Katalozi – Steelsoft
ITALIAN COMPANY SINCE 1956 INTEGRATED SYSTEMS AND AIR CONDITIONING Catalogue 2024 EN Your Home Comfort since 1956 Olimpia Splendid is an Italian company that - for almost 70 years - has been designing, producing and marketing technologies for conditioning, heating and treating the air in the home. Ensuring the best home comfort, at all times of the year and for all our customers around the world, is our goal. Taking care of the climate in the home, while respecting that of the Planet is how we have chosen to achieve this. For this reason, we create innovative products with a high aesthetic finish, efficient and with reduced environmental impact: solutions for more sustainable comfort. Our Home is the Planet Olimpia Splendid's commitment to sustainability is built around 5 key points, which are inspired by the objectives defined by the UN in the 2030 Agenda for Sustainable Development: a program of actions for people, the planet and prosperity. From 2021, Olimpia Splendid's results are monitored and published through the annual Sustainability Report. Innovative and inclusive solutions Our strategy for sustainable economic growth is based on innovation and diversification. There are 12 technological patents currently active, created to overcome the limits of traditional solutions and to make climate comfort a right within everyone's reach. Carbon neutral processes To efficiently use industrial resources, we have set ourselves the goal of reducing our direct and indirect greenhouse gas emissions by 50% by 2030 and of achieving complete climate neutrality by 2040. Efficient technologies Researching and developing new heat pump comfort systems is our direct contribution to creating sustainable cities and communities, where domestic consumption is decarbonised and the available electricity is used wisely. Products that are durable and can be regenerated For an eco-compatible waste management, we select components and materials based on their recyclability and repairability, we guarantee spare parts for a minimum of 15 years and we encourage the recovery and disposal of end-of-life products through the most virtuous consortia. Shared responsibility The fight against climate change must be objective and a shared responsibility. This is why we are personally committed to effectively informing our consumers and to promoting sustainable behaviour in the use of our products. 2 Catalogue 2024 | January edition Made in Italy around the world Every Olimpia Splendid product is born in the Brescia headquarters, where the R&D centre designs and develops solutions capable of standing out for their innovation, aesthetic finish and sustainability, following the LCA (Life Cycle Assessment) principles. The core technologies are created in our Italian production pavilion, 100% powered by renewable electricity and designed as a highly productive Smart Factory. From Italy, the Olimpia Splendid brand comfort then reaches over 45 countries around the world, through 5 direct commercial branches and a widespread network of distributors. FRANCE Parigi Commercial subsidiary USA New York Commercial subsidiary SPAIN Madrid Commercial subsidiary CHINA Shanghai Trading subsidiary Cellatica-BS Headquarters and production site ITALY Gualtieri-RE Logistic hub AUSTRALIA Melbourne Commercial subsidiary 3 ONLINE SERVICE Download Area All of the documentation necessary for installation and operation of our machines can be found in the download section of our website www.olimpiasplendid.com Private Documentation Do you need performance data and specifications related to heat pumps and plant terminals? Access the reserved area for all necessary information. Products Documentation Should you need additional information regarding our products, consult the "Products Documentation" section. Here, you will find energy labels, templates and installation manuals and product catalogues. 4 TABLE OF CONTENTS 13 SiOS CONTROL Building Management System 14 SiOS CONTROL 19 SHERPA Air-water heat pumps, split and single-piece, and heat pump water heaters 26 SHERPA AQUADUE 32 SHERPA 40 KIT SHERPA FLEX BOX 42 SHERPA COLD 46 SHERPA MONOBLOC 50 SHERPA SHW 52 ACCESSORIES 58 SYSTEM DIAGRAMS 63 Bi2 Hydronic system terminal units for annual cycle comfort 70 Bi2 AIR 74 Bi2 WALL 78 Bi2 SMART 80 Bi2 NAKED 88 Ci2 WALL 90 ACCESSORIES 97 SITALI Decentralised and ducted heat recovery ventilation units 102 SITALI SF 150 S1 103 SITALI SFE 100 104 SITALI CX 120 106 SITALI CX 180 108 SITALI CX 280 110 SITALI CX 400 112 SITALI CX 550 114 ACCESSORIES Catalogue 2024 | January edition 123 UNICO Air conditioners and air-to-air heat pumps without outdoor unit 132 UNICO EVO 134 UNICO AIR 136 UNICO EDGE 142 UNICO PRO 144 UNICO TOWER 146 UNICO TWIN 148 UNICO EASY 150 UNICO R 152 ACCESSORIES 157 NEXYA Monosplit and multisplit air conditioners 162 NEXYA ENERGY E 164 NEXYA S4 E 166 NEXYA COMMERCIAL DUCT 168 NEXYA COMMERCIAL CASSETTE 170 NEXYA COMMERCIAL CEILING 172 NEXYA MULTISPLIT 179 DOLCECLIMA Portable air conditioners 182 DOLCECLIMA ARIA 8 184 DOLCECLIMA SILENT S1 10 186 DOLCECLIMA SILENT 12 A+ WIFI 188 DOLCECLIMA AIR PRO 14 HP WIFI 5 INTEGRATED SYSTEMS Olimpia Splendid integrated systems The