Anker Innovations Limited T8200 Video Doorbell 2K (Wired) 2AOKB-T8200 2AOKBT8200 t8200
REPORT No.SZ19030188W05 TEST REPORT APPLICANT : Anker Innovations Limited PRODUCT NAME : Video Doorbell 2K (Wired) MODEL NAME : T8200 BRAND NAME : eufy Security FCC ID : 2AOKB-T8200 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2019-03-14 TEST DATE : 2019-03-20 to 2019-04-01 ISSUE DATE : 2019-04-25 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Peng Huarui ( Supervisor ) NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 1 of 69 REPORT No.SZ19030188W05 DIRECTORY 1. Technical Information 4 1.1. Applicant and Manufacturer Information 4 1.2. Equipment Under Test (EUT) Description 4 1.3. Test Standards and Results 6 1.4. Environmental Conditions 6 2. 47 CFR Part 15C Requirements 7 2.1. Antenna requirement 7 2.2. Duty Cycle Of Test Signal 7 2.3. Maximum Peak and Average Conducted Output Power 11 2.4. Bandwidth 16 2.5. Conducted Spurious Emissions and Band Edge23 2.6. Power spectral density (PSD) 33 2.7. Conducted Emission40 2.8. Restricted Frequency Bands 44 2.9. Radiated Emission53 Annex A Test Uncertainty 66 Annex B Testing Laboratory Information 67 MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 2 of 69 Version 1.0 REPORT No.SZ19030188W05 Change History Date 2019-04-25 Reason for change First edition MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 3 of 69 1. Technical Information REPORT No.SZ19030188W05 Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Applicant Address: Manufacturer: Manufacturer Address: Anker Innovations Limited Room 1318-19,Hollywood Plaza,610 Nathan Road, Mongkok, Kowloon, Hong Kong Anker Innovations Limited Room 1318-19,Hollywood Plaza,610 Nathan Road, Mongkok, Kowloon, Hong Kong 1.2. Equipment Under Test (EUT) Description Product Name: Serial No: Hardware Version: Software Version: Equipment type: Modulation Type: Operating Frequency Range: Channel Number: Antenna Type: Antenna Gain: Video Doorbell 2K (Wired) (N/A, marked #1 by test site) V03 V12 WLAN2.4G DSSS, OFDM 802.11b/g/ n(HT20): 2.412GHz - 2.462GHz 802.11b/g/ n(HT20): 11 PIFA Antenna Ant0: 0 dBi; Ant1: 0 dBi MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 4 of 69 REPORT No.SZ19030188W05 Note 1: The EUT has two antennas but not support MIMO function for each modulation mode. Both of the two antennas were tested separately, we only recorded the worst test result(Ant0) in this report. Modulation Mode: TX Function Relationship between the two output signals 802.11b 1TX Uncorrelated 802.11g 1TX Uncorrelated 802.11n 1TX Uncorrelated Note2: The EUT is operating at 2.4GHz ISM; it supports 802.11b, 802.11g, 802.11n and they are all tested in this report. For 802.11b/g/n(HT20) (2.4GHz band), the frequencies allocated is F (MHz) =2412+5*(n-1) (1<=n<=11). The lowest, middle, highest channel numbers of the EUT used and tested in this report are separately 1 (2412MHz), 6 (2437MHz) and 11 (2462MHz). Note 3: The EUT connected to the serial port of the computer with a serial communication cable, we use the dedicated software to control the EUT continuous transmission. Note 4: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 5 of 69 1.3. Test Standards and Results REPORT No.SZ19030188W05 The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT FCC ID Certification: No Identity Document Title 1 47 CFR Part 15 Radio Frequency Devices Test detailed items/section required by FCC rules and results are as below: No. Section Description Test Date Test Engineer 1 15.203 Antenna Requirement N/A N/A 2 N/A Duty Cycle Of Test Signal Mar 26, 2019 Zhang Guofeng 3 15.247(b) Maximum Peak and Average Conducted Output Power Mar 26, 2019 Zhang Guofeng Result PASS PASS PASS 4 15.247(a) Bandwidth Mar 26, 2019 Zhang Guofeng PASS 5 15.247(d) Conducted Spurious Emission and Band Edge Mar 26, 2019 Zhang Guofeng PASS 6 15.247(e) Power spectral density (PSD) Mar 26, 2019 Zhang Guofeng PASS 7 15.207 Conducted Emission Mar 20, 2019 Wu Zhongwen PASS 8 15.247(d) Restricted Frequency Bands Mar 23, 2019 Wu Zhongwen PASS 9 15.209, 15.247(d) Radiated Emission Apr 01, 2019 Wu Zhongwen PASS Note1: The tests were performed according to the method of measurements prescribed in ANSIC63.10-2013 and KDB558074 D01 v05r02. Note2: The path loss during the RF test is calibrated to correct the results by the offset setting in the test equipments. The ref offset 11.5dB contains two parts that cable loss 1.5dB and Attenuator 10dB. 1.4. Environmental Conditions During the measurement, the environmental conditions were within the listed ranges: Temperature (°C): Relative Humidity (%): Atmospheric Pressure (kPa): 15 - 35 30 -60 86-106 MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 6 of 69 REPORT No.SZ19030188W05 2. 