Conext Gateway Owner's Guide (975-0806-01-01)
SE Solar
Conext Gateway Owner's Guide (975-0806-01-01)
243006920-20Schneider20Conext20Gateway20Pro20Installation ConextTM Gateway
Conext Gateway Owner's Guide
975-0806-01-01 January 2019
http://solar.schneider-electric.com/
Copyright © 2019 Schneider Electric. All Rights Reserved.
Google Chrome, Microsoft, Windows, and Internet Explorer used with permission from Microsoft. Safari and Mac OS are trademarks of Apple Inc., registered in the U.S. and other countries. All other trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
Exclusion for Documentation
UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER
(A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION;
(B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER'S RISK; AND
(C) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. APPROVED CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT http://solar.schneider-electric.com/.
Document Number: 975-0806-01-01 Part Number: 865-0329
Date: January 2019
Contact Information For country-specific details, please contact your local Schneider Electric Sales Representative or visit the Schneider Electric Solar Business website at: http://solar.schneider-electric.com/ Information About Your System As soon as you open your product, record the following information and be sure to keep your proof of purchase.
Serial Number Product Number Purchased From Purchase Date
____________________________ ____________________________ ____________________________ ____________________________
Safety Information
Important Information
Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of either symbol to a "Danger" or "Warning" safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Please Note
NOTICE
NOTICE is used to address practices not related to physical injury.
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to the construction, installation, and operation of electrical equipment and has received safety training to recognize and avoid the hazards involved. For more information, see Audience.
Product Safety Information
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, ARC FLASH, AND FIRE n Read all instructions, cautionary markings, and all other appropriate sections of this guide
before installing, operating, troubleshooting or performing maintenance on the Conext Gateway. n Exercise extreme caution at all times to prevent accidents. n These instructions are for use by qualified installers only. Failure to follow these instructions will result in death or serious injury.
DANGER
HAZARD OF ELECTRIC SHOCK AND FIRE n Connect only to Safety Extra Low Voltage (SELV) circuits and power sources. n All wiring must be done by qualified personnel to ensure compliance with all applicable
installation codes and regulations. n For Indoor Use Only. n Do not disassemble. No user serviceable parts inside. Failure to follow these instructions will result in death or serious injury.
NOTICE
EQUIPMENT DAMAGE n All cables connected to the Conext Gateway must run indoors and not be susceptible to
lightning strikes.
n Turn OFF all devices before connecting cables. The Conext Gateway does not have an ON/OFF switch.
n Do not connect an Ethernet cable from the Conext Gateway to the WAN/MODEM port on the network router.
n Do not connect an Ethernet cable plug into a Xanbus port on the Conext Gateway.
n Do not connect a Xanbus RJ-45 cable plug into the 10/100 Ethernet port of theConext Gateway.
n Do not connect any port on the Conext Gateway to an outside line or to a public telecommunication network.
n Ensure that the device connected on the Xanbus network is in standby mode before changing settings. Do not change any settings unless you are familiar with the device.
n Changes to any TCP/IP-related settings should only be performed by a qualified IT professional.
Failure to follow these instructions can result in equipment damage or affect network performance.
NOTICE
EQUIPMENT DAMAGE n Do not disassemble the Conext Gateway.
n See Warranty for instructions on obtaining service.
n The Conext Gateway contains no user serviceable parts. Attempting to service the Conext Gateway yourself will void your warranty.
Failure to follow these instructions can result in equipment damage.
NOTE: This device can be configured to connect to the Internet using port-forwarding in your network router's settings. There is a security risk in port-forwarding unencrypted network traffic over a public network (Internet). Use of a VPN or a secure tunnel to route Conext Gateway communication via the Internet is recommended.
Audience
This guide is intended for use by anyone who plans to install and operate the Conext Gateway communications device as part of their power plant system. Installation instructions are meant for installers only. The installers have training, knowledge, and experience in:
n Installing electrical equipment. n Applying all applicable installation codes. n Analyzing and reducing the hazards involved in performing electrical work. n Selecting and using Personal Protective Equipment (PPE). n Changing any TCP/IP-related settings.
Configuration, servicing, and maintenance must be performed by authorized service personnel only. Authorized service personnel meet the requirements for an installer, plus they have received specific training from the manufacturer on servicing the Conext Gateway.
About
Purpose
The purpose of this Owner's Guide is to provide explanations and procedures for installing, operating, configuring, maintaining, and troubleshooting the Conext Gateway.
Scope
The Owner's Guide provides safety guidelines, planning, and setup information, procedures for installing the product, as well as information about troubleshooting the product. It does not include information on how to install, configure and use other Schneider Electric products.
Firmware Revision
Some Conext Gateway features and functions described in this Owner's Guide may be incorporated with later firmware versions. This Owner's Guide is valid for Conext Gateway Version 1.01 and above. To view the firmware version on your product, see the Conext Gateway Status Information in the web user interface.
Abbreviations and Acronyms
DHCP LED SELV TCP/IP
Dynamic host configuration protocol Light emitting diode (used for indicator lights) Safety extra low voltage Transmission control protocol/Internet protocol
Related Products
For more information about related products, refer to:
n Conext XW Pro Inverter/Charger Owner's Guide (part number: depends on configuration - see http://solar.schneider-electric.com/)
n Conext XW+ Inverter/Charger Owner's Manual (part number: depends on configuration see http://solar.schneider-electric.com/)
n Conext Automatic Generator Start (AGS) Owner's Guide (part number: 975-0307-01-01)
n Conext System Control Panel (SCP) Owner's Guide (part number: 975-0298-01-01)
n Conext SW Inverter/Charger Owner's Guide (part number: depends on configuration see http://solar.schneider-electric.com/)
n Conext MPPT 80 600 Solar Charge Controller Operation Guide (part number: 975-054001-01)
n Conext MPPT 60 150 Solar Charge Controller Operation Guide (part number: 975-0400-
01-01) n Conext Battery Monitor Owner's Manual (part number: 975-0691-01-01)
Related Information
You can find more information about Schneider Electric's Solar products, as well as its services at http://solar.schneider-electric.com/.
Contents
Safety Information
2
Audience
5
About
6
Purpose
6
Scope
6
Firmware Revision
6
Abbreviations and Acronyms
6
Related Products
6
Related Information
7
Overview
10
Introduction
11
Compatible XanbusTM Components
11
Material List
12
Physical Features
13
Power Button Operation
14
LED Indicator Operation
14
26-pin Connector Pinouts
15
Types of Conext Gateway Networks
16
Power Sources for the Conext Gateway
16
Conext Gateway Web User Interface
17
Installation
20
Choosing a Location
21
Materials and Tools Required
22
Mounting the Conext Gateway
23
Wall Mount
23
DIN Rail Mount
23
Connecting the Conext Gateway to the Xanbus Network
24
Connecting the Conext Gateway to the Internet
26
Turning On the Conext Gateway
28
Turning Off the Conext Gateway
29
Power Cycling
29
Configuration
30
Using the Conext Gateway Web App via Wi-Fi Access Point (AP)
31
Web Security
32
Configuring the Conext Gateway
32
Logging in to the Conext Gateway Web Application
34
Changing the Password
35
Changing Conext Gateway Settings
37
Plant Setup
38
Time Setup
38
Import and Export Settings
39
Units
40
Modbus Settings
40
Restarting the Conext Gateway
41
Install Package
42
Changing Device Settings
43
Upgrading Firmware
45
Installing Conext Gateway Upgrades From a USB Drive
45
Installing Conext Gateway Upgrades Remotely
46
Upgrading Other Device Firmware
46
Monitoring
48
Monitoring LED Indicators
49
Startup
49
Monitoring the Power Plant
49
Troubleshooting
52
Events
53
Specifications
56
Electrical Specifications
57
Physical Specifications
57
Features
58
Regulatory
58
FCC Regulatory Compliance
58
ISED Regulatory Compliance
59
Simplified EU Declaration of Conformity
60
Schneider Electric Products that Work with the Conext Gateway
60
Dimensions
61
Using Chrome to Install the Conext GatewaySecurity Certificate
62
Installing the Conext Gateway Security Certificate
63
Overview
Conext Gateway Conext Gateway Owner's Guide
1 Overview
What's in This Chapter?
