Wolf Design Guide
D5ff4df6e2842c Design Guide
REVISED 12/2020
Design Guide
2 | Wolf Customer Care 800.222.7820
Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.
Throughout this guide, dimensions may vary by ± 1/8" (3). Dimensions in parentheses are millimeters unless otherwise specified.
Contents
Contents
4 M Series Ovens 16 E Series Ovens 26 L Series Oven 30 Convection Steam Ovens 36 Speed Ovens 42 Microwave Ovens 56 Warming Drawers 62 Induction/Electric Cooktops 70 Gas Cooktops 76 Module Cooktops 86 Coffee System 92 Cup Warming Drawer 96 Vacuum Seal Drawer 102 Dual Fuel Ranges 106 Gas Ranges 110 Induction Ranges 114 Sealed Burner Rangetops 118 Outdoor Grills/Modules 130 Cooktop Ventilation Hoods 142 Downdraft Ventilation 148 Pro Ventilation Hoods 158 Wolf Warranty
wolfappliance.com|3
M Series Ovens
M Series Built-In Ovens
Contemporary M series ovens include stainless steel and black glass models. Superior performance features include a more advanced dual vertical convection fan system, touchscreen controls, convenient preset cooking programs, and improved interior lighting. There is more usable space inside for deliciousness on a grand scale. M series ovens can be installed in a standard or flush inset application.
M SERIES OVENS TRANSITIONAL
SO30TM/S/TH
PROFESSIONAL
DO30TM/S/TH
UPPER OVEN
LOWER OVEN
SO30PM/S/PH
CONTEMPORARY
DO30PM/S/PH
SO30CM/S
SO30CM/B
DO30CM/S
DO30CM/B
4 | Wolf Customer Care 800.222.7820
M Series Ovens
30" M Series Built-In Ovens
TRANSITIONAL SINGLE OVEN
7/8"
85/8"
(22)
(218)
281/2"
(723)
2" (51)
13/8" (36)
CONDUIT CHANNEL
27"
(686)
297/8" (759)
21/2"
(65)
23" (584)
BEHIND FRAME
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
TRANSITIONAL DOUBLE OVEN
7/8"
(22)
85/8"
(218)
2" (51)
13/8" (36)
CONDUIT CHANNEL
507/8"
(1291)
493/8"
(1254)
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
297/8" (759)
21/2"
(65)
23" (584)
BEHIND FRAME
wolfappliance.com|5
M Series Ovens
30" M Series Built-In Ovens
PROFESSIONAL SINGLE OVEN
7/8"
85/8"
(22)
(218)
281/2"
(723)
2" (51)
13/8" (36)
CONDUIT CHANNEL
27"
(686)
297/8" (759)
31/4"
(83)
23" (584)
BEHIND FRAME
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
PROFESSIONAL DOUBLE OVEN
UPPER OVEN
LOWER OVEN
7/8"
85/8"
(22)
(218)
2" (51)
13/8" (36)
CONDUIT CHANNEL
507/8"
(1291)
493/8"
(1254)
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
297/8" (759)
31/4"
(83)
23" (584)
BEHIND FRAME
6 | Wolf Customer Care 800.222.7820
M Series Ovens
30" M Series Built-In Ovens
CONTEMPORARY STAINLESS STEEL SINGLE OVEN
7/8"
85/8"
(22)
(218)
281/2"
(723)
2" (51)
13/8" (36)
CONDUIT CHANNEL
27"
(686)
297/8" (759)
23" (584)
BEHIND FRAME
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
CONTEMPORARY STAINLESS STEEL DOUBLE OVEN
7/8"
85/8"
(22)
(218)
2" (51)
13/8" (36)
CONDUIT CHANNEL
507/8"
(1291)
493/8"
(1254)
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
297/8" (759)
23" (584)
BEHIND FRAME
wolfappliance.com|7
M Series Ovens
30" M Series Built-In Ovens
CONTEMPORARY BLACK GLASS SINGLE OVEN
1"
85/8"
(25)
(218)
281/2"
(723)
2" (51)
13/8" (36)
CONDUIT CHANNEL
27"
(686)
297/8" (759)
23" (584)
BEHIND FRAME
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
CONTEMPORARY BLACK GLASS DOUBLE OVEN
1"
85/8"
(25)
(218)
2" (51)
13/8" (36)
CONDUIT CHANNEL
507/8"
(1291)
493/8"
(1254)
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
297/8" (759)
23" (584)
BEHIND FRAME
8 | Wolf Customer Care 800.222.7820
M Series Ovens
Planning Information
The M series oven can be installed in a standard or flush inset application. If a cooktop is installed above an oven, a minimum of 1/4" (6) is required between the units. The location of the electrical supply within the oven opening may require additional cabinet depth.
Finish the edges of the opening. They may be visible when the door is open.
For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT Single Oven Double Oven
TRIM OVERLAP Top Bottom Sides
MIN 250 lb (115 kg) 400 lb (181 kg)
1" (25) 0" (0) 11/16" (18)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes. Locate the electrical supply flush with the back wall and within the shaded area shown in the illustrations on the following pages. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit.
Performance may be compromised if the electrical supply is less than 240 volts.
The oven is supplied with a conduit consisting of two insulated hot lead conductors and a bare ground conductor. The wiring diagram covering the control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS--SINGLE OVEN
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
30 amp dedicated circuit
Conduit
4' (1.2 m)
Total Amps
22
Max Connected Load
5.4 kW
DUAL INSTALLATION
Two M series single ovens can be installed side by side in a standard or flush inset application. A dual installation kit is required. To maintain appropriate airflow, the ovens must be installed into one opening. Any cosmetic or structural material placed between the ovens will impede airflow and is not recommended. Refer to the illustrations on pages 1415.
The dual installation kit is available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
ELECTRICAL REQUIREMENTS--DOUBLE OVEN
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
50 amp dedicated circuit
Conduit
5' (1.5 m)
Total Amps
45
Max Connected Load
10.8 kW
wolfappliance.com|9
M Series Ovens
30" M Series Single Oven
STANDARD INSTALLATION
271/2"
(699) OPENING HEIGHT
231/4" (591)
OPENING DEPTH
TOP VIEW
5"
(127)
E
4"
(102)
281/2" (724)
OPENING WIDTH
E E
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
10 | Wolf Customer Care 800.222.7820
M Series Ovens
30" M Series Single Oven
FLUSH INSET INSTALLATION
283/4"
(730) FLUSH INSET
HEIGHT***
7/8" (22)
OR
1" (25)**
24" (610)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
301/8" (765)
FLUSH INSET WIDTH***
11/8" (29)
5"
(127)
E
4"
(102)
13/16" (21)
E
1/8" (3)
E
SIDE VIEW
FRONT VIEW
*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry. ** 7/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model. ***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
wolfappliance.com|11
M Series Ovens
30" M Series Double Oven
STANDARD INSTALLATION
231/4" (591)
OPENING DEPTH
TOP VIEW
497/8"
(1267) OPENING HEIGHT
5"
(127)
E
4"
(102)
281/2" (724)
OPENING WIDTH
17" (432)
TYPICAL
E E
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
12 | Wolf Customer Care 800.222.7820
M Series Ovens
30" M Series Double Oven
FLUSH INSET INSTALLATION
511/8"
(1299) FLUSH INSET
HEIGHT***
7/8" (22)
OR
1" (25)**
24" (610)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
301/8" (765)
FLUSH INSET WIDTH***
11/8" (29)
5"
(127)
E
4"
(102)
17" (432)
TYPICAL
13/16" (21)
E
1/8" (3)
E
SIDE VIEW
FRONT VIEW
*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry. ** 7/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model. ***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
wolfappliance.com|13
M Series Ovens
30" M Series Single Oven
DUAL STANDARD INSTALLATION
271/2"
(699) OPENING HEIGHT
TOP VIEW
231/4" (591)
OPENING DEPTH
5"
(127)
E
4"
(102)
581/2" (1486)
OPENING WIDTH
5"
(127)
E
4"
(102)
E
E
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
14 | Wolf Customer Care 800.222.7820
M Series Ovens
30" M Series Single Oven
DUAL FLUSH INSET INSTALLATION
283/4"
(730) FLUSH INSET
HEIGHT***
7/8" (22)
OR
1" (25)**
TOP VIEW
24" (610)
FLUSH INSET DEPTH
FINISHED CLEATS*
601/8" (1527)
FLUSH INSET WIDTH***
11/8" (29)
5"
(127)
E
4"
(102)
5"
(127)
E
4"
(102)
13/16" (21)
1/8" (3)
E
E
SIDE VIEW
FRONT VIEW
*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry. ** 7/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model. ***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
wolfappliance.com|15
E Series Ovens
E Series Built-In Ovens
The Wolf E Series convection oven has two fans and four heating elements. Ten cooking modes allow you to select the one precisely suited to the dish you're preparing. The oven is selfcleaning. E series ovens are crafted of stainless steel. The handles match the rest of the Wolf cooking appliance offering, providing a more cohesive look. E series ovens can be installed in a standard or flush inset application.
E SERIES OVENS TRANSITIONAL
SO3050TE/S/TH PROFESSIONAL
DO3050TE/S/TH
SO3050PE/S/PH
DO3050PE/S/PH
16 | Wolf Customer Care 800.222.7820
E Series Ovens
30" E Series Built-In Ovens
TRANSITIONAL SINGLE OVEN
7/8"
85/8"
(22)
(218)
281/2"
(723)
2" (51)
13/8" (36)
CONDUIT CHANNEL
27"
(686)
297/8" (759)
21/2"
(65)
23" (584)
BEHIND FRAME
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
TRANSITIONAL DOUBLE OVEN
7/8"
(22)
85/8"
(218)
2" (51)
13/8" (36)
CONDUIT CHANNEL
507/8"
(1291)
493/8"
(1254)
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
297/8" (759)
21/2"
(65)
23" (584)
BEHIND FRAME
wolfappliance.com|17
E Series Ovens
30" E Series Built-In Ovens
PROFESSIONAL SINGLE OVEN
7/8"
85/8"
(22)
(218)
281/2"
(723)
2" (51)
13/8" (36)
CONDUIT CHANNEL
27"
(686)
297/8" (759)
33/8"
(86)
23" (584)
BEHIND FRAME
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
PROFESSIONAL DOUBLE OVEN
7/8"
(22)
85/8"
(218)
2" (51)
13/8" (36)
CONDUIT CHANNEL
507/8"
(1291)
493/8"
(1254)
17/8"
(46)
281/2"
(724)
OPEN OVEN DOOR
213/8"
(543)
297/8" (759)
33/8"
(86)
23" (584)
BEHIND FRAME
18 | Wolf Customer Care 800.222.7820
E Series Ovens
Planning Information
The E series oven can be installed in a standard or flush inset application. If a cooktop is installed above an oven, a minimum of 1/4" (6) is required between the units. The location of the electrical supply within the oven opening may require additional cabinet depth.
Finish the edges of the opening. They may be visible when the door is open.
For standard installations, the face trim overlaps stiles and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT Single Oven Double Oven
TRIM OVERLAP Top Bottom Sides
MIN 250 lb (115 kg) 400 lb (181 kg)
1" (25) 0" (0) 11/16" (18)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes. Locate the electrical supply flush with the back wall and within the shaded area shown in the illustrations on the following pages. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit.
Performance may be compromised if the electrical supply is less than 240 volts.
The oven is supplied with a conduit consisting of two insulated hot lead conductors and a bare ground conductor. The wiring diagram covering the control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS--SINGLE OVEN
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
30 amp dedicated circuit
Conduit
4' (1.2 m)
Total Amps
22
Max Connected Load
5.4 kW
DUAL INSTALLATION
Two E series single ovens can be installed side by side in a standard or flush inset application. A dual installation kit is required. To maintain appropriate airflow, the ovens must be installed into one opening. Any cosmetic or structural material placed between the ovens will impede airflow and is not recommended. Refer to the illustrations on the following pages.
The dual installation kit is available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
ELECTRICAL REQUIREMENTS--DOUBLE OVEN
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
50 amp dedicated circuit
Conduit
5' (1.5 m)
Total Amps
45
Max Connected Load
10.8 kW
wolfappliance.com|19
E Series Ovens
30" E Series Single Oven
STANDARD INSTALLATION
271/2"
(699) OPENING HEIGHT
231/4" (591)
OPENING DEPTH
TOP VIEW
5"
(127)
E
4"
(102)
281/2" (724)
OPENING WIDTH
E E
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
20 | Wolf Customer Care 800.222.7820
E Series Ovens
30" E Series Single Oven
FLUSH INSET INSTALLATION
283/4"
(730) FLUSH INSET
HEIGHT**
7/8" (22)
24" (610)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
301/8" (765)
FLUSH INSET WIDTH**
11/8" (29)
5"
(127)
E
4"
(102)
13/16" (21)
E
1/8" (3)
E
SIDE VIEW
FRONT VIEW
*Shaded areas will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
wolfappliance.com|21
E Series Ovens
30" E Series Double Oven
STANDARD INSTALLATION
231/4" (591)
OPENING DEPTH
TOP VIEW
497/8"
(1267) OPENING HEIGHT
5"
(127)
E
4"
(102)
281/2" (724)
OPENING WIDTH
17" (432)
TYPICAL
E E
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
22 | Wolf Customer Care 800.222.7820
E Series Ovens
30" E Series Double Oven
FLUSH INSET INSTALLATION
511/8"
(1299) FLUSH INSET
HEIGHT**
7/8" (22)
24" (610)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
301/8" (765)
FLUSH INSET WIDTH**
11/8" (29)
5"
(127)
E
4"
(102)
17" (432)
TYPICAL
13/16" (21)
E
1/8" (3)
E
SIDE VIEW
FRONT VIEW
*Shaded areas will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
wolfappliance.com|23
E Series Ovens
30" E Series Single Oven
DUAL STANDARD INSTALLATION
271/2"
(699) OPENING HEIGHT
TOP VIEW
231/4" (591)
OPENING DEPTH
5"
(127)
E
4"
(102)
581/2" (1486)
OPENING WIDTH
5"
(127)
E
4"
(102)
E
E
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
24 | Wolf Customer Care 800.222.7820
E Series Ovens
30" E Series Single Oven
DUAL FLUSH INSET INSTALLATION
283/4"
(730) FLUSH INSET
HEIGHT**
7/8" (22)
TOP VIEW
24" (610)
FLUSH INSET DEPTH
FINISHED CLEATS*
601/8" (1527)
FLUSH INSET WIDTH**
11/8" (29)
5"
(127)
E
4"
(102)
5"
(127)
E
4"
(102)
13/16" (21)
1/8" (3)
E
E
SIDE VIEW
FRONT VIEW
*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry. ** Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
wolfappliance.com|25
L Series Oven
L Series Built-In Oven
Since their introduction, Wolf L series built-in ovens have taken the culinary world by storm-- and not just for their stylish cobalt blue interior and 10 cooking modes. Thanks to a Wolf innovation called dual convection, the L series delivers faster, more consistent results for baking, roasting, broiling--even drying fruits. The Wolf L series oven is offered in the 36" width with unframed door style and tubular handle.
