General
NOTIFIER's AMPS-24/E is an addressable power supply and battery charger with up to three 24 VDC outputs. It operates in either FlashScan® or CLIP (Classic Loop Interface Protocol) mode with the NFS-3030/NFS2-3030 Fire Alarm Control Panel (FACP). It can also be used as the primary power supply for the NCA-2 Network Control Annunciator.
Product Image Description
A photograph shows the NOTIFIER AMPS-24/E unit. It is a black, rectangular electronic device with various connectors, labels, and a prominent warning sticker indicating high voltage and caution. The unit is shown mounted within a metal enclosure, suggesting its integration into a larger system.
Features
- Addressable by NFS-3030/NFS2-3030 FACP.
- Selectable charging current charges 7 AH to 200 AH batteries.
- Isolated Signaling Line Circuit (SLC) interface.
- Trouble bus input for use with normally-open dry contacts or open-collector circuit.
- USB Type B connector for programming installation parameters.
- Brownout detection.
- Battery/battery charger supervision.
- Secondary Power Auxiliary Outputs: 24V @ 0.5A and 5V @ 0.15A.
- AC loss detection and AC loss delay reporting.
- Mounts in a CAB-4 Series enclosure, EQ Cabinet Series enclosure, BB-25, BB-100, or BB-200 Battery Backbox.
Specifications
Primary (AC) power: AMPS24: 110-120 VAC 50/60 Hz input, 5 A maximum; AMPS24E: 220-240 VAC 50/60 Hz input, 2.5 A maximum.
MAIN 24V Output: Filtered power-limited power. Refer to table for configuration/current information.
Charger Setting/ Battery Size | Main 24V (TB 1 on Main Control Unit) Max. Current | *Total AUX 24V (TB3 on Main Control Unit with TB2 on CPS-24) Max. Current |
---|---|---|
1A/7-26AH Batteries | 5A | 3A |
2A/12-60AH Batteries | 5A | 3A |
5A/55-200AH Configuration 1 | 5A | 0A |
5A/55-200AH Configuration 2 | 3A | 1A |
Disabled | 5A | 5A |
* Maximum current for all AUX 24 volt outputs. Note that TB2 on CPS-24 is limited to 0.5A.
AUX 24V: Provides filtered power-limited power for additional components. Refer to table above for configuration/current information.
Secondary power (battery) charging circuit: Current-limited, sealed lead-acid battery charger which will charge 7 to 200 AH batteries.
Selectable charging current: 1.0 A, 2.0 A or 5.0 A.
Secondary power auxiliary outputs.
Wire sizes: 10 AWG (5.26 mm²) to 22 AWG (0.326 mm²).
Battery fuse (F2): 15 A, fast-acting.
Shipping Weight: 4.25 lb
Agency Listings and Approvals
These listings and approvals apply to the AMPS-24/E power supply. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.
- UL: S635
- ULC: CS118
- City of Chicago
- City of Denver
- MEA: 345-02-E
- CSFM: 7165-0028:224
- FM: Approved
- FDNY: #6026
Product Line Information
AMPS-24: Addressable power supply/battery charger
AMPS-24E: Same as AMPS-24: 220-240VAC operation
Legal and Contact Information
FlashScan® is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.
This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. Visit www.notifier.com.
Document DN-6883:B, Revision Date: 10/15/09.
This product is made in the U.S.A.
Related Documents
![]() | NOTIFIER AMPS-24/E Intelligent Power Supply Manual This manual provides comprehensive guidance for the NOTIFIER AMPS-24/E Intelligent Power Supply and Battery Charger. It details installation, configuration, specifications, wiring, programming, and power supply calculations for fire alarm and life safety systems, ensuring compliance with standards like NFPA 72 and UL 864. |
![]() | Notifier NCD Network Control Display: Features and Specifications Explore the Notifier NCD Network Control Display, a next-generation annunciator for the NOTI FIRE NET network. Learn about its advanced features, hardware capabilities, and system integration for fire alarm control. |
![]() | NOTIFIER Device Compatibility Document: Fire Alarm System Component Specifications This document provides comprehensive compatibility specifications for NOTIFIER fire alarm system components, including control panels, notification appliances, and detectors from various manufacturers, essential for system design and installation. |
![]() | Notifier ACM-8R Relay Module: Technical Overview and Specifications Detailed overview of the Notifier ACM-8R Relay Module, a component for ACS class fire alarm control panels, including features, specifications, mounting, and agency approvals. |
![]() | Notifier NFS2-3030 Programming Manual Comprehensive programming manual for the NOTIFIER NFS2-3030 Fire Alarm Control Panel (FACP), detailing system configuration, device setup, and operational parameters for fire safety applications. |
![]() | NOTIFIER UDACT-2: Universal Digital Alarm Communicator/Transmitter Instruction Manual This manual provides comprehensive installation, programming, and operational guidance for the NOTIFIER UDACT-2 Universal Digital Alarm Communicator/Transmitter, a key component for fire alarm and emergency communication systems. |
![]() | Notifier NFS2-3030 Operations Manual: Fire Alarm Control Panel Guide Comprehensive operations manual for the Notifier NFS2-3030 Fire Alarm Control Panel (FACP). Learn about system features, installation precautions, operation, and troubleshooting. |
![]() | NOTIFIER NCD Network Control Display: Features, Specifications, and Applications Comprehensive data sheet for the NOTIFIER NCD Network Control Display, detailing its advanced features, hardware specifications, system integration with NOTIFIER INSPIRE and ONYX series fire alarm control panels, and agency approvals. |