4 TSFLUXUS F721V1-1EN Leu, 2015-11-13 FLUXUS F721 Technical Specification Number of Sound Paths The number of sound paths is the number of transits of the ultrasonic signal through the medium in the pipe.
Technical Specification FLUXUS® F721 Liquid Ultrasonic Flowmeter for Permanent Installation For permanent outdoor wall or pipe mounting Features · Accurate and highly reliable bi-directional clamp-on volume and mass flow measurement (optional media temperature and pressure inputs) · Installation and commissioning without any invasive pipe work or process outages · Virtually unlimited measurement range, high measurement accuracy even at very low as well as very high flow rates and independent of the flow direction (bi-directional) · Possibility to measure thermal energy quantities when integrating clamp-on or inline temperature probes · User oriented configurations guarantee the optimal adaptation of the meter in regard to the individual application · Automatic loading of calibration data and transducer recognition · Bidirectional communication and support of common bus technologies (Profibus PA, Foundation Fieldbus, HART, Modbus, BACnet) · Easy parameterization of the device via connection of PC/laptop (Ethernet, USB) or within the SCADA system, even without external power supply · Extensive diagnostic functions for the evaluation of the measurement quality and process situation · Advanced self-diagnosis and possibilities for event based triggering of data recording for the supervision and control of critical processes · The transmitter is available with an aluminum or stainless steel enclosure (for especially corrosive environments). Both enclosures feature IP66 protection · Transmitter and transducers for usage in hazardous areas are available · Transmitter and transducers are separately calibrated (traceable to national standards), guaranteeing a specified measurement accuracy as well as the possibility for later exchange of components · Transducers for a wide range of inner pipe diameters (6...6500 mm, independent of the pipe wall thickness) and media temperatures (-190...+600 °C) are available · The measurement is zero point stable, drift free and independent of the pipe material, the internal pressurization and the flowing media · Highest reliability via Hybridtrek mode: automatic switch between transit time measurement principle and NoiseTrek guarantees exact and reliable measurement data even at slurries or liquids with high gaseous entrainments (>10 % of total volume) FLUXUS F721**-****A FLUXUS F721**-****S Applications · Chemical industry · Petrochemical industry · Oil and gas industry Measurement with transducers mounted by Variofix C · Pharmaceutical industry · Semiconductor industry · Manufacturing industries · Building technology/energy management · Water and wastewater industry · Mining industries TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 1 FLUXUS® F721 Table of Contents Technical Specification Function ........................................................................................................................................................... 3 Measurement Principle ..................................................................................................................................... 3 Calculation of Volumetric Flow Rate ................................................................................................................. 3 Number of Sound Paths.................................................................................................................................... 4 Flow Transmitter ............................................................................................................................................. 5 Technical Data .................................................................................................................................................. 5 Dimensions ....................................................................................................................................................... 8 2 " Pipe Mounting Kit (optional)......................................................................................................................... 9 Terminal Assignment ...................................................................................................................................... 10 Transducers................................................................................................................................................... 11 Transducer Selection ...................................................................................................................................... 11 Transducer Order Code .................................................................................................................................. 12 Technical Data ................................................................................................................................................ 13 Transducer Mounting Fixture ...................................................................................................................... 22 Coupling Materials for Transducers............................................................................................................ 24 Connection Systems..................................................................................................................................... 25 Transducer Cable............................................................................................................................................ 26 Junction Box ................................................................................................................................................. 27 Technical Data ................................................................................................................................................ 