L SERIES OVEN UNFRAMED
SO36U/S
26 | Wolf Customer Care 800.222.7820
L Series Oven
L Series Built-In Oven
DIMENSIONS
24 3/8"
(619)
3" (76)
CONDUIT CHANNEL
23"
(584)
35 5/8"
(905)
3"
24" (610)
(76)
BEHIND FRAME
8 7/8"
(225)
9 5/8"
(244)
341/8"
(867)
OPEN OVEN DOOR
17 3/4"
(451)
wolfappliance.com|27
L Series Oven
Planning Information
If a cooktop is being installed above an oven, a minimum of 1/4" (6) is required between the units. The location of the electrical supply within the oven opening may require additional cabinet depth.
Finish the edges of the opening. They may be visible when the door is open.
For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
INSTALLATION REQUIREMENTS
BASE SUPPORT 36" Single Oven
TRIM OVERLAP Top Bottom Sides
MIN 250 lb (113 kg)
3/16" (5) 1/8" (3) 9/16" (14)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and within the shaded area shown in the illustration on the following page. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit.
Performance may be compromised if the electrical supply is less than 240 volts.
The oven is supplied with a conduit consisting of two insulated hot lead conductors and a bare ground conductor. The wiring diagram covering the control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
30 amp dedicated circuit
Conduit
3' (.9 m)
Total Amps
21
Max Connected Load
5.1 kW
28 | Wolf Customer Care 800.222.7820
L Series Oven
36" L Series Single Oven
STANDARD INSTALLATION
241/16"
(611) OPENING HEIGHT
24" (610)
OPENING DEPTH
TOP VIEW
5"
(127)
E
4"
(102)
341/2" (876)
OPENING WIDTH
E
E
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
wolfappliance.com|29
Convection Steam Ovens
Convection Steam Ovens
The legacy of the "combination oven" goes back decades, to innovative chefs in America and Europe who embraced the combination of air movement with superheated steam to achieve superior results--from breads and roasts to delicate fishes, seafood, and vegetables. Wolf combines the benefits of convection and steam for the most innovative steam oven on the market today. Virtually any dish prepared in a conventional oven, range, or microwave can also be prepared in the Wolf convection steam oven--with more control. Two widths and three distinct styles compliment the look of Wolf ovens, ranges, and cooktops. Convection steam ovens can be installed in a standard or flush inset application.
CONVECTION STEAM OVENS TRANSITIONAL
CSO24TE/S/TH PROFESSIONAL
CSO30TM/S/TH
CSO30TE/S/TH
CSO30PM/S/PH CONTEMPORARY
CSO30PE/S/PH
CSO30CM/B/TH
CSO30CMS
CSO30CMB
30 | Wolf Customer Care 800.222.7820
Convection Steam Ovens
Convection Steam Ovens
TRANSITIONAL
7/8"
(22)
177/8"
(454)
171/2"
(446)
W
WIDTH
21/2"
(64)
211/2" (546)
BEHIND FRAME
WIDTH 24" Transitional 30" Transitional
W 231/2" (597) 297/8" (759)
213/16"
(538)
OPEN OVEN DOOR
143/16"
(360)
wolfappliance.com|31
Convection Steam Ovens
Convection Steam Ovens
PROFESSIONAL
7/8"
(22)
177/8"
(454)
171/2"
(446)
297/8"
(759)
31/4"
(83)
211/2" (546)
BEHIND FRAME
CONTEMPORARY
297/8"
(759)
177/8"
(454)
21/2"
(64)
7/8"
(22)
171/2"
(446)
211/2" (546)
BEHIND FRAME
213/16"
(538)
OPEN OVEN DOOR
143/16"
(360)
213/16"
(538)
OPEN OVEN DOOR
143/16"
(360)
32 | Wolf Customer Care 800.222.7820
Convection Steam Ovens
Planning Information
The convection steam oven can be installed in a standard or flush inset application.
Finish the edges of the opening. They may be visible when the door is open.
For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT Convection Steam Oven
TRIM OVERLAP Top Bottom Sides
24" MODEL 3/16" (5) 0" (0)
11/16" (18)
MIN 100 lb (45 kg)
30" MODEL 3/16" (5) 0" (0)
37/8" (98)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Refer to the illustration below for minimum power cord plug clearance.
Performance may be compromised if the electrical supply is less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
20 amp dedicated circuit
Receptacle
NEMA 6-20R grounding-type
Power Cord
6' (1.8 m)
1" (25)
MINIMUM CORD
CLEARANCE
Power cord clearance
wolfappliance.com|33
Convection Steam Ovens
Convection Steam Oven
STANDARD INSTALLATION
23" (584)
OPENING DEPTH
TOP VIEW
17 11/16"
(449) OPENING HEIGHT
E
W
OPENING WIDTH
SIDE VIEW NOTE: 24" (610) and 30" (762) models require the same opening dimensions.
FRONT VIEW
OPENING WIDTH 24" Model 30" Model
W 221/8" (562) 221/8" (562)
34 | Wolf Customer Care 800.222.7820
Convection Steam Ovens
Convection Steam Oven
FLUSH INSET INSTALLATION
7/8" (22)
24" (610)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
181/8"
(460)
FLUSH INSET
HEIGHT**
E A
5/16" (8) 1/8" (3)
W
FLUSH INSET WIDTH**
SIDE VIEW
*Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
FRONT VIEW
FLUSH INSET WIDTH 24" Model 30" Model
W 233/4" (603) 301/8" (765)
A 13/16" (21)
4" (102)
wolfappliance.com|35
Speed Ovens
Speed Ovens
The Wolf speed oven has features that make fast meals better meals. Available in 24" and 30" widths, they are designed to match Wolf transitional, professional, and contemporary products. The speed oven can be installed in a standard or flush inset application.
SPEED OVENS TRANSITIONAL
SPO24TE/S/TH PROFESSIONAL
SPO30TM/S/TH
SPO30TE/S/TH
SPO30PM/S/PH CONTEMPORARY
SPO30PE/S/PH
SPO30CM/B/TH
36 | Wolf Customer Care 800.222.7820
Speed Ovens
Speed Ovens
TRANSITIONAL
W
WIDTH
7/8"
(22)
177/8"
(454)
171/2"
(446)
21/2"
(64)
211/2" (546)
BEHIND FRAME
WIDTH 24" Transitional 30" Transitional
W 231/2" (597) 297/8" (759)
213/16"
(538)
OPEN OVEN DOOR
143/16"
(360)
wolfappliance.com|37
Speed Ovens
Speed Ovens
PROFESSIONAL
297/8"
(759)
7/8"
(22)
177/8"
(454)
171/2"
(446)
31/4"
(83)
211/2" (546)
BEHIND FRAME
CONTEMPORARY
7/8"
(22)
177/8"
(454)
171/2"
(446)
297/8"
(759)
21/2"
(64)
211/2" (546)
BEHIND FRAME
213/16"
(538)
OPEN OVEN DOOR
143/16"
(360)
213/16"
(538)
OPEN OVEN DOOR
143/16"
(360)
38 | Wolf Customer Care 800.222.7820
Speed Ovens
Planning Information
The speed oven can be installed in a standard or flush inset application.
Finish the edges of the opening. They may be visible when the door is open.
For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
If the speed oven is installed above or below a Wolf E series oven in a flush inset application, a 1/4" (6) reveal is required.
INSTALLATION REQUIREMENTS
BASE SUPPORT 24" (610) Model 30" (762) Model
TRIM OVERLAP Top Bottom Sides
24" MODEL 3/16" (5) 0" (0)
11/16" (18)
MIN 125 lb (57 kg) 125 lb (57 kg)
30" MODEL 3/16" (5) 0" (0)
37/8" (98)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. The receptacle may also be located in an adjacent cabinet within reach of the power cord. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Refer to the illustration below for minimum power cord plug clearance.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
15 amp dedicated circuit
Receptacle
NEMA 6-20R grounding type
Power Cord
6' (1.8 m)
NEMA PLUG
GROUNDED NEMA RECEPTACLE
1" (25)
MINIMUM CORD
CLEARANCE
NEMA 6-20R receptacle
Power cord clearance
wolfappliance.com|39
Speed Ovens
Speed Oven
STANDARD INSTALLATION
17 11/16"
(449) OPENING HEIGHT
23" (584)
OPENING DEPTH
TOP VIEW
E
W
OPENING WIDTH
SIDE VIEW NOTE: 24" (610) and 30" (762) models require the same opening dimensions.
FRONT VIEW
OPENING WIDTH 24" Model 30" Model
W 221/8" (562) 221/8" (562)
40 | Wolf Customer Care 800.222.7820
Speed Ovens
Speed Oven
FLUSH INSET INSTALLATION
7/8" (22)
24" (610)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
181/8"
(460)
FLUSH INSET
HEIGHT**
E A
5/16" (8) 1/8" (3)
W
FLUSH INSET WIDTH**
SIDE VIEW
*Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
FRONT VIEW
FLUSH INSET WIDTH 24" Model 30" Model
W 233/4" (603) 301/8" (765)
A 13/16" (21)
4" (102)
wolfappliance.com|41
Microwave Ovens
Microwave Ovens
As true cooking instruments, Wolf microwave ovens have features that make fast meals better meals. The drop-down door microwaves feature a door that hinges at the bottom for easier access to foods. Available in 24" and 30" widths, they are designed to match Wolf transitional, professional, and contemporary products. Drawer microwave ovens can be conveniently located undercounter, in a corner, or below an oven. Wolf also offers both a roomy, powerful standard microwave and a convection model that can microwave, broil, and cook in three convection modes. Trim kits to match Wolf ovens are available through an authorized Wolf dealer. Microwave ovens can be installed in a standard or flush inset application.
DROP-DOWN DOOR MICROWAVES TRANSITIONAL
MDD24TE/S/TH PROFESSIONAL
MDD30TM/S/TH
MDD30TE/S/TH
MDD30PM/S/PH CONTEMPORARY
MDD30PE/S/PH
MDD30CM/B/TH
DRAWER MICROWAVE TRANSITIONAL
MD24TE/S PROFESSIONAL
MD30TE/S
MD30PE/S CONVECTION MICROWAVE
MC24 (M/E TRIM)
MC24 (L TRIM)
STANDARD MICROWAVE
42 | Wolf Customer Care 800.222.7820
MS24 (M/E TRIM)
MS24 (L TRIM)
Microwave Ovens
Drop-Down Door Microwave Ovens
TRANSITIONAL
7/8"
(22)
177/8"
(454)
171/2"
(446)
W
WIDTH
21/2"
(64)
20" (508)
BEHIND FRAME
WIDTH 24" Transitional 30" Transitional PROFESSIONAL
297/8"
(759)
W 231/2" (597) 297/8" (759)
7/8"
(22)
177/8"
(454)
171/2"
(446)
31/4"
(83)
20" (508)
BEHIND FRAME
CONTEMPORARY
7/8"
(22)
177/8"
(454)
171/2"
(446)
297/8"
(759)
21/2"
(64)
20" (508)
BEHIND FRAME
213/16"
(538)
OPEN OVEN DOOR
143/16"
(360)
213/16"
(538)
OPEN OVEN DOOR
143/16"
(360)
213/16"
(538)
OPEN OVEN DOOR
143/16"
(360)
wolfappliance.com|43
Microwave Ovens
Drawer Microwave Ovens
TRANSITIONAL / PROFESSIONAL
11/4"
(32)
151/8"
(384)
13/4" POWER CORD
(45) CHANNEL
145/8"
(372)
215/8" (549)
45/8"
(118)
29 7/8" (759)
217/8" (556)
BEHIND FRAME
OPEN DRAWER
WIDTH 24" Model 30" Model
W 237/8" (606) 297/8" (759)
161/2"
(419)
44 | Wolf Customer Care 800.222.7820
Microwave Ovens
14 7/8"
(378) FREESTANDING
Convection Microwave Oven
M/E SERIES TRIM
24243/"4("6(1602)9)
FREESTANDINGG
11" 3(2/85") OR 11(/345")(32)*
119871//84""
((540654)) WWITITHH TTRRIMIM
113437//88""
((334708)) FFRREEEE-SSTTAANNDDIINNGG
TTRRIIMM WWIIDDTTHH *11/4" (32) for contemporary E series trim only.
11785"/8(4"5(74)48)
BBEEHHININDDTTRRIMIM
L SERIES TRIM
24 3/4" (629)
FREESTANDING
13/8"
(35)
19 7/8"
(505) WITH TRIM
14 7/8"
(378) FREESTANDING
TRIM WIDTH
175/8" (448)
BEHIND TRIM
TRIM WIDTH 27" Trim 30" Trim 36" Trim
M SERIES NA
297/8" (759) NA
E SERIES 267/8" (683) 297/8" (759)
NA
L SERIES NA
297/8" (759) 355/8" (905)
Standard Microwave Oven
M/E SERIES TRIM
24" (610)
FREESTANDING
1" (25) OR 11/4" (32)*
181/4"
(464) WITH TRIM
133/8"
(340) FREESTANDING
TRIM WIDTH *11/4" (32) for contemporary E series trim only.
18" (457)
BEHIND TRIM
L SERIES TRIM
24243/"4("6(1602)9)
FREESTANDINGG
119871//84""
((540654)) WWITITHH TTRRIMIM
11" 3(2/85") OR 11(/345")(32)*
113437//88""
((334708)) FFRREEEE-SSTTAANNDDIINNGG
TTRRIIMM WWIIDDTTHH
11785"/8(4"5(74)48)
BBEEHHININDDTTRRIMIM
*11/4" (32) for contemporary E series trim only.
TRIM WIDTH 27" Trim 30" Trim
M SERIES NA
297/8" (759)
E SERIES 267/8" (683) 297/8" (759)
L SERIES NA
297/8" (759)
*11/4" (32)
wolfappliance.com|45
Microwave Ovens
Planning Information
DROP-DOWN DOOR MICROWAVE
The drop-down door microwave oven can be installed in a standard or flush inset application.
Finish the edges of the opening. They may be visible when the door is open.
For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT Drop-Down Door Microwave
TRIM OVERLAP Top Bottom Sides
24" MODEL 3/16" (5) 0" (0)
11/16" (18)
MIN 125 lb (57 kg)
30" MODEL 3/16" (5) 0" (0)
37/8" (98)
DRAWER MICROWAVE
The drawer microwave oven can be installed in a standard or flush inset application. The location of the electrical supply within the oven opening may require additional cabinet depth.
Finish the edges of the opening. They may be visible when the drawer is open.
For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is required on the top and sides and 11/16" (18) on the bottom. To ensure consistent reveals, each corner of the opening must be exactly 90°. A sales accessory is required to direct air away from the unit. Accessories are available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
INSTALLATION REQUIREMENTS
BASE SUPPORT 24" Drawer Microwave 30" Drawer Microwave
TRIM OVERLAP Top Bottom Sides
24" MODEL 5/16" (8) 1/16" (2) 7/8" (22)
MIN 125 lb (57 kg) 125 lb (57 kg)
30" MODEL 5/16" (8) 1/16" (2)
37/8" (98)
46 | Wolf Customer Care 800.222.7820
Microwave Ovens
Planning Information
CONVECTION / STANDARD MICROWAVES
Convection and standard microwave ovens can be installed in a standard or flush inset application using accessory trim to match Wolf ovens. Trim kits are available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
Convection and standard microwave ovens can also be used freestanding. For freestanding applications, a minimum 2" (51) space is required at the top, rear, and sides of the microwave oven for air circulation.
