SZ23120301S04 BLU C5L MAX FCC HAC T-Coil Report

HAC T-Coil Report

BLU Products, Inc. BLUC5LMX177 Smart Phone YHLBLUC5LMX177 YHLBLUC5LMX177 bluc5lmx177

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7259254
REPORT No.SZ23120301S04

Hearing Aid Compatibility (HAC) T-Coil Test Report

APPLICANT

: BLU Products, Inc.

PRODUCT NAME : Smart Phone

MODEL NAME

: C5L MAX

BRAND NAME

: BLU

FCC ID STANDARD(S)
RECEIPT DATE

: YHLBLUC5LMX177
: FCC 47 CFR Part 20(20.19) ANSI C63.19-2019
: 2023-12-26

TEST DATE

: 2024-02-19 to 2024-03-22

ISSUE DATE

: 2024-04-17

Edited by:

Xie Yiyun (Rapporteur)

Approved by: Gan Yueming (Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 1 of 28

REPORT No.SZ23120301S04

DIRECTORY
1. Statement of T-Coil Measurement4 2. Technical Information 5 2.1. Applicant and Manufacturer Information 5 2.2. Equipment under Test (EUT) Description5 2.3. Photographs of the EUT 7 2.4. Applied Reference Documents 7 3. Air Interface and Operating Mode 8 4. T-Coil Test Requirements and Restrictions 9 4.1. T-Coil Coupling Qualifying Field Strengths 9 4.2. Desired ABM signal and Undesired ABM Field Qualification Requirements 9 4.3. Frequency Response 10 5. HAC (T-Coil) Measurement System11 5.1. T-Coil Measurement Setup 11 5.2. Base Station Gain Factor12 5.3. T-Coil Measurement Reference Plane13 5.4. System Validation 14 6. T-Coil Test Procedure15 6.1. General Description 15 6.2. T-Coil Test Flow17 7. Test Equipment List 19 8. Summary Test Results20 8.1. Test Guidance 20 8.2. Test Results 21 9. Uncertainty Assessment 26

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 2 of 28

REPORT No.SZ23120301S04
Annex A General Information27 Annex B Test Setup Photos 28 Annex C Plots of T-Coil Test Results28 Annex D DASY Calibration Certificate28

Version 1.0

Date 2024-04-17

Change History

Reason for change First edition

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 3 of 28

REPORT No.SZ23120301S04
1. Statement of T-Coil Measurement

The lowest contiguous point count of primary group and secondary group found during test as bellows:

Air Interface

Primary Group Contiguous Point Count

Secondary Group Contiguous Point Count

Frequency Response

GSM CMRS Voice

193

235

PASS

UMTS CMRS Voice

228

344

PASS

VoLTE

241

433

PASS

VoWiFi

250

397

PASS

Note:

1. This device is in compliance with compliance with T-Coil requirement specified in FCC 47 CFR Part

20.19 and tested in accordance with the measurement methods and procedures specified in ANSI

C63.19-2019 and FCC KDB publications.

2. The 2N force is used for testing requirements related to use by persons with hearing devices and the 8N

force is used for testing requirements related to use by persons without hearing devices.

3. When the test result is a critical value, we will use the measurement uncertainty give the judgment result

based on the 95% confidence intervals.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 4 of 28

2. Technical Information

REPORT No.SZ23120301S04

Note: Provide by applicant.
2.1. Applicant and Manufacturer Information

Applicant: Applicant Address: Manufacturer: Manufacturer Address:

BLU Products, Inc. 8600 NW 36th Street, Suite #300 Miami, FL 33166, USA BLU Products, Inc. 8600 NW 36th Street, Suite #300 Miami, FL 33166, USA

2.2. Equipment under Test (EUT) Description

Product Name: EUT IMEI: Hardware Version: Software Version:
Frequency Bands:
Modulation Mode:

Smart Phone
864913043933067/78 864913043933182/78
YK507-MB-V1.0
BLU_C0176_V13.0.G.03.08_GENERIC_6-12-2023_1930
GSM 850: 824 MHz ~ 849 MHz GSM 1900: 1850 MHz ~ 1910 MHz WCDMA Band II: 1850 MHz ~ 1910 MHz WCDMA Band IV: 1710 MHz ~ 1755 MHz WCDMA Band V: 824 MHz ~ 849 MHz LTE Band 2: 1850 MHz ~ 1910 MHz LTE Band 4: 1710 MHz ~ 1755 MHz LTE Band 5: 824 MHz ~ 849 MHz LTE Band 12: 699 MHz ~ 716 MHz LTE Band 17: 704 MHz ~ 716 MHz LTE Band 25: 1850 MHz ~ 1915 MHz LTE Band 26: 814 MHz ~ 849 MHz LTE Band 41: 2496 MHz ~ 2690 MHz LTE Band 66: 1710 MHz ~ 1780 MHz LTE Band 71: 663 MHz ~ 698 MHz WLAN 2.4GHz: 2412 MHz ~ 2472 MHz WLAN 5.2GHz: 5180 MHz ~ 5240 MHz WLAN 5.3GHz: 5260 MHz ~ 5320 MHz WLAN 5.5GHz: 5500 MHz ~ 5720 MHz WLAN 5.8GHz: 5745 MHz ~ 5825 MHz Bluetooth: 2402 MHz ~ 2480 MHz GSM/GPRS: GMSK