47 CFR Part 15C Requirements 2.1. Antenna requirement 2.1.1. Applicable Standard According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. 2.1.2. Result: Compliant The EUT has a permanently and irreplaceable attached antenna. Please refer to the EUT internal photos. 2.2. Duty Cycle Of Test Signal 2.2.1. Requirement Preferably, all measurements of maximum conducted (average) output power will be performed with the EUT transmitting continuously (i.e., with a duty cycle of greater than or equal to 98%). When continuous operation cannot be realized, then the use of sweep triggering/signal gating techniques can be used to ensure that measurements are made only during transmissions at the maximum power control level. Such sweep triggering/signal gating techniques will require knowledge of the minimum transmission duration (T) over which the transmitter is on and is transmitting at its maximum power control level for the tested mode of operation. Sweep triggering/signal gating techniques can then be used if the measurement/sweep time of the analyzer can be set such that it does not exceed T at any time that data are being acquired (i.e., no transmitter OFF-time is to be considered). When continuous transmission cannot be achieved and sweep triggering/signal gating cannot be implemented, alternative procedures are provided that can be used to measure the average power; however, they will require an additional measurement of the transmitter duty cycle (D). Within this subclause, the duty cycle refers to the fraction of time over which the transmitter is ON and is transmitting at its maximum power control level. The duty cycle is considered to be constant if variations are less than ±2%; otherwise, the duty cycle is considered to be nonconstant. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 7 of 69 2.2.2. Test Description A. Test Set: REPORT No.SZ19030188W05 ANSI C63.10 2013 Clause 11.6 was used in order to prove compliance. B. Equipments List: Please refer ANNEX B(4). 2.2.3. Test Result A. Test Verdict: Test Mode 802.11b 802.11g 802.11n(HT20) Duty Cycle (%) (D) 98.97 93.44 92.33 Duty Factor (10*lg[1/D]) 0.05 0.29 0.35 MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 8 of 69 B. Test Plots REPORT No.SZ19030188W05 (Channel 1, 2412MHz, 802.11b) (Channel 1, 2412MHz, 802.11g) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 9 of 69 REPORT No.SZ19030188W05 (Channel 1, 2412MHz, 802.11 n(HT20)) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 10 of 69 REPORT No.SZ19030188W05 2.3. Maximum Peak and Average Conducted Output Power 2.3.1. Requirement According to FCC section 15.247(b)(3), For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: The maximum peak conducted output power of the intentional radiator shall not exceed1 Watt. 2.3.2. Test Description The measured output power was calculated by the reading of the USB Wideband Power Sensor and calibration. A. Test Setup: Attenuator The EUT (Equipment under the test) which is coupled to the USB Wideband Power Sensor; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. B. Equipments List: Please refer ANNEX B(4). MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 11 of 69 REPORT No.SZ19030188W05 2.3.3. Test Result Maximum Peak Conducted Output Power (Ant 0) 802.11b Test Mode Channel Frequency (MHz) Measured Output Peak Power dBm W 1 2412 24.15 0.260 6 2437 24.16 0.261 11 2462 24.34 0.272 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11g Test mode Channel Frequency (MHz) 1 2412 6 2437 11 2462 Measured Output Peak Power dBm W 28.21 0.662 24.24 0.265 28.48 0.705 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11n(HT20) Test mode Channel Frequency (MHz) 1 2412 6 2437 11 2462 Measured Output Peak Power dBm W 28.01 0.632 28.12 0.649 28.23 0.665 Limit