59SC6A-01PD REV B

woodl

59SC6A-01PD - Carrier

20 set 2022 — The 59SC6A Multipoise Comfort™ Condensing Gas Furnace features year-round electrical efficiency when paired with a compatible condensing unit.

59SC6A-01PD REV B - Carrier

59SC6A: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

PDF preview unavailable. Download the PDF instead.

59SC6A-01PD
+
59SC6A ComfortTM 96, Single-Stage, Multi 18-Speed ECM, Condensing Gas Furnace

Product Data

A11263
Representative drawing only. Some product models may vary.
! WARNING
CARBON MONOXIDE POISONING AND FIRE HAZARD Failure to follow this warning could result in personal injury, death, and/or property damage. This furnace is not designed for use in recreation vehicles or outdoors. This furnace is designed for use in manufactured (Mobile) homes when an optional Mobile Home accessory kit is installed. Failure to follow this warning could result in personal injury, death, and/or property damage.
The 59SC6A Multipoise ComfortTM Condensing Gas Furnace features year-round electrical efficiency when paired with a compatible condensing unit. Energy efficiency is at the heart of this furnace with up to 96.5% AFUE, gas efficiency and the electrically-efficient fixed-speeds, constant torque (MCT) ECM blower motor. Improved serviceability with the 3 digit status display and NFC enabled board allowing setup via the service tech app. This gas furnace also features 4-way multipoise installation flexibility, and is available in eleven model sizes. All sizes except the 26,000 BTUh model can be vented for direct vent/two-pipe, ventilated combustion air, or single-pipe applications. The 26,000 BTUh model can use the same 2-pipe venting system using outside air for combustion, but is not considered direct-vent. All sizes are design certified in Canada, and select sizes are certified for mobile/manufactured home use with conversion kit accessory.

PERFORMANCE
· Multi 18-speed, constant torque (MCT) ECM blower motor for electrically efficient operation all year long in heating, cooling and continuous fan operation.
· Enhanced diagnostics with easy to read 3-digit display for faults and status.
· Single-speed inducer motor, and single-stage gas valve. · Silicon Nitride PowerHeatTM Hot Surface Igniter. · Dual fuel capable HybridHeatTM with a compatible heat pump and
thermostat for energy-saving heating performance · Adjustable blower speed for heating and cooling. · Aluminized-steel primary heat exchanger. · Stainless-steel condensing secondary heat exchanger.
INSTALLATION FLEXIBILITY
· On-board NFC antenna makes setup a tap away when using the Carrier service technician app.
· 4-way multipoise design for upflow, downflow or horizontal installation, with unique vent elbow for optional venting through-the-cabinet downflow venting capability.
· Factory-configured ready for upflow applications. · Ideal height 35" (889 mm) cabinet: short enough for taller coils, but
still allows enough room for service. · Two-pipe venting, single-pipe venting or ventilated combustion air.
APPLICATIONS
· Approved for Twinning applications with accessory kit (060E17--14, 080E17--16, 080E21--20, 100E21--20, 120E24--22, 140E24--22 models, only).
· Approved for Manufactured Housing/Mobile Home applications with MH accessory kit.
· Convertible to propane with gas conversion accessory kit.
CERTIFICATIONS
· All sizes meet ENERGY STAR® Version 4.1 criteria for gas furnaces: 95%+ AFUE.
· Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193.
· All sizes can be installed in air quality management districts with a 40 ng/J NOx emissions requirements.
A200351

59SC6A: Product Data

FURNACE SIZE
026M14--10 040M14--10 040M17--12 060M14--12 060M17--16 080M17--16 080M21--20 100M21--20 100M21--22 120M24--22 140M24--22

A
CABINET WIDTH 14-3/16 (361) 14-3/16 (361) 17-1/2 (445) 14-3/16 (361) 17-1/2 (445) 17-1/2 (445) 21 (533) 21 (533) 21 (533) 24-1/2 (622) 24-1/2 (622)

Dimensional Drawing

Dimensions

B
OUTLET WIDTH 12-1/2 (319) 12-1/2 (319) 15-7/8 (403) 12-1/2 (319) 15-7/8 (403) 15-7/8 (403) 19-3/8 (492) 19-3/8 (492) 19-3/8 (492) 22-7/8 (581) 22-7/8 (581)

C
BOTTOM INLET WIDTH 12-9/16 (322) 12-9/16 (322) 16 (406) 12-9/16 (322) 16 (406) 16 (406) 19-1/2 (495) 19-1/2 (495) 19-1/2 (495) 23 (584) 23 (584)

D
AIR INTAKE 7-1/8 (181) 7-1/8 (181) 8-3/4 (222) 7-1/8 (181) 8-3/4 (222) 8-3/4 (222) 10-1/2 (267) 10-1/2 (267) 10-1/2 (267) 12-1/4 (311) 12-1/4 (311)

A210796
SHIP WT. LB (KG) 119 (54) 123 (56) 130 (59) 129 (59) 142 (64) 150 (68) 158 (72) 167 (76) 167 (76) 181 (82) 189 (86)

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2

59SC6A: Product Data

MODEL NUMBER NOMENCLATURE

6

1, 2

3

4

5

Major

7, 8, 9

Gas Furnace

Heating Stages

Tier

Min. AFUE/NOx Series

Heating Input

59

M

N

7

B

060

|

|

|

|

|

|

10 Motor Type
E |

11, 12 Width
17 |

13 Voltage (1-phase)
1 |

58 = 80% Non-Condensing
59 = 90%+ Condensing

M = Modulating T = Two Stage

B = Base C = Comfort
E = Export

0 = 80% 1 = 80% Low NOx
(Not Ultra Low NOx)

C = Constant Airflow Variable- Speed (VCA) ECM

S = Single Stage

N = Infinity

2 = 92%

V = Variable-Speed

C = Single Stage P = Performance

5 = 95%

026 = 26,000 BTU

(VCT) PWM

Communicating

U = Ultra Low

6 = 96% A 040 = 40,000 BTU M = Multi 18-Speed

Nox

7 = 97% B 060 = 60,000 BTU Constant Torque

8 = 98% C ---

(MCT) ECM

--- 155 = 155,000 BTU

14 - 14.2" 17 - 17.5" 21 - 21.0" 24 - 24.5"

1 = 110V/60Hz 2 = 230V/50Hz

14 Minor Series
1 |
1 2 3 ---

15, 16 Airflow
16 |
08 = 800 CFM 10 = 1000 CFM 12 =1200 CFM 14 = 1400 CFM 16 = 1600 CFM 20 = 2000 CFM 22 = 2200 CFM

FURNACE COMPONENTS

GAS BURNER

HOT SURFACE IGNITER MANUAL RESET
ROLLOUT SWITCH

FLAME SENSOR MANUAL RESET ROLLOUT SWITCH
GAS VALVE
OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE).
ELECTRICAL JUNCTION BOX (IF REQUIRED, LOCATION MAY VARY)
BLOWER DOOR SAFETY SWITCH

FURNACE CONTROL BOARD

MAIN LIMIT SWITCH (BEHIND GAS VALVE)
INDUCER MOTOR ASSEMBLY
BLOWER AND MOTOR

RATING PLATE NOT SHOWN (LOCATED ON BLOWER DOOR)

For California Residents:

A190145

If installed with a manufactured (mobile) home conversion kit in SCAQMD: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com

A220581
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

POSITION REAR
FRONT (Combustion air openings in furnace and in structure) Required for service
All Sides of Supply Plenum Sides Vent
Top of Furnace
*. Consult local building codes

CLEARANCE 0
1 in. (25 mm)
*24 in. (610 mm) *1 in. (25 mm) 0 0 1 in. (25 mm)