27 Dimensions ..................................................................................................................................................... 27 2 " Pipe Mounting Kit (optional)....................................................................................................................... 28 Terminal Assignment ...................................................................................................................................... 28 Clamp-on Temperature Probe (optional) .................................................................................................... 30 2 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification FLUXUS® F721 Function Measurement Principle Transit Time Difference Principle In order to measure the flow of a medium in a pipe, ultrasonic signals are used, employing the transit time difference principle. Ultrasonic signals are emitted by a transducer installed on the pipe and received by a second transducer. These signals are emitted alternately in the flow direction and against it. As the medium in which the signals propagate is flowing, the transit time of the ultrasonic signals in the flow direction is shorter than against the flow direction. The transit time difference, t, is measured and allows the flowmeter to determine the average flow velocity along the propagation path of the ultrasonic signals. A flow profile correction is then performed in order to obtain the area averaged flow velocity, which is proportional to the volumetric flow rate. Two integrated microprocessors control the entire measuring process. This allows the flowmeter to remove disturbance signals, and to check each received ultrasonic wave for its validity which reduces noise. HybridTrek If the gaseous or solid content in the medium increases occasionally during measurement, a measurement with the transit time difference principle is no longer possible. NoiseTrek mode will then be selected by the flowmeter. This measurement method allows the flowmeter to achieve a stable measurement even with high gaseous or solid content. The transmitter can switch automatically between transit time and NoiseTrek mode without any changes to the measurement setup. Path of the ultrasonic signal Calculation of Volumetric Flow Rate V· = kRe . A . ka . t/(2 . tfl) where V· - kRe A- ka t - tfl - volumetric flow rate fluid mechanics calibration factor cross-sectional pipe area acoustical calibration factor transit time difference transit time in the medium J J J Transit time difference t TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 3 FLUXUS® F721 Technical Specification Number of Sound Paths The number of sound paths is the number of transits of the ultrasonic signal through the medium in the pipe. Depending on the number of sound paths, the following methods of installation exist: · reflection arrangement The number of sound paths is even. Both of the transducers are mounted on the same side of the pipe. Correct positioning of the transducers is easier. · diagonal arrangement The number of sound paths is odd. Both of the transducers are mounted on opposite sides of the pipe. In the case of a high signal attenuation by the medium, pipe and coatings, diagonal arrangement with 1 sound path will be used. The preferred method of installation depends on the application. While increasing the number of sound paths increases the accuracy of the measurement, signal attenuation increases as well. The optimum number of sound paths for the parameters of the application will be determined automatically by the transmitter. As the transducers can be mounted with the transducer mounting fixture in reflection arrangement or diagonal arrangement, the number of sound paths can be adjusted optimally for the application. . a a - transducer distance Reflection arrangement, number of sound paths: 2 a Diagonal arrangement, number of sound paths: 3 a > 0 a < 0 Diagonal arrangement, number of sound paths: 1 Diagonal arrangement, number of sound paths: 1, negative transducer distance 4 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification Flow Transmitter Technical Data FLUXUS design F721**-NNN*A standard field device FLUXUS® F721 F721**-NNN*S F721**-A20*S field device with stainless steel housing measurement measurement principle transit time difference correlation principle, automatic NoiseTrek selection for measurements with high gaseous or solid content flow velocity 0.01...25 m/s repeatability 0.15 % of reading ±0.01 m/s medium all acoustically conductive liquids with < 10 % gaseous or solid content in volume (transit time difference principle) temperature compensation corresponding to the recommendations in ANSI/ASME MFC-5.1-2011 accuracy1 with standard calibration ±1.6 % of reading ±0.01 m/s with advanced calibration (optional) with field calibration2 ±1.2 % of reading ±0.01 m/s ±0.5 % of reading ±0.01 m/s flow transmitter power supply 100...230 V/50...60 Hz or 20...32 V DC or 11...16 V DC power consumption < 15 W number of flow measuring channels 1, optional: 2 damping 0...100 s, adjustable measuring cycle (1 channel) 100...1000 Hz response time 1 s (1 channel), option: 20 ms housing material aluminum, powder coated stainless steel 316L (1.4404) degree of protection IP66 according to IEC/EN 60529 IP66 dimensions see dimensional drawing weight 5.4 kg 5.1 kg fixation wall mounting, optional: 2 " pipe mounting ambient temperature -40...+60 °C (< -20 °C without operation of the display) display 128 x 64 dots, backlight menu language English, German, French, Spanish, Russian, Polish explosion protection transmitter - F721**-A20*S zone - 2 marking - A T E X certification ATEX - 0637 II3G II2D Ex nA nC ic IIC T4 Gc Ex tb IIIC T 120 °C Db Ta -40...