13-06131-010 AD RN Ignite v1182

Ignite

Grass Valley

ation Library | Grass Valley


File Info : application/pdf, 27 Pages, 902.57KB

PDF preview unavailable. Download the PDF instead.

13-06131-010-AD-Ignite Release Notes v11.8.2
IGNITE V11.8.2
LIVE PRODUCTION CONTROL SYSTEM
Release Notes
13-06131-010 AD 2022-06-01
www.grassvalley.com

Notices
Patent Information
This product may be protected by one or more patents. For further information, please visit: www.grassvalley.com/patents/
Copyright and Trademark Notice
Grass Valley®, GV® and the Grass Valley logo and/or any of the Grass Valley products listed
in this document are trademarks or registered trademarks of GVBB Holdings SARL, Grass Valley USA, LLC, or one of its affiliates or subsidiaries. All other intellectual property rights are owned by GVBB Holdings SARL, Grass Valley USA, LLC, or one of its affiliates or subsidiaries. All third party intellectual property rights (including logos or icons) remain the property of their respective owners. Copyright © 2019 - 2022 GVBB Holdings SARL and Grass Valley USA, LLC. All rights reserved. Specifications are subject to change without notice.
Terms and Conditions
Please read the following terms and conditions carefully. By using Ignite documentation, you agree to the following terms and conditions. Grass Valley hereby grants permission and license to owners of Ignite to use their product manuals for their own internal business use. Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose unless specifically authorized in writing by Grass Valley. A Grass Valley manual may have been revised to reflect changes made to the product during its manufacturing life. Thus, different versions of a manual may exist for any given product. Care should be taken to ensure that one obtains the proper manual version for a specific product serial number. Information in this document is subject to change without notice and does not represent a commitment on the part of Grass Valley. Warranty information is available from the Legal Terms and Conditions section of Grass Valley's website (www.grassvalley.com).

Title Revision

IGNITE V11.8.2 - Release Notes 2022-06-01, 14:15

ii

toc Table of Contents
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 New Features, Enhancements, and Bugs Fixed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
New Features and Enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Bug Fixes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation and Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Hardware Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Software Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
New Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Upgrade Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Configuration Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Open Source Software Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Apache . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Microsoft Public License . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 MIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Mozilla . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 NSubstitute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
1

IGNITE Release Notes
Introduction
This document describes compatibility, installation, and other information specific to Ignite Release 11.8.2 which is a maintenance release of the Ignite Live Production Control System.
+ + NNoottee For a current list of supported/controlled devices, contact an authorized Grass Valley reseller or contact Grass Valley sales directly.
New Features, Enhancements, and Bugs Fixed
This release adds the following enhancement(s) and corrects the following issue(s) that are separated out as follows.
· New Features and Enhancements, on page 1 · Bug Fixes, on page 1
New Features and Enhancements
· [[Ref. #IGN-11733] Ignite updated the Yamaha fader from 64 to 72 The Monitor Fader for Yamaha QL5 now increases from 64 to 72.
· [Ref. #IGN-11897] Ignite Snapshot tool now supports an entire snapshot The Ignite Snapshot tool is now able to import an entire snapshot with the configuration within the system tray. It is also able to restore from a snapshot within the Ignite installer.
Bug Fixes
· [Ref. #IGN-11768] The shared option disappearing issue has been corrected in Ignite Event Builder The shared option in Ignite Event Builder now works properly.
1

IGNITE Release Notes

· [Ref. #IGN-11980] Corrected potential problem with auto server logic The IQLayer error has been corrected.
· [Ref. #IGN-11922] Ensure current MOP Gateway selection not overwritten by synchronizer Synchronizer now never synchronizes the currently selected MOP server.
· [[Ref. #IGN-11990] Fixed an issue where the audible server countdown plays all the clips at the same time The server countdown timer now plays the clips correctly.

Compatibility

Hardware
This release requires hardware equipped with Windows 64-bit operating system.

