User Manual for AXEON models including: 211470, Solo I Reverse Osmosis System
AXEON Solo I 50 GPD Reverse Osmosis System – Hubset Plus
File Info : application/pdf, 21 Pages, 1.42MB
DocumentDocumentPAGE TITLE HERE (LONG) MKT 590 A REVERSE OSMOSIS SYSTEM USER MANUAL Page 1 of 21 HEADER SECTION 2 TITLE HERE This page is Intentionally left blank MKT 590 A Page 2 of 21 TABLE OF CONTENTS Table of Contents INTRODUCTION .........................................................................................................................................4 SAFETY.........................................................................................................................................................5 PRECAUTIONARY STATEMENTS ......................................................................................................5 OPERATING DO'S AND DON'TS ............................................................................................................6 SYSTEM SPECIFICATION CHART.........................................................................................................7 OPERATING LIMITS ...............................................................................................................................7 FEEDWATER AND OPERATING SPECIFICATIONS ..........................................................................8 SOLO I COMPONENT IDENTIFICATION AND DESCRIPTION.........................................................9 PRE-FILTRATION................................................................................................................................. 10 POST-FILTRATION .............................................................................................................................. 10 TUBING AND LOCKING CLIPS KIT.................................................................................................. 10 PERMEATE STORAGE....................................................................................................................... 10 MEMBRANE INFORMATION ................................................................................................................. 11 MEMBRANE ELEMENT SPECIFICATIONS.................................................................................... 11 SYSTEM INSTALLATION ....................................................................................................................... 13 TOOLS AND EQUIPMENT REQUIRED FOR INSTALLATION .................................................... 13 FEED WATER CONNECTION ........................................................................................................... 13 FAUCET INSTALLATION .................................................................................................................... 14 PERMEATE (PRODUCT WATER) CONNECTION ........................................................................ 15 DRAIN SADDLE INSTALLATION ...................................................................................................... 15 AIR GAP CONNECTION ..................................................................................................................... 16 MEMBRANE INSTALLATION AND HANDLING................................................................................. 17 MEMBRANE INSTALLATION AND REPLACEMENT.................................................................... 17 SYSTEM PURGING AND INTIAL START UP..................................................................................... 18 TROUBLE SHOOTING............................................................................................................................ 19 TROUBLE SHOOTING CHART ......................................................................................................... 19 TECHNICAL ASSISTANCE ................................................................................................................ 19 SYSTEM WARRANTY............................................................................................................................. 