The furnace should be sized to provide 100 percent of the design heating load requirement plus any margin that occurs because of furnace model size capacity increments. None of the furnace model sizes can be used if the heating load is 12,000 BTUh or lower. Use Air Conditioning Contractors of America (Manual J and S); American Society of Heating, Refrigerating, and Air-Conditioning Engineers; or other approved engineering method to calculate heating load estimates and select the furnace. Excessive oversizing of the furnace may cause the furnace and/or vent to fail prematurely, customer discomfort and/or vent freezing.
Failure to follow these guidelines is considered faulty installation and/or misapplication of the furnace; and resulting failure, damage, or repairs may impact warranty coverage.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3

59SC6A: Product Data

SPECIFICATIONS

UNIT SIZE HEATING AND CAPACITY AND EFFICIENCY Input BTUh* Output Capacity (BTUh))

Certified Temperature Rise Range - °F (°C)

AFUE

Upflow/Hz Downflow

AIRFLOW CAPACITY AND BLOWER DATA

Rated Certified External

Heating

Static Pressure

Cooling

Airflow CFM @ Rated ESP (CFM)

Heating Cooling

Direct Drive Motor HP

Motor Full Load Amps

Heating Blower Control (Htg OFF-Delay)

Cooling Blower Control (Clg OFF-Delay)

Blower Wheel Diameter x Width - In. (mm)

Air Filtration System

Filter used for Certified Watt Data

ELECTRICAL DATA

Unit Volts-Hertz-Phase

Operating Voltage Range

Min-Max

Maximum Unit Amps

Unit Ampacity

Maximum Wire Length (Measure 1 way in Ft/M)

Minimum Wire Size

AWG

Max. Fuse/Ckt Bk Size

(Time-Delay Type

Amps

Recommended)

Transformer Capacity (24 VAC output)

External Control Power

Heating

Available

Cooling

GAS CONTROLS

Burners

Gas Connection Size

Gas Valve (Redundant)

Mfr

Min. inlet pressure

(in.w.c.)

Max. inlet pressure

(in.w.c.)

Ignition Device

Factory installed orifice

CONNECTIONS

Communication System

Thermostat Connections

Accessory Connections

026M14--10
26,000 25,000 25-55 (14-31) 96.0%
95%
0.10 0.50 620 175-970 1/3 4.4
11x7 (279x178)
5.2 7.5 50/15.2 14
15
2

040M14--10 040M17--12 060M14--12 060M17--16

40,000 39,000 40-70 (22-39) 96.0%
95%

40,000 39,000 40-70 (22-39) 96.5%
95%

60,000 56,000 35-65 (19-36) 95.0%
95%

60,000 58,000 40-70 (22-39) 96.5%
95%

0.10

0.10

0.12

0.12

0.50

0.50

0.50

0.50

705

700

945

1030

155-1000

160-1075

200-1165

315-1580

1/2

1/2

1/2

3/4

6.3

6.7

6.3

8.8

Adjustable: 90, 120 (factory-set), 150, 180 seconds

Adjustable: 90 (factory-set), 5, 30 seconds

11x7

11x8

11x7

11x8

(279x178)

(279x203)

(279x178)

(279x203)

Field Supplied Filter

325531-40**

7.0 9.7 38/11.7 14

115-60-1

104-127

7.4

7.1

10.2

9.8

36/11.1

38/11.5

14

14

10.1 13.6 27/8.3 14

15

15

15

15

40VA 12VA 35VA

2

3

3

4

1/2 in. NPT

White RodgersTM

4.5 (Natural Gas)

13.6 (Natural Gas)

Silicon Nitride

Size 44

None G,C, W, Y, R EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y)

080M17--16
80,000 78,000 40-70 (22-39) 96.5%
95%
0.12 0.50 1290 370-1625 3/4 9.2
11x8 (279x203)
10.0 13.4 27/8.4 14
15
4

*. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions.
. Capacity in accordance with U.S. Government DOE test procedures. . Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required
for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency media filter. **. See Accessory List for part numbers available.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4

59SC6A: Product Data

UNIT SIZE HEATING AND CAPACITY AND EFFICIENCY Input BTUh* Output Capacity (BTUh))

Certified Temperature Rise Range - °F (°C)

AFUE
AIRFLOW CAPACITY AND BLOWER DATA Rated Certified External Static Pressure
Airflow CFM @ Rated ESP (CFM)
Direct Drive Motor HP Motor Full Load Amps Heating Blower Control (Htg OFF-Delay) Cooling Blower Control (Clg OFF-Delay)

Upflow/Hz Downflow
Heating Cooling Heating Cooling

Blower Wheel Diameter x Width - In. (mm)

Air Filtration System

Filter used for Certified Watt Data

ELECTRICAL DATA

Unit Volts-Hertz-Phase

Operating Voltage Range

Min-Max

Maximum Unit Amps

Unit Ampacity

Maximum Wire Length (Measure 1 way in Ft/M)

Minimum Wire Size

AWG

Max. Fuse/Ckt Bkr Size (Time-Delay Type Recommended)

Amps

Transformer Capacity (24 VAC output)

External Control Power Available

Heating Cooling

GAS CONTROLS Burners Gas Connection Size Gas Valve (Redundant) Min. inlet pressure Max. inlet pressure Ignition Device Factory installed orifice CONNECTIONS Communication System Thermostat Connections Accessory Connections

Mfr (in.w.c.) (in.w.c.)

080M21--20
80,000 78,000 40-70 (22-39) 96.5%
95%
0.12 0.50 1310 225-2125
1 11.5
11x10 (279x254)
13.1 17.3 33/10.1 14 15
4

100M21--20

100M21--22

120M24--22

100,000 97,000 40-70 (22-39) 96.3%
95%

100,000 97,000 40-70 (22-39)
96.3 95%

120,000 116,000 40-70 (22-39)
96.1 95%

0.15

0.15

0.20

0.50

0.50

0.50

1730

1710

1965

375-2145

450-2240

290-2240

1

1

1

11.7

11.0

11.5

Adjustable: 90, 120 (factory-set), 150, 180 seconds

Adjustable: 90 (factory-set), 5, 30 seconds

11x10

11x10

11x11

(279x254)

(279x254)

(279x279)

Field Supplied Filter

325531-40**

12.6 16.7 34/10.5 14
15

115-60-1 104-127
12.5 16.5 34/10.6 14
15
40VA 12VA 35VA

13.2 17.4 33/10.0 14
15

5

5

6

1/2 in. NPT

White RodgersTM

4.5 (Natural Gas)

13.6 (Natural Gas)

Silicon Nitride

Size 44

None G, C, W, Y, R EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y)

140M24--22
140,000 135,000
45-75 (25-42)
95% 95%
0.20 0.50 2040 380-2230
1 11.7
11x11 (279x279)
12.6 16.7 34/10.5 14 15
7

*. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions.
. Capacity in accordance with U.S. Government DOE test procedures. . Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required
for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency media filter. **. See Accessory List for part numbers available.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5

59SC6A: Product Data
AIR DELIVERY (with filter)

Unit Size 040M14--10 040M17--12 060M14--12

Airflow Setting
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Default Setting Cont. Fan
Heat
Cooling Cont. Fan
Heat
Cooling Cont. Fan
Heat Cooling

0.1 390 405 455 485 530 565 600 645 705 720 760 820 865 910 965 1005 1055 1100 415 450 480 525 565 605 655 700 740 780 830 880 930 980 1030 1085 1140 1220 440 460 510 575 605 665 700 750 810 865 915 955 1015 1070 1105 1165 1215 1270

Air Delivery - CFM (with filter)

0.2 335 355 405 440 485 525 560 605 665 685 730 785 835 885 935 975 1025 1075 350 385 420 470 515 555 605 655 695 740 790 840 895 945 995 1050 1105 1185 380 400 460 525 560 615 660 710 770 825 880 920 980 1040 1075 1135 1190 1240

0.3 275 300 355 390 440 485 520 570 630 650 695 755 805 855 905 950 1000 1050 290 325 360 415 460 505 560 610 655 700 750 800 860 910 960 1020 1080 1150 320 345 405 475 510 570 615 670 730 790 845 890 950 1005 1045 1105 1160 1215

External Static Pressure (IN.W.C.)