INSTALLATION REQUIREMENTS
BASE SUPPORT Convection Microwave Standard Microwave
27" E SERIES TRIM OVERLAP Top Bottom Sides
30" M/E/L TRIM OVERLAP Top Bottom Sides
36" L SERIES TRIM OVERLAP Top Bottom Sides
CONV 1/4" (6) 3/4" (19) 13/16" (21)
CONV 1/4" (6) 3/4" (19) 13/16" (30)
CONV 3/16" (5) 13/16" (21) 11/4" (32)
MIN 125 lb (57 kg) 125 lb (57 kg)
STAN 9/16" (14) 11/16" (17) 13/16" (21)
STAN 9/16" (14) 11/16" (17) 13/16" (30)
STAN NA NA NA
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. The receptacle may also be located in an adjacent cabinet within reach of the power cord. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Refer to the illustration below for minimum power cord plug clearance.
ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle Power Cord
grounded, 120 VAC, 60 Hz 15 amp dedicated circuit 3-prong grounding-type 4' (1.2 m)
3"
(76)
MINIMUM CORD CLEARANCE
Power cord clearance
wolfappliance.com|47
Microwave Ovens
Drop-Down Door Microwave Oven
STANDARD INSTALLATION
219/16"
(548) OPENING
DEPTH
TOP VIEW
17 11/16"
(449) OPENING HEIGHT
E
W
OPENING WIDTH
SIDE VIEW NOTE: 24" (610) and 30" (762) models require the same opening dimensions.
FRONT VIEW
OPENING WIDTH 24" Model 30" Model
W 221/8" (562) 221/8" (562)
48 | Wolf Customer Care 800.222.7820
Microwave Ovens
Drop-Down Door Microwave Oven
FLUSH INSET INSTALLATION
7/8" (22)
23" (584)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
181/8"
(460)
FLUSH INSET
HEIGHT**
E A
5/16" (8) 1/8" (3)
W
FLUSH INSET WIDTH**
SIDE VIEW
*Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
FRONT VIEW
FLUSH INSET WIDTH 24" Model 30" Model
W 233/4" (603) 301/8" (765)
A 13/16" (21)
4" (102)
wolfappliance.com|49
Microwave Ovens
Drawer Microwave Oven
STANDARD INSTALLATION
ANTI-TIP BLOCK
143/4" (375)
OPENING HEIGHT
22" (559)
OPENING DEPTH
TOP VIEW
E
W
OPENING WIDTH
SIDE VIEW NOTE: All drawer microwave ovens require the same opening dimensions.
FRONT VIEW
OPENING WIDTH 24" Model 30" Model
W 22 1/8" (562) 22 1/8" (562)
50 | Wolf Customer Care 800.222.7820
Microwave Ovens
Drawer Microwave Oven
FLUSH INSET INSTALLATION
ANTI-TIP BLOCK
1515/16" (405)
FLUSH INSET HEIGHT**
11/4" (32)
231/4" (591)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
E A
7/16" (11) 3/4" (19)
W
FLUSH INSET WIDTH**
SIDE VIEW
*Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
FRONT VIEW
FLUSH INSET WIDTH 24" Model 30" Model
W 24 1/8" (613) 30 1/8" (765)
A 1" (25) 4" (102)
wolfappliance.com|51
Microwave Ovens
Convection Microwave Oven
STANDARD INSTALLATION WITH TRIM
201/8" (511)
OPENING DEPTH
TOP VIEW
187/8" (479)
OPENING HEIGHT
E
W
OPENING WIDTH
SIDE VIEW
FRONT VIEW
OPENING WIDTH 27" Trim 30" Trim 36" Trim
W 251/4" (641) 271/2" (699) 333/8" (854)
52 | Wolf Customer Care 800.222.7820
Microwave Ovens
Convection Microwave Oven
FLUSH INSET INSTALLATION WITH TRIM
1" (25)
OR
11/4" (32)**
231/4" (591)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
201/8" (511)
FLUSH INSET HEIGHT***
E A
3/8" (10) 7/8" (22)
W
FLUSH INSET WIDTH***
SIDE VIEW
*Will be visible and should be finished to match cabinetry. **11/4" (32) for contemporary E series trim only. ***Dimension provides minimum reveals.
FRONT VIEW
FLUSH INSET WIDTH 27" Trim 30" Trim
W 271/8" (689) 301/8" (765)
A 15/16" (24) 13/16" (30)
wolfappliance.com|53
Microwave Ovens
Standard Microwave Oven
STANDARD INSTALLATION WITH TRIM
20" (508)
OPENING DEPTH
TOP VIEW
17" (432)
OPENING HEIGHT
E
W
OPENING WIDTH
SIDE VIEW
OPENING WIDTH 27" Trim 30" Trim
FRONT VIEW
W 251/4" (641) 271/2" (699)
54 | Wolf Customer Care 800.222.7820
Microwave Ovens
Standard Microwave Oven
FLUSH INSET INSTALLATION WITH TRIM
1" (25)
OR
11/4" (32)**
231/4" (591)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
181/2" (470)
FLUSH INSET HEIGHT***
E A
11/16" (17) 13/16" (21)
W
FLUSH INSET WIDTH***
SIDE VIEW
*Will be visible and should be finished to match cabinetry. **11/4" (32) for contemporary E series trim only. ***Dimension provides minimum reveals.
FRONT VIEW
FLUSH INSET WIDTH 27" Trim 30" Trim
W 271/8" (689) 301/8" (765)
A 15/16" (24) 13/16" (30)
wolfappliance.com|55
Warming Drawers
Warming Drawers
Wolf warming drawers are designed to take care of prepared foods until it's time to serve them. You can adjust the temperature, keeping moist foods moist, and crisp foods crisp. Warming drawers are ideal for proofing dough. They can also be used to warm robes and towels. Drawer fronts are available to match the look of Wolf ovens, sealed burner rangetops, and outdoor grills. The integrated drawer front allows for a custom panel and handle. Model WWD30O, approved for outdoor installations, is ideal for any outdoor kitchen.
WARMING DRAWER FRONTS M/E SERIES
TRANSITIONAL L SERIES
PROFESSIONAL
CONTEMPORARY
TRANSITIONAL INTEGRATED
CUSTOM PANEL
56 | Wolf Customer Care 800.222.7820
Warming Drawers
Warming Drawers
DRAWER FRONT OPTIONS
Wolf warming drawer fronts allow for many design options, but the warming drawer itself will be the same for all applications. A panel mounting kit is required when installing a custom panel. The panel mounting kit is available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
The 2" (51) thick drawer front, in 30" and 36" widths, is designed to be installed below a sealed burner rangetop or outdoor gas grill, so the panel aligns properly with the front of the rangetop or grill. Dimensions for the warming drawer remain the same, even though the drawer front may be wider to match a Wolf 36" oven, sealed burner rangetop, or outdoor grill.
DIMENSIONS
W
WIDTH
281/4" (718)
OPEN DRAWER
A
10 3/8"
(264)
B
22 3/4" (578)
9"
(229)
211/2"
(546)
STAINLESS STEEL DRAWER FRONT
WIDTH 30" Drawer Front 36" Drawer Front
M SERIES Transitional/Professional Contemporary Stainless Contemporary Black
E SERIES Transitional/Professional Professional (2" thick) Contemporary
L SERIES Transitional
A 7/8" (22) 7/8" (22) 1" (25)
A 11/8" (29) 21/8" (54) 11/4" (32)
A 7/8" (22)
W 297/8" (759) 357/8" (911)
B 31/4" (83) 31/4" (83) 33/8" (86)
B 31/2" (89) 41/2" (114) 35/8" (92)
B 31/2" (89)
INTEGRATED DRAWER FRONT
CUSTOM PANEL Dimensions (typical) Min Thickness
W 297/8" (759)
H 103/8" (264)
D 3/4" (19) 5/8" (16)
wolfappliance.com|57
Warming Drawers
Planning Information
The warming drawer must be installed with a Wolf drawer front, available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Specific installation instructions are included with the drawer front.
The warming drawer can be installed in a standard or flush inset application (excludes L series drawer front).
For a standard installation, the drawer collar and front panel sit proud of the cabinet face frame. A recessed installation requires the cabinetry be recessed by 3/16" (5)
so the collar is flush with the cabinet face frame but the drawer
front will sit proud. A flush inset installation (excludes L series) requires the drawer collar and front panel be recessed to be flush with surrounding cabinetry. Refer to illustrations on the following pages for minimum cabinet dimensions for your specific installation.
Finish the edges of the opening. They may be visible when the drawer is open.
For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
Model WWD30O is CSA approved for outdoor installations.
INSTALLATION REQUIREMENTS Min Base Support Trim Overlap (top, bottom, sides)
200 lb (90 kg) 5/8" (16)
58 | Wolf Customer Care 800.222.7820
Warming Drawers
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and within the shaded area shown in the illustrations on the following pages. For ease of installation, the electrical supply for the warming drawer can be placed in an adjacent cabinet within reach of the power cord.
IMPORTANT NOTE: When installed outdoors, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock.
ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle Power Cord
grounded, 120 VAC, 60 Hz 15 amp dedicated circuit 3-prong grounding-type 3' (.9 m)
wolfappliance.com|59
Warming Drawers
Warming Drawer
STANDARD INSTALLATION
ANTI-TIP BLOCK
91/8" (232)
OPENING HEIGHT
23" (584)
OPENING DEPTH
TOP VIEW
E 28 5/8" (727)
OPENING WIDTH
SIDE VIEW
FRONT VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
60 | Wolf Customer Care 800.222.7820
Warming Drawers
Warming Drawer
FLUSH INSET INSTALLATION
A
DRAWER FRONT DEPTH
24" (610)
FLUSH INSET DEPTH***
TOP VIEW
FINISHED CLEATS*
ANTI-TIP BLOCK
105/8"
(270) FLUSH INSET
HEIGHT**
3/4" (19)
3/4" (19)
E
3/4" (19)
E
301/8" (765)
FLUSH INSET WIDTH**
SIDE VIEW
FRONT VIEW
*Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. ***241/8" (613) for E series contemporary drawer front.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
DRAWER FRONT DEPTH (A)
M SERIES
E SERIES
Transitional/Professional
7/8" (22)
11/8" (29)
Professional (2" thick)
NA
21/8" (54)
Contemporary Stainless
7/8" (22)
NA
Contemporary Black
1" (25)
13/8" (35)
Custom front panel depth is dependent on panel thickness. Add 1/4" (6) to the panel thickness to determine the drawer front depth.
wolfappliance.com|61
Induction/Electric Cooktops
Induction/Electric Cooktops
62 | Wolf Customer Care 800.222.7820
Induction Cooktops
Induction Cooktops
Almost instantaneous temperature response. Practically no wasted heat. Induction cooking has been popular among European chefs and homeowners for decades. Now Wolf leads the way in bringing this remarkable technology to North American kitchens. Its secret is magnetism. Electromagnetic elements cause iron and magnetic stainless cookware to heat up instantly and with perfectly distributed heat. Heat generation stops the instant you turn off the element or remove the pan. The cooktop's surface remains cool. Your kitchen stays cooler too.
Transitional models have a brushed stainless steel trim. Contemporary models can be mounted flush with the countertop. The following models have the same stainless steel frame as our module cooktops for paired installations: CI243TF/S, CI304TF/S, and CI365TF/S.
INDUCTION COOKTOPS TRANSITIONAL FRAMED
CI243TF/S
CI304TF/S
TRANSITIONAL
CI304T/S
CI365T/S
CONTEMPORARY
CI365TF/S
CI243C/B
CI304C/B
CI365C/B
wolfappliance.com|63
Induction Cooktops
Induction Cooktops
24" TRANSITIONAL
21"
(533)
235/8" (600)
CONDUIT
7/8" 11/4" (32) (22)
2" (51)
24" CONTEMPORARY
21"
(533)
235/8" (600)
CONDUIT 21/2" (64) 7/8"
11/4" (32) (22)
30" TRANSITIONAL
21"
(533)
30" (762)
CONDUIT
7/8" 11/4" (32) (22)
2" (51)
30" CONTEMPORARY
21"
(533)
30" (762)
CONDUIT 21/2" (64) 7/8"
11/4" (32) (22)
36" TRANSITIONAL
21"
(533)
36" (914)
CONDUIT
7/8" 11/4" (32) (22)
2" (51)
36" CONTEMPORARY
21"
(533)
36" (914)
CONDUIT 21/2" (64) 7/8"
11/4" (32) (22)
64 | Wolf Customer Care 800.222.7820
Electric Cooktops
Electric Cooktops
Wolf electric cooktops use high-frequency pulsation technology for the most exceptional performance and control ever in a Wolf electric cooktop, with blazing hot sears at the high end and steady simmers and melts at the low end--a low-end finesse that is unusual in an electric cooktop. The updated element configuration accommodates a wide variety of cooking vessels and dish preparation.
ELECTRIC COOKTOPS TRANSITIONAL
CE304T/S CONTEMPORARY
CE365T/S
CE304C/B
CE365C/B
wolfappliance.com|65
Electric Cooktops
Electric Cooktops
30" TRANSITIONAL
21"
(533)
30" (762)
CONDUIT 31/2" (89) 7/8"
11/4" (32) (22)
30" CONTEMPORARY
21"
(533)
30" (762)
CONDUIT
7/8" 11/4" (32) (22)
4" (102)
36" TRANSITIONAL
21"
(533)
36" (914)
CONDUIT 31/2" (89) 7/8"
11/4" (32) (22)
36" CONTEMPORARY
21"
(533)
36" (914)
CONDUIT
7/8" 11/4" (32) (22)
4" (102)
66 | Wolf Customer Care 800.222.7820
Induction/Electric Cooktops
Planning Information
A minimum 2" (51) is required from the bottom of the cooktop to combustible materials.
Contemporary induction and electric cooktops can be mounted flush with the top of the countertop, or as a frameless standard installation sitting on top of the countertop surface. If the cooktop is to be mounted flush with the countertop, a recessed area surrounding the cooktop cutout must be provided.
IMPORTANT NOTE: Flush mount installations are intended for granite, solid surface, or stone countertop surfaces only.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required.
ELECTRICAL REQUIREMENTS
INDUCTION Electrical Supply Conduit
grounded 3-wire, 240/208 VAC, 60 Hz flexible 4' (1.2 m)
ELECTRIC Electrical Supply Electrical Supply (208 V) Conduit
grounded 3-wire, 240 VAC, 60 Hz grounded 3-wire, 208 VAC, 60 Hz
flexible 4' (1.2 m)
SERVICE 24" Induction 30" Induction/Electric 36" Induction/Electric
30 amp dedicated circuit 40 amp dedicated circuit 50 amp dedicated circuit
wolfappliance.com|67
Induction/Electric Cooktops
24" / 30" / 36" Cooktop
STANDARD INSTALLATION
W
WIDTH
21/2" (64)
191/2"
(495)
COUNTERTOP CUTOUT
21/2" (64)
13"
(330)
18"
(457)
2"
(51)
36" (914) min
FLOOR TO COUNTERTOP
30"
(762)
41/2" (114)
31/2" (89)
E
10" (254)
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Electrical supply location only applies to installations with built-in oven.
