SZ21080255E01 BLU C5L MAX FCC EMC

BLU Products, Inc. BLUC5LMAX Smart Phone with GSM, WCDMA, LTE, Bluetooth and WiFi YHLBLUC5LMAX YHLBLUC5LMAX bluc5lmax

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=5520120
REPORT No.SZ21080255E01
TEST REPORT

APPLICANT

: BLU Products, Inc.

PRODUCT NAME : Smart Phone

MODEL NAME

: C5L MAX

BRAND NAME

: BLU

FCC ID

: YHLBLUC5LMAX

STANDARD(S) : 47 CFR Part 15 Subpart B

RECEIPT DATE : 2021-09-15

TEST DATE

: 2021-10-15 to 2021-10-21

ISSUE DATE

: 2021-10-26

Edited by: Approved by:

He Sinuo(Rapporteur) Xiao Xiong(Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page1of 20

REPORT No.SZ21080255E01
DIRECTORY
1. Technical Information········································································································3 1.1. Applicant and Manufacturer Information·····································································3 1.2. Equipment Under Test (EUT) Description ···································································3 2. Test Results ························································································································5 2.1. Applied Reference Documents ·····················································································5 2.2. EUT Setup and Operating Conditions··········································································6 3. 47 CFR Part 15B Requirements ·······················································································7 3.1. Conducted Emission ······································································································7 3.2. Radiated Emission········································································································11 Annex A Test Uncertainty ···································································································18 Annex B Testing Laboratory Information·········································································19

Issue 1.0

Change History Date 2021-10-26

Reason for change First edition

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page2of 20

1. Technical Information

REPORT No.SZ21080255E01

Note: Provide by applicant.
1.1. Applicant and Manufacturer Information

Applicant: Applicant Address: Manufacturer: Manufacturer Address:

BLU Products, Inc. 10814 NW 33rd St # 100 Doral, FL 33172,USA BLU Products, Inc. 10814 NW 33rd St # 100 Doral, FL 33172,USA

1.2. Equipment Under Test (EUT) Description

Product Name: EUT No.: Hardware Version: Software Version: Tx Frequency:
Rx Frequency:

Smart Phone
4#
A507-MB-V3.6
BLU_C0170WW_V11.0.G.02.00_GENERIC 22-09-2021 13:40 GSM850: 824 MHz ~ 849 MHz GSM1900: 1850 MHz ~ 1910 MHz WCDMA Band II: 1850 MHz ~ 1910 MHz WCDMA Band IV: 1710 MHz ~ 1755 MHz WCDMA Band V: 824 MHz ~ 849 MHz LTE Band 2: 1850 MHz ~ 1910 MHz LTE Band 4: 1710 MHz ~ 1755 MHz LTE Band 5: 824 MHz ~ 849 MHz LTE Band 7: 2500 MHz ~ 2570 MHz LTE Band 12: 699 MHz ~ 716 MHz LTE Band 17: 704 MHz ~ 716 MHz LTE Band 66: 1710 MHz ~ 1780 MHz Bluetooth: 2402 MHz ~ 2480 MHz 802.11b/g/n: 2412 MHz ~ 2472 MHz GSM850: 869 MHz ~ 894 MHz GSM1900: 1930 MHz ~ 1990 MHz WCDMA Band II: 1930 MHz ~ 1990 MHz WCDMA Band IV: 2110 MHz ~ 2155 MHz WCDMA Band V: 869 MHz ~ 894 MHz LTE Band 2: 1930 MHz ~ 1990 MHz LTE Band 4: 2110 MHz ~ 2155 MHz LTE Band 5: 869 MHz ~ 894 MHz LTE Band 7: 2620 MHz ~ 2690 MHz

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page3of 20

REPORT No.SZ21080255E01

Ancillary Equipment: Note:

LTE Band 12: 729 MHz ~ 746 MHz LTE Band 17: 734 MHz ~ 746 MHz LTE Band 66: 2110 MHz ~ 2200 MHz Bluetooth: 2402 MHz ~ 2480 MHz 802.11b/g/n: 2412 MHz ~ 2472 MHz Battery

Brand Name: BLU

Model No.:

C775444200L

Serial No.:

(N/A, marked #1 by test site)

Capacity:

2000mAh

Rated Voltage: 3.8V

Charge Limit: 4.35V

Manufacturer: Shenzhen Guihang Electronics Co., LTD

AC Adapter

Brand Name: BLU

Model No.:

US-FC-0750

Serial No.:

(N/A, marked #1 by test site)

Rated Input:

100-240V 50/60Hz, 0.2A

Rated Output: 5.0V 750mA

Manufacturer:

Dongguan Keling Electronic Technology Co., LTD

1. For a more detailed description, please refer to specification or user's manual supplied by the applicant and/or manufacturer.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page4of 20

2. Test Results

REPORT No.SZ21080255E01

2.1. Applied Reference Documents

The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

No.

