EMC TRF Template

Tara Mitchell

Test report

Mason America, Inc. A4100 Mason Wearable 2AJZP-A4100 2AJZPA4100 a4100

GetApplicationAttachment.html?id=6038175
TEST REPORT

Report Reference No. .................... : CHTEW2207011002 Report Verification:

Project No................................. SHT2207037103EW

FCC ID............................................. : 2AJZP-A4100

Applicant's name ........................... : Mason America, Inc

Address.............................................: 2101 4TH AVE STE 1550 SEATTLE, WA 98121-2316

Test item description .................... : Mason Wearable

Trade Mark .......................................: Mason

Model/Type reference.......................: A4100

Listed Model(s) .................................: -

Standard ......................................... : 47 CFR FCC Part 15 Subpart B

Date of receipt of test sample...........: Jul.14, 2022

Date of testing..............................: Jul.14, 2022- Jul.31, 2022

Date of issue.................................: Aug.01, 2022

Result .................. ........................: Pass

Compiled by

( position+printed name+signature)..: File administrators Fanghui Zhu

Supervised by

( position+printed name+signature)..: Project Engineer Caspar Chen

Approved by ( position+printed name+signature)..:

RF Manager Hans Hu

Testing Laboratory Name ............. : Shenzhen Huatongwei International Inspection Co., Ltd.
Address.............................................: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
The test report merely corresponds to the test sample.

Page: 1 of 15

Report No.: CHTEW2207011002

Page: 2 of 15

Issued: 2022-08-01

Contents

1.

TEST STANDARDS AND REPORT VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1. Test Standards

3

1.2. Report version information

3

2.

TEST DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3.

SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.1. Client Information

5

3.2. Product Description

5

3.3. EUT operation mode

5

4.

TEST ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4.1. Testing Laboratory Information

6

4.2. Environmental conditions

6

4.3. Statement of the measurement uncertainty

6

4.4. Equipments Used during the Test

7

5.

TEST CONDITIONS AND RESULTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

5.1. Conducted Emissions Test

8

5.2. Radiated Emissions Test

10

6.

TEST SETUP PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 4

7.

EXTERNAL AND INTERNAL PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 5

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002

Page: 3 of 15

Issued: 2022-08-01

1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards: 47 CFR FCC Part 15 Subpart B - Unintentional Radiators ANSI C63.4: 2014 ­ American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz

1.2. Report version information

Revision No.

Date of issue

N/A

2022-08-01

Description
Add components (screen, NFC IC, memory, camera IC), Retest all test items based on the report CHTEW21110244

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002

Page: 4 of 15

2. TEST DESCRIPTION
Test Item Conducted Emissions Radiated Emissions

Section in CFR 47 15.107(a) 15.109(a)

Note: The measurement uncertainty is not included in the test result.

Issued: 2022-08-01

Result PASS PASS

Test Engineer Junman Wang Hongbin Zhong

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002

Page: 5 of 15

Issued: 2022-08-01

3. SUMMARY

3.1. Client Information

Applicant:

Mason America, Inc

Address:

2101 4TH AVE STE 1550 SEATTLE, WA 98121-2316

Manufacturer:

Mason America, Inc

Address:

2101 4TH AVE STE 1550 SEATTLE, WA 98121-2316

3.2. Product Description

Name of EUT:

Mason Wearable

Trade Mark:

Mason

Model No.:

A4100

Listed Model(s)

-

Power supply:

DC 3.85V

Adapter information:

Model: TPA-147C050100UU01 Input: AC100-240V, 50/60Hz, 0.2A Output: 5.0Vdc, 1.0A

3.3. EUT operation mode

Test mode

Describe

Camera recording mode

Keep the EUT in Camera recording status

Video Playing mode

Keep the EUT in Video Playing status

Pre-scan all of above modes. Only show Camera recording mode which is the worst case on the report.

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002

Page: 6 of 15

Issued: 2022-08-01

4. TEST ENVIRONMENT

4.1. Testing Laboratory Information

Laboratory Name Laboratory Location Connect information:
Qualifications

Shenzhen Huatongwei International Inspection Co., Ltd.