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 5 of 28

REPORT No.SZ23120301S04

Antenna type: VoLTE Mode:

EDGE: 8PSK WCDMA: QPSK, 16QAM LTE: QPSK, 16QAM, 64QAM 802.11b: DSSS 802.11a/g/n-HT20/HT40/ac-VHT20/40/80: OFDM BR+EDR: GFSK(1Mbps), /4-DQPSK(2Mbps), 8-DPSK(3Mbps) Bluetooth LE: GFSK(1Mbps, 2Mbps) WWAN: PIFA Antenna WLAN: PIFA Antenna Bluetooth: PIFA Antenna
Support

VoWi-Fi Mode:

Support

SIM Cards Description:

SIM 1

GSM+WCDMA+LTE

SIM 2

GSM+WCDMA+LTE

For dual SIM card version, both the SIM 1 and SIM 2 are the same chipset unit and tested as a single chipset, the SIM 1 was selected for testing. Note: For more detailed description, please refer to specification or user manual supplied by the applicant

and/or manufacturer.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 6 of 28

2.3. Photographs of the EUT

REPORT No.SZ23120301S04

Please refer to the External Photos for the Photos of the EUT

2.4. Applied Reference Documents

Leading reference documents for testing:

Method

No.

Identity

Document Title

determination

Remark

1 FCC 47 CFR Part 20 (20.19) Hearing aid-compatible mobile handsets

No deviation

American National Standard Methods of

2 ANSI C63.19-2019

Measurement of Compatibility between Wireless Communications Devices and

No deviation

Hearing Aids

3 KDB 285076 D01v06r04

HAC Guidance

No deviation

4 KDB 285076 D02v04

T-Coil testing for CMRS IP

No deviation

5 KDB 285076 D03v01r06

HAC FAQ

No deviation

Note: Additions to, deviation, or exclusions from the method shall be judged in the "method

determination" column of add, deviate or exclude from the specific method shall be explained in the

"Remark" of the above table.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 7 of 28

REPORT No.SZ23120301S04
3. Air Interface and Operating Mode

Air Interface GSM

Band
GSM850 GSM1900

Transport Type
VO

Simultaneous Transmitter
WLAN,BT

Name of Voice Service
CMRS Voice

Power Reduction
No
No

Band II

WCDMA

Band IV

VO

(UMTS)

Band V

WLAN,BT

No

CMRS Voice

No

No

Band 2

No

Band 4

No

Band 5

No

Band 12

FDD-LTE

Band 17

&

VD

TDD-LTE

Band 25

Band 26

WLAN,BT

No No VoLTE No No

Band 41

No

Band 66

No

Band 71

No

2450

No

5200 (U-NII-1)

No

WiFi

5300 (U-NII-2A)

VD

GSM, UMTS, LTE

VoWiFi

No

5500 (U-NII-2C)

No

5800 (U-NII-3)

No

BT

2450

DT

GSM, UMTS, LTE

N/A

No

Note:

1) Air Interface/Band MHz: List of all air interfaces and bands supported by the handset.

2) Type: For each air interface, indicate the type of voice transport mode:

i. VO = legacy Cellular Voice Service, from ANSI C63.19-2019;

ii. DT = Digital Transport only (no voice); and

iii. VD = IP Voice Service over Digital Transport.

3) Simultaneous Transmitter: Indicate any air interface/bands that operate in simultaneous or concurrent

service transmission mode.

4) Name of Voice Service: See Q4 in 285076 D03 HAC FAQ for further clarification.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 8 of 28

REPORT No.SZ23120301S04
4. T-Coil Test Requirements and Restrictions
4.1. T-Coil Coupling Qualifying Field Strengths
In order to comply with the requirements for T-Coil use, a WD's tested operating modes shall simultaneously meet the requirements for minimum desired ABM signal level and maximum undesired ABM field contained in this sub clause at the minimum specified number of scanned locations. When measured as specified in this standard, there are two groups of qualifying measurement points:
Primary group: A qualifying measurement point shall have its T-Coil signal, desired ABM signal, -18 dB(A/m) at 1 kHz, in a 1/3 octave band filter. These measurements shall be made with the WD operating at a reference input level as specified in Table 6.1. Simultaneously, the qualifying measurement point shall have its weighted magnetic noise, undesired ABM field -38 dB (A/m).
Secondary group: A qualifying measurement point shall have its weighted magnetic noise, undesired ABM field -38 dB (A/m). This group inherently includes all the members of the primary group.
These levels are designed to be compatible with hearing aids that produce the same acoustic output level for either an acoustic input level of 65 dB SPL or a magnetic input level of -25 dB(A/m) (56.2 mA/m) at either 1.0 kHz or 1.6 kHz. The hearing aid operational measurements are performed per ANSI S3.22-2014.

