ADVANCE SERIES SINGLE ZONE MINI SPLIT | J.A. Marino Automatic Heating Supply
Ductless HVAC Quick Reference Guide Plus Quick Reference Guide Single-Zone Systems Highwalls Built-in WiFi Adaptable with WiFi Adapter QAWF01A Max Operating Range 9/12TE1VHA: Cooling: 14~115°F (-10~46°C) Heating: -4~75°F (-20-24°C) 09/12TE2VHA, 09/12/18/24TE2HDA: Cooling: -4~115°F (-40~46°C) Heating: -4~75°F (-20-24°C) 18/24TE2VHA: Cooling: 0~115°F (-18~46°C) Heating: -4~75°F (-20-24°C) 24/30/36TE2HFA: Cooling: -40~115°F (-40~46°C) Heating: -4~75°F (-20-24°C) Cooling operating range varies by model. Cooling below 23°F (-5°C) requires wind baffle. 115V Low Ambient Cooling Size Indoor Model Outdoor Model AHRI# Max Heat @ 5oF SEER/ EER/ HSPF SEER2/EER2/ HSPF2 (IV) Line Set: Liquid Suction Min/ Max Min Max Line Fuse Circuit WiFi Length Size A Amp Standard Controller Optional Controller 9K AW09TE1VHA 1U09TE1VHA 10191421 6,900 16/11/9 17.5/10.5/9.5 1/4"- 3/8" 10'/66' 20 18 12K AW12TE1VHA 1U12TE1VHA 10191422 8,930 16/11/9 17/9.5/9 1/4"- 3/8" 10'/66' 20 18 AW09TE2VHA 1U09TE2VHA 206551253 6,000 18/11/10 -- 1/4"- 3/8" 10'/66' 15 12 9K AW09TC2HDA 1U09TE2HDA 210715479 7,000 18/11/10 19/11/9 1/4"- 3/8" 10'/66' 15 12 AW12TE2VHA 1U12TE2VHA 206551254 8,500 18/11/10 -- 1/4"- 3/8" 10'/66' 15 12 12K AW12TC2HDA 1U12TE2HDA 210715480 8,400 18/11/10 19/11/9.2 1/4"- 3/8" 10'/66' 15 12 AW18TE2VHA 1U18TE2VHA 10191423 13,600 18/10/10.5 -- 1/4"- 1/2" 10'/83' 20 17 18K AW18TC2HDA 1U18TE2HDA 209938278 13,000 19/11/10 19/11/9 1/4"- 1/2" 10'/83' 25 18 WJ01X24721* QACT17A** YR-E16B** YR-E17** (See note, below) AW24TE2VHA 1U24TE2VHA 10191424 16,400 18/10/10 -- 1/4"- 1/2" 10'/83' 25 19 24K AW24TC2HDA 1U24TE2HDA 209938279 16,700 19/9.5/10 19/9.5/9 1/4"- 1/2" 10'/83' 30 23 24K AW24TL2HFA 1U24TL2HFA 207769097 21,800 20/11/10 20/11/9.5 3/8"-5/8" 10'/165' 30 27 30K AW30TL2HFA 1U3036TL2HFA 207769098 21,800 18/9.5/9.5 18/9.5/9 3/8"-5/8" 10'/165' 30 27 36K AW36TL2HFA 1U3036TL2HFA 207769099 22,000 17.5/8/9.5 17.5/8/9 3/8"-5/8" 10'/165' 30 27 QACT17A WJ01X24721* YR-E16B YR-E17 NOTE: WK-B controller adapter not required for AW**TC2HDA models Plus Max Operating Range Cooling: 14~115°F (-10~46°C) Heating: -15~75°F (-26-24°C) Cooling below 23°F (-5°C) requires wind baffle. Size Indoor Model Outdoor Model AHRI# Max Heat @ 5oF SEER/EER/ HSPF SEER2/EER2/ HSPF2 (IV) Line Set: Liquid Suction Min/Max Max Min Line Fuse Circuit WiFi Length Size A Amp Standard Controller Optional Controller 9K AW09ES2VHB 1U09AP2VHA 202583709 10,000 23.5/14.5/10.5 23.5/14.5/9.3 1/4"- 3/8" 10'/50' 15 11 12K AW12ES2VHB 1U12AP2VHA 202583711 13,000 23/12.5/11 23/12.5/10.2 1/4"- 3/8" 10'/50' 15 11 15K AW15ES2VHB 1U15AP2VHA 202583712 16,000 21.5/12.5/10.5 21.5/12.5/9.6 1/4"- 1/2" 10'/83' 20 14 18K AW18ES2VHB 1U18AP2VHA 202583710 17,000 21/12.5/10.5 21/12.5/9.5 1/4"- 1/2" 10'/83' 20 14 QACT17A** WJ01X24721* YR-E16B** YR-E17** 24K AW24ES2VHB 1U24AP2VHA 202583713 20,000 20/12.5/10.5 20/12.5/9.5 1/4"- 1/2" 10'/83' 30 20 Max Operating Range Built-in WiFi 09/12/18EH2VHE: Cooling: 14~115°F (-10~46°C) Heating: -31~75°F (-35-24°C) 24/3036LP2HDA: Cooling: -4°F~115°F (-20~46°C) Heating: -15°F~75°F (-26~46°C) Cooling below 23°F (-5°C) requires wind baffle. Size Indoor Model Outdoor Model AHRI# Max Heat @ 5oF SEER/EER/ HSPF SEER2/ EER2/ HSPF2 (IV) Line Set: Liquid Suction Min/Max Line Length Max Fuse Size A Min Circuit Amp WiFi Standard Controller 9K AW09EH2VHD 1U09EH2VHE 206445819 12,000 30/16/15.2 30/16/14 1/4"- 1/2" 10'/50' 15 13 12K AW12EH2VHD 