Identity

1

47 CFR Part 15

Document Title Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:

No. Section Description
Conducted 1 15.107
Emission Radiated 2 15.109 Emission

Test Date

Test Engineer

Result

Method determination
Remark

2021.10.15 Su Zhan

PASS No deviation

2021.10.21 Lin Jiayong

PASS No deviation

Note 1:The tests were performed according to the method of measurements prescribed in ANSI C63.4-2014.

Note 2:Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table.

Note 3: When the test result is a critical value,we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page5of 20

REPORT No.SZ21080255E01
2.2. EUT Setup and Operating Conditions

Note: All of the following test modes are tested in all the test items.
Test Modes Mode 1 : GSM850 Idle + Bluetooth Idle + WLAN Idle + Battery + USB Cable(Charging from
Adapter) + Earphone + Adapter + SIM Card Mode 2 : GSM1900 Idle + Bluetooth Idle + WLAN Idle + Battery + USB Cable(Charging from
Adapter) + Earphone + Adapter + SIM Card Mode3 : WCDMA Band II Idle + Bluetooth Idle + WLAN Idle + Battery + USB Cable(Charging
from Adapter) + Earphone + Adapter + SIM Card Mode 4 : LTE Band 4 Idle + Bluetooth Idle + WLAN Idle + Battery + USB Cable(Charging from
Adapter) + Earphone + Adapter + SIM Card Mode 5 : WCDMA Band IV Idle + Bluetooth Idle + WLAN Idle + Battery + USB Cable(Charging
from Adapter) + Earphone + Adapter + SIM Card Mode 6 : WCDMA Band V Idle + Bluetooth Idle + WLAN Idle + Battery + USB Cable(Charging
from Adapter) + Earphone + Adapter + SIM Card Mode 7 : LTE Band 2 Idle+ Bluetooth Idle + WLAN Idle + Battery + USB Cable(Charging from
Adapter) + Earphone + Adapter + SIM Card Mode 8 : LTE Band 5 Idle+ Bluetooth Idle + WLAN Idle + Camera + Battery + USB
Cable(Charging from Adapter) + Earphone + Adapter + SIM Card Mode 9 : LTE Band 7 Idle + Bluetooth Idle + WLAN Idle + MP4 + Battery + USB
Cable(Charging from Adapter) + Earphone + Adapter + SIM Card Mode 10 : LTE Band 12 Idle + Bluetooth Idle + WLAN Idle + PC(data transfer) + Battery +
SIM Card + PC Adapter + Earphone Mode 11 : LTE Band 17 Idle + Bluetooth Idle + WLAN Idle + Battery + USB Cable(Charging from
Adapter) + Earphone + Adapter Mode 12 : LTE Band 66 Idle + Bluetooth Idle + WLAN Idle + Battery + USB Cable(Charging from
Adapter) + Earphone + Adapter Remark: The above test mode in boldface (Mode 8) was the worst case of conducted emission test, only the test data of these modes were reported. The above test mode in boldface (Mode 10) was the worst case of radiated emission test, only the test data of these modes were reported.

During the measurement, the environmental conditions were within the listed ranges:

Temperature (°C): Relative Humidity (%): Atmospheric Pressure (kPa):

15 - 35 30 - 60 86 - 106

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page6of 20

REPORT No.SZ21080255E01

3. 47 CFR Part 15B Requirements

3.1. Conducted Emission

3.1.1. Requirement

According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN).

Frequency range

Conducted Limit (dBµV)

(MHz)

Quasi-peak

Average

0.15 - 0.50

66 to 56

56 to 46

0.50 - 5

56

46

5 - 30

60

50

NOTE:

a) The limit subjects to the Class B digital device.

b) The lower limit shall apply at the band edges.

c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 -

0.50MHz.