4.2. Desired ABM signal and Undesired ABM Field Qualification Requirements
 2G GSM Operating Modes If the 2G GSM operating mode(s) are selected for qualification, the qualifying measurement points shall fulfil the requirements of section 6.6.2 of ANSI C63.19; both the primary and secondary group requirements shall be met:  The primary group shall include at least 25 measurement points.  The secondary group shall include at least 125 contiguous measurement points.
 Non-2G GSM Operating Modes The goal of this requirement is to ensure an adequate area where desired ABM signal is sufficiently strong to be heard clearly and a larger area where undesired ABM field is sufficiently low as to avoid undue annoyance. Qualifying measurement points shall fulfill the requirements of section 6.6.2 of ANSI C63.19; both the primary and secondary group requirements shall be met:  The primary group shall include at least 75 measurement points.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 9 of 28

REPORT No.SZ23120301S04
 The secondary group shall include at least 300 contiguous measurement points.

Fig 4.1 An example of a qualifying desired ABM signal, undesired ABM field scan
4.3. Frequency Response
The frequency response of the perpendicular component of the magnetic field, measured in 1/3 octave bands, shall follow the response curve specified in this sub-clause, over the frequency range 300 Hz to 3 kHz.

Fig 4.2 Magnetic field frequency response for WDs with field strength  ­15 dB (A/m) at 1 kHz

Fig 4.3 Magnetic field frequency response for WDs with a field that exceeds ­15 dB (A/m) at 1 kHz

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 10 of 28

REPORT No.SZ23120301S04
5. HAC (T-Coil) Measurement System
5.1. T-Coil Measurement Setup

Fig 5.1 SPEAG T-Coil System Configurations

Note:

1. Per C63.19 & KDB 285076 D02, define the all applicable input audio level:

Standard

Protocol

Input Level (dBm0)

TIA-2000

CDMA

-18

TIA/EIA-136

TDMA (50 Hz)

-18

J-STD-007

GSM (217 Hz)

-16

T1/T1P1/3GPP (See Note 1)

UMTS (WCDMA)

-16

iDEN

TDMA (22 Hz and 11 Hz)

-18

VoIP (See Note 2)

Voice over Internet Protocol

-16

Note 1: For UMTS (Universal Mobile Telecommunications System), refer to 3GPP TS26.131 and

TS26.132.

Note 2: VoIP is used in this table as a general term specifying a group of voice services that use -16

dBm0 as their normal acoustic level. The group includes a variety of voice services, including

Voice-over-LTE (VoLTE), Voice-over-IP-multimedia-subsystem (VoIMS), Voice-over-Wi-Fi (VoWiFi) and

similar services. For 3G, LTE, and WLAN terminals used for Commercial Mobile Radio Service (CMRS)

based telephony, refer to 3GPP TS26.131 and TS26.132.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 11 of 28

REPORT No.SZ23120301S04
2. A communication base station CMU200 is used for testing GSM / UMTS / CDMA, and it's "Decode Cal" and "Codec Cal" with audio option B52 and B85 to set the correct audio input level.
3. CMU200 is able to output 1 kHz audio signal equivalent to 3.14dBm0 at "Decode Cal", the signal reference is used to adjust the AMMI gain setting to reach -16dBm0 for GSM/UMTS and -18dBm0 for CDMA.
4. The callbox of CMW500 is used for VoLTE over IMS and VoWiFi over IMS T-Coil measurement, the data application unit of the CMW500 was used to simulate the IP multimedia subsystem server. And the CMW500 can be manually configured to ensure and control the speech input level result is -16dBm0 for VoLTE and -20dBm0 for VoWiFi when the device during the IMS connection.
5. The OTT VoIP call is tested on the data application unit of CMW500 connection to the internet.
5.2. Base Station Gain Factor
1. The Required gain factor for the specific signal shall typically be multiplied by this factor to achieve approx. the same level as for the 1 kHz sine signal.
2. The calculation formula as below showing how to determine the input level for air interface for this device.

<Input level determination>

Gain Value

Full Scaled

(linear)

Voltage (V)

-

1.5

100

9.31

<Base station gain factor calculation>

dBm0
3.14 5.6 -16

dB
40 19.38

AMMI Audio Out 0.5 2.96

AMCC Coil Out 3.14
-15.38 -16

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 12 of 28

REPORT No.SZ23120301S04

Signal Type
1kHz sine 48k_voice_1kHz 48k_voice_300-3000

Duration (s)
1 2

Peak to RMS (dB) 3 16.4 21.8

RMS (dB)
0 -12.8 -18.7

Gain Factor
1 4.35 8.51

Gain Setting
8.17 40.32 78.96

5.3. T-Coil Measurement Reference Plane

Fig 5.2 WD measurement and reference planes for Fig 5.3 Device Under Test Positioning under the Test

RF emission measurements

Arch

Note:

1. The reference plane is the planar area that contains the highest point in the area of the phone that

normally rests against the user's ear. It is parallel to the centerline of the receiver area of the phone and

is defined by the points of the receiver-end of the WD handset, which, in normal handset use, rest

against the ear.

