Product Overview
A modern, wall-mounted electric vehicle charger is presented, featuring a sleek white casing, a dark grey charging cable, and a connector. The TCL logo is prominently displayed on the charger's front panel.
Key Features
- ✔️ Easy Installation: Designed with bottom wiring for straightforward setup and does not require a separate mounting bracket.
- ? User Friendly: Supports plug&charge functionality, allows for reserve charging time scheduling, and enables local dynamic load management.
- ?️ Higher Safety Standard: Equipped with both RCD DC and AC protection, and rated IP 65 for dust and water resistance, and IK 10 for impact resistance.
- ☁️ All-in-One Function Under TCL Home: Seamlessly integrates with PV modules, Energy Storage Systems (ESS), and heat pumps, all controllable via the TCL home ecosystem.
Product Specifications
TCL-RSA-7KW
Category | Specification |
---|---|
General Information | |
Charging Mode | Mode 3 (IEC) |
Input/Output Power&Current Rating | 7kW / 32A max. |
Input/Output Voltage Rating | 184-264Vac, single phase, 45~65Hz, L+N+PE |
Grid Type | TN-S, TN-C-S, TT, IT(L1+L2 230Vac Single phase) |
Charging Interface | IEC 62196-2 Type 2 tethered plug (Case C) |
Metering | Onboard metering chip |
Power Consumption | 4W |
Residual Current Protection | Type A 30mA + DC 6mA |
Protection | Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature, Grounding fault, |
User Interface | |
Status Indication | LED indicator |
Bluetooth | 5.0 |
Button & Switch | No emergency button, with rotary switch inside (used for setting output current limitation) |
User Authentication | RFID card, APP |
RFID Reader | ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693 |
Communication | |
Network Interface | Bluetooth, RS485 |
Protocol (EVSE&Backend) | OCPP 1.6J |
Protocol (EVSE&EV) | Control pilot |
Environmental | |
Operating Temperature | -30°C to 50℃ |
Storage Temperature | -40°C to 85℃ |
Humidity | 5% to 95% no condensation |
Altitude | <3000m above sea level |
Mechanical | |
IP Rating | IP65 |
IK Rating | IK10 |
Cooling | Natural cooling |
Charging Cable Length | 5m |
Dimensions (WxHxD) | 280*280*148 mm (without Pole), 280*1210*201mm (with Pole) |
Weight | Approx. 4kg |
Installation | Wall mounting, Pole mounting (Pole is optional) |
Certification and Standards | |
Standards and Compliance | IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU, IEC 62955 (RCD), 2014/32/EU (Metering), EN 62052-11: 2021, EN-IEC 62052-11/A11, EN 50470-3: 2022 |
Certification | CE-RED, CB |
TCL-RSAS-7KW
Category | Specification |
---|---|
General Information | |
Charging Mode | Mode 3 (IEC) |
Input/Output Power&Current Rating | 7kW / 32A max. |
Input/Output Voltage Rating | 184-264Vac, single phase, 45~65Hz, L+N+PE |
Grid Type | TN-S, TN-C-S, TT, IT(L1+L2 230Vac Single phase) |
Charging Interface | IEC 62196-2 Type 2 tethered plug (Case C) |
Metering | Onboard metering chip |
Power Consumption | 4W |
Residual Current Protection | Type A 30mA + DC 6mA |
Protection | Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature, Grounding fault, |
User Interface | |
Status Indication | LED indicator |
Bluetooth | 5.0 |
Button & Switch | No emergency button, with rotary switch inside (used for setting output current limitation) |
User Authentication | RFID card, APP |
RFID Reader | ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693 |
Communication | |
Network Interface | Wi-Fi, Ethernet, 4G, Bluetooth, RS485 |
Protocol (EVSE&Backend) | OCPP 1.6J |
Protocol (EVSE&EV) | Control pilot |
Environmental | |
Operating Temperature | -30°C to 50℃ |
Storage Temperature | -40°C to 85℃ |
Humidity | 5% to 95% no condensation |
Altitude | <3000m above sea level |
Mechanical | |
IP Rating | IP65 |
IK Rating | IK10 |
Cooling | Natural cooling |
Charging Cable Length | 5m |
Dimensions (WxHxD) | 280*280*148 mm (without Pole), 280*1210*201mm (with Pole) |