1U12EH2VHE 206389351 17,000 27/15/13 27/15/13 1/4"- 1/2" 10'/50' 20 14 18K AW18EH2VHD 1U18EH2VHE 206445820 20,000 23/13/12 23/13/11 1/4"- 1/2" 10'/83' 30 20 24K AW24TL2HFA 1U24LP2HDA 211744601 22,000 -- 21/11/10 3/8" - 5/8" 10'/165' 25 21 WJ26X27153* 30K AW30TL2HFA 1U3036LP2HDA 211744604 25,800 -- 19/8.8/9 3/8" - 3/4" 10'/165' 30 26 36K AW36TL2HFA 1U3036LP2HDA 211744606 26,200 -- 18/8.2/9 3/8" - 3/4" 10'/165' 30 26 Optional Controller QACT17A YR-E16B YR-E17 Pro Operating Range Cooling: 0~115°F (-18~46°C) Heating: -4~75°F (-20-24°C) Cooling below 23°F (-5°C) requires wind baffle. Size Indoor Model Outdoor Model AHRI# Max Heat @ 5oF 24K AW24LP2VHA 1U24LP2VHA 10221212 20,030 36K AW36LP2VHA 1U36LP2VHA 10225937 28,880 SEER/EER/ HSPF 17/10/10 17/8.6/10 Line Set: Liquid Suction Min/Max Line Length 3/8"- 5/8" 10'/165' 3/8"- 5/8" 10'/165' Max Fuse Size A 25 30 Min Circuit WiFi Amp Standard Controller Optional Controller 21 QACT17A** WJ01X24721* YR-E16B** 26 YR-E17** *Remote controller is shipped with indoor unit. **Requires WK-B adapter. Built-in WiFi Adaptable with WiFi Adapter QAWF01A Ducted Size Indoor Model 9K USYM09UCDSA 12K USYM12UCDSA 18K USYM18UCDSA 24K USYM24UCDDA 30K USYM30UCDDA 36K USYM36UCDDA 42K USYM42UCDDA 48K USYM48UCDDA Consoles Max Operating Range 09/12/18EH2VHE: Cooling: 14~115°F (-10~46°C) Heating: -31~75°F (-35-24°C) 24/3036/4248LP2HDA: Cooling: -4°F~115°F (-20~46°C) Heating: -15°F~75°F (-26~4°C) Cooling operating range varies by model. Cooling below 23°F (-5°C) requires wind baffle.. Outdoor Model 1U09EH2VHE 1U12EH2VHE 1U18EH2VHE 1U24LP2HDA 1U3036LP2HDA 1U3036LP2HDA 1U4248LP2HDA 1U4248LP2HDA AHRI# Heat SEER/EER/ SEER2/EER2/ @ 5oF HSPF HSPF2 (IV) Line Set: Liquid Suction Min/ Max Min Max Line Fuse Circuit WiFi Length Size A Amp Standard Controller Optional Controller 206608650 10,000 21/12.5/11 -- 1/4"- 3/8" 10'/50' 15 13 206389354 12,000 20/12.5/10.5 -- 1/4"- 3/8" 10'/50' 20 14 206608651 19,000 19/11.5/10 -- 1/4"- 1/2" 10'/83' 30 20 211727008 20,000 -- 16.5/9.5/8.1 3/8" - 5/8" 10'/165' 25 21 211727009 23,800 -- 15.2/9/9 3/8" - 3/4"* 10'/165' 30 26 211727010 25,600 -- 15/8/9 3/8" - 3/4"* 10'/165' 30 26 211729105 36,800 -- 15.2/7.8/8.7 3/8" - 3/4"* 10'/230' 40 35 Wired controller must be purchased separately QACT17A YR-E16B YR-E17 211729106 35,600 -- 15.2/7.3/8.8 3/8" - 3/4"* 10'/230' 40 35 * Standard lineset size is 3/4", a 3/4" to 5/8" adapter will be shipped with outdoor unit for matching the indoor lineset size. Recommended to use adapter on the indoor side. Max Operating Range Cooling: 14~115°F (-10~46°C) Heating: -31~75°F (-35-24°C) Cooling below 23°F (-5°C) requires wind baffle. Size Indoor Model Outdoor Model AHRI# Max Heat @ 5oF SEER/EER/ HSPF SEER2/EER2/ HSPF2 (IV) Line Set: Liquid Suction Min/ Max Min Max Line Fuse Circuit WiFi Length Size A Amp Standard Controller 9K USYF09UCDWA 1U09EH2VHE 206608652 9,000 20/11/10 20/11/8.7 1/4"- 3/8" 10'/50' 15 13 12K USYF12UCDWA 1U12EH2VHE 206389355 10,000 20/12.5/10 20/12.5/9.5 1/4"- 3/8" 10'/50' 20 14 WJ01X24721* 18K USYF18UCDWA 1U18EH2VHE 206608653 15,000 18/10/9 17.5/10/8.5 1/4"- 1/2" 10'/83' 30 20 Compact Cassettes Optional Controller QACT17A YR-E16B YR-E17 Max Operating Range Cooling: 14~115°F (-10~46°C) Heating: -31~75°F (-35-24°C) Cooling below 23°F (-5°C) requires wind baffle. Size Indoor Model Outdoor Model AHRI# Max Heat @ 5oF SEER/EER/ SEER2/EER2/ HSPF HSPF2 (IV) Line Set: Liquid Suction Min/ Max Min Max Line Fuse Circuit WiFi Length Size A Amp Standard Controller