0.4

0.5

0.6

0.7

215

155

-

-

240

185

125

-

305

250

200

140

345

295

245

190

395

350

300

255

440

400

355

310

480

440

400

360

530

495

455

415

595

560

525

490

615

580

545

515

660

630

595

560

725

690

660

630

775

745

715

690

825

800

770

740

880

855

825

800

925

900

870

845

975

950

925

900

1025

1000

980

955

230

160

105

-

270

210

150

-

310

260

195

140

360

315

265

205

410

360

315

265

455

405

365

320

510

465

420

385

565

520

475

435

610

570

525

485

660

615

575

535

715

675

635

595

765

730

690

655

825

790

750

715

875

845

810

775

930

895

860

830

985

955

925

890

1045

1015

985

955

1115

1075

1040

1005

260

200

140

-

285

225

165

-

350

295

240

185

425

375

325

280

460

415

365

320

525

480

435

390

570

525

485

440

625

585

545

505

690

650

615

575

750

715

680

640

810

775

740

705

855

820

785

750

915

885

850

820

975

945

915

885

1015

985

955

925

1080

1050

1020

995

1135

1105

1080

1055

1190

1165

1135

1110

0.8 -
140 205 270 320 375 455 480 530 600 660 710 770 820 875 930
150 210 270 340 400 450 500 560 615 680 740 795 860 925 965 130 230 270 350 400 460 535 605 670 715 785 855 895 965 1025 1085

0.9 -
155 220 275 335 415 440 495 570 630 685 745 795 850 905
160 215 290 360 415 465 520 575 645 705 760 825 895 925 175 225 305 355 420 495 565 630 680 755 820 865 935 995 1060

1 170 230 300 380 405 460 535 600 655 715 765 825 880 170 240 310 380 430 490 545 610 670 730 795 865 885 170 260 315 385 460 530 595 650 720 790 835 910 970 1030

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 6

59SC6A: Product Data

Unit Size 060M17--16 080M17--16 080M21--20

Airflow Setting
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Default Setting Cont. Fan
Heat
Cooling Cont. Fan
Heat Cooling Cont. Fan
Heat
Cooling

0.1 590 640 710 755 835 890 960 1010 1040 1095 1165 1235 1315 1380 1455 1525 1605 1720 625 695 760 815 875 945 1005 1070 1145 1215 1295 1300 1355 1440 1515 1575 1655 1760 615 695 805 870 955 1070 1150 1245 1325 1415 1535 1610 1715 1820 1915 1995 2105 2305

Air Delivery - CFM (with filter) (Continued)

0.2 520 575 650 700 780 840 915 965 995 1055 1130 1200 1280 1345 1420 1495 1580 1685 560 635 700 765 820 895 960 1025 1100 1175 1255 1265 1320 1400 1480 1540 1625 1730 515 610 725 795 885 1005 1085 1185 1270 1360 1485 1560 1670 1775 1875 1960 2070 2260

0.3 455 515 595 645 730 790 870 920 950 1015 1090 1160 1245 1315 1390 1465 1550 1650 495 575 645 710 770 845 915 985 1060 1135 1215 1225 1280 1365 1445 1510 1590 1700 415 515 645 720 815 935 1025 1125 1215 1310 1435 1515 1625 1735 1835 1920 2035 2215

External Static Pressure (IN.W.C.)

0.4

0.5

0.6

0.7

380

315

250

185

445

375

320

260

535

470

410

355

590

535

465

410

680

630

580

515

745

695

645

595

825

780

735

690

875

835

790

745

910

870

825

785

975

935

895

855

1050

1010

975

940

1125

1090

1055

1020

1210

1175

1140

1110

1280

1250

1215

1185

1360

1330

1300

1270

1435

1410

1380

1350

1525

1500

1470

1445

1615

1580

1545

1505

430

370

310

250

515

455

400

345

590

530

480

430

660

605

550

500

725

675

620

570

800

755

710

655

870

830

785

740

940

900

855

815

1020

980

940

900

1095

1055

1020

980

1180

1145

1105

1070

1190

1155

1120

1085

1245

1210

1175

1135

1335

1300

1265

1230

1415

1380

1350

1320

1480

1450

1415

1385

1560

1530

1500

1470

1665

1625

1585

1535

325

225

140

-

430

340

255

165

560

485

405

325

640

560

490

415

740

670

595

530

870

805

740

675

960

900

835

775

1065

1005

950

890

1160

1105

1050

995

1255

1205

1150

1100

1385

1335

1285

1240

1465

1420

1375

1325

1580

1535

1495

1450

1690

1650

1610

1570

1795

1760

1720

1680

1885

1845

1810

1775

2000

1970

1935

1900

2170

2125

2080

2030

0.8 120 195 305 360 465 540 635 705 745 815 900 985 1075 1150 1240 1325 1420 1470 190 285 370 455 525 610 690 770 860 940 1035 1050 1100 1200 1285 1355 1440 1490
245 345 460 615 710 835 945 1045 1195 1280 1405 1530 1645 1740 1870 1985

0.9 -
130 245 310 420 490 580 650 700 775 865 945 1045 1120 1210 1295 1395 1430 130 235 325 400 475 565 645 725 820 905 1000 1010 1070 1165 1255 1320 1410 1450
165 270 390 545 650 775 885 995 1145 1235 1360 1485 1605 1700 1835 1935

1 175 260 370 445 535 605 650 730 830 915 1010 1090 1180 1270 1370 1395 175 270 355 430 525 610 685 775 865 960 980 1030 1130 1220 1290 1375 1405 195 330 485 590 720 830 945 1095 1190 1315 1445 1565 1665 1805 1890

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 7

59SC6A: Product Data

Unit Size 100M21--20 100M21--22 120M24--22

Airflow Setting
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Default Setting Cont. Fan
Heat Cooling Cont. Fan
Heat Cooling Cont. Fan
Heat Cooling

0.1 720 815 910 995 1105 1200 1290 1375 1475 1565 1675 1755 1885 1970 2085 2145 2185 2315 865 935 1025 1115 1220 1295 1365 1495 1580 1680 1735 1770 1880 1985 2080 2185 2285 2425 720 800 870 970 1060 1145 1250 1345 1435 1545 1645 1740 1830 2015 2035 2140 2230 2425

Air Delivery - CFM (with filter) (Continued)

0.2 630 735 835 925 1040 1140 1230 1320 1425 1520 1625 1710 1840 1925 2045 2105 2145 2280 765 835 945 1035 1150 1230 1305 1435 1525 1625 1685 1720 1830 1935 2040 2150 2245 2375 610 695 770 880 975 1070 1175 1280 1370 1485 1590 1685 1775 1965 1990 2095 2190 2385

0.3 540 650 760 855 975 1080 1175 1265 1375 1470 1580 1665 1795 1885 2005 2070 2105 2240 655 735 845 945 1075 1160 1235 1380 1465 1575 1630 1670 1785 1890 1995 2105 2205 2335 490 590 675 785 890 985 1105 1205 1305 1425 1530 1635 1725 1920 1940 2050 2150 2340

External Static Pressure (IN.W.C.)