Weight | Approx. 4kg |
Installation | Wall mounting, Pole mounting (Pole is optional) |
Certification and Standards | |
Standards and Compliance | IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU, IEC 62955 (RCD), 2014/32/EU (Metering), EN 62052-11: 2021, EN-IEC 62052-11/A11, EN 50470-3: 2022 |
Certification | CE-RED, CB |
TCL-RTA-11KW
Category | Specification |
---|---|
General Information | |
Charging Mode | Mode 3 (IEC) |
Input/Output Power&Current Rating | 11kW (3.5kW for single phase wiring) / 16A max. |
Input/Output Voltage Rating | 184-264Vac, single phase, 45~65Hz, L1+N+PE |
Grid Type | TN-S, TN-C-S, TT, IT(L1+L2 230Vac Single phase, optional) |
Charging Interface | IEC 62196-2 Type 2 tethered plug (Case C) |
Metering | Onboard metering chip |
Power Consumption | 4W |
Residual Current Protection | Type A 30mA + DC 6mA |
Protection | Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature, Grounding fault, |
User Interface | |
Status Indication | LED indicator |
Bluetooth | 5.0 |
Button & Switch | No emergency button, with rotary switch inside (used for setting output current limitation) |
User Authentication | RFID card, APP |
RFID Reader | ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693 |
Communication | |
Network Interface | Bluetooth, RS485 |
Protocol (EVSE&Backend) | OCPP 1.6J |
Protocol (EVSE&EV) | Control pilot |
Environmental | |
Operating Temperature | -30°C to 50℃ |
Storage Temperature | -40°C to 85℃ |
Humidity | 5% to 95% no condensation |
Altitude | <3000m above sea level |
Mechanical | |
IP Rating | IP65 |
IK Rating | IK10 |
Cooling | Natural cooling |
Charging Cable Length | 5m |
Dimensions (WxHxD) | 280*280*148 mm (without Pole), 280*1210*201mm (with Pole) |
Weight | Approx. 4kg |
Installation | Wall mounting, Pole mounting (Pole is optional) |
Certification and Standards | |
Standards and Compliance | IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU, IEC 62955 (RCD), 2014/32/EU (Metering), EN 62052-11: 2021, EN-IEC 62052-11/A11, EN 50470-3: 2022 |
Certification | CE-RED, CB |
TCL-RTAS-11KW
Category | Specification |
---|---|
General Information | |
Charging Mode | Mode 3 (IEC) |
Input/Output Power&Current Rating | 11kW (3.5kW for single phase wiring) / 16A max. |
Input/Output Voltage Rating | 184-264Vac, single phase, 45~65Hz, L1+N+PE 400Vac ±15%, three phase, 45~65Hz, L1+L2+L3+N+PE |
Grid Type | TN-S, TN-C-S, TT, IT(L1+L2 230Vac Single phase, optional) |
Charging Interface | IEC 62196-2 Type 2 tethered plug (Case C) |
Metering | Onboard metering chip |
Power Consumption | 4W |
Residual Current Protection | Type A 30mA + DC 6mA |
Protection | Overcurrent, Overvoltage, Undervoltage, Residual current, Short circuit, Over temperature, Grounding fault, Integrated surge protection |
User Interface | |
Status Indication | LED indicator |
Bluetooth | 5.0 |
Button & Switch | No emergency button, with rotary switch inside (used for setting output current limitation) |
User Authentication | RFID card, APP |
RFID Reader | ISO/IEC 14443 A/B, ISO/IEC 18092, IEC/ISO 15693 |
Communication | |
Network Interface | Wi-Fi, Ethernet, 4G, Bluetooth, RS485 |
Protocol (EVSE&Backend) | OCPP 1.6J |
Protocol (EVSE&EV) | Control pilot |
Environmental | |
Operating Temperature | -30°C to 50℃ |
Storage Temperature | -40°C to 85℃ |
Humidity | 5% to 95% no condensation |
Altitude | <3000m above sea level |
Mechanical | |
IP Rating | IP65 |
IK Rating | IK10 |
Cooling | Natural cooling |
Charging Cable Length | 5m |
Dimensions (WxHxD) | 280*280*148 mm (without Pole), 280*1210*201mm (with Pole) |
Weight | Approx. 4kg |
Installation | Wall mounting, Pole mounting (Pole is optional) |
Certification and Standards | |
Standards and Compliance | IEC 61851-1, IEC 61851-21-2, LVD 2014/35/EU, RED 2014/53/EU, IEC 62955 (RCD), 2014/32/EU (Metering), EN 62052-11: 2021, EN-IEC 62052-11/A11, EN 50470-3: 2022 |
Certification | CE-RED, CB |