Optional Controller 9K AB09SC2VHA 1U09EH2VHE 206445025 9,000 20/10.5/9 20/10.5/7.9 1/4"- 3/8" 10'/50' 15 13 NA QACT17A 12K AB12SC2VHA 1U12EH2VHE 206389356 11,000 20/12.5/10 20/12.5/9 1/4"- 3/8" 10'/50' 20 14 NA WJ01X24721* YR-E16B 18K AB18SC2VHA 1U18EH2VHE 206445026 17,000 16/10.5/9 15.8/10.5/8.1 1/4"- 1/2" 10'/83' 30 20 NA YR-E17 Large Cassettes Size Indoor Model 24K USYL24UCDDA 30K USYL30UCDDA 36K USYL36UCDDA 42K USYL42UCDDA 48K USYL48UCDDA Outdoor Model 1U24LP2HDA 1U3036LP2HDA 1U3036LP2HDA 1U4248LP2HDA 1U4248LP2HDA Max Operating Range Cooling: -4°F~115°F (-20~46°C) Heating: -15°F~75°F (-26~4°C) Cooling below 23°F (-5°C) requires wind baffle. AHRI# Max Heat SEER2/EER2/ Line Set: Liq- Min/Max @ 5oF HSPF2 (IV) uid Suction Line Length 211744600 211744602 211744604 211744605 211744607 19,000 26,800 26,600 32,800 33,000 19/11/8.6 18/10.6/9.2 18/9.5/9 18/8.7/8.5 17/8/8.5 3/8" - 5/8" 3/8" - 3/4" 3/8" - 3/4" 3/8" - 3/4" 3/8" - 3/4" 10'/165' 10'/165' 10'/165' 10'/230' 10'/230' Max Fuse Size A 25 30 30 40 40 Min Circuit WiFi Amp 21 26 26 35 35 Standard Controller WJ01X24721* Optional Controller QACT17A YR-E16B YR-E17 Pro Max Operating Range Cooling: 0~115°F (-18~46°C) Heating: -4~75°F (-20-24°C) Cooling below 23°F (-5°C) requires wind baffle. Size Indoor Model Outdoor Model AHRI# Max Heat @ 5oF SEER/EER/ HSPF Line Set: Liquid Suction Min/ Max Line Length Max Fuse Size A Min Circuit WiFi Amp Standard Controller Optional Controller Cassette 3' x 3' 24K AL24LP2VHA 1U24LP2VHA 36K AL36LP2VHA 1U36LP2VHA 48K AL48LP2VHA 1U48LP2VHA 10225933 16,520 17/11.5/10 3/8"- 5/8" 10'/165' 25 21 10225936 21,050 17/10/10.3 3/8"- 5/8" 10'/165' 30 26 10225938 32,380 17/10.5/10.5 3/8"- 5/8" 10'/230' 40 35 PB-950KB grille required for Cassette. Condensate pump included. NA QACT17A NA YR-HBS01* YR-E16B NA YR-E17 High Static Ducted 36K AM36LP2VHA 1U36LP2VHA 10225935 23,140 17/10/10.5 3/8"- 5/8" 10'/165' 30 48K AM48LP2VHA 1U48LP2VHA 10225939 31,200 16.9/10/10 3/8"- 5/8" 10'/230' 40 26 35 NA NA YR-E17* QACT17A YR-E16B Use 1/2 x 3/8 suction line adapter shipped with outdoor unit *Remote controller is shipped with indoor unit. **Requires WK-B adapter. Quick Reference Guide Multi-Zone Systems Multi-Zone Outdoor Units Max Operating Range Cooling: 14~115°F (-10~46°C) Heating: -15~75°F (-26-24°C) Cooling below 23°F (-5°C) requires wind baffle. Size Outdoor Model Max Line All Comb. Max Heat @ 5oF (Non Ducted) SEER/EER/ HSPF Non Ducted SEER/EER/ HSPF Ducted SEER2/EER2/ SEER2/EER2/ AHRI# HSPF 2 (IV) HSPF 2 (IV) Non Ducted Ducted Non Ducted Ducted Max Min Fuse Circuit Size A Amp 20K 2U20EH2HDA 165' 20,988 18/12/10.2 16/11/10 18/12/10.2 16/11/9.8 210082195 210151026 25 20 24K 3U24EH2HDA 197' 23,471 19.5/12/10.5 16.8/11/10 19.5/12/10.2 16.8/11/9.5 210082198 210082199 30 23 36K 4U36EH2HDA 230 30,623 18.5/9.3/11 15.2/8.8/9.5 19/9.3/9.4 15.7/8.8/8.7 210082201 210151027 40 33 Max Operating Range Cooling: 14~115°F (-10~46°C) Heating: -4~75°F (-20-24°C) Cooling below 23°F (-5°C) requires wind baffle. Size Outdoor Model Max Line All Comb. Max Heat @ 5oF (Non Ducted) SEER/EER/ HSPF Non Ducted SEER/EER/ SEER2/EER2/ SEER2/EER2/ AHRI# HSPF Ducted HSPF 2 (IV) HSPF 2 (IV) Non Ducted Ducted Non Ducted Ducted Max Min Fuse Circuit Size A Amp 18K 2U18MS2HDA 98' 13,700 20/12.5/ 11 18.0/11.5/9.4 21/12.7/10 18/11.2/8.5 207698996 207722661 30 19 24K 3U24MS2HDA 197' 13,900 21/12.5/10.5 16.0/11.0/9 22/12.8/10 16/11/9 207698998 207722662 30 22 36K 4U36MS2HDA 230' 22,000 18/9/ 10.5 15.6/8.8/9.3 19/9/9.4 