0.4

0.5

0.6

0.7

450

375

285

205

570

490

415

345

680

605

535

465

780

710

640

575

910

845

780

710

1020

955

895

835

1120

1065

1005

945

1215

1160

1105

1050

1325

1275

1220

1170

1425

1375

1330

1280

1535

1490

1450

1400

1625

1580

1535

1490

1755

1715

1670

1630

1845

1805

1765

1725

1960

1925

1885

1845

2030

1990

1955

1920

2070

2035

1995

1960

2200

2145

2090

2035

560

450

355

270

640

540

440

350

755

670

575

475

855

775

695

600

985

905

830

755

1075

995

920

850

1160

1080

1010

940

1315

1245

1170

1105

1410

1345

1275

1200

1520

1460

1395

1325

1580

1525

1465

1400

1620

1565

1510

1445

1735

1685

1635

1580

1845

1800

1755

1705

1950

1910

1865

1820

2065

2030

1985

1945

2165

2130

2090

2050

2285

2240

2195

2145

390

290

205

110

480

390

300

220

570

475

395

310

700

605

525

440

805

725

635

555

905

830

750

665

1025

955

880

805

1135

1065

1000

930

1240

1170

1105

1045

1360

1300

1235

1175

1475

1415

1350

1295

1580

1525

1465

1410

1675

1620

1565

1510

1870

1825

1775

1725

1895

1850

1805

1760

2005

1960

1915

1875

2110

2070

2025

1985

2290

2240

2190

2135

0.8 130 265 400 510 650 770 885 995 1115 1230 1355 1450 1590 1685 1810 1885 1925 1980 185 270 395 510 665 775 870 1040 1140 1260 1335 1380 1520 1655 1775 1900 2015 2095
135 235 365 485 595 730 860 980 1115 1240 1355 1455 1680 1710 1830 1945 2080

0.9 -
190 330 445 585 710 825 935 1060 1175 1305 1405 1550 1645 1775 1845 1885 1925
190 320 430 580 690 795 975 1080 1205 1275 1320 1460 1595 1720 1855 1975 2045
155 290 410 525 660 785 910 1050 1180 1300 1405 1630 1660 1785 1905 2025

1 135 255 385 530 655 770 880 1010 1125 1255 1360 1505 1610 1735 1805 1850 1870 245 360 495 610 710 910 1020 1145 1220 1270 1400 1535 1665 1810 1935 1990 230 345 455 595 725 845 990 1125 1250 1355 1580 1615 1740 1860 1965

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8

59SC6A: Product Data

Air Delivery - CFM (with filter) (Continued)

Unit Size 140M24--22

Airflow Setting
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Default Setting Cont. Fan
Heat Cooling

0.1 795 900 960 1050 1160 1260 1355 1445 1545 1650 1740 1840 1940 2050 2095 2150 2255 2420

0.2 685 795 865 960 1075 1180 1285 1375 1480 1585 1680 1785 1885 1995 2040 2100 2205 2370

0.3 585 700 775 870 985 1100 1205 1300 1415 1520 1620 1725 1830 1945 1990 2050 2155 2325

External Static Pressure (IN.W.C.)

0.4

0.5

0.6

0.7

475

380

290

205

605

505

420

340

685

590

500

420

785

700

610

530

910

835

755

670

1020

950

880

800

1130

1060

995

925

1230

1160

1095

1035

1345

1280

1220

1155

1460

1395

1330

1275

1560

1500

1435

1380

1670

1615

1555

1500

1775

1720

1670

1610

1890

1840

1790

1735

1940

1890

1840

1790

2000

1950

1905

1855

2110

2060

2015

1965

2280

2230

2165

2095

0.8 135 260 345 455 590 720 855 970 1095 1215 1320 1445 1555 1680 1735 1800 1915 2025

0.9 -
180 265 385 525 650 775 895 1035 1155 1265 1390 1505 1630 1680 1745 1860 1955

1 195 315 455 585 705 825 965 1100 1210 1340 1450 1575 1630 1695 1810 1880

NOTE:
1. A filter is required for each return-air inlet. Airflow performance included 3/4-in. (19 mm) washable filter media such as contained in a factory - authorized accessory filter rack. See accessory list. To determine airflow performance without this filter, assume an additional 0.1 in. w.c. available external static pressure.
2. Adjust the blower airflow setting as necessary for the proper air temperature rise for each installation. 3. Airflows over 1800 CFM require bottom return, two-side return, or bottom and side return. A minimum filter size of 20" x 25" (508 x 635 mm) is required. 4. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return 5. The -- entry indicates unstable operating conditions

Airflow Settings

Default Airflow Settings*

Designated Airflow Settings

Unit Size

Heating

Cooling

Heating

Constant Fan

026M14--10

6

18

(5-14)

(1-7)

040M14--10

9

18

(6-11)

(1-1)

040M17--12

8

18

(5-9)

(1-5)

060M14--12

12

18

(9-12)

(1-3)

060M17--16

9

18

(5-10)

(1-7)

080M17--16

12

18

(7-13)

(1-1)

080M21--20

9

17

(5-11)

(1-8)

100M21--20

12

18

(10-12)

(1-4)

100M21--22

11

17

(8-14)

(1-7)

120M24--22

14

18

(11-14)

(1-3)

140M24--22

15

18

(10-15)

(1-1)

*. Setting #1 is the default setting for Constant Fan

TYPICAL WIRING SCHEMATIC

FURNACE CONTROL BOARD

FIELD 24-V WIRING FIELD 115-, 208/230-, 460-V WIRING FACTORY 24-V WIRING FACTORY 115-V WIRING

NOTE 2

FIVE WIRE

WCR

THREE-WIRE HEATING-ONLY

BLOWER DOOR SWITCH

G

Y

THERMOSTAT TERMINALS

BLK

BLK

W

FIELD-SUPPLIED DISCONNECT
208/230- OR 460-V THREE PHASE

WHT

WHT

CR O

N

GND

GND

T

115-V FIELD- AUXILIARY SUPPLIED J-BOX

RG
O L COM

DISCONNECT

Y

24-V TERMINAL
BLOCK
FURNACE

NOTE 1

GND
CONDENSING UNIT
TWO WIRE

208/230-V SINGLE PHASE

NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation. 2. Some thermostats require a "C" terminal connection as shown. 3. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire.

A190079

A210192

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 9

59SC6A: Product Data

MAXIMUM ALLOWABLE EXPOSED VENT LENGTH

Maximum Allowable Exposed Vent Lengths in Unconditioned Space Insulation Table - Ft.

Winter Design Temp
°F

Unit Size
Pipe Dia. in.
20 0 -20 -40

Uninsulated

1 ½

2

20

20

5

5

26,000* BTUH 3/8-in. Insulation 1/2-in. Insulation

1 ½

2

1 ½

2

50

45

60

50

25

20

30

25

15

10

20

15

10

5

15

10

Winter Design Temp °F

Unit Size
Pipe Dia. in. 20 0 20 40

Uninsulated

40,000* BTUH
3/8in. Insulation

1/2in. Insulation

1½ 2 2½ 1½ 2 2½ 1½ 2 2½

20 20 20 20 50 45 20 60 50

10 5 5 20 25 20 20 30 25

5

20 15 10 20 20 15

15 10 5 15 15 10

Uninsulated

60,000 BTUH 3/8in. Insulation

1/2in. Insulation

1½ 2 2½ 3 1½ 2 2½ 3 1½ 2 2½ 3

20 30 30 25 20 75 65 60 20 85 75 65

15 15 10 10 20 40 30 25 20 45 40 30

10 5

20 25 20 15 20 30 25 20

5

20 15 15 10 20 20 15 10

Unit Size

Uninsulated

80,000 BTUH 3/8in. Insulation

1/2in. Insulation

Winter Pipe Dia. in. 1 ½

2

2 ½

3

4

1 ½

2

2 ½

3

4

1 ½

2

2 ½

3

4

Design

20

15

40

40

35

30

15

50

90

75

65

15

50

70

70

70

Temp °F

0

15

20

15

10

5

15

50

45

35

30

15

50

50

40

35

20

15

10

5

15

35

30

20

15

15

40

30

25

15

40

10

5

15

25

20

15

5

15

30

25

20

10

Winter Design Temp °F

Unit Size
Pipe Dia. in. 20 0 20 40

Uninsulated
2 2½ 3 4
20 50 40 35 20 20 15 10 15 10 5 10 5

100,000 BTUH 3/8in. Insulation
2 2½ 3 4
20 80 95 80 20 55 45 35 20 35 30 20 20 25 20 10