Introduction
11
Compatible XanbusTM Components
11
Material List
12
Physical Features
13
Power Button Operation
14
LED Indicator Operation
14
26-pin Connector Pinouts
15
Types of Conext Gateway Networks
16
Power Sources for the Conext Gateway
16
Conext Gateway Web User Interface
17
Conext Gateway Conext Gateway Owner's Guide
Overview
Introduction
The Conext Gateway is a multi-function communication device that provides an overall view of system performance for residential power monitoring systems. It also provides a communications gateway between a network of XanbusTM-enabled devices and Modbus devices. Operators can configure the Conext Gateway system and monitor performance with third party software packages and building management systems.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, ARC FLASH, AND FIRE
n Connect only to Safety Extra Low Voltage (SELV) circuits and power sources. n All wiring must be done by qualified personnel to ensure compliance with all
applicable installation codes and regulations. n For Indoor Use Only. n Do not disassemble. No user serviceable parts inside.
Failure to follow these instructions will result in death or serious injury.
Other features of the Conext Gateway include: n Compatibility--connects directly to Xanbus-enabled devices n Real-time clock--keeps time for the entire system n Non-volatile memory--preserves the latest Conext Gateway settings if power is
interrupted or network communication is disrupted. n Firmware storage and upgrade capability--uses the Conext Gateway to upgrade or
downgrade firmware for Xanbus-enabled devices on the network. n Cloud storage capability--Save and synchronize settings with the Conext Gateway
cloud service.
Compatible XanbusTM Components
The Conext Gateway works with several Schneider Electric products including:
n Conext XW Pro Inverter/Charger n Conext XW+ Inverter/Charger n Conext Automatic Generator Start (AGS) n Conext System Control Panel (SCP) n Conext SW Inverter/Charger n Conext MPPT 80 600 Solar Charge Controller n Conext MPPT 60 150 Solar Charge Controller n Conext Battery Monitor
11
975-0806-01-01
Overview
Material List
Conext Gateway Conext Gateway Owner's Guide
For details on specific models supported, see Specifications on page 1. The Conext Gateway supports up to a maximum of 20 devices on a Xanbus network depending on the device types.
Figure 1 Material list
1
Attach the antennas before turning on the unit.
3
2
4
NOTE: n Do not discard the packaging box. n The Wi-Fi password is printed on the unit. n Install the antennas before turning on the unit.
1 2 3 4
not shown
Conext Gateway unit
AC/DC power adapter with interchangeable plugs
Ethernet cable (CAT5e)
Network terminator · 8GB Micro SD card · 75mm DIN rail · CAN terminator · 26-pin connector (see Physical Features on page 13)
975-0806-01-01
12
Conext Gateway Conext Gateway Owner's Guide
Overview
Physical Features
The following illustration shows the Conext Gateway. The tables in the following sections contain descriptions of the connectors, indicators, and data ports on the Conext Gateway.
Figure 2 Ports, buttons, and indicators
12 3
4
10
5
6 987
11 12 13 14
1 Xanbus ports 1 1st pair of Xanbus ports used for Xanbus communications
2 Xanbus ports 2 2nd pair of Xanbus ports used for Xanbus communications
3 Ethernet port Use to connect to the internet via an Ethernet cable.
4 Antenna
Adjustable antenna for Wi-Fi transmission and reception
5 26-pin port
Use for connecting the 26-pin connector.
6 LED indicators LED indicators are used for signifying device, communication, and monitoring statuses.
7 Wi-Fi button
Press and hold to turn on or turn off Wi-Fi setup network.
8 Settings button Press to enter device configuration mode.
9 Power button Press to enable/disable the Conext Gateway.
10 Power port
Use for connecting the AC/DC power plug.
11 DIN rail clip
Use for attaching the device to a 35mm EN50022 DIN rail. The clip
(detachable)
can be detached and re-attached to one of the narrow sides of the device.
12 Reset pinhole Press to reset the Conext Gateway. button
13 USB port
Use for firmware updates only. Do not use to charge USB devices.
14 SD card slot
Insert a mini-SD card (up to 128GB) for data storage.
13
975-0806-01-01
Overview
Conext Gateway Conext Gateway Owner's Guide
Power Button Operation
Table 1 Power button operation
Press and hold Number of
duration
beeps
Conext Gateway operation
3 seconds
1
Conext Gateway will restart
6 seconds
2
Conext Gateway will shutdown
9 seconds
3
User settings will be reset and Conext Gateway will restart
12 seconds
4
Factory default settings will be reset and Conext Gateway will restart
LED Indicator Operation
Figure 3 LED indicators
Green Power The Conext Gateway is powered on.
Green Memory Device is logging data to internal memory when flashing.
C Green Cloud Device is actively transferring data with the cloud.
X Green Xanbus Device is actively transferring data with a Xanbus device/s.
M Green Modbus Device is actively transferring data with a Modbus device/s.
! Red Event Devices on the Power system have events to
report. Blue Wi-Fi Wi-Fi connectivity is established.
975-0806-01-01
14
Conext Gateway Conext Gateway Owner's Guide
Overview
26-pin Connector Pinouts
Figure 4 26-pin connector
Bottom Row
2 924VDC power input 4 GND 6 12VDC digital input 1 8 12VDC digital input 2 10 ISO1 CAN GND 12 ISO1 CAN L 14 ISO1 CAN H 16 ISO2 RS485 GND 18 ISO2 RS485 1A 20 ISO2 RS485 1B 22 ISO2 RS485 GND 24 ISO2 RS485 2A 26 ISO2 RS485 2B
13
5
7
9 11 13 15 17 19 21 23 25
2
4
6
8 10 12 14 16 18 20 22 24 26
Top Row
1 GND 3 010VDC analog input 1 5 010VDC analog input 2 7 GND 9 420mA input 1 11 420mA input 2 13 GND 15 Relay 1 NO 17 Relay 1 COM 19 Relay 1 NC 21 Relay 2 NO 23 Relay 2 COM 25 Relay 2 NC
15
975-0806-01-01
Overview
Conext Gateway Conext Gateway Owner's Guide
Types of Conext Gateway Networks
The Conext Gateway can interface with different LAN devices using wired or wireless connections, so you can configure your Xanbus devices and monitor your power system performance.
n Conext Gateway on Xanbus (two separate networks can be supported)
n Conext Gateway on Modbus (via the 26-pin connector)
n Conext Gateway on Local Area Network (LAN, via Ethernet or Wi-Fi) When the Conext Gateway is part of a LAN, you can access the Conext Gateway web user interface from a computer on the same LAN via a wireless or wired LAN connection.
