MANUAL ON LOAD If No Sensor is Used, Tie the SPODM White Wire to Red Wire Note: up to 2 with neutral-less Note: up to 9 with neutral PNK * 0-10V Dimming Common from fixture may be pink or as otherwise indicated per section 410.69 of the 2020 NEC LOAD 3 PNK LOAD 2 PNK LOAD 1 PNK LOAD 2 PNK LOAD 1 * 0-10V Dimming Common from fixture may be pink
AUTO. ON. LOAD. MANUAL. ON. LOAD. If No Sensor is Used, Tie the SPODM White Wire to Red Wire. Note: up to 2 with neutral-less. Note: up to 9 with neutral.
Quick Recommendation Guide Typical Applications Private Offices Up to 15'x15' Without Obstructions With Obstructions Up to 20'x20' 0-10V Dimming Conference Rooms Up to 15'x15' Up to 20'x20' WSXA** / WSXA D** WSXA PDT** / WSXA PDT D** CM PDT 9* WSXA PDT D** or SPODMRA D** WSXA PDT** / WSXA PDT D** CM PDT 9* Up to 30'x30' Classrooms Up to 30'x30' Greater than 30'x30' Open Office Areas WV PDT 16* WV PDT 16* Mult. WV PDT 16* or CM PDT* 8'-10' Mounting Height Multiple CM PDT 9* Restrooms Private WSXA ** / WSXA D** Private with Fan Up to 4 Stalls 4 to 7 Stalls WSXA 2P: FAN** WSXA PDT** / WSXA PDT D** CM PDT 9* More than 7 Stalls Multiple CM PDT 9* Corridors 9' Mounting Height CM 10* 12' Mounting Height Gymnasiums 25' Mounting Height Warehouses 360°, 15' - 45' Mounting Height CM 10* LSXR 6 LSXR 6 Aisle Control LSXR 50 (Typical Energy Savings: 30% - 50%) Sensor must have visibility to desktop activity Small rooms without direct line of sight (also required if occupant has back to sensor) Place within visual sight of main entry door LED dimming control with or without motion sensor (Typical Energy Savings: 30% - 50%) Sensor will detect both motion and sound Place within visual sight of main entry door Place sensor in corner along entrance wall (Typical Energy Savings: 40% - 60%) Place sensor in corner along entrance wall Place sensors in opposite corners (Typical Energy Savings: 20% -40%) Place sensors on 25' - 30' centers and cover all entrances (Typical Energy Savings: 50% - 80%) For rooms without obstructions No obstructions, relay 1 controls lights, relay 2 is for fan For rooms with obstructions Place within visual sight of the main entry door Contact your Acuity Sales Representative for assistance (Typical Energy Savings: 20% - 60%) Place sensors 50' on center Place sensors 60' on center (Typical Energy Savings: 20% - 50%) Place sensors on 40' centers and cover all entrances (Typical Energy Savings: 20% - 50%) 1 sensor per fixture Coverage spans multiple fixtures * Requires power pack(s). Results typical; actual savings may differ. **WSD series may be substituted in place of the WSX; see datasheet for product details. Signifies switches that are JOT enabled for single room lighting controls. Wall Switch Sensor WSXA Wall Switch with Dimming WSXA D Switch Interface SPODMRA D Ceiling Mount Sensor CM Wide View Sensor WV Fixture Mount Sensor LSXR www.acuitybrands.com/sensorswitch Wiring Diagrams LINE VOLTAGE SENSOR (i.e., CMR 9) LOW VOLTAGE Single Sensor (i.e., CM 9) R - RELAY OPTION PP20 BLK - 120 V ORN - 277 V D, ADC - DIMMING OPTIONS PNK D, P, ADC - PHOTOCELL / DIMMING OPTIONS PP20 BLK - 120 V ORN - 277 V Multiple Sensors (i.e., wv 16 & CM 9) WIRING TO GROUND (NO NEUTRAL) Wall Switch Sensor Single Relay Dual Relay WIRING TO NEUTRAL Wall Switch Sensor Single Relay Dual Relay Wire Color Key for Wiring to Ground or Wiring to Neutral 120/277 VAC Wiring ¡ Black* ¡ Black* Line 1 Input Load 1 Output Black Wires can be reversed ¡ Blue* ¡ Blue* Line 2 Input Load 2 Output Blue Wires can be reversed Notes: 1. Unit will draw power from either line connection. 2. When switching 277 VAC or 347 VAC on both relays, the line inputs must be of the same phase. BI-LEVEL (AUTO-ON/MANUAL ON) SOLUTION WITH CEILING SENSOR: 2-GANG Class 1 Connections PP20 AUTO ON LOAD SP20 MANUAL ON LOAD If No Sensor is Used, Tie the SPODM White Wire to Red Wire LINE VOLTAGE - SINGLE RELAY (I.E., LSXR XX) Notes 1. Black wires can be reversed 2. Wire is red for HVOLT version (required for 347 VAC) 3. Disconnect and cap black output wire going to driver/ballast if PNK switching fixture is not required. FIXTURE BALLAST or LED DRIVER SINGLE RELAY, MULTI-WAY CONFIGURATION, 120-277 VAC LOAD 3 PNK LOAD 2 PNK Note: up to 9 with neutral LOAD 1 PNK * 0-10V Dimming Common from fixture may be pink or as otherwise indicated per section 410.69 of the 2020 NEC SINGLE RELAY, MULTI-WAY CONFIGURATION, 120-277 VAC LOAD 2 PNK LOAD 1 PNK * 0-10V Dimming Common from fixture may be pink or as otherwise indicated per section 410.69 of the 2020 NEC Note: up to 2 with neutral-less LINE VOLTAGE - DUAL RELAY (I.E., LSXR XX 2P) Notes 1. Black wires can be reversed. 2. Blue wires can be reversed. 3. Wire is red 347 VAC version. 4. Red wires can be reversed. Load 1 FIXTURE BALLAST or LED DRIVER Load 2 FIXTURE BALLAST or LED DRIVER One Lithonia Way | Conyers, Georgia 30012 | 800.535.2465 | www.acuitybrands.com ©2020 Acuity Brands Lighting, Inc. All rights reserved. | SSI_5989_1120Adobe PDF Library 15.0 Adobe InDesign 16.0 (Macintosh)