CUTOUT WIDTH 24" Induction 30" Induction/Electric 36" Induction/Electric
W 221/8" (562)
29" (737) 35" (889)
68 | Wolf Customer Care 800.222.7820
Induction/Electric Cooktops
24" / 30" / 36" Cooktop
FLUSH INSTALLATION
COUNTERTOP PROFILE
5/16" (8)
211/8"
(537) RECESS
19/16" (40) min
W
CUTOUT WIDTH
A
RECESS
COUNTERTOP CUTOUT
21/2" (64)
191/2"
(495)
21/2" (64)
13"
(330)
18"
(457)
2"
(51)
36" (914) min
FLOOR TO COUNTERTOP
30"
(762)
41/2" (114)
31/2" (89)
E
10" (254)
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Electrical supply location only applies to installations with built-in oven. Outside corner radius 7/16" (11).
CUTOUT WIDTH 24" Induction 30" Induction/Electric 36" Induction/Electric
W 221/8" (562)
29" (737) 35" (889)
A 233/4" (603) 301/8" (765) 361/8" (918)
wolfappliance.com|69
Gas Cooktops
Gas Cooktops
Like their oven counterparts, Wolf gas cooktops feature three unique looks--transitional, professional, and contemporary. Performance enhancements make delicious results even more of a certainty than ever. Multiple sizes, choice of knob colors, and distinctly different grates. For a striking, low-profile look, the contemporary gas cooktop fits flush to the countertop with frontmounted controls that integrate directly into cabinetry below.
Model CG243TF/S has the same stainless steel frame as our module cooktops for paired installations.
GAS COOKTOPS TRANSITIONAL FRAMED
CG243TF/S TRANSITIONAL
CG304T/S PROFESSIONAL
CG365T/S
CG304P/S CONTEMPORARY
CG365P/S
CG365C/S
70 | Wolf Customer Care 800.222.7820
Gas Cooktops
Gas Cooktops
24" TRANSITIONAL
21"
(533)
235/8" (600)
4" (102) 3/8"
(10)
30" PROFESSIONAL
30" TRANSITIONAL
21"
(533)
30" (762)
4" (102) 7/8"
(22)
36" PROFESSIONAL
36" TRANSITIONAL
21"
(533)
36" (914)
4" (102) 7/8"
(22)
21"
(533)
30" (762)
4" (102) 7/8"
(22)
36" CONTEMPORARY
21"
(533)
36" (914)
4" (102) 7/8"
(22)
2015/16"
(532)
3515/16" (913)
63/4" (171) 7/8"
(22)
wolfappliance.com|71
Gas Cooktops
Planning Information
A minimum 2" (51) is required from the bottom of the cooktop to combustible materials. If the cooktop is installed above an oven, a minimum of 1/4" (6) is required between the units.
The contemporary gas cooktop can be mounted flush with the top of the countertop, or as a standard installation sitting on top of the countertop surface. If the cooktop is to be mounted flush with the countertop, a recessed area surrounding the cooktop cutout must be provided. The countertop must be able to withstand temperatures up to 300°F (149°C).
Control knobs for the contemporary gas cooktop are designed to be mounted on the front face of cabinetry below the unit. Mounting holes must be drilled through the cabinet face. Refer to the illustrations on pages 7475 for the hole location.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle Power Cord
grounded, 120 VAC, 60 Hz 15 amp dedicated circuit 3-prong grounding-type 6' (1.8 m)
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended.
Wolf natural gas cooktops will function up to 10,250' (3124 m) in altitude without adjustment and LP gas cooktops will function up to 8,600' (2621 m). If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.
GAS REQUIREMENTS
Gas Supply
Gas Inlet
NATURAL GAS Supply Pressure Min Line Pressure Max Regulator Pressure
LP GAS Supply Pressure Min Line Pressure Max Regulator Pressure
3/4" ID line
1/2" NPT male
WC 5" (12.5 mb) 7" (17.5 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
WC 10" (25 mb) 11" (27.4 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
72 | Wolf Customer Care 800.222.7820
Gas Cooktops
24" / 30" / 36" Transitional / Professional Gas Cooktop
STANDARD INSTALLATION
W
WIDTH
21/2" (64)
191/2"
(495)
COUNTERTOP CUTOUT
21/2" (64)
13"
(330)
18"
(457)
9"
(229)
30"
(762)
4" (102) 31/2" (89) E G
10" (254)
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Electrical and gas supply location only applies to installations with built-in oven.
CUTOUT WIDTH 24" Transitional 30" Transitional/Professional 36" Transitional/Professional
W 23" (584) 29" (737) 35" (889)
wolfappliance.com|73
Gas Cooktops
36" Contemporary Gas Cooktop
STANDARD INSTALLATION
35" (889)
CUTOUT WIDTH
21/2" (64)
20"
(508)
COUNTERTOP CUTOUT
13"
(330)
2" (51) MIN 5" (127) MAX
18"
(457)
9"
(229)
30"
(762)
5"
(127)
10"
(254) C L
43"7(/180"2(9) 8) MIN 51/8" (130) MAX
C L
11/4" (32)
DIAMETER
E G
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Maximum facade thickness 1" (25). 1" (25) thickness extends 17" (432) left and right and 2" (51) above and below centerlines.
74 | Wolf Customer Care 800.222.7820
Gas Cooktops
36" Contemporary Gas Cooktop
FLUSH INSTALLATION
COUNTERTOP PROFILE
5/64" (2)
21"
(533) MIN RECESS
35" (889)
CUTOUT WIDTH
36" (914) MIN
RECESS
COUNTERTOP CUTOUT
21/2" (64)
20"
(508)
13"
(330)
2" (51) MIN 5" (127) MAX
18"
(457)
9"
(229)
30"
(762)
5"
(127)
10"
(254) C L
43"7(/180"2(9) 8) MIN 51/8" (130) MAX
C L
11/4" (32)
DIAMETER
E G
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Maximum facade thickness 1" (25). 1" (25) thickness extends 17" (432) left and right and 2" (51) above and below centerlines. Outside corner radius 3/8" (10).
wolfappliance.com|75
Module Cooktops
Module Cooktops
Wolf modules have been redesigned to match the updated lines of Sub-Zero and Wolf. Controls, grates, and trim allow them to integrate perfectly with their larger counterparts and deliver equal performance. Combine modules à la carte-style to create a custom cooktop, or add specialty functions alongside an existing cooktop.
Full-size cooktops including CI243TF/S, CG243TF/S, CI304TF/S, and CI365TF/S feature the same brushed stainless frame, making them ideal for pairing with modules.
MODULE COOKTOPS
CI152TF/S INDUCTION
CE152TF/S ELECTRIC
SM15TF/S STEAMER
FM15TF/S FRYER
GM15TF/S GRILL
TM15TF/S TEPPANYAKI
CG152TF/S GAS
MM15TF/S MULTIFUNCTION
76 | Wolf Customer Care 800.222.7820
Module Cooktops
Module Cooktops
INDUCTION
ELECTRIC
21"
(533)
21"
(533)
15"
(381)
CONDUIT
7/8" 11/4" (22)
(32)
2" (51)
15"
(381)
CONDUIT 31/2" (89) 7/8"
11/4" (22)
(32)
GRILL
21"
(533)
15"
(381)
7/8" 11/4" (22)
(32)
5"
(127)
TEPPANYAKI
21"
(533)
15"
(381)
4" (102) 7/8"
(22)
STEAMER
21"
(533)
15"
(381)
7/8"
4"
(22)
(102)
DRAIN OUTLET
83/4"
(222)
GAS
21"
(533)
15"
(381)
4" (102) 7/8"
(22)
FRYER
21"
(533)
15"
(381)
7/8"
4"
(22)
(102)
DRAIN OUTLET
83/4"
(222)
MULTIFUNCTION
21"
(533)
15"
(381)
5" (127) 7/8"
(22)
wolfappliance.com|77
Module Cooktops
Planning Information
IMPORTANT NOTE: Wolf does not recommend the use of downdraft ventilation with the steamer, fryer, or grill modules.
A minimum 2" (51) is required from the bottom of the module to combustible materials. For the teppanyaki module, a minimum 7/8" (22) is required from the bottom of the unit to any material.
Refer to the illustrations on the following pages for installation of modules.
MULTIPLE COOKTOPS
When multiple cooktops or modules are installed side by side, refer to the chart and illustration below for typical configurations. The cutout dimensions provided will accommodate the use of an optional filler strip if desired.
For specific multiple cooktop and module configuration options or the installation of more than six modules, contact Wolf Customer Care at 800-222-7820.
COUNTERTOP CUTOUT
W
(2) 15" Modules*
29" (737)
(3) 15" Modules*
44" (1118)
(4) 15" Modules*
591/4" (1505)
(5) 15" Modules*
741/4" (1886)
(6) 15" Modules*
891/4" (2267)
24" Cooktop**/15" Module*
375/8" (956)
30" Cooktop/15" Module*
44" (1118)
30" Cooktop/(2) 15" Modules*
59" (1473)
36" Cooktop/15" Module*
50" (1270)
*Dimensions apply to CI152TF/S, CE152TF/S, CG152TF/S, SM15TF/S, FM15TF/S, GM15TF/S, TM15TF/S and MM15TF/S.
**235/8" actual product width.
W
CUTOUT WIDTH
21/2"
(64) min
21/2"
(64) min
191/2"
(495)
CUTOUT
DEPTH
FRONT OF COUNTERTOP
Countertop cutout
78 | Wolf Customer Care 800.222.7820
Module Cooktops
Planning Information
ELECTRICAL Installation must comply with all applicable electrical codes. Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. When multiple cooktops or modules are installed side by side, each must have its own separate electrical supply.
ELECTRICAL REQUIREMENTS
ELECTRIC MODULES
Electrical Supply
grounded 3-wire, 240/208 VAC, 50/60 Hz
Steamer, Fryer, Grill, Teppanyaki
15 amp dedicated circuit
Induction, Electric
20 amp dedicated circuit
Conduit
flexible 4' (1.2 m)
GAS MODULES Electrical Supply Service Receptacle Power Cord
grounded, 120 VAC, 50/60 Hz 15 amp dedicated circuit 3-prong grounding-type 6' (1.8 m)
DRAIN OUTLET
Steamer and fryer modules require a method for draining hot water and oil. For the steamer module, options include connecting a drain hose from the 5/8" (16) outlet tied into an existing drain, a separate drain with freefall, or placing a heat-resistant receptacle under the drain outlet. For the fryer module, the drain outlet must be accessible to drain oil into a heat-resistant receptacle.
wolfappliance.com|79
Module Cooktops
Planning Information
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended.
When multiple gas cooktops or modules are installed side by side, they can receive their gas supply from a common line. However, each unit must have its own regulator installed between the mainline and the cooktop or module.
Wolf natural gas cooktops will function up to 10,250' (3124 m) in altitude without adjustment and LP gas cooktops will function up to 8,600' (2621 m). If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.
GAS REQUIREMENTS
Gas Supply
Gas Inlet
NATURAL GAS Supply Pressure Min Line Pressure Max Regulator Pressure
LP GAS Supply Pressure Min Line Pressure Max Regulator Pressure
3/4" ID line
1/2" NPT male
WC 5" (12.5 mb) 7" (17.5 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
WC 10" (25 mb) 11" (27.4 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
GAS REQUIREMENTS
Gas Supply
Gas Inlet
NATURAL GAS Supply Pressure Min Line Pressure Max Regulator Pressure
LP GAS Supply Pressure Min Line Pressure Max Regulator Pressure
3/4" ID line
1/2" NPT male
WC 5" (12.5 mb) 7" (17.5 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
WC 10" (25 mb) 11" (27.4 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
80 | Wolf Customer Care 800.222.7820
Module Cooktops
Induction / Electric Module
STANDARD INSTALLATION
21/2" (64)
14"
(356)
191/2"
(495)
21/2" (64)
COUNTERTOP CUTOUT
13"
(330)
18"
(457)
2"
(51)
36" (914) min
FLOOR TO COUNTERTOP
30"
(762)
E
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
wolfappliance.com|81
Module Cooktops
Steamer Module
STANDARD INSTALLATION
21/2" (64) min
14"
(356)
191/2"
(495)
21/2" (64) min
COUNTERTOP CUTOUT
13"
(330)
77/8"
(200)
18"
(457)
30"
(762)
7"
(178)
123/8"
(314)
6"
(152)
DRAIN OUTLET
E
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
WARNING
The steamer module must be installed at least 15" (381) from a fryer module.
82 | Wolf Customer Care 800.222.7820
Module Cooktops
Fryer Module
STANDARD INSTALLATION
21/2" (64) min
14"
(356)
191/2"
(495)
21/2" (64) min
COUNTERTOP CUTOUT
13"
(330)
77/8"
(200)
18"
(457)
30"
(762)
7"
(178)
123/8"
(314)
6"
(152)
DRAIN OUTLET
E
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
WARNING
The fryer module must be installed at least 15" (381) from any open-flame cooking device or a steamer module.
wolfappliance.com|83
Module Cooktops
Grill / Teppanyaki Module
STANDARD INSTALLATION
21/2" (64) min
14"
(356)
191/2"
(495)
21/2" (64) min
COUNTERTOP CUTOUT
13"
(330)
18"
(457)
7"
(178)
30"
(762)
E
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
84 | Wolf Customer Care 800.222.7820
Module Cooktops
Gas / Multifunction Module
STANDARD INSTALLATION
14"
(356)
21/2" (64)
191/2"
(495)
21/2" (64)
COUNTERTOP CUTOUT
13"
(330)
18"
(457)
7"
(178)
30"
(762)
EG
SIDE VIEW
FRONT VIEW
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
wolfappliance.com|85
Coffee System
Coffee System
Make professional-quality coffee, espresso, cappuccino, latte, and more. The Wolf coffee system automatically steams and foams the milk perfectly. The water temperature and brew strength are adjustable. It uses either whole-bean or ground coffee. The design pairs beautifully, either side-by-side or in a tower application, with other Wolf products such as the convection steam oven. The coffee system can be installed in a standard or flush inset application. All 30" trim options are based on model EC24/B.
COFFEE SYSTEM 24" MODELS
EC24/B TRANSITIONAL
EC24/S
30" M SERIES TRIM PROFESSIONAL
30" E SERIES TRIM
30" M SERIES TRIM CONTEMPORARY
30" E SERIES TRIM
30" M/E SERIES TRIM
86 | Wolf Customer Care 800.222.7820
Coffee System
Coffee System
DIMENSIONS
7/8"
(22)
177/8"
(454)
W
WIDTH
18" (457)
BEHIND FRAME
UNIT FULL EXTENSION
181/4"
(464)
WIDTH 24" Model 30" Trim
W 231/2" (597) 297/8" (759)
wolfappliance.com|87
Coffee System
Planning Information
The coffee system can be installed in a standard or flush inset application. Trim kits are available for vertical, single and horizontal configurations. All 30" trim options are based on model EC24/B. There are no trim options for model EC24/S.
