INSTRUCTION MANUAL
WIFI DONGLE FOR SOLAR INVERTER

MODEL

SKU

VT-660000 11378, 11528

INTRODUCTION
Thank you for selecting and buying V-TAC Product. V-TAC will serve you the best. Please read these instructions carefully & keep this user manual handy for future reference. If you have any another query, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best.
Multi-Language Manual QR CODE
Please scan the QR code to access the manual in multiple languages.
IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: SUPPORT@V-TAC.EU FOR MORE PRODUCTS RANGE, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST DEALERS. V-TAC EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B

ENGLISH

WARNING
1. Please make sure to turn off the power before starting the installation. 2. Installation must be performed by a qualified electrician.

This marking indicates that this product should not be disposed of with other household wastes.

Caution, risk of electric shock.

20
PAP
NOTICE: Please read this manual carefully before using products and keep it in the place where O&M providers can easily find.
Due to product upgrade and other factors, the content of this manual might change from time to time. Please take actual product as standard and get latest manual from www.vtacexports.com or sales. Unless otherwise agreed herein, this manual will only be used as guidance. Any statement, information or suggestion in this manual will not take any form of responsibility.
Without written permission, any content of this document (partly or entirely) cannot be extracted, copied or transmitted in any form by any company or individual.

DOWNLOAD APP

SOLARMAN Smart for end user

SOLARMAN Business for business

IOS: Search "SOLARMAN Smart" in Apple Store. Android: Search "SOLARMAN Smart" in Google Play.

ENGLISH

1. Stick Logger Installation

Type 1 Step1: Assemble logger to the inverter communication interface as shown in the diagram.

Type 2 Step1: Assemble logger to the inverter communication interface as shown in the diagram.

Warning: Please do not hold the logger body to rotate while install or remove the logger.

Logger Status

Check Indicator light

Lights NET

Implication Status Description(All lights are single green lights.)
1.Light off: Connection to the router failed. Communication 2.On 1s/Off 1s(Slow flash): Connection to the router succeeded.
with router 3.Light keeps on: Connection to the server succeeded. 4.On 100ms/Off 100ms(Fast flash): Distributing network fast.

COM

Communication with inverter

1.Light keeps on: Logger connected to the inverter. 2.Light off: Connection to the inverter failed. 3.On 1s/Off 1s(Slow flash): Communicating with inverter.

READY

Logger running status

1.Light off: Running abnormally. 2.On 1s/Off 1s (Slow flash): Running normally. 3.On 100ms/Off 100ms(Fast flash): Restore factory settings.

The normal operation status of the stick logger, when router connected to the network normally: 1.Connection to the server succeeded: NET light keeps on after the logger powered on. 2.Logger running normally: READY light flashes. 3.Connection to the inverter succeeded: COM light keeps on.

ENGLISH

ABNORMAL STATE PROCESSING
If the data on platform is abnormal when the stick logger is running, please check the table below and according to the status of indicator lights to complete a simple troubleshooting. If it still can not be resolved or indicator lights status do not show in the table below, please contact Customer Support. (Note: Please using the following table query after power-on for 2mins at least.)

NET NET Any state
OFF
Slow flash
OFF
Fast flash Any state

COM READY

Fault Description COM READY

Fault Cause

Solution

OFF

Slow flash

Communication with inverter abnormal

1.Connection between stick logger and inverter loosen. 2.Inverter does not match with stick logger's communication rate.

1.Check the connection between stick logger and inverter. Remove the stick logger and install again. 2.Check inverter's communication rate to see if it matches with stick logger's. 3.Long press Reset button for 5s, reboot stick logger.

1.Check if the wireless network

configured.

1.Stick logger does 2.Check the antenna, if there is any

ON

Slow flash

Connection between not have a network. damage or loose.

logger and router 2.Antenna abnormal 3.Enhance router WiFi signal

abnormal

3.Router WiFi signal strength.

strength weak.

4.Long press Resetbutton for 10s,

reboot stick logger and networking

again.

ON
OFF
Any state Any state

Slow flash
OFF
Any state

Connection between logger and router normal, connection between logger and
remote server abnormal.

1.Router networking abnormal. 2.The server point of logger is modified. 3.Network limitation, server cannot be connected.

1.Check if the router has access to the network. 2.Check the router's setting, if the connection is limited. 3.Contact our customer service.

Power supply abnormal

1.Connection betw-

een stick logger and

inverter loosen or 1.Check the connection, remove the

abnormal.

stick logger and install again.

2.Inverter power in- 2.Check inverter output power.

sufficient.

3.Contact our customer service.

3.Stick Logger abn-

ormal.

SMARTLINK networking status

Normal

1.Exit automatically after 5mins. 2.Long press Reset button for 5s, reboot stick logger. 3.Long press Reset button for 10s, restore factory settings.

Fast flash

Restore factory settings

Normal

1.Exit automatically after 1mins. 2.Long press Reset button for 5s, reboot stick logger. 3.Long press Reset button for 10s, restore factory settings.

ENGLISH

USAGE METHODS AND NOTICES FOR RESET BUTTON Usage methods and key-press descriptions for Reset button

Usage: Press

Key-press

Status Descripon

Short press 1s SMARTLINK rapid networking status.

Long press 5s

Reboong the sck logger.

Long press 10s

Reseng the sck logger.

Light Status
NET light flashes fast for 100ms. All lights are exnguished immediately.
1.All lights are exnguished aer 4s. 2.READY light flashes fast for 100ms.

NOTICES FOR RESET BUTTON

Notice: Do not remove waterproof plug.

USER MANUAL FOR SOLARMAN SMART APP
1.Registration Go to SOLARMAN Smart and register. Click "Register" and create your account here.

2.Create a Plant Click "Add Now" to create your plant. Please fill in plant basic info and other info here.

3.Add a Logger Method 1: Enter logger SN manually. Method 2: Click the icon in the right and scan to enter logger SN You can find logger SN in the external packaging or on the logger body.
4.Network Configuration After the logger is added, please configure the network to ensure normal operation. Go to "Plant Details"-"Device List", find the target SN and click "Networking".
Step 1Confirm Wi-Fi Info Please make sure your phone has connected to the right WiFi network. And click "Start". Notice: 5G WiFi is not supported .

ENGLISH

Step 2Connect to AP network Click "Go to connect" and find the right "AP_XXXXX" network (XXXXX Refers to logger SN).
If the password is required, you can find the password on the logger body. Go back to SOLARMAN Smart APP, after connecting to AP network.

ENGLISH

Step 3Auto Configuration Please wait for a while to complete the configuration. Then system will switch to the following page. Click "Done" to check plant data. (Usually, the data will be updated in 10 mins)
Warning: Please make sure the stick logger is working properly before you leave the site. If there is anything abnormal, please do not leave the site and contact customer service



References