2. The measurement plane is parallel to, and 10 mm in front of, the reference plane.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 13 of 28

REPORT No.SZ23120301S04
3. The reference axis is normal to the reference plane and passes through the center of the acoustic output (or the center of the hole array); or may be centered on or near a secondary inductive source. The actual location of the reference axis and resultant measurement area shall be noted in the test report.
4. The measurement area shall be 50 mm by 50 mm. The measurement area for both desired ABM signal and undesired ABM field may be located where the transverse magnetic measurements are optimum with regard to the requirements. However, the measurement area should be in the vicinity of the acoustic output of the WD and shall be located in the same half of the phone as the WD receiver. In a WD handset with a centered receiver and a circularly symmetrical magnetic field, the measurement axis and the reference axis would coincide.
5. Measurements of desired ABM signal strength and undesired ABM field are made at 2.0 mm ± 0.5 mm or 4 mm intervals in an X-Y measurement area pattern over the entire measurement area (676 measurement points total); either all measured, or measured plus interpolated, per 6.4 of ANSI C63.19.
6. Desired ABM signal frequency response is measured at a single location at or near the maximum desired ABM signal strength location.
7. The actual locations of the measurement points shall be noted in the test report.
5.4. System Validation
For correct and calibrated measurement of the voltages and ABM filed, DASY will perform a calibration job follows below: 1. In phase 1, the audio output is switched off, and a 200 mW symmetric rectangular signal of 1 kHz is
connected directly to both channels of the sampling unit (Coil in, Probe in). 2. In phase 2, the audio output is off, and a 20 mW symmetric 100 Hz signal is internally connected. The
signals during phases 1 and 2 are available at the output on the rear panel of the AMMI. However, the output must not be loaded, in order to avoid influencing the calibration, an RMS voltmeter would indicate 100mWRMS, during the second phase after the first two phases, the two input channels are both calibrated for absolute ants of voltages. The resulting factors are displayed above the multi-meter window. 3. After phases 1 and 2, the input channels are calibrated to measure exact voltages. This is required to use the inputs for measuring voltages with their peak and RMS value. 4. In phase 3, a mulit-sine signal covering each third-octave band from 50 Hz to 10 kHz is generated and applied to both audio outputs. The probe should be positioned in the center of the AMCC and aligned in the z-direction, the filed orientation of the AMCC. The "Coil In" channel is measuring the voltage over the AMCC internal shunt, which is proportional to the magnetic filed in the AMCC. At the same time, the "Probe In" channel samples the amplified signal picked up by the probe coil and provides a numerical integrator. The radio of two voltages in each third-octave filter leads to the spectral representation over the frequency band of interest. The coil signal is scaled in dBV, and the probe signal is first integrated and normalized to show dB A/m. The radio probe-to-coil at the frequency of 1 kHz is the sensitivity which will be used in the consecutive T-coil jobs.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 14 of 28

6. T-Coil Test Procedure
6.1. General Description

REPORT No.SZ23120301S04

T-Coil measurement follows Section 6.4 of ANSI C63.19-2019.

This sub clause describes the procedures used to measure the ABM (T-Coil) performance of the WD. Measurements shall be performed over a measurement area 50 mm square, in the measurement plane, as specified in A.3. The measurement area shall be scanned with a uniform measurement point spacing of 2.0 mm ± 0.5 mm in each X-Y axis of the plane, yielding 676 measurement points with approximately even spacing throughout the area.

Optionally, measurement point spacing may be increased to 4 mm, with interpolation employed to yield the required 676 equivalent measurement points distributed uniformly over the 50 mm square measurement area. Interpolated points shall be derived from the average of the linear representations of the field strengths of the nearest two or four equidistant measured points. The area of measurement is increased to a 52 mm square so that edge rows and columns of the required 50 mm square can be either measured or interpolated, with none extrapolated.

In addition to measuring the desired ABM signal levels, the weighted magnitude of the unintended signal shall also be determined. Weighting of the unintended and undesired ABM field shall be by the spectral and temporal weighting described in D.4 through D.6.

In order to assure that the required signal quality is measured, the measurement of the intended signal and the measurement of the unintended signal shall be made at the same locations. Measurements shall not include undesired influence from the WD's RF field; therefore, use of a coaxial connection to a base station simulator or non-radiating load might be necessary. However, even then with a coaxial connection to a base station simulator or non-radiating load there could still be RF leakage from the WD, which could interfere with the desired measurement. Pre-measurement checks should be made to avoid this possibility. All measurements shall be done with the WD operating on battery power with an appropriate normal speech audio signal input level given in Table 6.1. If the device display can be turned off during a phone call, then that may be done during the measurement as well. If tested with the display in the off state this shall be documented in the test report.

