Performance 40 Gal. Tall 6 Year 36,000 BTU Liquid Propane Power Vent Tank Water Heater Specification

Rheem XP40T06PV36U0 020352625676 0020352625676 1000035141

PDF preview unavailable. Download the PDF instead.

234ecc20-0b6c-4814-a24d-c2c4b59bae25
®

PERFORMANCE® ENERGY STAR® Power Vent gas water heaters offer up to 150 foot vent run

Efficiency
n .65 - .70 UEF
n S ome models are ENERGY STAR® rated
Performance
n F HR: 66 - 86 gallons
n R ecovery: Up to 42.4 GPH at a 90° F rise for 50 and 40-gallon models, depending on model
Self-Diagnostic System
n Electronic diagnostic gas control valve for improved monitoring and service
Low Emissions
n E co-friendly burner, low NOx design
Features
n U ses indoor air for combustion; blower exhausts the flue gases
n S tandard 120 VAC electrical connection
n N ew whisper quiet blower
Maintenance Free Burner System
n E xclusive air/fuel shut-off device
n M aintenance free ­ no filter to clean
n D isables the heater in the presence of flammable vapor accumulation

Flexible Venting Options
n Long venting lengths up to 150 equivalent feet
n P VC, ABS, or CPVC vent pipe options
n Vertical or horizontal termination
Longer Life
n Patented anode rod design provides long-lasting tank protection
Plus...
n Temperature and pressure relief valve included
n Low lead compliant
n D urable Silicon Nitride Ignitor (HSI)
n High Ambient Temperature Service Kit available for installations from 100-175° F. See chart on page 2 for more information
n Standard replacement parts
Warranty
n 6-Year limited warranty for tank and parts, 1-year full in-home labor warranty*
*See written warranty for complete details
Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria.

PERFORMANCE Power Vent
40 and 50-Gallon Capacities Up to 42,000 BTU/h

Combustion Shut-off System

Flame Arrestor Plate

Maintenance Free

LEED Point = 1
See specifications chart on back.

09/21 FORM NO. THD-PGPV N Rev. 10

®
Power Vent Specifications

Fuel Type

Nominal Rated Description Gallon Gallon
Capacity Capacity

Model Number

Gas Input in Thous.
BTU/h

Recovery in G.P.H. 90° F Rise

First Hour Rating (Gallons)

Natural Gas

Tall

50

48

XG50T06PV42UO

42

42.4

78

Natural Gas

Short

50

48

XG50S06PV36UO

36

36.4

78

Natural Gas

Tall

40

38

XG40T06PV40UO

40

40.4

86

Natural Gas

Short

40

39

XG40S06PV36UO

36

36.4

66

Liquid Propane

Tall

50

48

XP50T06PV42UO

42

42.4

78

Liquid Propane

Tall

40

38

XP40T06PV36UO

36

36.4

71

Liquid Propane Short

40

39

XP40S06PV32UO

32

32.4

66

Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.

Ht. to Top of Assembly
A

Tank Height
B

Diam. C

65-1/2

58 21-3/4

58-1/4 51-1/4 23-3/4

66-1/4

59 19-3/4

58-1/4 51-1/4 21-3/4

65-1/2

58 21-3/4

66-1/4

59 19-3/4

58-1/4 51-1/4 21-3/4

Ht. to Gas Conn. D
14
14
14
14
14
14
14

Water Conn. Center
E
8
8
8
8
8
8
8

Ht. to Side T&P Valve
F
52-1/2 44
53-1/2 44-1/4 52-1/2 53-1/2 44-1/4

Water Conn. Size
G
3/4
3/4
3/4
3/4
3/4
3/4
3/4

Ship Weight (LBS)

Uniform Energy Factor (UEF)

170

0.68

185

0.70

137

0.69

161

0.65

170

0.68

137

0.68

161

0.65

ENERGY STAR® compliant

POWER VENT ASSEMBLY

LEED Point = 1
Model

G

HOT

Maximum and Minimum Vent Lengths for 2 - 3" Vents up to 2,000 Ft. (609 m) Above Sea Level

WATER CONNECTION
E

Gas

Heater input

Vent System Diameter

Min. Allowed Equivalent Vent Length

Max Allowed Equivalent Vent Length

Vent System Termination

Btu/hr.

Inches

Feet

Meters

Feet

Meters

42,000,

2

7

2.1

55

16.7

45° Elbow

All

Natural & Propane

40,000, 36,000,

32,000

3

7

2.1

150

45.7

45° Elbow

C

ANODE ROD
G
COLD WATER CONNECTION T&P FITTING 3/4" N.P.T.

Maximum and Minimum Vent Lengths for 2 - 3" Vents

AB

F

From 2,000 Ft. (609 m) through 7,800 Ft. (2,377 m) Above Sea Level

1/2"

Model

Gas

Heater Input

Vent System Diameter

Min. Allowed Equivalent Vent Length

Max Allowed Equivalent Vent Length

Vent System Termination

Btu/hr.

Inches

Feet

Meters

Feet

Meters

D

2

40 Gallon Natural

40,000

3

7

2.1

25

7.6

45° Elbow

7

2.1

150

45.7

45° Elbow

2

40 Gallon Propane

36,000

3

7

2.1

35

10.6

45° Elbow

7

2.1

150

45.7

45° Elbow

2

40 Gallon

Natural & Propane

36,000, 32,000

3

50 Gallon

Natural & Propane

42,000, 36,000, 32,000

2 3

7

2.1

40

12.2

45° Elbow

For the 2" and 3" vent, one 90° elbow is

7

2.1

150

45.7

45° Elbow approximately equal to 5 feet of pipe.

One 45° elbow is approximately equal to

7

2.1

35

10.6

45° Elbow 2.5 feet of pipe.

7

2.1

150

45.7

45° Elbow

High Ambient Installations

Part

Temperature Rating

Vent Length

SP21171High Ambient Temperature Kit

100-175° F

First 10 equivalent feet of vent pipe and/or fittings be of CPVC or ABS

See Use and Care Manual for additional information and instructions.

Venting Material Required
CPVC (Schedule 40, ASTM F441)
ABS (Schedule 40, ASTM D2661)

Fitting Material Required
CPVC (Schedule 40, ASTM F438)
ABS (Schedule 40 DWV, ASTM D2661)

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating · 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 · www.rheem.com
09/21 FORM NO. THD-PGPV N Rev. 10


Adobe PDF Library 15.0 Adobe InDesign 16.2 (Macintosh)