20 MKT 590 A Page 3 of 21 INTRODUCTION The Solo I Reverse Osmosis System is a durable piece of equipment which, with proper care, will last for many years. This User Manual outlines installation, operation, maintenance and troubleshooting details vital to the sustained performance of your system. If your system is altered at the site of operation, or if the feedwater conditions change, please contact your local dealer or distributor to determine the proper recovery for your application. DO NOT UNDER ANY CIRCUMSTANCE REMOVE ANY CAUTION, WARNING, OR OTHER DESCRIPTIVE LABELS FROM THE SYSTEM. PRIOR TO OPERATING OR SERVICING THE REVERSE OSMOSIS SYSTEM, THIS USER'S MANUAL MUST BE READ AND FULLY UNDERSTOOD. KEEP THIS AND OTHER ASSOCIATED INFORMATION NEAR THE SYSTEM FOR FUTURE REFERENCE. MKT 590 A Page 4 of 21 SAFETY Defined below are the two safety headings used throughout this User Manual's text. WARNING: INDICATES STATEMENTS THAT ARE USED TO IDENTIFY DANGEROUS CONDITIONS OR PRACTICES. FAILURE TO FOLLOW WARNINGS COULD RESULT IN SERIOUS INJURY OR DEATH. CAUTION: INDICATES STATEMENTS THAT ARE USED TO IDENTIFY CONDITIONS OR PRACTICES THAT COULD RESULT IN EQUIPMENT OR OTHER PROPERTY DAMAGE STATEMENTS IN BOLD AND ALL CAPITALS ARE ADVISORY OR INFORMATIONAL STATEMENTS OF PARTICULAR IMPORTANCE TO THE HEADING UNDER WHICH THEY ARE FOUND. PRECAUTIONARY STATEMENTS DO NOT USE WHERE THE WATER IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM. ALWAYS SHUT OFF THE FEEDWATER, AND RELIEVE PRESSURE BEFORE WORKING ON THE UNIT. NEVER ALLOW THE UNIT TO FREEZE OR OPERATE WITH A FEEDWATER TEMPERATURE ABOVE 85°F. DO NOT PERMIT CHLORINE TO BE PRESENT IN THE FEED WATER. MKT 590 A Page 5 of 21 OPERATING DO'S AND DON'TS DO · Change the cartridge filters regularly. · Monitor the system and keep a daily log. · Run the system as much as possible on a continuous basis. DON'T · Permit chlorine to enter or be present in the feed water. · Shut down the system for extended periods. · Operate the system with insufficient feed flow or pressure. MKT 590 A Page 6 of 21 SOLO I SYSTEM SPECIFICATION CHART Nothing has a greater effect on a reverse osmosis system than the feed water quality. If your feed water conditions change, please contact your local dealer or distributor to determine the proper recovery for your application. Before starting the RO system it is strongly suggested to obtain an up to date water analysis of the water to be treated. IT IS VERY IMPORTANT TO MEET THE MINIMUM FEED WATER AND OPERATING REQUIREMENTS OUTLINED IN THIS MANUAL. FAILURE TO DO SO WILL CAUSE DAMAGE OR FAILURE OF THE SYSTEM COMPONENTS AND MEMBRANES. DAMAGE TO THE SYSTEM DUE TO OPERATION OUTSIDE OF THE SPECIFICATIONS OUTLINED IN THIS MANUAL WILL VOID THE MANUFACTURERS WARRANTY. OPERATING LIMITS* Design Temperature, °F Maximum Feed Temperature, °F Minimum Feed Temperature, °F 77 Maximum SDI Rating 85 Maximum Turbidity, NTU 40 Maximum Free Chlorine, ppm < 5 < 1 < 0.1 Maximum Ambient Temperature, °F 120 Maximum TDS, ppm 1000 Minimum Ambient Temperature, °F 40 Maximum Hardness, gpg 0 Maximum Feed Pressure, PSI 80 Maximum pH (continuous) 8 Minimum Feed Pressure, PSI 40 Minimum pH (continuous) 4 *If any of the feed water parameters are not within the limits given, consult your local dealer or distributor for assistance. Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions. HIGHER TDS AND/OR LOWER TEMPERATURES WILL REDUCE THE SYSTEM'S PRODUCT ION. MKT 590 A Page 7 of 21 FEEDWATER AND OPERATING SPECIFICATIONS MODELS SOLO I Flow Rates Permeate Flow Rate (gpd / lpd) Feedwater TDS m ax (ppm ) Product to Waste Ratio Connections Feed Perm eate Concentrate Mem brane Membrane Quantity Membrane Size Nom inal TDS Rejection % System Dimensions Approximate Dimensions L x W x H (in / cm) Approximate Weight (lbs / kg). 50 / 189 1000 1:2 1/4" QC 3/8" QC 1/4" QC 1 1812 96 16.5 x 11 x 15 / 41.91 x 27.94 x 38.10 15 / 7 Product flow and maximumrecovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate fl o w. Warranty Evaluation Test Conditions: Permeate flowrates and salt rejection based on the following test conditions 550 ppm, filtered and dechlorinated municipal tap water, 77°F / 25°C, 15% recovery, 7.0 pH and the specified operating pressure for membrane element type. Data taken after 60 minutes of operation. MKT 590 A Page 8 of 21 COMPONENT IDENTIFICATION ITEM NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PART NUMBER 200931 211623 201026 207797 211478 211663 211477 211479 211745 211481 200654 211482 207786 201028 211622 201018 200988 211456 DESCRIPTION PERMEATE STORAGE TANK PERMEATE STORAGE TANK VALVE PRODUCT WATER LINE TO TANK AND FAUCET (3/8" WHITE