Allmatic B.RO22 LED Rolling Code Receiver

Manufacturer: Allmatic s.r.l.

Address: Via dell’Artigiano Nº 1, 32020 Lentiai (BL), ITALY

Contact: T. (+39) (0)437 75 11 75, F. (+39) (0)437 75 10 65

Website: www.allmatic.com

In compliance with Directive 1999/05/CE

Product Description

The B.RO22 LED is a 2-channel rolling code receiver designed for managing two clean contact relays via variable code radio commands. It supports independent learning for each relay.

Installation

Connect the receiver according to the provided diagram. Ensure the correct voltage selection jumper (Jumper C) is set for either 12 Vac/dc (closed) or 24 Vac/dc (open). Connect the power supply to terminals 5 and 6. If using multiple receivers, space them 3-4 meters apart to prevent interference. For optimal performance, connect a good quality ground to terminal 7 (screw terminal version) or terminal 9 (plug-in connector version). Position the antenna away from obstacles and metal structures, or above them if grounded. Connect the antenna signal to terminal 8 (screw terminal) or terminal 10 (plug-in connector) and the shielding to terminal 7 (screw terminal) or terminal 9 (plug-in connector). The antenna is crucial for maximum range; without it, the range is significantly reduced. If the antenna cable is too short, replace it with a longer one of the same impedance (50 ohm, e.g., RG58), ensuring the total cable length does not exceed 10 meters. If wall-mounting, use appropriate screws and anchors to support a downward force of 50N.

Important Note: If the receiver is powered by AC voltage (Vac), use an isolation transformer (SELV) with limited power or short-circuit protection.

Transmitter Management

How to Memorize a Transmitter Code

  1. Power the receiver on terminals 5 and 6, ensuring Jumper C is correctly set.
  2. Press the learning button briefly. LED1 will indicate the learning phase is active. LED2 or LED3 will indicate the selected channel for learning.
  3. Press the learning button once to select Channel 1 (LED2 illuminates). Press it twice to select Channel 2 (LED3 illuminates).
  4. Transmit the radio command from the transmitter you wish to memorize. The corresponding channel LED will flash to confirm successful memorization, and the learning mode will reactivate.
  5. The learning mode exits automatically after 10 seconds of inactivity or by pressing the learning button again. All LEDs will turn off.

Attention: If LED 2/3 does not blink during memorization, the code was not stored. Verify the transmitter frequency matches the receiver, it's a rolling code type, or the memory is full (maximum transmitters learned).

How to Cancel a Single Transmitter

  1. Approach the receiver.
  2. Press and hold the hidden button on the transmitter to be cancelled.
  3. While holding the hidden button, press the first button on the transmitter.
  4. All receiver LEDs will blink. When they turn off, the transmitter has been cancelled from all receivers within range.

How to Cancel All Transmitters and Settings (Reset)

  1. Disconnect power from the receiver.
  2. Press and hold the learning button, then reconnect the power. LED1 will illuminate after approximately 5 seconds.
  3. Release the learning button.
  4. Wait for LED1 to blink 2 or 3 times. When it turns off, all codes are cancelled.

Function Selection

The receiver offers three output modes for the relays:

Setting Functions: Use Jumpers A and B to select the mode for each channel/relay:

Timed Function Mode Settings

When MODE 2 is selected (Jumper open), the timing type (immediate or timed) can be configured:

  1. Activate the configuration menu by pressing and holding the learning button until LED2 starts blinking simultaneously with LED1. The blinking pattern of the channel LED indicates the current selection: fast blinking for immediate, slow blinking for timed.
  2. To move to the next channel, press and hold the learning button for at least 3 seconds.
  3. With the desired channel selected, change the timing type by pressing and releasing the learning button. The slow blinking of the corresponding relay LED indicates the timed mode.
  4. To program the timed duration, transmit a memorized radio command associated with the selected channel. The channel LED will begin blinking every second, indicating the programmed time duration.
  5. Once the desired time has elapsed, transmit another radio command to finalize the programming. The maximum programmable time is 18 hours. The programmed time is stored until the next programming or reset. If both relays are set to timed mode, a single operation can program the same activation time for both by pressing the learning button for 3 seconds until LED2 and LED3 are lit.
  6. The menu exits via timeout after 10 seconds of inactivity or by pressing the learning button for 3 seconds, which turns off all LEDs.