next generation plant for low-consumption buildings and energy requalification A yearlong cycle of climate control The Integrated Systems Olimpia Splendid deliver heating, cooling, dehumidification, air treatment and the production of domestic hot water. Everything necessary for home comfort, 365 days a year, all included in a single plant: simple, efficient, integrated. The plant solution of Olimpia Splendid simplifies the design and installation operations, as well as the use and maintenance interventions of all the products for home comfort. The generators have high energy efficiency and the fan coil units have high performance, for complete indoor comfort that also has an eye on consumption. Moreover, thanks to the building management system, SiOS Control, the management is total and integrated. Plant operation LOW-TEMPERATURE RADIATION VENTILATED HEATING COOLING DEHUMIDIFICATION AIR FILTERING DHW UP TO 75°C AIR EXCHANGE MOULD PREVENTION REMOTE PLANT SUPERVISION 8 Catalogue 2024 | January edition Heat pumps, for maximum efficiency The evolution of buildings and their envelopes has also determined a change in the new plants. Heat pumps are increasingly becoming the protagonists of the plant as the sole generator, able to optimise energy consumption and promote the use of renewable energy sources. Olimpia Splendid offers a range of solutions that are specific for every climate, distinguished by their extremely high energy efficiency (up to A+++) and maximum reliability, thanks also to a patented technology for the simultaneous production of comfort and DHW up to 75°C. Radiant fan coil units as new plant terminals The radiant fan coil units offer year-round comfort (heating and cooling) that can be compared to that of floor heating, with always lower installation costs and a more economical management of the plant in the warmer climate zones. First company to introduce slim and ultraslim radiant fan coil units on the market, specifically for residential plants, Olimpia Splendid still today stands out in the segment for a range of solutions entirely designed and manufactured in Italy and with a patented radiant technology, which allows the static operation of the machine during heating, for complete absence of noise. HRV for improved indoor quality of air With the evolution of building envelopes, air exchange and air treatment have become necessary for the correct maintenance of the quality of air of indoor settings. Should the simple opening of windows not be possible or sufficient, the solutions of Heat Recovery Ventilation offer a valid support. Olimpia Splendid offers decentralised solutions, for simplified installation, or centralised as part of a renovation or new build. All equipped with brushless EC motors, with reduced energy consumption, Olimpia Splendid's HRV units are fitted with heat recovery units to transfer energy from the air extracted from indoor environments to the fresh air supplied from outside, limiting the activation of the air-conditioning system and improving the building's energy performance. Catalogue 2024 | January edition BMS for the centralised management of the plant The centralised management of the plant allows optimisation and greater efficiency according to our habits and ways of living in our buildings. SiOS Control is the Building Management System by Olimpia Splendid that allows a simple, intuitive and customisable management of the plant. It is possible to control the individual components: heat pump, fan coil units, floor heating, towel warmers and HRV. The management can take place either on site or remotely, through the web platform (Cloud) or mobile application 9 SHERPA AQUADUE Multi-purpose air water heat pumps SHERPA Traditional air water heat pumps SHERPA COLD Air water heat pumps for cold climate SHERPA MONOBLOC Monobloc air water heat pumps SiO Olimpia integrate SHERPA SHW Water heater in heat pump SiOS CONTROL Central system management, locally or remotely 10 SITALI Decentralised and centralised HRV Bi2 WALL High wall fan coil units OS Splendid ed systems Bi2 AIR Fan coils units with integral design Ci2 WALL High wall fan coil units Bi2 SMART Total flat fan coil units Bi2 NAKED Recessed fan coil units 11 SiOS CONTROL Building Management System SiOS CONTROL Central system management, locally or remotely Complete and intuitive SiOS Control is the BMS (Building Management System) by Olimpia Splendid that allows simple management of the plant for heating, cooling, air treatment and domestic hot water. Through an intuitive graphical interface, that can be customised based on the characteristics of each environment, you can control individual system components: heat pumps, fan coil units, floor heating, towel warmers and HRV, from both the Olimpia Splendid range and other manufacturers*. For a truly complete control. Furthermore, with SiOS Control, you can even manage things remotely, through the web (Cloud) platform or a mobile application. Complete, intuitive and smart. What can it manage? Sherpa range of heat pumps or third-party generators* Fan coil units range and floor heating Bi2 Sitali HRV range** or third-party HRV* Towel warmers** How does it work? *Requires prior check for compatibility ** Opto-coupler card + relay with power supply required, check details on the technical manual for specific characteristics. 