 VA Power Supplies with Subpanel: Models MH3900 + SP3803S + PS100A100AB10 10.60" 12.50" MHP3904100A100AB10 Enclosed Dual 100 VA Power Supplies with Subpanel: Models MH3900 + SP3804S + PS100A100AB10 1111.7.75050" " 1100.7.57005" " 99..000000"" ON OFF .050.050"0" 8.625" 88..22505" " ON OFF RESET OFF 88.2.2550"" 44..5050"0" 44..2520"5" 44..55000" " Class 2 Made in USA Meets "Buy American" of ARRA 2009 1 199..000000"" 22.00" 24.50" 9.90.0000"0" 88.5.05000" " 6.50" 12.50" 0.5.50000" " POWER SUPPLY (PS100A100AB10) Transformer: Two 100 VA Split-Bobbin Over Current Protection: Circuit Breaker Frequency: 50/60 Hz 24 Vac ON/OFF: On / Off Switch & Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 4.500 x 8.625 x 4.500 Weight: 7.000 lbs. Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Outlet Wires BLK: 120 Vac WHT: Neutral GRN: Ground Output Wires: Auxiliary Output BLU: 120 Vac Notes: · Output derating may exceed 20% due to elevated ambient temperature or heat buildup in device over time. · Design is in accordance with ASCE 7-05 Chapter 13 SELECTION GUIDE Model # MHP3903100A100AB10 MHP3904100A100AB10 Sub-Panel Polymetal Perforated Steel POLYMETAL SUB-PANEL (SP3803S) Mounting Area: 223.25 square Approvals: Plenum Rated Dimensions: 19.00" x 11.75" Weight: 1.705 lbs. PERFORATED STEEL SUB-PANEL (SP3804S) Mounting Area: 223.25 square Approvals: Plenum Rated Dimensions: 19.00" x 11.75" Weight: 2.94 lbs. METAL HOUSING (MH3900) Construction: 14 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Dimensions: 12.50" (W) x 24.50" (H) x 6.50" (D) Weight: 24.30 lbs. POWER SUPPLIES (800) 888-5538 | www.functionaldevices.com 115 POWER SUPPLIES User Connections AC POWER SUPPLY PSH500A Enclosed 500VA Power Supply with Five 100VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac PSMN500A Open Style 500VA Power Supply with Five 100VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac 480 277 240 120 COM ON 1 OFF ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5 24V COM 24V COM 24V COM 24V COM 24V COM PSH500A Shown With Cover PSH500A Shown Without Cover Class 2 Made in USA Meets "Buy American" of ARRA 2009 Switch PSMN500A Indicator SPECIFICATIONS Breaker Transformer: One (1) 500 VA Over Current Protection: Circuit Breaker Primary: 480/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 x 12.125 x 6.000 (PSH500A) 11.330 x 11.400 x 5.000 (PSMN500A) Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Sub-Panel: Plenum Rated Polymetal Sub-Panel (PSMN500A) Housing: NEMA1 Metal Enclosure (PSH500A) Weight: 30.16 lbs. (PSH500A) 20.60 lbs. (PSMN500A) 5 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously) Notes: · To order UL508, add "-IC" to end of model number. · Open style (PSMN500A) is mounted to sub-panel SP3303 for shipping. Sub-panel may be removed to suit application. · Primary voltage terminal cover available. See model APS53-TC on page 141. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/OSP-0201-10.pdf Standby Wattage: 48.515 W @ 120 Vac 48.699 W @ 240 Vac 49.564 W @ 277 Vac 48.255 W @ 480 Vac Full Load Primary Current: 4.66 A @ 120 Vac 2.41 A @ 240 Vac 2.06 A @ 277 Vac 1.17 A @ 480 Vac Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp · With 240 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature GREAT FOR VAV APPLICATIONS 116 Functional Devices, Inc. | American Made. American Owned. User Connections POWER SUPPLIES AC POWER SUPPLY PSH300A Enclosed 300VA Power Supply with Three 100VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac PSMN300A Open Style 300VA Power Supply with Three 100VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac 480 277 240 120 COM ON 1 OFF ON OFF 2 ON OFF 3 24V COM 24V COM 24V COM PSH300A Shown With Cover PSH300A Shown Without Cover Switch Indicator Breaker PSMN300A Class 2 Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Transformer: One (1) 300 VA Over Current Protection: Circuit Breaker Primary: 480/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 x 12.125 x 6.000 (PSH300A) 11.330 x 11.400 x 4.500 (PSMN300A) Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508, C-UL, CE, RoHS, Special ^ Seismic Certification of Equipment and Components: OSP-0201-10 Sub-Panel: Plenum Rated Polymetal Sub-Panel (PSMN300A) Housing: NEMA1 Metal Enclosure (PSH300A) Weight: 20.00 lbs. (PSH300A) 11.00 lbs. (PSMN300A) 3 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 3 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 3 Outputs Operated Simultaneously) Notes: · To order UL508, add "-IC" to end of model number. · Open style (PSMN300A) is mounted to sub-panel SP3303 for shipping. Sub-panel may be removed to suit application. · Primary voltage terminal cover available. See model APS53-TC on page 141. · Design is in accordance with ASCE 7-05 Chapter 13: ^ www.oshpd.ca.gov/FDD/Pre-Approval/OSP-0201-10.pdf Standby Wattage: 16.61 W @ 120 Vac 17.70 W @ 240 Vac 16.26 W @ 277 Vac 19.20 W @ 480 Vac Full Load Primary Current: 2.66 A @ 120 Vac 1.36 A @ 240 Vac 1.18 A @ 277 Vac 0.68 A @ 480 Vac Secondary Output Voltage vs. Load: 24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp · With 120 Vac primary input voltage · When all 3 outputs operated simultaneously, at room temperature GREAT FOR VAV APPLICATIONS (800) 888-5538 | www.functionaldevices.com 117 POWER SUPPLIES User Connections AC POWER SUPPLY PSH200A Enclosed 200VA Power Supply with Five 40VA Class 2 Outputs, 480/347/277/240/120 Vac to 24 Vac PSMN200A Open Style 200VA Power Supply with Five 40VA Class 2 Outputs, 480/347/277/240/120 Vac to 24 Vac 347 480 277 240 120 COM ON 1 OFF ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5 24V COM 24V COM 24V COM 24V COM 24V COM PSH200A Shown With Cover PSH200A Shown Without Cover Switch PSMN200A Indicator Breaker SPECIFICATIONS Transformer: One (1) 200 VA Over Current Protection: Circuit Breaker Primary: 480/347/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 x 12.125 x 6.000 (PSH200A) 11.330 x 11.400 x 5.000 (PSMN200A) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Sub-Panel: Plenum Rated Polymetal Sub-Panel (PSMN200A) Housing: NEMA1 Metal Enclosure (PSH200A) Weight: 18.60 lbs. (PSH200A) 8.00 lbs. (PSMN200A) 5 Secondaries: 24 Vac, with LED Indicators 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/347/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 40 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire. Ambient Temperature Derating: 1.6A up to 40° C ; 1.2A up to 60° C (When All 5 Outputs Operated Simultaneously) Notes: · Open style (PSMN200A) is mounted to sub-panel SP3303 for shipping. Sub-panel may be removed to suit application. · Primary voltage terminal cover available. See model APS53-TC on page 141. Class 2 Made in USA Meets "Buy American" of ARRA 2009 Standby Wattage: 18.93 W @ 120 Vac 22.08 W @ 240 Vac 22.33 W @ 277 Vac 23.11 W @ 347 Vac 25.24 W @ 480 Vac Full Load Primary Current: 2.57 A @ 120 Vac 1.44 A @ 240 Vac 1.17 A @ 277 Vac 0.95 A @ 347 Vac 0.73 A @ 480 Vac Secondary Output Voltage vs. Load: 24.9 V @ 0.5 Amp 24.0 V @ 1.0 Amp 23.9 V @ 1.4 Amp 23.7 V @ 1.6 Amp · With 120 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature 347 VAC INPUT VOLTAGE PROVIDES DIRECT CONVERSION FROM MANY CANADIAN SYSTEMS TO CLASS 2 OUTPUTS PERFECT FOR ISOLATING UP TO FIVE ZONE CONTROLLERS 118 Functional Devices, Inc. | American Made. American Owned. User Connections POWER SUPPLIES AC POWER SUPPLY PSH500A-LVC Enclosed 500VA Power Supply, High/Low Voltage Separation with Five 100VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac 480 277 240 120 COM PSH500A-LVC Shown Without High Voltage Cover & Low Voltage Access Plate SPECIFICATIONS Transformer: One (1) 500 VA Over Current Protection: Circuit Breaker Primary: 480/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 x 12.125 x 6.000 Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Housing: NEMA1 Metal Enclosure with high/low separation Weight: 32.30 lbs. ON 1 OFF ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5 24V COM 24V COM 24V COM 24V COM 24V COM Switch Indicator Breaker PSH500A-LVC Shown Without Low Voltage Access Plate PSH500A-LVC Shown With Full Cover & Access Plate 5 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 100 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously) Class 2 Made in USA Meets "Buy American" of ARRA 2009 Standby Wattage: 48.515 W @ 120 Vac 48.699 W @ 240 Vac 49.564 W @ 277 Vac 48.255 W @ 480 Vac Full Load Primary Current: 4.66 A @ 120 Vac 2.41 A @ 240 Vac 2.06 A @ 277 Vac 1.17 A @ 480 Vac Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp · With 240 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature (800) 888-5538 | www.functionaldevices.com 119 AC POWER SUPPLY PSH300A-LVC Enclosed 300VA Power Supply with Three 100VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac 480 277 240 120 COM ON 1 OFF ON OFF 2 ON OFF 3 24V COM 24V COM 24V COM User Connections PSH300A-LVC Shown Without High Voltage Cover & Low Voltage Access Plate Class 2 Made in USA Meets "Buy American" of ARRA 2009 POWER SUPPLIES Switch Indicator Breaker SPECIFICATIONS Transformer: One (1) 300 VA Over Current Protection: Circuit Breaker Primary: 480/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 x 12.125 x 6.000 Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Housing: NEMA1 Metal Enclosure Weight: 22.46 lbs. AC POWER SUPPLY PSH300A-LVC Shown Without Low Voltage Access Plate PSH300A-LVC Shown With Full Cover & Access Plate 3 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 3 Ungrounded, Isolated, 100 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 3 Outputs Operated Simultaneously) Standby Wattage: 16.61 W @ 120 Vac 17.70 W @ 240 Vac 16.26 W @ 277 Vac 19.20 W @ 480 Vac Full Load Primary Current: 2.66 A @ 120 Vac 1.36 A @ 240 Vac 1.18 A @ 277 Vac 0.68 A @ 480 Vac Secondary Output Voltage vs. Load: 24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp · With 120 Vac primary input voltage · When all 3 outputs operated simultaneously, at room temperature PSH200A-LVC Enclosed 200VA Power Supply with Five 40VA Class 2 Outputs, 480/347/277/240/120 Vac to 24 Vac 347 480 277 240 120 COM ON 1 OFF ON OFF 2 ON OFF 3 ON OFF 4 ON OFF 5 24V COM 24V COM 24V COM 24V COM 24V COM User Connections PSH200A-LVC Shown Without High Voltage Cover & Low Voltage Access Plate Class 2 Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Switch Indicator Breaker PSH200A-LVC Shown Without Low Voltage Access Plate Transformer: One (1) 200 VA 5 Secondaries: Standby Wattage: Over Current Protection: Circuit Breaker 24 Vac, with LED Indicators 18.93 W @ 120 Vac Primary: 480/347/277/240/120 Vac Frequency: 50/60 Hz Dimensions: 12.125 x 12.125 x 6.000 Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Housing: NEMA1 Metal Enclosure 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/347/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG 22.08 W @ 240 Vac 22.33 W @ 277 Vac 23.11 W @ 347 Vac 25.24 W @ 480 Vac Full Load Primary Weight: 20.30 lbs. Output: 5 Ungrounded, Isolated, 40 VA, Class 2, 24 Vac Outputs. Terminals accept 12-26 AWG wire. Ambient Temperature Derating: 1.6A up to 40° C ; 1.2A up to 60° C (When All 5 Outputs Operated Simultaneously) Current: 2.57 A @ 120 Vac 1.44 A @ 240 Vac 1.17 A @ 277 Vac 0.95 A @ 347 Vac 0.73 A @ 480 Vac 120 Functional Devices, Inc. | American Made. American Owned. PSH200A-LVC Shown With Full Cover & Access Plate Secondary Output Voltage vs. Load: 24.9 V @ 0.5 Amp 24.0 V @ 1.0 Amp 23.9 V @ 1.4 Amp 23.7 V @ 1.6 Amp · With 120 Vac primary input voltage · When all 5 outputs operated simultaneously, at room temperature POWER SUPPLIES AC POWER SUPPLY PSH500AB10-LVC Enclosed 500VA Power Supply, High/Low Voltage Separation with Five 100VA Class 2 Outputs, 120 Vac to 24 Vac with 120 Vac Receptacle Hot Neut GND 10 Amp Breaker/Switch 4 Amp Breaker 120 Vac Neutral 120 Vac Receptacle Chassis Ground Switch 4 Amp Breaker Switch 4 Amp Breaker Switch 4 Amp Breaker Switch 4 Amp Breaker Switch 4 Amp Breaker LED Indicator LED Indicator LED Indicator LED Indicator LED Indicator PSH500AB10-LVC Shown With High Voltage Cover & Low Voltage Access Plate Class 2 SPECIFICATIONS Transformer: One (1) 500 VA Over Current Protection: Circuit