Measurements shall be performed with the probe coil oriented in the transverse direction, as illustrated in A.3, that is, aligned in the plane of the measurement area and perpendicular to the long dimension of the WD. A multi-stage sequence consists of first measuring the field strength of the desired T-Coil signal (desired ABM signal) that is useful to a hearing aid T-Coil at each specified measurement point. The undesired magnetic component (undesired ABM field) is then measured in the same transverse orientation at each of

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 15 of 28

REPORT No.SZ23120301S04
the same measurement points. At a single location only, taken at or near the highest desired ABM signal reading, the desired ABM signal frequency response shall be determined in a third measurement stage. The flowchart in Figure 6.3 illustrates this three-stage process.
To minimize the need to test every WD operating mode to the telecoil requirements of Clause 6, it is permissible to exclude some subset of supported configurations. For a given WD, every mode that supports voice communication shall be considered for telecoil testing. However, if it can be demonstrated that a certain configuration will not be the worst-case telecoil configuration, such configurations may be excluded from the full telecoil scans of 6.4.34 For example, operating modes may be pre-screened by scanning for both desired ABM signal and undesired ABM field at a lower measurement point density than the final scans, thus saving considerable testing time by eliminating configurations that are excellent performers from more detailed testing for worst-case. In any case, the specific methods and criteria used to determine which configurations are excluded for a WD shall be explicitly stated and justified in the test report. To be considered for exclusion from telecoil testing, operating modes shall also be shown to pass the frequency response requirements of 6.6.3.
Many factors could affect telecoil test results. RF power level and amplitude modulation characteristics as well as the specific current paths within the WD associated with the RF output stage(s), the display, and processing circuitry could affect the undesired ABM field. Audio codec implementation and acoustic receiver characteristics could also affect the desired ABM signal). Therefore, any justifications for exclusions should be thorough documented. If an operating mode is under user control and instructions on how to place the WD in a less interfering condition is in the user instructions, those instructions may be followed in configuring the device for testing.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 16 of 28

6.2. T-Coil Test Flow
This section follows ANSI C63.19-2019 section 6.4.1:

REPORT No.SZ23120301S04

Fig 6.1 WD T-Coil signal test flowchart Note: The following steps summarize the basic test flow for determining desired ABM signal and undesired ABM field. These steps assume that a sine wave or narrowband 1/3 octave signal can be used for the measurement of desired ABM signal level. An alternative procedure, yielding equivalent results, using a broadband excitation is described in 6.5 of ANSI C63.19-2019. 1. A validation of the test setup and instrumentation shall be performed. This may be done using a TMFS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 17 of 28

REPORT No.SZ23120301S04
or Helmholtz Coil. Measure the emissions and confirm that they are within tolerance of the expected values. 2. Confirm that equipment that requires calibration has been calibrated, and that the noise level meets the requirements given in 6.3.2. 3. Position the WD in the test setup and connect the WD RF connector to a base station simulator or a non-radiating load (if necessary to control RF interference in the measurement equipment) as shown in Figure 6.1 or Figure 6.2. 4. The drive level to the WD is set such that the reference input level specified in Table 6.1 is input to the base station simulator (or manufacturer's test mode equivalent) in the 1 kHz, 1/3 octave band. This drive level shall be used for the T-Coil signal test (desired ABM signal) at f = 1 kHz. Either a sine wave at 1025 Hz, or a voice-like signal, band-limited to the 1 kHz 1/3 octave, as specified in 6.4.3, shall be used for the reference audio signal. If interference is found at 1025 Hz an alternative nearby reference audio signal frequency may be used.35 The same drive level will be used for the desired ABM signal frequency response measurements at each 1/3 octave band center frequency. The WD volume control may be set at any level up to maximum, provided that a signal at any frequency at maximum modulation would not result in clipping or signal overload. 5. At each measurement location over the measurement area and in the transverse orientation, measure and record the desired 1 kHz T-Coil magnetic signal (desired ABM signal) as described in Step c). 6. At or near a location representing a maximum in the just-measured desired ABM signal, measure and record the desired T-Coil magnetic signals (desired ABM signal at fi) as described in 6.4.5.2 in each individual ISO 266:1975 R10 standard 1/3 octave band. The desired audio band input frequency (fi) shall be centered in each 1/3 octave band maintaining the same drive level as determined in Step c), and the reading taken for that band. Equivalent methods of determining the frequency response may also be employed, such as fast Fourier transform (FFT) analysis using noise excitation or input­output comparison using simulated speech. The full-band integrated or half-band integrated probe output, as described in D.9, may be used, as long as the appropriate calibration curve is applied to the measured result, so as to yield an accurate measurement of the field magnitude. (The resulting measurement shall be an accurate measurement in dB (A/m).) Compare the frequency response found to the requirements of 6.6.3. 7. At the same locations measured in Step d), measure and record the undesired broadband audio magnetic signal (undesired ABM field) with no audio signal applied (or digital zero applied, if appropriate) using the specified spectral weighting, the half-band integrator followed by the temporal weighting. 8. Calculate and record the location and number of the measurement points that satisfy both the minimum desired ABM signal level and the maximum undesired ABM field level specified in 6.6.2. Compare this to the requirements in 6.6.4 and record the result. 9. Calculate and record the location and number of the measurement points that satisfy the maximum undesired ABM field level and distribution requirements specified in 6.6.4.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 18 of 28