TUBING) 1/4" QUICK CONNECT LEAK DETECTOR 1/4" QUICK CONNECT FEED WATER ADAPTOR (FOR 3/8" WATER SUPPY LINE) FEED WATER LINE (1/4" BLUE TUBING) 5 MICRON SEDIMENT AND SINTERED CARBON BLOCK PRE FILTER SOLO I REVERSE OSMOSIS MEMBRANE ELEMENT SOLO I REVERSE OSMOSIS SYSTEM LID 3/8" QUICK CONNECT FITTING (1/4" MNPT THREAD) INLINE GRANULATED ACTIVATED CARBON POST FILTER 3/8" QUICK CONNECT FAUCET ADAPTOR CHROME FAUCET WITH AIR GAP CONNECTION AIR GAP DRAIN LINE (3/8" BLACK TUBING) 3/8" QUICK CONNECT DRAIN SADDLE SYSTEM DRAIN LINE FROM SYSTEM TO AIR GAP (1/4" BLACK TUBING) CONCENTRATE FLOW RESTRICTOR (INSTALLED INTO END OF TUBING) SOLO I REVERSE OSMOSIS SYSTEM MKT 590 A Page 9 of 21 COMPONENT IDENTIFICATION PRE-FILTRATION Solo I systems are supplied with an integrated 5 micron polyproylene sediment and sintered carbon filter (item 7, pg. 9). Change the filtration cartridge every 6 months. THE SYSTEM MUST BE OPERATED ON MUNICIPAL TAP WATER ONLY. POST-FILTRATION Solo I systems are supplied with an in-line granulated activated carbon post filter (item 11, pg. 9). Change the filtration cartridge every 6 - 12 months. TUBING AND LOCKING CLIPS KIT John Guest tubing and locking clips are provided for creating process connections and securing the quick connect collets. Locking clips are only to be used on John Guest branded fittings. PERMEATE STORAGE Solo I systems are supplied with a bladder storage tank (item 1, pg. 9). Tank storage capacity is dependenton feed pressure and tank pressure. Typical usable capacity ranges from 2.4 - 3.2 gallons. Ensure the tank pressure is kept around 7 psi, do not exceed 10 psi. MKT 590 A Page 10 of 21 MEMBRANE INFORMATION Solo I reverse osmosis systems come packaged with Solo Series Residential Membranes. General membrane element performance characteristics are listed on the following membrane specification chart. MEMBRANE ELEMENT SPECIFICATIONS Solo Series Residential Membranes (Standard) Membrane Type: Polyamide Thin Film Composite pH Range, Short Term Cleaning (30 Min.): 2 12 Maximum Operating Temperature: 113°F (45°C) Maximum Feed Silt Density Index (SDI): 5 Maximum Operating Pressure: 85 psi (5.86 bar) Chlorine Tolerance: 0 ppm pH Range, Continuous Operation*: 3 10 Product Specifications Dimension (inch / mm) Part Number Description Applied Pressure Permeate Flow psi / bar Rate gpd / lpd A B C D 211479 SOLO 1812 50 60 / 4.13 50 / 189.30 11.73 / 298.00 1.69 / 43.00 0.67 / 17.00 0.85 / 23.60 Warranty Evaluation Test Conditions: Permeate flowand salt rejection based on the following test conditions 550 ppm, filtered and dechlorinated municipal tap water, 77°F / 25°C, 15% recovery and the specified operating pressure. Minimum salt rejection is 96%. Permeate flows for warranty evaluation may vary +/20%. Maximum pressure drop at 10 psig / 0.69 bar. Under certain conditions, the presence of f ree chlorine, chloramines and other oxidizing agents will cause premature membrane f ailure. Since oxidation damage is not covered under warranty, the manuf acturer recommends removing all oxidizing agents by pretreatment prior to membrane exposure. Please contact the manuf acturer or your supplier f or more inf ormation. It is recommended that systems using these elements rinse the elements f or 24 hours, prior to f irst use, to meet NSF/ANSI 58 Standard. The f irst f ull tank of permeate must be discarded. Do not use this initial permeate f or drinking water or f ood preparation. Keep elements moist at all times af ter initial wetting. To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution. Rinse out the preservative bef ore use. For membrane warranty details, please contact the manuf acturer or your supplier f or more inf ormation. If operating limits and guidelines given in this product specif ication sheet are not strictly f ollowed, the warranty will be null and void. The customer is f ully responsible f or the ef f ects of incompatible chemicals and lubricants on elements. Use of any such chemicals or lubricants will void the warranty. These membranes may be subject to drinking water application restrictions in some countries: please check the application status bef ore use and sa hese elements have MKT 590 A Page 11 of 21 MEMBRANE INFORMATION not been through the French approval process f or use in potable water. The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens f rom water. Ef f