1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China

Tel: 86-755-26715499

E-mail: cs@szhtw.com.cn

http://www.szhtw.com.cn

Type

Accreditation Number

FCC

762235

4.2. Environmental conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature:

15~35°C

Relative Humidity:

30~60 %

Air Pressure:

950~1050mba

4.3. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16 - 4 ,,Specification for radio disturbance and immunity measuring apparatus and methods ­ Part 4: Uncertainty in EMC Measurements" and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:

Test

Range

Measurement Uncertainty

Notes

Radiated Emissions

30~1000MHz

4.90 dB

(1)

Radiated Emissions

1~18GHz

4.96 dB

(1)

Conducted Disturbance

0.15~30MHz

3.02 dB

(1)

(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence

level using a coverage factor of k=1.96.

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002

Page: 7 of 15

Issued: 2022-08-01

4.4. Equipments Used during the Test

 Conducted Emission

Used Test Equipment

Manufacturer

Equipment No. Model No.

Serial No.

 Shielded Room Albatross projects



EMI Test Receiver

R&S

 Artificial Mains SCHWARZBECK

HTWE0114 HTWE0111 HTWE0113

N/A ESCI NNLK 8121

N/A 101247
573

 Pulse Limiter

R&S

HTWE0033

ESH3-Z2

100499



RF Connection Cable

HUBER+SUHNER

HTWE0113-02

ENVIROFLE X_142

EF-NMBNCM-2M

 Test Software

R&S

N/A

ES-K1

N/A

Last Cal. Date (YY-MM-DD)
2021/9/13 2021/9/13 2021/9/13 2021/9/13 2021/9/13
N/A

Next Cal. Date (YY-MM-DD)
2022/9/12 2022/9/12 2022/9/12 2022/9/12 2022/9/12
N/A

 Radiated emission-6th test site

Used Test Equipment



Semi-Anechoic Chamber



EMI Test Receiver

 Loop Antenna



Ultra-Broadband Antenna

 Pre-Amplifer



RF Connection Cable



RF Connection Cable

 Test Software

Manufacturer

Equipment No.

Albatross projects R&S R&S
SCHWARZBECK SCHWARZBECK

HTWE0127 HTWE0099 HTWE0170 HTWE0123 HTWE0295

HUBER+SUHNER HTWE0062-01

HUBER+SUHNER HTWE0062-02

R&S

N/A

Model No. SAC-3m-02
ESCI HFH2-Z2 VULB9163 BBV 9742
N/A
SUCOFLEX104 ES-K1

Serial No. C11121 100900 100020
538 N/A N/A
501184/4 N/A

Last Cal. Date (YY-MM-DD) 2018/09/30 2021/09/14 2021/04/06 2021/04/06 2021/11/05 2022/02/25
2022/02/25 N/A

Next Cal. Date (YY-MM-DD) 2022/09/29 2022/09/13 2024/04/05 2024/04/05 2022/11/04 2023/02/24
2023/02/24 N/A

 Radiated emission-7th test site

Used Test Equipment

Manufacturer

Equipment No.



Semi-Anechoic Chamber

Albatross projects



Spectrum Analyzer

R&S

HTWE0122 HTWE0098

 Horn Antenna

SCHWARZBECK

HTWE0126



Broadband Horn Antenna

SCHWARZBECK

HTWE0103

 Pre-amplifier

CD

HTWE0071



Broadband Preamplifier

SCHWARZBECK

HTWE0201



RF Connection Cable

HUBER+SUHNER

HTWE0120-01



RF Connection Cable

HUBER+SUHNER

HTWE0120-02



RF Connection Cable

HUBER+SUHNER

HTWE0119-05



RF Connection Cable

HUBER+SUHNER

HTWE0120-04

 Test Software

Audix

N/A

Model No. SAC-3m-01

Serial No. C11121

Last Cal. Date (YY-MM-DD)
2018/09/27

FSP40
9120D
BBHA9170
PAP-0102
BBV 9718
6m 18GHz S Serisa 6m 3GHz RG Serisa 6m 3GHz RG Serisa 6m 3GHz RG Serisa E3