3.1.2. Test Setup

Please refer to Annex A for the photographs of the Test Configuration.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page7of 20

REPORT No.SZ21080255E01
The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor, and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power mains through a LISN which provides 50/50µH of coupling impedance for the measuring instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole test system are calibrated to correct the reading.
The power strip or extension cord has been investigated to make sure that the LISN integrity inma intained with respect to the impedance characteristics as prescribed in ANSI C63.4-2014 at Clause 4.3.
3.1.3. Test Result
RBW=9 kHz, VBW=30 kHz. The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average (AV) detectors; the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. All test modes are considered, refer to recorded points and plots below.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page8of 20

A. Test Plot and Suspicious Points:

REPORT No.SZ21080255E01

(Plot A:L Phase)

Fre. NO.
(MHz) 1 0.4944 2 0.6183 3 0.9014 4 1.3937 5 2.3175 6 2.6941

Emission Level (dBµV)

Quai-peak Average

49.26

40.86

44.95

35.75

45.16

36.57

44.32

32.74

42.20

32.09

41.87

31.32

Limit (dBµV)

Quai-peak Average

56.09

46.09

56.00

46.00

56.00

46.00

56.00

46.00

56.00

46.00

56.00

46.00

Power-line Verdict
PASS PASS PASS Line PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page9of 20

REPORT No.SZ21080255E01

(Plot B: N Phase)

Fre. NO. (MHz)
1 0.4570 2 0.5102 3 0.6883 4 1.0231 5 1.8194 6 3.8039

Emission Level (dBµV)

Quai-peak Average

48.64

37.41

51.89

38.22

44.41

33.66

45.46

32.67

43.30

31.26

42.52

30.36

Limit (dBµV)

Quai-peak Average

56.75

46.75

56.00

46.00

56.00

46.00

56.00

46.00

56.00

46.00

56.00

46.00

Power-line Verdict

Neutral

PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page10of 20

REPORT No.SZ21080255E01

3.2. Radiated Emission

3.2.1. Requirement

According to FCC section 15.109 (a), the field strength of radiated emissions from unintentional radiators at a distance of 3 meters shall not exceed the following values:

Frequency range (MHz) 30.0 - 88.0 88.0 - 216.0 216.0 - 960.0 Above 960.0

Field Strength Limitation at 3m Measurement Dist

(µV/m)

(dBµV/m)

100

20log 100

150

20log 150

200

20log 200

500

20log 500

As shown in FCC section 15.35(b), for frequencies above 1000MHz, the field strength limits are based on average detector. When average radiated emission measurements are specified in this part, including emission measurements below 1000MHz, there also is a limit on the radio frequency emissions, as measured using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit for the frequency being investigated unless a different peak emission limit is otherwise specified in the rules.

Note:

1) The tighter limit shall apply at the boundary between two frequency range. 2) Limitation expressed indBµV/m is calculated by 20log Emission Level(µV/m).

3.2.2. Frequency range of measurement

According to 15.33(b)(1), the frequency range of radiated measurement for the EUT is listed in the following table:

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page11of 20

3.2.3. Test Setup 1) For radiated emissions from 30MHz to1GHz

REPORT No.SZ21080255E01

2) For radiated emissions above 1GHz

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page12of 20

REPORT No.SZ21080255E01
The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating Turn Table, and keeps 3m away from the Test Antenna, which is mounted on a variable-height antenna master tower.
For the test Antenna:
In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. The emission levels at both horizontal and vertical polarizations should be tested.
For measurements below 1GHz the resolution bandwidth is set to 120 kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak.
For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video bandwidth is set to 3MHz for peak measurements and as applicable for average measurements.
3.2.4. Test Result
The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels more than the limits, and that have narrow margins from the limits will be re-measured with AV and QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered to perform the tests. All test modes are considered, refer to recorded points and plots below.
The amplitude of emissions (6GHz-13.5GHz)which are attenuated more than 20 dB below the permissible value need not be reported.
Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis test condition was recorded in this test report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page13of 20

REPORT No.SZ21080255E01

(Plot A: ANT-Vertical,30MHz - 1GHz)

Fre.

Pk

QP

AV Limit-PK Limit-QP Limit-AV

No.

ANT Verdict

MHz

dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m

1 49.4019 27.94

N.A

N.A

N.A

40.00

N.A

V PASS

2 168.6269 35.83

N.A

N.A

N.A

43.50

N.A

V PASS

3 332.4762 38.12

N.A

N.A

N.A

46.00

N.A

V PASS

4 480.0280 44.65 43.43

N.A

N.A

46.00

N.A

V PASS

5 717.4107 35.78

N.A

N.A

N.A

46.00

N.A

V PASS

6 959.9350 33.92

N.A

N.A

N.A

46.00

N.A

V PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page14of 20

REPORT No.SZ21080255E01

(Plot B: ANT-Vertical,1GHz - 6GHz)

Fre.

Pk

QP

AV Limit-PK Limit-QP Limit-AV

No.