An Ethernet connection is required between the Conext Gateway and a router and computer for configuring the Conext Gateway.
Power Sources for the Conext Gateway
The Conext Gateway consumes an average of 2 W under most operating conditions and up to 10 W maximum. The power sources connected to the Conext Gateway must be capable of providing this power requirement.
There are three power sources for the Conext Gateway:
n AC/DC power adapter (supplied)
n Xanbus-enabled device via CAT5 or CAT5e cable (Xanbus cable)
n 924 V DC power input connections on the 26-pin connector
All three sources can be used alone or simultaneously. Typically, the AC/DC power adapter (supplied) is used as a primary source with either a Xanbus connection or the 26pin connector as secondary sources. See "Physical Features" on page 13 for connection locations.
DANGER
HAZARD OF ELECTRIC SHOCK AND FIRE Connect only to Safety Extra Low Voltage (SELV) circuits and power sources.
Failure to follow these instructions will result in death or serious injury.
Safety Extra Low Voltage (SELV) is a designation that refers to a circuit in which the voltages within the circuit and from the circuit to ground have values that are not a shock hazard, under both normal and single fault conditions.
975-0806-01-01
16
Conext Gateway Conext Gateway Owner's Guide
Overview
In the Conext Gateway, the SELV circuits and their intended connections are:
n The supplied AC/DC power adapter connected to the power port of the Conext Gateway.
n Xanbus communications and power which come from SELV circuits on Xanbusenabled Schneider products.
n 924 V DC power input connections which must be SELV and are connected to the Conext Gateway via the 26-pin connector.
n Ethernet circuits or Class 2 circuits (Class 2 is a 24V, 100VA limited circuit).
Conext Gateway Web User Interface
This section describes the elements of the web-based user interface for the Conext Gateway. This interface is used to check the status of the Conext Gateway, configure the communications options, monitor and log data for your network, and perform upgrades. The menu bar contains icons for going to the home screen or setup screen, linking to the Schneider Electric Web site, and closing or logging out of the web user interface.
Correct operation of the web user interface has been verified with the following browsers:
n Google ChromeTM 34.x or later
n Microsoft® Windows® Internet Explorer® 10.x or later
n Safari® 5.x or later
IMPORTANT: JavaScript and cookies must be enabled in your Web browser for the interface to function.
To access the web user interface, log in with a user name and password. For more details see Logging in to the Conext Gateway Web Application on page 34.
17
975-0806-01-01
Overview
Figure 5 Web user interface
Conext Gateway Conext Gateway Owner's Guide
1 Main menu bar displays major menu items including the Dashboard, Devices, Events, and Setup commands. It includes About, which shows Conext Gateway device information.
2 Sub-menu tabs displays sub-menu items expanding commands associated with the major menu items.
3 Main display area 4 Web app version and build number 5 Information bar displays the system date, time, and user type. Also, contains a link
to the Disclaimer page and Logout. 6 Floating Help tab
975-0806-01-01
18
Installation
Conext Gateway Conext Gateway Owner's Guide
2 Installation
What's in This Chapter?
Choosing a Location
21
Materials and Tools Required
22
Mounting the Conext Gateway
23
Wall Mount
23
DIN Rail Mount
23
Connecting the Conext Gateway to the Xanbus Network
24
Connecting the Conext Gateway to the Internet
26
Turning On the Conext Gateway
28
Turning Off the Conext Gateway
29
Power Cycling
29
Conext Gateway Conext Gateway Owner's Guide
Choosing a Location
Figure 6 Location choices
Installation
50mm
50mm
n Choose a clean, dry, easily accessible location indoors. n If you mount the Conext Gateway on a wall, the recommended height is at eye-
level so that you can clearly see the LED indicators and have easy access to the data and communication ports. n All of the ports on the Conext Gateway are accessible from the sides of the device when mounted on a wall or DIN rail. Clearance of at least 2 inches (50 mm) around the device is needed to allow for the bending radius of cables that connect to the Conext Gateway. n You should not run cables through conduits that can be exposed to lightning strikes. The following are recommended maximum cable lengths in a Conext Gateway system:
l 131 feet (40 m) Total Xanbus network l 328 feet (100 m) Router to Conext Gateway l 164 feet (50 m) Modbus Master (RS 485) to Conext Gateway
21
975-0806-01-01
Installation
Conext Gateway Conext Gateway Owner's Guide
Materials and Tools Required
The following materials are supplied in the Conext Conext Gateway package: n One Conext Gateway unit n One Conext Gateway Quickstart Guide n One AC/DC power supply adapter n One 8 GB micro SD card n One CAT5e Ethernet cable (7-ft) n One 26-pin connector n One 75 mm DIN rail The following materials and tools are not supplied but are required to complete the installation: n CAT5e Ethernet cable(s) n Modbus network cables(s) n Wire stripper n Ferrules n Screwdriver set n Pliers n Diagonal cutter or heavy duty scissors
975-0806-01-01
22
Conext Gateway Conext Gateway Owner's Guide
Installation
Mounting the Conext Gateway
Wall Mount
To mount the Conext Gateway on a wall:
1. Choose the location for mounting the device. 2. Using the diagram in the Conext Gateway Quickstart Guide (part number: 975-0804-
01-01), mark the mounting holes on the wall with a pencil.
3. The holes must be at the same height and 4 7/16 inches (112 mm) apart.
4. Insert the two anchors and mounting screws supplied in the marked locations on the wall, leaving a space of about ¼ inch (6 mm) between the wall and screw head.
5. If you are mounting the Conext Gateway on concrete, the supplied anchors and mounting screws are not suitable. Use two mounting screws that are equivalent to #6 screws.
6. Place the Conext Gateway on the mounting screws, and confirm a snug fit before going to the next step.
7. Connect the wiring and cables.
DIN Rail Mount
To mount the Conext Gateway on the DIN Rail:
1. Use a standard 35-mm "top hat" DIN rail (EN50022). 2. You may choose to move the mounting clip to the side as shown.
3. Attach the device to the DIN rail. Hook the bottom catch of the clip onto the rail, pull up a little to retract the bottom catch and hook the top catch of the clip onto the rail.
4. Connect the wiring and cables. 23
975-0806-01-01
Installation
Conext Gateway Conext Gateway Owner's Guide
Connecting the Conext Gateway to the Xanbus Network
To connect the Conext Gateway to the Xanbus network:
1. Connect the Conext Gateway to the Xanbus network using daisy chain confguration.
a. Xanbus components can be arranged in any order. b. The left connectors are Xanbus 1 and the right connectors are Xanbus 2.
c. Do not connect two end devices together to form a closed loop configuration. 2. Use a network terminator at both ends of the network. See Figure 7 .
a. Both networks require two Xanbus terminations; Xanbus 1 and Xanbus 2, if the second network is used. Xanbus 2 does not need terminators if it is not used.
