Disclaimer
Please read the product documentation thoroughly and ensure you understand it before using the product. Improper use may cause serious injury, product damage, or property loss. Always refer to the most up-to-date documentation available at https://www.ecoflow.com/support/download/. This documentation takes precedence over all other versions. By using this product, you acknowledge and agree to all terms and conditions stated in the documentation. EcoFlow is not liable for losses caused by improper use or failure to adhere to the provided instructions. Subject to applicable laws and regulations, EcoFlow reserves the right to the final interpretation of this document and all documents related to the product.
Safety Instructions
CAUTION!
- Danger of electrocution. Mounting/installation of the device to the power grid has to be performed with caution by a qualified electrician.
- Danger of electrocution. Every change in the connections has to be done after ensuring there is no voltage present at device terminals.
- Use the device only with a power grid and appliances which comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the device may damage it.
- Do not connect the device to appliances exceeding the given max load!
- Connect the device only in the way shown in these instructions. Any other method could cause damage and/or injury.
- Do not install the device where it can get wet.
- Plug in or unplug the LAN cable only when the device is powered off! The LAN cable must not be metallic in the parts touched by the user to plug it in or unplug it.
- Do not allow children to play with the buttons/switch connected to the device. Keep the devices for remote control of EcoFlow products away from children.
- Only current transformers (CTs) compliant with local regulations and standards should be used with this device.
- Before operating the current transformer (CT), ensure that the power supply is completely disconnected and the circuit is de-energized.
- RECOMMENDATION: Connect the device using solid single-core cables with increased insulation heat resistance not less than PVCT105°C (221°F).
- The protection provided by the device may be impaired when the device is not used in accordance with the manufacturer's instructions.
- Indoor Use Only ?
Safety Symbols
CAUTION ⚠️
Disconnect the device from all voltage sources before servicing.
CAUTION! RISK OF ELECTRIC SHOCK ⚡
Do not remove the cover (or back). No user serviceable parts inside. Refer servicing to qualified service personnel.
READING MANUAL ?
Read the user manual and all safety instructions carefully before installation, operation, and maintenance.
DOUBLE INSULATION ?
Equipment protected throughout by double insulation or reinforced insulation.
Maintenance
- Periodically inspect and clean the device. As part of routine maintenance, regularly check the device status via the EcoFlow app or inspect the Power Status LED Indicator to ensure it is functioning normally. If the device is faulty, refer to the in-app instructions for troubleshooting or contact EcoFlow technical support.
- Clean the device surfaces with a dry cloth and keep them free from dust.
Disposal
- If the device cannot work anymore, dispose of it in accordance with the local disposal requirements for electrical equipment waste. The device cannot be disposed of together with household waste.
Technical Parameters
Parameter | Value |
---|---|
Model | EF-EM-P3-120 |
Dimensions | 90×66×36 mm (antenna included) |
Mounting | DIN rail |
Operating Temperature | -25°C to 70°C |
Storage Temperature | -40°C to 85°C |
Operating Altitude | ≤ 3000 m |
Relative Humidity | 5%-95% |
Voltage Input | 400V/230V 3N~, CAT III 300V |
Power Input | 100-276V~, 50/60Hz, < 3W |
Current Input | 48mA |
Conductor Cross-section | 0.5-2.5 mm² / 20-14AWG (solid wire, stranded wire, and ferrule) |
Conductor Stripping Length | 6-7 mm |
Pollution Degree | PD2 |
IP Rating | IP30 |
Compatible Current Transformer | 48mA, 0.1%In~In, 0.1%In |
Wi-Fi | Frequency: 2400-2495 MHz (for EU) Maximum Output Power: <20 dBm (for EU) |
Bluetooth | Frequency: 2402-2480 MHz (for EU) Maximum Output Power: <20 dBm (for EU) |
Introduction
The EcoFlow Smart Meter is a DIN rail mountable three-phase energy meter. It can be controlled and monitored through Wi-Fi connection. Bluetooth connection can be used for the inclusion process. The device reports accumulated energy as well as voltage, current, and power factor data in real-time. It stores data in non-volatile memory for later retrieval at least 60 days of 1 min data resolution.
Appearance
The EcoFlow Smart Meter has the following components:
- 1. Detachable antenna
- 2. Power Status Indicator
- 3. Wi-Fi Status Indicator
- 4. RS485 Status Indicator
- 5. Reset Button
- 6. Voltage L1 Input and Device Power Supply Input
- 7. Voltage L2 Input
- 8. Voltage L3 Input
- 9. Neutral Input
- 10. RS485 A (+) Terminal
- 11. RS485 B (−) Terminal
- 12. CT (Current Transformer) Port
- 13. External CT Cable
- 14. Extension Antenna
* Images are for demonstration purposes only. Refer to the actual product received.
Button and LED Indicators
Reset Button
- Press and hold for 5-10 seconds to start device pairing.
- Press and hold for over 10 seconds to restart the device.
Power Status Indicator
- Off: The device is powered off.
- Solid Green: The device is powered on and functioning normally.
- Solid Orange: Indicates one of the following conditions:
1. The current household load is too low to be measured.
2. The CT (Current Transformer) is not detected. Ensure the CT is properly installed and clamped.
Wi-Fi Status Indicator
- Off: The device is not connected to a wireless network.
- Solid green: The device is connected to the internet via a wireless network.
- Breathing green: The device is upgrading the firmware.
- Solid orange: The device is connected to a wireless network, but internet access is unavailable.
RS485 Status Indicator
- The RS485 terminals and LED indicator are reserved for factory use.
Installation
Mounting
CAUTION!
- For safety, turn off the relevant circuit breakers and verify zero voltage at their terminals using a phase tester or multimeter before beginning installation.
- Always wear appropriate insulating gloves during installation.
Mount the device onto the distribution box DIN rail and ensure it is securely fastened.
Diagram showing mounting the device on a DIN rail.
Antenna Replacement (If Necessary)
If the installation site has weak or unreliable wireless signal reception, replace the smart meter's antenna with the supplied extension antenna to improve performance.
Diagram showing antenna replacement.
Electrical Connection
Follow the diagrams below to complete the electrical connection.
Use as a Three-phase Smart Meter
Diagram illustrating the electrical connections for a three-phase setup.
Use as a Single-phase Smart Meter
Diagram illustrating the electrical connections for a single-phase setup.
Initial Inclusion
Download the EcoFlow app, register an account, log in, and follow the in-app instructions to bind the device. Once bound, you can monitor and control the device via the app.
QR code and app store download links are displayed.
WEEE Directive and CE Marking
WEEE DIRECTIVE ♻️
Do not dispose of the device as household waste. Follow local electronic waste disposal regulations.
CE Marking ✅
The device complies with the essential requirements of the relevant EU legislation.
EU Declaration of Conformity
EcoFlow Inc. declares that this product is in compliance with Directives 2014/35/EU, 2011/65/EU(RoHS), (EU) 2015/863(RoHS). The full text of the EU Declaration of Conformity is available at: http://www.ecoflow.com/eu/eu-compliance
Bluetooth®