7. Test Equipment List

REPORT No.SZ23120301S04

Manufacturer
SPEAG
SPEAG SPEAG SPEAG SPEAG SPEAG SPEAG
R&S R&S

Name of Equipment
DOSIMETRIC ASSESSMENT SYSTEM Software
Audio Magnetic 1D Field Probe Audio Magnetic Calibration Coil
Audio Measuring Instrument Test Arch Phantom Audio Holder
Data Acquisition Electronics Base Station Base Station

Type/Model

Serial No. / SW Version

Calibration Last Cal. Due Date

cDASY6 HAC

V1.2

NCR

NCR

AM1DV3 AMCC AMMI N/A N/A DAE4 CMU200
CMW500

1048 1044 1032 N/A 1094 480 107082 165755

2023.06.13 NCR NCR NCR NCR
2023.09.19 2023.06.21 2024.01.25

2024.06.12 NCR NCR NCR NCR
2024.09.18 2024.06.20 2025.01.24

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 19 of 28

8. Summary Test Results
8.1. Test Guidance

REPORT No.SZ23120301S04

1. The middle channel of each frequency band is used for T-Coil testing according ANSI C63.19-2019. 2. For VoLTE radio configuration investigation is choose either one codec and an investigation was
performed on all frequency band, data rates and modulations and RB configuration to determine the radio configuration to be used for testing, the following tests results which the worst case configuration would be remarked to be used for the testing for the handset. 3. According to KDB 285076, reporting results involves Air Interface Investigation defined following process: 1) Ratio configuration Investigation: The worst radio configuration (e.g. bandwidth, modulation data
rate, subcarrier spacings, and resource blocks) should be investigated and documented. 2) Codec Investigation to determine the worst-case codec for each voice service, using the worst-case
codec for a voice service, a range of channels and bands tested. 3) Using a frequency near the center of the frequency band to test T-Coil per ANSI C63.19-2019
section 6.3.3. 4. For 5G VoWiFi, the worst frequency band of 802.11a would be selected to test other wireless modes. 5. This device was tested under the maximum volume, backlight off and mute on. 6. HAC mode would be active to improve the audio signal to comply with the T-Coil performance of ANSI
C63.19-2019. 7. The device have similar frequency in LTE bands: LTE B2/25, LTE Band 12/17, LTE Band 4/66 since the
supported frequency spans for the smaller LTE bands are completely cover by the larger LTE bands, therefore, only larger LTE bands were required to be tested for hearing-aid compliance.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 20 of 28

8.2. Test Results

REPORT No.SZ23120301S04

 GSM Test Results <Codec Investigation>

Wireless Band &
Channel

Orientation

Codec Bites (Kbps)

Primary Group Contiguous Point Count

Secondary Group
Contiguous Point Count

Secondary Secondary Frequency Group Max Group Max
Response Longitudinal Transverse

AMR-NB 4.75

225

282

17

26

PASS

AMR-NB 12.2

207

253

17

26

PASS

GSM850 /189 Transversal (Y)

AMR-WB 6.60

209

267

18

26

PASS

AMR-WB 12.65 217

255

17

26

PASS

Note: The worst codec of AMR-NB 12.2Kbps was selected for air interface Investigation.

<Air Interface Investigation>

Air Interface

Mode

Primary Channel Group
Contiguous Point Count

Secondary Group
Contiguous Point Count

Secondary Secondary Ambient Group Max Group Max Noise Longitudinal Transverse dB (A/m)

Frequency Response

GSM 850 GSM Voice 189

207

253

17

26

-53.87

PASS

GSM 1900 GSM Voice 661

193

235

16

26

-53.87

PASS

 UMTS Test Results <Codec Investigation>

Wireless Band &
Channel

Orientation

Codec Bites (Kbps)

Primary Group Contiguous Point Count

Secondary Group
Contiguous Point Count

Secondary Secondary Group Max Group Max Frequency
Response Longitudinal Transverse

AMR-NB 4.75

262

348

19

26

PASS

WCDMA II /

AMR-NB 12.20 Transversal (Y)