14 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS FEATURES Type of control DIRECT ZONE: - up to 30 Bi2 fan coil units and relative controls (divided up to a maximum of 10 independent environments); - 1 heat pump from among Sherpa S2/S3, Sherpa Aquadue S2/S3, Sherpa Tower S2/S3, Sherpa Aquadue Tower S2/S3 and Sherpa Monobloc S1/S2 E (or other third-party generators)*; - up to 4 towel warmers, with relative thermostats**; - 1 direct zone circulator output; - 1 outdoor air temperature probe. HVR: - 1 group output for Sitali** (or other third-party HVR)*. Simplified installation Easy installation through a first guided configuration to be able to customise SiOS Control both to the characteristics of the plant and to those of the building in which it will be installed. Customised environments Possibility of creating customised environments in order to reproduce the layout of each individual building. Possibility of creating up to 10 total environments with fan coil units and radiant floor. Possibility of naming the environments and assigning dedicated icons to them. Comfort management for every season SiOS Control can manage cooling, heating, domestic hot water and air treatment. The intuitive graphic interface with icons changes colour based on the functions of the plant and whether or not the various environments are active or shut off. Timer with scenarios SiOS Control has weekly timers. It manages up to 4 timers and each individual timer can be set with 6 daily time ranges. For each time range there are 5 scenarios available. Economy, Comfort, Night are the pre-set scenarios, while the 2 Individual scenarios can be set directly by the user. Heat pump temperature settings With SiOS Control, the user can change the water set points of the heat pump and activate any climatic curves for summer and winter operation. HRV UNICO MONO AND MULTISPLIT PORTABLES * Requires prior check for compatibility ** Opto-coupler card + relay with power supply required, check details on the technical manual for specific characteristics. NOTE 1: The application for Tablets and Smartphones allows simplified management of the functions. Catalogue 2024 | January edition 15 MANAGEMENT Only local management Connecting the B0858 central control unit to an Access Point by means of a network cable, it is possible to manage SiOS Control remotely in the local Wi-Fi, through PCs, Tablets, Smartphones and a common internet browser. Remote management (also local) Connecting the B0858 central control unit to an internet router by means of a network cable, it is possible to manage SiOS Control remotely through the cloud, through PCs, Tablets, Smartphones and a common internet browser. In addition, for a simplified remote management, the SiOS Control App is available that assumes the main functions. The remote use requires a two-year subscription. Remote assistance The Olimpia Splendid Service Centre, through the Cloud, will be able to carry out assistance to the plant and its machines even remotely, for a faster and more efficient service in case of plant problems or alarms. COMPONENTS CODE B0858 DESCRIPTION Control centraliser The centraliser is the component necessary for all SiOS Control installations. It features a touch display, an output for the network cable and Modbus RTU 0-10V outputs, as well as relays for the various system components. B0860 B0861 B0863 B0623 Wall ambient T-H probe kit Wall thermostat necessary to control installations and/or environments with towel warmers. Shows the temperature and relative humidity. Built-in ambient T-H probe kit Built-in thermostat necessary to control installations and/or environments with towel warmers. Shows the temperature and relative humidity. RTU-ASCII fan coil signal converter kit RTU-ASCII converter required for those installations where there are direct water zones (Recommended to use one over 500 meters of communication line). Outdoor air temperature probe kit Shielded probe to measure the outdoor air temperature The transformers required to power the individual devices, as indicated in the manuals and installation diagrams of SiOS Control, are not included in the Olimpia Splendid supply. 16 Catalogue 2024 | January edition BMS SYSTEM DIAGRAMS Example of a SiOS control diagram with management of: - Sherpa Aquadue Tower heat pump - Bi2 Air and Bi2 Wall fan coil units - DHW and towel warmer - Sitali SF150 S1 and Sitali SFE100 S1 HEAT PUMPS FAN COIL UNITS HRV UNICO MONO AND MULTISPLIT Note: the diagram only has the purpose of illustrating the system, for all the characteristics and connections, refer to the relative installation manuals Legend: B0858 CENTRAL SiOS CONTROL UNIT B0860 WALL MOUNTED ROOM PROBE KIT T-H B0861 BUILT-IN ROOM PROBE KIT T-H B0863 RTU-ASCII FANCOILS SIGNAL CONVERTER KIT B0623 OUTDOOR AIR TEMPERATURE PROBE KIT Catalogue 2024 | January edition 17 PORTABLES SHERPA Air-water heat pumps, split and single-piece, and heat pump water heaters Specific solutions for each European climate To achieve maximum efficiency and reliability in every project Warm climatic zones, Average and Cold The relevant European regulations identify, within the reference territory, 3 different climatic zones, in which the project temperatures relating to indoor comfort systems are profoundly different. A comparative study commissioned by Olimpia Splendid has shown how each of these climates determines a different distribution of the thermal and cooling load inside buildings and a specific behaviour of the heat pumps. Specific configurations to maximise efficiency and comfort To optimize the efficiency and output power of the heat pumps according to the external temperature, Olimpia Splendid offers the possibility to choose between different types of heat pumps, specially designed for the reference European climates. 