Series PWS15 PURE WATER

require manual actuation. Watts Pure Water Series PWS15 water softeners are designed for point of use or point of entry applications where the benefits of softened water are required. These systems exchange scale forming calcium and magnesium ions with non-scale form-ing sodium ions to create soft water for a variety of applica-tions.

PDF preview unavailable. Download the PDF instead.

es-wq-pws15 ;
For Commercial Applications

ES-WQ-PWS15

Job Name ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ Job Location ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ Engineer ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ Approval ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­

Contractor ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ Approval ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ Contractor's P.O. No. ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ Representative ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­

Series PWS15
Commercial Water Softening Systems
Connection Size: 11/2" (40 mm) Flow Rates: Up to 55 gpm (208 lpm)
Watts Pure Water Series PWS15 water softening systems are highly efficient conventional cation exchange type water softeners. They are suitable for commercial applications ranging from 60,000 to 300,000 grains of hardness removal and flow rates up to 55 gallons per minute. Regeneration is meter demand initiated. All cycles of regeneration are fully automatic and do not require manual actuation.
Watts Pure Water Series PWS15 water softeners are designed for point of use or point of entry applications where the benefits of softened water are required. These systems exchange scale forming calcium and magnesium ions with non-scale forming sodium ions to create soft water for a variety of applications. Steam boiler make up water, water heater pretreatment, reverse osmosis pretreatment, sterilizer make up water, washing, and process water are all common applications for the Watts Pure Water Series PWS15 water softeners.
Softened water provides a wide variety of benefits from not introducing scale into pipes, valves, water heating equipment, heat exchangers, and cooling towers to reducing mineral build up in areas that see excessive splashing such as food preparation counters and sink areas. Softened water also conserves soaps and cleaning agents by eliminating the formation of soap curd, so your cleaners can work on cleaning not reacting with the hardness in your water.
Features
· Durable brass bodied control valve for years of service
· WQA Certified fully automatic metered demand control valve
· Sophisticated digital electronic controls that store operating history that can be accessed by the user
· Fully adjustable regeneration cycles
· Dry contact lock out switch for remote interface is standard
· WQA Certified high capacity resin
· Highly corrosion resistant WQA or NSF Certified fiberglass tanks
· Durable polypropylene lower distribution system
Standards
Control Valve- WQA Certified to NSF/ANSI Std. 61 and 372 Ion Exchange Resin- WQA Certified to NSF/ANSI Std. 61 Mineral Tank- WQA or NSF Certified to NSF/ANSI Std. 44 or 61

PURE WATER
Series PWS15
Specifications
A Watts Pure Water Series PWS15 water softening system shall be installed on the building's main water line just after it enters the building. The installation point shall be after any backflow prevention or pressure regulating valves. Other installation options are to install a system just before the water heater or other types of equipment needing the protection of softened water. In installations where dedicated cold water make up to a water heater is the installation point, a backflow preventer and a thermal expansion tank must be installed as well. The system shall be installed with a bypass valve to allow for the shut down and removal of the unit without interrupting the water supply to the building. The water softener shall be a down flow regenerated, metered demand, sodium cycle cation exchange type system with all components necessary for proper operation.
NOTICE
Electrical requirements are 120 volt 60 hertz. A local drain is required to accept drain water from the system. The feed water pressure must not fall below 25psi or exceed 125psi. Water temperature must not fall below 34°F or exceed 110°F (1 43°C). The system shall provide softened water measuring less than one grain per gallon of hardness as Calcium Carbonate when operated within the manufacturers operational specifications.
! WARNING
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

Dimensions - Weights
EE
F CC

DD BB

Feed Water Guidelines
pH . . . . . . . . . . . . . . . . . . . . . 6 to 10
Hardness (maximum) . . . . . . . Depends on customers acceptable hardness leakage level.
Water Pressure . . . . . . . . . . . 25psi to 125psi (171 kPa to 8.5 bar)
Temperature . . . . . . . . . . . . . 34 - 110°F (1 - 43°C)
Free Chlorine (maximum) . . . . 1mg/L
Iron (maximum) . . . . . . . . . . . 1mg/L
Oil and H2S . . . . . . . . . . . . . . None Allowed
Turbidity . . . . . . . . . . . . . . . . Less than 5.0 NTU
AA For all other guideline information please contact your Watts representative.

