
User Manual for Palmer models including: 1 CH, River Series, RIVER Series 1-Kanal Line Isolation Box Passiv, 1-Kanal Line Isolation Box Passiv, 1-Kanal Box Passiv, Box Passiv, Passiv, Line Isolation Box Passiv
Palmer iller Line Isolator 1 CH ► günstig kaufen bei Huss Licht & Ton
File Info : application/pdf, 16 Pages, 1.66MB
DocumentDocumentBEDIENUNGSANLEITUNG USER MANUAL MANUAL DE USUARIO MANUEL D'UTILISATEUR MANUAL DE INSTRUCCIONES INSTRUKCJA OBSLUGI 1-Kanal Line Isolation Box passiv river series iller 1 RIVER SERIES DE BEDIENUNGSANLEITUNG EN USER MANUAL IT MANUAL DE USUARIO FR MANUEL D'UTILISATEUR ES MANUAL DE INSTRUCCIONES PL INSTRUKCJA OBSLUGI 2 RIVER SERIES FRANKFURT iller Lass deine Signale fließen, natürlich und kraftvoll wie ein Fluss! Die River Series verkörpert diesen Anspruch bis ins Detail: Mit hochpräzisen Schaltungen, designt von unseren preisgekrönten Ingenieuren, damit dein Sound unverfälscht sein Ziel erreicht: das Herz deiner Zuhörer. Denn genau dafür steht Palmer®. Schon seit 1980 fertigen wir Audio-Tools für den professionellen Einsatz auf der Bühne, beim Rundfunk und im Studio. Musiker und Toningenieure weltweit schätzen unsere in Deutschland entwickelten Lösungen für ihren ungehinderten Signalfluss und reinen Klang kristallklar und lebendig wie Wasser! Was lag also näher als die Modelle der River Series nach deutschen Flüssen zu benennen? Auf der Deutschland Karte siehst du, wo die Iller entlangfließt: 147 Kilometer zwischen Bayern und Baden-Württemberg. Vielen Dank für den Kauf der iller! Wir wünschen dir viel Freude mit diesem Stück deutscher Ingenieurskunst. Be True To Your Sound! Dein Palmer Team 3 DE BEDIENUNGSANLEITUNG iller 1-Kanal Line Isolation Box passiv BESTIMMUNGSGEMÄSSER GEBRAUCH Bei dem Produkt handelt es sich um ein Gerät für die Veranstaltungstechnik, sowie Studio, TV und Broadcast! Das Produkt ist für den professionellen Einsatz im Bereich der Veranstaltungstechnik, sowie Studio, TV und Broadcast entwickelt worden und ist nicht für die Verwendung in Haushalten geeignet! Weiterhin ist dieses Produkt nur für qualifizierte Benutzer mit Fachkenntnissen im Umgang mit Veranstaltungstechnik, sowie Studio, TV und Broadcast vorgesehen! Die Benutzung des Produkts außerhalb der spezifizierten technischen Daten und Betriebsbedingungen gilt als nicht bestimmungsgemäß! Haftung für Schäden und Drittschäden an Personen und Sachen durch nicht bestimmungsgemäßen Gebrauch ist ausgeschlossen! Das Produkt ist nicht geeignet für: Personen (einschließlich Kinder) mit eingeschränkten körperlichen, sensorischen oder geistigen Fähigkeiten oder mangelnder Erfahrung und Kenntnis. Kinder (Kinder müssen angewiesen werden, nicht mit dem Gerät zu spielen). SICHERHEITSHINWEISE 1. Lesen Sie diese Anleitung bitte sorgfältig durch. 2. Bewahren Sie alle Informationen und Anleitungen an einem sicheren Ort auf. 3. Befolgen Sie die Anweisungen. 4. Verwenden Sie das Gerät nur in der dafür vorgesehenen Art und Weise. 5. Öffnen Sie das Gerät nicht und verändern Sie es nicht. ERSTICKUNGSGEFAHR! VON KINDERN FERNHALTEN! DAS PRODUKT ENTHÄLT VERSCHLUCKBARE KLEINTEILE UND VERSCHLUCKBARES VERPACKUNGSMATERIAL! KUNSTSTOFFBEUTEL MÜSSEN AUSSER REICHWEITE VON KINDERN AUFBEWAHRT WERDEN! EINFÜHRUNG Die Line Isolation Box iller ist eingangsseitig mit einer Combo-Buchse ausgestattet, die mit einem XLR- oder 6,3 mm Klinkenstecker belegbar ist. Der Eingang erlaubt den Anschluss von Zuspielgeräten mit symmetrischen oder unsymmetrischen Anschlüssen. Der symmetrische Line-Ausgang ist mit einer männlichen XLR-Buchse ausgestattet. Zwischen Ein- und Ausgang besteht eine galvanische Trennung durch einen hochwertigen Übertrager. Mit Hilfe des Ground Lift-Schalters zum Trennen der Masseverbindung von Ein- und Ausgang werden Brummschleifen und andere Störsignale wirkungsvoll beseitigt. Audiosignale können mit Hilfe der Line Isolation Box außerdem über weite Kabelwege brummfrei übertragen werden. 