dBm W 30 1 Verdict PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 12 of 69 REPORT No.SZ19030188W05 Maximum Peak Conducted Output Power (Ant 1) 802.11b Test Mode Channel Frequency (MHz) Measured Output Peak Power dBm W 1 2412 18.87 0.077 6 2437 19.02 0.080 11 2462 19.13 0.082 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11g Test mode Channel Frequency (MHz) 1 2412 6 2437 11 2462 Measured Output Peak Power dBm W 24.11 0.258 21.30 0.135 23.89 0.245 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11n(HT20) Test mode Channel Frequency (MHz) 1 2412 6 2437 11 2462 Measured Output Peak Power dBm W 23.63 0.231 23.72 0.236 23.77 0.238 Limit dBm W 30 1 Verdict PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 13 of 69 REPORT No.SZ19030188W05 Maximum Average Conducted Output Power (Ant0) 802.11b Test Mode Channel Frequency (MHz) Measured dBm Average Power Duty factor Calculated dBm W 1 2412 21.12 21.17 0.131 6 2437 21.24 21.29 0.135 11 2462 21.27 21.32 0.136 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11g Test mode Channel Frequency (MHz) 1 2412 6 2437 11 2462 Measured dBm 21.58 21.62 21.63 Average Power Duty factor Calculated dBm W 21.87 0.154 21.91 0.155 21.92 0.156 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11n(HT20) Test mode Channel Frequency (MHz) 1 2412 6 2437 11 2462 Measured dBm 21.64 21.73 21.71 Average Power Duty factor Calculated dBm W 21.99 0.158 22.08 0.161 22.06 0.161 Limit dBm W 30 1 Verdict PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 14 of 69 REPORT No.SZ19030188W05 Maximum Average Conducted Output Power (Ant1) 802.11b Test Mode Channel Frequency (MHz) Measured dBm Average Power Duty factor Calculated dBm W 1 2412 17.41 17.46 0.056 6 2437 17.46 17.51 0.056 11 2462 17.55 17.60 0.058 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11g Test mode Channel Frequency (MHz) 1 2412 6 2437 11 2462 Measured dBm 19.47 18.30 19.58 Average Power Duty factor Calculated dBm W 19.76 0.095 18.59 0.072 19.87 0.097 Limit dBm W 30 1 Verdict PASS PASS PASS 802.11n(HT20) Test mode Channel Frequency (MHz) 1 2412 6 2437 11 2462 Measured dBm 19.37 19.62 19.58 Average Power Duty factor Calculated dBm W 19.72 0.094 19.97 0.099 19.93 0.098 Limit dBm W 30 1 Verdict PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 15 of 69 2.4. Bandwidth REPORT No.SZ19030188W05 2.4.1. Requirement According to FCC section 15.247(a) (2), Systems using digital modulation techniques may operate in the 902 - 928 MHz, 2400 - 2483.5 MHz, and 5725 - 5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz. 2.4.2. Test Description A. Test Set: The EUT is coupled to the Spectrum Analyzer; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) = 100 kHz. In order to make an accurate measurement, set the span greater than RBW. KDB 558074 Section 8.2 was used in order to prove compliance. B. Equipments List: Please refer ANNEX B(4). MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 16 of 69 2.4.3. Test Result 802.11b Test mode A. Test Verdict: Channel 1 6 11 Frequency (MHz) 2412 2437 2462 B. Test Plots REPORT No.SZ19030188W05 6 dB Bandwidth (MHz) 8.063 8.046 7.574 Limits(kHz) 500 500 500 Result PASS PASS PASS (Channel 1, 2412MHz, 802.11b) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 17 of 69 REPORT No.SZ19030188W05 (Channel 6, 2437 MHz, 802.11b) (Channel 11, 2462MHz, 802.11b) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 18 of 69 802.11g Test mode A. Test Verdict: Channel Frequency (MHz) 1 2412 6 2437 11 2462 B. Test Plots: REPORT No.SZ19030188W05 6 dB Bandwidth (MHz) 16.41 16.43 16.42 Limits (kHz) 500 500 500 Result PASS PASS PASS (Channel 1, 2412MHz, 802.11g) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 19 of 69 REPORT No.SZ19030188W05 (Channel 6, 2437MHz, 802.11g) (Channel 11, 2462MHz, 802.11g) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 20 of 69 802.11n(HT20) Test mode A. Test Verdict: Channel Frequency (MHz) 1 2412 6 2437 11 2462 B. Test Plots: REPORT No.SZ19030188W05 6 dB Bandwidth (MHz) 17.64 17.63 17.63 Limits (kHz) 500 500 500 Result PASS PASS PASS (Channel 1, 2412MHz, 802.11n(HT20)) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 21 of 69 REPORT No.SZ19030188W05 (Channel 6, 2437MHz, 802.11n(HT20)) (Channel 11, 2462MHz, 802.11n(HT20)) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 22 of 69 REPORT No.SZ19030188W05 2.5. Conducted Spurious Emissions and Band Edge 2.5.1. Requirement According to FCC section 15.247(c), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. 