245

345

18

26

PASS

9400

AMR-WB 6.60

257

369

19

26

PASS

AMR-WB 12.65 266

363

19

26

PASS

Note: The worst codec of AMR-NB 12.2Kbps was selected for air interface Investigation.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 21 of 28

REPORT No.SZ23120301S04

<Air Interface Investigation>

Air Interface

Mode

Primary Group Channel Contiguous Point Count

Secondary Group
Contiguous Point Count

Secondary Secondary Ambient Group Max Group Max Noise Longitudinal Transverse dB (A/m)

Frequency Response

WCDMA II

AMR

9400

245

345

18

26

-53.87

PASS

WCDMA IV

AMR

1413

246

345

18

26

-53.87

PASS

WCDMA V

AMR

4182

228

344

18

26

-53.87

PASS

 VoLTE Test Results <Codec Investigation>

Wireless Band / Bandwidth / Channel

Orientation

Codec Bites (Kbps)

Primary Group Contiguous Point Count

Secondary Group
Contiguous Point Count

Secondary Secondary Frequency
Group Max Group Max Response
Longitudinal Transverse

AMR-NB 4.75

261

486

26

26

PASS

AMR-NB 12.20

241

482

26

26

PASS

AMR-WB 6.60

262

492

26

26

PASS

AMR-WB 12.65 266

496

26

26

PASS

LTE Band 25 /

EVS-SWB 9.6

245

507

26

26

PASS

Transversal (Y)

20MHz/ 26365

EVS-SWB 13.2

248

516

26

26

PASS

EVS-WB 5.9

254

494

26

26

PASS

EVS-WB 13.2

262

500

26

26

PASS

EVS-NB 5.9

243

497

26

26

PASS

EVS-NB 13.2

246

507

26

26

PASS

Note: The worst codec of AMR-NB 12.2Kbps was selected for air interface Investigation.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 22 of 28

REPORT No.SZ23120301S04

<Radio Configuration Investigation>

Air Interface

Bandwidth (MHz)

Modulation RB Offset

Probe Position

Primary Group Contiguous Point
Count

Frequency Response

LTE Band 25

20

QPSK

1#0

Transversal (Y)

241

PASS

LTE Band 25

20

QPSK

100#0 Transversal (Y)

254

PASS

LTE Band 25

20

16QAM

1#0

Transversal (Y)

244

PASS

LTE Band 25

20

64QAM

1#0

Transversal (Y)

261

PASS

LTE Band 25

15

QPSK

1#0

Transversal (Y)

249

PASS

LTE Band 25

10

QPSK

1#0

Transversal (Y)

247

PASS

LTE Band 25

5

QPSK

1#0

Transversal (Y)

259

PASS

LTE Band 25

1.4

QPSK

1#0

Transversal (Y)

254

PASS

Note: The worst radio configuration highlight about would be selected for other air interface measurement.

<Air Interface Investigation>

Air Interface

Mode

Primary Group Channel Contiguous Point Count

Secondary Group
Contiguous Point Count

Secondary Secondary Ambient Group Max Group Max Noise Longitudinal Transverse dB (A/m)

Frequency Response

LTE Band 5 QPSK/1#0 20525

455

492

26

26

-53.87

PASS

LTE Band

12/17

QPSK/1#0 23095

253

507

26

26

-53.87

PASS

LTE Band 25/2 QPSK/1#0 26365

241

482

26

26

-53.87

PASS

LTE Band 26 QPSK/1#0 26865

263

508

26

26

-53.87

PASS

LTE Band 41 QPSK/1#0 40620

390

433

22

26

-53.87

PASS

LTE Band 66/4 QPSK/1#0 132322

243

497

26

26

-53.87

PASS

LTE Band 71 QPSK/1#0 133322

253

498

26

26

-53.87

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 23 of 28

REPORT No.SZ23120301S04

 VoWiFi Test Results <Codec Investigation>

Wireless Band Orientation
/ Channel

Codec Bites (Kbps)

Primary Group Contiguous Point Count

Secondary Group
Contiguous Point Count

Secondary Secondary Frequency
Group Max Group Max Response
Longitudinal Transverse

AMR-NB 4.75

325

430

26

26

PASS

AMR-NB 12.20

315

422

26

26

PASS

AMR-WB 6.60

336

443

26

26

PASS

AMR-WB 12.65 320

434

26

26

PASS

WLAN 2.4GHz

EVS-SWB 9.6

334

438

26

26

PASS

Transversal (Y)

7

EVS-SWB 13.2

335

447

26

26

PASS

EVS-WB 5.9

338

442

26

26

PASS

EVS-WB 13.2

324

443

26

26

PASS

EVS-NB 5.9

324

446

26

26

PASS

EVS-NB 13.2

329

437

26

26

PASS

Note: The worst codec of AMR-NB 12.2Kbps was selected for air interface Investigation.