1/2in. Insulation
2 2½ 3 4
20 80 105 90 20 65 55 45 20 45 35 25 20 30 25 15

Uninsulated
2½ 3 4
10 50 40 10 20 15 10 10 10 5

120,000 BTUH 3/8in. Insulation 1/2in. Insulation

2½ 3 4 2½ 3

4

10 75 95 10 75 105 10 55 45 10 65 50 10 35 25 10 45 30 10 25 15 10 30 20

Winter Design Temp °F

Unit Size
Pipe Dia. in. 20 0 20 40

Uninsulated
2½ 3 4
5 55 50 5 25 15 5 10 5 55

*. Not all model families have this size.

140,000* BTUH
3/8-in. Insulation 1/2-in. Insulation
2½ 3 4 2½ 3 4
5 65 105 5 65 125 5 65 50 5 65 60 5 45 30 5 50 40 5 30 20 5 35 25

Winter Design Temp
°C

Maximum Allowable Exposed Vent Length in Unconditioned Space - Meters

Unit Size
Pipe Dia. mm
-7 -18 -29 -40

Uninsulated

38

51

6.1

6.1

1.5

1.5

26,000* BTUH 3/8-in. Insulation 1/2-in. Insulation

38

51

38

51

15.2

13.7

18.3

15.2

7.6

6.1

9.1

7.6

4.6

3.0

6.1

4.6

3.0

1.5

4.6

3.0

Winter Design Temp °C

Unit Size

Uninsulated

Pipe Dia. mm

38

51

64

-7

6.1 6.1 6.1

-18 3.0 1.5 1.5

-29 1.5

-40

40,000 BTUH
3/8in. Insulation

1/2in. Insulation

38 51 64 38 51 64

6.1 15.2 13.7 6.1 18.3 15.2 6.1 7.6 6.1 6.1 9.1 7.6 6.1 4.6 3.0 6.1 6.1 4.6 4.6 3.0 1.5 4.6 4.6 3.0

Uninsulated

60,000 BTUH 3/8in. Insulation

1/2in. Insulation

38 51 64 76 38 51 64 76 38 51 64 76

6.1 9.1 9.1 7.6 6.1 22.9 19.8 18.3 6.1 25.9 22.9 19.8

4.6 4.6 3.0 3.0 6.1 12.2 9.1 7.6 6.1 13.7 12.2 9.1

3.0 1.5

6.1 7.6 6.1 4.6 6.1 9.1 7.6 6.1

1.5

6.1 4.6 4.6 3.0 6.1 6.1 4.6 3.0

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10

59SC6A: Product Data

Unit

80,000 BTUH

Size

Uninsulated

3/8in. Insulation

1/2in. Insulation

Winter Design Temp °C

Pipe Dia. mm
-7 -18

38
4.6 4.6

51

64

76 102

12.2 12.2 10.7 9.1 6.1 4.6 3.0 1.5

38
4.6 4.6

51

64

76 102

15.2 27.4 22.9 19.8 15.2 13.7 10.7 9.1

38
4.6 4.6

51

64

76 102

15.2 21.3 21.3 21.3 15.2 15.2 12.2 10.7

-29

4.6 3.0 1.5

4.6 10.7 9.1 6.1 4.6 4.6 12.2 9.1 7.6 4.6

-40

3.0 1.5

4.6 7.6 6.1 4.6 1.5 4.6 9.1 7.6 6.1 3.0

Winter Design Temp
°C

Unit Size
Pipe Dia. mm -7 -18 -29 -40

Uninsulated

100,000 BTUH 3/8in. Insulation

1/2in. Insulation

51 64 76 102 51 64 76 102 51 64 76 102

6.1 15.2 12.2 10.7 6.1 24.4 28.9 24.4 6.1 24.4 32.0 27.4

6.1 6.1 4.6 3.0 6.1 16.8 13.7 10.7 6.1 19.8 16.7 13.7

4.6 3.0 1.5

6.1 10.7 9.1 6.1 6.1 13.7 10.7 7.6

3.0 1.5

6.1 7.6 6.1 3.0 6.1 9.1 7.6 4.6

Uninsulated

120,000 BTUH
3/8in. Insulation

1/2in. Insulation

64 76 102 64 76 102 64 76 102

3.0 15.2 12.2 3.0 22.9 28.9 3.0 22.9 32.0

3.0 6.1 4.6 3.0 16.8 13.7 3.0 19.8 15.2

3.0 3.0

3.0 10.7 7.6 3.0 13.7 9.1

3.0 1.5

3.0 7.6 4.6 3.0 9.1 6.1

Winter Design Temp
°C

Unit Size
Pipe Dia. mm -7 -18 -29 -40

Uninsulated

140,000* BTUH* 3/8-in. Insulation 1/2-in. Insulation

64 76 102 64 76 102 64 76 102

1.5 16.7 15.2 1.5 19.8 32.0 1.5 19.8 38.1

1.5 7.6 4.6 1.5 19.8 15.2 1.5 19.8 18.3

1.5 3.0 1.5 1.5 13.7 9.1 1.5 15.2 12.2

1.5 1.5

1.5 9.1 6.1 1.5 35 7.6

*. Not all model families have this size.

MAXIMUM EQUIVALENT VENT LENGTH - Ft. (M)

NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Deductions

from Maximum Equivalent Vent Length to determine allowable vent length for each application.

Unit Size

Pipe Dia. (in)
0-2000
2001-3000

3001-4000

Altitude (feet)

4001-4500 4501-5000 5001-6000 6001-7000 7001-8000

8001-9000

9001-10000

26,000 2
1½ 2
70 200 65 190 60 175 55 160
50 145 45 135 40 120 35 110 30 95

40,000 1

1½ 2 2½

40 155 185

35 150 175

30 135 160

25

130 125

155 145

20 120 130

15 110 120

10

100 90

110 95

5 80 85

Unit Size
Pipe Dia. (mm) 0-610
611-914 915-1219 Altitude 1220-1370 (meters) 1371-1524 1525-1829 1830-2134 2135-2438 2439-2743 2744-3048