2.5.2. Test Description A. Test Set: The EUT is coupled to the Spectrum Analyzer; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) = 100 kHz. In order to make an accurate measurement, set the span greater than RBW. KDB 558074 Section 8.5 and 8.7 was used in order to prove compliance. B. Equipments List: Please refer ANNEX B(4). MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 23 of 69 REPORT No.SZ19030188W05 2.5.3. Test Result 802.11b Test mode A. Test Verdict: Channel 1 6 11 Frequency (MHz) 2412 2437 2462 Measured Max. Out of Band Emission (dBm) -42.13 -42.33 -40.85 B. Test Plots: Limit (dBm) Carrier Calculated Level -20dBc Limit 12.52 -7.48 11.60 -8.40 13.41 -6.59 Verdict PASS PASS PASS (Channel = 1, 30MHz to 25GHz) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 24 of 69 REPORT No.SZ19030188W05 (Band Edge, Channel = 1) (Channel = 6, 30MHz to 25GHz) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 25 of 69 REPORT No.SZ19030188W05 (Channel = 11, 30MHz to 25GHz) (Band Edge, Channel = 11) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 26 of 69 REPORT No.SZ19030188W05 802.11g Test mode A. Test Verdict: Channel Frequency (MHz) 1 6 11 B. Test Plots: 2412 2437 2462 Measured Max. Out of Band Emission (dBm) -49.86 -50.76 -50.31 Limit (dBm) Carrier Calculated Level -20dBc Limit 10.48 -9.52 7.77 -12.23 8.38 -11.62 Verdict PASS PASS PASS (Channel = 1, 30MHz to 25GHz) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 27 of 69 REPORT No.SZ19030188W05 (Band Edge, Channel = 1) (Channel = 6, 30MHz to 25GHz) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 28 of 69 REPORT No.SZ19030188W05 (Channel = 11, 30MHz to 25GHz) (Band Edge, Channel = 11) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 29 of 69 REPORT No.SZ19030188W05 802.11n(HT20) Test mode A. Test Verdict: Channel Frequency (MHz) 1 6 11 B. Test Plots: 2412 2437 2462 Measured Max. Out of Band Emission (dBm) -51.29 -50.07 -51.67 Limit (dBm) Carrier Calculated Level -20dBc Limit 9.99 -10.01 8.10 -11.90 7.45 -12.55 Verdict PASS PASS PASS (Channel = 1, 30MHz to 25GHz) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 30 of 69 REPORT No.SZ19030188W05 (Band Edge, Channel = 1) (Channel = 6, 30MHz to 25GHz) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 31 of 69 REPORT No.SZ19030188W05 (Channel = 11, 30MHz to 25GHz) (Band Edge, Channel = 11) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 32 of 69 2.6. Power spectral density (PSD) REPORT No.SZ19030188W05 2.6.1. Requirement For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral density shall be determined in accordance with the provisions of paragraph (b) of this section. The same method of determining the conducted output power shall be used to determine the power spectral density. 2.6.2. Test Description A. Test procedure The measured power spectral density was calculated by the reading of the spectrum analyzer and calibration. Following is the test procedure for PSD test: a) Set analyzer center frequency to channel center frequency. b) Set the span to 1.5 times DTS c) Set the RBW to 3 kHz d) Set the VBW to 10 kHz e) Detector = peak. f) Sweep time = auto couple. g) Trace mode = max hold. h) Allow trace to fully stabilize. i) Use the peak marker function to determine the maximum amplitude level within the RBW. B. Test Set: The EUT is coupled to the Spectrum Analyzer; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. KDB 558074 Section 8.4 was used in order to prove compliance. C. Equipments List: Please refer ANNEX B(4). MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 33 of 69 REPORT No.SZ19030188W05 2.6.3. Test Result 802.11b Test mode A. Test Verdict: Channel 1 6 11 Spectral power density (dBm/3kHz) Frequency (MHz) Measured PSD (dBm/3kHz) 2412 0.54 2437 -0.15 2462 0.19 Limit (dBm/3kHz) 8 8 8 B. Test Plots: Verdict PASS PASS PASS (Channel = 1, 802.11b) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 34 of 69 REPORT No.SZ19030188W05 (Channel = 6, 802.11b) (Channel = 11, 