3. Do not interconnect two separate Xanbus networks, meaning, do not daisy chain one Xanbus network with another.
a. Use only one pair of Xanbus ports for the daisy chain. b. If you only have one Xanbus network use Xanbus 1.
c. If you have two separate Xanbus networks connect the second network to Xanbus 2.
d. Devices on the Xanbus 1 network will not communicate with devices on the Xanbus 2 network.
e. See Figure 7 for Xanbus 1 pair of ports - one top and one bottom.
NOTICE
EQUIPMENT DAMAGE
n Do not connect a Xanbus cable plug into the Ethernet port on the Conext Gateway.
n Connect only to Xanbus ports and use the network terminators to each end device in the daisy chain.
n Do not connect Xanbus 1 and Xanbus 2 together as the system will become unstable.
Failure to follow these instructions can result in equipment damage.
975-0806-01-01
24
Conext Gateway Conext Gateway Owner's Guide
Figure 7 Sample Xanbus network
Xanbus1 Xanbus2
2 3
1 5
6 4
6
NOTE: This Xanbus 1 network is for illustration purpose only.
Installation
Conext 1 Gateway
unit Conext XW 2 Pro MPPT 80 3 600 Conext AGS (automatic 4 generator start) Conext SCP (system 5 control panel) Network 6 terminators
25
975-0806-01-01
Installation
Conext Gateway Conext Gateway Owner's Guide
Connecting the Conext Gateway to the Internet
Before connecting a computer and router to the Conext Gateway, make sure it meets the following prerequisites.
n Microsoft® Windows® 7 or later n Mac OS® X 10.4.8. or later
n Google ChromeTM 34.x or later n Microsoft® Windows® Internet Explorer® 10.x or later n Safari® 5.x or later n JavaScript and cookies must be enabled in your web browser. n Router - the network router must be able to supply DHCP addresses automatically to
connected devices. If your network router does not support automatic DHCP, refer to your network router's user guide or contact your system administrator.
To connect the Conext Gateway to a Computer on an Ethernet Network:
NOTICE
EQUIPMENT DAMAGE n Do not connect an Ethernet cable from the Conext Gateway to the MODEM port on the
network router.
n Do not connect an Ethernet cable plug into a Xanbus port on the Conext Gateway.
Failure to follow these instructions can result in equipment damage.
1. Make sure the computer and network router are turned on and the Conext Gateway is not turned on. Make sure the network router selected has DHCP enabled.
2. Connect one end of an Ethernet cable to the computer's network port. 3. Connect the other end of the Ethernet cable to a vacant Ethernet/LAN port on the
network router. 4. Connect one end of the Ethernet cable (supplied) to the LAN port on the network
router. 5. At this stage, the network router should be on, but the LED showing port activity on
the router will not show any indication. 6. Connect the other end of the Ethernet cable to the Conext Gateway. 7. At this stage, the Ethernet cable should be the only cable plugged into the Conext
Gateway.
975-0806-01-01
26
Conext Gateway Conext Gateway Owner's Guide Figure 8 Ethernet connection (LAN)
1
2
MODEM
3
LAN
4
1 Router/modem 2 Laptop 3 Conext Gateway unit 4 Ethernet cables
Installation
27
975-0806-01-01
Installation
Conext Gateway Conext Gateway Owner's Guide
Turning On the Conext Gateway
Before turning on the Conext XW+, you must connect it to a power source.
Figure 9 Power connections and button
Xanbus [B]
[A]
[C] 26-pin connector
NOTE: In the 26-pin connector, pin 1 connects to a 9-24VDC source and pin 2 connects to GND Power input. See " 26-pin connector" on page 15. To turn on the Conext Gateway:
1. Select a power source to the Conext Gateway. You can choose either of the following: a. Plug the (A) AC/DC power adapter into the AC wall outlet b. Connect the Conext Gateway to the Xanbus network (B) using Ethernet cables c. Provide 924 VDC power via by connecting to a power input source via the 26pin connector (C)
2. Connect (A), (B), or (C)'s connector to Conext Gateway's Power port for (A), Xanbus port for (B), or terminal block for (C), respectively.
3. Connect (A)'s power plug to an AC wall outlet or (B)'s other Xanbus cable connector to a Xanbus port on a Xanbus device. Alternatively, connect (C)'s pins 1 & 2 to a DCpowered device.
4. Observe the LED indicators and wait for the Power LED to light up (solid). The Conext Gateway is now turned on.
5. Proceed to "Logging in to the Conext Gateway Web Application" on page 34.
975-0806-01-01
28
Conext Gateway Conext Gateway Owner's Guide
Installation
WARNING
PHYSICAL INJURY HAZARD
Xanbus is a valid power source for the Conext Gateway. However, for the first time set-up, using Xanbus as a power source is not recommended. the Conext Gateway clock will override the other Xanbus devices' clocks and could trigger unintentional time-based events. Therefore, DO NOT connect the Conext Gateway to the Xanbus network prior to setting up the internal clock of the Conext Gateway. Refer to "Time Setup" on page 38 for instructions. If Xanbus is the only source powering the Conext Gateway, after installation verify the time settings in all devices.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Turning Off the Conext Gateway
To turn off the Conext Gateway: n Press the Power button according to the settings in Table 1 on page 14 or use the web
user interface to shut down the unit and turn it off.
Figure 10 Power button
Power Cycling
To power cycle the Conext Gateway:
1. Turn the Conext Gateway OFF. a. Press and hold the Power button according to the settings in Table 1 on page 14 or use the web user interface. b. Remove the power connections to the Conext Gateway.
2. Wait ten seconds before the next step. 3. Ensure that there is no USB thumb drive inserted in the USB Host port. 4. Turn the Conext Gateway ON.
a. Plug and connect the Conext Gateway to a power source.
29
975-0806-01-01
Configuration
Conext Gateway Conext Gateway Owner's Guide
3 Configuration
What's in This Chapter?
Using the Conext Gateway Web App via Wi-Fi Access Point (AP)
31
Web Security
32
Configuring the Conext Gateway
32
Logging in to the Conext Gateway Web Application
34
Changing the Password
35
Changing Conext Gateway Settings
37
Plant Setup
38
Time Setup
38
Import and Export Settings
39
Units
40
Modbus Settings
40
Restarting the Conext Gateway
41
Install Package
42
Changing Device Settings
43
Upgrading Firmware
45
Installing Conext Gateway Upgrades From a USB Drive
45
Installing Conext Gateway Upgrades Remotely
46
Upgrading Other Device Firmware
46
Conext Gateway Conext Gateway Owner's Guide
Configuration
Using the Conext Gateway Web App via Wi-Fi Access Point (AP)
NOTE: This procedure is not about connecting to a local area network (LAN) via Wi-Fi. In order to establish a user interface with Conext Gateway, a direct Wi-Fi connection is necessary. The following are the pre-requisites:
n Laptop with Microsoft® Windows® 7 or later, Mac OS® X 10.4.8. or later n Wi-Fi setting for the laptop is enabled
n Web browser such as Google ChromeTM 34.x or later, Microsoft® Windows® Internet Explorer® 10.x or later, Safari® 5.x or later
n JavaScript and cookies must be enabled in your web browser. Figure 11 Wi-Fi connection requirements
1
2
1 Laptop 2 Conext Gateway unit.
Wi-Fi password label is on the back panel. To connect: 1. Make sure the laptop and Conext Gateway are turned on. 2. Enable Wi-Fi on the laptop, if not already.