4 DE BEDIENUNGSANLEITUNG iller 1-Kanal Line Isolation Box passiv 1 3 2 ANSCHLÜSSE 1. INPUT Line-Eingang mit Combo-Buchse (XLR / 6,3 mm Klinke), der sowohl für unsymmetrische als auch für symmetrische Verkabelung geeignet ist. Verwenden Sie ein abgeschirmtes Audiokabel, um beispielsweise ein Keyboard an der Line Isolation Box anzuschließen. 2. OUTPUT Symmetrischer Line-Ausgang mit 3-Pol XLR-Buchse. Verwenden Sie ein abgeschirmtes Audiokabel, um die Line Isolation Box an einen symmetrischen Eingang eines Mischpults oder Audio-Interfaces anzuschließen. 3. LIFT / GND Schalter zum Trennen der Masseverbindung von Ein- und Ausgang (Ground Lift). In der nicht gedrückten Position ist die Masseverbindung getrennt, die Verbindung besteht bei gedrückter Position. Die Fähigkeit, mit Hilfe des Ground Lift-Schalters eine Brummschleife zu verhindern, hängt von der Erdung der angeschlossenen Geräte ab. Es besteht daher die Möglichkeit, dass sowohl die eine, als auch die andere Schalterposition in der Lage ist, ein Brummen wirkungsvoll zu reduzieren bzw. zu beseitigen. ACHTUNG: Das Anschließen von Signalkabeln kann zu erheblichen Störgeräuschen führen. Achten Sie darauf, dass Eingangskanäle von Mischpulten und Audio-Interfaces usw. bei Steckvorgängen stummgeschaltet sind. Andernfalls können Pegel von Störgeräuschen zu Schäden führen. HINWEIS: Starke Magnetfelder können Brummen verursachen. Positionieren Sie die Line Isolation Box daher nicht in der Nähe von starken Magnetfeldern (z.B. Netztrafo). 5 DE BEDIENUNGSANLEITUNG VERKABELUNGSBEISPIEL balanced or unbalanced signal balanced or unbalanced signal same level as input no ground loop hum 6 DE BEDIENUNGSANLEITUNG TECHNISCHE DATEN ALLGEMEIN Artikelnummer Produktart Anzahl Kanäle Typ Übertrager isoliert Anzahl Eingänge Eingangstyp Eingangsanschlüsse Anzahl Ausgänge Ausgangstyp Ausgangsanschlüsse Ground/Lift Schalter Gehäuse Abmessungen (H/B/T) Gewicht Umgebungstemperatur im Betrieb Relative Luftfeuchtigkeit Enthaltenes Zubehör PILLER Line Isolator 1 passiv Ja 1 symmetrisch/unsymmetrisch 6,3 mm Klinke, XLR 1 symmetrisch/unsymmetrisch XLR Ja Aluminium Strangguss 110 x 50 x 50 mm 0,3 kg -20°C...70°C <80 %, nicht kondensierend Gummifüße, Beschriftungsschild AUDIO Max. Eingangspegel (< 1% THD, 20 Hz) +10 dBu Max. Eingangspegel (< 1% THD, 1 kHz) +32 dBu Frequenzgang (±0,2dB, relative 1kHz) 20 Hz - 20 kHz Eingangsimpedanz (1 kHz) 17 k Ausgangsimpedanz (1 kHz) 500 THD (30 Hz, +4 dBu, unity, ungewichtet) < 0,09 % THD (1 kHz, +4 dBu, unity, ungewichtet) < 0,002 % IMD (SMPTE) (60 Hz / 7 kHz, 4:1, +4 dBu) < 0,002 % Übertrager-Verhältnis 1:1 Alle Messungen wurden mit einem Generator mit 600 Ausgangsimpedanz und 20 k symmetrischer Last durchgeführt. 7 DE BEDIENUNGSANLEITUNG 8 DE BEDIENUNGSANLEITUNG ENTSORGUNG VERPACKUNG: 1. Verpackungen können über die üblichen Entsorgungswege dem Wertstoffkreislauf zugeführt werden. 2. Bitte trennen Sie die Verpackung entsprechend der Entsorgungsgesetze und Wertstoffverordnungen in Ihrem Land. GERÄT: 1. Dieses Gerät unterliegt der europäischen Richtlinie für Elektro- und Elektronik-Altgeräte in der jeweils geltenden aktuellen Fassung. WEEE-Richtlinie Waste Electrical and Electronical Equipment. Altgeräte gehören nicht in den Hausmüll. Das Altgerät muss über einen zugelassenen Entsorgungs betrieb oder eine kommunale Entsorgungsein richtung entsorgt werden. Bitte beachten Sie geltende Vorschriften in Ihrem Land! 2. Beachten Sie alle in Ihrem Land geltenden Entsorgungsgesetze. 