User Manual for SALUS models including: SALUS, Wired, Digital, Thermostat, Non-programmable, HTRS230
In manual mode, only one temperature level is maintained for the entire day. Icon in the frame indicates which mode is currently active. A different temperature ...
Manual mode – temperature setpoints. 3 temperature levels are available. In manual mode, only one temperature level is maintained for the entire day.
Introduction. The HTRS230V(30) from SALUS Controls is a digital, wired and surface- mounted (or on a flush-box) non programmable room thermostat,.
VI 2020 [ENG] AC 230V Wired digital thermostat - non-programmable Model: HTRS230(30) Package content User manual Ver. 1 Date of issue: 24 VI 2020 Power supply: 230V IMPORTER: QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice PRODUCER: Salus Limited 6/F, Building 20E, Phase 3, Hong Kong Science Park, 20 Science Park East Avenue, Shatin, New Territories, Hong Kong Front housing of the thermostat Digital non-programmable thermostat Model: HTRS230(30) Back housing of the thermostat User manual User manual Mounting screws Proper thermostat location www.salus-controls.eu SALUS Controls is a member of the Computime Group. In accordance with the product development policy, SALUS Controls plc reserves the right to change specifications, design, and materials used in production, presented in this manual, without prior notice. Introduction The HTRS230V(30) from SALUS Controls is a digital, wired and surfacemounted (or on a flush-box) non programmable room thermostat, dedicated for surface heating / cooling control, characterized by high thermal inertia. It is connected to the wiring centre. The thermostat does not have the function of creating schedules - it lowers the set temperature via wiring centre after receiving the NSB signal from the weekly thermostat. Thanks to the built-in algorithms, it offers much better temperature control accuracy than traditional mechanical thermostats. The thermostat is characterized by silent operation. The controller is characterised by silent operation. Product compliance The product complies with the following EU directives: 2014/30/EU, 2014/35/EU, 2011/65/EU. Full information is available at www.saluslegal.com Note! This document is a quick guide to the installation and operation of the product and indicates its main features and functions. Detailed informations are in the full manual, which is available at www.saluscontrols.eu and which must be used for proper installation and operation of the product. Safety informations: Use in accordance with national and EU regulations. Use the device as intended and keep it dry. Product for indoor use only. Please read the entire manual before starting the installation and using the product. Installation: Installation must be carried out by a qualified person, with appropriate electrical authorisations, in accordance with national and EU standards and regulations. The manufacturer shall not be liable for failure to comply with the manual. NOTE: There may be additional protection requirements for the entire installation. The installer shall be responsible for compliance with such requirements. The ideal position to thermostat mounting is about 1,5m under floor level far from heating or cooling sources. In addition, the thermostat should not be installed behind curtains or other obstacles or in places with high humidity, as this will prevent accurate measurements of room temperature. The thermostat must not be exposed to sunlight. Do not place the thermostat on an outer wall. Connection description Note:The thermostat is compatibile with the following Salus wiring centre models:KL06 230V, KL08NSB 230V, KL04NSB 230V or directly to the actuator. NSB input CO ThHeTrRmS 2o3s0tat ATc3tu0aNtoCr N / L L N ThHeTrmRSo2s3t0at CO L N SL WKirLin08gNceSBntre L N Symbols explanation Terminal Description L, N Power supply (230V AC) NSB Night temperature reduction (230V output) SL 230 V AC output signal 230V AC CO Switching jumper between heating and cooling (input 230V AC) Note: The following designations are used interchangeably for products: = SL = NSB Montage 1 2 Make sure that the thermostat is not connected to the 230V AC. Then open the front housing using a screwdriver as shown above. 3 Connect the thermostat properly. Please refer to the "Connection description" section. Mount the thermostat using the designed screw holes. 