31
975-0806-01-01
Configuration
Conext Gateway Conext Gateway Owner's Guide
3. Open Wi-Fi Settings, then look for and connect to the Conext Gateway SSID. For example, you may look for something similar to ConextGateway_fe808b below.
4. Enter the Password when prompted. NOTE: The password is printed on a label on the back panel of the Conext Gateway unit.
5. Proceed to Logging in to the Conext Gateway Web Application.
Web Security
When you access the Conext Gateway web user interface you may see a warning stating that the web page is not trusted or the web page is not secure. This occurs because the Conext Gateway security certificate is not installed on your computer's operating system. You can elect to proceed anyway, if you are on a private local area network. Alternatively, you may choose to download the web security certificate from the Conext Gateway and install it on your PC. See "Installing the Conext Gateway Security Certificate" on page 63 for instructions on how to do this using the Chrome web browser on Windows. Other browsers will have similar mechanisms for installing the certificate.
Configuring the Conext Gateway
To complete Conext Gateway setup, you must successfully complete the procedures in Installation on page 20. Make sure the Conext Gateway is connected, the Power LED is on, and the Event LED is off. Your Xanbus devices should still be in standby mode.
When you initially log in to the web user interface, most of the setup information appears automatically with their default values. Some information must be changed (such as passwords), some information can be modified as needed, and some information can only be modified by a qualified IT professional.
The following items are part of the Conext Gateway configuration process:
Primary
1. Log in - see "Logging in to the Conext Gateway Web Application" on page 34 2. Change the password - see "Changing the Password" on page 35
975-0806-01-01
32
Conext Gateway Conext Gateway Owner's Guide
3. Set plant site information - see "Plant Setup" on page 38 4. Set the system time - see "Time Setup" on page 38
Configuration
Optional/Occasional 1. Configure general device settings - see "Changing Device Settings" on page 43 2. Upgrade the device firmware - see "Upgrading Firmware" on page 45
33
975-0806-01-01
Configuration
Conext Gateway Conext Gateway Owner's Guide
Logging in to the Conext Gateway Web Application
1. If you have connected the Conext Gateway via Wi-Fi, go to the IP address https://191.168.100.1 to access the web user interface.
2. If you have connected the Conext Gateway via Ethernet use the following steps: a. Insert a blank USB drive into the Conext Gateway USB port. Ensure there are no firmware upgrade files on this USB drive. b. After the Conext Gateway beeps twice, remove the USB drive. c. Insert the USB drive into your laptop USB port. d. Copy the HTML file to your laptop. e. Remove the USB drive from your laptop. f. Open the HTML file and click the link to the IP address of the Conext Gateway.
3. Bookmark this address. IMPORTANT: The web address is a locally and privately assigned (LAN) device address that is also protected by a firewall.
4. Select your User Name. Select Admin. 5. Enter your Password. Initial password is Admin123. 6. When prompted, change the initial password immediately to protect the device from
unauthorized users and to enable changes to device settings. This is an important step to follow.
NOTE: To perform adminstrative functions such as a firmware update, set User Name to Admin. Settings are disabled until the initial password is changed.
975-0806-01-01
34
Conext Gateway Conext Gateway Owner's Guide
Configuration
6. Change the Conext Gateway SSID and network password.
a. Go to Setup > Network > Wifi Access Point Settings
b. (Optional) Replace the current Wi-Fi network name under the SSID field with an appropriate name. You are limited to 64 alphanumeric characters including symbols.
c. Replace the current password under the Password field with 10 or more alphanumeric characters including symbols.
d. Click Apply to save the new password and/or SSID.
Changing the Password
What to expect when logging in for the first time:
n When logging in to the web application for the first time, either as Admin or User or Guest, the system will automatically ask you to change the password from the factory default Admin123 or User123 or Guest123, respectively.
Figure 12 Message box to change password
n Click OK and follow the instructions to change the password.
35
975-0806-01-01
Configuration
Figure 13 Password screen
Conext Gateway Conext Gateway Owner's Guide
n You may have to log in again after changing the initial password.
975-0806-01-01
36
Conext Gateway Conext Gateway Owner's Guide
To change the password after the initial log in: Figure 14 Change password setting
Configuration
1. Click Setup > Manage Passwords > Change Passwords. 2. Select the User name type. Note: Admin-level can change all passwords. User-level
can change User and Guest passwords. Guest-level cannot change any passwords. l Admin l User l Guest
3. Enter the Old password. 4. Enter the New password. 5. Enter the Confirm password. 6. Click Apply. Your settings will be immediately applied.
Changing Conext Gateway Settings
The procedures for configuring the other Conext Gateway Settings are described in the following sections. To change Conext Gateway settings:
1. In the main menu bar, click Setup > Configuration. The Configuration settings appear in the main display area.
2. Click any of the following settings. a. Plant setup - see Plant Setup on page 38 b. Time setup - see Time Setup on page 38 c. Import & export settings - see Import and Export Settings on page 39 d. Units - see Units on page 40 e. Modbus settings - see Modbus Settings on page 40 f. Restart Conext Gateway - see Restarting the Conext Gateway on page 41 g. Install package - see Install Package on page 42
37
975-0806-01-01
Configuration
Plant Setup
Conext Gateway Conext Gateway Owner's Guide
3. With only a few exceptions, you may save a setting by clicking Apply or ignore changes by clicking Cancel. That portion of the window expands to display the change options for that setting. The size and content of the expanded window varies depending on the setting type.
It is recommended to name the plant site to distinguish it from other installations in your power system. Figure 15 Plant setup screen
Time Setup
To enter plant information: 1. Click Setup > Configuration> Plant setup. 2. Enter a Friendly name. Choose a name that can easily identify the plant site to your
customers. 3. Enter the Installed AC capacity (kW). 4. Enter the Installed year. 5. Click Apply. Your settings will be immediately applied.
You can set the time zone plus date and time in the Time setup menu. Figure 16 Time setup screen
975-0806-01-01
38
Conext Gateway Conext Gateway Owner's Guide
Configuration
To change the Conext Gateway time:
1. Click Setup > Configuration> Time setup. 2. Select the Time zone. This time setting overrides settings on other devices in the
system. 3. Enter the date and time by clicking the calendar icon beside Date & time. 4. Click Apply. Your settings will be immediately applied.
Import and Export Settings
This command setting allows you to either export the configuration of this Conext Gateway to another Conext Gateway unit or import the configuration of another Conext Gateway to supersede this Conext Gateway unit.
Figure 17 Import & export setup screen
To export settings:
1. In the main menu bar, click Setup > Configuration. The Configuration settings appear in the main display area.
2. Click Import & export settings. a. Click Download. The compressed configuration file usersettings.zip will be automatically saved to the Downloads folder of the browser. b. If necessary, you may copy this file to an external drive and later import it to a different Conext Gateway device.
To import settings:
1. In the main menu bar, click Setup > Configuration. The Configuration settings appear in the main display area.
2. Click Import & export settings.
a. Click Upload. b. Locate the compressed configuration file usersettings.zip from a local
directory or an external drive.
c. Click Restart now to finish the importing of the configuration file.