+60 °C IBExU11ATEX1015 type of protection - gas: non sparking dust: protection by enclosure 1 for transit time difference principle, reference conditions and v > 0.15 m/s 2 reference uncertainty < 0.2 % TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 5 FLUXUS® F721 Technical Specification FLUXUS measuring functions physical quantities totalizer calculation functions diagnostic functions F721**-NNN*A F721**-NNN*S F721**-A20*S volumetric flow rate, mass flow rate, flow velocity, heat flow (if temperature inputs are installed) volume, mass, optional: heat quantity average, difference, sum (2 measuring channels necessary) sound speed, signal amplitude, SNR, SCNR, standard deviation of amplitudes and transit times data logger loggable values capacity all physical quantities, totalized values and diagnostic values max. 800 000 measured values communication (optional) process integration measured value transmission, configuration and parametrization (transmitter): Modbus TCP or HART or FF H1 or Profibus PA or diagnosis3 measured value transmission: RS485 (emitter) or Modbus RTU or BACnet MS/TP or BACnet IP measured value transmission, configuration and parametrization (transmitter): USB, Ethernet serial data kit (optional) software able FluxDiag: online diagnostics and report generation (min. Windows 7) USB cable3 outputs (optional) number The outputs are galvanically isolated from the transmitter. on request switchable current output (nonEx) All switchable current outputs are switched to active or passive mode at the same time. - range 4...20 mA (3.2...22 mA) - accuracy 0.04 % of reading ±3 A - active output - passive output Rext < 350 Uext = 8...30 V, depending on Rext, Rext < 1 k current output current output - range 0/4...20 mA - accuracy 0.1 % of reading ±15 A - active output - passive output current output I1 in HART Rext < 500 Uext = 4...24 V, depending on Rext, Rext < 1 k mode - range 4...20 mA - active output - passive output Uint = 24 V Uext = 10...24 V voltage output range 0...1 V or 0...10 V accuracy 0...1 V: 0.1 % of reading ±1 mV 0...10 V: 0.1 % of reading ±10 mV internal resistance Rint = 500 frequency output range 0...5 kHz open collector 24 V/4 mA, Rint = 66.5 binary output Reed relay optorelay 48 V/100 mA, Rint = 22 26 V/100 mA binary output as alarm output - functions limit, change of flow direction or error binary output as pulse output - pulse value 0.01...1000 units - pulse width optorelay: 1...1000 ms Reed relay: 80...1000 ms 3 outside of explosive atmosphere (housing cover open) 6 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification FLUXUS inputs (optional) number type connection range resolution accuracy accuracy active input - range passive input - range range accuracy internal resistance switching signal functions F721**-NNN*A F721**-NNN*S F721**-A20*S The inputs are galvanically isolated from the transmitter. max. 4, on request temperature input Pt100/Pt1000 4-wire -150...+560 °C 0.01 K ±0.01 % of reading ±0.03 K current input 0.1 % of reading ±10 A Uint = 24 V, Rint = 50 , Pint < 0.5 W, not short-circuit proof 0...20 mA Rint = 50 , Pint < 0.3 W -20...+20 mA voltage input 0...1 V 0.1 % of reading ±1 mV Rint = 1 M binary input 5...30 V, 1 mA FM class I, Div. 2: 5...26 V, 1 mA - resetting the measured values - resetting the totalizers - stopping the totalizers - activation of the measuring mode for highly dynamic flows FLUXUS® F721 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 7 FLUXUS® F721 Dimensions FLUXUS F721**-****A 94 Technical Specification wall mount Ø10.4 165.6 255 320 FLUXUS F721**-****S Ø8.5 thread: 6x M20 x 1.5 cable gland: max. 6x M20 190.2 87 fixing holes for wall mounting 240 280 255 in mm 8 320 cable gland: max. 6x M20 with flat gasket and counter nut TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification 2 " Pipe Mounting Kit (optional) FLUXUS F721**-****A FLUXUS F721**-****S FLUXUS® F721 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 9 FLUXUS® F721 Terminal Assignment FLUXUS F721 KL11 KL12 AV+ AV- S AR- AR+ BV+ BV- S BR- BR+ X_AV X_AR X2 X_BV X_BR X3 KL8 KL7 T1A T1B S1 T2A T2B T3A T3B S3 T4A T4B T1a T1b S1 T2a T2b T3a T3b S3 T4a T4b KL10 KL9 Technical Specification A+ B- P1+ P2+ P3+ P4+ P5a P6a P7a S S P1- P2- P3- P4- P5b P6b P7b KL4 PE N(-) L(+) F721**-****S F721**-****A equipotential bonding terminal power supply terminal strip KL4 terminal PE N(-) L(+) connection (AC) connection (DC) earth earth neutral - phase + transducers terminal strip KL11, KL12 extension cable (transducers *****8*, ****LI*, *****52) transducer cable (transducers *****8*, ****LI*) measuring channel A measuring channel B terminal connection terminal connection AV+ signal BV+ signal AV- shield BV- shield AR- shield BR- shield AR+ signal BR+ signal transducer cable (transducers *****52) measuring channel A measuring channel B terminal connection X_AV X_BV SMB connector X_AR X_BR SMB connector outputs1 terminal strip KL9, KL10 terminal P1+...P4+, P1-...P4- connection current output, voltage output, frequency output, binary output (Reed relay) P5a...P7a, P5b...P7b binary output (optorelay) RS485, Modbus RTU, BACnet MS/ TP, Profibus, FF (optional) terminal strip KL9, KL10 terminal A+ connection signal + B- signal - S shield analog inputs1 terminal strip KL7, KL8 terminal T1a...T4a T1A...T4A T1b...T4b T1B...T4B S1, S3 temperature probe direct connection connection with extension cable red red red/blue grey white/blue blue white white shield shield passive current source active current source connection of an active connection of a passive input input not connected not connected - + + not connected not connected - not connected not connected binary inputs1 terminal strip KL9, KL10 terminal P1+...P2+, P1-...P2- 1 The number, type and terminal assignment of the outputs and inputs will be customized. 