Breaker Primary: 120 Vac Frequency: 50/60 Hz Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: 1 Outlet & Transformer) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 12.125 x 12.125 x 6.000 Housing: NEMA1 Metal Enclosure with high/low separation Weight: 32.30 lbs. 5 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 100 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously) Standby Wattage: 48.515 W @ 120 Vac Full Load Primary Current: 4.66 A @ 120 Vac Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp · When all 5 outputs operated simultaneously, at room temperature Notes: · 4A (Breaker protected) Convenience Receptacle Provided (800) 888-5538 | www.functionaldevices.com 121 AC POWER SUPPLY PSH300AB10-LVC Enclosed 300VA Power Supply, High/Low Voltage Separation with Three 100VA Class 2 Outputs, 120 Vac to 24 Vac with 120 Vac Receptacle Hot Neut GND 10 Amp Breaker/Switch 4 Amp Breaker 120 Vac Neutral 120 Vac Receptacle Chassis Ground Switch 4 Amp Breaker Switch 4 Amp Breaker Switch 4 Amp Breaker LED Indicator LED Indicator LED Indicator PSH300AB10-LVC Shown With High Voltage Cover & Low Voltage Access Plate Class 2 SPECIFICATIONS Transformer: One (1) 300 VA Over Current Protection: Circuit Breaker Primary: 120 Vac Frequency: 50/60 Hz Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: 1 Outlet & Transformer) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 12.125 x 12.125 x 6.000 Housing: NEMA1 Metal Enclosure with high/low separation Weight: 22.12 lbs. 3 Secondaries: 24 Vac, with LED Indicators 4 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 120 Vac Finger-Safe Terminals, 8-18 AWG Output: 3 Ungrounded, Isolated, 100 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire. Ambient Temperature Derating: 4A up to 40° C ; 3A up to 50° C ; 2A up to 55° C (When All 5 Outputs Operated Simultaneously) Standby Wattage: 16.61 W @ 120 Vac Full Load Primary Current: 2.66 A @ 120 Vac Secondary Output Voltage vs. Load: 24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp · When all 5 outputs operated simultaneously, at room temperature Notes: · 4A (Breaker protected) Convenience Receptacle Provided POWER SUPPLIES 122 Functional Devices, Inc. | American Made. American Owned. POWER SUPPLIES AC POWER SUPPLY PSH200AB10-LVC Enclosed 200VA Power Supply, High/Low Voltage Separation with Five 40VA Class 2 Outputs, 120 Vac to 24 Vac with 120 Vac Receptacle Class 2 Hot Neut GND 10 Amp Breaker/Switch 4 Amp Breaker 120 Vac Neutral 120 Vac Receptacle Chassis Ground Switch 2 Amp Breaker Switch 2 Amp Breaker Switch 2 Amp Breaker Switch 2 Amp Breaker Switch 2 Amp Breaker LED Indicator LED Indicator LED Indicator LED Indicator LED Indicator PSH200AB10-LVC Shown With High Voltage Cover & Low Voltage Access Plate SPECIFICATIONS Transformer: One (1) 200 VA Over Current Protection: Circuit Breaker Primary: 120 Vac Frequency: 50/60 Hz Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: 1 Outlet & Transformer) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Dimensions: 12.125 x 12.125 x 6.000 Housing: NEMA1 Metal Enclosure with high/low separation Weight: 20.30 lbs. 5 Secondaries: 24 Vac, with LED Indicators 2 Amp breaker for each output 24 Vac ON/OFF: On / Off Switch & Breaker Input: 120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Ungrounded, Isolated, 40 VA Class 2, 24 Vac Outputs. Removable Terminals accept16-22 AWG wire. Ambient Temperature Derating: 1.6A up to 40° C ; 1.2A up to 60° C (When All 5 Outputs Operated Simultaneously) Standby Wattage: 18.93 W @ 120 Vac Full Load Primary Current: 2.57 A @ 120 Vac Secondary Output Voltage vs. Load: 24.9 V @ 0.5 Amp 24.0 V @ 1.0 Amp 23.9 V @ 1.4 Amp 23.7 V @ 1.6 Amp · When all 5 outputs operated simultaneously, at room temperature Notes: · 4A (Breaker protected) Convenience Receptacle Provided (800) 888-5538 | www.functionaldevices.com 123 AC POWER SUPPLY: 120 VAC TO 24 VAC PSB40AB10 Panel Mount 40 VA Power Supply, 120 to 24 Vac PSB100AB10 Panel Mount 100 VA Power Supply, 120 to 24 Vac Class 2 120 Vac Convenience Outlet * Neutral 120 Vac Ground 120 Vac Aux. Output 2.250" 2.250" 3.750" ON RESET OFF OFF LED Indicator Com 24 Vac 10 Amp Main Breaker/Switch 24 Vac Breaker 24 Vac On/O Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 4.610" ON RESET OFF OFF 5.250" 5.200" SPECIFICATIONS Transformer: One 40 VA Split-Bobbin (PSB40AB10) One 100 VA Split-Bobbin (PSB100AB10) Primary: 120 Vac Secondary: 24 Vac, w/ LED Indicator Frequency: 50/60 Hz Over Current Protection: Inherently Limited + Circuit Breaker (PSB40AB10) Circuit Breaker (PSB100AB10) 24 Vac ON/OFF: On / Off Switch Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit: Outlets, Aux. Output, & Transformer)* Total Combined Output 9A Made in USA Meets "Buy American" of ARRA 2009 REMOVABLE TERMINAL COVER PROVIDED Mounting: Panel mount Temperature: 40° C Approvals: Class 2 (UL Approved UL5085-3), UL916, UL508 for -IC models, C-UL, CE, RoHS Dimensions: 5.200 x 5.250 x 3.750 Weight: 2.18 lbs. (PSB40AB10) 3.58 lbs. (PSB100AB10) Notes: · To order UL508, add "-IC" to end of model number. AC POWER SUPPLY: 120 VAC TO 24 VAC PSMN40AS 2.75 Track Mount 40 VA Power Supply, 120 Vac to 24 Vac, with Switch PSMN40A 2.75 Track Mount 40 VA Power Supply, 120 Vac to 24 Vac LOAD 24 Vac LOAD 24 Vac Class 2 POWER SUPPLIES LINE 120 Vac Switch: On / O LINE 120 Vac SPECIFICATIONS Transformers: One 40 VA Primary: 120 Vac Secondary: 24 Vac, isolated Frequency: 50/60 Hz Overload Protection: Inherently limited Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Secondary Voltage Present Dimensions: 2.500 x 2.750 x 4.000 (without track) 2.800 x 2.750 x 4.000 (in track) Track Mount: MT212-4 Mounting Track Supplied Weight: 1.60 lbs. ON/OFF Switch: 2 Position (PSMN40AS) Approvals: UL916, C-UL, CE, RoHS 124 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 DC POWER SUPPLY: 24 VAC TO 1.5 - 28 VDC PSP24DA Enclosed Non-Isolated Linear DC Power Supply, 24 Vac to 1.5-28 Vdc Adjustable Output VOLTAGE INPUT 24 Vac Class 2 Wht/Yel Wht/Yel VOLTAGE OUTPUT Factory Set to 24 Vdc Adjustable from 1.5-28 Vdc + Wht/Red Wht/Blu Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Voltage Input: 24 Vac, full-wave rectified Voltage Output: 1.5 - 28 Vdc non-isolated Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Weight: .30 lbs. ON/OFF Switch: None Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Output Current Ratings: 116 mA @ 10 Vdc 125 mA @ 12 Vdc 300 mA @ 24 Vdc Input Current Rating: 550 mA Maximum Percent Ripple: 0.0016%, 24 Vdc @ 300 mA Regulation: Load: 0.04% No Load to Full Load Line: 0.0125 V/V Notes: · Requires a separate ungrounded transformer when used in conjunction with 1/2 wave rectified power supplies, grounded 24 Vac transformers, or when 24 Vac and 24 Vdc are connected in common. DC POWER SUPPLY: 120 VAC TO 24 VDC PSH24DWB10 Enclosed Single Switching DC Power Supply 120 to 24 Vdc @ 2.5 Amp Made in USA Meets "Buy American" of ARRA 2009 POWER SUPPLIES 120 Vac Convenience Outlet * 5.438" 5.150" 4.500" 4.500" RESET RESET 4.250" OFF OFF 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 5.150" SPECIFICATIONS Input Voltage: 120 Vac Frequency: 50/60 Hz DC Output: 24 Vdc @ 2.5 Amp Over Current Protection: Circuit Breaker Main Breaker ON/OFF: Switch / Breaker (10 Amp) (Kills power to entire unit)* Total Combined Output 9A Operating Temperature: 32 to 122°F Dimensions: 4.500 x 5.438 x 4.500 Weight: 2.980 lbs. Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Notes: · This device is not certified for use as a Class 2 power source. (800) 888-5538 | www.functionaldevices.com Output Wires: DC Supply Output WHT/RED: 24 Vdc WHT/BLU: 24 Vdc COM Auxiliary Output BLU: 120 Vac 125 POWER SUPPLIES 4.500" 4.250" AC & DC POWER SUPPLY: 120 VAC TO 24 VAC AND 24 VDC PSH100A24DWB10 Enclosed Power Supply, 100 VA (120 to 24 Vac) and Switching 120 to 24Vdc @ 2.5 Amp 24 Vac On/O Switch 24 Vac Breaker 120 Vac Convenience Outlet * 8.625" 8.250" ON OFF RESET OFF ON OFF RESET OFF LED Indicator 120 Vac Convenience Outlet * 10 Amp Main Breaker/Switch * Move internal jumper to "HOT" position if you wish outlets to always be hot otherwise outlets will be switched by main breaker. 8.250" SPECIFICATIONS Transformer: One 100 VA Split-Bobbin Voltage Input: 120 Vac Frequency: 50/60 Hz Over Current Protection: Circuit Breaker 24 Vac ON/OFF: Switch / Breaker (10 Amp) Main Breaker ON/OFF: (Kills power to entire unit: Outlets, Aux. Output, & Transformer, and 24 Vdc)* Total Combined Output 9A Dimensions: 4.500 x 8.625 x 4.500 Weight: 5.600 lbs. 4.500" Input Wires: Input Power Wires BLK: 120 Vac WHT: Neutral GRN: Ground Notes: · This device is not certified for use as a Class 2 power source. DC POWER SUPPLY: 24 VAC TO 1.5 - 28 VDC PSMN24DA 2.75 Track Mount Non-Isolated Linear DC Power Supply, 24Vac to 1.5-28 Vdc, 300 mA Adjustable Output PSMN24DAS 2.75 Track Mount Non-Isolated Linear DC Power Supply, 24Vac to 1.5-28 Vdc, 300 mA Adjustable Output, with Switch Made in USA Meets "Buy American" of ARRA 2009 Output Wires: DC Supply Output WHT/RED: 24 Vdc WHT/BLU: 24 Vdc COM Auxiliary Output BLU: 120 Vac Transformer Output WHT/YEL: 24 Vac WHT/BLU: 24 Vac COM Class 2 Voltage Input 24 Vac Voltage Output Adjustable 1.5-28Vdc + Toggle Switch : On / O Voltage Input 24 Vac Voltage Output Adjustable 1.5-28Vdc + Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Voltage Input: 24 Vac, full-wave rectified Voltage Output: 1.5 - 28 Vdc non-isolated Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 1.500 x 2.750 x 1.750 Track Mount: 2.750 MT212-2 Mounting Track Supplied Weight: 0.20 lbs. ON/OFF Switch: None (PSMN24DA) 2 Position Toggle (PSMN24DAS) Approvals: Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Output Current Ratings: 116 mA @ 10 Vdc 125 mA @ 12 Vdc 300 mA @ 24 Vdc Input Current Rating: 550 mA Maximum Percent Ripple: 0.0016%, 24 Vdc @ 300 mA Regulation: Load: 0.04% No Load to Full Load Line: 0.0125 V/V 126 Functional Devices, Inc. | American Made. American Owned. Notes: · Requires a separate ungrounded transformer when used in conjunction with 1/2 wave rectified power supplies, grounded 24 Vac transformers, or when 24 Vac and 24 Vdc are connected in common. · See also supplementary model PSMN40AS DC POWER SUPPLY: 24 VAC TO 1.5 - 14 VDC PSM20A12DAS 4.00 & 2.75 Track Mount Isolated Linear DC Power Supply, 24 Vac to 1.5-14Vdc, 300 mA Adjustable Output Voltage Output Adjustable From 1.5-14 Vdc + Voltage Input 24 Vac Switch: On / O SPECIFICATIONS Voltage Input: 24 Vac Voltage Output: 1.5 - 14 Vdc Isolated Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 1.625 x 2.750 x 4.000 Track Mount: 4.000 and 2.750 MT212-4 Mounting Track Supplied Weight: 1.10 lbs. ON/OFF Switch: 2 Position Approvals: UL916, C-UL, CE, RoHS Output Current Ratings: 300 mA @ 12 Vdc Input Current Rating: 950 mA Maximum Class 2 Made in USA Meets "Buy American" of ARRA 2009 Percent Ripple: 0.0016%, 12 Vdc @ 300 mA Regulation: Load: 0.04% No Load to Full Load Line: 0.0080 mV/V POWER SUPPLIES DC POWER SUPPLY: 120 VAC OR 24 VAC TO 1.5 - 28 VDC PSM24A24DAS 4.00 & 2.75 Track Mount Isolated Linear DC Power Supply, 24 Vac to 1.5-28 Vdc, 300 mA Adjustable Output PSM19A24DAS 4.00 & 2.75 Track Mount Isolated Linear DC Power Supply, 120 Vac to 1.5-28 Vdc, 300 mA Adjustable Output Voltage Output Adjustable From 1.5-28 Vdc + Voltage Input 24 Vac Switch: On / O Voltage Output Adjustable From 1.5-28 Vdc + Voltage Input 120 Vac Switch: On / O Class 2 Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Voltage Input: 24 Vac (PSM24A24DAS) 120 Vac (PSM19A24DAS) Voltage Output: 1.5 - 28 Vdc Isolated Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 1.625 x 2.750 x 4.000 Track Mount: 4.000 and 2.750 MT212-4 Mounting Track Supplied Weight: 1.10 lbs. ON/OFF Switch: 2 Position Approvals: UL916, C-UL, CE, RoHS Output Current Ratings: 116 mA @ 10 Vdc 125 mA @ 12 Vdc 300 mA @ 24 Vdc Input Current Rating: 950 mA Maximum (PSM24A24DAS) 150 mA Maximum (PSM19A24DAS) Percent Ripple: 0.0016%, 24 Vdc @ 300 mA Regulation: Load: 0.04% No Load to Full Load Line: 0.0080 mV/V (PSM24A24DAS) Line: 0.6250 mV/V (PSM19A24DAS) (800) 888-5538 | www.functionaldevices.com 127 DC POWER SUPPLY: 120 VAC TO 24 VDC