The sides of the cabinetry opening must be adequate to support installation of the mounting slides. Refer to the illustration below.
Finish the edges of the opening. They may be visible when the unit is slid forward.
For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT Coffee System
TRIM OVERLAP Top Bottom Sides
24" MODEL 3/16" (5) 0" (0)
11/16" (18)
MIN 100 lb (45 kg)
30" TRIM 3/16" (5) 0" (0)
37/8" (98)
COMBINATION INSTALLATIONS
IMPORTANT NOTE: If a product is installed next to the coffee system, a horizontal kit must be specified. For all other configurations, a vertical kit must be specified.
To install a coffee system above a cup warming drawer, one opening for both units must be specified. To achieve the minimum reveal between the units, place the coffee system support rails on top of the cup warming drawer, then secure the rails to the sides of the cabinet. Any material between the units will increase the horizontal reveal between the two products.
14"
(356)
3/4" (19)
TYPICAL
10"
(254)
Side support
88 | Wolf Customer Care 800.222.7820
Coffee System
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle Power Cord
grounded, 120 VAC, 60 Hz 15 amp dedicated circuit 3-prong grounding-type 6' (1.8 m)
wolfappliance.com|89
Coffee System
Coffee System
STANDARD INSTALLATION
SLIDE SUPPORT
219/16"
(548) OPENING
DEPTH
TOP VIEW
SLIDE SUPPORT
1711/16" (449)
OPENING HEIGHT
E
W
OPENING WIDTH
SIDE VIEW
FRONT VIEW
NOTE: 24" (610) model and model with 30" (762) trim require the same opening dimensions.
OPENING WIDTH 24" Model 30" Trim
W 221/8" (562) 221/8" (562)
90 | Wolf Customer Care 800.222.7820
Coffee System
Coffee System
FLUSH INSET INSTALLATION
SLIDE SUPPORT
7/8" (22)
23" (584)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
SLIDE SUPPORT
181/8" (460)
FLUSH INSET HEIGHT**
5/16" (8)
A
E
1/8" (3)
W
FLUSH INSET WIDTH**
SIDE VIEW
*Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
FRONT VIEW
FLUSH INSET WIDTH 24" Model 30" Trim
W 233/4" (603) 301/8" (765)
A 13/16" (21)
4" (102)
wolfappliance.com|91
Cup Warming Drawer
Cup Warming Drawer
The Wolf cup warming drawer preheats cups so hot beverages stay hot longer. The temperature is adjustable. Two model options match the look of Wolf stainless and black coffee systems. The cup warming drawer can be installed in a standard or flush inset application.
CUP WARMING DRAWERS
CW24/S STAINLESS
CW24/B BLACK
92 | Wolf Customer Care 800.222.7820
Cup Warming Drawer
Cup Warming Drawer
DIMENSIONS
231/2" (597)
51/2"
(140)
7/8"
(22)
21" (533)
BEHIND FRAME
DRAWER FULL EXTENSION
19"
(483)
Planning Information
The cup warming drawer can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the drawer is open.
For standard installations, the face trim will overlap stiles and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT Cup Warming Drawer
TRIM OVERLAP Top Bottom Sides
MIN 75 lb (34 kg)
0" (0) 0" (0) 11/16" (18)
COMBINATION INSTALLATION
To install a cup warming drawer below a coffee system, one opening for both units must be specified. To achieve the minimum reveal between the units, place the coffee system support rails on top of the cup warming drawer, then secure the rails to the sides of the cabinet. Any material between the units will increase the horizontal reveal.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle Power Cord
grounded, 120 VAC, 60 Hz 10 amp dedicated circuit 3-prong grounding-type 3' (.9 m)
wolfappliance.com|93
Cup Warming Drawer
Cup Warming Drawer
STANDARD INSTALLATION
221/2"
(572) OPENING
DEPTH
TOP VIEW
ANTI-TIP BLOCK
51/2" (140)
OPENING HEIGHT
E
221/8" (562)
OPENING WIDTH
SIDE VIEW
FRONT VIEW
94 | Wolf Customer Care 800.222.7820
Cup Warming Drawer
Cup Warming Drawer
FLUSH INSET INSTALLATION
7/8" (22)
231/2" (597)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
ANTI-TIP BLOCK
53/4" (146)
FLUSH INSET HEIGHT**
1/8" (3)
13/16" E 1/8" (3)
(21)
233/4" (603)
FLUSH INSET WIDTH**
SIDE VIEW
*Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals.
FRONT VIEW
wolfappliance.com|95
Vacuum Seal Drawer
Vacuum Seal Drawer
The vacuum seal drawer can be installed in a standard or flush inset application. Stainless steel, black glass, and integrated drawer fronts are available in 24" and 30" widths. The integrated drawer front allows for a custom panel.
DRAWER FRONTS
STAINLESS STEEL
BLACK GLASS
INTEGRATED
96 | Wolf Customer Care 800.222.7820
Vacuum Seal Drawer
Dimensions
VACUUM SEAL DRAWER
231/2" (597)
51/2"
(140)
7/8"
(22)
21" (533)
BEHIND FRAME
DRAWER FULL
EXTENSION
17"
(432)
DRAWER FRONT
51/2"
(140)
W
DRAWER FRONT 24" Drawer Front 30" Drawer Front
W 231/2" (597) 297/8" (759)
wolfappliance.com|97
Vacuum Seal Drawer
Planning Information
The vacuum seal drawer can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the drawer is open.
For standard installations, face trim will overlap stiles and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT Vacuum Seal Drawer
TRIM OVERLAP Top Bottom Sides
MIN 75 lb (34 kg)
0" (0) 0" (0) 11/16" (18)
FILLER
A filler is required if installed below a countertop. The lid is designed to remain open at 60°. Refer to the illustration below.
2" (51)
60°
2" (51) FILLER
Filler
98 | Wolf Customer Care 800.222.7820
Vacuum Seal Drawer
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle Power Cord
grounded, 120 VAC, 60 Hz 10 amp dedicated circuit 3-prong grounding-type 3' (.9 m)
wolfappliance.com|99
Vacuum Seal Drawer
Vacuum Seal Drawer
STANDARD INSTALLATION
221/2"
(572) OPENING
DEPTH
TOP VIEW
ANTI-TIP BLOCK
59/16" (141)
OPENING HEIGHT
E
221/8" (562)
OPENING WIDTH
SIDE VIEW
FRONT VIEW
100 | Wolf Customer Care 800.222.7820
Vacuum Seal Drawer
Vacuum Seal Drawer
FLUSH INSET INSTALLATION
7/8" (22)**
231/2" (597)
FLUSH INSET DEPTH
TOP VIEW
FINISHED CLEATS*
ANTI-TIP BLOCK
53/4" (146)
FLUSH INSET HEIGHT***
1/16" (2)
A
E 1/8" (3)
W
FLUSH INSET WIDTH***
SIDE VIEW
*Will be visible and should be finished to match cabinetry. **Cleat depth assumes a stainless steel, black glass, or 3/4" (19) custom panel. ***Dimension provides minimum reveals.
FLUSH INSET WIDTH 24" Opening 30" Opening
W 233/4" (603) 301/8" (765)
A 13/16" (21)
4" (102)
FRONT VIEW
wolfappliance.com|101
Dual Fuel Ranges
Dual Fuel Ranges
Discover a new world of cooking--the best of two worlds, actually--with a Wolf dual fuel range. Topside, gas cooking in all its glory, with the fine control of dual-stacked, sealed burners and options that include the remarkable French top. Below, that marvel of culinary technology, the Wolf convection electric oven. Its two fans and four heating elements let you select from 10 cooking modes so you can choose the one precisely suited to the dish you're preparing. The ovens are self-cleaning. With a variety of range widths to choose from, kitchens large and small become gateways to the exciting new world of dual fuel cooking. All models are constructed of stainless steel and can be ordered in natural or LP gas.
CONFIGURATIONS
30" RANGE
48" RANGE
60" RANGE
DF30450
DF48850
DF60650CG
36" RANGE
DF48650C
DF60650DG
DF36650
DF48650G
DF60650F
DF36450C
DF48450CG
DF36450G
DF48450DG
DF48450F
102 | Wolf Customer Care 800.222.7820
Dual Fuel Ranges
Dual Fuel Ranges
30" RANGE
36" RANGE
291/2" (749) 267/8" (683)
24" (610)
48" RANGE
291/2" (749) 267/8" (683)
24" (610)
361/2"
(927)
351/2"
(902)*
361/2"
(927)
351/2"
(902)*
361/2"
(927)
351/2"
(902)*
297/8" (759)
60" RANGE
357/8" (911) 26" (660) 471/4" (1200)
477/8" (12126)6" (660) 471/4" (1200)
*351/2" (902) MIN TO 38" (965) MAX
*351/2" (902) MIN TO 38" (965) MAX
*
29291/12/"2"(7(4794)9) 26267/78/"8("6(8638)3)
242"4("6(1601)0)
36361/12/"2"
(9(2972)7)
35351/12/"2"
(9(0920)2* )*
59597/78/"8"(1(512512)1)
262"6("6(6606)0) 47471/14/"4("1(210200)0) *3*5351/12/"2("9(0920)2M) MININTOTO383"8("9(6956)5M) MAXAX
SIDE VIEW--ALL RANGES
wolfappliance.com|103
Dual Fuel Ranges
Planning Information
IMPORTANT NOTE: When installing against a combustible surface, a minimum 10" (254) riser is required for a 36" dual fuel range with charbroiler or griddle and all 48" and 60" models. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page.
A Wolf pro ventilation hood is recommended with the dual fuel range. Refer to page 148 for Pro Ventilation.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and within the shaded area shown in the illustration on the following page. A separate circuit servicing only this appliance is required.
If a power supply cord is used, the cord must be designated for use with ranges and rated for 240 V, 30 or 50 amps (refer to the chart below), and must include 3 or 4 conductors. A 4-conductor cord is required for installations where grounding through the neutral is prohibited.
Performance may be compromised if the electrical supply is less than 240 volts.
ELECTRICAL REQUIREMENTS--SINGLE OVEN
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
30 amp dedicated circuit
Total Amps
21
Max Connected Load
5.2 kW
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended.
Wolf natural gas ranges will function up to 10,250' (3124 m) in altitude without adjustment and LP gas ranges will function up to 8,600' (2621 m). If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.
GAS REQUIREMENTS
Gas Supply
Gas Inlet
NATURAL GAS Supply Pressure Min Line Pressure Max Regulator Pressure
LP GAS Supply Pressure Min Line Pressure Max Regulator Pressure
3/4" ID line
1/2" NPT female
WC 5" (12.5 mb) 7" (17.5 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
WC 10" (25 mb) 11" (27.4 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
ELECTRICAL REQUIREMENTS--DOUBLE OVEN
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
50 amp dedicated circuit
Total Amps
42.5
Max Connected Load
10.2 kW
104 | Wolf Customer Care 800.222.7820
Dual Fuel Ranges
Dual Fuel Range
INSTALLATION
13"
(330)
18"
(457)
6"
(152)
30" (762) TO 36" (914)
TO BOTTOM OF
VENTILATION HOOD*
W
OPENING WIDTH
ELECTRICAL AND GAS IN `A' LOCATION
ONLY
2"
(51)
SIDE VIEW
36 7/8" (937)
TO COOKING SURFACE
47/8"
(124)
A
E
G
81/2"
(216)
FRONT VIEW
*Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials, 44" (1118) for charbroiler.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. For island installation, 12" (305) minimum clearance back of range to combustible rear wall above countertop.
OPENING WIDTH 30" Range 36" Range 48" Range 60" Range
W 30" (762) 36" (914) 48" (1219) 60" (1524)
A 101/4" (260) 161/4" (413) 181/4" (464) 181/4" (464)
wolfappliance.com|105
Gas Ranges
Gas Ranges
Wolf gas ranges offer the same function, durability and exhilarating performance our ranges have become famous for. Now add the fine control of dual-stacked, sealed burners for gas cooking with superior results. Choose from a multitude of sizes and features to fit your cooking style. Standard features include an infrared broiler and convection baking. Options include infrared griddle, charbroiler, and the innovative French top. All gas range models are constructed of stainless steel and can be ordered in natural or LP gas.
CONFIGURATIONS
30" RANGE
48" RANGE
60" RANGE
GR304
GR488
GR606DG
36" RANGE
GR486C
GR606F
GR366
GR486G
GR606CG
GR364C
GR484CG
GR364G
GR484DG
106 | Wolf Customer Care 800.222.7820
Gas Ranges
Gas Ranges
30" RANGE
36" RANGE
283/8" (721) 27" (686)
91/4"
(235)
56" (1422)
46" (1168)
41" 4(1084"1)RANGE
283/8" (721) 27" (686)
91/4"
(235)
56" (1422)
46" (1168) 41" (1041)
37"
(940)*
36"
(914)
253/8" (645) 37" 37" 36"
(940)* (940)* (914)
253/8" (645)
37" 37"
(940)*(940)*
36"
(914)
297/8" (759)
60" RANGE
21/2"
(64)
357/8" (911) 43 3/8" (1102)
*37" (940) MIN TO 38" (965) MAX.
21/2"
(64)
477/8" (4123136/)8" (1102)
*37" (940) MIN TO 38" (965) MAX. 283/8" (721)
27" (686)
56" (1422)
91/4"
(235)
46" (1168) 41" (1041)
21/2"
(64)
601/8" (1527)
37"
(940)*
36"
(914)
253/8" (645)
37"
(940)*
21/2"
(64)
43 3/8" (1102)
*37" (940) MIN TO 38" (965) MAX.
SIDE VIEW--ALL RANGES
wolfappliance.com|107
Gas Ranges
Planning Information
When installing against a combustible surface, a minimum 20" (508) riser is required. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page.
A Wolf pro ventilation hood is recommended with the gas range. Refer to page 148 for Pro Ventilation.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and within the shaded area shown in the illustration on the following page. A separate circuit servicing only this appliance is required.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 110/120 VAC, 60 Hz
Service
15 amp dedicated circuit
Receptacle
3-prong grounding-type
Power Cord
6' (1.8 m)
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended.
Wolf natural gas ranges will function up to 8,600' (2621 m) in altitude without adjustment. If the installation exceeds this elevation, contact an authorized Wolf dealer for a high altitude conversion kit. LP models do not require conversion.
GAS REQUIREMENTS
Gas Supply
Gas Inlet
NATURAL GAS Supply Pressure Min Line Pressure Max Regulator Pressure
LP GAS Supply Pressure Min Line Pressure Max Regulator Pressure
3/4" ID line
1/2" NPT female
WC 5" (12.5 mb) 7" (17.5 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
WC 10" (25 mb) 11" (27.4 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
108 | Wolf Customer Care 800.222.7820
Gas Ranges
Gas Range
INSTALLATION
13"
(330)
18"
(457)
6"
(152)
30" (762) TO 36" (914)
TO BOTTOM OF
VENTILATION HOOD*
W
OPENING WIDTH
37" (940)
TO COOKING SURFACE
LOCATION OF GAS AND ELECTRICAL EXTENDS
ON FLOOR
3"
(76)
SIDE VIEW
FRONT VIEW
53/4"
(146)
12"
(305)
E
10" (254)
73/4" (197)
2" (51) G
12"
(305) GAS
5"
(127)
*Without ventilation hood, 42" (1067) minimum clearance countertop to combustible materials, charbroiler and GR488 require non-combustible materials.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. For island installation, 12" (305) minimum clearance back of range to combustible rear wall above countertop.