39
975-0806-01-01
Configuration
Units
Conext Gateway Conext Gateway Owner's Guide
This setting allows you to change the standard unit of measurement used in solar irradiance, temperature, and wind speed. Figure 18 Units setup screen
Modbus Settings
To change units: 1. In the main menu bar, click Setup > Configuration.
The Configuration settings appear in the main display area. 2. Click Unit.
Currently, only Temperature can be changed to either celsius or farenheit. 3. Save the settings by clicking Apply .
Alternatively, ignore the changes by clicking Cancel.
This setting allows you to change the Modbus serial port communication settings. Figure 19 Modbus settings screen
975-0806-01-01
40
Conext Gateway Conext Gateway Owner's Guide
Configuration
To change Modbus settings:
1. In the main menu bar, click Setup > Configuration. The Configuration settings appear in the main display area.
2. Click Modbus settings. a. Select the proper Baud rate. b. Select the correct Parity. c. Select the corresponding Stop bits.
3. Save the settings by clicking Apply . Alternatively, ignore the changes by clicking Cancel.
Restarting the Conext Gateway
You are allowed to to restart, reset the configuration, or return the Conext Gateway to all of the original factory settings remotely from the web user interface or by pressing and holding the Power button according to the settings in Table 1 on page 14.
Figure 20 Restart Conext Gateway screen
Choose what to do in the web user interface:
1. Click Setup > Configuration > Restart Conext Gateway. 2. Click any of the action buttons depending on the kind of reset you want to perform.
l Restart Conext Gateway will execute a soft restart of the Conext Gateway unit. Doing so will temporarily disconnect and put all connected Xanbus devices on Standby.
l Reset configuration will execute a reset of Conext Gateway settings, including passwords, network configuration, and plant setup. This action does not affect the configuration of connected devices.
l Reset to factory settings will execute a complete return to factory settings
41
975-0806-01-01
Configuration
Install Package
Conext Gateway Conext Gateway Owner's Guide
including forgetting all detected devices, removing data logs, removing event logs, and resetting all configuration. 3. Follow the succeeding instructions.
To install a Conext Gateway upgrade remotely: 1. From the Conext Gateway Web Application home page, go to Setup >
Configuration > Install Package.
2. Download the firmware package.
a. Click Get package. This will take you to the Conext Gateway product webpage.
b. From the product webpage, go to DOWNLOADS > Firmware.
c. Search for the latest firmware package from the list and click it to begin downloading.
d. Save the .epkg file to a local directory.
3. Go back to the Conext Gateway Web Application.
4. Click Upload package .
5. Search and select the firmware package (.epkg file) you saved in a local directory from the Conext Gateway product webpage.
6. Click Open from the Windows dialog. The upgrade begins automatically.
7. As the firmware package is transferred to the Conext Gateway, progress is indicated in percentage, and a message screen indicates when the file transfer has been completed successfully.
8. When prompted, reboot the Conext Gateway. See Restarting the Conext Gateway on page 41.
975-0806-01-01
42
Conext Gateway Conext Gateway Owner's Guide
Configuration
Changing Device Settings
Before making any changes, familiarize yourself thoroughly with the effects of changing the settings of another device.
NOTICE
RISK OF EQUIPMENT DAMAGE n Consult the device's Owner's Guide when changing the device's settings. n Make sure the device connected on the Xanbus or Modbus network is in Standby
mode before changing settings. n Do not change any settings unless you are familiar with the device. Failure to follow these instructions can result in equipment damage.
Figure 21 Sample Device Overview screen - Icons display
43
975-0806-01-01
Configuration
Conext Gateway Conext Gateway Owner's Guide Figure 22 Sample Device Overview screen - List display
To change a device setting: 1. In the main menu bar, click Devices. See Figure 21 for a sample of the default display
of all connected devices. 2. If you want a shorter list of devices, switch to a List display. See Figure 22. 3. Put the device in to Standby mode first.
a. Click a device you want to put in to Standby mode. b. Click Configuration > Controls.
Note that Controls may be called differently such as AGS Control. c. Search for the control setting Operating Mode. d. Select Standby. e. Click Apply.
4. Click Configuration 5. Choose either Basic or Advanced settings. 6. Click a device setting category. For example, Inverter Settings in the case of an
inverter device. 7. Change a specific setting by selecting from a drop down list, toggling a switch, or
entering a different value. 8. Click Apply to save the changes. 9. Use the Operating Mode menu to put the device back into normal operating mode.
975-0806-01-01
44
Conext Gateway Conext Gateway Owner's Guide
Configuration
Upgrading Firmware
You can perform firmware upgrades for your Conext Gateway and Xanbus-enabled devices when they are available for download.
There are three upgrade procedures, namely:
n "Installing Conext Gateway Upgrades From a USB Drive" below n "Installing Conext Gateway Upgrades Remotely" on the facing page n "Upgrading Other Device Firmware" on the facing page
Installing Conext Gateway Upgrades From a USB Drive
Follow the procedure below to change the Conext Gateway firmware to an updated version.
To update the firmware:
1. Using a laptop computer, format a USB drive and open a web browser. 2. Go to http://solar.schneider-electric.com and download the latest Conext Gateway
firmware version (contained in a ZIP file).
3. Navigate to Products > Battery Based Inverters > Accessories > Conext Gateway
4. Click DOWNLOADS > Firmware > FWYYYYMMDD-Gateway VX.XX BNXXXX (865-0326).ZIP
5. Pick the firmware version (V) with a higher number and also a higher build number (BN). The ZIP file is approximately 35 MB.
6. Extract the .epkg file from the ZIP file into the root directory of the USB drive (supplied with the unit).
7. To initiate the update to the firmware:
a. Insert the USB drive into the port on the Conext Gateway.
b. The Conext Gateway will beep once and the LED will blink while the the firmware is copied to the Conext Gateway and the upgrade is performed. This can take 510 minutes.
c. If the update takes more than 10 minutes, make sure that the .epkg file is copied correctly into the root directory.
Important: Once the USB drive is inserted, Do not turn off the Conext Gateway. 8. Once the firmware upgrade is done, the Conext Gateway emits two beeps. and the
LED indicator stops blinking.
9. Remove the USB drive.
10. Manually reboot the Conext Gateway using the power switch to complete the firmware upgrade process.
45
975-0806-01-01
Configuration
Conext Gateway Conext Gateway Owner's Guide
Installing Conext Gateway Upgrades Remotely
For full instructions, see "Install Package" on page 42.
Upgrading Other Device Firmware
It is possible to upgrade a device's firmware through the Conext Gateway web application.
NOTICE
RISK OF EQUIPMENT DAMAGE n Consult the device's Owner's Guide when changing the device's settings. n Make sure the device connected on the Xanbus or Modbus network is in Standby
mode before changing settings. n Do not change any settings unless you are familiar with the device. Failure to follow these instructions can result in equipment damage.