ective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system. No f reedom f rom inf ringement of any patent owned by the manuf acturer or others is to be inf erred. Because use conditions and applicable laws may dif f er f rom one location to another and may change with time, customer is responsible f or determining whether products and the inf ormation in this document are appropriate f or customer's use and f or ensuring that customer's workplace and disposal practices are in compliance with applicable laws and other governmental enactments. The claims made may not have been approved f or use in all countries. The manuf acturer assumes no obligation or liability f or the inf ormation in this document. AXEON reserves the right to update this inf ormation periodically f or the purposes of quality and accuracy. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED MKT 590 A Page 12 of 21 SYSTEM INSTALLATION When choosing a location to install the system, select an area with enough room for service to be performed on the system. Do not install system in direct sunlight or subject the system to temperature extremes and/or excess humidity. Use a tube cutter for cutting the supplied tubing. These can be found in your local hardware store. TOOLS AND MATERIALS REQUIRED FOR INSTALLATION · Variable speed drill · Carbide grinding burr or f ile · 1/4" drill bit (f or making pilot holes) · Tubing cutter · 3/8" drill bit · Phillips screwdriver · 7/8" hole saw, or porcelain saw · Tef lon tape · Adjustable wrench · Protective eyewear · Tape measure The above tools and materials are available in any local hardware stores. If you are uncomfortable performing the installation please contact a local dealer or distributor for installation services. FEED WATER CONNECTION BEFORE BEGINNING THE INSTALLATION, PLAN OUT HOW THE SYSTEM IS TO BE PLACED UNDERNEATH THE SINK OR COUNTERTOP. THIS WILL HELP IN PLANNING WHAT LENGTHS OF TUBING TO USE FOR SYSTEM CONNECTIONS. · Locate the cold-water angle stop valve underneath the sink and turn it off. · Relieve the pressure by opening the cold-water line and disconnect the sink feed line. · Install the feedwater adapter (item 5, pg. 9) to the angle stop valve. · Insert the blue feed line tubing (item 6, pg. 9) into quick connect port of feed water adapter. · Connect the sink feed line to the feed water adapter. Make sure the feed water adapter is in the closed position and turn on the angle stop valve. · Connect the blue tubing to the inlet of the leak detector (item 4, pg. 9). Connect a section of tubing from the leak detector outlet to the system (item 18, pg. 9) inlet. Install the provided red locking clips. MKT 590 A Page 13 of 21 SYSTEM INSTALLATION · Use the provided double sided tape to attach the leak detector near the base of the system. Unwrap the provided compressed cloth and insert into the leak detector. Close the leak detector. FAUCET INSTALLATION INSTALLATION OF THIS FAUCET REQUIRES A 7/8" OPENING IN THE SINK OR COUNTERTOP.EXTREME CARE MUST BE TAKEN IN DRILLING THE HOLE FOR THE FAUCET. THE SURFACE OF MOST SINKS IS EXTREMELY HARD AND BRITTLE AND CAN EASILY BE CHIPPED OR CRACKED. IF YOU ARE UNCOMFORTABLE PERFORMING THIS PROCEDURE, PLEASE CONTACT YOUR LOCAL DISTRIBUTOR FOR INSTALLATION ASSISTANCE. · Locate the faucet (item 13, pg 9) and remove the contents from the packaging. · Place the trim plate (escutcheon) over the faucet shank followed by the rubber washer. · Insert the faucet shank through the provided hole with only the hardware described in the previous steps. · From underneath the sink,slide the plastic spacer onto the shank of the faucet and start the nut. Tighten until there is still enough room to slide the rubber and metal split washers between the spacer and the underside of the sink. Please note that the spacer has a flat spot in order to clear the barbs for the air gap drain. · Slide the rubber and metal split washers onto the shank.Ensure the rubber split washer is in contact with the underneath surface of the sink or countertop. · Tighten the nut. · Locate the faucet adaptor (item 12, pg. 9) and thread it on to the faucet shank hand tight. Once hand tight, tighten an additional 1/4 turn. MKT 590 A Page 14 of 21 SYSTEM INSTALLATION PERMEATE (PRODUCT WATER) CONNECTION · Apply 3 4 wraps of Teflon tape to the threads of both 3/8" fittings (item 10, pg. 9) and install onto