10 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification FLUXUS® F721 Transducers Transducer Selection transducer order code FSG FSK FSM FSP FSQ FSS 6 50 25 50 10 25 10 70 5 10 50 recommended possible 400 500 100 200 100 200 600 150 400 100 500 6500 3600 6500 2000 3400 1000 5000 inner pipe diameter [mm] TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 11 FLUXUS® F721 Transducer Order Code 1, 2 3 4 5, 6 7, 8 9...11 12, 13 no. of character description Technical Specification transducer transducer frequency ambient temperature explosion protection connection system extension cable option FS G K M P Q S example FS M - N E -N - A1 A2 F2 NN TS XXX / LC IP68 OS set of ultrasonic flow transducers for liquids measurement, shear wave 0.2 MHz 0.5 MHz 1 MHz 2 MHz 4 MHz 8 MHz normal temperature range extended temperature range (shear wave transducers with transducer frequency M, P, Q) ATEX zone 1/IECEx zone 1 ATEX zone 2 FM Class I Div. 2 not explosion proof direct connection or connection via junction box cable length in m, for max. length of extension cable see page 25 0 m: without junction box > 0 m: with junction box JB01 (zone 1), JB02 (ATEX zone 2, FM), JB03 (not explosion proof), JBP2 (transducers IP68, ATEX zone 2), JBP3 (transducers IP68, not explosion proof) long transducer cable (only FSG, FSK) degree of protection IP68 with connection system TS housing with stainless steel 316 (with connection system TS) A1 TS - 030 - / shear wave transducer 1 MHz, normal temperature range, ATEX zone 1/IECEx zone 1, connection system TS with junction box JB01 and extension cable 30 m 12 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification Technical Data Shear Wave Transducers (zone 1) technical type CDG1N81 order code FSG-NA1TS FSG-NA1TS/OS transducer frequency MHz 0.2 CDK1N81 FSK-NA1TS FSK-NA1TS/OS 0.5 inner pipe diameter d min. extended mm min. recommended mm max. recommended mm max. extended mm pipe wall thickness min. mm max. mm material housing contact surface degree of protection according to IEC/ EN 60529 transducer cable type length m dimensions length l mm width b mm height h mm dimensional drawing 400 500 6500 6500 100 200 3600 6500 - - - - PEEK with stainless steel PEEK with stainless steel cap 304 (1.4301), option cap 304 (1.4301), option OS: 316L (1.4404) OS: 316L (1.4404) PEEK PEEK IP65 IP65 1699 5 129.5 51 67 1699 5 126.5 51 67.5 h h l l b b ambient temperature min. °C max. °C temperature compensation -40 +130 x explosion protection category zone gas: 2G 1 dust: 2D 21 explosion protection temperature (pipe surface) min. °C -55 A max. °C T marking E X / I certification ATEX E certification IECEx C type of protection E x transducer mounting fixture necessary +180 0637 II2G II2D Ex e q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x -40 +130 x gas: 2G 1 dust: 2D 21 -55 +180 0637 II2G II2D Ex e q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 FLUXUS® F721 13 FLUXUS® F721 Technical Specification technical type order code transducer frequency CDM2N81 FSM-NA1TS FSM-NA1TS/OS MHz 1 CDP2N81 FSP-NA1TS FSP-NA1TS/OS 2 CDQ2N81 FSQ-NA1TS FSQ-NA1TS/OS 4 inner pipe diameter d min. extended mm min. recommended mm max. recommended mm max. extended mm pipe wall thickness min. mm max. mm material housing contact surface degree of protection according to IEC/ EN 60529 transducer cable type length m dimensions length l mm width b mm height h mm dimensional drawing 50 25 10 100 50 25 2000 200 150 3400 600 400 - - - - - - PEEK with stainless steel PEEK with stainless steel PEEK with stainless steel cap 304 (1.4301), option cap 304 (1.4301), option cap 304 (1.4301), option OS: 316L (1.4404) OS: 316L (1.4404) OS: 316L (1.4404) PEEK PEEK PEEK IP65 IP65 IP65 1699 4 64 32 40.5 1699 4 64 32 40.5 1699 3 40 22 25.5 h h h l l l b b b ambient temperature min. °C max. °C -40 +130 temperature x compensation explosion protection category zone gas: 2G 1 dust: 2D 21 explosion protection temperature (pipe surface) min. °C -55 A max. °C T marking E X / I certification ATEX E certification IECEx C type of protection E x +180 0637 II2G II2D Ex e q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure transducer x mounting fixture necessary -40 +130 x gas: 2G 1 dust: 2D 21 -55 +180 0637 II2G II2D Ex e q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x -40 +130 x gas: 2G 1 dust: 2D 21 -55 +180 0637 II2G II2D Ex e q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x 14 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification FLUXUS® F721 Shear Wave Transducers (zone 1, IP68) technical type order code transducer frequency CDG1LI1 FSG-NA1TS/IP68 MHz 0.2 CDK1LI1 FSK-NA1TS/IP68 0.5 CDM2LI1 FSM-NA1TS/IP68 1 CDP2LI1 FSP-NA1TS/IP68 2 inner pipe diameter d min. extended mm min. recommended mm max. recommended mm max. extended mm pipe wall thickness min. mm max. mm material housing contact surface degree of protection according to IEC/ EN 60529 transducer cable type length m dimensions length l mm width b mm height h mm dimensional drawing 400 100 50 25 500 200 100 50 6500 3600 2000 200 6500 6500 3400 600 - - - - - - - - PEEK with stainless steel PEEK with stainless steel PEEK with stainless steel PEEK with stainless steel cap 316Ti (1.4571) cap 316Ti (1.4571) cap 316Ti (1.4571) cap 316Ti (1.4571) PEEK PEEK PEEK PEEK IP68 1 IP68 1 IP68 1 IP68 1 2550 12 130 54 83.5 2550 12 130 54 83.5 2550 12 72 32 46 2550 12 72 32 46 h h h h l l l l b b b b ambient temperature min. °C -40 max. °C +100 temperature x compensation explosion protection category zone gas: 2G 1 dust: 2D 21 explosion protection temperature (pipe surface) min. °C -55 A max. °C T E marking X / I E C certification ATEX certification IECEx E type of protection x +180 0637 II2G II2D Ex q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: powder filling dust: protection by enclosure transducer x mounting fixture necessary 1 test conditions: 3 months/2 bar (20 m)/20 °C -40 +100 x gas: 2G 1 dust: 2D 21 -55 +180 0637 II2G II2D Ex q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: powder filling dust: protection by enclosure x -40 +100 x gas: 2G 1 dust: 2D 21 -55 +180 0637 II2G II2D Ex q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: powder filling dust: protection by enclosure x -40 +100 x gas: 2G 1 dust: 2D 21 -55 +180 0637 II2G II2D Ex q IIC T6...T3 Gb Ex tb IIIC TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: powder filling dust: protection by enclosure x TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 15 FLUXUS® F721 Technical Specification Shear Wave Transducers (zone 1, extended temperature range) technical type order code transducer frequency CDM2E85 FSM-EA1TS FSM-EA1TS/OS MHz 1 CDP2E85 FSP-EA1TS FSP-EA1TS/OS 2 CDQ2E85 FSQ-EA1TS FSQ-EA1TS/OS 4 inner pipe diameter d min. extended mm min. recommended mm max. recommended mm max. extended mm pipe wall thickness min. mm max. mm material housing contact surface degree of protection according to IEC/ EN 60529 transducer cable type length m dimensions length l mm width b mm height h mm dimensional drawing 50 25 10 100 50 25 2000 200 150 3400 600 400 - - - - - - PI with stainless steel PI with stainless steel PI with stainless steel cap 304 (1.4301), option cap 304 (1.4301), option cap 304 (1.4301), option OS: 316L (1.4404) OS: 316L (1.4404) OS: 316L (1.4404) PI PI PI IP56 IP56 IP56 6111 4 64 32 40.5 6111 4 64 32 40.5 6111 3 40 22 25.5 h h h l l l b b b ambient temperature min. °C -30 max. °C +200 temperature x compensation explosion protection category zone gas: 2G 1 dust: 3D 22 explosion protection temperature (pipe surface) min. °C -45 A max. °C T marking E X / I certification ATEX E certification IECEx C type of protection E x +225 0637 II2G II2D Ex e q IIC T6...T2 Gb Ex tb IIIA TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure transducer x mounting fixture necessary -30 +200 x gas: 2G 1 dust: 3D 22 -45 +225 0637 II2G II2D Ex e q IIC T6...T2 Gb Ex tb IIIA TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x -30 +200 x gas: 2G 1 dust: 3D 22 -45 +225 0637 II2G II2D Ex e q IIC T6...T2 Gb Ex tb IIIA TX Db IBExU07ATEX1168 X IECEx IBE 08.0007X gas: increased safety, powder filling dust: protection by enclosure x 16 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification FLUXUS® F721 Shear Wave Transducers (ATEX zone 2, FM or not explosion proof) technical type order code CDG1N52 FSG-NA2TS CLG1N52 FSG-NA2TS/LC CDK1N52 FSK-NA2TS CLK1N52 FSK-NA2TS/LC FSG-NA2TS/OS FSG-NF2TS FSG-NA2TS/LC/OS FSG-NF2TS/LC FSK-NA2TS/OS FSK-NF2TS FSK-NA2TS/LC/OS FSK-NF2TS/LC FSG-NF2TS/OS FSG-NF2TS/LC/OS FSK-NF2TS/OS FSK-NF2TS/LC/OS FSG-NNNTS FSG-NNNTS/OS transducer frequency MHz 0.2 FSG-NNNTS/LC FSG-NNNTS/LC/OS 0.2 FSK-NNNTS FSK-NNNTS/OS 0.5 FSK-NNNTS/LC FSK-NNNTS/LC/OS 0.5 inner pipe diameter d min. extended mm min. recommended mm max. recommended mm max. extended mm 400 500 6500 6500 400 500 6500 6500 100 200 3600 6500 100 200 3600 6500 pipe wall thickness min. mm - - - - max. mm - - - - material housing contact surface degree of protection according to IEC/ EN 60529 PEEK with stainless steel PEEK with stainless steel PEEK with stainless steel PEEK with stainless steel cap 304 (1.4301), option cap 304 (1.4301), option cap 304 (1.4301), option cap 304 (1.4301), option OS: 316L (1.4404) OS: 316L (1.4404) OS: 316L (1.4404) OS: 316L (1.4404) PEEK PEEK PEEK PEEK IP67 IP67 IP67 IP67 transducer cable type length 1699 m5 1699 9 1699 5 1699 9 dimensions length l width b height h dimensional drawing mm 129.5 mm 51 mm 67 129.5 51 67 126.5 51 67.5 126.5 51 67.5 h h h h l l l l b b b b ambient temperature min. °C max. °C temperature compensation -40 +130 x -40 +130 x -40 +130 x -40 +130 x explosion protection order code category zone FSG-NA2TS FSG-NA2TS/OS gas: 3G dust: 3D 2 22 FSG-NA2TS/LC FSG-NA2TS/LC/OS gas: 3G dust: 3D 2 22 FSK-NA2TS FSK-NA2TS/OS gas: 3G dust: 3D 2 22 FSK-NA2TS/LC FSK-NA2TS/LC/OS gas: 3G dust: 3D 2 22 explosion protection temperature (pipe surface) min. °C -55 -55 -55 -55 max. °C +190 +190 +190 +190 A marking T II3G Ex nA IIC T6...T3 Gc II3G Ex nA IIC T6...T3 Gc II3G Ex nA IIC T6...T3 Gc II3G Ex nA IIC T6...T3 Gc E Ta -55...+190 °C Ta -55...+190 °C Ta -55...+190 °C Ta -55...+190 °C X II3D Ex tc IIIC TX Dc II3D Ex tc IIIC TX Dc II3D Ex tc IIIC TX Dc II3D Ex tc IIIC TX Dc certification - - - - type of protection gas: non sparking gas: non sparking gas: non sparking gas: non sparking dust: protection by dust: protection by dust: protection by dust: protection by enclosure enclosure enclosure enclosure transducer x x x x mounting fixture necessary order code FSG-NF2TS FSG-NF2TS/LC FSK-NF2TS FSK-NF2TS/LC FSG-NF2TS/OS FSG-NF2TS/LC/OS FSK-NF2TS/OS FSK-NF2TS/LC/OS explosion protection temperature F M min. max. marking °C -40 -40 -40 -40 °C +125 +125 +125 +125 NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 Temp. Codes dwg 3860 Temp. Codes dwg 3860 Temp. Codes dwg 3860 type of protection non incendive non incendive non incendive non incendive TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 17 FLUXUS® F721 technical type CDS1N52 order code FSS-NF2TS FSS-NNNTS transducer frequency MHz 8 inner pipe diameter d min. extended mm 6 min. recommended mm 10 max. recommended mm 70 max. extended mm 70 pipe wall thickness min. max. mm mm - material housing stainless steel 304 (1.4301) contact surface PEI degree of protection according to IEC/ EN 60529 IP65 transducer cable type length 1699 m2 dimensions length l mm 25 width b mm 13 height h mm 17 dimensional drawing h l b ambient temperature min. °C -30 max. °C +130 temperature x compensation explosion protection order code FSS-NF2TS explosion protection temperature F M min. max. marking °C -40 °C +125 NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 Technical Specification 18 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification Shear Wave Transducers (ATEX zone 2, FM or not explosion proof) technical type order code transducer frequency CDM2N52 FSM-NA2TS FSM-NA2TS/OS FSM-NF2TS FSM-NF2TS/OS FSM-NNNTS FSM-NNNTS/OS MHz 1 CDP2N52 FSP-NA2TS FSP-NA2TS/OS FSP-NF2TS FSP-NF2TS/OS FSP-NNNTS FSP-NNNTS/OS 2 CDQ2N52 FSQ-NA2TS FSQ-NA2TS/OS FSQ-NF2TS FSQ-NF2TS/OS FSQ-NNNTS FSQ-NNNTS/OS 4 inner pipe diameter d min. extended mm min. recommended mm max. recommended mm max. extended mm pipe wall thickness min. mm max. mm material housing contact surface