26,000 2

40,000 1

38 51 38 51 64

21.3 60.9 12.1 47.2 56.3

19.8 57.9 10.6 45.7 53.3

18.2 53.3 9.1 41.1 48.7

16.7 48.7 7.6

39.6 38.1

47.2 44.1

15.2 44.1 6.0 36.5 39.6

13.7 41.1 4.5 33.5 36.5

12.1 36.5 10.6 33.5

3.0

30.4 27.4

33.5 28.9

9.1 28.9 1.5 24.3 25.9

60,000 2

80,000

100,000 3

120,000

140,000 3

1 ½

2

2 ½

3 1½ 2 2½ 3

4 2 2½ 3

4 2½ 3

4 2½ 3

4

20

100 95

175 165

200 185

15

16 90 155 175

85 150 170 10

15 80 145 165

75 140 155

13 70 130 145

10 65 120 135

55 49
44 41 38 36

130 175 200 20

125 115

165 155

185 175

15

110 100

150 145 135

165 160 150

10

90

125 140 120 125

80 75 70 65 60 55

175 200 165 185

10

75 70

155

175 170

5

65

150 165

60

140 155

135 125

145 135

N/A

50 46

185 5 65

175

60

165

160

50 45

155 140

N/A

35 30

130

25

155 140 120 110 100 80 65 45

5 60 115 125 N/A 33 80 110 115 N/ 50 115 125

43 120

15 30

N/ A

55

105 115

30 75 100 105 A 45 100 115

39 115

10 15

Maximum Equivalent Vent Length - Meters

60,000 2

80,000

100,000 3

120,000

140,000 3

38 51 64 76 38 51 64 76 102 51 64 76 102 64 76 102 64 76 102

6.0

30.4 28.9

53.3 50.2

60.9 56.3

4.8 27.4 47.2 53.3

25.9 45.7 51.8

4.5 24.3 44.1 50.2

22.8 42.6 47.2

4.5 16.7 39.6 53.3 60.9 6.0 24.3 53.3 60.9

3.0

14.9
13.4 12.4

38.1 35.0
33.5
30.4

50.2 47.2 45.7 44.1 41.1

56.3 53.3 50.2 48.7 45.7

4.5 3.0

22.8 21.3 19.8

50.2
47.2
45.7 42.6

56.3 53.3 51.8 50.2 47.2

3.0 1.5

22.8 56.3 1.5 21.3 53.3 19.8 50.2
18.2 48.7 47.2 NA

19.8 47.2 18.2 42.6
36.5 15.2 33.5 13.7 30.4 10.6 24.3

3.9 3.0 1.5

21.3 19.8 18.2

39.6 36.5 35.0

44.1 41.1 38.1

NA

11.5 10.9

27.4

38.1 36.5

42.6 38.1

18.2 41.1 44.1 16.7 38.1 41.1

10.0 24.3 33.5 35.0 NA 15.2 35.0 38.1

NA

15.2 42.6 14.0 39.6 13.1 36.5

9.1 19.8 7.6 13.7 4.5 9.1

NA 16.7 32.0 35.0

9.1 22.8 30.4 32.0

13.7 30.4 35.0

11.8 35.0

3.0 4.5

1. 40K Inducer Outlet Restrictor disk (P/N 337683-401; 1.25-in. (32 mm) Dia.) shipped in the loose parts bag or available through Replacement Components required under 10-ft. (3 M) TEVL in all orientations. Required for installations from 0 - 2000 ft. (0 to 610 M) above sea level. Failure to use an outlet restrictor may result in flame disturbances or flame sense lock-out.
2. 26K (shipped in loose parts bag) & 60K Inducer Outlet Restrictor disk (P/N 337683-401; 1.25-in. (32 mm) Dia. available through Replacement Components) required for less than 5-ft. (1.5 M) TEVL in downflow and horizontal orientations only. Required for installations from 0 - 2000 ft. (0 to 610 M) above sea level.
3. 120K & 140K Inducer Outlet Restrictor disk (P/N 337683-402; 1.50-in. (38 mm) Dia. available through Replacement Components) required for less than 5-ft. (1.5 M) TEVL in downflow and horizontal orientations only. Required for installations from 0 - 2000 ft. (0 to 610 M) above sea level.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 11

59SC6A: Product Data

ELBOW CONFIGURATIONS

VENT TERMINAL CONFIGURATIONS

Long

Medium

Mitered

Concentric

Standard 2-in., 3-in., or optional 4-in. termination.
Deductions from Maximum Equivalent Vent Length - Ft. (M)

A13110

Pipe Diameter (in): Mitered 90º Elbow Medium Radius 90º Elbow Long Radius 90º Elbow Mitered 45º Elbow Medium Radius 45º Elbow Long Radius 45º Elbow Tee Concentric Vent Termination Standard Vent Termination

1-1/2

8

(2.4)

5

(1.5)

3

(0.9)

4

(1.2)

2.5

(0.8)

1.5

(0.5)

16

(4.9)

NA

0

(0.0)

2

8

(2.4)

5

(1.5)

3

(0.9)

4

(1.2)

2.5

(0.8)

1.5

(0.5)

16

(4.9)

0

(0.0)

0

(0.0)

2-1/2

8

(2.4)

5

(1.5)

3

(0.9)

4

(1.2)

2.5

(0.8)

1.5

(0.5)

16

(4.9)

NA

0

(0.0)

3

8

(2.4)

5

(1.5)

3

(0.9)

4

(1.2)

2.5

(0.8)

1.5

(0.5)

16

(4.9)

0

(0.0)

0

(0.0)

NOTE:
1. Use only the smallest diameter pipe possible for venting. Over-sizing may cause flame disturbance or excessive vent terminal icing or freeze-up. 2. NA - Not allowed. Pressure switch will not close, or flame disturbance may result. 3. Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by local authorities having jurisdiction. 4. Size both the combustion air and vent pipe independently, then use the larger size for both pipes. 5. Assume the two 45_ elbows equal one 90_ elbow. Wide radius elbows are desirable and may be required in some cases. 6. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count. 7. The minimum pipe length is 5 ft. (2 M) linear feet (meters) for all applications. 8. Use 3-in. (76 mm) diameter vent termination kit for installations requiring 4-in. (102 mm) diameter pipe

4

8

(2.4)

5

(1.5)

3

(0.9)

4

(1.2)

2.5

(0.8)

1.5

(0.5)

16

(4.9)

NA

0

(0.0)

Venting System Length Calculations

The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Deductions from Maximum Equivalent Vent Length - Ft. (M) Table.

Standard vent terminations or factory accessory concentric vent terminations count for zero deduction.

See vent system manufacturer's data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that one foot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe.

Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Maximum Equivalent Vent Length Table.

Example 1

A direct-vent 60,000 BTUH furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE: 70 feet (22 M) of vent pipe, 65 feet (20 M) of combustion air inlet pipe, (3) 90º long-radius elbows, (2) 45º long-radius elbows, and a factory accessory concentric vent kit.

Can this application use 2" (50 mm ND) PVC/ABS DWV vent piping?

Measure the required linear length of air inlet and vent

pipe; insert the longest of the two here

Add equiv length of (3) 90º long-radius elbows (use the highest number of elbows for either the vent or inlet pipe)

3x

3 ft. (0.9 M)

=

Add equiv length of (2) 45º long-radius elbows (use the highest number of elbows for either the vent or inlet pipe)

2x

1.5 ft. (0.5 M)

=

Add equiv length of factory concentric vent term

Add correction for flexible vent pipe, if any

Total Equivalent Vent Length (TEVL)

70 ft. (22 M)
9 ft. (2.7 M)
3 ft. (0.9 M)
0 ft.
0 ft. 82 ft. (25 M)

Use length of the longer of the vent or air inlet piping system
From Deductions from Maximum Equivalent Vent Length - Ft. (M) Table.
From Deductions from Maximum Equivalent Vent Length - Ft. (M) Table.
From Deductions from Maximum Equivalent Vent Length - Ft. (M) Table. From Vent Manufacturer's instructions; zero for PVC/ABS DWV
Add all of the above lines

Maximum Equivalent Vent Length (MEVL) Is TEVL less than MEVL?

95 ft. (29 M) YES

For 2" pipe from Maximum Equivalent Vent Length Table. Therefore, 2" pipe MAY be used

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 12

59SC6A: Product Data

Example 2

A direct-vent 60,000 BTUH furnace installed at 2100 ft. (640M). Venting system includes FOR EACH PIPE: 100 feet (30 M) of vent pipe, 95 feet (29 M) of combustion air inlet pipe, (3) 90º long-radius elbows, and a polypropylene concentric vent kit. Also includes 20 feet (6.1 M) of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe.