the inline filter. · Cut a section of white 3/8" tubing (item 3, pg. 9) approximately 18 to 36 inches and connect the water filter to the system inline filter connection. Use the remaining 3/8" tubing to connect the inline filter (item 11, pg. 9) to the faucet (item 13, pg. 9) using the faucet adapter (item 12, pg. 9). Install the supplied red locking clips on the fittings. FROM SYSTEM TO FAUCET · Apply 6 8 wraps of Teflon tape to the threaded stem on the top of the tank (item 1, pg. 9). Install tank valve (item 2, pg. 9) to the top of the tank.This only needs to be installed hand tight. Connect the tank valve to the system tank connection. · Using the provided white 3/8" tubing. Install supplied red locking clips on the fittings. DRAIN SADDLE INSTALLATION · Obtain the drain saddle assembly (item 15, pg. 9). Put the adhesive backed foam on the inside of the connection point of the drain saddle. Ensure the holes are aligned. Position the drain saddle on the sink drainpipe between the sink drain and the P trap. · Once in position, mark where the hole is to be drilled. Remove the drain saddle and drill the 3/8" hole into the drainpipe. · Align the drain saddle with the hole and secure it with the provided bolts. MKT 590 A Page 15 of 21 SYSTEM INSTALLATION AIR GAP CONNECTION · Insert the 3/8" drain line (item 14, pg. 9) into the drain saddle and press the other end onto the large (brine outlet) barb on the faucet air gap. Ensure there are no dips or low points in the tubing from the faucet to the drain saddle. Trim accordingly. · Obtain the black 1/4" tubing (item 16, pg. 9) and measure the length required to connect the system outlet to the brine inlet on the faucet air gap. · Install the provided capillary flow restrictor (item 17, pg. 9) into the open end of the tubing. · Firmly press the tubing into the drain port of the system. Press the opposite end onto the brine inlet of the faucet air gap. ANY RESTRICTIONS OR BLOCKAGE IN THE DRAIN LINE CAN CAUSE BACKPRESSURE, WHICH WILL INCREASE THE SYSTEM'S OPERATING PRESSURE. THIS CAN RESULT IN DAMAGE TO THE SYSTEM'S MEMBRANES AND COMPONENTS. MKT 590 A Page 16 of 21 MEMBRANE INSTALLATION AND HANDLING FEED WATER ADAPTOR VALVE MUST BE IN THE CLOSED POSITION BEFORE REPLACING THE MEMBRANE ELEMENT. MEMBRANE INSTALLATION / REPLACEMENT 1. Use the provided wrench to remove the black top cap (item 9, pg. 9) to the system. Remove the 2-stage filter (item 7, pg. 9) from the system and remove the plastic film wrap. 2. Obtain the membrane (item 8, pg. 9) and remove it from its packaging. Insert the membrane down into the filter cartridge while twisting (O-rings up as shown). Ensure the membrane is fully inserted into the filter. 3. Place the filter and membrane into the system base. 4. Replace the system cap and tighten with the provided wrench. 5. Once installed, use the calendar wheel on the cap to note the date of installation. This will help to identify when it is time to replace the filter and membrane. 6. To startup the system, please refer to the System Purging/Initial StartUp section of this User's Manual. MKT 590 A Page 17 of 21 SYSTEM PURGING AND INITIAL START UP CAREFULLY INSPECT YOUR SYSTEM BEFORE INITIAL START UP. CHECK THAT ALL THE PLUMBING CONNECTIONS ARE IN PLACE AND SECURELY FASTENED. ENSURE THAT THERE ARE NO KINKS OR TWISTS IN THE LINES. 1. Double check that all connections are made and the tubing is in securely. 2. Make sure the tank valve is open. 3. Make sure the lever on the leak detector is in the down position. 4. Flip the faucet lever up to allow for continuous flow. 5. Slowly turn on the feed valve 1/4 turn, observe for any leaks. 6. If no leaks are present, fully open the feed valve. 7. Continue to check for any leaks. 8. Allow the system to drain the permeate for the first hour of operation. 9. Please allow for the tank to fill 3 4 times before drinking the product water. 