degree of protection according to IEC/ EN 60529 transducer cable type length m dimensions length l mm width b mm height h mm dimensional drawing 50 25 10 100 50 25 2000 200 150 3400 600 400 - - - - - - PEEK with stainless steel PEEK with stainless steel PEEK with stainless steel cap 304 (1.4301), option cap 304 (1.4301), option cap 304 (1.4301), option OS: 316L (1.4404) OS: 316L (1.4404) OS: 316L (1.4404) PEEK PEEK PEEK IP67 IP67 IP67 1699 4 64 32 40.5 1699 4 64 32 40.5 1699 3 40 22 25.5 h h h l l l b b b ambient temperature min. °C max. °C temperature compensation -40 +130 x -40 +130 x -40 +130 x explosion protection order code FSM-NA2TS FSM-NA2TS/OS FSP-NA2TS FSP-NA2TS/OS FSQ-NA2TS FSQ-NA2TS/OS category zone gas: 3G 2 dust: 3D gas: 3G 22 2 dust: 3D gas: 3G 22 2 dust: 3D 22 explosion protection temperature (pipe surface) min. °C -55 -55 -55 max. °C +190 +190 +190 A marking T E X certification type of protection II3G Ex nA IIC T6...T3 Gc II3G Ex nA IIC T6...T3 Gc II3G Ex nA IIC T6...T3 Gc Ta -55...+190 °C Ta -55...+190 °C Ta -55...+190 °C II3D Ex tc IIIC TX Dc II3D Ex tc IIIC TX Dc II3D Ex tc IIIC TX Dc - - - gas: non sparking gas: non sparking gas: non sparking dust: protection by dust: protection by dust: protection by enclosure enclosure enclosure transducer x x x mounting fixture necessary order code FSM-NF2TS FSM-NF2TS/OS FSP-NF2TS FSP-NF2TS/OS FSQ-NF2TS FSQ-NF2TS/OS explosion protection temperature min. F M max. marking °C -55 -55 -55 °C +190 +190 +190 NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 Temp. Codes dwg 3860 Temp. Codes dwg 3860 type of protection non incendive non incendive non incendive TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 FLUXUS® F721 19 FLUXUS® F721 Technical Specification Shear Wave Transducers (ATEX zone 2 or not explosion proof, IP68) technical type order code transducer frequency CDG1LI8 FSG-NA2TS/IP68 FSG-NNNTS/IP68 MHz 0.2 CDK1LI8 FSK-NA2TS/IP68 FSK-NNNTS/IP68 0.5 CDM2LI8 FSM-NA2TS/IP68 FSM-NNNTS/IP68 1 CDP2LI8 FSP-NA2TS/IP68 FSP-NNNTS/IP68 2 inner pipe diameter d min. extended mm min. recommended mm max. recommended mm max. extended mm pipe wall thickness min. mm max. mm material housing contact surface degree of protection according to IEC/ EN 60529 transducer cable type length m dimensions length l mm width b mm height h mm dimensional drawing 400 100 50 25 500 200 100 50 6500 3600 2000 200 6500 6500 3400 600 - - - - - - - - PEEK with stainless steel PEEK with stainless steel PEEK with stainless steel PEEK with stainless steel cap 316Ti (1.4571) cap 316Ti (1.4571) cap 316Ti (1.4571) cap 316Ti (1.4571) PEEK IP68 1 PEEK IP68 1 PEEK IP68 1 PEEK IP68 1 2550 12 130 54 83.5 2550 12 130 54 83.5 2550 12 72 32 46 2550 12 72 32 46 h h h h l l l l b b b b ambient temperature min. °C -40 -40 -40 -40 max. °C +100 +100 +100 +100 temperature x x x x compensation explosion protection order code FSG-NA2TS/IP68 FSK-NA2TS/IP68 FSM-NA2TS/IP68 FSP-NA2TS/IP68 category zone gas: 3G 2 dust: 3D gas: 3G 22 2 dust: 3D gas: 3G 22 2 dust: 3D gas: 3G 22 2 dust: 3D 22 explosion protection temperature (pipe surface) min. °C -40 -40 -40 -40 max. °C +90 +90 +90 +90 A marking T E X certification II3G Ex nA IIC T6...T5 Gc II3G Ex nA IIC T6...T5 Gc II3G Ex nA IIC T6...T5 Gc II3G Ex nA IIC T6...T5 Gc Ta -40...+90 °C Ta -40...+90 °C Ta -40...+90 °C Ta -40...+90 °C II3D Ex tc IIIC TX Dc II3D Ex tc IIIC TX Dc II3D Ex tc IIIC TX Dc II3D Ex tc IIIC TX Dc - - - - type of protection gas: non sparking dust: protection by enclosure gas: non sparking dust: protection by enclosure gas: non sparking dust: protection by enclosure gas: non sparking dust: protection by enclosure transducer x x x x mounting fixture necessary 1 test conditions: 3 months/2 bar (20 m)/20 °C 20 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification FLUXUS® F721 Shear Wave Transducers (extended temperature range, ATEX zone 2, FM or not explosion proof) technical type order code transducer frequency CDM2E52 FSM-EA2TS FSM-EA2TS/OS FSM-EF2TS FSM-EF2TS/OS FSM-ENNTS FSM-ENNTS/OS MHz 1 CDP2E52 FSP-EA2TS FSP-EA2TS/OS FSP-EF2TS FSP-EF2TS/OS FSP-ENNTS FSP-ENNTS/OS 2 CDQ2E52 FSQ-EA2TS FSQ-EA2TS/OS FSQ-EF2TS FSQ-EF2TS/OS FSQ-ENNTS FSQ-ENNTS/OS 4 inner pipe diameter d min. extended mm min. recommended mm max. recommended mm max. extended mm pipe wall thickness min. mm max. mm material housing contact surface degree of protection according to IEC/ EN 60529 transducer cable type length m dimensions length l mm width b mm height h mm dimensional drawing 50 25 10 100 50 25 2000 200 150 3400 600 400 - - - - - - PI with stainless steel PI with stainless steel PI with stainless steel cap 304 (1.4301), option cap 304 (1.4301), option cap 304 (1.4301), option OS: 316L (1.4404) OS: 316L (1.4404) OS: 316L (1.4404) PI PI PI IP56 IP56 IP56 6111 4 64 32 40.5 6111 4 64 32 40.5 6111 3 40 22 25.5 h h h l l l b b b ambient temperature min. °C max. °C -30 +200 -30 +200 -30 +200 temperature x x x compensation explosion protection order code category zone FSM-EA2TS FSM-EA2TS/OS gas: 3G dust: 3D 2 22 FSP-EA2TS FSP-EA2TS/OS gas: 3G dust: 3D 2 22 FSQ-EA2TS FSQ-EA2TS/OS gas: 3G dust: 3D 2 22 explosion protection temperature (pipe surface) min. °C -45 -45 -45 max. °C +235 +235 +235 A marking T II3G Ex nA IIC T6...T2 Gc II3G Ex nA IIC T6...T2 Gc II3G Ex nA IIC T6...T2 Gc E Ta -45...+235 °C Ta -45...+235 °C Ta -45...