PSMN40A24DS 2.75 Track Mount Isolated Linear DC Power Supply, 120 Vac to 24 Vdc, 1 Amp + Voltage Output 24 Vdc Voltage Input 120 Vac Switch: On / O SPECIFICATIONS Voltage Input: 120 Vac Voltage Output: 24 Vdc Isolated Frequency: 50/60 Hz Overload Protection: Electrical and Thermal, Auto-Reset Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: LED On = Activated Dimensions: 2.500 x 2.750 x 5.000 (without track) 2.800" x 2.750" x 5.000" (in track) Track Mount: 2.750 MT212-6 Mounting Track Supplied Weight: 1.50 lbs. ON/OFF Switch: 2 Position Approvals: UL916, C-UL, CE, RoHS Output Current Ratings: 1 A @ 24 Vdc Input Current Rating: 400 mA Maximum Class 2 Made in USA Meets "Buy American" of ARRA 2009 Percent Ripple: 0.0016%, 24 Vdc @ 1 A Regulation: Load: 0.50% No Load to Full Load Line: 25.0000 mV/V POWER SUPPLIES 128 Functional Devices, Inc. | American Made. American Owned. TRANSFORMERS 20 VA - 375 VA Style 1 Single Hub & Foot Mount Style 2 Single Hub & Foot Mount with Circuit Breaker Style 3 Single Hub & Foot Mount with Circuit Breaker Style 4 Dual Hub & Foot Mount Style 5 Dual Hub & Foot Mount with Circuit Breaker Style 6 Single Hub & Side Opening with Circuit Breaker Style 7 Two Bottom Openings & Foot Mount Style 8 Single Hub, Side Opening & Foot Mount · Transformers may be foot mount, hub mount, or both. Transformers with the hub mount option will have either a single threaded hub or dual threaded hubs. Several transformers are provided with a circuit breaker and many are Class 2. Pigtail wires are standard on most models and are typically 8.00 in length 1. All transformers utilize split-bobbin construction, making them inherently isolated. Custom transformers are also available (contact factory). Frequency: 50/60 Hz Hub Style: .5 NPT Hub Wire Length: 8 Typical with .5 Strip 1 Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) MTBF: 100,000 Hours @ 77° F Construction: Split-Bobbin Approvals: CE approved, RoHS. See chart for UL approvals. 1 = · TR40VA022 = 8 Primary, 30 Secondary, with .5 Strip · TR50VA019 = 28 Typical with .5 Strip · TR100VA002-20 = 8 Primary, 20 Secondary, with .5 Strip · Instructions inside product box include wire colors/voltages. · Additional information on voltage and wire colors is available in individual data sheets on website. http://www.functionaldevices.com/building-automation/transformers.php Or scan QR code with your smart phone. TRANSFORMERS Style 9 Single Hub & Dual Terminal Secondary Style 11 Two Side Openings & Foot Mount Style 13 90º Conduit Connector & Mounting Plate Opening Style 10 Two End-Bell Openings, & Foot Mount with Circuit Breaker DIMENSIONS: SEE CHART. C Style 12 A Dual Hub & Foot Mount with Circuit Breaker L 1 .50" 8.00" D (800) 888-5538 | www.functionaldevices.com B 1 8.00" .50" W H 129 TRANSFORMERS 40 VA - 100 VA | US Manufactured Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). US Manufactured Control Transformers · 40 VA through 100 VA · Single and dual hub · Foot or hub mountable · Circuit breaker models · Class 2 UL Listed · 24 Vac secondary · Single and multi-tap primaries · Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). ARRA Certificates available upon request. MaddeeiinnUUSSAA Meets "Buy American" of ARRA 2009 TRANSFORMERS US MANUFACTURED TRANSFORMERS MODEL # TR40VA001US MADE IN USA1 OVER VA CURRENT CLASS RATING STYLE PROTECTION 2 · · 40VA 1 Inherent · PRIMARY VOLTAGE (VAC) 120 SEC. VOLTAGE (VAC) 24 FOOT MOUNT · HUBS 1 Threaded L W H A B 2.380" 2.200" 2.930" 1.720" 1.750" C .980" WEIGHT 1.80 lbs. TR40VA002US · · 40VA 4 Inherent · 120 24 · 2 Threaded 2.380 2.200 2.920 1.720 1.750 .980" 1.80 lbs. TR50VA001US · · 50VA 1 Fuse · 120 24 · 1 Threaded 2.750" 2.200" 2.910" 2.060" 1.750" 1.330" 2.20 lbs. TR50VA005US · · 50VA 2 Circuit Brkr. · 120 24 · 1 Threaded 3.270 2.525 3.250 2.210 2.000 1.130 2.60 lbs. · TR50VA022US NEW · 50VA 5 Circuit Brkr. · 480/277/240/208/120 24 · 2 Threaded 3.260 2.525 3.290 2.190 2.000 1.120 2.65 lbs. TR100VA001US · · 96VA 2 Circuit Brkr. · 120 24 · 1 Threaded 3.780 2.500 3.290 2.740 2.000 1.630 3.40 lbs. TR100VA002US · · 96VA 5 Circuit Brkr. · 120 24 · 2 Threaded 3.750 2.500 3.290 2.690 2.000 1.600 3.40 lbs. · TR100VA009US NEW · 96VA 5 Circuit Brkr. · 480/277/240/208/120 24 · 2 Threaded 3.500 2.500 3.250 2.720 2.000 1.630 3.60 lbs. 1 = Made in USA. Meets "Buy American" of ARRA 2009 FOR MORE TRANSFORMERS, SEE NEXT PAGE. 130 Functional Devices, Inc. | American Made. American Owned. TRANSFORMERS TRANSFORMERS MODEL # TR20VA001 TR20VA002 TR20VA003 TR20VA004 TR20VA007 TR40VA001 TR40VA002 TR40VA003 TR40VA004 TR40VA013 TR40VA015 TR40VA022 # TR40VA040 ^ TR50VA001 TR50VA002 TR50VA003 TR50VA004 TR50VA005 TR50VA006 TR50VA007 TR50VA008 TR50VA009 TR50VA014 TR50VA015 TR50VA016 TR50VA017 OVER VA CURRENT CLASS RATING STYLE PROTECTION 2 · 20VA 1 Inherent · PRIMARY VOLTAGE (VAC) 120 SEC. VOLTAGE FOOT (VAC) MOUNT 24 · · 20VA 4 Inherent · 208 24 · · 20VA 1 Inherent 24 24 · · 20VA 4 Inherent · 277/240/208/120 24 · · 20VA 1 Inherent · 277 24 · · 40VA 1 Inherent · 120 24 · · 40VA 4 Inherent · 120 24 · · 40VA 1 Inherent 24 24 · · 40VA 4 Inherent · 277/240/208/120 24 · · 40VA 2 Circuit Brkr. 480/277/240/208 120 · · · 40VA 1 Internal Thermal 240/208/120 24 · · 40VA 4 Inherent · 120 24 · · · 40VA 9 Internal Thermal 240/208/120 24 · · 50VA 1 Fuse · 120 24 · · 50VA 4 Fuse · 120 24 · · 50VA 4 Fuse · 240/208 24 · · 50VA 5 Circuit Brkr. · 480/277/240/120 24 · · 50VA 2 Circuit Brkr. · 120 24 · · 50VA 1 Fuse · 277 24 · · 50VA 4 Fuse · 277 24 · · 50VA 5 Circuit Brkr. 480/277/240/208 120 · · 50VA 5 Circuit Brkr. · 240/208/120 24 · · 50VA 2 Circuit Brkr. · 277 24 · · 50VA 2 Circuit Brkr. · 480/277/240/208/120 24 · · 50VA 2 Circuit Brkr. · 240/208/120 24 · · 50VA 2 Circuit Brkr. · 480/277/208 24 · HUBS 1 Threaded 2 Threaded 1 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 1 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 2 Threaded 2 Threaded 1 Threaded 1 Threaded 2 Threaded 2 Threaded 2 Threaded 1 Threaded 1 Threaded 1 Threaded 1 Threaded L W H A B C D WEIGHT 2.226" 1.877" 2.595" 1.612" 1.619" 1.013" 2.125" 1.20 lbs. 2.296" 1.902" 2.616" 1.604" 1.665" 1.020" 2.114" 1.40 lbs. 2.272" 1.900" 2.628" 1.635" 1.686" 1.023" 2.153" 1.40 lbs. 2.310" 1.890" 2.625" 1.540" 1.625" 1.000" 2.100" 1.40 lbs. 2.302" 1.895" 2.607" 1.608" 1.685" 1.019" 2.107" 1.20 lbs. 2.607" 2.169" 2.906" 2.020" 1.786" 1.204" 2.545" 2.00 lbs. 2.634" 2.177" 2.886" 2.007" 1.775" 1.206" 2.564" 2.00 lbs. 2.653" 2.171" 2.882" 2.033" 1.779" 1.185" 2.580" 2.00 lbs. 2.631" 2.177" 2.882" 1.998" 1.774" 1.189" 2.553" 2.20 lbs. 3.267" 2.505" 3.000" 1.699" 1.986" 1.114" 2.325" 2.65 lbs. 2.628" 2.175" 2.907" 2.040" 1.780" 1.188" 2.590" 2.20 lbs. 2.660" 2.172" 2.891" 1.980" 1.786" 1.201" 2.526" 2.00 lbs. 2.728" 2.171" 2.890" 1.995" 1.792" 1.215" 2.550" 2.20 lbs. 2.677" 2.178" 2.879" 2.109" 1.793" 1.253" 2.664" 2.00 lbs. 2.696" 2.181" 2.908" 2.053" 1.788" 1.278" 2.614" 2.00 lbs. 2.695" 2.181" 2.899" 2.082" 1.778" 1.294" 2.646" 2.00 lbs. 3.475" 2.513" 3.014" 1.858" 1.970" 1.291" 2.490" 3.00 lbs. 3.489" 2.515" 3.008" 1.870" 1.971" 1.294" 2.463" 2.40 lbs. 2.763" 2.182" 2.898" 2.135" 1.790" 1.322" 2.698" 2.00 lbs. 2.715" 2.173" 2.886" 2.148" 1.784" 1.276" 2.661" 2.00 lbs. 3.440" 2.510" 3.012" 1.932" 1.945" 1.346" 2.523" 3.04 lbs. 3.412" 2.504" 3.014" 1.864" 1.961" 1.313" 2.485" 2.80 lbs. 3.479" 2.509" 3.009" 1.873" 1.965" 1.285" 2.480" 2.60 lbs. 3.405" 2.517" 3.013" 1.875" 1.985" 1.316" 2.484" 2.80 lbs. 3.345" 2.510" 3.028" 1.842" 1.978" 1.325" 2.454" 2.80 lbs. 3.470" 2.520" 3.031" 1.880" 1.872" 1.292" 2.460" 2.40 lbs. TR50VA018 TR50VA019 # TR75VA001 TR75VA002 TR75VA003 · 50VA 13 50VA 11 · 75VA 2 · 75VA 5 · 75VA 2 Inherent Circuit Brkr. Circuit Brkr. Circuit Brkr. 480/277/240/208 120 · 277/120 24 · 120 24 · 120 24 · 277 24 1, 90° Conduit Connector, 1 Mounting Refer to data sheet on website. 3.00 lbs. Plate Opening · 2 Side Openings 2.470" 2.170" 2.896" 1.850" 1.740" 1.130" 2.512" 2.00 lbs. · 1 Threaded 3.743" 2.506" 3.016" 2.256" 1.974" 1.711" 2.873" 3.40 lbs. · 2 Threaded 3.890" 2.508" 3.013" 2.290" 1.952" 1.701" 2.882" 3.60 lbs. · 1 Threaded 3.875" 2.507" 3.037" 2.269" 1.978" 1.684" 2.860" 3.60 lbs. TR75VA004 · 75VA 6 TR75VA005 · 75VA 2 TR75VA007 · 75VA 5 TR100VA001 · 100VA 2 TR100VA002 · 100VA 5 · TR100VA002-20 # 100VA 5 TR100VA004 · 100VA 5 TR100VA005 · 100VA 2 TR100VA008 · 100VA 5 · TR100VA009 NEW 100VA 5 · TR100VA015 NEW 100VA 2 TR150VA001 · 150VA 3 TR150VA002 · 150VA 5 TR150VA008 · 150VA 12 TR175VA001 · 175VA 7 TR175VA002 · 175VA 4 Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. Circuit Brkr. · 480/240/208/120 24 · 480/240/208/120 24 · 480/240/208/120 24 · 120 24 · 120 24 · 120 24 · 480/277/240/120 24 · 480/277/240/120 24 480/277/240/208 120 · 480/277/240/208/120 24 · 480/277/240/208/120 24 120 24 120 24 480/277/240/208 120 240/208 24 120 24 · 1 Threaded 3.802" 2.515" 3.050" 2.244" 1.990" 1.665" 2.850" 3.60 lbs. 1 Side Opening · 1 Threaded 3.880" 2.515" 3.030" 2.270" 1.975" 1.700" 2.854" 3.80 lbs. · 2 Threaded 3.883" 2.504" 3.034" 2.287" 1.981" 1.708" 2.887" 3.97 lbs. · 1 Threaded 4.085" 2.515" 3.030" 2.486" 1.975" 1.900" 3.082" 3.80 lbs. · 2 Threaded 4.077" 2.504" 3.023" 2.470" 1.975" 1.888" 3.095" 4.00 lbs. · 2 Threaded 3.973" 2.518" 3.033" 2.486" 1.865" 1.924" 3.060" 4.00 lbs. · 2 Threaded 4.173" 2.523" 3.041" 2.647" 1.976" 2.086" 3.268" 4.40 lbs. · 1 Threaded 4.258" 2.510" 3.030" 2.670" 1.968" 2.065" 3.260" 4.40 lbs. · 2 Threaded 4.220" 2.525" 3.022" 2.690" 1.970" 2.082" 3.272" 4.40 lbs. · 2 Threaded 4.270" 2.500" 3.060" 2.750" 1.975" 2.000" 2.252" 4.40 lbs. · 1 Threaded 4.270" 2.500" 3.060" 2.699" 2.030" 2.065" 2.252" 4.74 lbs. · 1 Threaded 3.650" 3.800" 3.183" 2.560" 3.150" 1.438" 3.514" 5.00 lbs. · 2 Threaded 3.620" 3.785" 3.160" 2.568" 3.147" 1.456" 3.511" 5.00 lbs. · 2 Threaded 4.283" 3.786" 3.161" 3.211" 3.260" 2.116" 4.177" 7.20 lbs. · 2 Bottom Openings 3.801" 3.790" 3.163" 3.264" 3.141" 2.151" 4.197" 7.00 lbs. · 2 Threaded 3.800" 3.790" 3.189" 3.220" 3.150" 2.100" 4.180" 7.10 lbs. TR175VA003 · 175VA 1 Thermal Fuse on Primary 120 24 · 1 Threaded 4.030" 3.786" 3.161" 3.189" 3.155" 2.127" 4.153" 7.44 lbs. TR240VA001 TR300VA002 TR375VA001 · 240VA 8 300VA 10 · 375VA 7 Circuit Brkr. 120 24 480/240/208/120 24 120 24 · 1 Threaded 3.957" 3.750" 4.530" 3.350" 3.180" 1.932" 4.025" 8.60 lbs. 1 Bottom Opening · 2 End-Bell Openings 5.499" 3.750" 4.500" 3.859" 3.187" 2.526" 4.526" 11.60 lbs. · 2 Bottom Openings 4.592" 3.747" 4.504" 3.933" 3.181" 2.516" 4.630" 11.20 lbs. = UL Listed : UL5085-2 or UL5085-3 ; USA & Canada = UL Component Recognized : UL5085-2 or UL5085-3 ; USA & Canada # = Refer to website for more wire length information. ^ = Dual Terminal Secondary (800) 888-5538 | www.functionaldevices.com 131 Notes TRANSFORMERS 132 Functional Devices, Inc. | American Made. American Owned. POWER CONTROL Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Enclosed Power Control Centers · Two 120 Vac grounded convenience outlets · 4 or 10 Amp switch / circuit breaker · Outlets can be continuously powered or controlled by the switch / circuit breaker · True override switch on load side of relay · Auxiliary outputs are provided for convenient control panel installations Track Mount Circuit Breaker Switches · Track mount circuit breaker switches provide a convenient addition to control panels · Circuits can be low voltage (24 Vac) or line voltage (120 Vac) Prepackaged Switches · Standard configurations to provide simple switching schemes · Labels can be ordered with custom content to fit your project UPS Interface · Functional Devices provides a 550 VA commercial UPS along with an enclosure and an interface board, which allows the installer to hardwire line voltage to the provided UPS while giving the ability to hardwire the UPS to the final load. POWER CONTROL ENCLOSED POWER CONTROL CENTERS MODEL # PSPT2RB4 PSPW2RB4 PSPT2RB10 PSPW2RB10 CONVENIENCE OUTLETS · 2, 120 Vac · 2, 120 Vac · 2, 120 Vac · 2, 120 Vac SWITCH On / Off On / Off On / Off On / Off CIRCUIT BREAKER 4 Amp 4 Amp 10 Amp 10 Amp NOTES SPEC PAGE 134 134 134 134 TRACK MOUNT CIRCUIT BREAKER SWITCHES MODEL # PSMN01SB4 · PSMN01SB10 · PSMN24SB4 · PSMN24SB10 · POWER INPUT 120 Vac 120 Vac 24 Vac 24 Vac SWITCH