20 Catalogue 2024 | January edition Aquadue patented technology Innovation that ensures simultaneously comfort and DHW Catalogue 2024 | January edition Double refrigerantion circuit In Olimpia Splendid heat pumps equipped with Aquadue technology, the two interconnected cooler cycles make it possible to make the heating/cooling independent from the DHW production, allowing it to operate in parallel. A feature that avoids interruptions in the provision of home comfort. Domestic Hot Water up to 75°C The double refrigerantion circuit present in the Aquadue models also allows the production of DHW at a high temperature (up to 75°C), regardless of the external climatic conditions. Thus it is possible to reduce the volume of the storage tank up to 30% and to avoid highly energy-intensive anti-legionella cycles (normally carried out with the use of electric heating elements). Coverage of the renewable quantity for the production of DHW Thanks to the efficient management of heat, Aquadue technology facilitates the achievement, in buildings with a high energy class, of the coverage quantities from renewable energy without the installation of additional devices. 21 Split air-water heat pumps Production of comfort and DHW SINGLE-PHASE 4 6 8 10 SHERPA AQUADUE Multi-purpose Download Technical data sheet for the entire S2 range Outdoor units S2 SUSPENDED VERSION TOWER VERSION UE Sherpa S2 E 4 (02001) UE Sherpa S2 E 6 (02002) UI Sherpa Aquadue S2 E Small (02042) UI Sherpa Aquadue Tower S2 E Small (02044) SHERPA Traditional Download Technical data sheet for the entire S2 range S2 Outdoor units SUSPENDED VERSION TOWER VERSION UE Sherpa S2 E 4 (02001) UE Sherpa S2 E 6 (02002) UI Sherpa S2 E Small (02040) UI Sherpa Tower S2 E Small (02046) SHERPA AQUADUE Multi-purpose S3 Outdoor units SUSPENDED VERSION TOWER VERSION UE Sherpa S3 E 4 (02284) UE Sherpa S3 E 6 (02285) UE Sherpa S3 E 8 (02286) UI Sherpa Aquadue S3 E Small (02296) UI Sherpa Aquadue Tower S3 E Small (02298) UE Sherpa S3 E 10 (02287) SHERPA Traditional S3 Outdoor units SUSPENDED VERSION TOWER VERSION UE Sherpa S3 E 4 (02284) UE Sherpa S3 E 6 (02285) UE Sherpa S3 E 8 (02286) UI Sherpa S3 E Small (02294) UI Sherpa Tower S3 E Small (02300) UE Sherpa S3 E 10 (02287) SHERPA COLD For cold climates Outdoor units SUSPENDED VERSION UE Sherpa Cold 10 (02269) UI Sherpa Cold (02276) Energy efficiency classes in heating, water at 35°C (average climate). For Sherpa SHW classes according to Regulation EU 812/2013. 22 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV THREE-PHASE 12 14 15 16 10T 12T 14T 15T 16T 18T UE Sherpa S2 UE Sherpa S2 12 (02005) 14 (02006) UE Sherpa S2 16 (02007) UE Sherpa S2 UE Sherpa S2 12T (02008) 14T (02009) UI Sherpa Aquadue S2 Big (02043) UI Sherpa Aquadue Tower S2 Big (02045) UE Sherpa S2 16T (02010) UE Sherpa S2 UE Sherpa S2 12 (02005) 14 (02006) UE Sherpa S2 16 (02007) UE Sherpa S2 UE Sherpa S2 12T (02008) 14T (02009) UI Sherpa S2 Big (02041) UI Sherpa Tower S2 Big (02047) UE Sherpa S2 16T (02010) UE Sherpa S3 UE Sherpa S3 E 12 (02288) E 14 (02289) UE Sherpa S3 E 16 (02290) UE Sherpa S3 UE Sherpa S3 E 12T (02291) E 14T (02292) UI Sherpa Aquadue S3 E Big (02297) UI Sherpa Aquadue Tower S3 E Big (02299) UE Sherpa S3 E 16T (02293) UE Sherpa S3 UE Sherpa S3 E 12 (02288) E 14 (02289) UE Sherpa S3 E 16 (02290) UE Sherpa S3 UE Sherpa S3 E 12T (02291) E 14T (02292) UI Sherpa S3 E Big (02295) UI Sherpa Tower S3 E Big (02301) UE Sherpa S3 E 16T (02293) UE Sherpa Cold 15 (02273) UI Sherpa Cold (02277) UE Sherpa Cold 15T (02274) UI Sherpa Cold (02277) UE Sherpa Cold 18T (02275) UI Sherpa Cold (02278) UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 23 Monobloc air-water heat pumps and heat pump water heaters Production of comfort and DHW SINGLE-PHASE 4 6 8 10 SHERPA MONOBLOC Monobloc Outdoor units Sherpa Monobloc S1 E 8 (02022) Download Technical data sheet for the entire S1 range SHERPA MONOBLOC Monobloc S2 Outdoor units Sherpa Monobloc Sherpa Monobloc Sherpa Monobloc S2 E 6 (02303) S2 E 8 (02304) S2 E 10 (02305) Production of only DHW SHERPA SHW Water heater in heat pump S2 Outdoor units 200 Sherpa SHW S2 200 (02385) 260 Sherpa SHW S2 260S (02386) Energy efficiency classes in heating, water at 35°C (average climate). For Sherpa SHW classes according to Regulation EU 812/2013. 