ANT Verdict

MHz

dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m

1 1329.0658 43.16

N.A

N.A

74.00

N.A

54.00

V PASS

2 1995.1990 50.65

N.A

N.A

74.00

N.A

54.00

V PASS

3 2396.2793 50.77

N.A

N.A

74.00

N.A

54.00

V PASS

4 2660.3321 49.73

N.A

N.A

74.00

N.A

54.00

V PASS

5 3586.5173 45.25

N.A

N.A

74.00

N.A

54.00

V PASS

6 4793.7588 47.80

N.A

N.A

74.00

N.A

54.00

V PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page15of 20

REPORT No.SZ21080255E01

(Plot C:ANT- Horizontal, 30MHz - 1GHz)

Fre.

Pk

QP

AV Limit-PK Limit-QP Limit-AV

No.

ANT Verdict

MHz

dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m

1 30.7761 38.78 30.97

N.A

N.A

40.00

N.A

H PASS

2 47.6558 35.03

N.A

N.A

N.A

40.00

N.A

H PASS

3 186.8647 39.08

N.A

N.A

N.A

43.50

N.A

H PASS

4 238.9589 40.04

N.A

N.A

N.A

46.00

N.A

H PASS

5 333.2523 36.89

N.A

N.A

N.A

46.00

N.A

H PASS

6 480.0280 45.56 45.50

N.A

N.A

46.00

N.A

H PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page16of 20

REPORT No.SZ21080255E01

(Plot D:ANT- Horizontal, 1GHz - 6GHz)

Fre.

Pk

QP

AV Limit-PK Limit-QP Limit-AV

No.

ANT Verdict

MHz

dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m

1 1332.0664 45.47

N.A

N.A

74.00

N.A

54.00

H PASS

2 1440.0880 42.44

N.A

N.A

74.00

N.A

54.00

H PASS

3 1684.1368 41.30

N.A

N.A

74.00

N.A

54.00

H PASS

4 1992.1984 46.19

N.A

N.A

74.00

N.A

54.00

H PASS

5 2396.2793 48.90

N.A

N.A

74.00

N.A

54.00

H PASS

6 4374.6749 41.87

N.A

N.A

74.00

N.A

54.00

H PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page17of 20

Annex A Test Uncertainty

REPORT No.SZ21080255E01

The uncertainty is calculated using the methods suggested in the "Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO.

Uncertainty of Conducted Emission Measurement

Measuring Uncertainty for 9kHz-150kHz a Level of Confidence of 150kHz-30MHz 95%(U=2Uc(y))

±3.3dB ±2.8dB

Uncertainty of Radiated Emission Measurement

Measuring Uncertainty for 30MHz-200MHz

a Level of Confidence of 200MHz-1000MHz

95%(U=2Uc(y))

1GHz-6GHz

6GHz-18GHz

±5.06dB ±5.04dB ±5.18dB ±5.48dB

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page18of 20

REPORT No.SZ21080255E01
Annex B Testing Laboratory Information

1. Identification of the Responsible Testing Laboratory

Laboratory Name: Laboratory Address:
Telephone: Facsimile:

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525

2. Identification of the Responsible Testing Location

Name: Address: 3. Accreditation Certificate

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Accredited Testing Laboratory:
4. Test Software Utilized Model
JS32-RE TS+ -[ JS32-CE]

The FCC designation number is CN1192. Test firm registration number is 226174. (Shenzhen Morlab Communications Technology Co., Ltd.)

Version Number Version 2.0.2.0 Version2.5.0.0

Producer Tonscend Tonscend

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page19of 20

REPORT No.SZ21080255E01

5. Test Equipments Utilized

Description

Model

Bi-Log Antenna VULB 9163

Receiver

N9038A

Horn Antenna BBHA 9120D

6db Attenuator Preamplifier
Preamplifier Receiver LISN
10dB Pulse Limiter

BW-N6W5+ S020180L320
3 S10M100L380
2 ESPI NSLK 8127
VTSD 9561-F

Serial No. 9163-519 MY56400093 9120D-963 E191001 61171/61172
46732 101052 8127449 VTSD 9561 F-B #206

Manufacturer SCHWARZBE
CK KEYSIGHT SCHWARZBE
CK Mini-circuits

Cal. Date 2019/5/24 2021/3/9 2019/5/24 2021/10/18

LUCIX CORP. 2021/7/15

LUCIX CORP. 2021/7/15

R&S Schwarzbeck SCHWARZBE
CK

2021/7/16 2021/3/9
2021/7/21

Due. Date 2022/5/23 2022/3/8 2022/5/23 2022/10/17 2022/7/14
2022/7/14 2022/7/15 2022/3/8 2022/7/20

6. Ancillary Equipment Utilized

Description PC
PC Adapter Earphone

Manufacturer DELL DELL N/A

Model VOSTRO 5370
LA45NM140 N/A

Serial No. 2017AP6215
051F-A09 N/A

END OF REPORT

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen ,GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page20of 20


Microsoft Word 2019 Microsoft Word 2019