AT8502DÓ¢ÎÄ˵Ã÷Êé

΢ÈíÓû§

Download ATTEN AT8502D SMD rework station user manual

SMD Rework Station ATTEN AT8502D (110 V) - GsmServer

SOLDERING STATION SMD REWOEK

AT8502D Manual

Atten AT8502D Professional Hot Air Rework and Soldering Station | pcb-soldering.co.uk - PCB Soldering

PDF preview unavailable. Download the PDF instead.

AT8502D manual
ATTEN INSTRUMENTS

RF Microwave Instruments RF Microwave Components Spectrum Analyzers Regulated DC Power Supply Regulated AC Power Supply Switching DC Power Supply Digital Storage Oscilloscope Signal Generator Attenuator 850 Rework Station 936 Constant Temp Soldering Station Electronic Instruments Electronic Tools

Amplifier

FRANCHISER

AT8502D
SOLDERING STATION SMD REWOEK 2 in 1
THERMO-CONTROL ANTI-STATIC Intelligent lead-free rework station User's Manual

MFR Add: Building A29, Tanglang Industrial Zone, Xili, Nanshan, Shenzhen, 518055, P. R. China

CBN 019006

Installation:
The brackets for the handles must be installed when operating for the first time. Please see the following illustration:
1. Please fix the bracket by tightening the four screws according to the illustration and your personal habit.
2. According to your selection, dismantle the two screws on the left or the right, which fix the bracket of the handle.
3. Place the two installation hole of the bracket to the two fixed screw holes of the machine, and then tighten the dismantled two screws. Put the components of the handle on the bracket to check if it is suitable.

Power: Upon power on the unit, the reworking station and soldering station be standby.

Standby state of screen A

Standby state of screen B

(diagram 1)

(diagram 2)

. REWORK STATION
1. Power on: Rework station start to work after press the "POWER" knob at the left of panel.

Introduction for LCD display:

A screen (rework station, same as below)

Display of status

Setting value and display of real temperature

Temperature unit

B screen (soldering station, same as below)

Display of status

Setting value and display of temperature

Temperature unit

Power direction Working mode Setting temp. Air flow display

Power direction Memory temp. 1 Memory temp. 2 Memory temp. 3

Description for LCD display
Display "- - -" means the device is standby Screen "A" displays the working state of rework station. "P_ _" eans rework station is under the normal setting condition. " P 0 1 " means rework station is under the condition set by memory group 1. " P 0 2 " means rework station is under the condition set by memory group 2. " P 0 3"means rework station is under the condition set by memory group 3. Both screen A and screen B display " OFF" in the memory temperature area 2, which means the device, is standby. When the temperature area shines the station is under the condition available to set.

7

2. At that time, if the handle is on the bracket, screen "A" display state standby (diagram 3), or display the setting temperature and 3 seconds later it display the actual temperature (diagram 4, diagram 5).

Screen A: Standby

Screen A:

Screen A:

Setting Temperature Actual Temperature

(diagram 3)

(diagram 4)

(diagram 5)

3. Temperature Settings

In normal condition, there are two methods to set temperature of hot-air

reworking station.

A. If screen A shines setting temperature through operating the

button of panel. If screen A doesn't shine

you must press the

"SET"button to switch to shine of screen A then the station

8

Under the setting condition. Then you can press "SET" button to set hot -air rework station' s temperature and the main temperature area shines the setting temperature, you can press UP knob or DOWN knob to adjust the setting temperature. 4s-no-press or press SET knob, you can keep the temperature and quit out this setting. (Diagram 6).
A. Setting temperature via handle of rework station. You can press UP knob or DOWN knob directly to adjust temperature and the main temperature area indicators setting temperature. 4s-no-press or press SET knob, you can keep the temperature and quit out this setting, at that time, you can adjust hot-air volume by pressing " " Whether screen A or screen B shine as you set, the device is under the setting condition and shining area for switch to screen "A " automatically.
Notice: continually pressing UP or DOWN knob in long time will quickly adjust the temperature, at that time, the screen don't shine. (Same as below description)
(diagram 6)

(diagram 7)
5. Storing the Temperature values
Under normal working condition, hold down POWER knob at the left of panel, at the same time long press (>5s) the UP knob or DOWN or SET to adjust temperature and air volume to the required values separately in term 1 or term 2 or term 3. But when you hold down POWER knob at the left of panel and short press (<5s) UP or DOWN or SET knob to use the storage setting temperature and air volume into current work temperature and air volume (diagram8, diagram9, diagram10). (Notice: up, down, set refer to storage term 1, term 2, term 3)

4.Hot-air volume settings

In normal working condition, there are two methods to set hot-air volume:

A. If screen A shines setting temperature through operating the

button of panel. If screen A doesn't shine you must press the "SET"

button to switch to shine

of screen A then the station under the

setting condition. Then you can press "SET" button to set hot-air rework

station' s temperature and the main temperature area shines the setting

temperature, you can press UP knob or DOWN knob to adjust the setting

temperature. 4s-no-press or press SET knob, you can keep the

temperature and quit out this setting (diagram 7).

B. Setting hot-air volume via handle of rework station. You can press UP knob or DOWN knob to adjust hot-air volume and the main temperature area indicators setting volume. 4s-no-press or press SET knob, you can keep the volume and quit out this setting, at that time, you can adjust hot-air volume by pressing " " When the screen A or screen B shine as you set, the device is under the setting condition and shining area for switch to screen"A" automatically.