OPENING WIDTH 30" Range 36" Range 48" Range 60" Range
W 30" (762) 36" (914) 48" (1219) 601/4" (1530)
wolfappliance.com|109
Induction Ranges
Induction Ranges
Experience a new way of cooking with a Wolf induction range. Magnetism allows the ultrafast, energy efficient surface elements to heat up instantly and with perfectly distributed heat. Heat generation stops the instant you turn off the element or remove the pan. The cooktop's surface remains cool. Your kitchen stays cooler too. The electric convection oven with two fans and four heating elements let you select from ten cooking modes and is self-cleaning. Wolf induction ranges are constructed of stainless steel and come in 30" and 36" widths with a tubular handle.
CONFIGURATIONS 30" RANGE
36" RANGE
IR30450
IR36550
110 | Wolf Customer Care 800.222.7820
Induction Ranges
Induction Ranges
30" RANGE
351/2"
(902)*
36" RANG2E81/4" (718)
271/2" (699) 241/4" (616)
351/2"
(902)*
281/4" (718) 271/2" (699) 241/4" (616)
297/8" (759)
236517/48" ((696171)) 471/4" (1200)
*351/2" (902) MIN TO 38" (965) MAX
261/4" (667) 471/4" (1200) *351/2" (902) MIN TO 38" (965) MAX
SIDE VIEW--ALL RANGES
wolfappliance.com|111
Induction Ranges
Planning Information
Follow all minimum clearances to combustible surfaces shown in the illustration on the following page.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and within the shaded area shown in the illustration on the following page. A separate circuit servicing only this appliance is required.
If a power supply cord is used, the cord must be designated for use with ranges and rated for 240 V, 50 amps, and must include 3 or 4 conductors. A 4-conductor cord is required for installations where grounding through the neutral is prohibited.
Performance may be compromised if the electrical supply is less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
50 amp dedicated circuit
112 | Wolf Customer Care 800.222.7820
Induction Ranges
Induction Range
INSTALLATION
13"
(330)
18"
(457)
6"
(152)
30" (762) TO 36" (914)
TO BOTTOM OF
VENTILATION HOOD*
W
OPENING WIDTH
36" (914)
TO COOKING SURFACE
ELECTRICAL IN `A' LOCATION ONLY
2"
(51)
SIDE VIEW
A
47/8"
(124)
E
FRONT VIEW
81/2"
(216)
*Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. For island installation, 12" (305) minimum clearance back of range to combustible rear wall above countertop.
OPENING WIDTH 30" Range 36" Range
W 30" (762) 36" (914)
A 101/4" (260) 161/4" (413)
wolfappliance.com|113
Sealed Burner Rangetops
Sealed Burner Rangetops
Wolf sealed burner rangetops incorporate all the gas cooking features of a Wolf dual fuel range. Customize your rangetop with your preferred combination of burners, infrared griddle, charbroiler, French top, or wok burner. All sealed burner rangetop models are constructed of stainless steel and can be ordered in natural or LP gas.
CONFIGURATIONS 30" RANGETOP 36" RANGETOP
48" RANGETOP
SRT304
SRT366
SRT486C
SRT364C
SRT486G
SRT364G
SRT484CG
SRT362W
SRT484DG
SRT484F
SRT484W
114 | Wolf Customer Care 800.222.7820
Sealed Burner Rangetops
Sealed Burner Rangetops
30" RANGETOP
281/2" (724)
91/4"
(235)
271/2" (699)
171/2" (445) 121/2" (318)
29 7/8" (759)
81/2"
(216)
71/2"
(191)
36" RANGETOP (WOK MODEL SHOWN)
11/2" (38)
241/8" (613)
81/2"
(216)
261/8" (664)
281/2" (724)
91/4"
(235)
271/2" (699)
171/2" (445) 121/2" (318)
35 7/8" (911)
48" RANGETOP
81/2" (216) 71/2"
(191)
241/8" (613)
81/2"
(216)
261/8" (6642)81/2" (724)
91/4"
(235)
271/2" (699)
171/2" (445) 121/2" (318)
477/8" (1216)
81/2"
(216)
71/2"
(191)
241/8" (613) 261/8" (664)
81/2"
(216)
SIDE VIEW--ALL RANGETOPS
wolfappliance.com|115
Sealed Burner Rangetops
Planning Information
The platform to support the sealed burner rangetop must include a cutout for electrical and gas supply connections. Refer to the chart below for minimum base support.
When installing against a combustible surface, a minimum 5" (127) riser is required for model SRT366, and a minimum 10" (254) riser is required for 36" and 48" sealed burner rangetops with a charbroiler or griddle. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page. Models SRT362W and SRT484W cannot be installed against a combustible surface.
A Wolf pro ventilation hood is recommended with the sealed burner rangetop. Refer to page 148 for Pro Ventilation.
A downdraft can be used with models SRT304 and SRT366. An accessory trim kit is necessary for this installation. Contact an authorized Wolf dealer for details.
INSTALLATION REQUIREMENTS
BASE SUPPORT 30" Rangetop 36" Rangetop 48" Rangetop
PLATFORM Thickness
MIN 200 lb (91 kg) 250 lb (113 kg) 300 lb (136 kg)
MIN 3/4" (19)
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown in the illustration on the following page. A separate circuit servicing only this appliance is required.
ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle Power Cord
grounded, 110/120 VAC, 60 Hz 15 amp dedicated circuit 3-prong grounding-type 6' (1.8 m)
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended.
Wolf natural gas rangetops will function up to 10,250' (3124 m) in altitude without adjustment and LP gas rangetops up to 8,600' (2621 m). If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.
GAS REQUIREMENTS
Gas Supply
Gas Inlet
NATURAL GAS Supply Pressure Min Line Pressure Max Regulator Pressure
LP GAS Supply Pressure Min Line Pressure Max Regulator Pressure
3/4" ID line
1/2" NPT female
WC 5" (12.5 mb) 7" (17.5 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
WC 10" (25 mb) 11" (27.4 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
116 | Wolf Customer Care 800.222.7820
Sealed Burner Rangetops
Sealed Burner Rangetop
INSTALLATION
13"
(330)
24" (610) MAX
PLATFORM
71/2" (191)
OPENING HEIGHT
18"
(457)
6"
(152)
30" (762) TO 36" (914)
TO BOTTOM OF
VENTILATION HOOD*
W
OPENING WIDTH
PLATFORM
PLATFORM
4" TOP VIEW
(102) BACK WALL
E G
16" (406)
ELECTRICAL AND GAS
SIDE VIEW
FRONT VIEW
*Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials, 44" (1118) for charbroiler.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Electrical and gas supply located through bottom of platform. For island installation, 12" (305) minimum clearance back of rangetop to combustible rear wall above countertop.
OPENING WIDTH 30" Rangetop 36" Rangetop 48" Rangetop
W 30" (762) 36" (914) 48" (1219)
wolfappliance.com|117
Outdoor Grills/Modules
Outdoor Grills/Modules
Taste what happens when the heritage of professional cooking moves from the kitchen to the patio. Like their indoor counterparts, Wolf outdoor grills are precision instruments. Constructed of heavy-duty stainless steel, the 30", 36", 42", and 54" grills have powerful burners every five inches for even heat distribution. An electric rotisserie with infrared burner produces succulent poultry and roasts. All grill models can be built in and all except the 54" grill, can be used on a cart for portable convenience. The 25,000 Btu burner module can be built into an outdoor kitchen and the side burner attached to a cart. Wolf grills and modules can be ordered in natural or LP gas.
OUTDOOR GRILLS
OG30
OG36
OG42
OG54
OUTDOOR MODULES
BM13
SB13
BURNER MODULE SIDE BURNER
118 | Wolf Customer Care 800.222.7820
Outdoor Grills/Modules
Outdoor Grills and Modules
OUTDOOR GRILL
30" (762)
HOOD CLOSED
W
WIDTH
GRILL CART
27"
(686)
121/2" (318)
TO GRILLING SURFACE
273/4" (705)
21/2"
(64) CLEARANCE FOR OPEN
HOOD
12"
(305)
24" (610)
TO GRILL PLATFORM
361/2"
(927)
W
WIDTH
MAX DOOR/DRAWER CLEARANCE 22" (559)
3" (76)
273/4" (705)
BURNER MODULE / SIDE BURNER
30" (762)
103/4" (273)
13"
(330)
273/4" (705)
OUTDOOR GRILL OG30 OG36 OG42 OG54
GRILL CART CART30 CART36 CART42
W 30" (762) 36" (914) 42" (1067) 54" (1372)
W 30" (762) 36" (914) 42" (1067)
wolfappliance.com|119
Outdoor Grills/Modules
Planning Information
For portable applications, Wolf grill carts are designed specifically to fit grill models OG30, OG36, and OG42 and the side burner. Model OG54 is designed for built-in applications only.
For built-in applications, Wolf outdoor grills and the burner module are designed for easy placement into a built-in enclosure. For outdoor grills, installation in a combustible enclosure requires an insulating liner. For the burner module, an insulating liner is not required. The enclosure should be built according to specifications for your specific installation on the following pages. If the burner module is installed next to an outdoor grill, a minimum of 12" (305) is required between the units on the rotisserie motor side and 2" (51) on the opposite side. A rotisserie side conversion kit is available from an authorized Wolf dealer.
Model BM13 does not include a tank retention system and cannot be connected to a portable LP tank.
Optional stainless steel accessory doors and drawers are available for built-in applications. Refer to pages 124128.
Grill carts, insulating liners, and stainless steel doors and drawers are available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
The electrical outlet must be located within reach of the power cord. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock.
ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle Power Cord
grounded, 120 VAC, 60 Hz 15 amp dedicated circuit
3-prong grounding-type, GFCI 6' (1.8 m)
120 | Wolf Customer Care 800.222.7820
Outdoor Grills/Modules
GAS SUPPLY
Installation must comply with all applicable gas codes.
If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended.
If the outdoor grill is being connected to a whole house LP supply, the LP gas pressure regulator is not provided. It can be purchased from an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
GAS REQUIREMENTS
Gas Supply
Gas Inlet
NATURAL GAS Supply Pressure Min Line Pressure Max Regulator Pressure
LP GAS Supply Pressure Min Line Pressure Max Regulator Pressure
3/4" ID line
1/2" NPT female
WC 5" (12.5 mb) 7" (17.5 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
WC 10" (25 mb) 11" (27.4 mb) 14" (34.9 mb), .5 psi (3.5 kPa)
wolfappliance.com|121
Outdoor Grills/Modules
Outdoor Grill
NON-COMBUSTIBLE INSTALLATION
21/2" (64)
241/4" (616)
OPENING DEPTH
6"
(152)
13" G
(330)
31/2"
(89)
113/4"
(298) OPENING HEIGHT
TOP VIEW
W
OPENING WIDTH
6"
(152)
4"(102) G
GRILL OVERLAP
GRILL OPENING
13/16"
(21)
FRONT VIEW
COUNTERTOP OVERHANG
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
COMBUSTIBLE INSTALLATION
12" (305)
12"
(305)
26" (660)
OPENING DEPTH
103/4"
(273) CL
23/4" (70)
KNOCKOUT
G CL
5"
(127)
LINER OVERLAP
125/8"
(321) OPENING HEIGHT
TOP VIEW
W
OPENING WIDTH
LINER OPENING
13/16"
(21)
FRONT VIEW
COUNTERTOP OVERHANG
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area.
NON-COMBUSTIBLE ENCLOSURE OG30 OG36 OG42 OG54
W 281/2" (724) 341/2" (876) 401/2" (1029) 521/2" (1334)
COMBUSTIBLE ENCLOSURE OG30 OG36 OG42 OG54
W 331/2" (851) 391/2" (1003) 451/2" (1156) 571/2" (1461)
122 | Wolf Customer Care 800.222.7820
Outdoor Grills/Modules
Burner Module
INSTALLATION
12" (305)
G
241/4" (616)
OPENING DEPTH
6"
(152)
3" (76)
MODULE OVERLAP
10" (254)
OPENING HEIGHT
TOP VIEW
12" (305)
OPENING
G
8"
(203)
7"
(178)
MODULE OPENING
9/16"
(14)
FRONT VIEW
COUNTERTOP OVERHANG
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. An insulating liner is not required.
wolfappliance.com|123
Outdoor Accessories
Outdoor Accessories
ACCESS DOORS
SINGLE
DOUBLE
ACCESSORY DRAWERS AND DOORS
SINGLE DRAWER
2- OR 3-DRAWER DOOR/DRAWER
PAPER TOWEL DRAWER
TALL DRY STORAGE
SHORT DRY STORAGE
TRASH/RECYCLING DRAWER
124 | Wolf Customer Care 800.222.7820
Outdoor Accessories
Access Doors
DIMENSIONS
B
A
DOOR WIDTH 18" Single 30" Double 36" Double 42" Double 54" Double
23/4" (70)
INSTALLATION
1" (25) min
31/2" (89)
FINISHED RETURN
GRILL OPENING
W
TOP VIEW
203/4"
(527)
183/4"
(476)
19" (483)
OPENING HEIGHT
A 18" (457) 30" (762) 36" (914) 42" (1067) 54" (1372)
B 161/4" (413) 281/4" (718) 341/4" (870) 401/4" (1022) 521/4" (1327)
W OPENING WIDTH
FRONT VIEW
OPENING WIDTH 18" Single 30" Double 36" Double 42" Double 54" Double
W 161/2" (419) 281/2" (724) 341/2" (876) 401/2" (1029) 521/2" (1334)
IMPORTANT NOTE: The opening dimensions provided are for a standard installation. For a flush installation, refer to the overall dimensions and adjust the opening dimensions accordingly.
wolfappliance.com|125
Outdoor Accessories
Accessory Drawers and Doors
SINGLE DRAWER
27" (686)
2- OR 3-DRAWER
12" (305)
30" (762)
24"
(610)
23/4" (70)
113/8"
(289)
91/2"
(241)
PAPER TOWEL DRAWER
141/2" (368)
19"
(483)
18" (457)
23/4" (70)
10"
(254)
8"
(203)
18"
(457)
23/4" (70) 13" (330)
203/4"
(527)
19"
(483)
DRAWER/DOOR
281/2" (724)
30" (762)
18"
(457)
23/4" (70)
203/4"
(527)
19"
(483)
126 | Wolf Customer Care 800.222.7820
Outdoor Accessories
Accessory Drawers and Doors
TALL DRY STORAGE
22" (559)
24" (610)
193/4"
(502)
23/4" (70)
34"
(864)
32"
(813)
TRASH/RECYCLING DRAWER
16" (406)
D
18" (457)
23/4" (70)
26"
(660)
24"
(610)
SHORT DRY STORAGE
34" (864)
36" (914)
193/4"
(502)
23/4" (70)
203/4"
(527)
183/4"
(476)
DEPTH Single Double
D 221/4" (565) 251/4" (641)
wolfappliance.com|127
Outdoor Accessories
Accessory Drawers and Doors
INSTALLATION
D
OPENING DEPTH
1" (25) min
TOP VIEW
W
OPENING WIDTH
H
OPENING HEIGHT
31/2" (89)
FINISHED RETURN
W
FRONT VIEW
OPENING Single Drawer Paper Towel Drawer 2- or 3-Drawer Drawer/Door Tall Dry Storage Short Dry Storage Single Trash/Recycling Double Trash/Recycling
W 271/4" (692) 143/4 (375) 121/4" (311) 283/4" (730) 221/4" (565) 341/4" (870) 161/4" (413) 161/4" (413)
H 93/4" (248) 81/4" (210) 191/4" (489) 191/4" (489) 321/4" (819) 19" (483) 241/4" (616) 241/4" (616)
D 241/4" (616) 191/4" (489) 181/4" (464) 181/4" (464)
20" (508) 20" (508) 193/4" (502) 223/4" (578)
BASE SUPPORT 2- or 3-Drawer Drawer/Door Dry Storage
MIN 150 lb (68 kg) 150 lb (68 kg) 300 lb (136 kg)
IMPORTANT NOTE: The opening dimensions provided are for a standard installation. For a flush installation, refer to the overall dimensions and adjust the opening dimensions accordingly.