24 BMS HEAT PUMPS THREE-PHASE 12 14 15 16 10T 12T 14T 15T 16T 18T Sherpa Monobloc S1 E 12T (02024) Sherpa Monobloc Sherpa Monobloc S2 E 12 (02306) S2 E 14 (02307) Sherpa Monobloc S2 E 16 (02308) Sherpa Monobloc Sherpa Monobloc S2 E 12T (02309) S2 E 14T (02310) Sherpa Monobloc S2 E 16T (023011) FAN COIL UNITS HRV UNICO MONO AND MULTISPLIT PORTABLES 25 SHERPA AQUADUE S3 Multi-purpose split heat pumps, suspended and tower versions Compatible with: DHW AND COMFORT AT THE SAME TIME The two interconnected refrigerator cycles allow the decoupling of the heating/cooling from the DHW production, enabling them to operate in parallel, avoiding thus interruptions in the domestic comfort supply. DOMESTIC HOT WATER UP TO 75°C The storage of DHW at high temperature makes it possible to reduce the volume of the storage tank by up to 30%, and to avoid energy-intensive consumption of the anti-Legionnaire's disease cycles, since they are normally carried out by the use of electric heating elements. PHOTOVOLTAIC INTEGRATION Thanks to the appropriate contact, it is possible to activate an increase in the heating/DHW temperature and a decrease in the cooling temperature, thereby accumulating thermal energy in the event of overproduction of the photovoltaic system. FEATURES · Inverter air-water heat pump with R32 refrigerant · Energy efficiency class in average climate heating up to: A+++ (35°C) and A++ (55°C) · Powers available: 10 powers with refrigerant R32 single-phase (4-6-8-10-12-14-16 kW) and three-phase (12-14-16 kW). · Production of DHW (Domestic Hot Water) at high temperature, up to 75°C. · DHW management: a water/water heat pump unit integrated in the internal unit supplies domestic hot water at high temperature regardless of the external climatic conditions. · Absolute continuity availability of DHW: guaranteed by the redundancy of the double refrigerantion circuit · Anti-legionella cycles that can be avoided using the high temperature refrigeration cycle. · Double stage electric heating elements as standard: activation of single or double heating element to support the heat pump by means of a simple electronic control configuration. Each stage is activated according to the actual need for thermal power, in order to optimise electricity consumption (supplied disabled by default). · Configurable set points: two set points in cooling, Three set points in heating (one of which for DHW): the set points can also be selected via remote contact. · Holiday and weekly programmer: heating/cooling, DHW, night-time. · Climatic curves with external air temperature probe: two curves available, one for cooling and one for heating. The climatic curves are used to vary the temperature of the water supplying the system according to the external climatic conditions, adjusting the thermal needs of the building, in order to achieve energy savings. · Refrigerant gases: R32* for the reversible circuit dedicated to air conditioning and R134a** for the high temperature circuit dedicated to the production of DHW. · Built-in 150 L high efficiency storage tank (tower version) with an exchange battery surface equal to 1.5 m2. · Operating limits: down to -25°C, +43°C (see technical manuals for details). · Integrated heating cable to prevent freezing of water in the tray for sizes 12-14-16 and 12T-14T-16T. The heating cable intervenes during machine defrost operations or when the ambient air is below -7°C and cuts out when it exceeds 4°C (85W power consumption). AQUADUE TECHNOLOGY HEATING MODE +DHW at high temperature Production of DHW guaranteed regardless of the outside temperature for optimal operation all year round, not guaranteed by traditional heat pumps. COOLING MODE +DHW at a high temperature with energy recovery The energy normally dissipated outside is recovered and used to produce DHW up to 75°C. DHW Module 75°C DHW The water-water cycle dedicated to the domestic water services exchanges with the return water of the air-conditioning system. DHW Module 75°C DHW 40°C COMFORT The air-water cycle is dedicated to uninterrupted COMFORT for the production of DHW. Energy recovery 12°C COMFORT 45°C * Equipment not hermetically sealed containing fluorinated gases with an equivalent GWP of 675 (R32) ** Non-hermetically sealed equipment containing fluorinated gas with GWP equivalent 1430 26 7°C Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV LAYOUT, DIMENSIONS, WEIGHT 17 5 16 6 14 15 7 2 98 1. Support structure 2. 3 bar safety valve 3. Main circuit heat exchanger 16 4. Expansion tank 4 5. Post-heating electric heating 3 element manifold 1 6. Air conditioner circuit circulation pump 7. 3-way valve 8. Electrical panel assembly 11 9. Touchscreen display 10. Compressor 12 11. Expansion valve 12. DHW circuit heat exchangers 10 13. DHW circuit circulation pump 14. DHW circuit evaporator water flow rate regulator 15. Water circuit pressure gauge 16. Flow switches 17. Automatic vent valves H Suspended indoor units 4 6 8 10 12 14 16 12T 14T 16T SMALL BIG A mm 500 500 500 500 500 500 500 500 500 500 B mm 280 280 280 280 280 280 280 280 280 280 C mm 288 288 288 288 288 288 288 288 288 288 H mm 1116 1116 1116 1116 1116 1116 1116 1116 1116 1116 Weight kg 70 70 70 70 70 70 70 70 70 70 A C B 13 Tower indoor units 7 1. 