10. After completely draining the tank 3 4 times you may begin to use the water for consumption. MKT 590 A Page 18 of 21 TROUBLESHOOTING TROUBLE SHOOTING CHART SYMPTOMS Not Producing Water Low Permeate Flow (From Faucet) Tank Filling Slowly Poor permeate quality Leaking Fittings & Tubing Connections POSSIBLE CAUSES CORRECTIVE ACTION Feed valve is closed Leak detector has engaged Im proper filter cartridge installation Open the feed valve. Inspect for leaks. If a leak is present, determine the location of the leak and repair as needed. Replace the textile in the leak detector with a new one. If no leak is present, close the lever on the leak detector. Inspect and re-install filter cartridge. Incorrect tubing connections Confirm the connection points to m atch the diagram . Kinked tubing Replace the kinked section of tubing. Tank air pressure is low Ensure pressure is approxim ately 7 PSI. Do not exceed 10 PSI. Tank valve not fully open Open tank valve fully. Line to faucet is kinked Replace the kinked section of tubing. Low feed pressure Confirm feed pressure pressure and adjust regulator as needed. Feed valve not fully open Fully open the feed valve. Kinked tubing Replace the kinked section of tubing. Exhausted filter and or mem brane Replace filter / m em brane as needed. Insufficient flushing of tank/membrane Flush tank with 2-3 fills of permeate water. Membrane/filter cartridge exhausted Replace membrane / filter. Tubing not pressed into fitting securely Remove tubing and re-insert ensuring the tubing bottoms out. Insufficient teflon tape Rem ove existing teflon tape and reapply with an additional wrap. Inproper installation of teflon tape Poorly cut or gouged tubing Remove teflon tape. Ensure to wrap in a clockwise rotation. Remove tubing from fitting. Check to see that the tubing was cut perpindicular and that there are no scratches on the tubing. If the tubing was not cut properly or scratched, make a new cut approximately 1/2" back. TECHNICAL ASSISTANCE If technical assistance is required: Contact your local dealer or distributor Prior to making the call, have the following information available: System installation date Serial number Detailed description of the problem MKT 590 A Page 19 of 21 SYSTEM WARRANTY ONE YEAR LIMITED WARRANTY Warranty Terms Subject to the terms and conditions set f orth hereinaf ter, the manuf acturer (hereaf ter "Manuf acturer") warrants to the original purchaser (hereaf ter the "Customer") that the systems and products manuf actured by the Manuf acturer are f ree f rom def ects in material and in workmanship f or twelve (12) months f rom the Warranty Commencement Date (as def ined below) only when used strictly in accordance with the applicable operating instructions and within the range of the operating conditions specif ied by the Manuf acturer f or each such product. This Warranty does not extend to systems, equipment, or components manuf actured by others, nor to systems, equipment, or components manuf actured by others and distributed by the Manuf acturer. This Warranty does not extend to equipment or components manuf actured by others which have been incorporated into a Manuf acturer product but, if allowable the, Manuf acturer hereby assigns, without warranty, to the Customer its interest, if any, under any Warranty made by the Manuf acturer of such equipment or component. This Warranty does not cover disposable items such as f uses, Orings, regeneration materials/chemicals, or other such disposable items, which must be replaced periodically under the normal and f oreseeable operating conditions of the goods warranted hereby. Warranty Commencement Date The Warranty Commencement Date f or each Manuf acturer product shall be the later of the date of : (1) receipt by the Customer, or (2) the date of installation at the Customer's premises provided that such installation must occur within three (3) months of shipment f rom the Manuf acturer's manuf acturing f acility. In no event shall the Warranty Commencement Date exceed three (3) months f rom the shipment f rom the Manuf acturer's manuf acturing f acility. The Customer shall provide proof of purchase in order to exercise rights granted under this Warranty. If requested by the Manuf acturer, the Customer must also provide proof of the installation date. Warranty Service THE MANUFACTURER'S OBLIGATION UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT (AT MANUFACTURER'S SOLE DISCRETION) OF ANY PRODUCT, OR COMPONE NT THEREOF, PROVED TO BE DEFECTIVE IN MATERIAL OR WORKMANSHIP WITHIN THE COVERED WARRANTY PERIOD. The Customer, at the Customer's risk and expense, shall be responsible f or returning such product or component, only af ter obtaining a Return Goods Authorization (RGA) number f rom the Manuf acturer, arranging f or f reight prepaid, and in conf ormance with any special packaging and shipping