+235 °C X II3D Ex tc IIIB TX Dc II3D Ex tc IIIB TX Dc II3D Ex tc IIIB TX Dc certification type of protection transducer mounting fixture necessary order code gas: non sparking dust: protection by enclosure x FSM-EF2TS FSM-EF2TS/OS gas: non sparking dust: protection by enclosure x FSP-EF2TS FSP-EF2TS/OS gas: non sparking dust: protection by enclosure x FSQ-EF2TS FSQ-EF2TS/OS explosion protection temperature min. F M max. marking °C -45 -45 -45 °C +235 +235 +235 NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / NI/Cl. I,II,III/Div. 2 / GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ GP A,B,C,D,E,F,G/ Temp. Codes dwg 3860 Temp. Codes dwg 3860 Temp. Codes dwg 3860 type of protection non incendive non incendive non incendive TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 21 FLUXUS® F721 Transducer Mounting Fixture Order Code 1, 2 3 4 5 6 7...9 10, 11 no. of character description Technical Specification transducer mounting fixture transducer measuremen t arrangement size fixation outer pipe diameter option - - / VL Variofix L V Variofix C WI transducer box for WaveInjector K transducers with transducer frequency G, K M transducers with transducer frequency M, P Q transducers with transducer frequency Q S transducers with transducer frequency S D reflection arrangement or diagonal arrangement R reflection arrangement S small M medium L large S tension straps W welding N without fixation 002 10...20 mm 004 20...40 mm T36 40...360 mm 013 10...130 mm 036 130...360 mm 092 360...920 mm 200 920...2000 mm 450 2000...4500 mm 940 4500...9400 mm NDR any IP68 degree of protection IP68 OS housing with stainless steel 316 Z special design example VL M -D S -S 200 Variofix L and tension straps for transducers with transducer frequency M, P - - / 22 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification Variofix L (VLS) FLUXUS® F721 Variofix L (VLK, VLM, VLQ) Variofix C (VC) transducer box WI for WaveInjector transducer box transducers: CDS1N52 material: stainless steel 304 (1.4301), 303 (1.4305) material: stainless steel 304 (1.4301), 301 (1.4310), 410 (1.4006) option OS: 316 (1.4571), 316L (1.4404), 17-7PH (1.4568) inner length: VLK: 348 mm, option IP68: 368 mm VLM: 234 mm VLQ: 176 mm dimensions: VLK: 423 x 90 x 93 mm, option IP68: 443 x 94 x 105 mm VLM: 309 x 57 x 63 mm VLQ: 247 x 43 x 47 mm material: stainless steel 304 (1.4301), 301 (1.4310) option OS: 316 (1.4571) inner length: VCK-*L: 500 mm VCK-*S: 350 mm VCM: 400 mm VCQ: 250 mm dimensions: VCK-*L: 560 x 122 x 102 mm, option IP68: 560 x 126 x 120 mm VCK-*S: 410 x 122 x 102 mm, option IP68: 410 x 126 x 120 mm VCM: 460 x 96 x 80 mm VCQ: 310 x 85 x 62 mm see Technical Specification TSWaveInjectorVx-x TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 23 FLUXUS® F721 Technical Specification Coupling Materials for Transducers < 24 h long time measurement 1 < 5 years 2 < 6 months normal temperature range extended temperature range WaveInjector WI-400 (4th character of transducer order (4th character of transducer order code = N) code = E) < 100 °C < 170 °C < 150 °C < 200 °C < 280 °C 280...400 °C coupling com- coupling com- coupling com- coupling com- coupling foil coupling foil pound type N or pound type E or pound type E or pound type E or H type A and type B and coupling foil coupling foil coupling foil or coupling foil coupling foil coupling foil type VT type VT type VT type VT type VT type VT coupling foil type VT1 coupling foil type VT2 coupling foil type VT1 coupling foil type VT2 coupling foil type A and coupling foil type B and coupling foil coupling foil type VT type VT Technical Data type order code coupling compound 990739-1 type N coupling compound 990739-2 type E coupling compound 990739-3 type H coupling foil type A 990739-7 coupling foil type B 990739-8 coupling foil type VT 990739-0 990739-6 990739-14 990739-5 ambient temperature material °C -30...+130 mineral grease paste -30...+200 silicone paste -30...+250 fluoropolymer paste max. 280 lead > 280...400 silver -10...+200 fluoroelastomer remark for transducers with transducer frequency G, H, K for shear wave transducers with transducer frequency M, P for shear wave transducers IP68 and Lambwave transducers with transducer frequency M, P for transducers with transducer frequency Q 24 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification Connection Systems connection system TS connection with extension cable JB01 x l JB01, JBP2, JBP3 x transmitter transmitter FLUXUS® F721 direct connection x transducers technical type *****8* ****LI* x transmitter transmitter l JB02, JB03 x *****52 x transmitter transmitter l transducer frequency G, H, K M, P Q S (3d character of transducer order code) x l x l x l x l T cable length m 5 300 4 300 3 90 2 40 S cable length (option LC) m 9 300 - - - - - - cable length (option IP68) m 12 300 12 300 - - - - x - transducer cable length l - max. length of extension cable TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 25 FLUXUS® F721 Technical Specification Transducer Cable Technical Data type standard length max. length ambient temperature properties cable jacket material outer diameter thickness colour shield sheath material outer diameter 1699 m see table above m°C -55...+200 transducer cable 2550 (option IP68) 6111 -40...+100 longitudinal water tight -100...+225 2615 extension cable 5245 see table above -40...+70 halogen free -30...+70 halogen free fire propagation test fire propagation test according to according to IEC 60332-1 IEC 60332-1 combustion test according to IEC 60754-2 combustion test according to IEC 60754-2 PTFE mm 2.9 mm 0.3 brown x PUR 5.2 ±0.2 0.9 grey x PFA 2.7 0.5 white x PUR 12 2 black x PUR 12 2 black x stainless steel 304 - (1.4301) option OS: 316L (1.4404) mm 8 - stainless steel 304 - (1.4301) option OS: 316L (1.4404) 8 - steel wire braid with copolymer sheath 15.6 26 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification FLUXUS® F721 Junction Box Technical Data technical type dimensions fixation material housing gasket degree of protection according to IEC/ EN 60529 ambient temperature min. °C max. °C explosion protection zone marking A T E X / I E certification ATEX certification IECEx C type of protection E x JB01S4E3M see dimensional drawing wall mounting, optional: 2 " pipe mounting JB02 see dimensional drawing wall mounting, optional: 2 " pipe mounting JB03 see dimensional drawing wall mounting, optional: 2 " pipe mounting JBP2 see dimensional drawing wall mounting, optional: 2 " pipe mounting JBP3 see dimensional drawing wall mounting, optional: 2 " pipe mounting stainless steel 316L stainless steel 316L stainless steel 316L stainless steel 316L stainless steel 316L (1.4404) (1.4404) (1.4404) (1.4404) (1.4404) silicone silicone silicone silicone silicone IP67 IP67 IP67 IP67 IP67 -40 -40 -40 +80 +80 +80 1 2 - 0637 II2G II2D II3G Ex nA IIC - Ex e mb IIC (T6)...T4 Gc (T6)...T4 Gb II3D Ex tc IIIC Ex tb IIIC T 100 °C T 100 °C Dc Db Ta -40...