3-way valve 4 6 8 10 12 14 16 12T 14T 16T 2. Air conditioner circuit circulation 1 12 pump SMALL BIG 10 13 9 3. Safety valves (DHW circuit 6 bar) A mm 600 600 600 600 600 600 600 600 600 600 B mm 600 600 600 600 600 600 600 600 600 600 2 8 4. Post-heating electric heating H mm 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 element manifold Weight kg 171 171 171 171 171 171 171 171 171 171 20 5. Safety valves air conditioner circuit 5 3 6 3 bar 11 14 6. Electric heating elements safety A B 4 thermostats 7. Automatic air vent valve 8. Air conditioner circuit heat H exchanger 15 9. Flow switches 10. Air conditioning circuit pressure gauge 16 11. DHW thermostatic accumulators 18 19 12. DHW circuit circulation pump 13. DHW circuit heat exchangers 14. DHW circuit expansion tank 15. DHW tank 16. Anode tester 17. Air conditioner circuit expansion tank 18. Touch screen display 17 19. Electrical panel assembly 20. DHW circuit evaporator water flow Outdoor units rate regulator 4 6 8 10 12 14 16 12T 14T 16T A mm 1008 1008 1118 1118 1118 1118 1118 1118 1118 1118 B mm 375 375 456 456 456 456 456 456 456 456 C mm 426 426 523 523 523 523 523 523 523 523 D mm 663 663 656 656 656 656 656 656 656 656 E mm 134 134 191 191 191 191 191 191 191 191 F mm 110 110 110 110 110 110 110 110 110 110 G mm 170 170 170 170 170 170 170 170 170 170 H mm 712 712 865 865 865 865 865 865 865 865 I mm 160 160 230 230 230 230 230 230 230 230 Weight kg 58 58 77 77 96 96 96 112 112 112 UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 27 SINGLE-PHASE R32 TECHNICAL DATA ODU Sherpa S3 E IDU Sherpa Aquadue S3 E IDU Sherpa Aquadue Tower S3 E 4 02284 02296 02298 6 02285 02296 02298 8 02286 02296 02298 10 02287 02296 02298 PUNCTUAL PERFORMANCE Compressor frequency Heating power COP Heating power COP Heating power COP Heating power COP Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Cooling power EER Cooling power (fancoils) EER (fancoils) Energy efficiency class in water heating 35°C SCOP Minimum Nominal Maximum Minimum Nominal Maximum Minimum Nominal Maximum Minimum Nominal Maximum a7/6 - w30/35 (a) kW 2,42 4,25 5,66 3,53 6,20 8,26 4,73 8,30 11,05 5,70 10,0 13,32 a7/6 - w30/35 (a) W/W - 5,15 - - 5,00 - - 5,20 - - 5,00 - a2/1 - w30/35 (b) kW 2,54 4,45 5,93 3,13 5,50 7,32 4,05 7,10 9,46 4,67 8,20 10,92 a2/1 - w30/35 (b) W/W - 4,05 - - 3,95 - - 4,10 - - 4,05 - a-7/-8 - w30/35 (c) kW 2,74 4,80 6,39 3,48 6,10 8,12 4,05 7,10 9,46 4,70 8,25 10,99 a-7/-8 - w30/35 (c) W/W - 3,15 - - 3,05 - - 3,25 - - 3,15 - a-15/-16 - w30/35 (d) kW 1,75 3,07 4,09 2,15 3,77 5,02 3,31 5,80 7,72 3,48 6,10 8,12 a-15/-16 - w30/35 (d) W/W - 2,88 - - 2,83 - - 2,98 - - 3,01 - a7/6 - w40/45 (f) kW 2,48 4,35 5,79 3,62 6,35 8,46 4,67 8,20 10,92 5,70 10,00 13,32 a7/6 - w40/45 (f) W/W - 3,80 - - 3,75 - - 3,95 - - 3,80 - a2/1 - w40/45 (g) kW 2,91 5,10 6,79 3,31 5,80 7,72 4,22 7,40 9,86 4,47 7,85 10,45 a2/1 - w40/45 (g) W/W - 3,00 - - 3,00 - - 3,25 - - 3,20 - a-7/-8 - w40/45 (h) kW 2,45 4,30 5,73 3,08 5,40 7,19 3,76 6,60 8,79 4,19 7,35 9,79 a-7/-8 - w40/45 (h) W/W - 2,35 - - 2,40 - - 2,55 - - 2,55 - a-15/-16 - w40/45 (i) kW 1,52 2,66 3,54 1,86 3,27 4,35 2,87 5,04 6,71 3,03 5,31 7,07 a-15/-16 - w40/45 (i) W/W - 2,02 - - 1,98 - - 2,32 - - 2,34 - a35 - w23/18 (l) kW 2,41 4,50 5,52 3,51 6,55 8,03 4,50 8,40 10,30 5,36 10,00 12,27 a35 - w23/18 (l) W/W - 5,55 - - 4,90 - - 5,05 - - 4,80 - a35 - w12/7 (m) kW 2,52 4,70 5,77 3,75 7,00 8,59 3,97 7,40 9,08 4,40 8,20 10,06 a35 - w12/7 (m) W/W - 3,45 - - 3,00 - - 3,38 - - 3,30 - Warmer Climate Warmer Climate 6,46 6,57 6,99 7,09 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C SCOP Warmer Climate s % Average Climate Average Climate 255,4% 4,85 259,8% 4,95 276,6% 5,22 280,5% 5,20 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C Average Climate s % Cold Climate 191,0% 195,0% 205,6% 204,8% EFFICIENCIES SCOP Cold Climate 4,06 4,21 4,33 4,32 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Cold Climate s % Warmer Climate 159,5% 165,3% 170,0% 169,8% SCOP Warmer Climate 4,15 4,21 4,51 4,62 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Warmer Climate s % Average Climate 163,1% 165,4% 177,2% 181,7% ELECTRICAL DATA NOISE LEVEL COOLING CIRCUIT SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C SCOP s (Seasonal efficiency for space heating) Indoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) Indoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) Outdoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) Outdoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) System circulator absorption Supply voltage indoor unit Maximum current absorbed indoor unit with additional resistors active Maximum power absorbed indoor unit with additional active heating elements Additional electric heating elements Supply voltage outdoor unit Outdoor unit maximum absorbed current Outdoor unit maximum absorbed power Compressor type Refrigerant inlet connection diameter Coolant gas Global warming potential Refrigerant gas charge Additional charge above 15m Refrigerant piping length limit Refrigerant piping length limit without minimum surface check according to IEC 60335-2-40:2018 Hydraulic connections for the technical water system System technical water expansion tank capacity Load profile according to EN16147 DHW production energy efficiency class HW (seasonal production