Installation Instructions

ALPHA 2 DRYER, Installation Instructions, MED6000AW0, MED7000AW0, MED8000AW0, WED88HEAW0, WED94HEAW0, WED96HEAW0, W10508904B

ALPHA, 2, DRYER;, Installation, Instructions;, MED6000AW0;, MED7000AW0;, MED8000AW0;, WED88HEAW0;, WED94HEAW0;, WED96HEAW0;, W10508904B

Johnson-Rauhoff

Installation Instructions

PDF preview unavailable. Download the PDF instead.

installation-instructions-W10777574-RevB
HybridCareTM Heat Pump Dryer
Installation Instructions

Sécheuse à pompe à chaleur HybridCareTM Instructions d'installation

Table of Contents

Table des matières

DRYER SAFETY......................................................................... 2 INSTALLATION REQUIREMENTS............................................ 3
Tools and Parts....................................................................... 3 LOCATION REQUIREMENTS.................................................... 4 DRAIN SYSTEM.......................................................................... 5 ELECTRICAL REQUIREMENTS - U.S.A. ONLY...................... 6 ELECTRIC DRYER POWER HOOKUP - CANADA ONLY....... 7 INSTALL LEVELING LEGS........................................................ 8 ELECTRICAL INSTALLATION - U.S.A. ONLY......................... 8
Power Supply Cord Connection............................................ 9 Direct Wire Connection........................................................ 11 CONNECT OUTLET HOSE...................................................... 14 LEVEL DRYER.......................................................................... 15 COMPLETE INSTALLATION CHECKLIST............................. 16 DOOR REVERSAL (OPTIONAL).............................................. 16 TROUBLESHOOTING.............................................................. 26

SÉCURITÉ DE LA SÉCHEUSE................................................ 27 EXIGENCES D'INSTALLATION............................................... 28
Outillage et pièces................................................................ 28 EXIGENCES D'EMPLACEMENT............................................. 29 SYSTÈME DE VIDANGE........................................................... 30 SÉCHEUSE ÉLECTRIQUE RACCORDEMENT À L'ALIMENTATION ÉLECTRIQUE CANADA SEULEMENT............................................................ 31 INSTALLATION DES PIEDS DE NIVELLEMENT................... 32 CONNEXION DU TUYAU DE SORTIE.................................... 32 RÉGLAGE DE L'APLOMB DE LA SÉCHEUSE....................... 33 ACHEVER L'INSTALLATION LISTE DE VÉRIFICATION....... 34 INVERSION DE LA PORTE (FACULTATIF)............................ 34 DÉPANNAGE..................................... COUVERTURE ARRIÈRE

Para una version de estas instrucciones en español, visite www.Whirlpool.com or www.maytag.com

INSTALLATION NOTES
Date of purchase:__________________________________ Date of installation:________________________________ Installer:_________________________________________ Model number:____________________________________ Serial number:____________________________________

NOTES CONCERNANT L'INSTALLATION
Date d'achat :______________________________________ Date d'installation :_________________________________ Installateur :_______________________________________ Numéro de modèle :_________________________________ Numéro de série :___________________________________

W10777574B W10777575B - SP

Dryer Safety
Certain internal parts are intentionally not grounded and may present a risk of electric shock only during servicing. Service Personnel ­ Do not contact the thermostat bracket while the appliance is energized.
2

Installation Requirements
TOOLS AND PARTS Gather the required tools and parts before starting installation.
Tools needed:

Parts supplied:

Flat-blade screwdriver

#2 Phillips screwdriver

Leveling legs (4)

6' (1829 mm) drain hose with couplers

Wire stripper (direct wire installations)

Channel locks

1/4" and 5/16" nut driver (recommended)

Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench

Cable ties (2)
Parts package is located in dryer drum. Check that all parts are included. NOTE: Do not use leveling legs supplied with dryer if installing with a pedestal or a stack kit.
If using a power supply cord: Use a UL-listed power supply cord kit marked for use with clothes dryers. The kit should contain: A UL-listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends. A UL-listed strain relief.
Additional Accessories: (Not supplied with dryer) Refer to your Use and Care Guide for information about accessories available for your dryer.

Utility knife

Tape measure

Level

Pliers

3

Location Requirements
Check code requirements. Some codes limit, or do not permit, installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Side view:

51 " min. (1314 mm)
31 " min. (806 mm)

You will need:
A separate 30 amp circuit.
If using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See "Electrical Requirements."
Floor must support dryer weight of 200 lbs. (90.7 kg). Also consider weight of companion appliance.
Level floor with maximum slope of 1" (25 mm) under entire dryer. If forward slope is greater than 1" (25 mm), water could run out from front of filter. Install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.
For garage installation, place dryer at least 18" (460 mm) above floor. If using a pedestal, you will need 18" (460 mm) to bottom of dryer.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
IMPORTANT: Do not operate, install, or store dryer where it will be exposed to water, weather, or at temperatures below 40°F (4°C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times.

DRYER DIMENSIONS Front view:

27" (686 mm)

Back view:
NOTE: Allow clearance behind dryer for proper drain hose routing and cooling fan ventilation. Push dryer back as far as possible and make sure drain hose is not crushed or kinked.

61/2" (165 mm)

Power cord/ cable
Water Cooling drain fan

297/8"* (759 mm)

131/2"

61/2"

(343 mm) (165 mm)

*Approx. measurement

IMPORTANT: Do not block cooling fan as your dryer may not operate properly.

383/4" Min. (984 mm)
39" Max. (990 mm)

4

Installation spacing for recessed area or closet installation All dimensions show recommended and minimum spacing allowed.
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door, floor, moldings, and drain system.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Recommended installation clearances (dryer only):

Drain System
Drain system can be installed using a floor drain, wall standpipe, floor standpipe, or laundry tub. Select method you need. IMPORTANT: To avoid siphoning, only 4.5" (114 mm) of drain hose should be inside standpipe. Always secure drain hose with cable tie.
Floor standpipe drain system

4.5" (114 mm)

max. 54" (1372 mm)
min. 30" (762 mm)

0" - 5"* (0 mm - 127 mm)

18" min. (457 mm)

3"
(76 mm) 48 in.2 min. (310 cm2)

Without pedestal

4.5" (114 mm)

max. 69" (1753 mm)
min. 30" (762 mm)

24 in.2 min. (155 cm2) 3" (76 mm)

1" (25 mm)

1" (25 mm)

With 15" matching pedestal
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum carry-away capacity: 17 gal. (64 L) per minute. A 1/4" (6 mm) diameter to 1" (25 mm) diameter Standpipe Adapter Kit is available. Top of standpipe must be at least 30" (762 mm) high; install no higher than 54" (1.37 m) from bottom of dryer. IMPORTANT: Only 4.5" (114 mm) of drain hose should be inside standpipe; do not force excess hose into standpipe.

*NOTE: 0" ( 0 mm) spacing is allowed behind dryer, providing drain hose is not kinked or pinched.