16/8.8/8.4 207802647 207802648 30 26 42K 5U42MS2HDA 262' 26,176 16/7.8/10 14.2/7.2/10 18/7.8/8.8 14.8/7.2/8.8 210404027 210404028 40 33 Multi-Zone Indoor Units Built-in WiFi Adaptable with WiFi Adapter QAWF01A Wall Mount Size Indoor Model Line Set: Liquid Suction WiFi Standard Controller Optional Controllers 7K AW07TC2HDA 1/4"- 3/8" 9K AW09TC2HDA 12K AW12TC2HDA 18K AW18TC2HDA 1/4"- 3/8" 1/4"- 3/8" 1/4"- 1/2" WJ01X24721* QACT17A YR-E16B YR-E17 24K AW24TC2HDA 1/4"- 1/2" Cassette 2' x 2' Size Indoor Model Line Set: Liquid Suction WiFi Standard Controller Optional Controllers 9K AB09SC2VHA 12K AB12SC2VHA 18K AB18SC2VHA 1/4"- 3/8" 1/4"- 3/8" 1/4"- 1/2" NA QACT17A NA WJ01X24721 YR-E16B NA YR-E17 PB-700KB grille required (Must order separate). Condensate pump included. Cassette 3' x 3' Size Indoor Model Line Set: Liquid Suction WiFi Standard Controller Optional Controller QACT17A 24K AL24LP2VHA 3/8"- 5/8" NA WJ01X24721* YR-E16B YR-E17 PB-950KB grille required (Must order separate). Condensate pump included. *Remote controller is shipped with indoor unit. **Requires WK-B adapter. Console Size Indoor Model Line Set: Liquid Suction WiFi 9K USYF09UCDWA 1/4"- 3/8" 12K USYF12UCDWA 1/4"- 3/8" 18K USYF18UCDWA 1/4"- 1/2" Standard Controller WJ01X24721 Optional Controllers QACT17A YR-E16B YR-E17 Mid-Static Duct Size Indoor Model Line Set: Liquid Suction WiFi 9K USYM09UCDSA 1/4"- 3/8" 12K USYM12UCDSA 1/4"- 3/8" 18K USYM18UCDSA 1/4"- 1/2" 24K USYM24UCDSA 3/8"- 5/8" Standard Controller Wired controller must be purchased separately Optional Controller QACT17A YR-E16B YR-E17 Slim Duct Size Indoor Model Line Set: Liquid Suction WiFi 7K AD07SL2VHB 1/4"- 3/8" NA 9K AD09SL2VHB 1/4"- 3/8" NA 12K AD12SL2VHB 1/4"- 3/8" NA 18K AD18SL2VHB 1/4"- 1/2" NA Standard Controller YR-E17 Optional Controller QACT17A YR-E16B High Static Duct Size Indoor Model Line Set: Liquid Suction WiFi Standard Controller 24K AM24LP2VHA 3/8"- 5/8" NA YR-E17 Optional Controller QACT17A YR-E16B Multi-Zone Matching Charts 2U20EH2HDA 2U18MS2HDA · No adapters required/shipped with 2U Models Combinations Port B Port A Two Zone Port Size: Port Size: 1/4" x 3/8" 1/4" x 3/8" 7 7 9 7 9 9 12 7 12 9 12 12 3U24EH2HDA (Ships with adapter E) 3U24MS2HDA (Ships with adapter D) · No adapters required for Ports B, A Two Zone Three Zone Combinations Port C Port B Port Size: MS: 1/4" x 3/8" EH: 1/4" x 1/2" 7 9 9 12 12 12 18 18 18 7 9 9 12 9 12 12 12 18 12 Required Adapter MS EH - E - E - E - E - E - E D - D - D - - E - E - E - E - E - E - E - E D - - E Port Size: 1/4" x 3/8" 7 7 9 7 9 12 7 9 12 7 7 9 7 9 9 9 12 7 12 Port A Port Size: 1/4" x 3/8" 7 7 7 7 9 7 9 7 7 9 Adapters A 1/4" to 3/8" (Liquid line for ports C & D) B 3/8" to 5/8" (Vapor line for port C) C 1/2" to 5/8" (Vapor line for port D) D 3/8" to 1/2" (Vapor line for port C) E 1/2" to 3/8" (Vapor line for port C or D) GEA Part # WJ01X23925 WJ01X23924 WJ01X23932 WJ01X26853 WJ01X26854 4U36EH2HDA (Ships with adapter A, C, D, and E) 4U36MS2HDA (Ships with adapter D and E) · No adapters required for Ports B, A Combinations Port D Port C Port B Port A Two Zone Three Zone Four Zone Port Size: 1/4" x 1/2" 18 18 24 24 24 18 18 24 9 12 12 12 18 12 18 18 12 18 24 24 24 18 24 24 24 18 7 9 9 12 9 12 9 12 12 12 18 12 18 12 12 18 18 24 12 24 12 18 Required Adapter* A, C A, C A, C A, C E E E E E E A, C A, C A, C A, C A, C A, C E E E E E E E E E E E E E A, C E A, C E - Port Size: 1/4" x 3/8" 9 12 7 9 12 18 24 24 9 9 9 12 7 12 9 9 12 12 7 9 9 12 12 12 12 18 7 7 9 7 9 9 9 9 12 9 7 12 9 12 12 9 12 7 12 9 12 12 Required Adapter* D A, B D A, B D D - Port Size: 1/4" x 3/8" 9 7 9 7 7 9 7 9 12 7 7 9 7 9 12 7 9 12 7 7 7 7 9 7 9 9 7 9 7 9 7 9 12 9 7 7 12 7 12 9 Port Size: 1/4" x 3/8" 7 7 7 7 7 7 9 7 7 9 7 7 7 9 7 7 7 7 9 7 12 9 * All 18K models require 1/4" liquid and 1/2" vapor linesets. 