efficiency DHW) Boiler volume Boiler interior surface material Heat exchanger in the boiler Type and thickness of boiler insulation Specific dispersion DHW expansion tank capacity DHW hydraulic connections DHW circuit heating power COP DHW circuit DHW circuit heating power COP DHW circuit Sound power indoor unit in heating/cooling + DHW circuit DHW circuit circulator absorption DHW circuit coolant gas DHW circuit global warming potential DHW circuit coolant gas load Average Climate 3,31 3,52 3,37 3,47 Average Climate s % 129,5% 137,9% 131,6% 135,7% Cold Climate Cold Climate 2,63 2,85 2,88 2,99 Cold Climate s % 102,1% 111,1% 112,1% 116,5% dB(A) 46/40 46/40 46/42 46/42 (n) dB(A) 38/32 38/32 38/36 38/36 dB(A) 56/52 58/53 59/54 60/55 (o) dB(A) 36/32 38/33 39/34 40/35 W 3 - 87 3 - 87 3 - 87 3 - 87 V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 A 18,00 18,00 18,00 18,00 kW 4,05 4,05 4,05 4,05 kW 1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5 V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 A 10 11 14 16 kW 2,2 2,6 3,3 3,6 Twin Rotary DC Inverter Twin Rotary DC Inverter Twin Rotary DC Inverter Twin Rotary DC Inverter " 1/4"-5/8" 1/4' -5/8' 3/8"-5/8" 3/8"-5/8" (p) R32 R32 R32 R32 GWP 675 675 675 675 kg 1,5 1,5 1,65 1,65 g/m 20 20 38 38 min - max m 2 - 30 2-30 2 - 30 2 - 30 max (q) m 30 30 20 20 " 1" 1' 1" 1" l 8 8 8 8 L L L L Average Climate Average Climate % 106% 106% 86% 86% l 150 150 150 150 DD12 glazed steel S235JR DD12 glazed steel S235JR DD12 glazed steel S235JR DD12 glazed steel S235JR m² 1,5 1,5 1,5 1,5 Hard expanded polyurethane 55 mm Hard expanded polyurethane 55 mm Hard expanded polyurethane 55 mm Hard expanded polyurethane 55 mm W/K 2 2 2 2 l 7 7 7 7 " 3/4" 3/4' 3/4" 3/4" w35 - w55 (r) kW 2,15 2,15 2,15 2,15 w35 - w55 (r) W/W 3,12 3,12 3,12 3,12 w12 - w55 (s) kW 1,60 1,60 1,60 1,6 w12 - w55 (s) W/W 2,58 2,58 2,58 2,58 dB(A) 49 49 49 49 W 3 - 43 3 - 43 3 - 43 3 - 43 (t) R134a R134a R134a R134a GWP 1430 1430 1430 1430 kg 0,35 0,35 0,35 0,35 HYDRAULIC DATA INTEGRATED DHW BOILER SECONDARY DHW COOLING CIRCUIT (a) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 30°C/35°C (b) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 30°C/35°C (c) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 30°C/35°C (d) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 30°C/35°C (f) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 40°C/45°C (g) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 40°C/45°C (h) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 40°C/45°C (i) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 40°C/45°C (l) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 23°C/18°C (m) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 12°C/7°C (n) Sound pressure values measured at a distance of 1 m in a semi-anechoic chamber (o) Sound pressure values measured at a distance of 4 m in free field distance (p) Non-airtightally sealed equipment containing fluorinated GAS (q) maximum length of the refrigeration pipes beyond which checks on the minimum surface of the installation rooms are necessary, check the technical manual (r) Heating circuit water temperature 35°C/Outlet water temperature 55°C (s) Heating circuit water temperature 12°C/Outlet water temperature 55°C (t) Non-hermetically sealed equipment containing fluorinated GAS ONLY FOR SHERPA AQUADUE TOWER 28 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV SINGLE-PHASE R32 TECHNICAL DATA ODU Sherpa S3 E IDU Sherpa Aquadue S3 E IDU Sherpa Aquadue Tower S3 E 12 02288 02297 02299 14 02289 02297 02299 16 02290 02297 02299 Compressor frequency Heating power Minimum Nominal Maximum Minimum Nominal Maximum Minimum Nominal Maximum a7/6 - w30/35 (a) kW 5,65 12,10 15,79 6,77 14,50 18,92 7,47 16,00 20,88 COP a7/6 - w30/35 (a) W/W - 4,95 - - 4,70 - - 4,50 - Heating power COP a2/1 - w30/35 (b) kW 4,34 9,30 12,14 5,32 11,40 14,88 6,07 13,00 16,96 a2/1 - w30/35 (b) W/W - 3,95 - - 3,65 - - 3,50 - Heating power a-7/-8 - w30/35 (c) kW 4,67 10,00 13,05 5,60 12,00 15,66 6,21 13,3 17,35 COP Heating power a-7/-8 - w30/35 (c) W/W - 3,00 - - 2,80 - - 2,70 - a-15/-16 - w30/35 (d) kW 3,43 7,35 9,59 3,71 7,94 10,36 4,37 9,35 12,20 PUNCTUAL PERFORMANCE COP Heating power (fancoils) COP (fancoils) a-15/-16 - w30/35 (d) W/W - 2,88 - - 2,85 - - 2,66 - a7/6 - w40/45 (f) kW 5,74 12,30 16,05 6,63 14,20 18,53 7,47 16,00 20,88 a7/6 - w40/45 (f) W/W - 3,80 - - 3,65 - - 3,60 - Heating power (fancoils) COP (fancoils) Heating power (fancoils) a2/1 - w40/45 (g) kW 5,00 10,70 13,96 5,46 11,70 15,27 5,98 12,80 16,70 a2/1 - w40/45 (g) W/W - 3,00 - - 2,86 - - 2,85 - a-7/-8 - w40/45 (h) kW 4,76 10,20 13,31 5,51 11,80 15,40 6,02 12,90 16,83 COP (fancoils) Heating power (fancoils) COP (fancoils) a-7/-8 - w40/45 (h) W/W - 2,40 - - 2,35 - - 2,23 - a-15/-16 - w40/45 (i) kW 3,10 6,63 8,65 3,34 7,16 9,34 3,93 8,41 10,97 a-15/-16 - w40/45 (i) W/W - 2,32 - - 2,29 - - 2,03 - Cooling power EER Cooling power (fancoils) a35 - w23/18 (l) kW 5,60 12,00 14,29 6,31 13,00 16,08 6,96 13,50 17,75 a35 - w23/18 (l) W/W - 4,00 - - 3,70 - - 3,61 - a35 - w12/7 (m) kW 5,42 11,60 13,82 5,93 12,70 15,13 6,54 14,00 16,67 EER (fancoils) Energy efficiency class in water heating 35°C SCOP a35 - w12/7 (m) W/W - 