Figure 23 Sample Device Overview screen - List display
975-0806-01-01
To obtain the firmware package: 1. From a laptop computer, open a web browser. 2. Go to http://solar.schneider-electric.com and download the latest Conext Gateway
firmware version (contained in a ZIP file). 3. Navigate to Products > Battery Based Inverters > Accessories. 4. Click DOWNLOADS > Firmware >FWYYYYMMDD-Product NameVX.XX
BNXXXX (Product Number).ZIP. 5. Pick the firmware version (V) with a higher number and also a higher build number
(BN). The ZIP file is approximately 6 MB. 6. Extract the .xf0 file from the ZIP file into a folder on the local drive. To upgrade a device firmware: 1. In the main menu bar, click Devices. 2. Put the device in to Standby mode first.
a. Click a device you want to put in to Standby mode. b. Click Configuration > Controls.
Note that Controls may be called differently such as AGS Control.
46
Conext Gateway Conext Gateway Owner's Guide
Configuration
c. Search for the control setting Operating Mode. d. Select Standby. e. Click Apply. 3. Click Firmware . 4. Click Upgrade. 5. Follow the step-by-step upgrade instructions. 6. To upgrade all similar devices in the network, click Upgrade All. 7. Follow the step-by-step upgrade instructions. 8. Use the Operating Mode menu to put the device back into normal operating mode.
47
975-0806-01-01
Monitoring
Conext Gateway Conext Gateway Owner's Guide
4 Monitoring
What's in This Chapter?
Monitoring LED Indicators
49
Startup
49
Monitoring the Power Plant
49
Conext Gateway Conext Gateway Owner's Guide
Monitoring
Monitoring LED Indicators
LED indicators allow you to monitor the functioning of the Conext Gateway.
Table 2 LED indicators
Icon Color LED
Description
The Conext Gateway is powered and ready Green Power
to communicate when on.
Device is logging data to internal memory Green Memory
when flashing.
C
Device is actively transferring data with a
Green Cloud
communication device/s.
X
Device is actively transferring data with a
Green Xanbus
Xanbus device/s.
M
Device is actively transferring data with a
Green Modbus
Modbus device/s.
! Red
Event
Devices on the Power system have events or alerts when on.
Blue Wi-Fi Wi-Fi connectivity is established.
Startup
The Power LED flashes slowly when the Conext Gateway application is loading and flashes quickly during application initialization. The other LEDs illuminate as startup progresses. Once the Conext Gateway is ready, the Power LED turns on (solid). This process takes about two minutes.
Monitoring the Power Plant
You can view the current state of the power plant by viewing the Conext Gateway dashboard.
With the Dashboard, you can view power flow between the connected devices, battery information, and energy production and consumption.
49
975-0806-01-01
Monitoring
Figure 24 Dashboard
Conext Gateway Conext Gateway Owner's Guide
Power flow tab shows an interactive and graphical view of the power plant with its 1
different connected devices. Battery summary tab shows a historical line graph of four battery metrics such as 2 current, volts, temperature, and state-of-charge (SOC). It shows one battery at a time. Battery comparison tab shows a historical and comparative line graph of the four 3 battery metrics against all the different batteries. Energy tab shows a chronological summary of energy that is produced by three 4 sources; solar, grid, and battery. Also shows a chronological summary of energy that is output to four energy consumers; load, grid, battery, and generator. Energy comparison tab shows a comparative graph between energy input and 5 output. Main display board shows the different graphical elements of the power plant, the 6 devices, battery, and energy information.
To view the dashboard:
1. After successfully logging in, the very first view to show on the main display board is the Dashboard - Power Flow.
2. Click each of the tabs on the left to switch to different views.
975-0806-01-01
50
Troubleshooting
Conext Gateway Conext Gateway Owner's Guide
5 Troubleshooting
What's in This Chapter?
Events
53
Conext Gateway Conext Gateway Owner's Guide
Troubleshooting
Events
The events detected and monitored by Conext Gateway vary in type. The types of events are categorized into warnings and detected faults. Warnings are displayed as orange icons with an exclamation point. Detected faults are displayed as red icons with an exclamation point.
When devices detect an event that usually resolves by itself, it is still reported to Conext Gateway and logged. It is logged under Historical(see Figure 26 However, events that happen repeatedly escalate to a fault or sometimes the device detects a fault, such as a ground fault. When a fault is detected, it is also reported to Conext Gateway and logged. If service intervention is required, it is logged under Active (see Figure 25 ). It remains there until service is performed. Also, if user intervention is required, such as remotely resetting a device, the event is logged under Active and remains there until the user is able to perform the necessary action.
53
975-0806-01-01
Troubleshooting
Figure 25 Active events
Conext Gateway Conext Gateway Owner's Guide
Figure 26 Historical events
975-0806-01-01
54
Conext Gateway Conext Gateway Owner's Guide
Troubleshooting
To view Events:
1. In the main menu bar, click Events. The Active events are displayed first in the main display board.
2. Click Historical to view events that have been logged and/or resolved. 3. To download a copy of the events, click the CSV icon on the lower right hand corner
of the main display board.
55
975-0806-01-01
Specifications
Conext Gateway Conext Gateway Owner's Guide
6 Specifications
What's in This Chapter?
Electrical Specifications
57
Physical Specifications
57
Features
58
Regulatory
58
FCC Regulatory Compliance
58
ISED Regulatory Compliance
59
Simplified EU Declaration of Conformity
60
Schneider Electric Products that Work with the Conext Gateway
60
Dimensions
61
Conext Gateway Conext Gateway Owner's Guide
Specifications
Electrical Specifications
NOTE: Specifications subject to change without prior notice.
NOTICE
EQUIPMENT DAMAGE Do not power the unit without first installing the supplied antennas. Failure to follow these instructions can result in equipment damage.
Power Consumption AC/DC adapter (supplied)
Xanbus 924V on 26-pin connector Operation Frequency Max. radio frequency power transmitted
2 W average / 10 W peak
Input: 100-240 V AC, 50-60 Hz, 0.48 A, Output: 12 V DC, 1.6 A, 5.5 mm outer, 2.1 mm centerpositive jack.
NOTE: Required when used with the Conext SW. When connected to Conext XW Pro/XW+ or MPPT 80 600 providing network power
924 V DC, 1 A max input only through pins 1 and 2 Accepts 1624 AWG pin wire size.
24122472 MHz (Europe) 24142462 MHz (N. America)
17.06 dBm (E.I.R.P., Declaration for EU)
Physical Specifications
NOTE: Specifications subject to change without prior notice.
Weight (device only) Dimensions (device only) (W × H × D) Shipping package dimensions Shipping package weight Housing/Mounting system IP rating / Mounting Location Status Display Temperature
Humidity
337 g (0.74 lb) 137 x 131 x 41 mm (5.4 × 5.2 × 1.6 inches)
158 × 158 × 188 mm (6.2 × 6.2 × 7.4 inches) 920 g (2 lbs) ABS Plastic / 35-mm DIN rail clip IP 20, NEMA 1, Indoor only 7 x LEDs Operating: -4 to 122 °F (-20 to 50 °C) Storage: -40 to 185 °F (-40 to 85 °C) Maximum case temperature: 140 °F (60 °C) Operating: < 95%, non-condensing Storage: < 95%
57
975-0806-01-01
Specifications
Conext Gateway Conext Gateway Owner's Guide
Features
NOTE: Specifications subject to change without prior notice.
Programmable dry contact relay
Web-base user interface Remote firmware upgrades
Custom Data logger Micro-SD card (supplied)
Screw 3-terminal, 16-24 AWG, NC-Com-NO, Form: Class 2, 24 V DC, 4 A max SELV input only Internet Browser Yes (Conext Gateway and connected Xanbus devices) Yes (requires Micro-SD card) 8GB
Regulatory
NOTE: Specifications subject to change without prior notice.