instructions set f orth on the operation documentation or RGA instructions, or as otherwise reasonably required, to the Manuf acturer, together with (1) RGA number issued by the Manuf acturer at Customer's request; (2) proof of purchase and, if necessary, proof of installation date; (3) a Return Goods Authorization Form; (4) a description of the suspected def ects; (5) the serial number of the Manuf acturer product alleged to be def ective; (6) a description of the type of water and pretreatment equipment which has been utilized in connection with the product, if any. The Manuf acturer shall, in the Manuf acturer's reasonable discretion, be the sole judge of whether a returned product or component is def ective in material or workmanship. Required or replaced products or components shall be returned surf ace f reight. In genuine emergency situations, the Manuf acturer will (at the Manuf acturer's sole discretion) f orward replacement parts to the Customer without waiting f or authorized return of the questionable part(s). In such cases, Customer will issue a purchase order or other payment guarantee prior to shipment. If the returned part is f ound to have been misused or abused, or the def ective part is not received by the Manuf acturer within thirty (30) days; the Customer will be invoiced f or the replacement part(s) provided. This Warranty does not cover or include labor and/or travel to the Customer's premise or location or any other location. Charges of $1000 per day plus associated travel expenses will be incurred by the Customer in providing the Warranty Service at any location other than the Manuf acturer's main headquarters; that is if the Manuf acturer deems that the product is not covered by said Warranty. The Manuf acturer reserves the right to precondition such travel to Customer's premises upon prepayment of the Manuf acturer's anticipated costs of attending such premises. MKT 590 A Page 20 of 21 SYSTEM WARRANTY ONE YEAR LIMITED WARRANTY Voidability of Warranty This Warranty shall be void and unenf orceable as to any Manuf acturer product which has been damaged by accident, mishandling, abuse or has been repaired, modif ied, altered, disassembled or otherwise tampered with by anyone other than the Manuf acturer or an authorized Manuf acturer service representative; or, if any replacement parts are not authorized by the Manuf acturer have been used, or, the product has not been installed, operated and maintained in strict accordance and adherence with the operating documentation and manuals f or such product. Any expressed Warranty, or similar representation of perf ormance set f orth in the operation documentation f or media or resin incorporated into the Manuf acturer product shall be void and unenf orceable unless the f eed water requirements set f orth in the operating documentation f or such product are unequivocally and strictly adhered to. Limitations and Exclusions THIS WARRANTY AND REMEDIES DESCRIBED HEREIN AND HEREINABOVE ARE EXCLUSIVE AND IN LIEU OF ANY AND ALL OTHER WARRANTY OR REMEDIES, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL OR OTHE R SIMILAR TYPES OF DAMAGES, DAMAGES FOR THE LOSS OF PRODUCTION OR PROFITS, OR INJURY TO PERSON OR PROPERTY. NO PERSON HAS ANY AUTHORITY TO BIND THE MANUFACTURER TO OTHE R THAN WHAT IS SET FORTH ABOVE. THIS WARRANTY GIVES THE CUSTOMER SPECIFIC LEGAL RIGHTS AND THE CUSTOMER MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM JURISDICTION TO JURISDICTION. THE PARTIES RECOGNIZE AND AGREE, THAT IN ALL RESPECTS THE LAWS OF THE STATE OF CALIFORNIA SHALL APPLY TO AND SHALL GOVERN ANY INTERPRETATION OR LEGAL SIGNIFICANCE OF THIS DOCUMENT. NO WARRANTY OR OTHER LIABILITY OF THE MANUFACTURER TO CUSTOMER UNDER THIS AGREEMENT OR OTHERWISE WILL IN ANY EVENT EXCEED THE COST OF REPLACEMENT OF THE APPLICABLE MANUFACTURER PRODUCT, PART, OR ACCESSORY THAT IS SUBJECT TO ANY BREACH OF THE MANUFACTURER'S WARRANTY. THE MANUFACTURER WILL NOT BE LIABLE FOR ANY DAMAGE TO ANY PROPERTY OF CUSTOMER OR TO CUSTOMER'S CUSTOMERS FOR ANY CONSEQUENTIAL, INCIDENTA L, OR ECONOMIC LOSS OR COMMERCIAL DAMAGE WHATSOEVER. REMEDIES HEREIN PROVIDED ARE EXPRESSLY MADE THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF ANY WARRANTY OR OTHE R OBLIGATION HEREUNDER EXPRESS OR IMPLIED OR FROM THE OPERATION OF LAW. MKT 590 A Page 21 of 21MONSTERS Unlimited Adobe PDF Library 20.13.106