HD 271 S1

LAB02

RF Exposure Report

SHENZHEN HYSNOX TECHNOLOGY CO., LTD HY01S Bluetooth Headset 2AZ3F-HY01S 2AZ3FHY01S hy01s

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=5575084
Shenzhen Huaxia Testing Technology Co., Ltd

1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China

Telephone: Fax: Website:

+86-755-26648640 +86-755-26648637 www.cqa-cert.com

Report Template Version: V05 Report Template Revision Date: 2021-11-03

RF Exposure Evaluation Report

Report No. :

CQASZ20211101913E-02

Applicant:

SHENZHEN HYSNOX TECHNOLOGY CO., LTD

Address of Applicant:

205, Floor 2, Xingyue Building, Shichang Road, Taoyuan Community, Dalang Street, LongHua Dist., Shenzhen, GuangDong

Equipment Under Test (EUT):

Product:

HYSNOX Helmet Bluetooth Intercom Headset

Model No.:

HY-01, HY-01S, HY-02, HY-02A, HY-06, HY-08, HY-10S, HY-10A, HY-10B,

HY-1006, HY-1008, HY-1009, SN-01, SN-02, SN-02A, SN-03, SN-05, SN-06A,

Test Model No.: Brand Name: FCC ID:

SN-08, SN-08A HY-01 HYSNOX 2AZ3F-HY01S

Standards:

47 CFR Part 1.1307

47 CFR Part 1.1310

KDB447498D01 General RF Exposure Guidance v06

Date of Receipt:

2021-11-03

Date of Test:

2021-11-03 to 2021-11-26

Date of Issue:

2021-12-03

Test Result :

PASS*

*In the configuration tested, the EUT complied with the standards specified above

Tested By:

( Lewis Zhou )

Reviewed By:

( Rock Huang )

Approved By:

( Jack ai)

The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can't be reproduced except in full.

Shenzhen Huaxia Testing Technology Co., Ltd
Report No.: CQASZ20211001913E-02

1 Version

Revision History Of Report

Report No. CQASZ20211101913E-02

Version Rev.01

Description Initial report

Issue Date 2021-12-03

Page:2 of 6

Shenzhen Huaxia Testing Technology Co., Ltd
Report No.: CQASZ20211001913E-02
2 Contents
Page 1 VERSION...................................................................................................................................................................... 2 2 CONTENTS.................................................................................................................................................................. 3 3 GENERAL INFORMATION....................................................................................................................................... 4
3.1 CLIENT INFORMATION................................................................................................................................................4 3.2 GENERAL DESCRIPTION OF EUT............................................................................................................................. 4 4 SAR EVALUATION.....................................................................................................................................................5 4.1 RF EXPOSURE COMPLIANCE REQUIREMENT...........................................................................................................5
4.1.1 Standard Requirement..................................................................................................................................5 4.1.2 Limits............................................................................................................................................................... 5 4.1.3 EUT RF Exposure......................................................................................................................................... 6
Page:3 of 6

Shenzhen Huaxia Testing Technology Co., Ltd
Report No.: CQASZ20211001913E-02

3 General Information

3.1 Client Information

Applicant: Address of Applicant:
Manufacturer: Address of Manufacturer:
Factory: Address of Factory:

SHENZHEN HYSNOX TECHNOLOGY CO., LTD
205, Floor 2, Xingyue Building, Shichang Road, Taoyuan Community, Dalang Street, LongHua Dist., Shenzhen, GuangDong
SHENZHEN HYSNOX TECHNOLOGY CO., LTD
205, Floor 2, Xingyue Building, Shichang Road, Taoyuan Community, Dalang Street, LongHua Dist., Shenzhen, GuangDong
SHENZHEN HYSNOX TECHNOLOGY CO., LTD
205, Floor 2, Xingyue Building, Shichang Road, Taoyuan Community, Dalang Street, LongHua Dist., Shenzhen, GuangDong