+(70)80 °C Ta -40...+(70)80 °C IBExU06ATEX1161 - - IECEx IBE 08.0006 - - gas: gas: non sparking - · increased safety dust: protection by · decoupled network: enclosure encapsulation dust: protection by enclosure -40 -40 +80 +80 2 - - II3G Ex nA IIC (T6)...T4 Gc II3D Ex tc IIIC T 100 °C Dc Ta -40...+(70)80 °C - - - - gas: non sparking - dust: protection by enclosure Dimensions wall mounting holder 156 174 in mm 70 Ø 9 163.5 2 119 thread: 3x M20 x 1.5 cable gland: max. 2x M20 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 27 FLUXUS® F721 2 " Pipe Mounting Kit (optional) Technical Specification Terminal Assignment JB01 TR TR S TR TG TG TVS TVS TV K L2 K L1 shield terminal equipotential bonding terminal (at wall mounting holder) JB02, JB03 TR S TG TG TV K L2 XV XR shield terminal equipotential bonding terminal (at wall mounting holder) V VS RS R transducers terminal strip KL1 terminal V VS RS R cable gland extension cable terminal strip KL2 terminal TV TVS TRS TR shield terminal connection transducer , signal transducer , internal shield transducer , internal shield transducer , signal external shield connection signal internal shield internal shield signal external shield transducers terminal XV XR cable gland extension cable terminal strip KL2 terminal TV TVS TRS TR shield terminal connection transducer , SMB connector transducer , SMB connector external shield connection signal internal shield internal shield signal external shield 28 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification JBP2, JBP3 TV TVS TG TG TR S TR TV TVS TR S TR K L2 K L1 shield terminal equipotential bonding terminal (at wall mounting holder) FLUXUS® F721 transducers terminal strip KL1 terminal TV TVS TRS TR cable gland extension cable terminal strip KL2 TV TVS TRS TR terminal shield terminal connection transducer , signal transducer , internal shield transducer , internal shield transducer , signal external shield connection signal internal shield internal shield signal external shield TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 29 FLUXUS® F721 Technical Specification Clamp-on Temperature Probe (optional) Technical Data technical type order code design type connection measuring range °C accuracy T accuracy T response time s housing PT12N 670415-1 770415-1 PT12N 670414-1 770414-1 Pt100 2x Pt100 matched according to EN 1434-1 4-wire -30...+250 ±(0.15 °C + 2 . 10-3 . |T [°C]|) class A - 0.1 K (3 K < T < 6 K), more corre- sponding to EN 1434-1 50 aluminum PT12N 770415-1A2 PT12N 770414-1A2 ATEX zone 2 Pt100 2x Pt100 matched according to EN 1434-1 4-wire -30...+250 ±(0.15 °C + 2 . 10-3 . |T [°C]|) class A - 0.1 K (3 K < T < 6 K), more corre- sponding to EN 1434-1 50 aluminum degree of protection according to IEC/ IP66 EN 60529 weight (without kg 0.25 0.5 connector) fixation clamp-on accessories thermal conductivity paste 200 °C 670415-1: x 770415-1: - 670414-1: x 770414-1: - thermal conductivity foil 250 °C x x plastic protection plate, - - insulation foam dimensions length l mm 15 width b mm 15 height h mm 20 dimensional drawing 670415-1: A 770415-1: C 670414-1: A 770414-1: C explosion protection zone - A T E X explosion protection temperature min. °C max. °C marking - IP66 0.25 0.5 clamp-on - x - 15 15 20 C 2 -30 +250 II3G Ex nA IIC T6...T2 Gc Ta -30...+250 °C PT12F 670415-2 PT12F 670414-2 short response time Pt100 2x Pt100 matched according to EN 1434-1 4-wire -50...+250 ±(0.15 °C + 2 . 10-3 . |T [°C]|) class A - 0.1 K (3 K < T < 6 K), more corre- sponding to EN 1434-1 8 PEEK, stainless steel 304 (1.4301), copper IP66 0.32 0.64 clamp-on x x x 14 30 27 B - - l A h extension cable l l B h C h junction box extension cable C 30 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 Technical Specification Connection Temperature Probe red/blue red white/blue white FLUXUS® F721 Connector pin 1 2 3, 4, 5 6 7 8 cable of temperature probe white/blue red/blue not connected red white not connected extension cable blue grey red white Cable type standard length max. length cable jacket cable of temperature probe 4 x 0.25 mm² black or white m3 m- PTFE 2 4 5 8 1 3 6 7 extension cable LIYCY 8 x 0.14 mm² grey 5/10/25 200 PVC Junction Box technical type dimensions fixation material housing gasket degree of protection according to IEC/ EN 60529 cable gland ambient temperature min. °C max. °C explosion protection zone marking A T E X certification type of protection JBT2 see dimensional drawing wall mounting optional: 2 " pipe mounting stainless steel 316L (1.4404) silicone IP67 max. 2x M12 -40 +80 2 II3G Ex nA IIC (T6)...T4 Gc II3D Ex tc IIIC T 100 °C Dc Ta -40...+(70)80 °C gas: non sparking, dust: protection by enclosure JBT3 see dimensional drawing wall mounting optional: 2 " pipe mounting stainless steel 316L (1.4404) silicone IP67 max. 2x M12 -40 +80 - - TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 31 FLUXUS® F721 Terminal Assignment JBT2, JBT3 K L2 K L1 shield terminal equipotential bonding terminal (at wall mounting holder) 1 2 S S 3 4 1 2 3 4 Technical Specification temperature probe terminal strip KL1 terminal 1 2 3 4 red red/blue white white/blue connection extension cable terminal strip KL2 terminal 1 2 3 4 red grey white blue connection 32 TSFLUXUS_F721V1-1EN_Leu, 2015-11-13 FLUXUS® F721 Technical Specification FLEXIM GmbH Wolfener Str. 36 12681 Berlin Germany Tel.: +49 (30) 93 66 76 60 34 Fax: +49 (30) 93 66 76 80 internet: www.flexim.com e-mail: info@flexim.com Subject to change without notification. Errors excepted. FLUXUS® is a registered trademark of FLEXIM GmbH. TSFLUXUS_F721V1-1EN_Leu, 2015-11-13Acrobat Distiller 9.5.5 (Windows)