3. Als Privatkunde erhalten Sie Informationen zu umweltfreundlichen Entsorgungsmöglichkeiten über den Händler, bei dem das Produkt erworben wurde, oder über die entsprechen den regionalen Behörden. BATTERIEN UND AKKUS: 1. Batterien und Akkus gehören nicht in den Hausmüll. Batterien und Akkus müssen über einen zugelassenen Entsorgungsbe trieb oder eine kommunale Entsorgungs einrichtung entsorgt werden. HERSTELLERERKLÄRUNGEN Herstellergarantie & Haftungsbeschränkung Adam Hall GmbH Adam-Hall-Str. 1 D-61267 Neu Anspach E-Mail. Info@adamhall.com / +49 (0)6081 / 9419-0. Unsere aktuellen Garantiebedingungen und Haftungsbeschränkung finden Sie unter: https://cdn-shop.adamhall.com/media/pdf/Manufacturers-Declarations-PALMER_DE_EN_ES_FR.pdf Im Servicefall wenden Sie sich an Ihren Vertriebspartner. CE-KONFORMITÄT Hiermit erklärt die Adam Hall GmbH, dass dieses Produkt folgender Richtlinie entspricht (soweit zutreffend): Niederspannungsrichtlinie (2014/35/EU) EMV-Richtlinie (2014/30/EU) RoHS (2011/65/EU) RED (2014/53/EU) CE-KONFORMITÄTSERKLÄRUNG Konformitätserklärungen für Produkte, die der LVD, EMC, RoHS-Richtlinie unterliegen, können unter info@adamhall.com angefragt werden.Konformitätserklärungen für Produkte, die der RED-Richtlinie unterliegen, können unter www.adamhall.com/compliance/ heruntergeladen werden. FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 2. Beachten Sie alle in Ihrem Land geltenden Entsorgungsgesetze und Vorschriften. 3. Als Privatkunde erhalten Sie Informationen zu umweltfreundlichen Entsorgungsmöglichkeiten über den Händler, bei dem das Produkt erworben wurde, oder über die entsprechenden regionalen Behörden. (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation 4. Geräte mit Batterien oder Akkus, die nicht durch den Benutzer entfernt werden können, müssen an einer Sammelstelle für Elektrogeräte abgegeben werden. 9 DE RIVER SERIES FRANKFURT iller Let your signals flow, naturally and powerfully like a river! The River Series embodies this claim down to the last detail: featuring high-precision circuits, designed by our award-winning engineers to ensure your sound reaches its destination the hearts of your listeners. That's exactly what Palmer® stands for. We have been manufacturing audio tools for professional use on stage, in broadcasting and in the studio since 1980. Musicians and sound engineers around the world value our solutions developed in Germany for their unhindered signal flow and pure sound as crystal clear and vibrant as water! So what was more logical than naming the River Series models after German rivers? On the map of Germany you can see where the Iller flows: 147 kilometres between Bavaria and Baden-Württemberg. Thank you for purchasing the iller! We hope you enjoy this piece of German engineering. Be true to your sound! Yours, the Palmer Team 10 EN USER MANUAL iller 1-Channel Line Isolation Box passive INTENDED USE This product is a device for event technology, as well as studio, TV and broadcast! This product has been developed for professional use in the fields of event technology, studio, TV and broadcast. It is not suitable for household use! Furthermore, this product is only intended for qualified users with specialist knowledge of event technology, as well as studio, TV and broadcast! Use of the product outside the specified technical data and operating conditions is considered inappropriate! Liability for damage and third-party damage to persons and property due to inappropriate use is excluded! The product is not suitable for: Persons (including children) with limited physical, sensory or mental abilities or lack of experience and knowledge. Children (children must be instructed not to play with the device). SAFETY INSTRUCTIONS 1. Please read these instructions carefully. 