AAON ASM01686 Refrigerant System Module for VFD Compressors (RSMV)

Stay in control with customizable control solutions. AAON offers a wide range of control solutions to optimally regulate and monitor the operation of your HVAC systems.

PHYSICAL

Configurable Unit Controllers that Can Be Used for Multiple Applications

The ASM01686 Refrigerant System Module for VFD Compressors (RSMV) monitors and controls one refrigeration circuit of the HVAC unit. The RSMV connects to the VCCX2, VCCX, and VCCX-IP Controllers.

The RSMV provides four analog inputs, three binary inputs, three relays, and four analog outputs. Up to four RSMV's can be connected, depending on the size of the system. The module is designed for R410-A refrigerant.

Allows Connection for Communicating Sensors

There are two E-BUS expansion ports which allow the connection of communicating sensors and E-BUS modules.

Electrical and Environmental

ParameterSpecification
Operating Power18-30 VAC
Power Consumption18 VA Maximum
Operating Temperature-22°F to 158°F
Operating Humidity0-95% RH Non-Condensing
Inputs4 Analog Inputs, 2 Binary Inputs (Pre-assigned)
Outputs3 Relay Outputs, 2 Analog Outputs (Pre-assigned)

Diagrams and Dimensions

Top View of RSMV Module: The diagram shows the layout of the RSMV module with various connection terminals labeled. Key components and their approximate locations are indicated. Terminals include power (+5V, GND, +24 VAC), communication (RSMU, MODBUS), inputs (TEMP1, TEMP2, TEMP3, BIN1, BIN2), outputs (RLY1, RLY2, RLY3, AOUT1, AOUT2), and E-BUS expansion ports.

Side View and Dimensions: The diagram illustrates the physical dimensions of the RSMV module in inches. The overall width is approximately 5.73 inches, and the height is approximately 5.00 inches. The depth is approximately 1.49 inches. Mounting holes are indicated, with dimensions for placement.

Terminal Designations: Detailed labeling of various terminals on the module, including power inputs, sensor inputs (temperature, pressure), relay outputs, analog outputs, binary inputs, and E-BUS communication ports. Specific terminals are designated for sensors like suction pressure, head pressure, and coil temperature.

INSTALLATION

Mounting

The RSMV module is housed in a plastic enclosure. It is designed to be mounted using the three mounting holes in the enclosure base and the included mounting screws (#8 x 1" sheet metal screws).

The RSMV needs to be installed in an environment which can maintain a temperature range of -22°F to 158°F not to exceed 95% RH levels (Non-Condensing). It is important to mount the device in a location that is free from extreme high or low temperatures, moisture, dust, and dirt. Be careful not to damage the electronic components when mounting the module.

Scan the code for additional product information [QR Code Placeholder] ?

Contact AAON Support for Technical Assistance

www.aaon.com/contact

PDF preview unavailable. Download the PDF instead.

ASM01686-RSMV-INSTL-A Adobe PDF Library 17.0 Adobe InDesign 20.4 (Windows)

Related Documents

PreviewAAON VCC-X EM1 Expansion Module ASM01691 - Technical Overview
Detailed technical specifications and installation guide for the AAON VCC-X EM1 Expansion Module (ASM01691), enhancing HVAC system control with additional inputs and outputs.
PreviewAAON RSMVQ ASM02293 Configurable Unit Controller - Technical Specifications and Installation
Detailed information on the AAON RSMVQ ASM02293 configurable unit controller, including physical and electrical specifications, environmental operating conditions, input/output capabilities, and mounting instructions for HVAC systems.
PreviewAAON RSMV-HP ASM01693 Controller Installation and Specifications
This document provides installation and electrical/environmental specifications for the AAON RSMV-HP ASM01693 configurable unit controller, designed for HVAC systems.
PreviewAAON E-BUS 12 Relay Expansion Module ASM01873 - Technical Specifications and Installation
Detailed technical specifications and installation guide for the AAON E-BUS 12 Relay Expansion Module (ASM01873), designed to increase relay outputs for AAON controllers.
PreviewAAON ASM01870 BACnet General Controller: Installation and Specifications
This document provides detailed information on the AAON ASM01870 BACnet General Controller, including its physical and electrical specifications, mounting instructions, and capabilities for HVAC system control.
PreviewAAON MHGRV-X Controller ASM01670 - Technical Specifications and Installation
Detailed information on the AAON MHGRV-X Controller (ASM01670), including its physical and electrical specifications, installation guidelines, and modular connectivity features for HVAC systems.
PreviewAAON Reheat Expansion Module ASM01687 Installation and Specifications
Detailed information on the AAON Reheat Expansion Module ASM01687, including its physical and electrical specifications, features, and installation guidelines. This module is designed to control reheat valves in AAON HVAC systems.
PreviewAAON MODGAS-X Controller ASM01668: Technical Specifications and Installation
Detailed information on the AAON MODGAS-X Controller ASM01668, including its physical and electrical specifications, environmental operating conditions, and mounting instructions for HVAC systems.