AVENAR detector 4000

FAP-/FAH-425 series

Product Description

The AVENAR detector 4000 combines standard detection methods like scattered light and temperature measurement with gas detection technology. It utilizes intelligent signal processing (ISP) to evaluate signals from optical, thermal, and chemical sensors. Alarms are triggered based on the specific characteristics of the operating area, ensuring reliable detection and reducing false alarms. The detectors are suitable for surface and flush mounting and are designed to prevent false alarms.

The AVENAR detector 4000 series offers various single-sensor and multi-sensor detectors:

IdentifierDescriptionCategoryStandard
FAP-425-OOptical smoke detector, automatic address setting onlySingle-sensorEN 54-7
FAP-425-O-ROptical smoke detector, automatic and manual address settingSingle-sensorEN 54-7
FAP-425-OTCombined optical and thermal smoke detector, automatic address setting onlyMulti-sensorEN 54-5, EN 54-7
FAP-425-OT-RCombined optical and thermal smoke detector, automatic and manual address settingMulti-sensorEN 54-5, EN 54-7
FAP-425-DO-RDual optical smoke detector, automatic and manual address settingDual-sensorEN 54-7
FAP-425-DOT-RCombined dual optical and thermal smoke detector, automatic and manual address settingMulti-sensorEN 54-5, EN 54-7, EN 54-29
FAP-425-DOTC-RCombined dual optical, thermal, and chemical smoke detector, automatic and manual address settingMulti-sensorEN 54-5, EN 54-7, EN 54-29
FAP-425-DOTCO-RCombined dual optical, thermal, and chemical (CO gas) detector, automatic and manual address settingMulti-sensorEN 54-5, EN 54-7, EN 54-29, EN 54-26, EN 54-30, EN 54-31
FAH-425-T-RThermal detector, automatic and manual address settingSingle-sensorEN 54-5

System Overview

The AVENAR detector 4000 can integrate up to three sensor types: Optical (O), Dual Optical (DO), Thermal (T), and Chemical (C for CO gas). Rotary switches (R) allow for automatic or manual address setting on certain models. Programming is done via the FSP-5000-RPS software. The detectors continuously monitor and adjust their sensitivity to adapt to the environment. They are compatible with LSN advanced technology fire alarm control panels (FACPs).

Sensor Technologies

Features

Accessories

Various accessories are available for the AVENAR detector 4000 series, including:

Installation and Configuration Notes

When planning for multi-sensor fire detectors, follow the guidelines for optical detectors (refer to DIN VDE 0833 Part 2 and VDS 2095). Key parameters include:

For planning where optical sensors may need to be temporarily deactivated, follow guidelines for heat detectors (refer to DIN VDE 0833 Part 2 and VDS 2095):

Important Notes:

Programming

Programming is performed using the FSP-5000-RPS software. The detector is programmed based on its operating area. Different operating modes can be selected, allowing individual sensors to be deactivated. Sensitivity levels for optical sensors can be adjusted to three levels for optimal performance.

Programming Examples

Connections

Detector bases are mounted using two screws, approximately 55 mm apart. Ensure a flat and dry mounting surface. Cable entry points are available for surface and flush mounting. Locking clips prevent unauthorized removal of the detector head.

MS 400/MS 400 B Connection

Standard detector bases with seven screw terminals.

FAA-MSR 420 Connection

Base with a changeover contact relay. Maximum contact load: 62.5 VA (125 V AC, 0.5 A) or 30 W (30 V DC, 1 A).

Detector Head Mounting

The detector head is placed onto the base and turned clockwise until it locks. Locking clips secure the head.

Detector Removal

For detectors with unlocked heads, turn counter-clockwise and lift off the base. For locked heads, insert a screwdriver into the release opening (Y) to unlock before turning.

Address Setting

Models with automatic and manual address setting have three rotary switches. These switches are used to set the address and operating mode (e.g., advanced LSN mode, classic LSN mode). Automatic address assignment by the fire panel requires all detectors to have address '0 0 0'. For classic LSN panels, the address should be 'CL 0 0'. Manual address setting involves using the rotary switches for units, tens, and hundreds digits. Addresses up to 254 are permitted.

Remote Indicator Mounting

Instructions are provided for mounting the FAA-420-RI-ROW and FAA-420-RI-DIN remote indicators.