2. Keep all information and instructions in a safe place. 3. Follow the instructions. 4. Use the device in the prescribed manner only. 5. Do not open the device and do not perform any modifications. CHOKING HAZARD! KEEP OUT OF THE REACH OF CHILDREN! THE PRODUCT CONTAINS SMALL PARTS AND PACKAGING MATERIAL THAT CAN BE SWALLOWED! PLASTIC BAGS MUST BE KEPT OUT OF THE REACH OF CHILDREN! INTRODUCTION The iller Line Isolation Box is equipped with a combo socket on the input side, which can be assigned with an XLR or 6.3 mm jack plug. The input allows the connection of playback devices with balanced or unbalanced connections. The balanced line output is equipped with a male XLR socket. There is galvanic isolation between input and output by means of a high-quality transformer. With the help of the ground lift switch to disconnect the ground connection of input and output, hum loops and other interfering signals are effectively eliminated. Audio signals can also be transmitted hum-free over long cable runs with the help of the iller. 11 EN USER MANUAL iller 1-Channel Line Isolation Box passive 1 3 2 CONNECTIONS 1. INPUT Line input with combo jack (XLR / 6.3 mm jack) suitable for both unbalanced and balanced cabling. Use a shielded audio cable to connect, for example, a keyboard to the Line Isolation Box. 2. OUTPUT Balanced line-out via 3-pin XLR jack. Use a shielded audio cable to connect the Line Isolation Box to a balanced input of a mixing console or audio interface. 3. LIFT / GND Switch for disconnecting the ground connection from the input and output (ground lift). In the non-pressed position, the ground connection is disconnected; the connection is established when the switch is pressed. The ability to prevent a humming loop using the ground lift switch depends on the grounding of the connected device. It is therefore possible that the switch is able to effectively reduce or eliminate humming when it is either up or down, depending on circumstances. CAUTION: Connecting signal cables can cause considerable noise. Please make sure that the input channels of mixing console and audio interfaces, etc. are muted when plugged in. Otherwise, noise levels may cause damage. NOTE: Strong magnetic fields can cause humming. Therefore, do not position the Line Isolation Box near strong magnetic fields (e.g. mains transformer). 12 EN BEDIENUNGSANLEITUNG WIRING EXAMPLE balanced or unbalanced signal balanced or unbalanced signal same level as input no ground loop hum 13 EN USER MANUAL TECHNICAL DATA GENERAL Product number Product type No. of channels Type Transformer isolated No. of inputs Input type Input connections No. of outputs Output type Output connections Ground/lift switch Housing Dimensions (H/W/D) Weight Ambient temperature for operation Relative air humidity Included accessories PILLER Line Isolator 1 passive yes 1 symmetrical/asymmetrical 6.3 mm Jack, XLR 1 symmetrical/asymmetrical XLR yes Aluminium continuous casting 110 x 50 x 50 mm 0.3 kg -20°C...70°C <80 %, non-condensing Rubber feet, inscription label AUDIO Max. Input level (< 1% THD, 20 Hz) +10 dBu Max. Input level (< 1% THD, 1 kHz) +32 dBu Frequency response (±2dB, relative 1kHz) 20 Hz - 20 kHz Input impedance (1 kHz, setting: 0 dB PAD) 17 k Output impedance (1 kHz, setting: 0 dB PAD) 500 THD (30 Hz, +4 dBu, unity, unweighted) < 0.09 % THD (1 kHz, +4 dBu, unity, unweighted) < 0.002 % IMD (SMPTE) (60 Hz / 7 kHz, 4:1, +4 dBu) < 0.002 % Transformer ratio 1:1 All measurements were performed with a generator with 600 output impedance and 20 k balanced load. 14 EN USER MANUAL 15 EN USER MANUAL DISPOSAL PACKAGING: 1. Packaging can be fed into the reusable material cycle using the usual disposal methods. 