802.11b) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 35 of 69 REPORT No.SZ19030188W05 802.11g Test mode A. Test Verdict: Channel 1 6 11 Spectral power density (dBm/3kHz) Frequency (MHz) Measured PSD (dBm/3kHz) 2412 -2.12 2437 -3.21 2462 -2.12 B. Test Plots: Limit (dBm/3kHz) 8 8 8 Verdict PASS PASS PASS (Channel = 1, 802.11g) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 36 of 69 REPORT No.SZ19030188W05 (Channel = 6, 802.11g) (Channel = 11, 802.11g) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 37 of 69 REPORT No.SZ19030188W05 802.11n(HT20) Test mode A. Test Verdict: Channel 1 6 11 Frequency (MHz) 2412 2437 2462 Spectral power density (dBm/3kHz) Measured PSD (dBm/3kHz) -0.77 -2.88 -2.40 B. Test Plots: Limit (dBm/3kHz) 8 8 8 Verdict PASS PASS PASS (Channel = 1, 802.11n(HT20)) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 38 of 69 REPORT No.SZ19030188W05 (Channel = 6, 802.11n(HT20)) (Channel = 11, 802.11n(HT20)) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 39 of 69 2.7. Conducted Emission REPORT No.SZ19030188W05 2.7.1. Requirement According to FCC section 15.207, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency range Conducted Limit (dBµV) (MHz) Quai-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 NOTE: (a) The lower limit shall apply at the band edges. (b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. 2.7.2. Test Description A. Test Setup: The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10 2013. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 40 of 69 REPORT No.SZ19030188W05 B. Equipments List: Please refer ANNEX B(4). 2.7.3. Test Result The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test setup: Test Mode: EUT+ADAPTER + WIFI TX Test Voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 41 of 69 B. Test Plots: REPORT No.SZ19030188W05 (L Phase) NO. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.3030 26.39 21.82 2 0.7800 26.70 22.02 3 1.2740 25.42 20.27 4 4.0616 14.23 9.29 5 9.2345 12.73 8.04 6 19.6641 27.02 14.28 Limit (dBµV) Quai-peak 60.16 56.00 56.00 56.00 60.00 60.00 Average 50.16 46.00 46.00 46.00 50.00 50.00 Power-line Line Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 42 of 69 REPORT No.SZ19030188W05 (N Phase) NO. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1678 46.01 25.73 2 0.2128 41.89 24.39 3 0.2578 39.89 23.70 4 0.5141 29.47 20.95 5 1.1084 29.13 20.84 6 25.8982 24.71 13.12 Limit (dBµV) Quai-peak 65.07 63.09 61.50 56.00 56.00 60.00 Average 55.07 53.09 51.50 46.00 46.00 50.00 Power-line Neutral Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 43 of 69 2.8. Restricted Frequency Bands REPORT No.SZ19030188W05 2.8.1. Requirement According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a). 2.8.2. Test Description A. Test Setup The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. KDB 558074 Section 8.6 and 8.7 was used in order to prove compliance. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 44 of 69 REPORT No.SZ19030188W05 B. Equipments List: Please refer ANNEX B(4). 2.8.3. Test Result The lowest and highest channels are tested to verify Restricted Frequency Bands. The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m Note: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (vertical) was recorded in this test report. 802.11b Test mode A. Test Verdict: Receiver Max. Channel Frequency (MHz) Detector Reading UR AT (dB) AFactor (dB@3m) Emission E Limit (dBµV/m) Verdict PK/ AV (dBuV) (dBµV/m) 1 2372.91 PK 54.28 -29.67 32.56 57.17 74 PASS 1 2390.00 AV 41.87 -29.67 32.56 44.76 54 PASS 11 2485.29 PK 55.50 -29.67 32.56 58.39 74 PASS 11 2483.50 AV 42.77 -29.67 32.56 45.66 54 PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 45 of 69 B. Test Plots: REPORT No.SZ19030188W05 (Channel = 1 PEAK, 802.11b) (Channel = 1 AVG, 802.11b) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 46 of 69 REPORT No.SZ19030188W05 (Channel = 11 PEAK, 802.11b) (Channel = 11 AVG, 802.11b) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 47 of 69 REPORT No.SZ19030188W05 802.11g Test mode A. Test Verdict: Channel Frequency (MHz) Detector PK/ AV Receiver Reading UR (dBuV) AT (dB) AFactor (dB@3m) Max. Emission E (dBµV/m) Limit (dBµV/m) Verdict 1 2390.00 PK 63.60 -29.67 32.56 66.49 74 PASS 1 2390.00 AV 45.48 -29.67 32.56 48.37 54 PASS 11 2483.50 PK 66.13 -29.67 32.56 69.02 74 PASS 11 2483.50 AV 47.12 -29.67 32.56 50.01 54 PASS B. Test Plots: (Channel = 1 PEAK, 802.11g) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 48 of 69 REPORT No.SZ19030188W05 (Channel = 1 AVG, 802.11g) (Channel = 11 PEAK, 802.11g) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 49 of 69 REPORT No.SZ19030188W05 (Channel = 11 AVG, 802.11g) 802.11 n(HT20) Test mode A. Test Verdict: Receiver Max. Channel Frequency (MHz) Detector Reading UR AT (dB) AFactor (dB@3m) Emission E Limit (dBµV/m) Verdict PK/ AV (dBuV) (dBµV/m) 1 2390.00 PK 59.19 -29.67 32.56 62.08 74 PASS 1 2390.00 AV 40.46 -29.67 32.56 43.35 54 PASS 11 2483.50 PK 49.60 -29.67 32.56 52.49 74 PASS 11 2483.50 AV 37.12 -29.67 32.56 40.01 54 PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 50 of 69 B. Test Plots: REPORT No.SZ19030188W05 (Channel = 1 PEAK, 802.11n(HT20)) (Channel = 1 AVG, 802.11n(HT20)) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 51 of 69 REPORT No.SZ19030188W05 (Channel = 11 PEAK, 802.11n(HT20)) (Channel = 11 AVG, 802.11n(HT20)) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 52 of 69 2.9. Radiated Emission REPORT No.SZ19030188W05 2.9.1. Requirement According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) 0.009 - 0.490 0.490 - 1.705 1.705 - 30.0 30 - 88 88 - 216 216 - 960 Above 960 Field Strength (µV/m) 2400/F(kHz) 24000/F(kHz) 30 100 150 200 500 Measurement Distance (m) 300 30 30 3 3 3 3 Note: For Above 1000MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and 74dBuV/m@3m (PK) In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), also should comply with the radiated emission limits specified in Section 15.209(a)(above table) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 53 of 69 2.9.2. Test Description A. Test Setup: 1) For radiated emissions from 9kHz to 30MHz REPORT No.SZ19030188W05 2) For radiated emissions from 30MHz to1GHz MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 54 of 69 3) For radiated emissions above 1GHz REPORT No.SZ19030188W05 The RF absorbing material used on the reference ground plane and on the turntable have a maximum height (thickness) of 30 cm (12 in) and have a minimum-rated attenuation of 20 dB at all frequencies from 1 GHz to 18 GHz. Test site have a minimum area of the ground plane covered with RF absorbing material as specified in Figure 6 of ANSI C63.4: 2014. The test site semi-anechoic chamber has met the requirement of NSA tolerance 4dB according to the standards: ANSI C63.10 (2013). For radiated emissions below or equal to 1GHz, The EUT was set-up on insulator 80cm above the Ground Plane, For radiated emissions above 1GHz, The EUT was set-up on insulator 150cm above the Ground Plane. The set-up and test methods were according to ANSI C63.10 For the radiated emission test above 1GHz: Place the measurement antenna away from each area of the EUT determined to be a source of emissions at the specified measurement distance, while keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. The measurement antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission source for receiving the maximum signal. The final measurement antenna elevation shall be that which maximizes the emissions. The measurement antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 55 of 69 REPORT No.SZ19030188W05 For the Test Antenna: (a) In the frequency range of 9kHz to 30MHz, magnetic field is measured with Loop Test Antenna. The Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of the Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna rotates about its vertical axis for maximum response at each azimuth about the EUT. (b) In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test Antenna (above 1GHz) are used. Place the test antenna at 3m away from area of the EUT, while keeping the test antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. The test antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission source for receiving the maximum signal. The final test antenna elevation shall be that which maximizes the emissions. The test antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. The emission levels at both horizontal and vertical polarizations should be tested. A. Equipments List: Please refere ANNEX B(4). 