Wall standpipe drain system
4.5" (114 mm)

Mobile home ­ Additional installation requirements:
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

See requirements for floor standpipe drain system.

5

Laundry tub drain system

4.5" (114 mm)

max. 54" (1372 mm)
min. 30" (762 mm)

Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at least 30" (762 mm) above floor; install no higher than 54" (1.37 m) from bottom of dryer.
IMPORTANT: Only 4.5" (114 mm) of drain hose should lay on side of laundry tub. Do not lay the hose at the bottom of tub.
Floor drain system

Remove the U-bend at the end of the drain hose by cutting the hose at the end of the U-bend for the floor drain system as shown in the picture above. NOTE: Cut hose so that no more than 4.5" (114 mm) of the hose is in the floor drain to avoid siphoning.
Electrical Requirements U.S.A. Only
It is your responsibility:
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/ NFPA 70 ­ latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.
To supply the required 3- or 4-wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply (or 3- or 4-wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Electrical Connection
To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground conductor must be removed from the external ground connector (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground conductor is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor. The green ground wire of the 4-wire power cord must be secured to the dryer cabinet with the green ground screw.
If local codes do not permit the connection of a neutral ground wire to the neutral wire, see "Optional External Ground 3-wire connection" section.
A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations after 1996, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.

If using a power supply cord:
Use a UL-listed power supply cord kit marked for use with clothes dryers. The kit should contain:
A UL-listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
A UL-listed strain relief.

If your outlet looks like this:

Then choose a 4-wire power supply cord with

ring or spade terminals and UL-listed strain

relief. The 4-wire power supply cord, at least

4 ft. (1.22 m) long, must have four 10-gauge

copper wires and match a 4-wire receptacle of

NEMA Type 14-30R. The ground wire (ground

4-wire receptacle conductor) may be either green or bare. The

(14-30R)

neutral conductor must be identified by a white

cover.

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL-listed strain relief. The 3-wire power supply cord, at least 4 ft. (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) and be:
Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), covered with flexible metallic conduit. All current-carrying wires must be insulated.
10-gauge solid copper wire (do not use aluminum) at least 5 ft. (1.52 m) long.

6

 To supply the required 4-wire, single-phase, 120/240 volt, 60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
 This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure wall receptacle is within reach of dryer's final location.

Electric Dryer Power Hookup ­ Canada Only
Electrical Requirements

4-wire receptacle (14-30R)
 Do not use an extension cord. If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 8579325. For further information, please reference the "Assistance or Service" section of the "Use and Care Guide."
GROUNDING INSTRUCTIONS
I For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a quali ed electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not t the outlet, have a proper outlet installed by a quali ed electrician.
SAVE THESE INSTRUCTIONS

It is your responsibility:
 To contact a qualified electrical installer.
 To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

7

Install Leveling Legs 1. Prepare dryer for leveling legs

Electric Installation - U.S.A. Only
Before you start: disconnect power.
1. Choose electrical connection type
Power supply cord 4-wire receptacle (NEMA Type 14-30R). Go to "Power Supply Cord Connection."
Power supply cord 3-wire receptacle (NEMA Type 10-30R). Go to "Power Supply Cord Connection."

To avoid damaging floor, use a large flat piece of cardboard from dryer carton; place under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard.
NOTE: Residual water from factory testing may drain when dryer is laying on its side.
2. Screw in leveling legs

4-wire direct connection: Go to "Direct Wire Connection."
3-wire direct connection: Go to "Direct Wire Connection."
NOTE: If local codes do not permit connection of a cabinet-ground conductor to neutral wire, go to "Optional External Ground 3-wire connection." This connection may be used with either a power supply cord or a direct wire connection.
2. Remove terminal block cover

Using a wrench and tape measure, screw leveling legs into leg holes until bottom of foot is approximately 1/2" (13 mm) from bottom of dryer.
Now stand the dryer on its feet. Slide the dryer until it is close to its final location.

Remove hold-down screw and terminal block cover.

8

Power Supply Cord Connection

2. Attach power supply cord to strain relief

Power Supply Cord Strain Relief:
1. Attach power supply cord strain relief
A B C D

Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
If your outlet looks like this:
Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to "4-Wire Power Supply Cord Connection."
Power supply cord 3-wire receptacle (NEMA Type 10-30R): Go to "3-Wire Power Supply Cord Connection."
4-Wire Power Supply Cord Connection
IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

Remove the screws from a ¾" (19 mm) UL-listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections (C) into the hole below the terminal block opening (B) so that one tab is pointing up (A) and the other is pointing down (D), and hold in place. Tighten strain relief screws just enough to hold the 2 clamp sections (C) together.

4-wire receptacle (NEMA type 14-30R)

4 prong plug

Spade terminals with upturned ends

Ring terminals

9

1. Prepare to connect neutral ground wire and neutral wire

4. Connect remaining wires

E B
A

Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A).
2. Connect neutral ground wire and neutral wire

Connect remaining wires under outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to "Connect Outlet Hose."
3-Wire Power Supply Cord Connection
Use where local codes permit connecting cabinet-ground conductor to neutral wire.

B E

C

3-wire receptacle (NEMA type 10-30R)

3 prong plug

Connect neutral ground wire (E) and neutral wire (white or center) (C) of power supply cord under center terminal block screw (B). Tighten screw.
3. Connect ground wire

Spade terminals with upturned ends

Ring terminals

1. Remove center screw

A
B
F

Connect ground wire (F) (green or bare) of power supply cord under green external ground conductor screw (A). Tighten screw.

Remove center terminal block screw (B).

10

2. Connect neutral wire

Direct Wire Connection
B C

Connect neutral wire (white or center) (C) of power supply cord under center terminal block screw (B). Tighten screw.
3. Connect remaining wires

Direct wire strain relief
1. Attach direct wire strain relief

Connect remaining wires under outer terminal block screws.

Tighten screws. Finally, reinsert tab of terminal block cover

A

into slot of dryer rear panel. Secure cover with hold-down

screw. Now, go to "Connect Outlet Hose."

B

C

Unscrew the removable conduit connector (A) and any screws from a 3/4" (19 mm) UL-listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief (C) through the hole below the terminal block opening (B). Reaching inside the terminal block opening, screw the removable conduit connector (A) onto the strain relief threads, and tighten securely.

11

2. Attach direct wire cable to strain relief

2. Prepare to connect neutral ground wire and neutral wire

E B
A

Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.
If your wiring looks like this:
4-wire direct connection: Go to "4-Wire Direct Wire Connection."

3-wire direct connection: Go to "3-Wire Direct Wire Connection."

4-Wire Direct Wire Connection
IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit 3-wire connections.
1. Prepare your 4-wire cable for direct connection

31 (89

/2m" m)

(251m" m)

Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A).
3. Connect neutral ground wire and neutral wire
B E
C
Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of terminal block (B). Squeeze hooked ends together and tighten screw.