24K Model adapters vary. See color code: Applies to the following models with 3/8" and 5/8" port: AW24LP2VHA, USYM24UCDSA, USYL24UCDSA, AL24LP2VHA Applies to the following model with 1/4" and 1/2" port: AW24TC2HDA Quick Reference Guide Multi-Zone Systems Multi-Zone Matching Charts 5U42MS2HDA (Ships with two (2) adapter E) · No adapters required for Ports B, A Two Zone Three Zone Combinations Port E Port D Port C Port B Port A Port Size: Required Port Size: Required Port Size: Required Port Size: Port Size: 1/4" x 1/2" Adapter* 1/4" x 1/2" Adapter* 1/4" x 3/8" Adapter* 1/4" x 3/8" 1/4" x 3/8" 24K A, C - - - 7K - - - 18K - - - 9K - - - 24K A, C - - - 9K - - - 18K - - - 12K - - - 24K A, C - - - 12K - - - 18K - 18K - - - - - 24K A, C - 18K - - - - - 24K A, C - 24K A, C - - - - - 18K - - - 7K - 7K - 24K A, C - - - 7K - 7K - 12K E - - 9K - 7K - 18K - - - 9K - 7K - 24K A, C - - - 9K - 7K - 12K E - - 12K - 7K - 18K - - - 12K - 7K - 24K A, C - - - 12K - 7K - 18K - 18K - 7K - - - 24K A, C - 18K - 7K - - - 9K E - - 9K - 9K - 12K E - - 9K - 9K - 18K - - - 9K - 9K - 24K A, C - - - 9K - 9K - 12K E - - 12K - 9K - 18K - - - 12K - 9K - 24K A, C - - - 12K - 9K - 18K - 18K - 9K - - - 24K A, C - 18K - 9K - - - 12K E 12K E 12K - - - 18K - 12K E 12K - - - 24K A, C - 12K E 12K - - - 18K - 18K - 12K - - - 24K A, C - 18K - 12K - - - 18K - 18K - 18K D - - 7K E - - 7K - 7K 7K 9K E - - 7K - 7K 7K 12K E - - 7K - 7K 7K 18K - - - 7K - 7K 7K 24K A, C - - - 7K - 7K 7K 9K E - - 9K - 7K 7K 12K E - - 9K - 7K 7K 18K - - - 9K - 7K 7K 24K A, C - - - 9K - 7K 7K 12K E - - 12K - 7K 7K 18K - - - 12K - 7K 7K 24K A, C - - - 12K - 7K 7K 18K - 18K - 7K - 7K - 24K A, C - 18K - 7K - 7K - 9K E - - 9K - 9K 7K 12K E - - 9K - 9K 7K 18K - - - 9K - 9K 7K 24K A, C - - - 9K - 9K 7K 12K - - - 12K - 9K 7K 18K - - - 12K - 9K 7K 24K A, C - - - 12K - 9K 7K 18K - 18K - 9K - 7K - 12K E - - 12K - 12K 7K 18K - - - 12K - 12K 7K 24K A, C - - - 12K - 12K 7K 18K - 18K - 12K - 7K - 9K E - - 9K - 9K 9K Four Zone Four Zone (cont'd) Combinations Port E Port D Port C Port B Port A Port Size: Required Port Size: Required Port Size: Required Port Size: Port Size: 1/4" x 1/2" Adapter* 1/4" x 1/2" Adapter* 1/4" x 3/8" Adapter* 1/4" x 3/8" 1/4" x 3/8" 12K E - - 9K - 9K 9K 18K - - - 9K - 9K 9K 24K A, C - - - 9K - 9K 9K 12K E - - 12K - 9K 9K 18K - - - 12K - 9K 9K 24K A, C - - - 12K - 9K 9K 18K - 18K - 9K - 9K -- 12K E - - 12K - 12K 9K 18K - - - 12K - 12K 9K 12K E - - 12K - 12K 12K 18K - - - 12K - 12K 12K 18K - 18K - 12K - 9K - 7K E 7K E 7K - 7K 7K 9K E 7K E 7K - 7K 7K 12K E 7K E 7K - 7K 7K 18K - 7K E 7K - 7K 7K 9K E 9K E 7K - 7K 7K 12K E 9K E 7K - 7K 7K 18K - 9K E 7K - 7K 7K 24K A, C - 7K E 7K - 7K 7K 24K A, C - 9K E 7K - 7K 7K 24K A, C - 9K E 9K - 7K 7K 24K A, C - 9K E 9K - 9K 7K 24K A, C - 9K E 9K - 9K 9K 24K A, C - 12K E 7K - 7K 7K 24K A, C - 12K E 9K - 7K 7K 12K E 12K E 7K - 7K 7K 18K - 12K E 7K - 7K 7K 9K E 9K E 9K - 7K 7K 12K E 9K E 9K - 7K 7K 18K - 9K E 9K - 7K 7K 12K E 12K E 9K - 7K 7K 18K - 12K E 9K - 7K 7K 12K E 12K E 12K - 7K 7K 18K - 12K E 12K - 7K 7K 9K E 9K E 9K - 9K 7K 12K E 9K E 9K - 9K 7K 18K - 9K E 9K - 9K 7K 12K E 12K E 9K - 9K 7K 18K - 12K E 9K - 9K 7K 12K E 12K E 12K - 9K 7K 18K - 12K E 12K - 9K 7K 12K E 12K E 12K - 12K 7K 9K E 9K E 9K - 9K 9K 12K E 9K E 9K - 9K 9K 18K - 9K E 9K - 9K 9K 12K E 12K E 9K - 9K 9K 18K - 12K E 9K - 9K 9K 12K E 12K E 12K - 9K 9K 18K - 12K E 12K - 9K 9K 12K E 12K E 12K - 12K 9K 12K E 12K E 12K - 12K 12K Five Zone * All 18K models require 1/4" liquid and 1/2" vapor linesets. 