100597 1011
BBHA9170472 12004
9718-248 N/A N/A N/A N/A N/A

2021/09/13 2020/04/01 2020/04/27 2021/11/05 2022/02/28 2022/02/25 2022/02/25 2022/02/25 2022/02/25
N/A

Next Cal. Date (YY-MM-DD) 2022/09/26 2022/09/12 2023/03/31 2023/04/26 2022/11/04 2023/02/27 2023/02/24 2023/02/24 2023/02/24 2023/02/24
N/A

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002

Page: 8 of 15

Issued: 2022-08-01

5. TEST CONDITIONS AND RESULTS

5.1. Conducted Emissions Test

LIMIT

FCC CFR Title 47 Part 15 Subpart B Section 15.107:

Frequency range (MHz)
0.15-0.5 0.5-5 5-30
* Decreases with the logarithm of the frequency.

Quasi-peak 66 to 56* 56 60

Limit (dBuV)

Average 56 to 46*
46 50

TEST CONFIGURATION

TEST PROCEDURE
1. The EUT was setup according to ANSI C63.4:2014 2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 10 cm above the conducting
ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces of EUT were at least 10 cm from any other grounded conducting surface. 3. The EUT and simulators are connected to the main power through a line impedance stabilization network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment. 4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block diagram of the test setup and photographs) 5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was individually connected through a LISN to the input power source. 6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and forth at the center of the lead to form a bundle not exceeding 40 cm in length. 7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a receiver bandwidth of 9 kHz. 8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE: Please refer to the clause 3.3

TEST RESULTS

Passed

Not Applicable

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002 Test Line:

Page: 9 of 15 L

Issued: 2022-08-01

Test Line:

N

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002

Page: 10 of 15

5.2. Radiated Emissions Test
LIMIT

FCC CFR Title 47 Part 15 Subpart B Section 15.109

Frequency

Limit (dBuV/m @3m)

30MHz-88MHz

40.00

88MHz-216MHz

43.50

216MHz-960MHz

46.00

960MHz-1GHz

54.00

Above 1GHz

54.00 74.00

TEST CONFIGURATION

 30MHz ~ 1GHz

Issued: 2022-08-01
Value Quasi-peak Quasi-peak Quasi-peak Quasi-peak
Average Peak

 Above 1GHz

TEST PROCEDURE
1. The EUT was tested according to ANSI C63.4:2014. 2. The EUT is placed on a turn table which is 0.8 meter above ground. 3. The turn table is rotated 360 degrees to determine the position of the maximum emission level. 4. The EUT waspositioned such that the distance from antenna to the EUT was 3 meters. 5. The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
repeated for both horizontal and vertical polarization of the antenna. 6. Use the following spectrum analyzer settings
(1) Span shall wide enough to fully capture the emission being measured; (2) Below 1GHz,
RBW=120KHz, VBW=300KHz, Sweep=auto, Detector function=peak, Trace=max hold; If the emission level of the EUT measured by the peak detectoris 3 dB lower than the applicable limit, the peak emission level will be reported. Otherwise, theemission measurement will be repeated using the quasi-peak detector and reported. (3) From 1GHz to 5th harmonic, RBW=1MHz, VBW=3MHz

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002

Page: 11 of 15

Issued: 2022-08-01

TEST MODE: Please refer to the clause 3.3

TEST RESULTS

Passed

Not Applicable

Note: Final Level =Receiver Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor The emission levels of frequency above 6GHz are very lower than limit and not show in test report.

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002 Polarization:

Page: 12 of 15 Horizontal

Issued: 2022-08-01

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002 Polarization:

Page: 13 of 15 Vertical

Issued: 2022-08-01

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002

Page: 14 of 15

6. TEST SETUP PHOTOS OF THE EUT
Conducted Emissions (AC Mains)

Issued: 2022-08-01

Radiated Emissions (30MHz-1GHz)

Radiated Emissions (Above 1GHz)

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

Report No.: CHTEW2207011002

Page: 15 of 15

Issued: 2022-08-01

7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT
Reference to the test report No.: CHTEW22070110

--------End of Report--------

Shenzhen Huatongwei International Inspection Co., Ltd.

Report Template Version: V03 (2021-01)