Software

This Ignite Release 11.8.2 only functions with the Media Object Portal (MOP) and does not support the XMOS server from previous systems. If a customer is being upgraded from any version of Ignite prior to:

· 5.2.0.0, you must run the AlloyConversionUtilities found in the Ignite installation folder

· 5.1.1, you must convert the customer's TME & Macro library with the IgniteTMEProcessor found in the Ignite installation folder
Refer to the release matrix in Table 1

Category Protocol

Table 1. Release Matrix Application MOS MOP Server TME File Watcher Katalyst Automated Soft Panel (ASP) Ignite ActiveX

Model

Version 2.8.3 11.7 1.0.27 11.0.0 11.0.0 1.0.27

2

Compatibility Software

Category Newsroom Computer Systems
Audio Mixers
Audio Server Camera Robotics

Table 1. Release Matrix

Application ENPS Server

Model

Version 9.0.236

ENPS Client

9.0.236

iNEWS Server

7.2.0.28 / 4.6.0.5

iNEWS Client

7.2.0.28 / 4.6.0.5

iNEWS MOS Gateway

7.2.0.28 / 4.6.0.5

Dalet Galaxy (TME column

4.0

only)

Ross Inception

12.1.4.11185

Calrec

Sigma, Omega, Alpha, N/A and Zeta Audio Consoles

Calrec

Brio 36

1.1.8 build 205

Wheatstone

D5.1, D7, D8, D9, D10 (incl Dimension 1 & Dimension 3), D12, G3, G4, G5, G6 and G9 as well as the E Series (E4, E5 and E6)

D8, D10 and Series 4

Yamaha

LS9-16, LS9-32

1.35

Yamaha

QL1, QL5, CL1, CL3, CL5 V4.50

Lawo

6.4.0.11

10.2.0.16

Klotz

Vadis

1.2.5.006

SSL

C10HD

5.0/5

Studer

Studer 5.4.00 a3 or newer

Kula AV

6.3

Sony

Mini Disk -B5 and E11

N/A

360 Systems

DigiCart 2, 2+, E, EX

N/A

Enco

DadPro32

N/A

TASCAM

SS-R250N

v1.37

Cambotics Robotic Camera

N/A

System (Including the

SmartShell camera control

System )

Grass Valley SDC/HDC Ignite

N/A

Shotoku

T Remote Controller

Supports IP

Telemetrics

CPS-ST-S Controller

N/A

RCCP-1A Controller

PTZ

Protocol 1.01

VISCA

ARM: 3.0A FBGA: 5.6B USB: 5.2B ISP: 252

3

Category Graphics Device
Video Server Switcher

IGNITE Release Notes

Table 1. Release Matrix

Application Avid FXDeko

Model

Avid Deko 3000

Avid DekoMos

Chyron Duet

SD/LE/LEX, PCI/PCI+

Chyron HyperX (MOS)

ChyronAprisa

100, SSX

ChyronPrime

Harris Inscriber G3 (MOS)

Harris Inscriber G3 (nonMOS)

Vertigo/Xplay

Pixel Power

Clarity

VizRT

VizRT

WASP3D

ORAD

TD Control

Ross XPression

Avid AirPlay Avid AirSpeed Avid AirSpace BitCentral GrassValley M-Series GrassValley Turbo GrassValley K2 Grass Valley K2 Summit Grass Valley Profile,XP Leitch Omneon SQ Kayak Kalypso K-Frame
Kayenne Schooner Gv Director Kula Switcher Kahuna Switcher Sony Switcher

Precis
Nexio NX4000ITS Spectrum, MediaDeck SQ1200, SQ1800
S-Series, V-Series ( only support start from Ignite 10.1.0)

Version N/A N/A N/A N/A 8.0 (build 1558) N/A 3.5.12.300 N/A N/A
v6.0SP1 N/A 5.3.3 3.82 N/A v8.5 b4598
Configurable "Load and play" mode supported N/A N/A N/A N/A N/A N/A N/A N/A 9.8.1.2528 N/A N/A V2.6.11 N/A N/A Support X-Series
K-Frame v14.6.2 V4.2.2d01 K-Frame v14.6.1 N/A 6.3 8.5 Alpha 23513 MVS-8000G , XVS-7000