VERIFY FROM POLYPROPYLENE VENT MANUFACTURER'S INSTRUCTIONS for the multiplier correction for flexible vent pipe.

Can this application use 60mm o.d. (2") polypropylene vent piping? If not, what size piping can be used?

Measure the required linear length of RIGID air inlet and vent pipe; insert the longest of the two here: 100 ft. Of rigid pipe - 20 ft. Of flexible pipe

=

80 ft. Use length of the longer of the vent (24 M) or air inlet piping system

Add equiv length of (3) 90º long-radius elbows (use the highest number of elbows for either the vent or inlet pipe)

3

x

5 ft. (1.5 M)

=

15 ft. (4.6 M)

Add equiv length of 45º long-radius elbows

(use the highest number of elbows for either the vent or

0

x

inlet pipe)

=

0 ft. (0 M)

Example from polypropylene vent manufacturer's instructions, Verify from vent

Add equiv length of factory concentric vent term

9

x

3.3 ft (0.9 M)

=

30 ft. (9 M)

manufacturer's instructions.

Add correction for flexible vent pipe, if any

2*

x

20 ft. (6.1 M)

=

40 ft. (12.2 M)

* VERIFY FROM VENT MANUFACTURER'S INSTRUCTIONS; For example only, assume 1 meter of flexible 60mm (2") or 80mm (3") polypropylene

pipe equals 2.0 meters (6.5 ft.) of PVC/ABS pipe.

Total Equivalent Vent Length (TEVL)

165 ft. (50 M)

Add all of the above lines

Maximum Equivalent Vent Length (MEVL) Is TEVL less than MEVL?

95 ft. (29 M)
NO

For 2" pipe from Maximum Equivalent Vent Length Table. Therefore, 60mm (2") pipe may NOT be used; try 80mm (3")

Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
RETURN AIR TEMPERATURE
This furnace is designed for continuous return-air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return-air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.

185 ft. (57 M) YES

For 3" pipe from Maximum Equivalent Vent Length Table. Therefore, 80mm (3") pipe MAY be used

COMBUSTION-AIR PIPE FOR NON-DIRECT (1-PIPE) VENT APPLICATION

FIELD-SUPPLIED 2-IN. (51 mm) DIA. MITERED RADIUS PVC 90° ELBOW

FIELD-SUPPLIED 2-IN. (51 mm) DIA. PVC PIPE

SUPPLY AIR

80 / 27°C

60 / 16°C

A10490
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

POSITION Rear
Front (Combustion air openings in furnace and in structure) Required for service*
All Sides of Supply Plenum* Sides Vent
Top of Furnace

CLEARANCE 0 (0 mm)
1 in. (25 mm)
24 in. (610 mm) 1 in. (25 mm) 0 (0 mm) 0 (0 mm) 1 in. (25 mm)

*. Consult your local building codes . Recommended

12" (300 mm) MINIMUM
A12376
NOTE: See Installation Instructions for specific venting configurations.
DOWNFLOW SUBBASE
1 1/4-IN. TYP PLENUM OPENING
A

FACTORY-SUPPLIED FIELD-INSTALLED INSULATION

C
A97427

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 13

59SC6A: Product Data
LOCATING TAB
B
D
LOCATING TAB

1234

4321

A88207

Downflow Subbase
A88202
One base fits all furnace sizes. The base is designed to be installed between the furnace and a combustible floor when no coil box is used or when a coil box other than a Carrier cased coil is used. It is CSA design certified for use with Carrier branded furnaces when installed in downflow applications.

FURNACE CASING WIDTH 14-3/16 (360) 17-1/2 (445) 21 (533) 24-1/2 (622)

DIMENSIONS (IN. / MM)

PLENUM OPENING*

FURNACE IN DOWNFLOW APPLICATION

A

B

Furnace with or without Cased Coil Assembly or Coil Box Furnace with or without Cased Coil Assembly or Coil Box Furnace with or without Cased Coil Assembly or Coil Box Furnace with or without Cased Coil Assembly or Coil Box

11-3/16 (322) 15-1/8 (384) 18-5/8 (396) 22-1/8 (562)

19 (483) 19 (483) 19 (483) 19 (483)

FLOOR OPENING

C

D

13-7/16 (341) 16-3/4 (426) 20-1/4 (514) 23-3/4 (603)

20-5/8 (600) 20-5/8 (600) 20-5/8 (600) 20-5/8 (600)

HOLE NO. FOR WIDTH
ADJUSTMENT 4 3 2 1

*. The plenum should be constructed 1/4-in. (6 mm) smaller in width and depth than the plenum dimensions shown above.

MEDIA FILTER CABINET (OPTIONAL ACCESSORY)

Concentric Vent Kit
A93086
A concentric vent kit allows vent and combustion-air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn in through the outer pipe.

23-5/8" (600mm) 23-3/8" (594mm)
Furnace Side

25-5/8" (651mm) 24-1/4" (616mm) Opening with Flanges Bent
23-1/8" (588mm) Opening
A
Duct Side

B Opening

23-3/4" (603mm)
Centerline Screw Slots

53 4" (146mm)

Media Filter Cabinet

A

B

16" (406mm) 17" (432mm) 16" (406mm)

20" (508mm) 21" (533mm) 20" (508mm)

24" (610mm) 25" (635mm) 24" (610mm)

NOTE: Media cabinet is matched to the bottom opening on furnace. May also be used for side return. A12428

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 14

ACCESSORIES

PART NUMBER P908-0001* 92-1003*
ACG1425NCB* ACG1625NCF*
325531-402* KGADA0101ALL KGADA0201ALL KGADA0301ALL KGARP0301B14 KGARP0301B17 KGAVT0701CVT KGAVT0801CVT KGAVT0101BRA KGAVT0201BRA KGADC0101BVC KGAAC0101RVC KGACK0101HCK KGAHT0101CFP KGAHT0201CFP KGAAD0110PVC KGAET0201ETK KGASB0201ALL
KGAAD0101MEC
KGAAD0201MEC
AGAGCANPL01B
AGAGCAPNL01B AGAGC9NPS01C* AGAGC9PNS01C* AGAGCAMHC01A AGATWNDTE01A

DESCRIPTION Condensate Neutralizer Kit
Gas Valve Tower Port Adapter Kit
External Filter Rack, 14-1/2 x 25"
External Filter Rack, 16 x 25"
Washable filter, 3/4" x 16" x 25" Coil Adapter Kits - No Offset
Coil Adapter Kits - Single Offset Coil Adapter Kits - Double Offset Return Air Base (Upflow Applications) 14.0-in. wide Return Air Base (Upflow Applications) 17.5-in. wide Vent Terminal - Concentric - 2" (51 mm) Vent Terminal - Concentric - 3" (76 mm) Vent Terminal Bracket - 2" (51 mm) Vent Terminal Bracket - 3" (76 mm) Vent Kit - Through the Cabinet for HZ left/right ONLY Polypropylene Inlet Air Pipe Coupling Horizontal Trap Grommet - Direct Vent Freeze Protect Kit - Condensate Drain Line Tape Freeze Protect Kit - Condensate Trap with Heat Pad CPVC to PVC Drain Adapters - 1/2" CPVC to 3/4" PVC
External Trap Kit Downflow Furnace Base Kit for Combustible Floors IAQ Device Duct Adapters 20.0-in. IAQ to 16 in. Side
Return IAQ Device Duct Adapters 24.0-in. IAQ to 16 in. Side
Return Gas Conversion Kit - Nat to LP Gas Conversion Kit - LP to Nat Gas Conversion Kit - Nat to LP Gas Conversion Kit - LP to Nat Manufactured Home Kit - Gas Conversion Twinning Kit - (MCT) ECM Motor