2.9.3. Test Result According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak limit, it is unnecessary to perform an quasi-peak measurement. The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9 kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 25GHz to 40GHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 56 of 69 802.11b Test mode Plots for Channel = 1 REPORT No.SZ19030188W05 Fre. (MHz) 100.413 242.453 475.544 2375.910 4746.718 12331.515 Pk (dBV/m) 28.71 31.19 32.30 52.51 45.72 47.87 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 25GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 105.269 325.006 575.094 2515.486 9072.740 18282.851 Pk (dBV/m) 29.36 31.35 34.20 47.03 45.35 48.80 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 25GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 57 of 69 Plot for Channel = 6 REPORT No.SZ19030188W05 Fre. (MHz) 100.413 249.737 575.094 1804.802 4290.489 12905.874 Pk (dBV/m) 28.82 32.43 37.27 45.53 44.79 47.09 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 25GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 95.557 325.006 624.869 2355.422 5732.497 10918.021 Pk (dBV/m) 28.56 31.29 36.34 50.43 46.17 46.76 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 25GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 58 of 69 Plot for Channel = 11 REPORT No.SZ19030188W05 Fre. (MHz) 119.837 249.737 475.544 2339.416 5638.807 12144.135 Pk (dBV/m) 30.18 30.13 35.77 47.46 45.74 46.96 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 25GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 100.413 325.006 575.094 1775.990 5655.101 12148.209 Pk (dBV/m) 28.29 32.23 33.87 45.56 46.53 46.82 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 25GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 59 of 69 802.11g Test mode Plots for Channel = 1 REPORT No.SZ19030188W05 Fre. (MHz) 100.413 325.006 575.094 2463.625 5655.101 11732.715 Pk (dBV/m) 28.62 34.00 38.09 50.58 46.18 46.96 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 25GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 105.269 475.544 624.869 2105.082 7915.876 12592.217 Pk (dBV/m) 28.09 34.55 36.94 46.66 46.06 48.11 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 25GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 60 of 69 Plot for Channel = 6 REPORT No.SZ19030188W05 Fre. (MHz) 118.623 249.737 575.094 2462.985 5748.791 12535.188 Pk (dBV/m) 29.84 30.39 37.65 49.98 46.44 47.33 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 25GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 95.557 325.006 575.094 2463.625 3858.702 10233.679 Pk (dBV/m) 27.88 32.02 33.81 50.14 45.98 46.44 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 25GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 61 of 69 Plot for Channel = 11 REPORT No.SZ19030188W05 Fre. (MHz) 100.413 249.737 575.094 2025.690 4526.750 10307.001 Pk (dBV/m) 29.61 33.71 38.23 45.70 44.62 46.30 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 25GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 95.557 325.006 624.869 2464.906 5748.791 12131.915 Pk (dBV/m) 28.93 30.52 36.38 47.83 46.30 46.54 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 25GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 62 of 69 802.11n(HT20) Test mode Plots for Channel = 1 REPORT No.SZ19030188W05 Fre. (MHz) 249.737 479.186 1597.359 2384.000 2516.126 8991.271 Pk (dBV/m) 33.11 33.09 47.29 58.19 53.88 47.93 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A 40.39 74.00 N/A 54.00 N/A 36.67 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 25GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 105.269 325.006 575.094 2537.255 12172.650 20449.936 Pk (dBV/m) 28.77 33.27 33.38 51.27 46.02 49.44 QP AV Limit-PK Limit-QP (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 46.00 N/A N/A N/A 46.00 N/A N/A 74.00 N/A N/A N/A 74.00 N/A N/A N/A 74.00 N/A (Antenna Vertical, 30MHz to 25GHz) Limit-AV (dBV/m) N/A N/A N/A 54.00 54.00 54.00 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 63 of 69 Plot for Channel = 6 REPORT No.SZ19030188W05 Fre. (MHz) 100.413 249.737 624.869 2390.636 5708.056 12881.433 Pk (dBV/m) 28.56 30.81 36.50 49.87 45.58 46.51 