4

Installation and Configuration Considerations

Category Others

Table 1. Release Matrix Application Router Support Stratus Densité

Model

Version
via iControl Solo v7.4
6.9.0.0
Densité controller firmware v2.3.1, GPI-1501 firmware version (1.0.0)

Installation and Configuration

Considerations
· Ignite 11.8.2 requires Microsoft .NET 4.6.2 and Microsoft Visual C++ Redistributable for VS 2017.
· With 11.8.2, desktop experience must be enabled otherwise graphics might be compromised.
Hardware Installation
Only qualified Grass Valley Service Engineers are authorized to install the Ignite Live Production Control System. Contact your local Grass Valley representative, your Grass Valley Ignite Technical Service representative, or Grass Valley Support Center.
Software Installation
Only qualified Grass Valley Service Engineers are authorized to install Ignite Live Production Control System Release 11.8.2 software. Contact your local Grass Valley representative, your Grass Valley Ignite Technical Service representative, or Grass Valley Support Center. Installation has two parts:
· MOP server
· Ignite
New Installation
1 Run the IgniteMOPInstaller.msi for 11.7 on the MOP server. 2 Run the Ignite 11.8.2 Installer.exe on the Ignite workstation. 3 Select the feature set from installer options (Audio, Switcher Type, etc.) and finish the
installation.

5

IGNITE Release Notes
Upgrade Installation
MOP Server Upgrade
Caution It is imperative that you follow these instructions when UPGRADING to MOP Server 11.7 from a previous version.
+ + NNoottee This update requires more than just new software, but also has a database update component.
1 Stop all MOP services before the upgrade. 2 Manually uninstall MOP Server via Windows add/remove programs. 3 Run IgniteMOPInstaller.msi for 11.7 on the MOP server. 4 Launch the Ignite MOP Utility and select as below:
· Services > Start Services · Settings > Configure Database 5 Ensure that the Database Version is 6 or less.
+ + NNoottee In the following step, the application might freeze for a few seconds, this is normal.
6 Under Upgrade, click Upgrade Database. When done, the: · Messages window displays Upgrade complete · Database Version displays 7
Ignite Upgrade
+ + NNoottee If a customer is being upgraded, and is using different audio, or a different switcher (i.e. going from Klotz to Calrec, or Kayak to Kayenne), after restoring setups, you will need to restore some registry settings manually. Refer to http://grassvalleyautomation.com/wiki/index.php?title=Ignite_Restore for more information.
If a customer is upgrading from any version of Ignite prior to: · 5.2.0.0, you must run the AlloyConversionUtilities found in the Ignite installation folder
6

Installation and Configuration Software Installation
· 5.1.1, you must convert the customer's TME & Macro library with the IgniteTMEProcessor found in the Ignite installation folder
1 Backup the GrassValley folder and the TBMS registry. 2 Copy the Ignite_11.7_FullInstall folder to the C:\Software directory. 3 Run the Ignite 11.8.2 Installer.exe to uninstall the previous version and backup
configuration files. 4 Take note of the name of the folder created in the D:\IgniteBackups folder. 5 Run the Ignite 11.8.2 Installer.exe on the Ignite workstation. 6 Select feature set from installer options ( such as Audio, Switcher Type, etc.) and finish
the installation.
+ + NNoottee Timed Events setting is disabled by default. To enable Timed Events, check Timed Events check box when it displays on the Ignite installation wizard.
7

Configuration Notes

IGNITE Release Notes

CONFIGURATION NOTE 1
+ + NNoottee Always perform a backup of the entire TME library before running a conversion via IgniteTMEProcessor.
If a user is being upgraded and has any TMEs that addressed the ScriptViewer to append scripts and/or load CGs from the CG list, the TMEs must be converted. In most cases, this is just a single TME (LP.tmx, LS.tmx, or something similar) that is embedded but if the customer uses multiple versions of this file type, all must be converted. Conversion is done via the IgniteTMEProcessor.exe in the root Ignite folder.

CONFIGURATION NOTE 2
· If a user is being upgraded and is not using ScriptViewer, or for any reason would prefer to not see the Miniviewer in the Ignite GUI, this must be modified in the registry.
HKEY_LOCAL_MACHINE\SOFTWARE\TBMS\IPS\SCRIPTGUI\MINIVIEWMODE 0 = No Miniviewer 1 = Miniviewer

· If the user is not using ScriptViewer, it is recommended that the SV row in the timeline track be removed and replaced with another track (e.g. CG, Kayak, Camera).
· If the user is not using ScriptViewer, in order to fill the space vacated by the Miniviewer module, it is recommended that the CG List GUI be changed to Wide mode from the Display Settings tab of the CG List Settings dialog box.

CONFIGURATION NOTE 3

You must install the Automation Soft Panel (ASP) driver in Ignite before installing the ASP in Windows and Android devices.
1 To get the ASP device into the Devices list in Ignite, run and install the Automation Soft Panel driver (version 2.1.5).

8

Installation and Configuration Software Installation
+ + NNoottee There is only one installer for both Katalyst and ASP, as the ASP driver is the same with the Katalyst driver. 2 To install ASP in Windows devices, download the ASP installer for Windows and run it. 3 When prompted, enter the number of ASP instances that you want to run in your system. A maximum of 6 simultaneous instances is supported by the installer.
4 Click Finish to complete the installation. 5 Click Start | All Programs | Grass Valley | Automation Soft Panel to launch an
instance of the ASP.
6 To install ASP on an Android device, configure the device to allow the installation of third party software as follows: a Go to the device's Settings | Lock screen and security |Security b Enable the Unknown sources setting.
9

c Tap OK when the dialog appears as below:

IGNITE Release Notes

7 Download the Automation Soft Panel APK file to the Android device. 8 Open the file manager application of your choice and find the APK file.
9 Tap on it and then tap Install to commence the installation process. 10 Once installation is complete, the Automation Soft Panel will be accessible from the
Apps drawer.
+ + NNoottee Just like with a Katalyst panel, Ignite connects to ASP devices when they are enabled in the current mode.
CONFIGURATION NOTE 4
For the delay operation with GPI16, a toggle is enabled in the registry to allow users to choose between ignoring the delay or waiting for the delay to complete when a play command is hit while GPI16 is performing a delay.
1 Ensure you already upgraded your Ignite application. 2 Run this file at C:\Program Files\GrassValley\Ignite\RegisterModules.exe 3 Select "R" when prompted. 4 Navigate to C:\Program Files\GrassValley\Ignite\MiscApps 5 Select a file for the buffer command to be On or Off from the list below:
· GPI_16_BufferCommandsOff64.reg · GPI_16_BufferCommandsOn64.reg 6 Double-click to execute the .reg file. A prompt appears with this confirmation dialog: "Are you sure you want to continue?" 7 Click Yes.
10

Installation and Configuration Software Installation
+ + NNoottee If Buffer Commands Off is selected, Ignite will execute the play command immediately and ignore the delay. If Buffer Commands On is selected, Ignite will execute the play command after the delay is complete.
CONFIGURATION NOTE 5 Ignite users with the latest Chyron HyperX driver or existing users with previous versions of the software suite must perform the following configuration in the Ignite device manager:
1 Launch the Ignite application. 2 On the Event Timeline module, select Setup | Configuration and Device Setup. 3 Select Chyron in the Devices Configuration screen and click Edit. 4 Enter the properties of the Chyron CG device. The Root Folder value should be set to
CAMIO4 if you have the latest Chyron HyperX driver.
+ + NNoottee For users of CAMIO 3 or earlier, you can leave the Root Folder field blank by default or insert values depending on the version of Chyron software suite in use. Possible values for the root folder are CAMIO, CAMIO2, and CAMIO3. 5 Click OK.
11

CONFIGURATION NOTE 6

IGNITE Release Notes

The support for VizRT Concept is disabled by default.
To enable it, add ALTERNATIVE_CONCEPT parameter to the registry as shown below. Set it to 1 and then only start Ignite. This is applicable to every channel.