3.2 General Description of EUT

Product Name:

HYSNOX Helmet Bluetooth Intercom Headset

Model No.:

HY-01, HY-01S, HY-02, HY-02A, HY-06, HY-08, HY-10S, HY-10A, HY-10B,
HY-1006, HY-1008, HY-1009, SN-01, SN-02, SN-02A, SN-03, SN-05, SN-06A, SN-08, SN-08A

Test Model No.: Trade Mark:

HY-01 HYSNOX

Software Version: Hardware Version: Operation Frequency:

A2.0
A1.0 2402MHz~2480MHz

Bluetooth Version:

Bluetooth v5.0

Modulation Technique:

Frequency Hopping Spread Spectrum(FHSS)

Modulation Type:

GFSK, /4DQPSK, 8DPSK

Transfer Rate:

1Mbps/2Mbps/3Mbps

Number of Channel:

79

Hopping Channel Type:

Adaptive Frequency Hopping systems

Product Type:

Mobile

Portable

Fix Location

Test Software of EUT:

Blue Test3

Antenna Type:

Chip antenna

Antenna Gain:

4.97dBi

Power Supply:

lithium battery:DC3.7V, 900mAh, 3.33Wh, Charge by DC5.0V

Page:4 of 6

Shenzhen Huaxia Testing Technology Co., Ltd
Report No.: CQASZ20211001913E-02
4 SAR Evaluation
4.1 RF Exposure Compliance Requirement
4.1.1 Standard Requirement
According to KDB447498D01 General RF Exposure Guidance v06 4.3.1. Standalone SAR test exclusion considerations
Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied.
4.1.2 Limits
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances  50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [f(GHz)]  3.0 for 1-g SAR and  7.5 for 10-g extremity SAR, where
f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation17 The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is  50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion
Page:5 of 6

Shenzhen Huaxia Testing Technology Co., Ltd
Report No.: CQASZ20211001913E-02

4.1.3 EUT RF Exposure
Measurement Data
Test channel
Lowest(2402MHz) Middle(2441MHz) Highest(2480MHz)
Test channel
Lowest(2402MHz) Middle(2441MHz) Highest(2480MHz)
Test channel
Lowest(2402MHz) Middle(2441MHz) Highest(2480MHz)

GFSK mode

Peak Output Power

Tune up tolerance

(dBm)

(dBm)

-4.120

-4.0±1

-3.350

-3.0±1

-2.770

-2.5±1

/4DQPSK mode

Peak Output Power

Tune up tolerance

(dBm)

(dBm)

-3.330

-3.0±1

-2.590

-2.5±1

-2.020

-2.0±1

8DPSK mode

Peak Output Power

Tune up tolerance

(dBm)

(dBm)

-2.960

-2.5±1

-2.190

-2.0±1

-1.620

-1.5±1

Maximum tune-up Power

(dBm)

(mW)

-3.0

0.501

-2.0

0.631

-1.5

0.708

Maximum tune-up Power

(dBm)

(mW)

-2.0

0.631

-1.5

0.708

-1.0

0.794

Maximum tune-up Power

(dBm)

(mW)

-1.5

0.708

-1.0

0.794

-0.5

0.891

Worst case: 8DPSK

Channel

Maximum Peak Conducted
Output Power (dBm)

Tune up tolerance
(dBm)

Maximum tuneup Power
(dBm) (mW)

Lowest (2402MHz)

-2.960

-2.5±1

-1.5 0.078

Middle (2441MHz)

-2.190

-2.0±1

-1.0 0.794

Highest (2480MHz)

-1.620

-1.5±1

-0.5 0.891

Conclusion: the calculated value 3.0, SAR is exempted.

Calculated value
0.219 0.248 0.281

Exclusion threshold
3.0

Remark: The Max Conducted Peak Output Power data refer to report Report No.: CQASZ20211001913E-01

*** End of Report ***