*. Purchased through Replacement Components . Factory-authorized and field installed. Fuel conversion kits are CSA recognized. X = Accessory

026M14-10 040M1410 040M1712 060M1412 060M17--16

X

X

X

X

X

X

X

X

X

X

X

X

-

X

-

-

-

X

-

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

-

X

-

-

-

X

-

X

See Venting Tables

X

X

X

X

X

X

X

X

X

X

All 2-Pipe Horizontal

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

20"x25" IAQ Devices

24"x25" IAQ Devices

X

-

-

-

-

X

-

-

-

-

-

X

X

X

X

-

X

X

X

X

-

X

X

X

X

-

-

-

-

X

59SC6A: Product Data

ACCESSORIES (continued)

PART NUMBER P908-0001* 92-1003*
ACG1625NCF* ACG2025NCJ* ACG2424NCL*
325531-402 325531-403 325531-404 KGADA0101ALL KGADA0201ALL KGADA0301ALL
KGARP0301B17
KGARP0301B21
KGARP0301B24
KGAVT0701CVT KGAVT0801CVT KGAVT0101BRA KGAVT0201BRA
KGADC0101BVC
KGAAC0101RVC KGACK0101HCK
KGAHT0101CFP
KGAHT0201CFP
KGAAD0110PVC
KGAET0201ETK
KGASB0201ALL
KGAAD0101MEC
KGAAD0201MEC
AGAGC9NPS01C* AGAGC9PNS01C* AGAGCAMHC01A AGATWNDTE01B

DESCRIPTION
Condensate Neutralizer Kit
Gas Valve Tower Port Adapter Kit
External Filter Rack, 16 x 25"
External Filter Rack, 20 x 25"* External Filter Rack, 24-1/2 x 24"* Washable filter, 3/4" x 16" x 25"* Washable filter, 3/4" x 20" x 25"* Washable filter, 3/4" x 24" x 25"*
Coil Adapter Kits - No Offset Coil Adapter Kits - Single Offset Coil Adapter Kits - Double Offset Return Air Base (Upflow Applications) 17-1/2"
wide Return Air Base (Upflow Applications) 21"
wide Return Air Base (Upflow Applications) 24-1/2
wide Vent Terminal - Concentric - 2" (51 mm) Vent Terminal - Concentric - 3" (76 mm)
Vent Terminal Bracket - 2" (51 mm) Vent Terminal Bracket - 3" (76 mm) Vent Kit - Through the Cabinet for HZ left/right
ONLY Polypropylene Inlet Air Pipe Coupling Horizontal Trap Grommet - Direct Vent Freeze Protect Kit - Condensate Drain Line
Tape Freeze Protect Kit - Condensate Trap with
Heat Pad CPVC to PVC Drain Adapters - 1/2" CPVC to
3/4" PVC External Trap Kit Downflow Furnace Base Kit for Combustible
Floors IAQ Device Duct Adapters 20" IAQ to 16" Side
Return IAQ Device Duct Adapters 24" IAQ to 16" Side
Return Gas Conversion Kit - Nat to LP Gas Conversion Kit - LP to Nat Manufactured Home Kit - Gas Conversion Twinning Kit - (MCT) ECM Motor

080M1716 X X X X X X X X -
X X
X X X X X
X X X X

080M2120 100M2120 100M2122

X

X

X

X

X

X

-

-

-

X

X

X

-

-

-

-

-

-

X

X

X

-

-

-

X

X

X

X

X

X

X

X

X

-

-

-

X

X

X

-

-

-

See Venting Tables

X

X

X

X

X

X

All 2-Pipe Horizontal

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

20"x25" IAQ Devices

24"x25" IAQ Devices

X

X

X

X

X

X

X

X

X

X

X

-

120M2422 X X -
X X X X X X
X X
X X X X X
X X X X

140M2422 X X -
X X X X X X
X X
X X X X X
X X X

*. Purchased through Replacement Components . Factory-authorized and field installed. Fuel conversion kits are CSA recognized. X = Accessory

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 16

59SC6A: Product Data
ACCESSORIES (continued)

Carrier has a wide variety of thermostats for your system, please visit www.Carrier.com to see all thermostat and IAQ products.

DESCRIPTION Carrier Carbon Monoxide Alarm (10 pack) Carrier Infinity Air Purifier - 16x25 (407x635 mm) Carrier Infinity Air Purifier - 20x25 (508x635 mm) Carrier Infinity Air Purifier Repl. Filter- 16x25 (407x635 mm) Carrier Infinity Air Purifier Repl. Filter- 20x25 (508x635 mm) Cartridge Media Filter - 16" (407 mm) (MERV 11) Cartridge Media Filter - 16" (407 mm) (MERV 8) Cartridge Media Filter - 20" (508 mm) (MERV 8) Cartridge Media Filter - 20" (508 mm) (MERV11) Cartridge Media Filter - 24" (610 mm) (MERV 8) Cartridge Media Filter - 24" (610 mm) (MERV11) EZ Flex Cabinet Side or Bottom - 16" EZ Flex Cabinet Side or Bottom - 20" EZ Flex Replacement Filters 16" MERV 10 EZ Flex Replacement Filters 16" MERV 13 EZ Flex Replacement Filters 20" MERV 10 EZ Flex Replacement Filters 20" MERV 13 EZ Flex Replacement Filters 24" MERV 10 EZ Flex Replacement Filters 24" MERV 13 EZ-Flex Filter with End Caps - 16" (407 mm) (MERV 10) EZ-Flex Filter with End Caps - 16" (407 mm) (MERV 13) EZ-Flex Filter with End Caps - 20" (508 mm) (MERV 10) EZ-Flex Filter with End Caps - 20" (508 mm) (MERV 13) EZ-Flex Filter with End Caps - 24" (610 mm) (MERV 10) EZ-Flex Filter with End Caps - 24" (610 mm) (MERV 13) Media Filter Cabinet - 20" Media Filter Cabinet - 24" Media Filter Cabinet -16"

ACCESSORY COALMCCNRB02-A10
DGAPAXX1625 DGAPAXX2025 PGAPXCAR1625A02 PGAPXCAR2025A02 FILXXCAR0116 FILXXCAR0016 FILXXCAR0020 FILXXCAR0120 FILXXCAR0024 FILXXCAR0124 EZXCAB--0016 EZXCAB--0020 EXPXXFIL0016 EXPXXFIL0316 EXPXXFIL0020 EXPXXFIL0320 EXPXXFIL0024 EXPXXFIL0324 EXPXXUNV0016 EXPXXUNV0316 EXPXXUNV0020 EXPXXUNV0320 EXPXXUNV0024 EXPXXUNV0324 FILCABXL0020 FILCABXL0024 FILCABXL0016

14"

17"

21"

24"

X

X

X

X

X

X

-

-

-

-

X

X

X

X

-

-

-

-

X

X

X

X

-

-

X

X

-

-

-

-

X

-

-

-

X

-

-

-

-

X

-

-

-

X

X

X

-

-

-

-

X

X

X

X

-

-

X

X

-

-

-

-

X

-

-

-

X

-

-

-

-

X

-

-

-

X

X

X

-

-

X

X

-

-

-

-

X

-

-

-

X

-

-

-

-

X

-

-

-

X

-

-

X

-

-

-

-

X

X

X

-

-

© 2022 Carrier. All rights reserved.

Edition Date: 11/22

Catalog No: 59SC6A-01PD REV B

Replaces 59SC6A-01PD REV A

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

17