128 | Wolf Customer Care 800.222.7820
Outdoor Accessories
wolfappliance.com|129
Cooktop Ventilation Hoods
Cooktop Ventilation Hoods
Wolf cooktop ventilation hoods feature three distinct looks--black, stainless, and glass. Brilliant LED lighting illuminates your cooking surface while powerful multi-speed blowers whisk away smoke and odors. Dishwasher-safe filters can be removed easily for cleaning. Wall-mount and island hoods are crafted of stainless steel.
COOKTOP HOODS BLACK
VW30B WALL
VW36B WALL
VW45B WALL
VI42B ISLAND STAINLESS
VW30S WALL GLASS
VW36S WALL
VI42S ISLAND
VW36G WALL
VW45G WALL
VI45G ISLAND
130 | Wolf Customer Care 800.222.7820
Cooktop Ventilation Hoods
Cooktop Hoods
WALL HOODS--BLACK
113/4"
(298)
101/4"
(260)
291/8" (740)
TO
211/4"
391/4" (997)* (540)
W
WIDTH
21/4" (57)
*491/8" (1248) to 591/4" (1505) with accessory flue extension.
WIDTH VW30B VW36B VW45B
ISLAND HOOD--BLACK
133/4"
(349)
191/4"
(489)
W 30" (762) 36" (914) 45" (1143)
111/4"
(286)
235/8" (600)
TO
32" (813)*
231/4"
(591)
42"
(1067)
21/4" (57)
*461/4" (1175) to 55" (1397) with accessory flue extension.
261/2"
(673)
wolfappliance.com|131
Cooktop Ventilation Hoods
Cooktop Hoods
WALL HOODS--STAINLESS
113/4"
(298)
101/4"
(260)
291/8" (740)
TO
391/4" (997)*
211/4"
(540)
6"
(152)
W
WIDTH
*491/8" (1248) to 591/4" (1505) with accessory flue extension.
WIDTH VW30S VW36S
22"
(559)
W 30" (762) 36" (914)
ISLAND HOOD--STAINLESS
133/4"
(349)
111/4"
(286)
235/8" (600)
TO
32" (813)*
231/4"
(591)
6"
(152)
42"
(1067)
*461/4" (1175) to 55" (1397) with accessory flue extension.
261/2"
(673)
132 | Wolf Customer Care 800.222.7820
Cooktop Ventilation Hoods
Cooktop Hoods
WALL HOODS--GLASS
113/4"
(298)
101/4"
(260)
291/8" (740)
TO
211/4"
391/4" (997)* (540)
W
WIDTH
21/4" (57)
*491/8" (1248) to 591/4" (1505) with accessory flue extension.
WIDTH VW36G VW45G
191/4"
(489)
W 36" (914) 45" (1143)
ISLAND HOOD--GLASS
133/4"
(349)
111/4"
(286)
235/8" (600)
TO
231/4"
32" (813)* (591)
45"
(1143)
21/4" (57)
*461/4" (1175) to 55" (1397) with accessory flue extension.
261/2"
(673)
wolfappliance.com|133
Cooktop Ventilation Hoods
Planning Information
Wolf cooktop ventilation hoods are recommended for use with Wolf induction, electric and gas cooktops, and modules. For ranges and rangetops, a Wolf pro ventilation hood is recommended.
These hoods have a telescopic chimney flue. A flue extension is available through an authorized Wolf dealer.
Installation of the cooktop hood should be 24" (610) to 36" (914) from the bottom of the hood to the countertop.
Wall and island hoods require an internal, in-line, or remote blower assembly, available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Refer to Ventilation Suggestions on pages 154157. Cooktop hoods have a vertical discharge with 6" (152) round duct.
Consult a qualified HVAC professional for specific installation and ducting applications.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
For wall hoods, locate the electrical supply within the shaded area shown in the illustration below. For island hoods, locate the electrical supply on the ceiling inside the top of the hood. A separate circuit servicing only this appliance is required.
ELECTRICAL REQUIREMENTS Electrical Supply Service
grounded, 110/120 VAC, 60 Hz 15 amp dedicated circuit
LOCATE
ELECTRICAL
WITHIN
SHADED AREA
E
18"
(457)
24" (610) TO 36" (914) BOTTOM EDGE TO COUNTERTOP Electrical location for all wall hoods
134 | Wolf Customer Care 800.222.7820
Cooktop Ventilation Hoods
Ceiling-Mounted Hood
The ceiling-mounted hood is our most contemporary ventilation offering, nearly disappearing into its surroundings. It comes in two widths and is available in stainless steel or white glass. The hood ships with a remote control and can be operated using the remote control or the control panel. The control panel is recessed into the right side of the hood. The dishwasher-safe filters can be removed easily for cleaning.
CEILING-MOUNTED HOOD STAINLESS STEEL
VC36S WHITE GLASS
VC48S
VC36W
VC48W
wolfappliance.com|135
Cooktop Ventilation Hoods
Ceiling-Mounted Hood
STAINLESS STEEL
71/4"
(184)
A
131/4"
(337)
W
71/4" (184)
TO
123/4" (324) 5" (127)
1/16" (2)
131/4"
(337)
21" (533)
DIMENSIONS 36" Hood 48" Hood
W 351/2" (902) 471/4" (1200)
A 331/8" (841) 441/8" (1121)
WHITE GLASS
71/4"
(184)
A
131/4"
(337)
W
DIMENSIONS 36" Hood 48" Hood
71/4" (184)
TO
123/4" (324) 5" (127)
1/4" (6)
131/4"
(337)
21" (533)
W 351/2" (902) 471/4" (1200)
A 331/8" (841) 441/8" (1121)
136 | Wolf Customer Care 800.222.7820
Cooktop Ventilation Hoods
Planning Information
Installation of the ceiling-mounted hood should be 36" (914) to 84" (2134) from the bottom of the hood to the countertop.
The hood can be operated using the remote control or the control panel located on the right side of the hood.
The hood is shipped without a blower assembly. Internal, in-line, and remote blowers are available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Refer to Ventilation Suggestions on pages 154157.
Ceiling-mounted hoods include a 6" (152) round discharge for internal blowers and a 10" (254) round discharge for inline and remote blowers. For an internal blower, the blower box can be rotated to discharge right, left, front, or rear. For an in-line or remote blower, the discharge is vertical only.
Consult a qualified HVAC professional for specific installation and ducting applications.
RECIRCULATING APPLICATION The ceiling-mounted hood with an internal blower only, can be installed in a recirculating application. The air discharge must be a minimum of 40" (1016) from every side of the hood. Refer to the illustration below. The ductwork and vent cover are not provided. A recirculation kit, available through an authorized Wolf dealer, is required.
40" (1016)
MIN
Recirculating application
wolfappliance.com|137
Cooktop Ventilation Hoods
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown in the illustration below. Allow a minimum 12" (305) Romex® wire for connection. A separate circuit servicing only this appliance is required.
ELECTRICAL REQUIREMENTS Electrical Supply Service
grounded, 120 VAC, 60 Hz 15 amp dedicated circuit
Opening Dimensions
CEILING-MOUNTED HOOD
Refer to the chart and illustrations below for opening dimensions and typical framing. Framing must be able to support a minimum of 100 lb (45 kg).
HOOD 36" Hood 48" Hood
W 341/2" (873) 461/4" (1175)
E 36" (914) TO 84" (2134) BOTTOM EDGE TO COUNTERTOP Electrical location
20"
(508)
W
Opening dimensions
123/8" (314) MIN TO 173/4" (451) MAX
Support framing (typical)
138 | Wolf Customer Care 800.222.7820
Cooktop Ventilation Hoods
Under-Cabinet Hood Insert
The under-cabinet hood insert mounts inside a cabinet. It comes in two widths and is available in stainless steel. The hood ships with a remote control and can be operated using the remote control or the control panel. The dishwasher-safe filters can be removed easily for cleaning.
UNDER-CABINET HOOD INSERT
DIMENSIONS
W
VU24S
VU30S
WIDTH 24" Hood Insert 30" Hood Insert
133/4"
(349)
1/2"
113/4" (299)
(13)
W 201/2" (521) 275/8" (702)
wolfappliance.com|139
Cooktop Ventilation Hoods
Planning Information
The under-cabinet hood insert should be installed 24" (610) to 36" (914) from the bottom of the hood to the countertop.
The hood can be operated using the remote control or the control panel located at the front of the hood bottom.
The hood requires a 300 or 600 CFM internal blower, available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Refer to Ventilation Suggestions on pages 154157. The hood includes a 6" (152) round discharge for an internal blower.
Consult a qualified HVAC professional for specific installation and ducting applications.
RECIRCULATING APPLICATION
The hood can be installed in a recirculating application. Refer to the illustration below. Ductwork is not provided.
Recirculating filters, available through an authorized Wolf dealer, are required.
HORIZONTAL DISCHARGE
DISCHARGE ABOVE CABINET
Recirculating application
140 | Wolf Customer Care 800.222.7820
Cooktop Ventilation Hoods
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply above or in an adjacent cabinet within reach of the power cord. Refer to the illustration below. A separate circuit servicing only this appliance is required.
ELECTRICAL REQUIREMENTS Electrical Supply Service Power Cord
grounded, 120 VAC, 60 Hz 15 amp dedicated circuit 4' (1.2 m)
Opening Dimensions
UNDER-CABINET HOOD INSERT
Refer to the chart and illustration below for opening dimensions. The cabinet must be able to support a minimum of 100 lb (45 kg).
OPENING WIDTH 24" Hood Insert 30" Hood Insert
W 191/2" (495) 265/8" (676)
E
E
24" (610) TO 36" (914)
BOTTOM EDGE TO COUNTERTOP
Electrical location
W Opening dimensions
101/4"
(260)
wolfappliance.com|141
Downdraft Ventilation
Downdraft Ventilation
Constructed of heavy duty stainless steel, the Wolf downdraft rises from the countertop to whisk away odor and smoke into stainless steel, mesh filters and can be lowered beneath the countertop when not in use. Downdrafts integrate perfectly with transitional induction and electric cooktops, gas cooktops, and some modules, they can also be installed with certain sealed burner rangetops.
DOWNDRAFTS
DD30
DD36
DD45
142 | Wolf Customer Care 800.222.7820
Downdraft Ventilation
Downdraft Ventilation
DIMENSIONS
W
2"
DOWNDRAFT WIDTH
(51)
14"
(356)
13"
(330)
15"
(381)
13"
(330)
283/4"
(730)
10"
(254)
63/4"
(172)
23/8"
(60)
A
CHIMNEY WIDTH
21/2"
(64)
NOTE: Shown with front mounted internal blower with 6" (152) round discharge, dashed line represents rear mount.
WIDTH DD30 DD36 DD45
W 30" (762) 36" (914) 45" (1143)
A 261/2" (673) 321/2" (826) 381/2" (978)
wolfappliance.com|143
Downdraft Ventilation
Planning Information
Wolf downdrafts can be installed with most Wolf cooktops, but are not compatible with the grill, steamer, and fryer modules. Downdrafts can be installed with sealed burner rangetop models SRT304 and SRT366.
For installation with a Wolf cooktop, a minimum 251/8" (638) deep flat countertop is required.
For installation with a sealed burner rangetop or 30" (762) or 36" (914) contemporary cooktop, an accessory trim kit is required. Contact an authorized Wolf dealer for details. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
The remote-mounted control module can be positioned horizontally or vertically. It must be located within 9' (2.7 m) of the downdraft assembly and a minimum 3" (76) from the edge of the cooktop cutout.
Consult a qualified HVAC professional for specific installation and ducting applications.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
Certain installations may require the electrical supply be placed in an adjacent cabinet.
ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle Power Cord
grounded, 120 VAC, 60 Hz 15 amp dedicated circuit 3-prong grounding-type 21/2' (.8 m)
BLOWERS
Internal, in-line, and remote blowers are available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. Refer to Ventilation Suggestions on pages 154157.
Internal blowers have a 6" (152) round discharge, can be front or rear mounted, and can be discharged in any direction by rotating the blower box. In-line and remote blowers have a 10" (254) discharge and can be discharged from the front or rear.
144 | Wolf Customer Care 800.222.7820
Downdraft Ventilation
Downdraft
INSTALLATION WITH STANDARD INSTALLED COOKTOP
211/16" (68)
W
DOWNDRAFT CUTOUT WIDTH
E 81/4" (210)*
COOKTOP CUTOUT TOP VIEW
81/4"
(210)*
211/4"
(540)
211/4"
(540)
233/8"
(594)
E
SIDE VIEW
FRONT VIEW
*6" (152) back from countertop cutout when internal blower is rear mounted.
NOTE: Internal blower 6" (152) round, side, rear or bottom discharge. In-line and remote blower 10" (254) round, rear discharge. Centerline indicates center of downdraft cutout.
CUTOUT WIDTH DD30 DD36 DD45
W 271/2" (699) 331/2" (851) 391/2" (1003)
wolfappliance.com|145
Downdraft Ventilation
Downdraft
INSTALLATION WITH FLUSH INSTALLED COOKTOP
25/16" (59)
W
DOWNDRAFT CUTOUT WIDTH
E 81/4" (210)*
COOKTOP CUTOUT TOP VIEW
81/4"
(210)*
211/4"
(540)
211/4"
(540)
233/8"
(594)
E
SIDE VIEW
FRONT VIEW
*6" (152) back from countertop cutout when internal blower is rear mounted.
NOTE: Internal blower 6" (152) round, side, rear, or bottom discharge. In-line and remote blower 10" (254) round, rear discharge. Centerline indicates center of downdraft cutout.