(127

5" mm)

4. Connect ground wire

Direct wire cable must have 5 ft. (1.52 m) of extra length so

dryer may be moved if needed. A

Strip 5" (127 mm) of outer covering from end of cable,

leaving bare ground wire at 5" (127 mm). Cut 11/2" (38 mm)

from remaining 3 wires. Strip insulation back 1" (25 mm).

F

Shape ends of wires into hooks.

Connect ground wire (green or bare) (F) of direct wire cable under green external ground conductor screw (A). Tighten screw.
12

5. Connect remaining wires

3. Connect neutral wire
B C

Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to "Connect Outlet Hose."
3-Wire Direct Wire Connection
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
1. Prepare your 3-wire cable for direct connection
(251m" m)

Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B), hook facing right. Squeeze hooked end together. Tighten screw.
4. Connect remaining wires

(893m½m" )
Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed. Strip 31/2" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape wire ends into hooks.
2. Remove center screw

Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to "Connect Outlet Hose."
Optional External Ground for 3-Wire Connection (Power Supply Cord Shown)
IMPORTANT: You must verify with a qualified electrician that this grounding method is acceptable before connecting.
1. Prepare to connect neutral ground wire and neutral wire

E B
B

Remove center terminal block screw (B).

A
Install the correct strain relief for your electrical connection method, as shown on page 8 or 11. Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A).
13

2. Connect neutral ground wire and neutral wire
B E C

Connect Outlet Hose 1. Attach hose

Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center, terminal block screw (B). Tighten screw.
3. Connect remaining wires

Attach the goose-neck fitting of the provided 6 ft. (1829 mm) drain hose to the drain valve at the bottom of dryer back panel. Screw on coupling by hand until it is seated on valve connector.
2. Tighten coupling

Place ends of remaining wires under outer terminal block screws. Tighten screws.
4. Connect external ground wire

Using channel locks, tighten the coupling an additional two-thirds turn.
NOTE: Do not over tighten. Damage to the coupling can result.

3. Secure drain hose system

Laundry Tub

Standpipe

Wall

4.5"

4.5"

4.5"

(114 mm)

(114 mm)

(114 mm)

A

G

Connect a separate copper ground wire (G) under the green external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to "Connect Outlet Hose."

Secure drain hose to laundry tub leg, drain standpipe, or inlet hoses for wall standpipe with cable tie.

14

Level Dryer 1. Level dryer
Place level here

Check levelness of dryer from side to side. Repeat from front to back.
NOTE: The dryer must be level for the moisture-sensing system to operate correctly. If forward slope of dryer is greater than 1" (25 mm), water could run out from front of filter.

3. Plug into a grounded 3 prong outlet

Not Level

LEVEL

2. Adjust leveling legs

Not Level

4. Check for leaks

If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once dryer is level, make sure all four legs are snug against the floor and dryer does not rock.
While running the first cycle, check that there are no leaks from the drain hose.
15

Complete Installation Checklist
q Check that all parts are now installed. If there is an extra part, go back through steps to see what was skipped.
q Check that dryer is level. See "Level Dryer." q Check that you have all of your tools. q Dispose of/recycle all packaging materials. q Check dryer's final location. q Remove film on console and any tape remaining on dryer. q Wipe dryer drum interior thoroughly with a damp cloth to
remove any dust.
q Read "Dryer Use" in your Use and Care Guide. q For power supply cord installation, plug into a grounded
outlet. For direct wire installation, turn on Power.
qSelect a Timed Dry heated cycle and start dryer.
If dryer will not start, check the following: · Controls are set in a running or ON position. · Start button has been pushed firmly. · Dryer is plugged into an outlet and/or electrical supply. · Household fuse is intact and tight or circuit breaker has not tripped. · Dryer door is closed.
This dryer automatically runs an installation diagnostic routine at the start of its first cycle.
NOTE: You may notice an odor when dryer is first heated. This odor is common when heating element is first used. The odor will go away.

Door Reversal (optional)
The following instructions are for models with a round and square-shaped doors.
Tools needed:

Min. 8" long TORX T25®  screwdriver

#2 Phillips screwdriver

Reverse door swing curved glass ­ single handle

1. Remove door from dryer

IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from the dryer door before proceeding.
Using a T25® screwdriver, remove the 4 screws securing the door hinge to the dryer and lift up and out to remove the door. Place the door on a soft towel or other non-scratch surface. Reinstall the 4 screws in the holes.

® TORX and T25 are registered trademarks of Acument Intellectual Properties, LLC.
16

2. Move the door strike

4. Remove outer window assembly
from trim ring

Using a T25® screwdriver, remove the 2 screws securing the door strike to the door frame of the dryer. Rotate the strike 180° and attach to the opposite side of dryer door frame as shown.
3. Remove inner door from outer door

Fig. A

Fig. B
Using a Phillips screwdriver, remove the 2 screws from the outer window retainer and rotate the outer window assembly clockwise until the square notches line up with the 4 tabs on the trim ring indicated with arrows in figure A above. Then lift out the outer window and retainer up and off the trim ring and set aside (B).
Position the door with the inside of the door facing up. Using a Phillips screwdriver, remove the 10 screws securing the inner door to the outer door. Lift off the inner door and set aside.

17

5. Reverse outer window assembly
Handle

6. Rotate and reassemble outer window
assembly to trim ring
Bottom of door

Notches Fig. A

Fig. A

Handle Fig. B
Using a Phillips screwdriver, remove the 4 screws from the outer window retainer and lift off the trim ring from the window (A). Rotate trim ring 180° and secure with the 4 screws removed earlier (B).

Fig. B
With the edge with 2 notches at the top, align the notches on the outer window assembly with the tabs on the trim ring and lower into place as shown in figure A. Rotate the outer window assembly counterclockwise to lock tabs into place (figure B). Using a Phillips screwdriver, secure with 2 screws removed earlier. IMPORTANT: Do not overtighten.

18

7. Remove hinge and latch
Latch

9. Reinstall inner door assembly
Bottom of door

Hinge

Using a T25® screwdriver, remove the 3 screws securing the latch plate and latch backing plate and the 5 screws holding the hinge assembly in place.
8. R einstall hinge and latch on
opposite sides

Position the door with the inside of the door facing up. Using a Phillips screwdriver, reinstall the 10 screws securing the inner door to the outer door.
10. Reinstall door on dryer

Using a T25® screwdriver, reinstall the latch plate, latch backing plate, and hinge assembly on the opposite sides from which they were removed.

Using a T25® screwdriver, remove the 4 screws on the dryer. Insert the tabs on the hinge into the mounting slot and slide down to engage the top tab. Secure in place with the 4 screws removed earlier.

