Majestic BE42 Royalton 42-Inch Radiant Wood Burning Fireplace
Majestic Royalton 42" Wood-Burning Fireplace BE42 – Flame Authority
3 mai 2023 — connection. If outside air duct has no bend, this dimension may be reduced as long as minimum clearances are met. * If interior chase will be drywalled,.
Specifications BE42 MODEL BE42 Please consult the manufacturer's installation manual for all details and requirements before making a final design layout decision. ROYALTON 42" Wood Fireplace FRONT WIDTH Actual Framing 47" 48" BACK WIDTH Actual Framing 29-3/4" 48" HEIGHT Actual Framing 39-1/2" 39-3/4" DEPTH Actual Framing 21-3/8" 21-1/2" FIREPLACE OPENING 42" x 21" 29-3/4" [756] 14-7/8" [378] 7-3/8" [187] 47" [1194] Top View 21-3/8" [543] 21" [533] 18-3/4" [476] 42" [1067] Front View 7-1/2" [191] 21" [533] 14-1/8" [359] 7-1/2" [191] Outside Air Gas Knockout 7-1/2" [191] 13-1/2" [476] Left Side View 17-7/8" [453] 9-1/4" [235] Additional information can be found online at www.majesticproducts.com or www.fireplaces.com 39-1/2" [1003] Gas Knockout 7-1/2" [191] 9-1/4" [235] Right Side View Specifications BE42 50° angle Combustible Object APPLIANCE LOCATION 17" [429] 37-1/4" [946] 52-1/4" [1327] 21-1/2" [546] 48" [1219] 73-7/8" [1876] Across a corner 48" [1219] 56" [1422] In an exterior chase or projecting into a garage 12" [305] min. 21-1/2" [546] 65-1/2" [1664] 48" [1219] minimum 48" [1219] As a room divider Along a wall 56" [1422] 48" [1219] 12" [305] min. 1/2" [13] all configurations 21-1/2" [546] MANTEL PROJECTIONS Combustible Wall Combustible Decorative Facing 7 ft [2134] minimum base of fireplace to ceiling 2 x 4 stud wall Standoffs Seal joint with non-combustible sealant 12" [305] 12" [305] minimum 1-1/2 [38] maximum 6" [152] minimum Non-combustible Decorative Facing such as: steel, iron, brick, tile, concrete, slate, glass or plasters Measured from top of fireplace opening MANTEL LEG/WALL PROJECTIONS 11-1/4" [286] FLUSH FRONT 42" [1067] 47" [1194] 12" [305] HEARTH EXTENSIONS 4" [102] minimum between bottom of fireplace opening and finished surface of hearth extension BRICK FRONT 4" [102] 39° angle 9-3/4" [248] 12" [305] 12" [305] 66" [1676] 42" [1067] 12" [305] 20" [508] FRAMING DIMENSIONS 2" [51] min air space clearance from chimney 15" [381] Header MUST NOT be notched! 39-3/4" [1010]** 48" [1219] 8" [203] 21-1/2" [546]* Extra space needed for outside air connection. If outside air duct has no * If interior chase will be drywalled, add thickness to this measurement. bend, this dimension may be reduced as long as minimum clearances are met ** Adjust header height for raised floor under fireplace CLEARANCES TO COMBUSTIBLES Storm Collar Roof Flashing (attic) (insulation) 2" [51] minimum Ceiling Firestop (roof) Shaded areas represents 2" [51] minimum air space clearance required around pipe. Attic Insulation Shield (ceiling) Offset/Return (secured with hanger straps (ceiling) Must have 2" [51] minimum clearance to header 0" to level of standoffs 48" [1219] 1/2" [13] to back & sides of appliance 0" to floor HEARTH EXTENSION CONSTRUCTION Continuous, non-combustible Fireplace sealant Opening Tile, stone or other noncombustible 1/2" [13] Micore Hearth Extension material (or equivalent insulation. See Installation Manual). 4" [102] minimum Floor constructed of wood or other combustible material 2" [51] of the Protective Metal Hearth Strip is required under the front of the fireplace PRODUCT LISTING CODES US UL 127 CAN ULC-S610 Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury. Additional information can be found online at www.majesticproducts.com Lakeville, MN Phone: (800) 927-6841 Web: www.majesticproducts.com MAJ/BE42_0817Adobe PDF Library 15.0 Adobe InDesign CC 2015 (Windows)