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 25GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 95.557 240.025 475.544 2525.730 5675.468 18246.190 Pk (dBV/m) 28.53 26.77 33.79 52.82 46.17 48.54 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 25GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 64 of 69 Plot for Channel = 11 REPORT No.SZ19030188W05 Fre. (MHz) 118.623 247.309 475.544 2524.800 5659.174 13997.563 Pk (dBV/m) 28.92 31.34 32.54 61.41 47.08 47.22 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A 38.99 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 25GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 100.413 299.512 624.869 2535.334 8416.912 18233.970 Pk (dBV/m) 29.27 30.80 37.15 52.43 48.02 49.98 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A N/A N/A 46.00 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 25GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 65 of 69 Annex A Test Uncertainty REPORT No.SZ19030188W05 Where relevant, the following measurement uncertainty levels have been estimated for test performed on the EUT as specified in CISPR 16-1-2: Test items Uncertainty Peak Output Power ±2.22dB Power spectral density (PSD) ±2.22dB Bandwidth ±5% Conducted Spurious Emission ±2.77 dB Restricted Frequency Bands ±5% Radiated Emission ±2.95dB Conducted Emission ±2.44dB This uncertainty represent an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2 MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 66 of 69 REPORT No.SZ19030188W05 Annex B Testing Laboratory Information 1. Identification of the Responsible Testing Laboratory Laboratory Name: Laboratory Address: Telephone: Facsimile: Shenzhen Morlab Communications Technology Co., Ltd. Morlab Laboratory FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 2. Identification of the Responsible Testing Location Name: Address: Shenzhen Morlab Communications Technology Co., Ltd. Morlab Laboratory FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China 3. Facilities and Accreditations All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 67 of 69 REPORT No.SZ19030188W05 4. Test Equipments Utilized 4.1 Conducted Test Equipments Equipment Name Serial No. Attenuator 1 (N/A.) EXA Signal Analzyer MY53470836 USB Wideband Power Sensor MY54210011 RF cable (30MHz-26GHz) CB01 Coaxial cable CB02 SMA connector CN01 Computer T430i Type 10dB N9010A U2021XA RF01 RF02 RF03 Think Pad Manufacturer Resnet Agilent Agilent Morlab Morlab HUBER-SUHNER Lenovo Cal. Date N/A 2019.04.09 2019.04.16 N/A N/A N/A N/A Cal. Due N/A 2020.04.08 2020.04.15 N/A N/A N/A N/A 4.2 Conducted Emission Test Equipments Equipment Name Serial No. Type Receiver MY56400093 N9038A LISN 812744 NSLK 8127 Pulse Limiter (20dB) 9391 VTSD 9561-D Coaxial cable(BNC) (30MHz-26GHz) CB01 EMC01 Adapter HKC00550 N/A 10-3E Manufacturer KEYSIGHT Schwarzbeck Schwarzbeck Morlab ViVo Cal. Date 2018.05.08 2018.05.08 2018.05.08 N/A N/A Cal. Due 2019.05.07 2019.05.07 2019.05.07 N/A N/A 4.3 List of Software Used Description Test system N1918A Power Analysis Manager Power Analyzer MORLAB EMCR V1.2 Manufacturer Tonscend Agilent MORLAB Software Version V2.6 R03.09.10 V 1.0 MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 68 of 69 REPORT No.SZ19030188W05 4.4 Radiated Test Equipments Equipment Name Serial No. Receiver MY54130016 Test Antenna Bi-Log 9163-519 Test Antenna Loop 1519-022 Test Antenna Horn 01774 Test Antenna BBHA9170 Horn #774 Coaxial cable (N male) CB04 (9KHz-30MHz) Coaxial cable (N male) CB02 (30MHz-26GHz) Coaxial cable (N male) CB03 (30MHz-26GHz) 1-18GHz pre-Amplifier MA02 18-26.5GHz pre-Amplifier MA03 Notch Filter N/A Anechoic Chamber N/A Type N9038A VULB 9163 FMZB1519 BBHA 9120D BBHA9170 EMC04 EMC02 EMC03 TS-PR18 TS-PR18 WRCG-24002483.5-60SS 9m*6m*6m Manufacturer Agilent Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck Morlab Morlab Morlab Rohde& Schwarz Rohde& Schwarz Wainwright CRT Cal. Date 2018.08.04 2018.05.18 2019.02.15 2018.08.06 2018.08.02 N/A N/A N/A 2018.05.08 2018.05.08 2018.12.01 2017.11.19 Cal. Due 2019.08.03 2019.05.17 2020.02.14 2019.08.05 2019.08.01 N/A N/A N/A 2019.05.07 2019.05.07 2019.11.30 2020.11.18 END OF REPORT MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 69 of 69Acrobat Distiller 9.3.2 (Windows)