2. Please separate the packaging in accordance with disposal laws and recycling regulations in your country. DEVICE: 1. This device is subject to the European Waste Electrical and Electronic Equipment Directive in the currently valid version. WEEE Waste Electrical and Electronic Equipment Directive. Old appliances do not belong in household waste. The old device must be disposed of via an approved disposal company or a municipal disposal facility. Please observe the applicable regulations in your country! 2. Observe all disposal laws applicable in your country. MANUFACTURER'S DECLARATIONS Manufacturer's warranty & limitation of liability Adam Hall GmbH Adam-Hall-Str. 1 61627, Neu-Anspach, Germany Email: Info@adamhall.com / +49 (0)6081 / 9419-0. Our current warranty conditions and limitation of liability can be found at: https://cdn-shop.adamhall.com/media/pdf/Manufacturers-Declarations-PALMER_DE_EN_ES_FR.pdf Contact your distribution partner for service. CE CONFORMITY Adam Hall GmbH hereby confirm that this product meets the following guidelines (where applicable): Low-Voltage Directive (2014/35/EU) EMC Directive (2014/30/EU) RoHS (2011/65/EU) RED (2014/53/EU) 3. As a private customer, you can obtain information on environmentally friendly disposal options from the seller of the product or the appropriate regional authorities. BATTERIES: 1. Batteries should not be disposed of in house- hold waste. Batteries and rechargeable batteries must be disposed of via an approved disposal company or a municipal disposal facility. EC DECLARATION OF CONFORMITY Declarations of conformity for products that are subject to the LVD, EMC, RoHS Directives, can be requested at info@adamhall.com. Declarations of conformity for products that are subject to the RED Directive can be downloaded at www.adamhall.com/compliance/ . FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 2. Observe all disposal laws applicable in your country. 3. As a private customer, you can obtain information on environmentally friendly disposal options from the seller of the product or through the relevant regional authorities. 4. Devices with batteries that cannot be removed by the user must be taken to a collection point for electrical appliances. (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation UKCA- CONFORMITY Hereby, Adam Hall Ltd. declares that this product meets the following guidelines (where applicable) Electrical Equipment (Safety) Regulations 2016 Electromagnetic Compatibility Regulations 2016 (SI 2016/1091) The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulation 2012 (SI 2012/3032) Radio Equipment Regulations 201 7(SI 2016/2015) UKCA- DECLARATION OF CONFORMITY Products that are subject to Electrical Equipment(Safety) Regulation 2016, EMC Regulation 2016 or RoHS Regulation can be requested at info@adamhall.com. Products that are subject to the Radio Equipments Regulations 2017 (SI2017/1206) can be downloaded from www.adamhall.com/compliance/ EN SUBJECT TO MISPRINTS AND ERRORS, AS WELL AS TECHNICAL OR OTHER MODIFICATIONS! 16