19

Reverse door swing curved glass ­ double handle

1. Remove door from dryer

3. Remove inner door from outer door

IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from the dryer door before proceeding. Using a T25® screwdriver, remove the 4 screws securing the door hinge to the dryer and lift up and out to remove the door. Place the door on a soft towel or other non-scratch surface. Reinstall the 4 screws in the holes.
2. Move the door strike

Position the door with the inside of the door facing up. Using a Phillips screwdriver, remove the 10 screws securing the inner door to the outer door. Lift off the inner door and set aside.
4. Remove hinge and latch
Latch

Using a T25® screwdriver, remove the 2 screws securing the door strike to the door frame of the dryer. Rotate the strike 180° and attach to the opposite side of dryer door frame as shown.

Hinge
Using a T25® screwdriver, remove the 3 screws securing the latch plate and latch backing plate and the 5 screws holding the hinge assembly in place.

20

5. R einstall hinge and latch on
opposite sides

7. Reinstall door on dryer

Using a T25® screwdriver, reinstall the latch plate and latch backing plate with the 3 screws removed earlier and the hinge assembly with the 5 screws on the opposite sides from which they were removed.
6. Reinstall inner door assembly
Bottom of door

Using a T25® screwdriver, remove the 4 screws on the dryer. Insert the tabs on the hinge into the mounting slot and slide down to engage the top tab. Secure in place with the 4 screws removed earlier.
Reverse door swing flat glass ­ single handle
1. Remove door from dryer

Position the door with the inside of the door facing up. Using a Phillips screwdriver, reinstall the 10 screws securing the inner door to the outer door.

IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from the dryer door before proceeding.
Using a T25® screwdriver, remove the 4 screws securing the door hinge to the dryer and lift up and out to remove the door. Place the door on a soft towel or other non-scratch surface. Reinstall the 4 screws in the holes.

21

2. Move the door strike

4. Remove outer window assembly
from trim ring

Using a T25® screwdriver, remove the 2 screws securing the door strike to the door frame of the dryer. Rotate the strike 180° and attach to the opposite side of dryer door frame as shown.
3. Remove inner door from outer door

Fig. A

Fig. B
Using a Phillips screwdriver, remove the 2 screws from the outer window retainer and rotate the outer window assembly clockwise until the square notches line up with the 4 tabs on the trim ring indicated with arrows in figure A above. Then lift out the outer window and retainer up and off the trim ring and set aside (B).
Position the door with the inside of the door facing up. Using a Phillips screwdriver, remove the 10 screws securing the inner door to the outer door. Lift off the inner door and set aside.

22

5. Reverse outer window assembly
Handle

6. Rotate and reassemble outer window
assembly to trim ring
Bottom of door

Fig. A

Notches

Fig. A

Handle Fig. B
Using a Phillips screwdriver, remove the 4 screws from the outer window retainer and lift off the trim ring off the window (A). Rotate trim ring 180° and secure with the 4 screws removed earlier (B).

Fig. B
With the edge with 2 notches at the top, align the notches on the outer window assembly with the tabs on the trim ring and lower into place as shown in figure A. Rotate the outer window assembly counterclockwise to lock tabs into place (figure B). Using a Phillips screwdriver, secure with 2 screws removed earlier.
IMPORTANT: Do not overtighten.

23

7. Remove hinge and latch
Latch

9. Reinstall inner door assembly
Bottom of door

Hinge

Using a T25® screwdriver, remove the 3 screws securing the latch plate and latch backing plate and the 5 screws holding the hinge assembly in place.
8. R einstall hinge and latch on
opposite sides

Position the door with the inside of the door facing up. Reinstall the 10 screws securing the inner door to the outer door.
10. Reinstall door on dryer

Using a T25® screwdriver, reinstall the latch plate, latch backing plate, and hinge assembly on the opposite sides from which they were removed.

Using a T25® screwdriver, remove the 4 screws on the dryer. Insert the tabs on the hinge into the mounting slot and slide down to engage the top tab. Secure in place with the 4 T25® screws removed earlier.

24

Reverse door swing flat glass ­ double handle

1. Remove door from dryer

3. Remove inner door from outer door

IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from the dryer door before proceeding. Using a T25® screwdriver, remove the 4 screws securing the door hinge to the dryer and lift up and out to remove the door. Place the door on a soft towel or other non-scratch surface. Reinstall the 4 screws in the holes.
2. Move the door strike

Position the door with the inside of the door facing up. Using a Phillips screwdriver, remove the 10 screws securing the inner door to the outer door. Lift off the inner door and set aside.
4. Remove hinge and latch
Latch

Using a T25® screwdriver, remove the 2 screws securing the door strike to the door frame of the dryer. Rotate the strike 180° and attach to the opposite side of dryer door frame as shown.

Hinge
Using a T25® screwdriver, remove the 3 screws securing the latch plate and latch backing plate and the 5 screws holding the hinge assembly in place.

25

5. R einstall hinge and latch on
opposite sides

7. Reinstall door on dryer

Using a T25® screwdriver, reinstall the latch plate and latch backing plate with the 3 TORX® screws removed earlier and the hinge assembly with the 5 screws on the opposite sides from which they were removed.
6. Reinstall inner door assembly
Bottom of door

Using a T25® screwdriver, remove the 4 screws on the dryer. Insert the tabs on the hinge into the mounting slot and slide down to engage the top tab. Secure in place with the 4 screws removed earlier.
Troubleshooting
See the Use and Care Guide or visit our website and reference Frequently Asked Questions to possibly avoid the cost of a service call.

Position the door with the inside of the door facing up. Reinstall the 10 screws securing the inner door to the outer door.
26

Sécurité de la sécheuse
Certaines pièces internes sont intentionnellement non reliées à la terre et peuvent présenter un risque de choc électrique uniquement lors d'une intervention de dépannage. Personnel d'entretien - Ne pas toucher le support du thermostat lorsque l'appareil est sous tension.
27

Exigences d'installation
OUTILLAGE ET PIÈCES Rassembler les outils et composants nécessaires avant d'entreprendre l'installation. Outillage nécessaire :

Tournevis à lame plate

Tournevis Phillips n° 2

Pièces fournies:

Pieds de nivellement (4)

Tuyau flexible de vidange de 6 pi (1829 mm) avec raccords

Pince à dénuder (pour les installations à raccordement direct)

Pince multiprise

Tourne-écrou de 1/4" et 5/16" (recommandé)

Clé à molette avec ouverture jusqu'à 1" (25 mm) ou clé à douille à tête hexagonale

Couteau

Mètre-ruban

Serre-câbles (2)
Le sachet de pièces se trouve dans le tambour de la sécheuse. Vérifier que toutes les pièces sont présentes.
REMARQUE : Ne pas utiliser les pieds de nivellement si la sécheuse doit être installée sur un piédestal ou un ensemble superposé.
En cas d'utilisation d'un câble d'alimentation électrique : Utiliser un ensemble de câble d'alimentation électrique homologué UL marqué compatible avec les sécheuses. L'ensemble doit contenir :
Un câble d'alimentation électrique homologué UL de 30 ampères, 120/240 volts minimum. Le cordon doit être de type SRD ou SRDT et mesurer au moins 4 pi (1,22 m) de long. Les fils raccordés à la sécheuse doivent se terminer par des cosses rondes ou à fourche à pointes relevées.
Un serre-câble (homologation UL).
Accessoires supplémentaires : (Non fourni avec la sécheuse) Se référer au Guide d'utilisation et d'entretien pour des renseignements sur les accessoires disponibles pour la sécheuse.

Niveau

Pince

28

Exigences d'emplacement
Vérifier les spécifications des codes. Certains codes limitent ou interdisent l'installation des sécheuses dans un garage, un placard, une maison mobile ou une chambre à coucher. Contacter l'inspecteur en bâtiments local.

DIMENSIONS DE LA SÉCHEUSE

Vue de face :

27" (686 mm)

383/4" Min. (984 mm)
39" Max. (990 mm)

Vue latérale :

51 " min. (1314 mm)
31 " min. (806 mm)

Il vous faudra :
Un circuit séparé de 30 ampères.
Si on utilise un cordon d'alimentation, une prise électrique avec liaison à la terre située à moins de 2 pi (610 mm) de l'un des côtés de la sécheuse. Voir "Spécifications électriques".
Le plancher doit supporter le poids de la sécheuse de 200 lb (90,7 kg). Il faut également prendre en compte le poids des appareils ménagers voisins.
Un plancher de niveau ayant une pente maximale de 1" (25 mm) sous l'ensemble de la sécheuse. Si la pente vers l'avant est supérieure à 1" (25 mm), de l'eau pourrait s'échapper de l'avant du filtre. Installer un ensemble de pieds d'extension pour sécheuse, référence 279810. Si la sécheuse n'est pas d'aplomb, le linge peut ne pas culbuter convenablement, et les programmes automatiques commandés par détecteur peuvent ne pas fonctionner correctement.
Pour l'installation dans un garage, placer la sécheuse à au moins 18" (460 mm) au-dessus du sol. En cas d'utilisation d'un piédestal, il faudra 18" (460 mm) jusqu'au fond de la sécheuse.
La sécheuse ne doit pas être installée ou remisée dans un endroit où elle sera exposée à l'eau et/ou aux intempéries.
IMPORTANT : Ne pas faire fonctionner, installer ou remiser la sécheuse dans un endroit où elle sera exposée à l'eau, aux intempéries ou à des températures inférieures à 40° F (4° C). Des températures inférieures pourraient empêcher l'arrêt de la sécheuse à la fin des programmes automatiques commandés par détecteur, et causer des durées prolongées de séchage.

Vue arrière :

REMARQUE : Laisser un dégagement derrière la sécheuse pour acheminer correctement le tuyau flexible de vidange et assurer une bonne ventilation par le ventilateur de refroidissement. Repousser la sécheuse aussi loin que possible et s'assurer que le tuyau de vidange n'est pas écrasé ou déformé.

61/2" (165 mm)

Cordon/câble d'alimentation électrique

Sortie d'eau

297/8"* (759 mm) Ventilateur de

refroidissement

131/2"

61/2"

(343 mm) (165 mm)

*Mesures approximatives

IMPORTANT : Ne pas bloquer le ventilateur de refroidissement; cela pourrait empêcher la sécheuse de fonctionner correctement.

29

Espacement pour une installation dans un encastrement ou dans un placard Les dimensions indiquées correspondent à l'espacement minimal permis.
Prévoir davantage d'espace pour faciliter l'installation et l'entretien.
Un espace supplémentaire peut être requis pour le mur, la porte, le plancher, les moulures et le système de vidange.
Un espace supplémentaire doit être envisagé de tous les côtés de la sécheuse afin de réduire le transfert de bruit.
Pour installation dans un placard avec porte, on doit prévoir des ouvertures minimums d'entrée d'air en haut et en bas de la porte. Les portes à claire-voie offrant des ouvertures équivalentes de passage de l'air sont acceptables.
Il faut aussi prendre en compte l'espace requis entre les appareils voisins.
Distances de dégagement recommandées pour l'installation (sécheuse seulement) :

Système de vidange
Le système de vidange peut être installé à l'aide d'un conduit d'évacuation au plancher, un tuyau rigide de rejet à l'égout mural, un tuyau rigide de rejet à l'égout au plancher ou un évier de buanderie. Sélectionner la méthode à utiliser.
IMPORTANT : Pour éviter un effet de siphon, pas plus de 4,5" (114 mm) de tuyau de vidange ne devrait être inséré à l'intérieur de la canalisation d'évacuation. Toujours immobiliser le tuyau de vidange avec un serre-câble.
Système de vidange avec tuyau de rejet à l'égout au plancher

4.,5" (114 mm)

max, 54" (1372 mm)
min, 30" (762 mm)

0" - 5"* (0 mm - 127 mm)

18" min. (457 mm)

3"
(76 mm) 48 in.2 min. (310 cm2)

24 in.2 min. (155 cm2) 3" (76 mm)

1" (25 mm)

1" (25 mm)

*REMARQUE : Un espacement de 0" ( 0 mm) est permis derrière la sécheuse pour empêcher le tuyau de se déformer ou de se coincer.

Sans piédestal

4.,5" (114 mm)

max, 69" (1753 mm)
min, 30" (762 mm)

Avec piédestal assorti de 15"
Diamètre minimal pour un tuyau de rejet à l'égout : 2" (51 mm). Capacité minimale d'écoulement : 17 gal (64 L) par minute. Un ensemble adaptateur de tuyau de rejet à l'égout de 1/4" (6 mm) à 1" (25 mm) de diamètre est disponible. Le tuyau vertical de rejet à l'égout doit avoir une hauteur d'au moins 30" (762 mm); ne pas l'installer à une hauteur supérieure à 54" (1,37 m) du bas de la sécheuse. IMPORTANT : Seuls 4,5" (114 mm) de tuyau de vidange doivent se trouver à l'intérieur du tuyau de rejet à l'égout. Ne pas introduire toute la longueur du tuyau en surplus dans le tuyau rigide.
Système de vidange avec tuyau de rejet à l'égout mural

Installation dans une résidence mobile ­ exigences supplémentaires :
Cette sécheuse peut être installée dans une maison mobile. L'installation doit se conformer aux critères de la Manufactured Home Construction and Safety Standard, Titre 24 CFR, partie 3280 (anciennement Federal Standard for Mobile Home Construction and Safety, Titre 24 HUD, partie 280) ou de la Norme CAN/CSA-Z240MH.

4,5" (114 mm)
Voir les exigences pour le système de vidange avec tuyau de rejet à l'égout au plancher.

30

Système de vidange dans un évier de buanderie

4.,5" (114 mm)

max, 54" (1372 mm)
min, 30" (762 mm)

Capacité minimale : 20 gal. (76 L). Le sommet de l'évier de buanderie doit se trouver à au moins 30" (762 mm) du plancher; ne pas l'installer à une hauteur supérieure à 54" (1,37 m) du fond de la sécheuse.
IMPORTANT : Seuls 4,5" (114 mm) de tuyau flexible de vidange doivent se trouver sur le côté de l'évier de buanderie. Ne pas mettre le tuyau de vidange dans le fond de l'évier de buanderie.
Système de vidange au sol

 S'assurer que le raccordement électrique est adéquat et conforme au Code canadien de l'électricité, C22.1 ­ dernière édition, et à tous les codes locaux en vigueur. Pour obtenir un exemplaire des normes des codes ci-dessus, contacter : Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
 L'appareil doit être alimenté uniquement par un circuit monophasé de 120/240 V CA seulement, 60 Hz à 4 fils, sur un circuit séparé de 30 ampères, fusionné aux deux extrémités de la ligne. On recommande d'utiliser un fusible ou un disjoncteur temporisé. On recommande également que cet appareil soit alimenté par un circuit indépendant.
 Cette sécheuse est équipée d'un cordon d'alimentation homologué par la CSA International à introduire dans une prise murale standard 14-30R. Le cordon mesure 5 pi (1,52 m). Veiller à ce que la prise murale se trouve à proximité de l'emplacement définitif de la sécheuse.
Prise murale à 4 fils (14-30R)
 Ne pas utiliser de rallonge. Lorsqu'on utilise un cordon d'alimentation de rechange, il est recommandé d'utiliser le cordon d'alimentation de rechange, pièce n° 8579325. Pour plus de renseignements, consulter les numéros de service indiqués à la section "Assistance ou service" du Guide d'utilisation et d'entretien.

Éliminer le coude en U à l'extrémité du tuyau de vidange en le coupant à ras pour le système de vidange au sol illustré dans l'image ci-dessus. REMARQUE : Couper le tuyau de sorte qu'il n'entre pas plus profondément que 4,5" (114 mm) dans l'évacuation du plancher pour éviter tout phénomène de siphonnage.
Sécheuse électrique raccordement à l'alimentation électrique - canada seulement
Spécifications Électriques

INSTRUCTIONS DE LIAISON À LA TERRE
Pour une sécheuse reliée à la terre et connectée par un cordon :
Cette sécheuse doit être reliée à la terre. En cas de mauvais fonctionnement ou de panne, la liaison à la terre réduira le risque de choc électrique en offrant au courant électrique un acheminement d'évacuation de moindre résistance. Cette sécheuse est alimentée par un cordon électrique comportant un conducteur relié à la terre et une che de branchement munie d'une broche de liaison à la terre. La che doit être branchée sur une prise appropriée qui est bien installée et reliée à la terre conformément à tous les codes et règlements locaux.
AVERTISSEMENT : Le raccordement incorrect de
cet appareil au conducteur de liaison à la terre peut susciter un risque de choc électrique. En cas de doute quant à la qualité de liaison à la terre de la sécheuse, consulter un électricien ou un technicien ou un personnel quali é. Ne pas modi er la che de branchement fournie avec la sécheuse; si la che ne correspond pas à la con guration de la prise de courant, demander à un électricien quali é d'installer une prise de courant appropriée.
CONSERVEZ CES INSTRUCTIONS

C'est à l'utilisateur qu'incombe la responsabilité de :
 Contacter un électricien qualifié.
31

Installation des pieds de nivellement

Connexion du tuyau de sortie 1. Fixation du tuyau

1. Préparer la sécheuse pour les pieds
de nivellement

Fixer le raccord col-de-cygne du tuyau de vidange de 6 pieds (1829 mm) fourni à l'électrovanne de vidange en bas du panneau arrière de la sécheuse. Visser la bague à la main jusqu'à ce qu'elle repose sur le raccord de l'électrovanne.
2. Serrer la bague

Pour ne pas endommager le plancher, utiliser une grande pièce de carton de l'emballage de la sécheuse; la placer sous tout le bord arrière de la sécheuse. Saisir fermement la sécheuse par la caisse (non par le panneau de commande) et incliner soigneusement la sécheuse sur le carton.
REMARQUE : De l'eau restante issue des tests en usine peut s'évacuer si la sécheuse est étendue sur le côté.
2. Visser dans les pieds de nivellement

Terminer le serrage de la bague de deux tiers de tour supplémentaire avec la pince multiprise.
REMARQUE : Ne pas serrer excessivement. Le raccord risque d'être endommagé.

3. Fixer le tuyau de vidange

Évier de buanderie

Tuyau rigide de rejet Mur à l'égout

À l'aide d'une clé et d'un mètre-ruban, visser les pieds dans les trous pour pieds de nivellement jusqu'à ce que le bas de chaque pied se trouve à environ 1/2" (13 mm) depuis le bas de la sécheuse.
À présent, redresser la sécheuse et la placer sur ses pieds. Faire glisser la sécheuse jusqu'à ce qu'elle se trouve à proximité de son emplacement final.

4,.5" (114 mm)

4,.5" (114 mm)

4,.5" (114 mm)

Fixer le tuyau de vidange avec le serre-câble au pied de l'évier de buanderie, au tuyau rigide de rejet à l'égout ou aux tuyaux d'arrivée d'eau pour le tuyau de rejet à l'égout mural rigide.

32

Réglage de l'aplomb de la sécheuse 1. Réglage de l'aplomb de la sécheuse
PPllaacceer le vneivl ehaeureici

Vérifier l'aplomb de la sécheuse d'un côté à l'autre. Répéter l'opération de l'avant vers l'arrière.
REMARQUE : La sécheuse doit être d'aplomb pour que le système de détection d'humidité fonctionne correctement. Si la pente vers l'avant est supérieure à 1" (25 mm), de l'eau pourrait s'échapper de l'avant du filtre.

3. Brancher l'appareil sur une prise à
3 alvéoles reliée à la terre

Pas d'aplomb

D'APLOMB

Pas d'aplomb

2. Ajuster les pieds de nivellement

4. Recherche de fuites

Si la sécheuse n'est pas d'aplomb, la relever à l'aide d'un bloc de bois, utiliser une clé pour ajuster les pieds vers le haut ou vers le bas, et vérifier à nouveau si elle est d'aplomb. Une fois la sécheuse d'aplomb, s'assurer que les quatre pieds sont en contact ferme avec le plancher et que la sécheuse ne tangue pas.
Pendant l'exécution du premier programme, vérifier l'absence de fuite sur le tuyau de vidange.

33

Achever l'installation liste de vérification
q Vérifier que toutes les pièces sont maintenant installées. S'il reste une pièce, passer en revue les différentes étapes pour découvrir laquelle aurait été oubliée.
q Vérifier que la sécheuse est d'aplomb. Voir "Réglage de l'aplomb de la sécheuse".
q Vérifier la présence de tous les outils. q Éliminer/recycler les matériaux d'emballage. q Vérifier l'emplacement définitif de la sécheuse. q Retirer la pellicule sur le panneau de commande et tout
ruban adhésif resté sur la sécheuse.
q Essuyer soigneusement l'intérieur du tambour de la sécheuse avec un chiffon humide pour éliminer toute trace de poussière.
q Lire la section "Utilisation de la sécheuse" dans le Guide d'utilisation et d'entretien.
q Mettre l'appareil sous tension. qSélectionner un programme de séchage minuté avec chaleur
et mettre la sécheuse en marche.
Si la sécheuse ne démarre pas, vérifier ce qui suit : · Les commandes sont placées dans une position de fonctionnement ou sur "ON" (marche). · On a appuyé fermement sur la touche Start (mise en marche). · La sécheuse est branchée dans une prise et/ou l'alimentation électrique est branchée. · Les fusibles du domicile sont intacts et serrés; le disjoncteur n'est pas déclenché. · La porte de la sécheuse est fermée.
Cette sécheuse démarre automatiquement une procédure de diagnostic au début du premier programme.
REMARQUE : Il est possible que la sécheuse dégage une odeur lors du chauffage initial. Cette odeur est normale lorsque l'élément chauffant est utilisé pour la première fois. L'odeur disparaîtra.

Inversion de la porte (facultatif)
Les instructions suivantes correspondent aux modèles avec porte arrondie et carrée. Outils nécessaires :

Tournevis TORX® T25® de 8" min. de long.

Tournevis Phillips n° 2

Inversion du sens d'ouverture de la porte, modèle bombé verre incurvé ­ poignée unique

1. Retirer la porte de la sécheuse

IMPORTANT : Si l'on n'a pas encore retiré la pellicule protectrice de la sécheuse, la décoller de la porte de la sécheuse avant de continuer.
À l'aide d'un tournevis T25®, retirer les 4 vis fixant la charnière de porte à la sécheuse et soulever la porte pour la retirer. Placer la porte sur une serviette douce ou sur une surface lisse. Replacer les 4 vis dans les mêmes trous.

® TORX et T25 sont les marques de commerce déposées de Acument Intellectual Properties, LLC.
34

2. Déplacer la gâche de la porte

4. Retirer la garniture circulaire de
la partie externe du hublot

À l'aide d'un tournevis T25®, retirer les 2 vis fixant la gâche de la porte au châssis de la porte de la sécheuse. Faire pivoter la gâche de 180° et la fixer au côté opposé du châssis de la porte de la sécheuse, tel qu'indiqué.
3. Dégager la porte interne de la porte
externe

fig. A

fig. B
À l'aide d'un tournevis Phillips, retirer les 2 vis du support de la partie externe du hublot et faire pivoter la partie externe du hublot dans le sens horaire jusqu'à ce que les indentations carrées soient alignées avec les 4 onglets de la garniture circulaire aux emplacements indiqués par les flèches dans l'illustration A ci-dessus. Soulever ensuite la partie externe du hublot et le support, et les dégager de la garniture circulaire les mettre de côté (B).
Positionner la porte de façon à ce que l'intérieur de la porte soit orienté vers le haut. À l'aide d'un tournevis Phillips, retirer les 10 vis fixant la porte interne à la porte externe. Soulever la porte interne pour la dégager et la mettre de côté.

35

5. Inversion du sens de la partie
externe du hublot
Poignée

6. Faire pivoter la partie externe
du hublot et la réinstaller sur la garniture circulaire
Bas de la porte

fig. A

Encoches

fig. A

Poignée fig. B
À l'aide d'un tournevis Phillips, retirer les 4 vis du support de la partie externe du hublot et extraire l'anneau de garniture de la fenêtre (A). Faire pivoter l'anneau de garniture à 180° et fixer les 4 vis retirées à l'étape précédente (B).

fig. B
Tout en plaçant le bord comportant les 2 indentations au sommet, aligner les indentations de la partie externe du hublot avec les onglets de la garniture circulaire et abaisser le tout pour la mise en place tel qu'illustré à la figure A. Faire pivoter la partie externe du hublot dans le sens antihoraire pour emboîter les onglets (figure B). Avec un tournevis Phillips, visser les 2 vis précédemment retirées. IMPORTANT : Ne pas serrer excessivement.

36

7. Retirer la charnière et le loquet
Loquet

9. Réinstaller la porte interne
Bas de la porte

Charnière

À l'aide d'un tournevis T25®, retirer les 3 vis fixant la plaque de protection du loquet et la plaque de support du loquet; retirer aussi les 5 vis maintenant la charnière en place.
8. Réinstaller la charnière et le loquet
sur chaque côté

Positionner la porte de façon à ce que l'intérieur de la porte soit orienté vers le haut. Réinstaller les 10 vis fixant la porte interne à la porte externe à l'aide d'un tournevis Phillips.
10. Réinstaller la porte sur la sécheuse

À l'aide d'un tournevis T25®, réinstaller la plaque de protection du loquet, la plaque de support du loquet et la charnière sur les côtés dont elles ont été respectivement retirées.

À l'aide d'un tournevis T25®, retirer les 4 vis de la sécheuse. Insérer les onglets sur la charnière dans l'encoche de montage et les faire glisser vers le bas pour engager l'onglet supérieur. Fixer avec les 4 vis précédemment retirées.

37

Inversion du sens d'ouverture de la porte, modèle bombé verre incurvé ­ poignée double

1. Retirer la porte de la sécheuse

3. Dégager la porte interne de la porte
externe

IMPORTANT : Si l'on n'a pas encore retiré la pellicule protectrice de la sécheuse, la décoller de la porte de la sécheuse avant de continuer.
À l'aide d'un tournevis T25®, retirer les 4 vis fixant la charnière de porte à la sécheuse et soulever la porte pour la retirer. Placer la porte sur une serviette douce ou sur une surface lisse. Replacer les 4 vis dans les mêmes trous.
2. Déplacer la gâche de la porte

Positionner la porte de façon à ce que l'intérieur de la porte soit orienté vers le haut. À l'aide d'un tournevis Phillips, retirer les 10 vis fixant la porte interne à la porte externe. Soulever la porte interne pour la dégager et la mettre de côté.
4. Retirer la charnière et le loquet
Loquet

À l'aide d'un tournevis T25®, retirer les 2 vis fixant la gâche de la porte au châssis de la porte de la sécheuse. Faire pivoter la gâche de 180° et la fixer au côté opposé du châssis de la porte de la sécheuse, tel qu'indiqué.

Charnière

À l'aide d'un tournevis T25®, retirer les 3 vis fixant la plaque de protection du loquet et la plaque de support du loquet; retirer aussi les 5 vis maintenant la charnière en place.

38

5. Réinstaller la charnière et le loquet
sur chaque côté

7. Réinstaller la porte sur la sécheuse

Au moyen d'un tournevis T25®, remonter la plaque de protection du loquet et la plaque de support du loquet avec les 3 vis ôtées précédemment, ainsi que la charnière avec les 5 vis, du côté opposé à celui duquel elles ont été enlevées.
6. Réinstaller la porte interne
Bas de la porte

À l'aide d'un tournevis T25®, retirer les 4 vis de la sécheuse. Insérer les onglets sur la charnière dans l'encoche de montage et les faire glisser vers le bas pour engager l'onglet supérieur. Fixer avec les 4 vis précédemment retirées.
Inversion du sens d'ouverture de la porte, modèle bombé à verre plat ­ poignée unique
1. Retirer la porte de la sécheuse

Positionner la porte de façon à ce que l'intérieur de la porte soit orienté vers le haut. Réinstaller les 10 vis fixant la porte interne à la porte externe à l'aide d'un tournevis Phillips.

IMPORTANT : Si l'on n'a pas encore retiré la pellicule protectrice de la sécheuse, la décoller de la porte de la sécheuse avant de continuer.
À l'aide d'un tournevis T25®, retirer les 4 vis fixant la charnière de porte à la sécheuse et soulever la porte pour la retirer. Placer la porte sur une serviette douce ou sur une surface lisse. Replacer les 4 vis dans les mêmes trous.

39

2. Déplacer la gâche de la porte

4. Retirer la garniture circulaire
de la partie externe du hublot

À l'aide d'un tournevis T25®, retirer les 2 vis fixant la gâche de la porte au châssis de la porte de la sécheuse. Faire pivoter la gâche de 180° et la fixer au côté opposé du châssis de la porte de la sécheuse, tel qu'indiqué.
3. Dégager la porte interne de la porte
externe

fig. A

fig. B
À l'aide d'un tournevis Phillips, retirer les 2 vis du support de la partie externe du hublot et faire pivoter la partie externe du hublot dans le sens horaire jusqu'à ce que les indentations carrées soient alignées avec les 4 onglets de la garniture circulaire aux emplacements indiqués par les flèches dans l'illustration A ci-dessus. Soulever ensuite la partie externe du hublot et le support, et les dégager de la garniture circulaire - les mettre de côté (B).
Positionner la porte de façon à ce que l'intérieur de la porte soit orienté vers le haut. À l'aide d'un tournevis Phillips, retirer les 10 vis fixant la porte interne à la porte externe. Soulever la porte interne pour la dégager et la mettre de côté.

40

5. Inversion du sens de la partie
externe du hublot
Poignée

6. Faire pivoter la partie externe du
hublot et la réinstaller sur la garniture circulaire
Bas de la porte

fig. A

Encoches

fig. A

Poignée
fig. B
À l'aide d'un tournevis Phillips, retirer les 4 vis du support de la partie externe du hublot et extraire l'anneau de garniture de la fenêtre (A). Faire pivoter l'anneau de garniture à 180° et fixer les 4 vis retirées à l'étape précédente (B).

fig. B
Tout en plaçant le bord comportant les 2 indentations au sommet, aligner les indentations de la partie externe du hublot avec les onglets de la garniture circulaire et abaisser le tout pour la mise en place tel qu'illustré à la figure A. Faire pivoter la partie externe du hublot dans le sens antihoraire pour emboîter les onglets (figure B). Avec un tournevis Phillips, visser les 2 vis précédemment retirées.
IMPORTANT : Ne pas serrer excessivement.

41

7. Retirer la charnière et le loquet
Loquet

9. Réinstaller la porte interne
Bas de la porte

Charnière

À l'aide d'un tournevis T25®, retirer les 3 vis fixant la plaque de protection du loquet et la plaque de support du loquet; retirer aussi les 5 vis maintenant la charnière en place.
8. Réinstaller la charnière et le loquet
sur chaque côté

Positionner la porte de façon à ce que l'intérieur de la porte soit orienté vers le haut. Réinstaller les 10 vis fixant la porte interne à la porte externe.
10. Réinstaller la porte
sur la sécheuse

À l'aide d'un tournevis T25®, réinstaller la plaque de protection du loquet, la plaque de support du loquet et la charnière sur les côtés opposés auxquels elles ont été respectivement retirées.

À l'aide d'un tournevis TORX T25®, retirer les 4 vis de la sécheuse. Insérer les onglets sur la charnière dans l'encoche de montage et les faire glisser vers le bas pour engager l'onglet supérieur. Fixer avec les 4 vis TORX T25® précédemment retirées.

42

Inversion du sens d'ouverture de la porte, modèle bombé à verre plat ­ poignée double

1. Retirer la porte de la sécheuse

3. Dégager la porte interne de la
porte externe

IMPORTANT : Si l'on n'a pas encore retiré la pellicule protectrice de la sécheuse, la décoller de la porte de la sécheuse avant de continuer. À l'aide d'un tournevis TORX T25®, retirer les 4 vis fixant la charnière de porte à la sécheuse et soulever la porte pour la retirer. Placer la porte sur une serviette douce ou sur une surface lisse. Replacer les 4 vis dans les mêmes trous.
2. Déplacer la gâche de la porte

Positionner la porte de façon à ce que l'intérieur de la porte soit orienté vers le haut. À l'aide d'un tournevis Phillips, retirer les 10 vis fixant la porte interne à la porte externe. Soulever la porte interne pour la dégager et la mettre de côté.
4. Retirer la charnière et le loquet
Loquet

À l'aide d'un tournevis TORX T25®, retirer les 2 vis fixant la gâche de la porte au châssis de la porte de la sécheuse. Faire pivoter la gâche de 180° et la fixer au côté opposé du châssis de la porte de la sécheuse, tel qu'indiqué.

Charnière

À l'aide d'un tournevis T25®, retirer les 3 vis fixant la plaque de protection du loquet et la plaque de support du loquet; retirer aussi les 5 vis maintenant la charnière en place.

43

5. Réinstaller la charnière et le loquet
sur chaque côté

7. Réinstaller la porte sur la sécheuse

Au moyen d'un tournevis T25®, remonter la plaque de protection du loquet et la plaque de support du loquet avec les 3 vis ôtées précédemment, ainsi que la charnière avec les 5 vis, du côté opposé à celui duquel elles ont été enlevées.
6. Réinstaller la porte interne
Bas de la porte

À l'aide d'un tournevis T25®, retirer les 4 vis de la sécheuse. Insérer les onglets sur la charnière dans l'encoche de montage et les faire glisser vers le bas pour engager l'onglet supérieur. Fixer avec les 4 vis T25® précédemment retirées.
Dépannage
Voir le Guide d'utilisation et d'entretien ou consulter notre site Web et la "Foire aux questions" pour tenter d'éviter le coût d'une intervention de réparation.

Positionner la porte de façon à ce que l'intérieur de la porte soit orienté vers le haut. Réinstaller les 10 vis fixant la porte interne à la porte externe.

W10777574B W10777575B - SP

©2015 Whirlpool. All rights reserved. Used under license in Canada.
©2015 Whirlpool. Tous droits réservés. Emploi sous licence au Canada.

11/15