FRONT
FRONT

GG

NOTICE

The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product.

SIDE
SIDE

Model No.
PWS15121C11 PWS15121D11 PWS15121E11 PWS15121F11 PWS15121G11 PWS15121H11

A

in.

mm

547/8 1394

6615/16 1699

663/8 1686

68 1727

70 1778

763/8 1940

B

in.

mm

553/4 1416

677/8 1724

671/4 1708

69 1753

71 1803

771/4 1962

Dimensions

C

D

in.

mm

in.

mm

61 1549 1315/16 353

733/8 1864 1415/16 378

723/4 1848 1515/16 405

747/16 1890 181/8 460

767/16 1941 211/8 536

823/4 2102 241/8 613

E

in.

mm

19 483

1913/16 503

2013/16 528

2113/16 554

235/16 592

2413/16 630

F

in.

mm

18 457

18 457

18 457

24 610

24 610

30 762

G

in.

mm

40 1016

40 1016

40 1016

41 1041

50 1270

50 1270

WEIGHTS

in.

mm

210 95

240 109

320 145

380 173

585 266

710 323

Specifications

Model No.
PWS15121C11 PWS15121D11 PWS15121E11 PWS15121F11 PWS15121G11 PWS15121H11

Mineral Tank

TANK

RESIN GRAVEL

SIZE

Ft3

12" x 52" 2.0 30 lbs.

14" x 65" 3.0 60 lbs.

16" x 65" 4.0 80 lbs.

18" x 65" 5.0 100 lbs.

21" x 62" 7.0 100 lbs.

24" x 72" 10.0 200 lbs.

Brine Tank

TANK

SALT

size

fill

18x40 400

18x40 400

18x40 400

24x41 600

24x50 800

30x50 1400

Softening

CAPACITY

Max

min

60 K 40 K

90 K 60 K

120 K 80 K

150 K 100 K

210 K 140 K

300 K 200 K

Lbs. Salt Per

REGENERATION

max

MIN

30

12

45

18

60

24

75

30

105

42

150

60

Flow Rate & PressurE

SERV

DROP

BKW

GPM

PSI

GPM

15/20 15/25 4.0

17/22 15/25 5.0

25/40 15/25 7.0

30/50 15/25 11.0

35/53 15/25 13.0

40/55 15/25 15.0

Ordering Information

Model No.
PWS15121C11 PWS15121D11 PWS15121E11 PWS15121F11 PWS15121G11 PWS15121H11

DESCRIPTION
2 Cubic Foot Simplex Softener with Flow Meter 3 Cubic Foot Simplex Softener with Flow Meter 4 Cubic Foot Simplex Softener with Flow Meter 5 Cubic Foot Simplex Softener with Flow Meter 7 Cubic Foot Simplex Softener with Flow Meter 10 Cubic Foot Simplex Softener with Flow Meter

PIPE SIZE
1.5" 1.5" 1.5" 1.5" 1.5" 1.5"

SPACE REQUIRED D x W x h
18" x 42" x 75" 18" x 44" x 87" 18" x 46" x 87" 24" x 50" x 87" 24" x 52" x 84" 39" x 60" x 96"

WEIGHT

LBS

KGS

210 95

240 109

320 145

380 173

585 266

710 323

Notes: Capacities are based on resin manufacturer's data and are dependent upon influent water TDS, temperature, bed depth, and flow rates. Feed water must be free of oil and color. Pipe size, tank size, and space requirements are in inches. Flow rates listed at 25 psi drops are for intermittent peak flow rates and are not to be used as continuous flows.

A Watts Water Technologies Company ES-WQ-PWS15 1526

USA: Tel: (800) 224-1299 · Fax: (978) 794-1848 · Watts.com/PureWater Canada: Tel: (905) 332-4090 · Fax: (905) 332-7068 · Watts.ca/PureWater Latin America: Tel: (52) 81-1001-8600 · Fax: (52) 81-8000-7091 · Watts.com/PureWater
© 2015 Watts


Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Macintosh)