EMC immunity EMC emissions Substances / environmental
EN61000-6-1 EN 301 489-1, -17 EN61000-6-3 EN 301 489-1, -17 FCC part 15B RoHS
EN 55035 EN 55032 ICES-003
FCC ID
Contains 2AODL-CONEXTGTWY
IC ID
Contains 24209-CONEXTGTWY
Model number
865-0329
FCC Regulatory Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
n Reorient or relocate the receiving antenna.
n Increase the separation between the equipment and receiver.
975-0806-01-01
58
Conext Gateway Conext Gateway Owner's Guide
Specifications
n Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
n Consult the dealer or an experienced radio/TV technician for help.
Note: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
RF Exposure Compliance
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Supplier's Declaration of Conformity
47 CFR § 2.1077 Compliance Information Unique Identifier: Trade Name: Conext Gateway Model No.: 865-0329
Responsible Party U.S. Contact Information Schneider Electric Solar Inverters USA, Inc. 250 S. Vasco Road, Livermore, CA 94551 https://solar.schneider-electric.com/
FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
ISED Regulatory Compliance
This device contains licence-exempt transmitter(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s).
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.
L'émetteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
1. L'appareil ne doit pas produire de brouillage;
2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
59
975-0806-01-01
Specifications
Conext Gateway Conext Gateway Owner's Guide
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. Cet équipement est conforme aux limites d'exposition aux radiations IC CNR-102 établies pour un environnement non contrôlé. Cet émetteur ne doit pas être situé ou fonctionner conjointement avec une autre antenne ou un autre émetteur. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps. CAN ICES-3 (B)/NMB-3(B)
Simplified EU Declaration of Conformity
Hereby, Schneider Electric declares that the radio equipment type 865-0329 is in compliance with Directive 2014/53/EU.The full text of the EU declaration of conformity is available at the following internet address: https://solar.schneider-electric.com/
Schneider Electric Products that Work with the Conext Gateway
n Conext XWPro Inverter / Charger: l Conext XWPro 6848 NA Product No. 865-6848-21
n Conext XW+ Inverter / Chargers: l Conext XW+ 7048 E Product No. 865-7048-61 l Conext XW+ 8548 E Product No. 865-8548-61 l Conext XW+ 5548 NA Product No. 865-5548-01 l Conext XW+ 6848 NA Product No. 865-6848-01
n Conext SW Inverter / Chargers: l SW 2524 120/240 Product No. 865-2524 l SW 4024 120/240 Product No. 865-4024 l SW 2524 230/240 Product No. 865-2524-61 l SW 4024 230/240 Product No. 865-4024-61
n Conext MPPT 60 150 Solar Charge Controller: Product No. 865-1030-1 n Conext MPPT 80 600 Solar Charge Controller: Product No. 865-1032 n Conext System Control Panel (SCP): Product No. 865-1050-01 n Conext Automatic Generator Start (AGS): Product No. 865-1060-01 n Conext Battery Monitor: Product No. 865-1080-01
975-0806-01-01
60
Conext Gateway Conext Gateway Owner's Guide
Dimensions
NOTE: Specifications subject to change without prior notice.
Specifications
61
975-0806-01-01
Using Chrome to Install the Conext GatewaySecurity Certificate
Conext Gateway Conext Gateway Owner's Guide
A Using Chrome to Install the Conext GatewaySecurity Certificate
What's in This Chapter?
Installing the Conext Gateway Security Certificate
63
Conext Gateway Conext Gateway Owner's Guide
Using Chrome to Install the Conext GatewaySecurity Certificate
Installing the Conext Gateway Security Certificate
These instructions explain how to download the web security certificate from the Conext Gateway and install it on your PC using Chrome on Windows 10. To export the security certificate:
1. Open the Chrome developer tools using one of the following methods: a. Press F12. b. Click the three dots in the top right-hand corner of the window, then click More Tools and then Developer Tools. c. Use the keyboard command Ctrl+Shift+I.
2. Navigate to the Security tab in Developer Tools. 3. Click View Certificate.
Figure 27 Security tab
63
975-0806-01-01
Using Chrome to Install the Conext GatewaySecurity Certificate
Conext Gateway Conext Gateway Owner's Guide
4. Click the Certification Path tab. Figure 28 Certificate path tab
5. Click View Certificate.
975-0806-01-01
64
Conext Gateway Conext Gateway Owner's Guide
Using Chrome to Install the Conext GatewaySecurity Certificate
6. Confirm that the hex string following the underscore in the Issued By: statement matches the MAC Address of your Conext Gateway.
Figure 29 View certificate
65
975-0806-01-01
Using Chrome to Install the Conext GatewaySecurity Certificate
7. Click the Details tab. Figure 30 Details tab
Conext Gateway Conext Gateway Owner's Guide
975-0806-01-01
66
Conext Gateway Conext Gateway Owner's Guide
Using Chrome to Install the Conext GatewaySecurity Certificate
8. Click Copy to File...to open the Certificate Export Wizard and then click Next. Figure 31 Certificate Export Wizard
67
975-0806-01-01
Using Chrome to Install the Conext GatewaySecurity Certificate
Conext Gateway Conext Gateway Owner's Guide
9. Click the radio button beside DER encoded binary and then click Next. Figure 32 Export settings
975-0806-01-01
68
Conext Gateway Conext Gateway Owner's Guide
Using Chrome to Install the Conext GatewaySecurity Certificate
10. Click Finish to save it to your file system (remember where it has saved). Figure 33 Confirmation
69
975-0806-01-01
Using Chrome to Install the Conext GatewaySecurity Certificate
Conext Gateway Conext Gateway Owner's Guide
To import the security certificate:
1. Using the windows file browser, go to the location where you saved the certificate file, and double-click the certificate file.
2. Click Install Certificate and then click Next. Figure 34 Certificate Import Wizard
975-0806-01-01
70
Conext Gateway Conext Gateway Owner's Guide
Using Chrome to Install the Conext GatewaySecurity Certificate
3. Click the radio button beside Place all certificates in the following store and then click Browse.
Figure 35 Import settings
71
975-0806-01-01
Using Chrome to Install the Conext GatewaySecurity Certificate
Conext Gateway Conext Gateway Owner's Guide
4. Click Trusted Root Certificate Authorities and then click OK. Figure 36 Select certificate store
975-0806-01-01
72
Conext Gateway Conext Gateway Owner's Guide
Using Chrome to Install the Conext GatewaySecurity Certificate
The Certificate Import Wizard should look like this: Figure 37 Import settings confirmation
5. Click Next and then click Finish. 6. Click Yes to the security warning, and then click OK when the Certificate Import
Wizard confirms the import was successful.
7. Restart your browser and confirm the word Secure is now beside the Conext Gateway web user interface address.
Figure 38 Website secure
73
975-0806-01-01
Schneider Electric
As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this publication. For other country details please contact your local Schneider Electric Sales Representative or visit the Schneider Electric Solar Business website at: http://solar.schneider-electric.com/ © 2019 Schneider Electric. All Rights Reserved.
975-0806-01-01
Printed in: