Rheem XP40T06PV36U0 020352625676 0020352625676 1000035141
® PERFORMANCE® ENERGY STAR® Power Vent gas water heaters offer up to 150 foot vent run Efficiency n .65 - .70 UEF n S ome models are ENERGY STAR® rated Performance n F HR: 66 - 86 gallons n R ecovery: Up to 42.4 GPH at a 90° F rise for 50 and 40-gallon models, depending on model Self-Diagnostic System n Electronic diagnostic gas control valve for improved monitoring and service Low Emissions n E co-friendly burner, low NOx design Features n U ses indoor air for combustion; blower exhausts the flue gases n S tandard 120 VAC electrical connection n N ew whisper quiet blower Maintenance Free Burner System n E xclusive air/fuel shut-off device n M aintenance free no filter to clean n D isables the heater in the presence of flammable vapor accumulation Flexible Venting Options n Long venting lengths up to 150 equivalent feet n P VC, ABS, or CPVC vent pipe options n Vertical or horizontal termination Longer Life n Patented anode rod design provides long-lasting tank protection Plus... n Temperature and pressure relief valve included n Low lead compliant n D urable Silicon Nitride Ignitor (HSI) n High Ambient Temperature Service Kit available for installations from 100-175° F. See chart on page 2 for more information n Standard replacement parts Warranty n 6-Year limited warranty for tank and parts, 1-year full in-home labor warranty* *See written warranty for complete details Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. PERFORMANCE Power Vent 40 and 50-Gallon Capacities Up to 42,000 BTU/h Combustion Shut-off System Flame Arrestor Plate Maintenance Free LEED Point = 1 See specifications chart on back. 09/21 FORM NO. THD-PGPV N Rev. 10 ® Power Vent Specifications Fuel Type Nominal Rated Description Gallon Gallon Capacity Capacity Model Number Gas Input in Thous. BTU/h Recovery in G.P.H. 90° F Rise First Hour Rating (Gallons) Natural Gas Tall 50 48 XG50T06PV42UO 42 42.4 78 Natural Gas Short 50 48 XG50S06PV36UO 36 36.4 78 Natural Gas Tall 40 38 XG40T06PV40UO 40 40.4 86 Natural Gas Short 40 39 XG40S06PV36UO 36 36.4 66 Liquid Propane Tall 50 48 XP50T06PV42UO 42 42.4 78 Liquid Propane Tall 40 38 XP40T06PV36UO 36 36.4 71 Liquid Propane Short 40 39 XP40S06PV32UO 32 32.4 66 Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. Ht. to Top of Assembly A Tank Height B Diam. C 65-1/2 58 21-3/4 58-1/4 51-1/4 23-3/4 66-1/4 59 19-3/4 58-1/4 51-1/4 21-3/4 65-1/2 58 21-3/4 66-1/4 59 19-3/4 58-1/4 51-1/4 21-3/4 Ht. to Gas Conn. D 14 14 14 14 14 14 14 Water Conn. Center E 8 8 8 8 8 8 8 Ht. to Side T&P Valve F 52-1/2 44 53-1/2 44-1/4 52-1/2 53-1/2 44-1/4 Water Conn. Size G 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Ship Weight (LBS) Uniform Energy Factor (UEF) 170 0.68 185 0.70 137 0.69 161 0.65 170 0.68 137 0.68 161 0.65 ENERGY STAR® compliant POWER VENT ASSEMBLY LEED Point = 1 Model G HOT Maximum and Minimum Vent Lengths for 2 - 3" Vents up to 2,000 Ft. (609 m) Above Sea Level WATER CONNECTION E Gas Heater input Vent System Diameter Min. Allowed Equivalent Vent Length Max Allowed Equivalent Vent Length Vent System Termination Btu/hr. Inches Feet Meters Feet Meters 42,000, 2 7 2.1 55 16.7 45° Elbow All Natural & Propane 40,000, 36,000, 32,000 3 7 2.1 150 45.7 45° Elbow C ANODE ROD G COLD WATER CONNECTION T&P FITTING 3/4" N.P.T. Maximum and Minimum Vent Lengths for 2 - 3" Vents AB F From 2,000 Ft. (609 m) through 7,800 Ft. (2,377 m) Above Sea Level 1/2" Model Gas Heater Input Vent System Diameter Min. Allowed Equivalent Vent Length Max Allowed Equivalent Vent Length Vent System Termination Btu/hr. Inches Feet Meters Feet Meters D 2 40 Gallon Natural 40,000 3 7 2.1 25 7.6 45° Elbow 7 2.1 150 45.7 45° Elbow 2 40 Gallon Propane 36,000 3 7 2.1 35 10.6 45° Elbow 7 2.1 150 45.7 45° Elbow 2 40 Gallon Natural & Propane 36,000, 32,000 3 50 Gallon Natural & Propane 42,000, 36,000, 32,000 2 3 7 2.1 40 12.2 45° Elbow For the 2" and 3" vent, one 90° elbow is 7 2.1 150 45.7 45° Elbow approximately equal to 5 feet of pipe. One 45° elbow is approximately equal to 7 2.1 35 10.6 45° Elbow 2.5 feet of pipe. 7 2.1 150 45.7 45° Elbow High Ambient Installations Part Temperature Rating Vent Length SP21171High Ambient Temperature Kit 100-175° F First 10 equivalent feet of vent pipe and/or fittings be of CPVC or ABS See Use and Care Manual for additional information and instructions. Venting Material Required CPVC (Schedule 40, ASTM F441) ABS (Schedule 40, ASTM D2661) Fitting Material Required CPVC (Schedule 40, ASTM F438) ABS (Schedule 40 DWV, ASTM D2661) In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating · 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 · www.rheem.com 09/21 FORM NO. THD-PGPV N Rev. 10Adobe PDF Library 15.0 Adobe InDesign 16.2 (Macintosh)