LED On / Off · On / Off · On / Off · On / Off · CIRCUIT BREAKER 4 Amp 10 Amp 4 Amp 10 Amp NOTES SPEC PAGE 134 134 134 134 PREPACKAGED SWITCHES MODEL # PSMS1 SIB02S SIB04S SIB05S SIBLS ENCLOSED TRACK MOUNT CONVENIENCE OUTLETS SWITCH CIRCUIT BREAKER · · 5 A, Maintained 3 Position · · 20 A, Maintained 3 Position · · 20 A, Maintained 2 Position (On / On) · · 20 A, Maintained 2 Position (On / Off ) · · 5 A, Maintained 3 Position NOTES SPEC PAGE 135 135 135 135 135 UPS INTERFACE MODEL # ENCLOSURE RELAY OUTPUT (STATUS) UPS PSH550-UPS (Kit) · · PSH2RB10 · · PSM2RB10 · PSH550-UPS-STAT (Kit) · 2 · PSH2C2RB10 · · 2 PSMN2C2RB10 · 2 PSH850-UPS-STAT (Kit) · 2 · PSH2C2RB10-L · · 2 = UL Listed : UL916 Energy Management; UL Listed Canada CIRCUIT BREAKER · · · · · · · · 120 OUTLET · · · · · · · · (800) 888-5538 | www.functionaldevices.com NOTES SPEC PAGE 136 136 137 137 138 138 139 139 133 SWITCH / CIRCUIT BREAKER COMBOS PSPT2RB4 Enclosed Power Control Center, 4 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Terminals Outlets will always be energized when jumper is in this position. INPUT Outlets will be controlled by switch/breaker when jumper is in this position. OUTPUT PSPT2RB10 Enclosed Power Control Center, 10 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Terminals Outlets will always be energized when jumper is in this position. INPUT Outlets will be controlled by switch/breaker when jumper is in this position. OUTPUT ALWAYS HOT SWITCHED ALWAYS HOT SWITCHED G N H H N G G N H H N G GND "G" and Neutral "N" pass from INPUT to OUTPUT uninterrupted. Output Hot "H" is controlled by switch/breaker. PSPW2RB4 Enclosed Power Control Center, 4 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Wires Outlets will always be energized when jumper is in this position. INPUT G N H Outlets will be controlled by switch/breaker when jumper is in this position. OUTPUT H N G GND "G" and Neutral "N" pass from INPUT to OUTPUT uninterrupted. Output Hot "H" is controlled by switch/breaker. PSPW2RB10 Enclosed Power Control Center, 10 Amp Switch / Circuit Breaker, 120 Vac, 2 Outlets, Wires Outlets will always be energized when jumper is in this position. INPUT G N H Outlets will be controlled by switch/breaker when jumper is in this position. OUTPUT H N G SWITCHED Green Wire White Wire Black Wire ALWAYS HOT SWITCHED Green Wire White Wire Black Wire ALWAYS HOT Blue Wire Blue Wire BLUE = LOAD Blue wire is controlled by switch/breaker. BLUE = LOAD Blue wire is controlled by switch/breaker. PSP SERIES Model # PSPT2RB4 PSPT2RB10 PSPW2RB4 PSPW2RB10 Circuit Breaker 4 Amps 10 Amps 4 Amps 10 Amps Terminals · · Wires · · Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Circuit Breaker: 4 Amp Max. or 10 Amp Max. Dimensions: 4.000 x 4.000 x 1.800 (w/ .500 NPT Nipple - PSPW2RB4 & PSPW2RB10) Wires: 16, 600V Rated (PSPW2RB4 & PSPW2RB10) Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Terminals: Ground "G and Neutral "N pass from INPUT to OUTPUT uninterrupted. OUTPUT (PSPT2RB4 & PSPT2RB10) Hot "H is controlled by the switch/breaker. Notes: · Indicator light will illuminate when switch/breaker is ON (RESET position) indicating power has been transferred from INPUT to OUTPUT by the switch/breaker. If it is desired for the indicator light to be illuminated continuously to indicate the presence of input (Line) power, INPUT and OUTPUT may be reversed -- connect input power from line to OUTPUT and connect output load to INPUT (operation of the jumpers above also reverses). POWER CONTROL Correction Factor Correction Factor PREPACKAGED CIRCUIT BREAKER SWITCHES PSMN01S SERIES 2.75 Track Mount Switch, 2 Position Maintained, On/Off, Circuit Breaker, 120 Vac Temperature Compensation 1.40 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 -20 -10 0 10 20 30 40 50 60 Ambient Temperature in Degrees Centigrade (ºC) PSMN24S SERIES 2.75 Track Mount Switch, 2 Position Maintained, On/Off, Circuit Breaker, 24 Vac Temperature Compensation 1.40 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 -20 -10 0 10 20 30 40 50 60 Ambient Temperature in Degrees Centigrade (ºC) OVER CURRENT / SHORT CIRCUIT PROTECTION AND SWITCHING Blk 120 Vac Wht ON OFF PSMN01S Series Load Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Circuit Breaker: 4 Amp and 10 Amp Dimensions: 2.750 x 1.350 x 2.061 Track Mount: MT212-2 Mounting Track Provided Approvals: UL Listed, UL916, C-UL PSMN01S SERIES Model # PSMN01SB4 PSMN01SB10 Circuit Breaker 4 Amps 10 Amps Ex: TR50VA002 Blk 120 Vac Wht 134 Yel/Wht Yel 24 Vac ON OFF PSMN24S Series PSMN24S SERIES Load Model # PSMN24SB4 PSMN24SB10 Functional Devices, Inc. | American Made. American Owned. Circuit Breaker 4 Amps 10 Amps PREPACKAGED SWITCH PSMS1 4.000 Track Mount Switch 5 Amp, 30 Vac/dc, 3 Position Maintained Power Input Vac/dc (+ if DC) Controller DO Comm (- if DC) CLOSED Green OPEN OUT AUTO Red Yellow Comm (- if DC) SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.275 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Switch Status: Green LED On = Power Input present Yellow LED On = Controller DO ON Red LED On = Output Signal ON Approvals: UL Listed, UL916, C-UL, CE, RoHS Switch Ratings: 5 Amp @ 30 Vac/dc Made in USA Meets "Buy American" of ARRA 2009 PREPACKAGED SWITCHES SIB02S Enclosed Switch 20 Amp, 3 Position Maintained, On/Off/On Blu SIB04S Enclosed Switch 20 Amp, 2 Position Maintained, On/On, 3 Wires Blu CLOSED OPEN Yel AUTO Org CLOSED Yel AUTO Org SIB05S Enclosed Switch 20 Amp, 2 Position Maintained, On/Off, 2 Wires SIBLS Enclosed Switch 5 Amp, 30 Vac/dc, 3 Position Maintained, On/Off/On with LED Indicator Org ON Org OFF Wht/Blu ( + if d/c) CLOSED OPEN AUTO Brn ( + if d/c) Org Wht/Yel ( if d/c) * SIB02S-RD SIB04S-RD SIB05S-RD SIBLS-RD · Red housing Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 1.700 x 2.800 x 1.500 (w/ .500 NPT Nipple) Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 SIB02S, SIB04S, RIB05S Switch Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 10 Amp Tungsten @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac SIBLS Switch Ratings: 5 Amp @ 30 Vac/dc Notes: · Switch position label can be custom printed according to your needs, simply consult factory · Connection to Wht/Yel may be omitted if LED is not needed (SIBLS) * POWER CONTROL (800) 888-5538 | www.functionaldevices.com 135 UNINTERRUPTIBLE POWER SUPPLY KIT PSH550-UPS Kit Consisting of Enclosed Power Control Center Model PSH2RB10 (10 Amp Switch / Circuit Breaker, Two (2) 120 Vac Outlets, Terminals, 120 Vac Input) with a 550 VA UPS. (No Status Contacts) UPS } On/O Switch, Breaker To Protected 120 Vac & Indicator Light Device Line Input } UPS Output Line Input RESET Hot OFF Neut. GND GND Neut. Hot To UPS Computer Outlet Shown Without Cover Shown With Cover Made in USA Meets "Buy American" of ARRA 2009 From UPS To UPS SPECIFICATIONS UPS UPS: 550VA Backup Time: 3 Min. @ Full 550 VA Load 15 Min. @ 1/2 Load Input: 120 Vac, 12 Amp Output: 120 Vac, 4.6 Amp Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Approvals: UL Listed, UL1778 PSH2RB10 Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS Dimensions: 12.000 x 14.000 x 6.000 Metal Housing with Screw Cover Shipping Weight: 28 lbs. Product Weight: 22.5 lbs. Notes: · To order without UPS, so that any other commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2RB10. · To order interface board for replacement or for separate use, order model PSM2RB10. · Average battery life: 3-5 years depending on the number of discharge cycles and environmental temperature Backup Time (Minutes) ESTIMATED BACKUP TIME VS. LOAD 60 50 40 30 20 10 0 0 50 100 150 200 250 300 350 Load (Watts) POWER CONTROL ENCLOSED UPS INTERFACE MODULE PSH2RB10 Enclosed 4.00 Track Mount Power Control Center, 10 Amp Switch / Circuit Breaker, Two (2) 120 Vac Outlets, Terminals, 120 Vac Input. (No Status Contacts) UPS (Not Included) } On/O Switch, Breaker To Protected 120 Vac & Indicator Light Device Line Input } UPS Output Line Input RESET Hot OFF Shown Without Cover Neut. GND GND Neut. Hot From UPS To UPS Computer Outlet To UPS Shown With Cover SPECIFICATIONS Operating Temperature: -30 to 140° F Notes: Humidity Range: 5 to 95% (noncondensing) · Track mounted interface board may be ordered separately as model PSM2RB10, to Main Breaker ON/OFF: Switch / Breaker (10 Amp) be used with any commercial UPS with appropriate ratings for the circuit breaker. Approvals: UL Listed, UL916, C-UL, CE, RoHS · Circuit breaker for short protection. Dimensions: 12.000 x 14.000 x 6.000 · 14/3 Line Cord included (3´). Metal Housing with Screw Cover · Use with UPS devices rated 1000 VA or less. Weight: 13.10 lbs. · Max. size: 12.000 x 7.250 x 5.500 · 120 Vac max., 600 W max., 8.3 Amp max. · UPS is not included. 136 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 UPS INTERFACE MODULE PSM2RB10 4.00 Track Mount Power Control Center, with 10 Amp Switch / Circuit Breaker, Two (2) 120 Vac Outlets, Terminals, 120 Vac Input. (No Status Contacts) UPS (Not Included) } To Protected 120 Vac On/O Switch, Breaker Device Line Input & Indicator Light } UPS Output Line Input RESET Hot OFF Neut. GND GND Neut. Hot To UPS Computer Outlet BUY SEPARATELY AND PLACE IN AN ENCLOSURE OF YOUR CHOICE From UPS To UPS SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 4.000 x 3.250 x 1.750 Track Mount: 3.250 x 4.000 MT4-4N Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS Notes: · Circuit breaker for short protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · UPS is not included. Made in USA Meets "Buy American" of ARRA 2009 POWER CONTROL UNINTERRUPTIBLE POWER SUPPLY IN KIT PSH550-UPS-STAT Kit Consisting of Enclosed Power Control Center Model PSH2C2RB10 (10 Amp Switch / Circuit Breaker, Two (2) 120 Vac Outlets, Terminals, 120 Vac Input) with a 550 VA UPS. (Status Contacts) UPS Status Contacts & 120 Vac LED Indicator Line Input Input Power Status Contacts & LED Indicator } GND } Neut. Line N/C } COM N/O N/C COM N/O UPS GND Neut. Line RESET OFF Shown Without Cover Made in USA Meets "Buy American" of ARRA 2009 Line Neut. GND From UPS Backed Up Outlet } } To Protected Device To UPS UPS plugged into one of two outlets. Other outlet spare. Shown With Cover SPECIFICATIONS Backup Time (Minutes) UPS UPS: 550VA Backup Time: 3 Min. @ Full 550 VA Load 15 Min. @ 1/2 Load Input: 120 Vac, 12 Amp Output: 120 Vac, 4.6 Amp Max Load: 330 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 104° F UPS Transfer Time: 6ms Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc (N/O) 7 Amp @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 1000 VA @ 120 Vac Magnetic Ballast (N/C) C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty ESTIMATED BACKUP TIME VS. LOAD 60 50 40 30 20 Approvals: UL Listed, UL1778 Weight: 12 lbs. Notes: · To order without UPS, so that any other 10 PSH2C2RB10 Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) commercial UPS with appropriate ratings and within housing space limitations may be used, see model PSH2C2RB10. · To order interface board for 0 0 50 100 150 200 250 300 350 Load (Watts) Main Breaker ON/OFF: Switch / Breaker (10 Amp) replacement or for separate use, order Approvals: UL Listed, UL916, C-UL, model PSMN2C2RB10. CE, RoHS · Average battery life: 3-5 years Dimensions: 12.000 x 16.000 x 6.000 depending on the number of discharge Metal Housing with cycles and environmental temperature Screw Cover (800) 888-5538 | www.functionaldevices.com 137 ENCLOSED UPS INTERFACE MODULE PSH2C2RB10 Enclosed 2.75 Track Mount Power Control Center, with 10 Amp Switch / Circuit Breaker, Two (2) 120 Vac Outlets, Terminals, 120 Vac Input. (Status Contacts) UPS Status Contacts & 120 Vac LED Indicator Line Input Input Power Status Contacts & LED Indicator } GND } Neut. Line N/C } COM N/O N/C COM N/O UPS (Not Included) GND Neut. Line RESET OFF Line Neut. GND } } From UPS Backed-Up Outlet To Protected Device To UPS UPS plugged into one of two outlets. Other outlet spare. Shown Without Cover Shown With Cover Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS Dimensions: 12.000 x 16.000 x 6.000 Metal Housing with Screw Cover Weight: 14.14 lbs. Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc N/O 7 Amp @ 30 Vdc N/C 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 100 VA @ 120 Vac Ballast N/C C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty Notes: · Track mounted interface board may be ordered separately as model PSMN2C2RB10, to be used with any commercial UPS with appropriate ratings for the circuit breaker. · Circuit breaker for short-circuit protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · Max. size: 8.000 x 16.000 x 5.500 · 120 Vac max., 600 W max., 8.3 Amp max. · UPS is not included. POWER CONTROL UPS INTERFACE MODULE PSMN2C2RB10 2.75 Track Mount Power Control Center, with 10 Amp Switch / Circuit Breaker, Two (2) 120 Vac Outlets, Terminals, 120 Vac Input. (Status Contacts) UPS Status Contacts & 120 Vac LED Indicator Line Input Input Power Status Contacts & LED Indicator GND } Neut. Line N/C } COM N/O N/C COM N/O UPS (Not Included) GND Neut. Line RESET OFF } Made in USA Meets "Buy American" of ARRA 2009 Line Neut. GND } } From UPS Backed-Up Outlet To Protected Device To UPS UPS plugged into one of two outlets. Other outlet spare. SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Dimensions: 2.750 x 6.655 x 1.750 Track Mount: 2.750 x 6.000 MT212-6N Mounting Track Included Approvals: UL Listed, UL916, C-UL, CE, RoHS BUY SEPARATELY AND PLACE IN AN ENCLOSURE OF YOUR CHOICE Line Input Status Contacts and UPS Output Status Contacts Rated: 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc N/O 7 Amp @ 30 Vdc N/C 1/2 HP @ 125 Vac 1/4 HP @ 277 Vac 100 VA @ 120 Vac Ballast N/C C300 Pilot Duty 16.8 VA @ 24 Vac Pilot Duty Notes: · Circuit breaker for short-circuit protection. · 14/3 Line Cord included (3´). · Use with UPS devices rated 1000 VA or less. · UPS is not included. 138 Functional Devices, Inc. | American Made. American Owned. UNINTERRUPTIBLE POWER SUPPLY IN KIT PSH850-UPS-STAT Kit Consisting of Enclosed Power Control Center Model PSH2C2RB10-L (10 Amp Switch / Circuit Breaker, Two (2) 120 Vac Outlets, Terminals, 120 Vac Input) with a 850 VA UPS. (Status Contacts) UPS Status Contacts & 120 Vac LED Indicator Line Input Input Power Status Contacts & LED Indicator Shown Without Cover } GND } Neut. Line N/C } COM N/O UPS GND Neut. Line RESET OFF Line Neut. GND From UPS Backed Up Outlet } To Protected Device To UPS UPS plugged into one of two outlets. Other outlet spare. } N/C COM N/O SINUSOIDAL OUTPUT OR PURE SINE WAVE OUTPUT Shown With Cover Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS UPS UPS: 850VA Backup Time: 2 Min. @ Full 850 VA Load 8 Min. @ 1/2 Load Input: 120 Vac, 12 Amp Sine Wave Output: 120 Vac, 7.1 Amp Max Load: 510 Watt Frequency: 50/60 Hz Temperature Rating of UPS: 32 to 95° F UPS Transfer Time: 10ms Approvals: UL Listed, UL1778 Weight: 15 lbs. Model: Cyber Power Model 850PFCLCD PSH2C2RB10-L Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Main Breaker ON/OFF: Switch / Breaker (10 Amp) Approvals: UL Listed, UL916, C-UL, CE, RoHS Dimensions: 14.000 x 16.000 x 6.000 Metal Housing with Screw Cover Line Input Status Contacts and UPS Output Status Contacts Rated: ESTIMATED BACKUP TIME VS. LOAD 70 10 Amp @ 277 Vac General Use 10 Amp @ 30 Vdc (N/O) 60 Backup Time (Minutes) 7 Amp @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 50 1/4 HP @ 277 Vac 40 1000 VA @ 120 Vac Magnetic Ballast (N/C) C300 Pilot Duty 30 16.8 VA @ 24 Vac Pilot Duty 20 Notes: · To order without UPS, so that any other 10 commercial UPS with appropriate ratings and within housing space limitations 0 0 may be used, see model PSH2C2RB10-L. · To order interface board for replacement or 100 200 300 400 500 550 Load (Watts) for separate use, order model PSMN2C2RB10. · Typical battery life: 3-6 years, depending on number of discharge/recharge cycles POWER CONTROL ENCLOSED UPS INTERFACE MODULE PSH2C2RB10-L Enclosed 2.75 Track Mount Power Control Center, with 10 Amp Switch / Circuit Breaker, Two (2) 120 Vac Outlets, Terminals, 120 Vac Input. (Status Contacts) UPS Status Contacts & 120 Vac LED Indicator Line Input Input Power Status Contacts & LED Indicator } GND } Neut. Line N/C } COM N/O N/C COM N/O UPS (Not Included) GND Neut. Line RESET OFF Line Neut. GND From UPS Backed Up Outlet } To Protected Device To UPS UPS plugged into one of two outlets. Other outlet spare. } Shown Without Cover Shown With Cover Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Operating Temperature: -30 to 140° F Line Input Status Contacts and UPS Notes: Humidity Range: 5 to 95% (noncondensing) Output Status Contacts Rated: · Track mounted interface board may be ordered separately as Main Breaker ON/OFF: Switch / Breaker (10 Amp) 10 Amp @ 277 Vac General Use model PSMN2C2RB10, to be used with any commercial UPS Approvals: UL Listed, UL916, C-UL, CE, RoHS 10 Amp @ 30 Vdc N/O with appropriate ratings for the circuit breaker. Dimensions: 14.000 x 16.000 x 6.000 7 Amp @ 30 Vdc N/C · Circuit breaker for short-circuit protection. Metal Housing with Screw Cover 1/2 HP @ 125 Vac · 14/3 Line Cord included (3´). Weight: 14.76 lbs. 1/4 HP @ 277 Vac · Use with UPS devices rated 1000 VA or less. 1000 VA @ 120 Vac Magnetic Ballast N/C · Max. size: 14.000 x 10.000 x 5.500 C300 Pilot Duty · 120 Vac, 600 W max., 8.3 Amp max. 16.8 VA @ 24 Vac Pilot Duty · UPS is not included. · To order a kit with a UPS, see PSH850-UPS-STAT. (800) 888-5538 | www.functionaldevices.com 139 Notes POWER CONTROL 140 Functional Devices, Inc. | American Made. American Owned. ENCLOSURES Plastic | Metal Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). NEMA 1 and NEMA 4 Metal & Plastic Enclosures · All enclosures are NEMA 1 or NEMA 4 rated and are UL Listed. Smaller enclosures have an abundance of knockouts and metal enclosures are stackable vertically and horizontally. Available in a variety of sizes, these enclosures provide many useful features. Small metal enclosure sizes have screw covers and the larger sizes are equipped with key-lock latch doors, most of which are full-hinge. ENCLOSURES MODEL # PE6000 Series MH1000 Series MH1200 Series MH2204-N4 MH3100-M1 MH3204-N4 MH3300 Series MH3500 Series MH3800 Series MH4400 Series MH5500 Series MH5800 Series NEMA RATING · NEMA 1 / NEMA 4/4X COVER / DOOR Screw Down Cover · NEMA 1 Screw Down Cover · NEMA 1 Screw Down Cover · NEMA 4/4X Hinge Key Latch Door · NEMA 1 Screw Down Cover · NEMA 4/4X Hinge Key Latch Door · NEMA 1 Vertical Lift Screw Down Cover · NEMA 1 Reversible Hook Hinge Key Latch Door · NEMA 1 Reversible Hook Hinge Key Latch Door · NEMA 1 Full Hinge Key Latch Door · NEMA 1 Full Hinge Key Latch Door · NEMA 1 Full Hinge Key Latch Door HEIGHT 4.28 14.50 8.30 9.84 12.00 15.75 12.50 24.50 24.50 18.00 25.00 36.00 = UL Listed : UL916 Energy Management ; USA & Canada WIDTH 7.00 7.70 7.70 7.87 12.00 11.81 12.50 10.25 12.50 18.00 25.00 25.00 DEPTH 2.00 3.90 3.90 3.98 6.00 5.91 7.00 3.90 6.50 7.00 9.50 9.50 GAUGE 18 18 16 16 16 18 18 18 16 14 14 NOTES SPEC PAGE 141 142 142 142 143 143 143 144 144 144 145 145 ENCLOSURES ENCLOSURE PE6000 Series Plastic Housing, .75 NPT Nipple, 4.28 H x 7.00 W x 2.00 D 7.00" 2.00" 4.28" SPECIFICATIONS Cover Type: Screw Down Cover Approvals: UL Listed, C-UL, CE Approved, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1, Also available NEMA 4 / 4X 7.00" 2.00" MT212-6 Plastic Snap Track 7.00" MT4-4 Plastic Snap Track 4.28" 4.28" Made in USA Meets "Buy American" of ARRA 2009 2.00" PE6000 SERIES ASSEMBLIES Model # Enclosure Plastic Snap Track NEMA Type Weight PE6000 PE6000 NEMA 1 .656 lbs. PE6010 PE6000 MT4-4 (4.00"W) NEMA 1 .717 lbs. PE6020 PE6000 MT212-6 (2.75"W) NEMA 1 .769 lbs. PE6000-N4 PE6000-N4 NEMA 4/4X .656 lbs. PE6010-N4 PE6000-N4 MT4-4 (4.00"W) NEMA 4/4X .717 lbs. PE6020-N4 PE6000-N4 MT212-6 (2.75"W) NEMA 4/4X .769 lbs. Notes: · Comes with transparent lid. To order with gray opaque lid, add "-GY" to end of model number. (800) 888-5538 | www.functionaldevices.com 141 ENCLOSURES ENCLOSURE MH1000 Series Metal Housing, NEMA 1, 14.50 H x 7.70 W x 3.90 D 7.70" 5.70" 14.50" 11.50" 14.50" 3.90" 7.70" SPECIFICATIONS Construction: 18 Gauge Steel Cover Type: Screw Down Cover Approvals: UL Listed, C-UL, CE Approved, RoHS ENCLOSURE MH1200 Series Metal Housing, NEMA 1, 8.30 H x 7.70 W x 3.90 D MH1000 SERIES ASSEMBLIES Model # Enclosure Plastic Snap Track Weight MH1000 MH1000 6.00 lbs. MH1010 MH1000 MT4-12 (4.00"W) 6.30 lbs. MH1020 MH1000 MT212-12 (2.75"W) 6.25 lbs. Notes: · Consult factory for custom colors for large orders. 7.70" 5.70" 8.30" 8.30" 5.30" 3.90" 7.70" SPECIFICATIONS Construction: 18 Gauge Steel Cover Type: Screw Down Cover Approvals: UL Listed, C-UL, CE Approved, RoHS MH1200 SERIES ASSEMBLIES Model # Enclosure Plastic Snap Track Weight MH1200 MH1200 3.86 lbs. MH1210 MH1200 MT4-8 (4.00"W) 4.06 lbs. MH1220 MH1200 MT212-8 (2.75"W) 4.00 lbs. Notes: · Consult factory for custom colors for large orders. ENCLOSURE MH2204-N4 Metal Housing, NEMA 4/4X, 9.84 H x 7.87 W x 3.98 D 3.98" 7.880" 6.420" 7.870" 5.928" 14 Gauge Steel Sub-Panel 4.500" 9.840" 11.140" 8.580" 4 Brackets .437" x .687" Oblong SPECIFICATIONS Construction: 16 Gauge Steel Weight: 7.70 lbs. Cover Type: Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS 142 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 ENCLOSURE MH3100-M1 Metal Housing, NEMA 1, 12.00 H x 12.00 W x 6.00 D, Mounting Option 1 6.00" 1/4"-20 Threaded Stud 1.00" H Max. 8-32 Threaded Stud .375"H 12.00" 12.00" 12.00" MH3100-M1 ASSEMBLY Model # Enclosure Plastic Snap Track MH3100-M1 * MH3100 6 Threaded Studs * MH3100-M1 + PSMN500A = PSH500A MH3100-M1 + PSMN300A = PSH300A SPECIFICATIONS Construction: 16 Gauge Steel Weight: 12 lbs. Cover Type: Screw Down Cover Approvals: UL Listed, C-UL, CE Approved, RoHS Notes: · To convert panel-mounted power supply to enclosed, simply remove the sub-panel and mount to enclosure with provided screw pack. * ENCLOSURE MH3204-N4 Metal Housing, NEMA 4/4X, 15.75 H x 11.81 W x 5.91 D 6.355" 15.75" 16.93" 14.37" 5.910" 11.811" 10.352" 11.811" 9.86" 14 Gauge Steel Sub-Panel 4 Brackets .437" x .687" Oblong SPECIFICATIONS Construction: 16 Gauge Steel Weight: 17 lbs. Cover Type: Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS ENCLOSURE MH3300 Series Metal Housing, NEMA 1, 12.50 H x 12.50 W x 7.00 D 7.00" 12.75" 12.50" 12.50" 12.50" MH3300 SERIES ASSEMBLIES Model # MH3300 MH3300K MH3303 MH3304 MH3303K MH3304K Enclosure MH3300 MH3300K MH3300 MH3300 MH3300K MH3300K Cover Type Vertical Lift Screw Down Vertical Lift Key Latch Vertical Lift Screw Down Vertical Lift Screw Down Vertical Lift Key Latch Vertical Lift Key Latch Sub-Panel SP3303 1 SP3304 2 SP3303 1 SP3304 2 Weight 10.5 lbs. 10.7 lbs. 11.8 lbs. 11.8 lbs. 12.5 lbs. 12.5 lbs. 1 = Polymetal 11.33" H x 11.40" W 2 = Perforated Steel 11.33" H x 11.40" W SPECIFICATIONS Construction: 18 Gauge Steel Approvals: UL Listed, C-UL, CE Approved, RoHS Notes: · Consult factory for custom colors for large orders. (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 143 ENCLOSURES ENCLOSURES 22.00" 24.50" ENCLOSURE MH3500 Series Metal Housing, NEMA 1, 24.50 H x 10.25 W x 3.90 D 10.25" 8.35" 10.25" 22.00" 24.50" MH3500 SERIES ASSEMBLIES Model # Enclosure Plastic Snap Track Weight MH3500 MH3500 11.1 lbs. MH3510 MH3500 MT4-24 (4.00"W) 11.7 lbs. MH3520 MH3500 MT212-24 (2.75"W) 11.5 lbs. 3.90" SPECIFICATIONS Construction: 18 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS ENCLOSURE MH3800 Series Metal Housing, NEMA 1, 24.50 H x 12.50 W x 6.50 D Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number. 10.60" 6.50" 12.50" 12.50" Model # MH3800 MH3810 MH3820 MH3803S MH3803L MH3804S MH3804L MH3800 SERIES ASSEMBLIES Enclosure Plastic Snap Track / Sub-Panel Weight MH3800 16.6 lbs. MH3800 MT4-18 (4.00"W) 16.9 lbs. MH3800 MH3800 MH3800 MH3800 MH3800 MT212-18 (2.75"W) SP3803S 1 SP3803L 1 SP3804S 2 SP3804L 2 16.8 lbs. 18.1 lbs. 18.5 lbs. 19.9 lbs. 20.3 lbs. 1 = Polymetal Model S: 19.00" H x 11.75" W Model L: 23.00" H x 11.75" W 2 = Perforated Steel Model S: 19.00" H x 11.75" W Model L: 23.00" H x 11.75" W SPECIFICATIONS Construction: 18 Gauge Steel Cover Type: Reversible Hook Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number. ENCLOSURE MH4400 Series Metal Housing, NEMA 1, 18.00 H x 18.00 W x 7.00 D 13.50" 18.00" 16.00" 18.00" 18.00" MH4400 SERIES ASSEMBLIES Model # Enclosure Sub-Panel Weight MH4400 MH4403L MH4404L MH4400 MH4400 MH4400 SP4403L 1 SP4404L 2 22.5 lbs. 24.7 lbs. 26.3 lbs. 1 = Polymetal 16.875" H x 15.75" W 2 = Perforated Steel 16.875" H x 15.75" W 7.00" SPECIFICATIONS Construction: 16 Gauge Steel Cover Type: Full Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number. 