<Radio Configuration Investigation>

Wireless Band Air Interface

Data Rate Channel

Probe Position

Primary Group Contiguous Point
Count

Frequency Response

802.11b

1Mbps

7

Transversal (Y)

315

PASS

802.11g

6Mbps

7

Transversal (Y)

451

WLAN 2.4GHz

802.11n-HT20

MCS0

7

Transversal (Y)

289

PASS PASS

802.11n-HT40

MCS0

7

Transversal (Y)

298

PASS

WLAN 5.2GHz

802.11a

6Mbps

44

Transversal (Y)

398

PASS

WLAN 5.3GHz

802.11a

6Mbps

60

Transversal (Y)

386

PASS

WLAN 5.5GHz

802.11a

6Mbps

120

Transversal (Y)

364

PASS

WLAN 5.8GHz

802.11a

6Mbps

157

Transversal (Y)

356

PASS

Note: The worst radio configuration highlight about would be selected for other air interface measurement.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 24 of 28

REPORT No.SZ23120301S04

<Air Interface Investigation>

Primary Group Wireless Band Air Interface Channel Contiguous Point Count

Secondary Group
Contiguous Point Count

Secondary Secondary Ambient Group Max Group Max Noise Longitudinal Transverse dB (A/m)

Frequency Response

802.11b

7

315

422

26

26

-53.87

PASS

802.11g

7

451

540

26

26

-53.87

PASS

WLAN 2.4GHz

802.11n20 7

289

397

26

26

-53.87

PASS

802.11n40 7

298

408

26

26

-53.87

PASS

WLAN 5.2GHz 802.11a

44

398

500

26

26

-53.87

PASS

WLAN 5.3GHz 802.11a

60

386

509

26

26

-53.87

PASS

WLAN 5.5GHz 802.11a 120

364

515

26

26

-53.87

PASS

802.11a 157

356

455

26

26

-53.87

PASS

802.11n-20 157

453

546

26

26

-53.87

PASS

802.11n40 159

345

449

26

26

-53.87

PASS

WLAN 5.8GHz

802.11ac20 157

302

506

26

26

-53.87

PASS

802.11ac40 159

250

460

26

26

-53.87

PASS

802.11ac80 155

309

518

26

26

-53.87

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 25 of 28

9. Uncertainty Assessment

REPORT No.SZ23120301S04

Uncertainty of Audio Band Magnetic Measurements

Error Description

Uncertainty Value (±%)

Probe Sensitivity

Reference level

3.0

AMCC geometry

0.4

AMCC current

1.0

Probe positioning during calibrate

0.1

Noise contribution

0.7

Frequency slope

5.9

Probe System

Repeatability/drift

1.0

Linearity/dynamic range

0.6

Acoustic noise

1.0

Probe angle

1.0

Spectral processing

0.9

Integration time

0.6

Field disturbation

0.2

Test Signal

Reference signal spectral response

0.6

Positioning

Probe positioning

1.9

Phantom thickness

0.9

EUT positioning

1.9

External contributions

RF interference

0.0

Test signal variation

2.0

Combined Std. Uncertainty

Combined Std. Uncertainty (ABM Field)

Expanded STD Uncertainty

Probe Distance
N R R R R R
R R R R R N R
R
R R N
R R

Standard Standard

Div.

(Ci) (Ci) Uncertainty Uncertainty

ABMd ABMu (ABMd)

(ABMu)

(±%)

(±%)

1

1

1

3.0

3.0

1.732 1

1

0.2

0.2

1.732 0.7 0.7

0.6

0.6

1.732 1

1

0.1

0.1

1.732 0.0143 1

0.0

0.4

1.732 0.1 1

0.3

3.5

1.732 1

1

0.6

0.6

1.732 1

1

0.4

0.4

1.732 0.1 1

0.1

0.6

1.732 1

1

0.6

0.6

1.732 1

1

0.5

0.5

1

1

5

0.6

3.0

1.732 1

1

0.1

0.1

1.732 0

1

0.0

0.4

1.732 1

1

1.1

1.1

1.732 1

1

0.5

0.5

1.732 1

1

1.1

1.1

1.732 1 0.3

0.0

0.0

1.732 1

1

1.2

1.2

3.9

6.0

7.8

11.0

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 26 of 28

Annex A General Information

REPORT No.SZ23120301S04

1. Identification of the Responsible Testing Laboratory

Laboratory Name:

Shenzhen Morlab Communications Technology Co., Ltd.

Laboratory Address:

FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block

67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

Telephone:

+86 755 36698555

Facsimile:

+86 755 36698525

2. Identification of the Responsible Testing Location

Name: Address:

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 27 of 28

Annex B Test Setup Photos
The annex B will be submitted separately.

REPORT No.SZ23120301S04

Annex C Plots of T-Coil Test Results
The annex C will be submitted separately.

Annex D DASY Calibration Certificate
The annex D will be submitted separately.

****** END OF MAIN REPORT ******

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 28 of 28


Acrobat Distiller 11.0 (Windows)