Resistex Argos déco Installation Instructions
Version: V1.1 - 05.24
Safety Notes
- Never work when voltage is present on the luminaire.
- The installation must be performed by a professional installer in compliance with the standards and regulations relating to electrical installations.
- Risk of electrostatic discharges. (ESD Norm). Handle with precautions.
- Please observe the notes and steps described in the mounting instructions.
Maintenance Instructions
- Do not use chemicals or abrasives products to clean the fixture.
- Keep these instructions for dismantling or future maintenance.
- Additional information about RESISTEX luminaires is available on the website www.resistex-sa.com.
- RESISTEX cannot be responsible for any misuse of the product.
Installation Guide
The installation process involves two main kits: Ceiling Kit (Plafonnier) and Suspension Kit.
Kit Plafonnier (Ceiling Kit)
- Preparation: Mark the desired mounting location on the ceiling. Use a spirit level to ensure accuracy. Drill holes using a 6mm drill bit (6) and insert appropriate wall plugs (quantity 2, X2).
- Bracket Mounting: Securely attach the mounting bracket to the ceiling using screws (quantity 2, X2).
- Electrical Connection: Connect the luminaire's wires to the mains supply. Identify and connect Neutral (N), Earth (E), and Live (L) wires correctly.
- Luminaire Attachment: Mount the luminaire onto the installed bracket.
- Securing: Ensure the luminaire is firmly attached and all electrical connections are safe.
Kit Suspension (Suspension Kit)
- Preparation: Mark the desired mounting location on the ceiling. Use a spirit level to ensure accuracy. Drill holes using a 6mm drill bit (6) and insert appropriate wall plugs (quantity 2, X2).
- Bracket Mounting: Securely attach the mounting bracket to the ceiling using screws (quantity 2, X2).
- Cable Attachment: Attach the suspension cables to the luminaire body (quantity 2, X2).
- Electrical Connection: Connect the luminaire's wires to the mains supply. Identify and connect Neutral (N), Earth (E), and Live (L) wires correctly.
- Cable Suspension: Connect the suspension cables to the ceiling mounting points (quantity 2, X2).
- Luminaire Attachment: Mount the luminaire onto the ceiling bracket.
- Securing: Ensure the luminaire is firmly attached and all electrical connections are safe.
Certifications
The product complies with the following standards:
- ROHS
- CLASS I
- IP65 (Ingress Protection rating)
- IK08 (Impact Protection rating)
- IRC (High Color Rendering Index)
- CE (Conformité Européenne)