Ordering Information

Detailed tables list the various detector types, their descriptions, and product codes. This includes:

Maintenance and Service

Maintenance and inspection work should be performed by trained personnel according to DIN VDE 0833 regulations. Bosch recommends an annual functional and visual inspection. Remote maintenance is permitted for certain procedures. The chemical sensor in FAP-425-DOTC-R has a maximum service life of 6 years, requiring replacement. The chemical sensor in FAP-425-DOTCO-R has a 10-year service life. Detectors should be replaced after this period. Optical detectors may require more frequent cleaning and replacement in dusty environments.

Detector Type Coding

Color rings around the central display help identify detector types.

Test Instructions

Specific test procedures are outlined for optical, thermal, and chemical sensors. Tests can be performed using test sprays or gas canisters. The detectors can be tested in revision mode or outside of it, depending on the configuration.

Diagnostic Data

Diagnostic data includes detector status (normal, fault, alarm), optical system values (indicating contamination level), temperature readings, CO analog values, operating time, and error codes.

Warranty

Defective detectors will be replaced free of charge under warranty.

Repair

In case of a fault, the entire detector should be replaced.

Disposal Information

Electrical and electronic devices must be disposed of according to regulations (e.g., WEEE in Europe). Packaging film for FAP-425-DOTC-R and FAP-425-DOTCO-R is made of tear-resistant PE-ALU laminate and can be disposed of with normal waste.

Technical Data

Detailed tables provide technical specifications for each detector model, including:

Note: FAP-425-DOTCO-R detectors require replacement after 10 years due to the CO sensor's limited lifespan.

PDF preview unavailable. Download the PDF instead.

FAP 425 Operation Manual trTR 18228443019 ST4 PDF Engine (Build 11.0.3.0) SCHEMA ST4

Related Documents

PreviewBosch AVENAR Detector 4000 User Manual
Comprehensive user manual for the Bosch AVENAR Detector 4000 series (FAP-425 / FAH-425). This guide covers product description, system overview, sensor technology, features, compatibility, accessories, installation, programming, maintenance, and technical data.
PreviewAVENAR detector 4000 Bedieningshandleiding
Gedetailleerde bedieningshandleiding voor de AVENAR detector 4000 serie, inclusief productbeschrijving, systeemoverzicht, installatie-instructies, programmering, accessoires en technische specificaties.
PreviewManual do Utilizador AVENAR Detector 4000
Este manual fornece informações detalhadas sobre o AVENAR Detector 4000 da Bosch, incluindo descrição do produto, vista geral do sistema, funções dos sensores, características, compatibilidade, acessórios, instalação, programação, manutenção e dados técnicos. O detector oferece deteção avançada de incêndio com múltiplos sensores.
PreviewBosch AVENAR Detector 4000 User Manual
This manual provides comprehensive information on the Bosch AVENAR Detector 4000, covering its product description, system overview, programming, connection, accessories, and maintenance. It details various detector types, their functionalities, installation procedures, and technical specifications.
PreviewBosch FAP-425 Automatic Fire Detectors LSN Improved Version
This document provides detailed technical specifications, intended use, installation, operation, and contact information for the Bosch FAP-425 Automatic Fire Detectors LSN Improved Version. It covers various models and their features, ensuring proper understanding and application of these fire detection devices.
PreviewBosch AVENAR Detector 4000 Bedienungsanleitung
Die Bedienungsanleitung für den Bosch AVENAR Detector 4000 (FAP-425/FAH-425 Serie) bietet detaillierte Informationen zur Produktbeschreibung, Systemübersicht, Programmierung, Anschaltung, Bestellübersicht sowie Wartung und Service. Erfahren Sie mehr über die verschiedenen Sensortypen, Leistungsmerkmale und Zubehörteile.
PreviewBosch Automatic Fire Detectors LSN Improved Series: Installation and Operation Manual
This manual provides detailed information on the installation, configuration, operation, and maintenance of Bosch Automatic Fire Detectors from the LSN Improved series, including models FAP-O 520, FAP-O 520-P, FAP-OC 520, and FAP-OC 520-P. It covers product features, technical specifications, and troubleshooting.
PreviewBosch Fire Detectors LSN Improved Version Installation and Operation Manual
This document provides comprehensive instructions for the installation, programming, maintenance, and technical specifications of Bosch automatic fire detectors, LSN improved version, including models FAP-O 520, FAP-O 520-P, FAP-OC 520, and FAP-OC 520-P.