9

Screen A: Working state of shortcut 1

Screen A: Working state of shortcut 2

Screen A: Working state of shortcut 3

(diagram 8)

(diagram 9)

(diagram 10)

6.Temperature comp temperature and calibration
Under normal working condition, hold down both POWER knob at left of panel and " " knob on the handle to calibrate. Screen A will display the character CAL, and temperature value can be calibrated by pressing UP or DOWN knobs. Pressing the SET knob to confirm storage and quit from this calibration (diagram 11).

10

(diagram 11)
7. Dormancy Under normal working condition, when the user put the handle on the bracket, then the equipment will be automatically switch to the dormancy condition and the heater also stops heating. This happens in the case when the temperature is higher than 100 , during the hot-air station dormancy period the screen A display character SLP (diagram 3)
Screen A: Standby

(diagram 3)
8.Conversation between cold-air and hot-air
In normal condition, continually press " "knob twice and then make the hot-air be in the state of cold-air blow (diagram12). Under the cold-air condition, press " " knob once, recover the hot-air working condition.

(diagram 12)
9.Standby
Under normal working condition, the device keep the current temperature and air volume and cut down heating to the rework station after pressing POWER knob at the left of panel (diagram 1A), below 100 , the device is standby (diagram1). If power is off, the soldering station is off, whole device will be off after the temperature below 100 .
Standby state of screen A

(diagram 1A)

(diagram 1)

11

10. Error/Fault indication

1. When "H-E" is displayed on the screen A, there is no hot air in the nozzle (diagram13), which indicates that the heating element fails.
2. When "S-E" is displayed on the screen A, there is a fault in sensor (diagram14), which signifies that there is something wrong with the sensor or the related circuit of the sensor.

Screen A: no hot-air fault

Screen A: sensor fault

(diagram 13)

(diagram 14)

II. SOLDERING STATION
1.Power on
Screen B which displays actual temperature in 3s displays setting temperature after pressing POWER knob at the right of panel (diagram15, diagram16).

Screen B: Temperature Settings

Screen B: heating

(diagram 15)

(diagram 16)

2.Temperature setting

In normal working condition, if screen B shines

or you at first continually

press SET knob twice to switch to shine

, then press the UP or DOWN knob

to adjust temperature. Screen B shines"SET" and the main temperature area

shines the setting temperature of soldering station. Stopping pressing knob or

pressing SET knob confirm and keep settings and quit from this operation

(diagram17).

12

(diagram 17)
3.Shortcut keys set storage
Under normal working condition, hold down POWER knob at the left of panel, at the same time long press (>5s) the UP knob or DOWN or SET to adjust temperature to the required values separately in term1 or term2 or term3. When you hold down POWER knob at the left of panel and short press (<5s) UP or DOWN or SET knob to use the storage setting temperature into current work temperature and air volume. (Notice: up, down, set refer to storage term1, term2, term3)

5.Standby
In normal working condition, press POWER key at the right of panel to make the device be standby (diagram 2). Make the power off, at the same time, the soldering station is off and the whole station will off when the temperature is low to 100 .
Standby state of screen B

(diagram 2)

6.Error/Fault indication

A. When "H-E" is displayed on the screen A, there is no temperature (diagram19),which indicates that the heating element fails.
B. When "S-E" is displayed on the screen A, there is a fault in sensor (diagram20), which signifies that there is something wrong with the sensor or the related circuit of the sensor.

Screen B: fault of heating

screen B: fault of sensor

4.Temperature comp temperature and calibration
Under normal working condition, hold down both POWER knob at right of panel and " " knob on the handle to calibrate soldering station temperature (diagram18). Temperature value can be calibrated by pressing UP or DOWN knobs. Pressing the SET knob to confirm storage and quit from this calibration (diagram 11).
(diagram 18)
13

(diagram 19)

(diagram 20)

III. Conversion of temperature unit
Under the power off condition, hold down the UP, DOWN and SET knob and then put power on to switch / .
IV. Replacement of heater
Please follow the following steps for the successful replacement of the heating element of hot-air rework station:
A. Cut down power, please refer to the following diagram to replace heater after it is cool.
B. Based on diagram, loosen the three screws of the handle. C. Dismantle the upper cover of the handle, pull out the ground wire on the
duct and take out the fan. D. Take out the heating element from PCB board.

14

E. Insert new heating element in PCB board, pay attention to install properly. F. Install it as the contrary method of remove.
Top shell
Quartz tube PCB
Hot air tube
Lower shell
heating element Please follow the following steps for the successful replacement of heating element of soldering station:
A. Cut down power; replace the heating element after it is cool. B. As following diagram, unscrew the nut , take out the stainless steel
cap and iron tip , then unscrew the fixed holder , desoldering the heating element . C. Replace the good condition heating element and install it as the contrary method of remove.

List of accessories:
AT8502D1 unit Power cord 1 strip Nozzle 1 set Bracket 1 set 907 handle 1 pc 905 iron holder 1 set User manual 1 copy

1 unit 1 strip 1 set 1 set 1 pc 1 set 1 copy

WARNING: This tool beplaced on itsstand when notin use
The instructions for heat guns and hand-held paint strippers shall include the substance of following:
A fire may result if the appliance is not used with care, therefore be careful when using the appliance in places where there are combustible materials:
Do not apply to the same place for a long time; Do not use in presence of an explosive atmosphere; Be aware that heat may be conducted to combustible materials that are out of sight ; Place the appliance on its stand after use and allow it to cool down before storage; Do not leave the appliance unattended when it is switched on;

15