Assembly
Assemble Multiple Button Switches
- Begin with a standard (assembled) 1 or 5 control button DecoFlex switch. Using a small flat blade screwdriver, carefully separate the SWITCH BASE ASSEMBLY from the FACEPLATE.
- Add or remove CONTROL BUTTONS as required from the SWITCH BASE ASSEMBLY. Ensure the SWITCH BASE ASSEMBLY remains intact.
- Attach a new multiple button face plate.
Exploded View of 5 Channel DecoFlex Wall Switch: The components include Removable Channel Buttons, Switch Base Assembly, 8 Button Faceplate, and Wall Plate.
Visual Description: Figure 1 shows separating the switch base from the faceplate. Figure 2 shows adding or removing buttons. Figures 3 and 4 show attaching a new faceplate.
Replace Standard Control Buttons
- Using a small flat blade screwdriver, carefully separate the SWITCH BASE ASSEMBLY from the FACEPLATE.
- Replace standard (blank) or temporarily labeled CONTROL BUTTON(s) with new printed CONTROL BUTTON(s).
- Attach a new CONTROL BUTTON FACE PLATE.
Visual Description: Figures 3 and 4 illustrate the process of attaching a new faceplate to different switch assemblies (5 Button, 6 Button, 7 Button Switch Assembly).
SDN, animeo IP and Dry Contact
Keypad RJ45 Pinout
Uses CAT-5e or higher TIA-568B standard with RJ-45 connector.
Pin # | Color | SDN & animeo IP Function | Dry Contact Function |
---|---|---|---|
1 | Orange White | SDN RS485 (+) | IP1 |
2 | Orange | SDN RS485 (-) | IP2 |
3 | Green White | Reserved | IP3 |
4 | Blue | Power 24v DC (+) | 12V+ |
5 | Blue White | Power 24v DC (-) | N/A |
6 | Green | Reserved | Down |
7 | Brown White | SDN RS485 Ground | Up |
8 | Brown | SDN RS485 Ground | Ground |
SDN Cable Pinout
(RJ45 connector) ANSI/TIA/EIA 568-B Standard
(Note: The PDF shows a diagram for SDN Cable Pinout which is identical to the Keypad RJ45 Pinout table above, listing functions like IP1, IP2, IP3, 12V+, N/A, Down, Up, Ground. For clarity, the table above covers both.)
Powering DecoFlex Keypads
Battery Replacement: (RTS only)
The DecoFlex WireFree™ RTS switch is designed for maintenance-free performance. If the battery is discharged, the LED indicator lights will not function when a channel button is selected or an Up/Stop/Down command is activated, reducing or preventing communication with the RTS receiver or motor.
To replace the battery: Expose the SWITCH BASE ASSEMBLY board. Slide the old battery out of its holder and replace it with a new 3V Lithium battery (type 2450), ensuring correct polarity.
NOTE: Batteries should be disposed of properly according to local regulations.
Keypad Programming
Download and install the Programming Software from: https://www.somfysystems.com/support/tools/configuration-tools-software
- RTS: Follow the RTS Pocket Programming Guide to set up DecoFlex RTS keypads.
- Dry Contact: Arrange the switch for control in the IGC 4n1 Motor Controller. *Before installing keypads, all motors must be wired to the controller, have limits set, and be working properly.
- SDN: DecoFlex Digital Keypads for SDN have programmable buttons configurable to control any motor or group using the SDN Keypad Programming Guide and SDN Keypad Configuration Software. Settings can be exported to a file for backup.
- animeo® IP: Keypads are configured within the animeo® IP commissioning software after installation on the SDN bus, using the animeo® IP Visual Configuration software.
Installation
A special SOMFY low voltage device mounting bracket is included, which attaches to drywall and eliminates the need for an electrical box. The bracket can be used in two mounting configurations:
- Adjacent Switch Mounting: The bracket is designed for mounting wall switches to an adjacent (pre-existing) Decora style light switch. This allows spacing for two adjacent switches and a "Double Gang" wall plate for a professional installation.
NOTE: This mounting bracket is not designed for use with "old-work" or retrofit electrical boxes. Check local codes to determine if an electrical box is required. For improved radio performance, Somfy recommends non-metallic electrical enclosures.
- Stand-alone Mounting: The bracket can also be used for individual or "stand-alone" (1 switch) mounting configurations.
Tools Required for Installation:
Screw drivers (Phillips and Bladed), Dry-wall saw, Wall stud sensor, Non-marring tape and pencil.
Installation Steps:
- Locate an existing light switch and remove the wall plate, exposing the electrical box. Somfy recommends shutting off power to the exposed electrical box prior to installation. If not installing with an existing switch, skip to step 2.
- Using a stud sensor, locate the stud nearest to the exposed electrical box. Mark the location with removable tape or pencil.
- Place the flat side of the mounting bracket against the wall. Align the thin side over the outside edge of the existing electrical box (opposite the stud side). Center the bracket to align the mounting screw height with the existing switch, then trace the inside shape of the bracket on the wall using a pencil or thin marker.
- Using a dry-wall saw, cut the drywall along the traced outline. Do not cut the hole larger than the outline to prevent a loose fitting bracket. *For greater accuracy, refer to the recommended hole dimensions: 1 5/8" W x 3 7/16" L.
- Insert the bracket into the hole, keeping the thin side closest to the edge of the existing switch box.
- Carefully bend the bracket tabs 90 degrees behind the drywall to ensure a tight, secure fit.
- Position the DecoFlex switch into the mounting bracket, aligning the screw holes. Secure the switch to the bracket with the provided screws.
- Attach a new (2 gang) or double gang Decora style wall plate over both switches to complete the installation.
Operation
- Select the CONTROL BUTTON(s) programmed to a specific window covering. The adjacent LEDs will illuminate to indicate the selected button.
- To raise the window covering(s), press the UP button.
- To lower the window covering(s), press the DOWN button.
- To stop the window covering(s) at any time, press the STOP button.
- For RTS and SDN keypads programmed for group function, select a control button followed by an action (default: up, stop, and down).
For detailed product operation information, refer to the product programming instructions.
NOTE: Keypads require programming in order to operate as intended.
Visual Description: Figure 2 shows the keypad layout with LED Indicators, an RTS Programming Button (for RTS only), Control Buttons, a Stop Button, an Up Button, and a Down Button.