4 Slide the thermostat on the back cover. The thermostat is configured for operation. Use buttons to set the temperature setpoint. Button functions Increase /or decrease setpoint temperature setpoint or value Mode selection Short press to confirm selection Press and hold enter / exit the menu LCD icon description 4 5 6 7 3 2 8 1 9 10 1. Heating mode 2. Cooling mode 3. Active work mode 4. Comfort temperature mode 5. Economic temperature mode 6. AUTO mode 7. Frost protection mode 8. Temperature unit 9. Current / set temperature 10. Manual mode / temp. override Manual mode temperature setpoints 3 temperature levels are available. In manual mode, only one temperature level is maintained for the entire day. Icon in the frame indicates which mode is currently active. A different temperature can be set for each level. - Comfort temperature mode - Economic temperature mode - Frost protection mode Usually used during the period of longer absence, or during the holidays (only available in HEATING mode). Press any button to highlight the screen, then follow the steps below: 1 2 Select the temperature mode using or buttons. Temperature setpoint Press any button to highlight the screen, then follow the steps below: 1 2 Current temperature. 3 Temperature setpoint in the selected work mode. 4 Set the temperature using or buttons. Confirm selection by button. AUTO mode NSB function The NSB (Night Setback) function enables automatic reduction of the temperature setpoint on the HTRS230(30) SLAVE thermostat, via the HTRP230(50) programmable MASTER thermostat connected to the wiring centre (or other external clock). The temperature change takes place between the comfort temperature mode and economic temperature mode. To activate AUTO mode, select the icon. Together with the icon, the thermostat shows the active temperature mode on the display: or . Press any button to highlight the screen, then follow the steps below: 1 2 Select AUTO mode using or buttons. Note:For the proper NSB function work, an appropriate cable connection is required.The connection description is on the previous page. Calibration of displayed temperature "offset" function The thermostat allows to correct the displayed temperature by ±3.0°C. Follow the steps below: Press any button to highlight the screen, then follow the steps below: 1 2 Press and hold button to enter the menu. Confirm "offset" setting by button. 3 4 Set the temperature calibration value using or buttons. Temperature calibration can be made in the range from -3.0°C to +3.0°C. Confirm the selected value by button. Note:Calibration of the temperature can also be set in the installer parameters (parameter d02). Heating / Cooling mode Manual change: Modes are indicated by symbols. Press and hold button to enter the menu, then use button to select the Heating / Cooling mode change setting. Confirm changes using button. Now use or buttons to set the heating or cooling mode. Confirm by button. Automatic change (via CO terminal): The heating/cooling mode can be changed automatically via the CO terminal in the thermostat. If 230 V AC power supply is connected to the CO terminal then thermostat automatically switches to cooling mode. If you want to use this function, then you have to change the value of the d18 parameter to "1". Cooling blocking: When D19 thermostat parameter is set to "1", then cooling is blocked for a single room. When the cooling function is blocked, no message is displayed. Installer mode Press any button to highlight the screen, then follow the steps below: 1 2 3 sec. 3 sec. Press and hold and buttons simultaneously for 3 seconds. Select the 47 code using or buttons. 3 4 Confirm by button. You are now in the installer menu. Select the parameter you wish to change by or buttons and enter using button. Use and to set the value of the parameter, and then confirm it with . Installer parameters Function Parameter Description Values Default Values According 0 to the PWM algorithm d01 Heating Control Hysteresis: 1 0.5 °C 0 (± 0.25 °C) Hysteresis: 2 1.0 °C (± 0.5 °C) Displayed d02 temperature correction If the thermostat indicates from an incorrect -3.0°C temperature, 0.0°C to +3.0°C then it can be corrected ±3.0°C d05 Cooling Control Hysteresis: 1 0.5 °C (± 0.25 °C) 2 Hysteresis: 2 1.0 °C (± 0.5 °C) 0 Disabled d07 Valve Protection 1 1 Enabled d08 Frost protection setpoint The frost protection 5.0 17.0°C temperature is maintained for example during 5.0°C active holiday mode. d12 Heating setpoint limits 5.0 35.0°C Maximum temperature which can be set for heating 35.0°C Minimum d13 Cooling setpoint limits 5.0 40.0°C temperature which can be set for cooling 5.0°C d18 Heat/Cool Mode Selection 0 Manual by buttons use 0 1 Automatic by the CO terminal d19 Cooling Blocking function 0 Cooling allowed 1 Cooling disabled 0 Numbers 1 Actuators loading to 5 are the d20 selection for different temperature 0 5 numbers of actuators con- 0 compensation nected to the thermostat. Factory reset If you made a mistake, want to change the thermostat parameters or return to factory settings, follow the steps below. Note:This action will permanently delete all current settings. Press any button to highlight the screen, then follow the steps below: 1 2 3 sec. 3 sec. Press and hold and buttons simultaneously for 3 seconds. Select the 49 code using or buttons. 3 4 Confirm by button. Press button to reset the thermostat. 5Adobe InDesign 16.1 (Windows) 3-Heights(TM) PDF Optimization Shell 5.9.1.5 (http://www -tools.com)