User Manual for PROGRESSIVE AUTOMATION models including: TY-05-30, TY-05-40, TY-05-50, Drop Down TV Lift

TY-05-30 Data Sheet

Do not sit or stand on the TV lift. Do not crawl or lie under the TV lift. Do not open any of the components - the linear actuator, control box or remote.

TY-05 User Manual v1.0


File Info : application/pdf, 7 Pages, 2.55MB

PDF preview unavailable. Download the PDF instead.

3023871
TY-05-30 / TY-05-40 / TY-05-50 User Manual

Contents

Caution/Liability Dimensions in Inches Specifications Electronics Hardware Assembly Instructions

Page 2 Page 3 Page 3
Page 4 Page 5-7

Caution
Make sure no obstacles are in the lift's path. Make sure the lift is not touching any walls. Make sure all cords are appropriate length to
accommodate the change in height. Keep children away from electric TV lift, control units and remotes.
There is a risk of injury and electric shock Keep all electrical components away from liquids.
Do not sit or stand on the TV lift. Do not crawl or lie under the TV lift. Do not open any of the components - the linear actuator, control box or remote.
There is a danger of electric shock. This product is designed with a duty cycle of 10%
(2 min. on, 18 min. off).
Liability
The height adjustable TV lift contains electric motors and is designed for dry areas only. The TV lift is adjustable so that it can be positioned at the most ergonomically suitable height.
Any other use is at user's risk. Under no circumstances does the manufacturer accept warranty claims or liability claims for
damages caused from improper use or handling of the TV lift.
2

Dimensions in Inches
12.5 + Stroke Length + Stroke Length
35" for a 30" stroke 45" for a 40" stroke

Specifications

Model: TV Maximum Height: Wall Mount Measurements: Stroke Length: Weight: Speed at Full Load: Dynamic Load
Input Voltage: Output Voltage: Overload Protection: Duty Cycle: Limit Switch: IP Grade: Operational Temperature: Certification: Control Options:

TY-05-30

TY-05-40

TY-05-50

30" Stroke = 30" Tall

40" Stroke = 40" Tall

50" Stroke = 50" Tall

700mm x 500mm

700mm x 700mm

700mm x 1200mm

30"

40"

50"

25.5 lbs

38.5 lbs

40.3lbs

0.9"/sec

140 lbs

110 - 220 VAC

24VDC Fused

10% (2 minutes on, 18 minutes off)

Built-in, non-adjustable and externally mounting

IP20

-26ºC to +65ºC (-15ºF to 150ºF)

CE and RoHS

Wired and wireless

3

Electronics

Control Box
x 1
Hardware

Wireless Remote
x 1

Rocker Switch (Wire 35")
x 1

External Limit Switch (Wire 60")
x 1

Ceiling Cover Brackets x 2

Actuator Mounting Bracket x 1

Ceiling Cover x 1

Track Linear Actuator Support Column

x 1

x 1

TV Mounting Brackets x 4

TV Support Arms 30" x 2

TV Support Arms 36" x 2

Purpose P1 Ceiling Cover Brackets
P2 Ceiling Cover Brackets
P3 TV Support Arm
P4 TV Mounting Bracket
P5 Support Column (middle)
P5 Support Column (outside)
P6 Actuator Mounting Bracket

Name Hex Bolt M8x18
Nut M8 Flat Washer M8 Phillips Countersunk
Screw M5x12 Nut M5
Flat Washer M5 Hex Bolt M8x12 Nut M8 (spare parts) Flat Washer M8
Thumb Screw M5
Phillips Countersunk Screw M8x12
Hex Bolt M10x25 Locking Washer M10
Flat Washer M10 Hex Bolt M6x25 Locking Washer M6 Flat Washer M6
Clevis Pin
Cotter Pin

Quantity 4 4 4 4
4 4 4 4 4 4
4
2 2 2 4 4 4 1
1

4

Assembly Instructions
Tools needed: philips screwdriver, 5mm allen key, 6mm allen key, 8mm allen key, 8mm socket, 13mm
socket
1 Use the four M8x12 Phillips Countersunk Screws
from bag P4 to mount the TV Mounting Brackets to the back of your television. Please be aware that the supplied screws may not fit your television. Ensure that you have the appropriate TV mounting screws before continuing. Tighten until secure.

3 Use the four M5x12 screws, nuts and washers
from bag P2 to attach the Ceiling Cover to the Ceiling Cover Brackets. Tighten until secure.

2 Use the four M8x12 bolts, nuts and washers
from bag P3 to attach TV Support Arms to the Support Column. Either the 30" or 36" TV Support Arm can be used depending on which width suits the installed TV. Tighten until secure.

44

Use the four M8x18 bolts, nuts and washers from bag P1 to mount the assembled Ceiling Cover to the Support

Column. Tighten until secure.

5

Assembly Instructions

5 Use the Actuator Mount Bracket, Clevis Pin and Cotter Pin
from bag P6 to mount the top portion of the Track Linear Actuator to your installation. The bottom portion comes with an attached bracket for installation. The wood screws shown in the diagram are not included. Tighten until secure.

7 Now that your Drop Down TV Lift is assembled you can attach
your TV Mounting Brackets to the TV Support Arms using the four M8x12 screws. Tighten until secure.

6

For this step we recommend having at least two peope. From bag P6, use the four M6x25 bolts and washers for the smaller

holes on the outside and the two M10x25 bolts and washers for

the middle holes to mount the assembled Support Column to

the Track Linear Actuator. Install all of the bolts before

tightening to ensure proper alignment.

8 Your Drop Down TV Lift is now fully assembled and ready for
use.

6

Assembly Instructions
9 Pairing the Wireless Remote
Pairing the wireless remote is required before use. · Press and hold the UP and DOWN buttons on the wireless
remote while simultaneously pressing the button on the side of the control box for 10 seconds. The TV lift will raise after the remote pairing has been completed.
10 Changing Travel Functionality
To change the wireless remotes travel function from Momentary to Non-Momentary, hold the COM button for approximately 10 seconds.
11 External Limit Switch
Please keep in mind this procedure is completely optional and does not need to be set up in order for the TV Lift to operate. The external limit switch stops the lift from moving once it is pressed. Please note that the external limit switch will only operate in the extending direction. Install the switch in a way that it will be pressed while the lift is moving up and right before the ceiling cover touches the ceiling.
7