144 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 ENCLOSURE MH5500 Series Metal Housing, NEMA 1, 25.00 H x 25.00 W x 9.50 D 25.00" 25.00" 25.00" 22.50" 9.50" 23.10" SPECIFICATIONS Construction: 14 Gauge Steel Cover Type: Full Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS MH5500 SERIES ASSEMBLIES Model # MH5500 MH5503L MH5504L Enclosure MH5500 MH5500 MH5500 Sub-Panel SP5503L 1 SP5504L 2 Weight 50.7 lbs. 56.4 lbs. 60.0 lbs. 1 = Polymetal 23.00" H x 22.50" W 2 = Perforated Steel 23.00" H x 22.50" W Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number. ENCLOSURE MH5800 Series Metal Housing, NEMA 1, 36.00 H x 25.00 W x 9.50 D 33.50" 25.00" 23.10" 36.00" 25.00" MH5800 SERIES ASSEMBLIES Model # Enclosure Sub-Panel Weight MH5800 MH5803L MH5804L MH5800 MH5800 MH5800 SP5803L 1 SP5804L 2 68.5 lbs. 74.2 lbs. 80.8 lbs. 1 = Polymetal 34.125" H x 22.50" W 2 = Perforated Steel 34.125" H x 22.50" W 9.50" SPECIFICATIONS Construction: 14 Gauge Steel Cover Type: Full Hinge Key Latch Door Approvals: UL Listed, C-UL, CE Approved, RoHS Notes: · Consult factory for custom colors for large orders. · Order with coin latch by adding "-L4" to end of model number. Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 ENCLOSURES (800) 888-5538 | www.functionaldevices.com 145 Notes ENCLOSURES 146 Functional Devices, Inc. | American Made. American Owned. ACCESSORIES Sub-Panels | Mounting Supplies | Replacement Parts Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Sub-Panels · Two types of sub-panel material are available - polymetal and perforated steel. Both the polymetal and perforated steel subpanels are Plenum Rated and designed to mount in model "MH" metal housings and the mounting holes are pre-drilled, ready to install. Sub-panels can be ordered pre-installed in your choice of "MH" enclosures. See the general specifications for pre-assembled enclosure kit model numbers. Replacement Parts · Replacement parts are available for several products including remote sensors, enclosures, and more. Mounting Supplies · Mounting options include plastic track for snapmounting circuit boards. One style of track can be mounted to the back surface of any cabinet and is available in 4.00" or 2.75" widths. Another style of track, AdapTrack®, snaps onto any of the three most popular DIN rails. In turn, it can accomodate a 4.00" wide circuit board. SUB-PANELS MODEL # SP3303 SP3304 SP3803S SP3803L SP3804S SP3804L SP4403L SP4404L SP5503L SP5504L SP5803L SP5804L USE WITH ENCLOSURE MH3300 or MH3300K MH3300 or MH3300K MH3800 MH3800 MH3800 MH3800 MH4400 MH4400 MH5500 MH5500 MH5800 MH5800 MATERIAL Polymetal Perforated Steel Polymetal Polymetal Perforated Steel Perforated Steel Polymetal Perforated Steel Polymetal Perforated Steel Polymetal Perforated Steel HEIGHT 11.330 11.330 19.000 23.000 19.000 23.000 16.875 16.875 23.000 23.000 34.125 34.125 WIDTH 11.400 11.400 11.750 11.750 11.750 11.750 15.750 15.750 22.500 22.500 22.500 22.500 THICKNESS MOUNTING AREA .130 129.16 square .250 129.16 square .130 223.25 square .130 270.25 square .250 223.25 square .250 270.25 square .130 265.78 square .250 265.78 square .130 517.50 square .250 517.50 square .130 767.81 square .250 767.81 square WEIGHT .932 lbs. 1.662 lbs. 1.705 lbs. 2.140 lbs. 2.940 lbs. 3.520 lbs. 2.100 lbs. 3.520 lbs. 3.940 lbs. 6.560 lbs. 5.875 lbs. 9.720 lbs. NOTES SPEC PAGE 148 148 148 149 149 149 150 150 150 151 151 151 MOUNTING SUPPLIES MODEL # MT212 Series MT4 Series AT4 Series DS8062 DESCRIPTION · 2.75 wide screw mounted snap-in track for mounting relays, current sensors and power supplies · 4.00 wide screw mounted snap-in track for mounting relays, current sensors and power supplies · 4.00 wide AdapTrack® for DIN rail mounting relays, current sensors and power supplies Self-tapping 5/8 drill screws for mounting devices to all polymetal sub-panels NOTES 1 SPEC PAGE 152 152 152 153 REPLACEMENT PARTS MODEL # MKL Series KEYSET AXK AXKT AXG AXGT AXR TS-AN APS53-TC DESCRIPTION Locking latch assemblies for use with Functional Devices metal enclosures One set of 2 keys for use with any of the key latch metal enclosures Remote mini current sensor assembly (Wire Output) Remote mini current sensor assembly (Terminal Output) Split ring remote current sensor assembly (Wire Output) Split ring remote current sensor assembly (Terminal Output) Remote current sensor assembly (Wire Output) Pluggable terminal strips for RIBAN Series Primary voltage terminal cover for use with 300 VA and 500 VA power supplies = UL Component Recognized ; USA & Canada 1 = Does not meet "Buy American" of ARRA 2009 (800) 888-5538 | www.functionaldevices.com NOTES 1 1 SPEC PAGE 153 153 153 153 153 153 153 153 153 147 ACCESSORIES SUB-PANEL SP3303 Polymetal Sub-Panel, 11.330 H x 11.400 W x .130 Thick 11.4000" Made in USA Meets "Buy American" of ARRA 2009 11.3300" 10.2050" 2.5000" 6.4000" 2.5000" .5625" SPECIFICATIONS Mounting Area: 129.16 square Weight: .932 lbs. Approvals: Plenum Rated Enclosure Assemblies: MH3303 MH3300 Enclosure with SP3303 Sub-Panel pre-mounted MH3303K MH3300K Enclosure with SP3303 Sub-Panel pre-mounted SUB-PANEL SP3304 Perforated Steel Sub-Panel, 11.330 H x 11.400 W x .250 Thick 11.4000" Made in USA Meets "Buy American" of ARRA 2009 11.3300" 10.2050" 2.5000" 6.4000" 2.5000" .5625" SPECIFICATIONS Mounting Area: 129.16 square Weight: 1.662 lbs. Approvals: Plenum Rated Enclosure Assemblies: MH3304 MH3300 Enclosure with SP3304 Sub-Panel pre-mounted MH3304K MH3300K Enclosure with SP3304 Sub-Panel pre-mounted SUB-PANEL SP3803S Polymetal Sub-Panel, 19.000 H x 11.750 W x .130 Thick 11.7500" 9.0000" 10.7500" .5000" Made in USA Meets "Buy American" of ARRA 2009 19.0000" 9.0000" 8.5000" .5000" SPECIFICATIONS Mounting Area: 223.25 square Weight: 1.705 lbs. Approvals: Plenum Rated 148 Enclosure Assemblies: MH3803S MH3800 Enclosure with SP3803S Sub-Panel pre-mounted Functional Devices, Inc. | American Made. American Owned. ACCESSORIES SUB-PANEL SP3804S Perforated Steel Sub-Panel, 19.000 H x 11.750 W x .250 Thick 11.7500" 9.0000" 10.7500" .5000" 19.0000" 9.0000" 8.5000" .5000" SPECIFICATIONS Mounting Area: 223.25 square Weight: 2.94 lbs. Approvals: Plenum Rated Enclosure Assemblies: MH3804S MH3800 Enclosure with SP3804S Sub-Panel pre-mounted SUB-PANEL SP3803L Polymetal Sub-Panel, 23.000 H x 11.750 W x .130 Thick 11.7500" 4.5000" 10.7500" .5000" 9.000" 23.000" 9.000" 8.5000" .5000" SPECIFICATIONS Mounting Area: 270.25 square Weight: 2.14 lbs. Approvals: Plenum Rated Enclosure Assemblies: MH3803L MH3800 Enclosure with SP3803L Sub-Panel pre-mounted SUB-PANEL SP3804L Perforated Steel Sub-Panel, 23.000 H x 11.750 W x .250 Thick 11.7500" 4.5000" 10.7500" .5000" 9.000" 23.000" 9.000" 8.5000" .5000" SPECIFICATIONS Mounting Area: 270.25 square Weight: 3.52 lbs. Approvals: Plenum Rated Enclosure Assemblies: MH3804L MH3800 Enclosure with SP3304L Sub-Panel pre-mounted (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 149 ACCESSORIES ACCESSORIES SUB-PANEL SP4403L Polymetal Sub-Panel, 16.875 H x 15.750 W x .130 Thick 15.7500" 14.3750" .7500" 16.8750" 15.3750" .7500" SPECIFICATIONS Mounting Area: 265.78 square Weight: 2.10 lbs. Approvals: Plenum Rated Enclosure Assemblies: MH4403L MH4400 Enclosure with SP4403L Sub-Panel pre-mounted SUB-PANEL SP4404L Perforated Steel Sub-Panel, 16.875 H x 15.750 W x .250 Thick 15.7500" 14.3750" .7500" 16.8750" 15.3750" .7500" SPECIFICATIONS Mounting Area: 265.78 square Weight: 3.52 lbs. Approvals: Plenum Rated Enclosure Assemblies: MH4404L MH4400 Enclosure with SP4404L Sub-Panel pre-mounted SUB-PANEL SP5503L Polymetal Sub-Panel, 23.000 H x 22.500 W x .130 Thick 22.5000" 10.7500" 10.5000" 10.5000" .7500" 23.0000" 10.7500" .7500" SPECIFICATIONS Mounting Area: 517.50 square Weight: 3.94 lbs. Approvals: Plenum Rated 150 Enclosure Assemblies: MH5503L MH5500 Enclosure with SP5503L Sub-Panel pre-mounted Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 SUB-PANEL SP5504L Perforated Steel Sub-Panel, 23.000 H x 22.500 W x .250 Thick 22.5000" 10.7500" 10.5000" 10.5000" .7500" 23.0000" 10.7500" .7500" SPECIFICATIONS Mounting Area: 517.50 square Weight: 6.56 lbs. Approvals: Plenum Rated Enclosure Assemblies: MH5504L MH5500 Enclosure with SP5504L Sub-Panel pre-mounted SUB-PANEL SP5803L Polymetal Sub-Panel, 34.125 H x 22.500 W x .130 Thick 22.5000" 10.5000" 10.5000" .7500" 16.2500" 34.1250" 16.2500" .7500" SPECIFICATIONS Mounting Area: 767.81 square Weight: 5.875 lbs. Approvals: Plenum Rated Enclosure Assemblies: MH5803L MH5800 Enclosure with SP5803L Sub-Panel pre-mounted SUB-PANEL SP5804L Perforated Steel Sub-Panel, 34.125 H x 22.500 W x .250 Thick 22.5000" 10.5000" 10.5000" .7500" 16.2500" 34.1250" 16.2500" .7500" SPECIFICATIONS Mounting Area: 767.81 square Weight: 9.72 lbs. Approvals: Plenum Rated Enclosure Assemblies: MH5804L MH5800 Enclosure with SP5804L Sub-Panel pre-mounted (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 Made in USA Meets "Buy American" of ARRA 2009 151 ACCESSORIES 4.00" 2.75" MOUNTING TRACK MT212 Series 2.75 Wide Mounting Track for Relays, Current Sensors, and Power Supplies Length 2.00" SPECIFICATIONS Flame Rated: 94-5V Approvals: UL Component Recognized, USA & Canada CE Approved, RoHS Mounting: MT212 Series track can be screw-mounted to any flat surface to provide mounting for 2.75 wide track-mountable relays, current sensors, or power supplies. MOUNTING TRACK MT4 Series 4.00 Wide Mounting Track for Relays, Current Sensors, and Power Supplies Length 2.00" SPECIFICATIONS Flame Rated: 94-5V Approvals: UL Component Recognized, USA & Canada CE Approved, RoHS Mounting: MT4 Series track can be screw-mounted to any flat surface to provide mounting for 4.00 wide track-mountable relays, current sensors, or power supplies. MOUNTING TRACK AT4 Series 4.00 Wide AdapTrack® for Relays, Current Sensors, and Power Supplies Length Made in USA Meets "Buy American" of ARRA 2009 MT212 SERIES SELECTION GUIDE Model # Width Length Distance Between Hole Centers MT212-2 2.75 2.00 2.00 Center to Center MT212-4 2.75 4.00 2.00 Center to Center MT212-6 2.75 6.00 2.00 Center to Center MT212-8 2.75 8.00 2.00 Center to Center MT212-12 2.75 12.00 2.00 Center to Center MT212-18 2.75 18.00 2.00 Center to Center MT212-24 2.75 24.00 2.00 Center to Center MT212-48 2.75 48.00 2.00 Center to Center Made in USA Meets "Buy American" of ARRA 2009 MT4 SERIES SELECTION GUIDE Model # Width Length Distance Between Hole Centers MT4-2 4.00 2.00 2.00 Center to Center MT4-4 4.00 4.00 2.00 Center to Center MT4-6 4.00 6.00 2.00 Center to Center MT4-8 4.00 8.00 2.00 Center to Center MT4-12 4.00 12.00 2.00 Center to Center MT4-18 4.00 18.00 2.00 Center to Center MT4-24 4.00 24.00 2.00 Center to Center MT4-48 4.00 48.00 2.00 Center to Center Made in USA Meets "Buy American" of ARRA 2009 ACCESSORIES 4.00" SPECIFICATIONS Flame Rated: 94-5V DIN Rail Sizes: 32 mm x 15 mm asymmetrical DIN rail EN50035 35 mm x 7.5 mm symmetrical DIN rail EN50022 22.4 mm x 6.9 mm symmetrical NEMA A Series rail Approvals: UL Component Recognized, USA & Canada CE Approved, RoHS Mounting: AT4 Series AdapTrack® snaps onto the three most common DIN rail sizes to provide mounting for 4.00 wide track-mountable relays, current sensors, or power supplies. AT4 SERIES SELECTION GUIDE Model # Width Length DIN Rail Sizes AT4-2 4.00 2.00 3 Most Common (see general specs to the left) AT4-6 4.00 6.00 3 Most Common (see general specs to the left) AT4-12 4.00 12.00 3 Most Common (see general specs to the left) AT4-24 4.00 24.00 3 Most Common (see general specs to the left) AT4-48 4.00 48.00 3 Most Common (see general specs to the left) 152 Functional Devices, Inc. | American Made. American Owned. MKL Series Lock Assemblies for use with RIB® Metal Enclosures LOCK ASSEMBLIES KEYSET Set of Two Replacement Keys KEY SET MKL-1 Locking key-latch assembly for use with all metal enclosures except MH3300K MKL-2 Locking key-hook