24K Model adapters vary. See color code: Required for the following models with 3/8" and 5/8" port: AW24LP2VHA, USYM24UCDSA, USYL24UCDSA, AL24LP2VHA Required for the following model with 1/4" and 1/2" port: AW24TC2HDA Quick Reference Guide Accessories Cassette Panels Supply Plenums PB-700KB Panel for 2'x2' Cassette (Includes WJ01X24721 controller) Must order PB-700KB separately with the purchase of compact cassette models: AB09SC2VHA | AB12SC2VHA AB18SC2VHA UAPT0912A Supply Plenum for Ducted Indoor 09K, 12K Fits on the following Models: USYM09UCDSA | USYM12UCDSA PB-950KB Panel for 3'x3' Cassette Must order PB-950KB separately with the purchase of large cassette models: AL24LP2VHA | AL36LP2VHA AL48LP2VHA | USYL24UCDDA USYL30UCDDA| USYL36UCDDA USYL42UCDDA | USYL48UCDDA PB-950KD Panel for 3'x3' Cassette (Includes WJ01X24721 controller) Must order PB-950KD separately with the purchase of large cassette models: AL24LP2VHA | AL36LP2VHA AL48LP2VHA | USYL24UCDDA USYL30UCDDA| USYL36UCDDA USYL42UCDDA | USYL48UCDDA UAPT1824A Supply Plenum for Ducted Indoor 18K and 24K Fits on the following Models: USYM18UCDSA | USYM24UCDSA UAPT3048A Supply Plenum for Ducted Indoor 24K through 48K Fits on the following Models: USYM24UCDDA | USYM30UCDDA USYM36UCDDA | USYM42UCDDA USYM48UCDDA MERV Return Air Filter Boxes Return & Supply Air Grilles PAD0890RA Optional return air grille for Slim Duct models: AD07SL2VHB | AD09SL2VHB | AD12SL2VHB PAD1210RA Optional return air grille for Slim Duct model: AD18SL2VHB PAD0890SA Optional supply air grille for Slim Duct models: AD07SL2VHB | AD09SL2VHB | AD12SL2VHB PAD1210SA Optional supply grille for Slim Duct model: AD18SL2VHB UAMFB0912A Merv Return Air Filter Box for Ducted Indoor 09K and 12K Fits on the following Models: USYM09UCDSA | USYM12UCDSA UAMFB1824A Merv Return Air Filter Box for Ducted Indoor 18K and 24K Fits on the following Models: USYM18UCDSA | USYM24UCDSA USYM24UCDDA UAMFB3048A Merv Return Air Filter Box for Ducted Indoor 30K through 48K Fits on the following Models: USYM30UCDDA USYM36UCDDA USYM42UCDDA | USYM48UCDDA Quick Reference Guide Accessories Front Wind Baffles Required for low ambient cooling performance for mechanical or server room applications, and recommended when unit is installed facing prevailing winds. Features and Benefits · Increases unit reliability and performance in extremely cold temperatures. · Prevents outdoor fan counter-rotation. · Helps keep snow and ice from clogging the outdoor coil. · Protects the outdoor coil from high winds. · Easy installation. · Reduce indoor temperature fluctuation. Side and Back Wind Baffles (Snow Hood) Strongly recommended for cold climate heating and cooling applications. Features and Benefits · Reduces defrost cycles. · Helps maintain a comfortable indoor temperature. · Easy installation. · Helps keep snow and ice from clogging the outdoor coil. Mounts to front of unit Mounts to side of unit Mounts to rear of unit The wind baffles are fabricated from durable 20 gauge G90 galvanized steel. Both accessories are engineered to provide optimal performance when operating the outdoor unit in cold, harsh climates. TEMPO Outdoor Units