To insert the Concept into Ignite, do the following: 1 In the CG hotkeys window, enter the correct path for profile and showname: <Profile>/<ShowName> 2 Open the TME page, and select the preload icon as shown below:
3 Enter the concept name in the Function text box. 4 Code your TME icon as below:
12

Installation and Configuration Software Installation
a The first icon from left is to change the concept. b The middle icon is to load a CG. c The last icon is to play a CG. CONFIGURATION NOTE 7 To setup a CG production cue for VizRT, please do the following: 1 Go to C:\Program Files\GrassValley\Ignite\ and launch IQConfigurator.exe from the directory. 2 In the IQ Configurator, select Tools | Production Cue Auto - generation to open the Production Cue Auto Generation table. 3 Right-click on the table and select Add New CG Entry to launch the Setup a CG Production Cue window.
4 Select VizRT as the CG Device and configure the CG production cue for your operation.
13

CONFIGURATION NOTE 8

IGNITE Release Notes

The support of tri-monitor display for Ignite application is on 16:9 monitors by default. For customers with 4:3 monitors, screen setting values must be manually modified in the registry.
· For KONNECT screen, edit values as shown in the location below: HKEY_LOCAL_MACHINE\SOFTWARE\TBMS\IPS\Switcher

Switch to decimal base in the registry for easy reference.

· For Ignite middle screen, edit values as shown in the location below: HKEY_LOCAL_MACHINE\SOFTWARE\TBMS\IPS\STUDIOG2
CONFIGURATION NOTE 9 To use the Densité Frame with GPI-1501 card for Tally control, the following configuration must be done in the Ignite device manager:
14

Installation and Configuration Software Installation
1 Launch the Ignite application. 2 On the Event Timeline module, select Setup | Configuration and Device Setup. 3 Select Densité Frame as the Device Type and enter device properties as below:
4 Click OK. If needed, you can also connect to more than one Densité Frame in order to access additional GPI-1501 cards.
5 Click Exit. 6 Navigate to C:\Program Files\GrassValley\Ignite\misc\DeviceData 7 Open the TallyConfiguration.xml file from the location above and edit the
configuration with your text editor. 8 You can map up to 64 Tally outputs (GPOs) and 32 Tally inputs (GPIs) to Densité
Frame-Slot-Pin sets.
15

IGNITE Release Notes
+ + NNoottee If upgrading from Videoframe to Densité Frame, there is no need to rebuild the event library provided that Ignite GPI/O addresses are mapped to Densité locations.
CONFIGURATION NOTE 10 To include the SSL System T Audio mixer in your operation, the following configuration must be done in the Ignite device manager:
1 Launch the Ignite application. 2 On the Event Timeline module, select Setup | Configuration and Device Setup. 3 Select properties for the device as follows:
a Device Type: SSL Mixer b Model: System T 4 Enter other properties as shown below:
+ + NNoottee The IP Port automatically changes to reflect the default port for System T or C10HD as one model or the other is selected from the drop-down list. 5 Click OK.
16

Installation and Configuration Software Installation
CONFIGURATION NOTE 11 To include the Wheatstone Series 4 audio mixer in your operation, the following configuration must be done in the Ignite device manager:
1 Launch the Ignite application. 2 On the Event Timeline module, select Setup | Configuration and Device Setup. 3 Select properties of the device as follows:
a Device Type: Wheatstone b Wheatstone Mixer Model: Series 4 4 Enter other properties as shown below:
5 Click OK. CONFIGURATION NOTE 12 To include theK-Frame V-Series switcher in your operation, the following configuration must be done in the Ignite device manager:
1 Launch the Ignite application. 2 On the Event Timeline module, select Setup | Configuration and Device Setup. 3 Select Device Type: KFrame V Series.
17

4 Enter properties of the K-Frame V-Series switcher as below:

IGNITE Release Notes

5 Click OK.

18

Open Source Software Information Apache

Open Source Software Information
For instructions on how to obtain a copy of any source code being made publicly available by Grass Valley related to software used in this Grass Valley product you may send your request in writing to:
Grass Valley Open Source Software Management
3499 Douglas-B-Floreani, QC Canada
Or email your request to:
ossManagement@grassvalley.com

Apache

This document contains additional information regarding licenses, acknowledgments and required copyright notices for open source packages used in this Grass Valley product. The software components listed below are used by Grass Valley's products.
License Apache 2.0

Copyright Text This product includes software developed by The Apache Software Foundation (http://www.apache.org/).