CUTOUT WIDTH DD30 DD36
W 271/2" (699) 331/2" (851)
146 | Wolf Customer Care 800.222.7820
Downdraft Ventilation
Downdraft
INSTALLATION WITH SEALED BURNER RANGETOP
211/16" (68)
W
DOWNDRAFT CUTOUT WIDTH
E 81/4" (210)*
19" (483)
PLATFORM DEPTH
81/4"
(210)*
211/4"
(540)
RANGETOP OPENING TOP VIEW
211/4"
(540)
233/8"
(594)
E
SIDE VIEW
FRONT VIEW
*6" (152) back from countertop cutout when internal blower is rear mounted.
NOTE: Internal blower 6" (152) round, side, rear, or bottom discharge. In-line and remote blower 10" (254) round, rear discharge. Centerline indicates center of downdraft cutout.
CUTOUT WIDTH DD30 DD36
W 271/2" (699) 331/2" (851)
wolfappliance.com|147
Pro Ventilation Hoods
Pro Ventilation Hoods
Professional heritage shines through in Wolf professional-style ventilation. Exteriors are heavy-duty, welded stainless steel, so finely hand-finished they appear seamless. Pro hoods are available in a variety of widths. Stainless steel baffle filters and halogen lighting extend the professional look and back it up with pro-level performance. All pro ventilation hoods are crafted of stainless steel. A hood liner is also available for custom applications. The outdoor wall hood is specifically designed for outdoor use.
PRO HOODS WALL HOODS
LOW-PROFILE
CHIMNEY ISLAND HOOD
ISLAND HOOD LINER
19"/22" DEEP
24"/27" DEEP OUTDOOR
148 | Wolf Customer Care 800.222.7820
Pro Ventilation Hoods
Pro Hoods
LOW-PROFILE WALL HOOD
W
WIDTH
10" (254)
12"
(305)
22" (559)
4" (102)
24" DEEP WALL HOOD
W
WIDTH
18"
(457)
12"
(305)
24" (610)
4" (102)
27" DEEP WALL HOOD
W
WIDTH
18"
(457)
12"
(305)
27" (686)
4" (102)
WIDTH
LOW-PROFILE WALL HOOD
W
30" (762), 36" (914), 42" (1067), 48" (1219)
24" DEEP WALL HOOD
W
30" (762), 36" (914), 42" (1067), 48" (1219) 54" (1372), 60" (1524), 66" (1676)
27" DEEP WALL HOOD
W
30" (762), 36" (914), 42" (1067), 48" (1219) 54" (1372), 60" (1524), 66" (1676)
wolfappliance.com|149
Pro Ventilation Hoods
Pro Hoods
WALL CHIMNEY HOOD
WIDTH MINUS 18" (457)
W
WIDTH
ISLAND HOOD
WIDTH MINUS 18" (457)
W
WIDTH
HOOD LINER
WIDTH MINUS 6" (152)
W
WIDTH
18"
(457)
131/2"
(343)
24" (610)
4" (102)
18"
(457)
13"
(330)
34" (864)
4" (102)
121/8"
(308)
12"
(305)
193/8" (492) 225/8" (575)
4" (102)
WIDTH WALL CHIMNEY HOOD ISLAND HOOD HOOD LINER
W 36" (914), 42" (1067), 48" (1219), 54" (1372)
W 36" (914), 42" (1067), 54" (1372), 66" (1676)
W 343/8" (873), 403/8" (1026), 463/8" (1178)
523/8" (1330), 583/8" (1483)
150 | Wolf Customer Care 800.222.7820
Pro Ventilation Hoods
Pro Hoods
OUTDOOR WALL HOOD
18"
(457)
139/16"
(346)
W
WIDTH
WIDTH OUTDOOR WALL HOOD
33" (838)
W 36" (914), 48" (1219), 60" (1524)
4" (102)
wolfappliance.com|151
Pro Ventilation Hoods
Planning Information
Pro ventilation hoods and hood liners are recommended for use with all Wolf cooking appliances. Wall hoods should be at least as wide as the cooking surface and island hoods should be 3" (76) wider on each side.
For optimal performance in wall hood applications, a pro 27" deep wall hood is recommended for use with ranges and rangetops with a charbroiler or griddle.
Installation of all Pro hoods except the outdoor wall hood should be 30" (762) to 36" (914) from the bottom of the hood to the countertop. Installation of the outdoor wall hood should be 36" (914) to 42" (1067) from the bottom of the hood to the countertop.
Pro hoods and hood liners are shipped without a blower assembly. Internal, in-line, and remote blowers are available through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. The blower will vary in size and is dictated by the cooking unit, volume of air, and length of the duct run. Refer to Ventilation Suggestions on pages 154157.
Pro hoods accommodate a 10" (254) round duct. Lowprofile wall hoods allow for an adjustable discharge. All other pro hoods have a vertical discharge. For the 24" and 27" deep wall hoods, a horizontal discharge kit is available through an authorized Wolf dealer.
Consult a qualified HVAC professional for specific installation and ducting applications.
Optional stainless steel duct covers in a variety of heights are available for pro wall and island hoods through an authorized Wolf dealer.
RECIRCULATING APPLICATION
Low-profile, 24" deep, and 27" deep wall hoods with an internal blower (600 CFM or less), 30" (762) and 36" (914) widths only, can be used in a non-ducted application with a recirculating filter. In this installation, kitchen air is purified through the filters and returned as clean air into the room. A recirculation kit, available through an authorized Wolf dealer, is required.
CUSTOM HOOD APPLICATIONS
Wolf pro hood liners are for use in custom hood applications. The decorative hood can be created out of wood, plaster, tile, or metal. The shape of the hood is not critical, however, the bottom of the hood and liner must be on the same plane. The height of the liner does not need to accommodate the entire height of the decorative hood.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on the following page. A separate circuit servicing only this appliance is required.
For the outdoor wall hood, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock.
ELECTRICAL REQUIREMENTS Electrical Supply Service
grounded, 120 VAC, 60 Hz 15 amp dedicated circuit
152 | Wolf Customer Care 800.222.7820
Pro Ventilation Hoods
Installation
LOW-PROFILE / 24" DEEP / 27" DEEP WALL HOOD
E
6"
(152)
5"
(127)
OUTDOOR WALL HOOD
E
6"
(152)
5"
(127)
30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP
WALL CHIMNEY HOOD
E
6"
(152)
5"
(127)
36" (914) TO 42" (1067) BOTTOM EDGE TO COUNTERTOP
30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP
ISLAND HOOD
ELECTRICAL LOCATION THROUGH TOP OF HOOD
30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP
HOOD LINER
DECORATIVE HOOD
121/2"
(318)
E
75/8"
(194)
30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP
wolfappliance.com|153
Ventilation Suggestions
Blower Assemblies
For Wolf ventilation hoods and downdrafts that do not include a blower assembly, an internal, in-line, or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements, and homeowner preferences. Internal, in-line, and remote blowers are avail able through an authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
Ventilation suggestions on the following pages provide Wolf product CFM and blower options for each ventilation hood and downdraft.
Refer to the illustrations below for dimensions of Wolf inline and remote blowers. Installation instructions shipped with each Wolf ventilation product provide detailed specifications. These instructions can also be found on our website, wolfappliance.com/specs.
600 CFM IN-LINE
113/4"
(298)
24 3/8"
(619)
181/2"
(470)
41/2"
(114)
211/2"
(546)
121/4"
(311)
1100 CFM IN-LINE
24 7/8"
(632)
18"
(457)
12"
(305)
8"
(203)
22"
(559)
18"
(457)
600 / 900 CFM REMOTE
281/4"
(718)
151/2"
(394)
20 3/4"
(527)
10" (254)
DIAMETER
241/2"
(622)
14"
(356)
24 3/4"
(629)
4 3/4"
(121)
1200 CFM REMOTE
291/2"
(749)
14 3/4"
(375)
18" (457)
10"
(254)
10" (254)
DIAMETER
291/2"
(749)
1500 CFM REMOTE
291/2"
(749)
14 3/4"
(375)
21" (533)
10"
(254)
10" (254)
DIAMETER
291/2"
(749)
101/8"
(257)
22"
(559)
71/4"
(184)
10 3/8"
(264)
25"
(635)
71/4"
(184)
154 | Wolf Customer Care 800.222.7820
Ventilation Suggestions
Wolf Product CFM
CFM COOKTOP / MODULE CI152TF/S CE152TF/S CG152TF/S SM15TF/S FM15TF/S GM15TF/S TM15TF/S MM15TF/S CI243TF/S CI243C/B CG243TF/S CI304TF/S CI304T/S CI304C/B CE304T/S CE304C/B CG304T/S CG304P/S CI365TF/S CI365T/S CI365C/B CE365T/S CE365C/B CG365T/S CG365P/S CG365C/S DUAL FUEL RANGE DF304 DF366 DF364C DF364G DF486C DF486G DF484CG DF484DG DF484F DF606CG DF606DG DF606F DF604CF DF604GF GAS RANGE GR304 GR366 GR364C GR364G GR488 GR486C GR486G GR484CG GR484DG GR606CG GR606DG GR606F INDUCTION RANGE IR304 IR365 SEALED BURNER RANGETOP SRT304 SRT366 SRT364C SRT364G SRT362W SRT486C SRT486G SRT484CG SRT484DG SRT484F SRT484W
COOKTOP HOOD DOWNDRAFT
PRO HOOD
300
600
300
300
300
300
600
300
300
300
300
600
300
300
600
300
300
600
300
300
600
300
300
600
300
300
600
300
500 800 1100 1500
500 800 1100 1500
300
300
300
300
600
500
600
800
800
800
Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf & Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries. All other trademarks are property of their respective owners in the United States and other countries.
wolfappliance.com|155
Ventilation Suggestions
Wolf Ventilation Blower Options
INTERNAL BLOWER (CFM)
300 INT* 400 INT*
COOKTOP HOOD
VW30B VW36B VW45B VI42B
·
VW30S VW36S VI42S
·
VW36G VW45G VI45G
·
CEILING-MOUNTED HOOD
VC36S VC36W VC48S VC48W
UNDER-CABINET HOOD INSERT
VU24S VU30S
·
DOWNDRAFT
DD30 DD36 DD45
PRO LOW-PROFILE WALL HOOD
PW302210 PW362210
PW422210 PW482210
PRO 24" WALL HOOD
PW302418 PW362418 PW422418
·
·
PW482418 PW542418
·
·
PW602418 PW662418
·
·
PRO 27" WALL HOOD
PW302718 PW362718 PW422718
·
·
PW482718 PW542718
·
·
PW602718 PW662718
·
·
PRO WALL CHIMNEY HOOD
PWC362418 PWC422418
·
·
PWC482418 PWC542418
·
·
PRO ISLAND HOOD
PI363418 PI423418
·
·
PI543418
·
·
PI663418
·
·
PRO HOOD LINER
PL341912 PL342212 PL401912 PL402212
·
·
PL461912 PL462212
·
·
PL521912 PL522212
·
·
PL581912 PL582212
·
·
OUTDOOR WALL HOOD
PW363318O PW483318O PW603318O
*For make-up air restricted applications. Capture and performance may be reduced.
500 INT
· ·
600 INT
· · ·
·
·
·
· · ·
· · ·
· ·
· · ·
· · · ·
800 INT 1200 INT
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
156 | Wolf Customer Care 800.222.7820
Ventilation Suggestions
Wolf Ventilation Blower Options
IN-LINE / REMOTE BLOWER (CFM) COOKTOP HOOD VW30B VW36B VW45B VI42B VW30S VW36S VI42S VW36G VW45G VI45G CEILING-MOUNTED HOOD VC36S VC36W VC48S VC48W UNDER-CABINET HOOD INSERT VU24S VU30S DOWNDRAFT DD30 DD36 DD45 PRO LOW-PROFILE WALL HOOD PW302210 PW362210 PW422210 PW482210 PRO 24" WALL HOOD PW302418 PW362418 PW422418 PW482418 PW542418 PW602418 PW662418 PRO 27" WALL HOOD PW302718 PW362718 PW422718 PW482718 PW542718 PW602718 PW662718 PRO WALL CHIMNEY HOOD PWC362418 PWC422418 PWC482418 PWC542418 PRO ISLAND HOOD PI363418 PI423418 PI543418 PI663418 PRO HOOD LINER PL341912 PL342212 PL401912 PL402212 PL461912 PL462212 PL521912 PL522212 PL581912 PL582212 OUTDOOR WALL HOOD PW363318O PW483318O PW603318O
600 IL
· · ·
·
·
· ·
· · ·
· · ·
· ·
· · ·
· · · ·
1100 IL
600 REM 900 REM 1200 REM 1500 REM
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
wolfappliance.com|157
Warranty
Wolf Appliance Residential Limited Warranty
FOR RESIDENTIAL USE FULL TWO YEAR WARRANTY* For two years from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf Factory Certified Service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours. LIMITED FIVE YEAR WARRANTY For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: gas burners (excludes appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators. If the owner uses Wolf Factory Certified Service, the service provider will repair or replace these parts with the owner paying for all other costs, including labor. If the owner uses non-certified service, the owner must contact Wolf Appliance, Inc. (using the information below) to receive repaired or replacement parts. Wolf Appliance will not reimburse the owner for parts purchased from non-certified service or other sources. TERMS APPLICABLE TO EACH WARRANTY The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair. THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE, INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state. To receive parts and/or service and the name of Wolf Factory Certified Service nearest you, contact Wolf Appliance, Inc., P.O. Box 44848, Madison, WI 53744; check the Product Support section of our website, wolfappliance.com, email us at customerservice@ subzero.com or call 800-222-7820. *Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty for cosmetic defects. *Replacement filters for ventilation hood recirculating kits are not covered by the product warranty.
158 | Wolf Customer Care 800.222.7820
Warranty
Wolf Appliance Outdoor Limited Warranty*
FOR RESIDENTIAL USE FULL ONE YEAR WARRANTY** For one year from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf Factory Certified Service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours. LIMITED FIVE YEAR WARRANTY For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: stainless steel briquette trays, gas valves, drip pans, electronic control boards and electric heating elements. If the owner uses Wolf Factory Certified Service, the service provider will repair or replace these parts with the owner paying for all other costs, including labor. If the owner uses non-certified service, the owner must contact Wolf Appliance, Inc. (using the information below) to receive repaired or replacement parts. Wolf Appliance will not reimburse the owner for parts purchased from non-certified service or other sources. LIMITED LIFETIME WARRANTY For the life of the product, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: all stainless steel components (excludes surface corrosion, scratches, discoloration, weather and atmospheric related staining and minor surface rust and oxidation). If the owner uses Wolf Factory Certified Service, the service provider will repair or replace these parts with the owner paying for all other costs, including labor. If the owner uses non-certified service, the owner must contact Wolf Appliance, Inc. (using the information below) to receive repaired or replacement parts. Wolf Appliance will not reimburse the owner for parts purchased from non-certified service or other sources. TERMS APPLICABLE TO EACH WARRANTY The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair. THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE, INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state. To receive parts and/or service and the name of Wolf Factory Certified Service nearest you, contact Wolf Appliance, Inc., P.O. Box 44848, Madison, WI 53744; check the Product Support section of our website, wolfappliance.com, email us at customerservice@ subzero.com or call 800-222-7820. *Product must be approved for outdoor use, designated by model and serial number. **Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty for cosmetic defects.