ADVANCED PLUS ARCTIC FLEXFIT PRO ARCTIC MULTI FLEXFIT MULTI 1U09TE1VHA 1U12TE1VHA 1U09TE2VHA 1U09TE2HDA 1U12TE2VHA 1U12TE2HDA 1U18TE2VHA 1U18TE2HDA 1U24TE2VHA 1U24TE2HDA 1U24TL2HFA 1U3036TL2HFA 1U09AP2VHA 1U12AP2VHA 1U15AP2VHA 1U18AP2VHA 1U24AP2VHA 1U09EH2VHE 1U12EH2VHE 1U18EH2VHE 1U24LP2HDA 1U3036LP2HDA 1U4248LP2HDA 1U24LP2VHA 1U36LP2VHA 1U48LP2VHA 2U20EH2HDA 3U24EH2HDA 4U36EH2HDA 2U18MS2HDA 3U24MS2HDA 4U36MS2HDA 5U42MS2HDA Front Wind Baffle QAWB37A · ·· ·· QAWB38A · · ·* · · ·* QAWB40A QAWB41A · · · · · · QAWB42A ·· QAWB43A QAWB44A QAWB45A · · · UAWB46A · ··· ··· ·· UAWB47A ·· Side And Back Wind Baffle (Snow Hood) UAWB80A UAWB81A UAWB82A UAWB83A UAWB84A UAWB85A UAWB86A ·· ·· · ··· · · ·· ·· · ··· · ·· *Requires 2 wind baffles Quick Reference Guide Controllers Haier controls allow you to take command of your environment. With convenient user-friendly button layouts and clear graphic displays, the system can be easily set to meet and maintain all comfort needs. Wall Mounted Wired Remote Controllers Wireless Hand-Held Remote Controllers Color screen wired controller optional for Arctic, Advanced Plus, FlexFit Wall mount/ cassette/ slim duct Wired controller is shipped with Slim Duct and High Static Duct. Optional for Arctic, Advanced Plus, and FlexFit Wall Mount or Cassettes. YR-E16B QACT17A Power Supply Controllable Indoor Groups On/Off Modes Precise Temperature Control +/- 1F (+/- 0.5C) Fan Speed Adjustment Turbo Quiet Airflow Direction - Up Down Airflow Direction - Left Right Four-Way Cassette Blade Control Indoor Temperature Display Filter Change Reminder Clock Error Code Reporting/Recording Control Lock Daily Program Weekly Program Sleep Backlight Fahrenheit/Celsius Display Temperature Range Limit Temperature Compensation Static Pressure Setting Groups Setting Password 12V AC Up to 16 · Auto-Cool-Dry-Heat-Fan-Auto · · · · · · · · 500 hr · · · · · · · · · · · · · 12V AC Up to 16 · Auto-Cool-Dry-Heat-Fan-Auto · · · · · · · 500 hr · · · · · · · · Ships with Highwall equipped with motion sensor Ships with large Cassette Ships with Highwall and compact Cassette Cool only remote (optional for purchase separately) WJ26X27153 YR-HBS01 WJ01X24721 UCT30RWA 24-Hour Time · Individual Control · · · · Backlight · · · · Up & Down Louver Oscillating Control · · · · Left & Right Louver Oscillating Control · · · · Four-Way Cassette Air Supply Control · Child Lock · · · · Indoor LED Display On/Off · · · · Fahrenheit/Celsius Display · · · · Precise Temperature Control +/- 1F (+/- 0.5C) · · · · Motion Sensor · *Remote controller WJ01X24721 and WJ26X27153 are shipped with indoor unit. WK-B Wired controller interface kit, required when installing wired controllers YR-E17, YR-E16B or QACT17A on some highwall models (see compatibility charts for required applications). Quick Reference Guide Model Nomenclature Ductless Product Nomenclature 1U Product Category 18 Nominal Cooling Capacity TE Product Family 2 Voltage HD Major Marketing Revision A Minor Marketing Revision 1 Engineer Digit Product Category 1U: Single Zone Outdoor Product Family HD MS: FlexFit Multi VH 2U, 3U, 4U, 5U: Multi Zone Outdoor TE, TC: Tempo AW: Ductless Wall Mount Indoor EH: Arctic AB: Ductless Cassette Indoor AP, ES: Advanced (Plus) USYM: Ductless Mid-Static Indoor LC, TC, SL, SC, UC: FlexFit USYF: Ductless Console Indoor USYL: Large Cassette Indoor Nominal Cooling Capacity 07: 7K BTU 20: 20K BTU 09: 9K BTU 24: 24K BTU 12: 12K BTU 36: 36K BTU 15: 15K BTU 48: 36K BTU 18: 18K BTU