latch assembly for use with metal enclosure MH3300K MKL-3 Metal locking key-latch assembly for use with all metal enclosures except MH3300K MKL-4 Coin locking key-latch assembly for use with all metal enclosures except MH3300K SPECIFICATIONS Quantity: Two keys and one ring per set For Use With: Any of the key-lock enclosures Advantages: Works with any Functional Devices, Inc. key-lock enclosures DS80625 Number 8 Self-Tapping Drill Screws SPECIFICATIONS Size: No. 8 x 5/8 For Use With: All polymetal sub-panels Advantages: Self-tapping, eliminates mushrooming SCREW SET AXK Replacement for any damaged or lost sensor. For use with models listed below * SPECIFICATIONS REPLACEMENT Made in USA Meets "Buy American" of ARRA 2009 Dimensions: (Inside Diameter) .50 (Outside) 1.86 x 1.46 x 1.50 *Only For Use With: RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF Purpose: Can replace any damaged or lost sensor. For use with the models listed above. AXKT Replacement for any damaged or lost sensor. For use with models listed below * SPECIFICATIONS REPLACEMENT Made in USA Meets "Buy American" of ARRA 2009 Dimensions: (Inside Diameter) .50 (Outside) 2.05 x 1.46 x 1.50 *Only For Use With: RIBXLCRA, RIBXLCRF, RIBXLSRA, RIBXLSRF, RIBXRA, RIBXRF Purpose: Can replace any damaged or lost sensor. For use with the models listed above. AXG Replacement for any damaged or lost sensor. For use with models listed below * REPLACEMENT SPECIFICATIONS Dimensions: (Inside) .52 x .52 (Outside) 2.52 x 2.00 x 1.75 *Only For Use With: RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF Purpose: Can replace any damaged or lost sensor. For use with the models listed above. Made in USA Meets "Buy American" of ARRA 2009 AXGT Replacement for any damaged or lost sensor. For use with models listed below * REPLACEMENT SPECIFICATIONS Dimensions: (Inside) .52 x .52 (Outside) 2.52 x 2.00 x 1.75 *Only For Use With: RIBXJA, RIBXJF, RIBXLCJA, RIBXLCJF, RIBXLSJA, RIBXLSJF Purpose: Can replace any damaged or lost sensor. For use with the models listed above. Made in USA Meets "Buy American" of ARRA 2009 AXR Replacement for any damaged or lost sensor. For use with models listed below * REPLACEMENT SPECIFICATIONS Dimensions: (Inside Diameter) .75 (Outside Diameter) 2.28 *Only For Use With: RIBMXRA, RIBMXRF Purpose: Can replace any damaged or lost sensor. For use with the models listed above. Made in USA Meets "Buy American" of ARRA 2009 ACCESSORIES TS-AN Replacement for any damaged or lost pluggable terminal strips for RIBAN Series. For use with models listed below * REPLACEMENT SPECIFICATIONS *Only For Use With: RIBAN12C, RIBAN24C Installation Instructions: Plug the terminal strips into the headers found on the RIBAN Series product. Made in USA Meets "Buy American" of ARRA 2009 APS53-TC Primary Voltage Terminal Cover for use with 300 VA and 500 VA Power Supplies TERMINAL COVER Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Includes: (2) Self-Tapping Drill Screws for Installation For Use With: PSMN300A, PSMN300A-IC, PSMN500A, PSMN500A-IC, PSH300A, PSH300A-IC, PSH500A, PSH500A-IC (800) 888-5538 | www.functionaldevices.com 153 Notes ACCESSORIES 154 Functional Devices, Inc. | American Made. American Owned. WIRELESS DEVICES Short Range Wireless Devices · EnOcean® enabled wireless relay receivers work in conjunction with many switching devices that are EnOcean® enabled with 902 MHz transmitters. · Wireless wall switches, occupancy sensors, thermostats, key card switches, patio and door switches are all devices which can activate the RIB® wireless control relays by using EnOcean's "energy harvesting" technology. Energy harvesting refers to the process by which energy is captured and stored, then used to transmit a wireless signal, which in turn is received by the RIB® wireless relay. Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). WIRELESS DEVICES WIRELESS CONTROL RELAYS COIL VOLTAGE MODEL # RIBW01B-EN3 · RIBW208B-EN3 · RIBW240B-EN3 · RIBW277B-EN3 · RIBW24B-EN3 RIBW01C-EN3 · RIBW02C-EN3 · AC/DC 24 AC 120 208 240 277 120 208-277 RELAYS 1 1 1 1 1 1 1 CONTACTS SPDT SPDT SPDT SPDT SPDT SPST SPST REPEAT FUNCTION · · · · · · · DRY CONTACT INPUT · · · · · BALLAST SIZE ENCLOSURE · · NOTES NEW NEW NEW NEW NEW NEW NEW SPEC PAGE 156 156 156 156 156 157 157 WIRELESS TRANSMITTERS MODEL # WWS-EN3 WDWS-EN3 POWER INPUT Self-Powered Self-Powered ENOCEAN® ENERGY HARVESTING · · FREQUENCY 902 MHz 902 MHz COLOR White White WIRELESS SWITCH COVER PLATE 1 WSTP-W NOTES NEW NEW SPEC PAGE 157 158 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 1 = Sold separately * For other loads, see data sheet. (800) 888-5538 | www.functionaldevices.com 155 WIRELESS CONTROL RELAYS WITH TWO-WAY COMMUNICATION RIBW01B-EN3 Enclosed EnOcean® Enabled Wireless Relay Transceiver / Repeater 20 Amp SPDT, 120 Vac Power, with Dry Contact Input RIBW208B-EN3 Enclosed EnOcean® Enabled Wireless Relay Transceiver / Repeater 20 Amp SPDT, 208 Vac Power, with Dry Contact Input RIBW240B-EN3 Enclosed EnOcean® Enabled Wireless Relay Transceiver / Repeater 20 Amp SPDT, 240 Vac Power, with Dry Contact Input RIBW277B-EN3 Enclosed EnOcean® Enabled Wireless Relay Transceiver / Repeater 20 Amp SPDT, 277 Vac Power, with Dry Contact Input RIBW24B-EN3 Enclosed EnOcean® Enabled Wireless Relay Transceiver / Repeater 20 Amp SPDT, 24 Vac/dc Power, with Dry Contact Input Blk 120, 208, 240, or 277 Vac Red Wht or Neutral or Neutral Other Phase Wireless Receiver Control Circuit Blu N/C Yel Comm Org N/O Wht/Red Wht/Blu RIBW01B-EN3 RIBW208B-EN3 RIBW240B-EN3 RIBW277B-EN3 Wht/Yel 24 Vac/dc Wht/Yel 24 Vac/dc Wht/Red Wht/Blu Wireless Receiver Control Circuit Blu N/C Yel Comm Org N/O RIBW24B-EN3 Learn Clear Made in USA Meets "Buy American" of ARRA 2009 RELAY HAS BUILT-IN REPEATER FUNCTION. RELAY RECEIVES SIGNAL FROM WIRELESS SWITCH TRANSMITTER AND REBROADCASTS THE SIGNAL TO THE NEXT RELAY RECEIVER. SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Red LED: Relay Status / Learn Mode Status (Flashing) Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, RoHS, Agency Compliance: FCCID: SZV-TCM3200 IC: 5713A-TCM3200 Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Frequency: 902 MHz Receiver Sensitivity: -93 dBm typical Conducted Power: 5 mW typical Built-in Switch Modes: Alarm, Repeater, Delay, Rocker, Momentary, and Toggle Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 73 mA @ 120 Vac ; 60 Hz (RIBW01B-EN3) 80 mA @ 208 Vac ; 60 Hz (RIBW208B-EN3) 80 mA @ 240 Vac ; 60 Hz (RIBW240B-EN3) 80 mA @ 277 Vac ; 60 Hz (RIBW277B-EN3) 139 mA @ 24 Vac (RIBW24B-EN3) 69 mA @ 24 Vdc (RIBW24B-EN3) Notes: · Compatible with Enocean® 902 MHz Switches/Transmitters. · Typical range: 50-150 ft. · Open area transmission could be farther. Consult factory for more information. · Repeater function only rebroadcasts original EnOcean® transmission. Up to two repeaters can be used. · Version 1.5 firmware or later implements Functional Devices, Inc.'s EnOcean® Manufacturer ID of 0x055. · For setup instructions, see website for -EN3 Series Application Manual: www.functionaldevices.com/pdf/bulletins/B1867_393231.pdf or scan QR code with your smart phone. WIRELESS DEVICES BAS Controller Org Yel APPLICATION FOR WIRELESS CONTROL & FEEDBACK IN A BUILDING AUTOMATION SYSTEM BAS Panel Org Wht/Red and Wht/Blu DO Blk Wht or Red 60Hz A/C Power DI Yel Load Current Sensor Wht/Red Wht/Blu Dry contact input for load veri cation 156 Functional Devices, Inc. | American Made. American Owned. WIRELESS CONTROL RELAYS WITH TWO-WAY COMMUNICATION RIBW01C-EN3 Enclosed EnOcean® Enabled Wireless Relay Receiver / Repeater 5 Amp SPST-N/O, 120 Vac Power Input RIBW02C-EN3 Enclosed EnOcean® Enabled Wireless Relay Receiver / Repeater 5 Amp SPST-N/O, 208-277 Vac Power Input Made in USA Meets "Buy American" of ARRA 2009 Org N/O Blk 120 Vac Wireless Org Receiver N/O Wht Control Neutral Circuit Org N/O Blk 208-277 Vac Wireless Org Red Neutral or Receiver Control N/O Other Phase Circuit SMALLER SIZE DESIGN TO FIT INSIDE BALLAST HOUSING OF FLUORESCENT LIGHT FIXTURE. SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Red LED: Relay Status / Learn Mode Status (Flashing) Dimensions: 4.60 x 1.20 x 1.70 Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL Agency Compliance: FCCID: SZV-TCM3200 IC: 5713A-TCM3200 Gold Flash: No Override Switch: No Frequency: 902 MHz Receiver Sensitivity: -93 dBm typical Conducted Power: 5 mW typical Built-in Switch Modes: Alarm, Repeater, Delay, Rocker, Momentary, and Toggle Contact Ratings: 5 Amp Ballast @ 120/277 Vac 5 Amp Tungsten @ 120 Vac 5 Amp Electronic Ballast @ 120 Vac Power Input Ratings: 75 mA @ 120 Vac ; 60 Hz (RIBW01C-EN3) 100 mA @ 208-277 Vac ; 60 Hz (RIBW02C-EN3) Notes: · Compatible with Enocean® 902 MHz Switches/Transmitters. · Typical range: 50-150 ft. · Open area transmission could be farther. Consult factory for more information. · Repeater function only rebroadcasts original EnOcean® transmission. Up to two repeaters can be used. · Version 1.5 firmware or later implements Functional Devices, Inc.'s EnOcean® Manufacturer ID of 0x055. · For setup instructions, see website for -EN3 Series: www.functionaldevices.com/pdf/bulletins/B1867_393231.pdf or scan QR code with your smart phone. WIRELESS DEVICES WIRELESS ROCKER SWITCH TRANSMITTER & COVER PLATE WWS-EN3 EnOcean® Enabled Wireless Wall Switch Transmitter Switch, 902 MHz Switch Colors Available: WSTP-W Cover Plate Colors Available: White White SPECIFICATIONS Operating Modes: On/Off, Toggle, Scene control Power Supply: Powered by finger press (Electrodynamic Energy Harvester) Frequency: 902 MHz Antenna: Integrated antenna, 15cm Transmission Power: Max. 10mw EIRP Energy Bowtravel/Operating Force: 50,000 actuations tested to EN60669 / VDE 0632 Operating Temperature: -25 to 65° C Relative Humidity 5 to 92% (noncondensing) Dimensions: 2.75 x 4.50 x 0.62 Weight: 3 oz. Agency Compliance: FCCID: SZV-PTM 210U IC: 5713A-PTM210U Notes: · Control one load or one group of loads with a single rocker style Wireless Switch Transmitter. · Typical range: 50-150 ft. · Open area transmission could be farther. Consult factory for more information. · Switch cover plate sold separately. · Do not use metal switch plate covers due to interference with wireless signal. · Mount with screws or double sided tape. · For use with EN3 Series Relays. · EEP F6-02-02 (800) 888-5538 | www.functionaldevices.com 157 WIRELESS SOLAR DOOR / WINDOW TRANSMITTER WDWS-EN3 EnOcean® Enabled Wireless Solar Door / Window Sensor, 902 MHz SPECIFICATIONS Charge Time before Linking: 2.7 hours @ 10 lux 3.7 minutes @ 200 lux Light Required to Sustain Operation: 15 lux for 6 actuations/hour 50 lux for 30 actuations/hour 100 lux for 60 actuations/hour Charge Time for Full Charge: 21 hours @ 200 lux (after startup) 42 hours @ 200 lux (cold start) Operating Life in Darkness (after full charge): 174 hours heartbeat only 67 hours @ 10 actuations/hour 10 hours @ 100 actuations/hour Maximum Sensor Gap: 0.25" (6.4mm) Dimensions (Sensor): 3.15" L x 0.83"W x 0.59" D (80mm x 21mm x 15mm) Dimensions (Magnet): 3.15" L x 0.47"W x 0.50" D (80mm x 12mm x 13mm) Weight (Total): 0.97 oz. (27.5 g) Environment: Indoor use only 32° to 131° F (0° to 55° C) 5 to 95% relative humidity (noncondensing) Agency Compliance: FCC ID: SZV-STM 320U IC: 5713A-STM 320U Notes: · Typical range: 80 ft. · Open area transmission could be farther. Consult factory for more information. · Only for use with EN3 Series relays. · EEP D5-00-01 www.functionaldevices.com/pdf/bulletins/B1877_393233.pdf or scan QR code with your smart phone. WIRELESS DEVICES 158 Functional Devices, Inc. | American Made. American Owned. ENERGY SAVING DEVICES Half-Light® Ballast Controllers Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Half-Light® Ballast Controllers R · Providing independent control for multiple ballast light fixtures from a single existing wall switch or from a lighting controller output, the Half-Light® Ballast Controllers can significantly reduce a building's light output, enabling professional lighting users to cost-effectively enjoy the benefits of lighting control with just a simple toggle of their wall-based light switch. Easy to use and install, Half-Light® Ballast Controllers from Functional Devices are fully compatible with the market's range of popular fluorescent and HID lamps and represent a simple and affordable alternative to the industry's costlier and more complicated dimming systems and components. HALF-LIGHT® BALLAST CONTROLLERS MODEL # HAF2 HAF3 HAF-AI 1 POWER INPUT · 120 / 208-277 Vac · 120 / 208-277 Vac · 24 Vac CONTROL INPUT 0-10 Vdc / 0-5 Vdc RELAYS 1 2 2 1 = UL Listed : UL916 Energy Management ; USA & Canada CONTACTS SPST SPST SPST ENCLOSED · · · NOTES SPEC PAGE 160 160 162 ENERGY SAVING (800) 888-5538 | www.functionaldevices.com 159 R Plug & Play Energy Saving Device for Lighting Up to 50% Energy Savings & Works with All Lighting TWO STAGE & THREE STAGE HALF-LIGHT® BALLAST CONTROLLERS HAF2 Enclosed Independent Control for Multiple Ballast Light Fixtures from One Existing Wall Switch, Two Stage; 120/208-277 Vac Power Input HAF3 Enclosed Independent Control for Multiple Ballast Light Fixtures from One Existing Wall Switch, Three Stage; 120/208-277 Vac Power Input Red 208-277 Vac Wht/Blk Red 208-277 Vac Wht/Blk Relay 2 Blk 120 Vac Wht Neutral or Other Phase Power Input Circuit Relay Org Blk 120 Vac Wht Neutral or Other Phase Power Input Circuit Org Relay 1 R Wht/Red SPECIFICATIONS Input Power: 120 / 208-277 Vac Contact Ratings: 5 Amp Ballast @ 120-277 Vac 5 Amp Incandescent @ 120 Vac Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 3.75 x 1.66 x 1.18 Weight: 0.20 lbs. (HAF2); 0.24 lbs. (HAF3) Wire Length: 6.00 Approvals: UL Listed, UL916, C-UL, CE Approved, RoHS Power Consumption: Refer to www. Half-Light.com for details 160 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 ENERGY SAVING THREE APPLICATIONS MULTIPLE BALLAST LIGHT FIXTURES CLASSROOMS, OFFICES & HIGH BAY FLUORESCENT FIXTURES TWO STAGE HALF-LIGHT® Switch ON activates Ballast 1 Only (50% light) Switch OFF, then ON activates Both Ballasts (Full light) Wall switch can be replaced by switching devices such as contactors, relays, or controllers. THREE STAGE HALF-LIGHT® Switch ON activates Ballast 1 Only Switch OFF, then ON activates Ballast 2 Only Switch OFF, then ON activates Both Ballasts (Full light) White wire Wire to Ballast 2 Wire to Ballast 1 White wire Wire to Ballast 1 Wire to Ballast 2 Incoming 120 Vac or 208-277 Vac controlled by wall switch White Black White/Black White Black or Red * Orange Two Stage Half-Light® Model HAF2 Not Used * Incoming 120 Vac or 208-277 Vac controlled by wall switch White Black White/Red White/Black Three Stage White Half-Light® Black or Red * Model HAF3 Orange Not Used * STEP DIMMING BALLAST CONTROL ELIMINATES DUAL WALL SWITCH CONTROL TWO STAGE HALF-LIGHT® Switch ON 50% Light Switch OFF, then ON Full Light Wall switch can be replaced by switching devices such as contactors, relays, or controllers. Ballast Hot (Typically Black) Ballast Neutral (Typically White) Step Dimming Input (Typically Grey) Wiring in this application note is not characteristic of all step dimming ballasts. Neutral Line Voltage White/Black White Two Stage Half-Light ® Orange Model HAF2 Switched Voltage Input * Not Used * Switching Device Incoming 120 Vac or 208-277 Vac controlled by switching device ALTERNATE FIXTURE CONTROL HIGH BAY FIXTURES IN BOX STORES, GYMNASIUMS, EXHIBITION HALLS & WAREHOUSES Start up and restart times may vary depending on fixture. Lights 2, 4, and 6 controlled by switch only. Half-Light® controls lights 1, 3, and 5. Line Voltage Switching Device Incoming 120 Vac or 208-277 Vac controlled by switching device. Switch must be rated for total lighting load (all xtures on.) Orange * White/ Black Two Stage Half-Light® Not * White Model HAF2 Used Orange * White/ Black Two Stage Half-Light® Not * White Model HAF2 Used TWO STAGE HALF-LIGHT® Switch ON Every Other Light On Switch OFF, then ON All Lights On Wall switch can be replaced by switching devices such as contactors, relays, or controllers. Orange * White/ Black Two Stage Half-Light® Not * White Model HAF2 Used 1 2 3 4 5 6 Neutral * For 120 Vac systems, Black wire is used, Red wire is not used. For 208-277 Vac systems, Red wire is used, Black wire is not used. (800) 888-5538 | www.functionaldevices.com 161 ENERGY SAVING R ENERGY SAVING * White wire Wire to Ballast 2 Wire to Ballast 1 THREE STAGE HALF-LIGHT® BALLAST CONTROLLER WITH ANALOG INPUT HAF-AI Enclosed Independent Control for Multiple Ballast Light Fixtures with Analog Input for Stage Selection (0-10 Vdc / 0-5 Vdc); Three Stage; 24 Vac/dc Power Input Wht/Blu 24Vac/dc Wht/Yel COM Wht/Red + 0-10Vdc / 0-5Vdc Wht/Blk COM Power ON Relay 2 ON Relay 1 ON Relay 2 Brn Brn Relay 1 Org Org Made in USA Meets "Buy American" of ARRA 2009 0-10 VDC CONTROL VOLTAGE 0 2.117Vdc 0-5 VDC * CONTROL VOLTAGE 0 1.058Vdc RELAY 1 STATUS OFF RELAY 2 STATUS OFF HALF-LIGHT® BALLAST CONTROLLER WITH ANALOG INPUT FOR USE WITH 2.745 4.627Vdc 1.373 2.313Vdc ON OFF CONTROLLER OUTPUT R 5.255 7.137Vdc 2.628 3.568Vdc OFF ON 7.765 10.000Vdc 3.883 5.000Vdc ON ON SPECIFICATIONS # Relays & Contact Type: Two (2) SPST-NO Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Relay Status: Green LED On = Power On Red LEDs On = Relays Activated Dimensions: 3.750 x 1.660 x 1.800 Wire Length: 6.00 Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 100mA max. Notes: · Custom programming available for large orders. · For Normally Closed, add -NC to end of model number · Must move jumper for 0-5Vdc.* MULTIPLE BALLAST LIGHT FIXTURES CLASSROOMS, OFFICES & HIGH BAY FLUORESCENT FIXTURES Incoming Voltage for Light Fixture 162 CAN BE USED ON 4 OR 6 BULB FIXTURES Orange Brown Orange Brown Analog-In Half-Light ® Model HAF-AI Wht/Blu 24 Vac/dc Wht/Yel Common Wht/Red Wht/Blk 0-10 Vdc / 0-5 Vdc Controller + Functional Devices, Inc. | American Made. American Owned. INDEX APS53-TC 153 AT4 Series 152 AXG 153 AXGT 153 AXK 153 AXKT 153 AXR 153 CTRL-PS 113 DS8062 153 HAF-AI 162 HAF2 160 HAF3 160 KEYSET 153 MH1000 Series 142 MH1200 Series 142 MH2204-N4 142 MH3100-M1 143 MH3204-N4 143 MH3300 Series 143 MH3500 Series 144 MH3800 Series 144 MH4400 Series 144 MH5500 Series 145 MH5800 Series 145 MHP3903100A100AB10 115 MHP3903100AB10 114 MKL Series 153 MT212 Series 152 MT4 Series 152 PE6000 Series 141 PSB100AB10 124 PSB40AB10 124 PSC100AB10 108 PSC40AB10 108 PSH100A Series 109 PSH100A100A Series 113 PSH100A24DWB10 126 PSH100AB10-EXT2 110 PSH200A 118 PSH200A-LVC 120 PSH200AB10-LVC 123 PSH24DWB10 125 PSH2C2RB10 138 PSH2C2RB10-L 139 PSH2RB10 136 PSH300A 117 PSH300A-LVC 120 PSH300AB10-LVC 122 PSH40A Series 108 PSH40A100A Series 111 PSH40A40A Series 110 PSH40A75A Series 111 PSH40AB10-EXT2 110 PSH500A 116 PSH500A-LVC 119 PSH500AB10-LVC 121 PSH550-UPS (Kit) 136 PSH550-UPS-STAT (Kit) 137 PSH75A Series 109 PSH75A100A Series 112 PSH75A75A Series 112 PSH850-UPS-STAT (Kit) 139 PSM19A24DAS 127 PSM20A12DAS 127 PSM24A24DAS 127 PSM2RB10 137 PSMN01SB10 134 RIBH1CW 12 PSMN01SB4 134 RIBH1S 6 PSMN200A 118 RIBH1SC 7 PSMN24DA 126 RIBH1SM-250 6 PSMN24DAS 126 RIBH2C 5 PSMN24SB10 134 RIBHX24BF 100 PSMN24SB4 134 RIBL12B 45 PSMN2C2RB10 138 RIBL12BM 45 PSMN300A 117 RIBL12SB 45 PSMN40A 124 RIBL12SBM 45 PSMN40A24DS 128 RIBL1C-DC 8 PSMN40AS 124 RIBL24B 46 PSMN500A 116 RIBL24BM 46 PSMS1 135 RIBL24SB 46 PSP24DA 125 RIBL24SBM 46 PSPT2RB10 134 RIBL3C 5 PSPT2RB4 134 RIBL4C 5 PSPW2RB10 134 RIBLB 84 PSPW2RB4 134 RIBLB-2 85 RIB013P 29 RIBLB-4 85 RIB01BDC 60 RIBLB-6 85 RIB01P 26 RIBM013PN 41 RIB01P30 32 RIBM013PNDC 64 RIB01P30-S 32 RIBM01ZNDC 64 RIB01SBCDC 61 RIBM023PN 42 RIB01SBDC 61 RIBM02ZNDC 64 RIB023P 29 RIBM043PN 42 RIB02BDC 60 RIBM043PN-HD 43 RIB02P 27 RIBM12C 15 RIB02P30 32 RIBM12S 15 RIB02SBCDC 61 RIBM2401B 38 RIB02SBDC 61 RIBM2401D 16 RIB043P 30 RIBM2401SB 38 RIB04P 28 RIBM2401SBC 39 RIB12C-FA 56 RIBM2402B 38 RIB12P 31 RIBM2402D 16 RIB12P30 31 RIBM2402SB 38 RIB12S-FA 56 RIBM2402SBC 39 RIB21CDC 60 RIBM243PN 41 RIB2401B 24 RIBM24C 15 RIB2401D 7 RIBM24S 15 RIB2401SB 25 RIBM24ZL 40 RIB2401SBC 26 RIBM24ZN 39 RIB2402B 24 RIBME2401B 53 RIB2402D 7 RIBME2401P 54 RIB2402SB 25 RIBME2401SB 54 RIB2402SBC 26 RIBME2402B 53 RIB2421B 25 RIBME2402P 54 RIB2421C 8 RIBME2402SB 54 RIB2421SB 25 RIBMH1C 16 RIB243P 28 RIBMH1S 17 RIB24C-FA 56 RIBMH1SC 18 RIB24P 31 RIBMH1SM-250 18 RIB24P-FA 57 RIBMH2C 17 RIB24P30 31 RIBMN12C 19 RIB24S-FA 56 RIBMN12C-FA 58 RIB24Z 30 RIBMN12S 19 RIB347P 27 RIBMN12S-FA 58 RIBAN12C 14 RIBMN2401D 21 RIBAN24C 14 RIBMN24C 19 RIBD01BDC 62 RIBMN24C-4T 20 RIBD01BDC-DOB 63 RIBMN24C-FA 58 RIBD02BDC 62 RIBMN24Q2C 88 RIBD02BDC-DOB 63 RIBMN24Q3C 88 RIBD2421C 9 RIBMN24Q4C 89 RIBH1C 4 RIBMN24Q4C-PX 89 (800) 888-5538 | www.functionaldevices.com RIBMN24S 19 RIBMN24S-4T 20 RIBMN24S-FA 58 RIBMN24S-J 20 RIBMN24ZL 40 RIBMNA1D0 90 RIBMNH1C 21 RIBMNH1S 22 RIBMNLB 84 RIBMNLB-1 87 RIBMNLB-2 85 RIBMNLB-2NO 86 RIBMNLB-4 85 RIBMNLB-4NO 86 RIBMNLB-6 85 RIBMNLB-6NO 86 RIBMNU1C 21 RIBMNU1S 22 RIBMNW24B-BCAI 75 RIBMNW24B-MBAI 82 RIBMNWD12-BC 78 RIBMNWD12-BCDI 77 RIBMNWX2401B-BC 73 RIBMNWX2401SB-LN 68 RIBMNWX2402B-BC 74 RIBMNWX2402SB-LN 69 RIBMU1C 16 RIBMU1S 17 RIBMU1SC 18 RIBMU1SM-250 18 RIBMU2C 17 RIBMW24B-44-BC 79 RIBMW24SB-LNAI 70 RIBMW24SB-LNT2 71 RIBMW24SB-LNT3 71 RIBMX24BA 105 RIBMX24BF 105 RIBMX24BV 105 RIBMX24SBA 105 RIBMX24SBF 105 RIBMX24SBV 105 RIBMXRA 99 RIBMXRF 99 RIBMXV 99 RIBT2401B 33 RIBT2401D 13 RIBT2401SB 34 RIBT2401SBC 34 RIBT2402B 33 RIBT2402SB 34 RIBT2402SBC 34 RIBT242B 36 RIBT243B 36 RIBT243P 37 RIBT24B 33 RIBT24B-FA 57 RIBT24P 36 RIBT24SB 33 RIBT24Z 37 RIBTD2401B 35 RIBTE01B 49 RIBTE01P 52 RIBTE01P-S 53 RIBTE01SB 50 RIBTE02B 49 RIBTE02P 52 163 INDEX INDEX INDEX RIBTE02P-S 53 RIBTE02SB 51 RIBTE24B 48 RIBTE24P 51 RIBTE24SB 50 RIBTELC 48 RIBTELS 48 RIBTH1C 11 RIBTH1S 12 RIBTH1SC 13 RIBTH2C 11 RIBTU1C 11 RIBTU1S 12 RIBTU1SC 13 RIBTU2C 11 RIBTW2401B-BC 72 RIBTW2401B-LN 66 RIBTW2401B-WIUI-N4 81 RIBTW2401SB-LN 67 RIBTW2402B-BC 72 RIBTW2402B-LN 66 RIBTW2402SB-LN 67 RIBTW24B-BCAI 75 RIBTW24B-BCAO 76 RIBTW24B-MBAI 82 RIBTW24B-WI-N4 80 RIBTW24SB-LNAI 70 RIBTW24SB-LNT2 71 RIBTW24SB-LNT3 71 RIBTWX2401B-BC 73 RIBTWX2401SB-LN 68 RIBTWX2402B-BC 74 RIBTWX2402SB-LN 69 RIBU1C 4 RIBU1CW 12 RIBU1S 6 RIBU1SC 7 RIBU1SM-250 6 RIBU2C 5 RIBU2S2 10 RIBU2SC 10 RIBW01B-EN3 156 RIBW01C-EN3 157 RIBW02C-EN3 157 RIBW208B-EN3 156 RIBW240B-EN3 156 RIBW24B-EN3 156 RIBW277B-EN3 156 RIBX243PA 104 RIBX243PF 104 RIBX243PV 104 RIBX24BA 103 RIBX24BF 103 RIBX24BV 103 RIBX24SBA 103 RIBX24SBF 103 RIBX24SBV 103 RIBXA 98 RIBXF 98 RIBXG21A 95 RIBXG21F 95 RIBXG21TA 95 RIBXG21TF 95 RIBXG420-100 97 RIBXG420-20 97 RIBXG420-50 97 164 RIBXGA RIBXGA-SCAL RIBXGF RIBXGFL RIBXGHA RIBXGHF RIBXGHTA RIBXGHTF RIBXGTA RIBXGTA-SCAL RIBXGTF RIBXGTFL RIBXGTV10 RIBXJA RIBXJF RIBXK420-100 RIBXK420-20 RIBXK420-50 RIBXKA RIBXKF RIBXKTA RIBXKTF RIBXKTV5-10 RIBXKTV5-100 RIBXKTV5-20 RIBXKTV5-50 RIBXLCA RIBXLCEA RIBXLCEV RIBXLCF RIBXLCJA RIBXLCJF RIBXLCRA RIBXLCRF RIBXLCV RIBXLSA RIBXLSEA RIBXLSEV RIBXLSF RIBXLSJA RIBXLSJF RIBXLSRA RIBXLSRF RIBXLSV RIBXRA RIBXRF RIBXV SIB02S SIB04S SIB05S SIBLS SP3303 SP3304 SP3803L SP3803S SP3804L SP3804S SP4403L SP4404L SP5503L SP5504L SP5803L SP5804L TR100VA001 TR100VA001US TR100VA002 94 TR100VA002-20 131 94 TR100VA002US 130 94 TR100VA004 131 94 TR100VA005 131 93 TR100VA008 131 93 TR100VA009 131 93 TR100VA009US 130 93 TR100VA015 131 94 TR150VA001 131 94 TR150VA002 131 94 TR150VA008 131 94 TR175VA001 131 96 TR175VA002 131 99 TR175VA003 131 99 TR20VA001 131 96 TR20VA002 131 96 TR20VA003 131 96 TR20VA004 131 93 TR20VA007 131 93 TR240VA001 131 93 TR300VA002 131 93 TR375VA001 131 95 TR40VA001 131 95 TR40VA001US 130 95 TR40VA002 131 95 TR40VA002US 130 101 TR40VA003 131 101 TR40VA004 131 101 TR40VA013 131 101 TR40VA015 131 101 TR40VA022 131 101 TR40VA040 131 101 TR50VA001 131 101 TR50VA001US 130 101 TR50VA002 131 102 TR50VA003 131 102 TR50VA004 131 102 TR50VA005 131 102 TR50VA005US 130 102 TR50VA006 131 102 TR50VA007 131 102 TR50VA008 131 102 TR50VA009 131 102 TR50VA014 131 98 TR50VA015 131 98 TR50VA016 131 98 TR50VA017 131 135 TR50VA018 131 135 TR50VA019 131 135 TR50VA022US 130 135 TR75VA001 131 148 TR75VA002 131 148 TR75VA003 131 149 TR75VA004 131 148 TR75VA005 131 149 TR75VA007 131 149 TS-AN 153 150 WDWS-EN3 158 150 WWS-EN3 157 150 151 151 151 131 130 131 Functional Devices, Inc. | American Made. American Owned.Adobe InDesign CC 2015 (Macintosh) Adobe PDF Library 15.0