RS-PWM30-40-50-60 Charge Controller

Rich Solar - Solar Charge Controller Model RS-PWM30P,RS-PWM40P, RS-PWM50P, RS-PWM60P User Manual

Component Manuals – Forest River Inc.

PDF preview unavailable. Download the PDF instead.

Rich Solar - Solar Charge Controller Model RS-PWM30P,RS-PWM40P, RS-PWM50P, RS-PWM60P User Manual
30A,40A,50A & 60A PWM SOLAR CHARGE CONTROLLER RS-PWM30P | RS-PWM40P | RS-PWM50P | RS-PWM60P
07

Rich Solar PWM Charge Controller Comparison ­ 30A / 40A / 50A / 60A

Controller Specifications

Model Rated Current

RS-PWM30P 30A

System Voltage

12V/24V (Auto)

Rated Power
No-load Loss
Max Solar Input Voltage Max Voltage at Battery End USB Function Bluetooth Operating Temp IP Rating Net Weight Dimensions (mm)

12V/450W 24V/900W <13mA/12V; <15mA/24V <55V <34V Yes Optional -25°C to +55°C IP30 390g 164×103.5×47.0

RS-PWM40P 40A 12V/24V/36V/48V (Auto) 12V/600W 24V/1200W <13mA/12V; <15mA/24V <55V <34V No ­ -25°C to +55°C IP30 650g 189.27×127.2×54.0

RS-PWM50P 50A 12V/24V/36V/48V (Auto) 12V/750W 24V/1500W <13mA/12V; <15mA/24V <55V <34V No ­ -25°C to +55°C IP30 650g 189.27×127.2×54.0

RS-PWM60P 60A 12V/24V/36V/48V (Auto) 12V/900W 24V/1800W <13mA/12V; <15mA/24V <55V <34V No ­ -25°C to +55°C IP30 650g 189.27×127.2×54.0

Battery Charging Parameters Battery Type
Over-voltage Protection Equalizing Charging Voltage Boost Charging Voltage Float Charging Voltage Charging Recovery Voltage Over-discharge Recovery Over-discharge Voltage Equalizing Interval Equalizing Time Boost Charge Time Temperature Compensation

Flooded (FLD) Sealed (SLD)

GEL

16.0V

16.0V

16.0V

14.8V

14.6V

­

14.6V

14.4V

14.2V

13.8V

13.8V

13.8V

13.2V

13.2V

13.2V

12.5V (Settable) ­

­

11.0V (Settable) ­

­

30 Days

­

­

1 Hour

­

­

2 Hours

­

­

-3.0mV/°C/2V ­

­

Lithium (LI)

Notes

16.0V

Default: SLD

­

14.4V

­

­

­

­

­

­

­

­

Lighting & Protection Features

Feature Light Control Voltage Light Control Delay Protection Functions

Details Light ON at 5V, OFF at 6V (ON = +1V) 10 minutes Battery reverse connection, solar panel reverse protection, reverse charging at night Charging overload, over-current, short circuit protection

Note 1 & 2: (RS-PWM30P) reverse connect panels, pleae do not connect battery at the same time; When battery reverse connect, please do not connect panels at the same time. Otherwise it may cause damage of controller.