Technical Features

FeatureSpecification
CodificationRolling Code
Power Supply12 Vac/dc (Jumper C closed) or 24 Vac/dc (Jumper C open)
Consumption50mA
Channels2
AntennaTuned at 433.92 MHz
Frequency433.92 MHz
Reach80 - 250 meters
Relay Contact1A at 30 Vdc / 0.5A at 42.4 Vac
Operating Temperature-10 to 55 °C
Memorizable Transmitters1000 (with memory) / 30 (without memory)

Solutions

Solution A: Screw Terminal Board

Solution B: Plug-in Connector

Jumper Settings

Jumper A: Controls Channel/Relay 1 function.

Jumper B: Controls Channel/Relay 2 function.

Jumper C: Selects power supply voltage (closed for 12 Vac/dc, open for 24 Vac/dc).

LED Indicators

Warnings and Suggestions

Warranty Terms

The manufacturer's warranty is valid according to law from the date stamped on the product. It covers free repair or replacement of parts recognized as defective due to material or manufacturing faults. The warranty does not cover damage or defects caused by external agents, lack of maintenance, overload, natural wear, incorrect product selection, or improper installation. Tampered products are not covered. Data provided is for guidance only. The manufacturer is not liable for range reductions or malfunctions due to environmental interference. The manufacturer's liability for damages caused by defective products is limited by Italian law.

Models: B.RO22 LED Led Rolling Code Receiver, B.RO22, LED Led Rolling Code Receiver, Rolling Code Receiver, Code Receiver, Receiver

File Info : application/pdf, 2 Pages, 129.51KB

PDF preview unavailable. Download the PDF instead.

ALLMATIC-BRO22LED

References

GPL Ghostscript 9.55.0

Related Documents

PreviewAllmatic ASR2 433/AP LED AM 2-Channel Receiver - User Manual and Technical Specifications
This document provides detailed instructions for the Allmatic ASR2 433/AP LED AM, a 2-channel fixed code receiver. It covers installation, programming, function selection (immediate, step-by-step, timed), troubleshooting, and warranty information. Technical specifications and connection diagrams are included.
PreviewProxima M Control Unit for Rolling Shutters - User Manual
Instructions and technical specifications for the Proxima M control unit, designed for single-motor rolling shutters and blinds. Covers installation, configuration, transmitter learning, and advanced settings.
PreviewCentrale PROXIMA S: Motor Control Unit for Rolling Shutters
Instructions and technical specifications for the PROXIMA S control unit, designed for single-motor rolling shutters. Covers installation, transmitter programming, and advanced configuration.
PreviewAllmatic TECH3 POWER and B.RO Series Remote Transmitters User Guide
User guide for Allmatic TECH3 POWER and B.RO series remote transmitters, covering product descriptions, technical specifications, and instructions for memorizing and cancelling transmitters.
PreviewAllmatic B.RO X40 DISPLAY Ricevitore Rolling Code a 4 Canali - Manuale Tecnico
Manuale tecnico completo per il ricevitore Allmatic B.RO X40 DISPLAY. Copre installazione, configurazione, apprendimento trasmettitori, gestione menu, modalità operative, specifiche tecniche e risoluzione problemi.
PreviewManuale Utente Telecomando Allmatic FOR4
Istruzioni e specifiche per il telecomando Allmatic FOR4 rolling code, inclusi programmazione e sostituzione batteria.
PreviewAllmatic ASR, AKR, RMAS, RMAK Programmable Digital Code Receivers
Technical documentation for Allmatic's ASR, AKR, RMAS, and RMAK series of programmable digital code radio receivers. Details features, installation, and warranty information.
PreviewAllmatic MICROCAP 16 Control Unit: Installation and Operation Manual
Comprehensive guide for installing, configuring, and operating the Allmatic MICROCAP 16 control unit for rolling shutters and blinds, including details on transmitter learning, sensor integration, and troubleshooting.