Voltage 1: 115V 2: 208/230V 3036: Adjustable Capacity 30K or 36K BTU (No Impact on UPC Code, Subject to change without notice) Quick Reference Guide Indoor/Outdoor Compatibility Charts Highwall Compatibility TEMPO OUTDOOR UNITS ADVANCED PLUS ARCTIC FLEXFIT PRO ARCTIC MULTI FLEXFIT MULTI CONTROLLERS* 1U09TE1VHA 1U12TE1VHA 1U09TE2VHA 1U09TE2HDA 1U12TE2VHA 1U12TE2HDA 1U18TE2VHA 1U18TE2HDA 1U24TE2VHA 1U24TE2HDA 1U24TL2HFA 1U3036TL2HFA 1U09AP2VHA 1U12AP2VHA 1U15AP2VHA 1U18AP2VHA 1U24AP2VHA 1U09EH2VHE 1U12EH2VHE 1U18EH2VHE 1U24LP2HDA 1U3036LP2HDA 1U4248LP2HDA 1U24LP2VHA 1U36LP2VHA 1U48LP2VHA 2U20EH2HDA 3U24EH2HDA 4U36EH2HDA 2U18MS2HDA 3U24MS2HDA 4U36MS2HDA 5U42MS2HDA WJ01X24721 WJ26X27153 YR-HBS01 UCT30RWA YR-E16B YR-E17 QACT17A INDOOR HIGHWALL UNITS AW09TE1VHA ü AW12TE1VHA ü AW09TE2VHA ü AW12TE2VHA ü AW18TE2VHA ü AW24TE2VHA ü AW24TL2HFA ü ü AW30TL2HFA ü ü AW36TL2HFA ü ü AW09ES2VHB ü AW12ES2VHB ü AW15ES2VHB ü AW18ES2VHB ü AW24ES2VHB ü AW09EH2VHD ü AW12EH2VHD ü AW18EH2VHD ü AW07TC2HDA AW09TC2HDA ü AW12TC2HDA ü AW18TC2HDA ü AW24TC2HDA ü AW24LP2VHA ü AW36LP2VHA ü l l l l l l l l l l l l l l l l l üüüüüüü l üüüüüüü l üüüüüüü l üü üüü l ü üü l l l ¡¤¤¤ ¡¤¤¤ ¡¤¤¤ ¡¤¤¤ ¡¤¤¤ ¡¤¤¤ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡¤¤¤ ¡¤¤¤ ¡¤¤¤ ¡¤¤¤ ¡¤¤¤ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡¤¤¤ ¡¤¤¤ * l =Standard Controller. ¡= Optional Controller. ¤= Optional Controller requires WK-B adapter. Remote controllers WJ01X24721 and WJ26X27153 are shipped with indoor unit. Quick Reference Guide Indoor/Outdoor Compatibility Charts Cassette, Slim Duct, MSP Duct & Console Compatibility TEMPO OUTDOOR UNITS ADVANCED PLUS ARCTIC FLEXFIT PRO ARCTIC MULTI FLEXFIT MULTI CONTROLLERS* 1U09TE1VHA 1U12TE1VHA 1U09TE2VHA 1U09TE2HDA 1U12TE2VHA 1U12TE2HDA 1U18TE2VHA 1U18TE2HDA 1U24TE2VHA 1U24TE2HDA 1U24TL2HFA 1U3036TL2HFA 1U09AP2VHA 1U12AP2VHA 1U15AP2VHA 1U18AP2VHA 1U24AP2VHA 1U09EH2VHE 1U12EH2VHE 1U18EH2VHE 1U24LP2HDA 1U3036LP2HDA 1U4248LP2HDA 1U24LP2VHA 1U36LP2VHA 1U48LP2VHA 2U20EH2HDA 3U24EH2HDA 4U36EH2HDA 2U18MS2HDA 3U24MS2HDA 4U36MS2HDA 5U42MS2HDA WJ01X24721 WJ26X27153 YR-HBS01 UCT30RWA YR-E16B YR-E17 QACT17A AB09SC2VHA AB12SC2VHA AB18SC2VHA AL24LP2VHA AL36LP2VHA AL48LP2VHA USYL24UCDDA USYL30UCDDA USYL36UCDDA USYL42UCDDA USYL48UCDDA AD07SL2VHB AD09SL2VHB AD12SL2VHB AD18SL2VHB USYM09UCDSA USYM12UCDSA USYM18UCDSA USYM24UCDSA USYM24UCDDA USYM30UCDDA USYM36UCDDA USYM42UCDDA USYM48UCDDA AM36LP2VHA AM48LP2VHA USYF09UCDWA USYF12UCDWA USYF18UCDWA Pub No. 26-H2302 Rev. 05-30-23 ©Copyright 2023 GE Appliances, a Haier Company. Our continued commitment to quality products may mean a change in specifications without notice. INDOOR CASSETTE UNITS ü üüüüüüü l ü üüüüüüü l ü üü üüü l ü ü üü ü ü ü l ü l ü l ü l ü l INDOOR DUCTED UNITS ü ü ü ü ü ü ü ü üüüüüüü üüüüüüü üüüüüüü üü üüü üüüüüüü üüüüüüü üü üüü ü üü ü ü INDOOR CONSOLE UNITS ü ü ü üüüüüüü l üüüüüüü l üü üüü l ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ l ¡¡¡¡ l ¡¡¡¡ l ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ ¡l¡ ¡l¡ ¡l¡ ¡l¡ ¡¡¡ ¡¡¡ ¡¡¡ ¡¡¡ ¡¡¡ ¡¡¡ ¡¡¡ ¡¡¡ ¡¡¡ ¡l¡ ¡l¡ ¡¡¡¡ ¡¡¡¡ ¡¡¡¡ * l =Standard Controller. ¡= Optional Controller. ¤= Optional Controller requires WK-B adapter. Remote controllers WJ01X24721 and WJ26X27153 are shipped with indoor unit. MSP ducted units do not include controller. A controller must be ordered separately. Cassette does not ship with controller. Panel must be purchased separately and ships with controller.Adobe PDF Library 17.0 Adobe InDesign 18.2 (Windows)