The Windows Installer is built with the Nullsoft Scriptable Install Sysem (NSIS), which is open source software. The original software and related information is available at http://nsis.sourceforge.net.

Java compilation software for JSP pages is provided by Eclipse, which is open source software. The orginal software and related infomation is available at http://www.eclipse.org.
Microsoft Public License
License Microsoft Public License 1.0 (Ms-PL 1.0)

19

IGNITE Release Notes
Copyright Text Microsoft Public License (Ms-PL)
This license governs use of the accompanying software. If you use the software, you accept this license. If you do not accept the license, do not use the software. 1. Definitions The terms "reproduce,""reproduction,""derivative works," and "distribution" have the same meaning here as under U.S. copyright law. A "contribution" is the original software, or any additions or changes to the software. A "contributor" is any person that distributes its contribution under this license. "Licensed patents" are a contributor's patent claims that read directly on its contribution. 2. Grant of Rights (A) Copyright Grant- Subject to the terms of this license, including the license conditions and limitations in section 3, each contributor grants you a non-exclusive, worldwide, royalty-free copyright license to reproduce its contribution, prepare derivative works of its contribution, and distribute its contribution or any derivative works that you create. (B) Patent Grant- Subject to the terms of this license, including the license conditions and limitations in section 3, each contributor grants you a non-exclusive, worldwide, royaltyfree license under its licensed patents to make, have made, use, sell, offer for sale, import, and/or otherwise dispose of its contribution in the software or derivative works of the contribution in the software. 3. Conditions and Limitations (A) No Trademark License- This license does not grant you rights to use any contributors' name, logo, or trademarks. (B) If you bring a patent claim against any contributor over patents that you claim are infringed by the software, your patent license from such contributor to the software ends automatically. (C) If you distribute any portion of the software, you must retain all copyright, patent, trademark, and attribution notices that are present in the software. (D) If you distribute any portion of the software in source code form, you may do so only under this license by including a complete copy of this license with your distribution. If you distribute any portion of the software in compiled or object code form, you may only do so under a license that complies with this license. (E) The software is licensed "as-is." You bear the risk of using it. The contributors give no express warranties, guarantees or conditions. You may have additional consumer rights under your local laws which this license cannot change. To the extent permitted under your local laws, the contributors exclude the implied warranties of merchantability, fitness for a particular purpose and non-infringement.
20

Open Source Software Information MIT

MIT

License MIT License (MIT)

Copyright Text The MIT License (MIT)

Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:

The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.

Mozilla

THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
License Mozilla Public License 2.0 (MPL 2.0)

Copyright Text This Source Code Form is subject to the terms of the Mozilla Public License, v. 2.0. If a copy of the MPL was not distributed with this file, you can obtain one at http://mozilla.org/MPL/2.0/.
NSubstitute
License BSD License

21

IGNITE Release Notes Copyright Text Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
22

Open Source Software Information NSubstitute
23

@Contact Us

Grass Valley Technical Support
For technical assistance, contact our international support center, at 1-800-547-8949 (US and Canada) or +1 530 478 4148.
To obtain a local phone number for the support center nearest you, please consult the Contact Us section of Grass Valley's website (www.grassvalley.com).
An online form for e-mail contact is also available from the website.

Corporate Head Office

Grass Valley

3499 Douglas-B.-Floreani

St-Laurent, Quebec H4S 2C6

Canada

Telephone: +1 514 333 1772

Fax:

+1 514 333 9828

www.grassvalley.com

24



References

Adobe PDF Library 15.0