2,75 - Warmer Climate Warmer Climate 6,48 - 2,55 - 6,58 - 2,45 - 6,47 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C SCOP Warmer Climate s % Average Climate Average Climate 256,1% 4,81 260,3% 4,72 255,6% 4,62 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C Average Climate s % Cold Climate 189,4% 185,7% 181,7% EFFICIENCIES SCOP Cold Climate 4,08 4,07 4,02 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Cold Climate s % Warmer Climate 160,2% 159,6% 157,8% SCOP Warmer Climate 4,43 4,49 4,48 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Warmer Climate s % Average Climate 174,1% 176,5% 176,1% SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Average Climate Average Climate s % Cold Climate 3,45 135,1% 3,47 135,6% 3,41 133,3% SCOP Cold Climate s (Seasonal efficiency for space heating) Cold Climate s % Indoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) dB(A) 3,02 117,8% 48/46 3,05 118,9% 48/46 3,12 121,8% 48/46 ELECTRICAL DATA NOISE LEVEL Indoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) Outdoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) Outdoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) (n) dB(A) dB(A) (o) dB(A) 40/38 64/60 44/40 40/38 65/62 45/42 40/38 68/64 48/44 System circulator absorption Supply voltage indoor unit Maximum current absorbed indoor unit with additional resistors active W V/ph/Hz A 8 - 140 220-240/1/50 31,0 8 - 140 220-240/1/50 31,0 8 - 140 220-240/1/50 31,0 Maximum power absorbed indoor unit with additional active heating elements Additional electric heating elements Supply voltage outdoor unit kW kW V/ph/Hz 7,05 3,0+3,0 220-240/1/50 7,05 3,0+3,0 220-240/1/50 7,05 3,0+3,0 220-240/1/50 Outdoor unit maximum absorbed current Outdoor unit maximum absorbed power Compressor type A 23 kW 5,4 Twin Rotary DC Inverter 25 5,7 Twin Rotary DC Inverter 25 5,7 Twin Rotary DC Inverter COOLING CIRCUIT Refrigerant inlet connection diameter Coolant gas " (p) 3/8"-5/8" R32 3/8"-5/8" R32 3/8"-5/8" R32 Global warming potential GWP 675 675 675 Refrigerant gas charge Additional charge above 15m kg 1,84 1,84 1,84 g/m 38 38 38 Refrigerant piping length limit min - max m 2 - 30 2 - 30 2 - 30 Refrigerant piping length limit without minimum surface check according to IEC 60335-2-40:2018 max (q) m 15 15 15 Hydraulic connections for the technical water system " 1" 1" 1" HYDRAULIC DATA System technical water expansion tank capacity l 8 8 8 INTEGRATED DHW BOILER Load profile according to EN16147 DHW production energy efficiency class HW (seasonal production efficiency DHW) Boiler volume Boiler interior surface material Average Climate Average Climate L % 81% l 150 DD12 glazed steel S235JR L 81% 150 DD12 glazed steel S235JR L 81% 150 DD12 glazed steel S235JR Heat exchanger in the boiler Type and thickness of boiler insulation Specific dispersion m² 1,5 1,5 1,5 Hard expanded polyurethane 55 mm Hard expanded polyurethane 55 mm Hard expanded polyurethane 55 mm W/K 2 2 2 DHW expansion tank capacity DHW hydraulic connections DHW circuit heating power l 7 7 7 " 3/4" 3/4" 3/4" w35 - w55 (r) kW 2,15 2,15 2,15 SECONDARY DHW COOLING CIRCUIT COP DHW circuit DHW circuit heating power COP DHW circuit w35 - w55 (r) W/W 3,12 3,12 3,12 w12 - w55 (s) kW 1,60 1,60 1,60 w12 - w55 (s) W/W 2,58 2,58 2,58 Sound power indoor unit in heating/cooling + DHW circuit dB(A) 49 49 49 DHW circuit circulator absorption W 3 - 43 3 - 43 3 - 43 DHW circuit coolant gas (t) R134a R134a R134a DHW circuit global warming potential DHW circuit coolant gas load GWP 1430 1430 1430 kg 0,35 0,35 0,35 (a) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 30°C/35°C (b) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 30°C/35°C (c) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 30°C/35°C (d) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 30°C/35°C (f) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 40°C/45°C (g) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 40°C/45°C (h) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 40°C/45°C (i) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 40°C/45°C (l) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 23°C/18°C (m) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 12°C/7°C (n) Sound pressure values measured at a distance of 1 m in a semi-anechoic chamber (o) Sound pressure values measured at a distance of 4 m in free field distance (p) Non-airtightally sealed equipment containing fluorinated GAS (q) maximum length of the refrigeration pipes beyond which checks on the minimum surface of the installation rooms are necessary, check the technical manual (r) Heating circuit water temperature 35°C/Outlet water temperature 55°C (s) Heating circuit water temperature 12°C/Outlet water temperature 55°C (t) Non-hermetically sealed equipment containing fluorinated GAS UNICO MONO AND MULTISPLIT ONLY FOR SHERPA AQUADUE TOWER PORTABLES Catalogue 2024 | January edition 29 THREE-PHASE R32 TECHNICAL DATA 12T 14T 16T ODU Sherpa S3 E 02291 02292 02293 IDU Sherpa Aquadue S3 E 02297 02297 02297 IDU Sherpa Aquadue Tower S3 E 02299 02299 02299 Compressor frequency Minimum Nominal Maximum Minimum Nominal Maximum Minimum Nominal Maximum Heating power a7/6 - w30/35 (a) kW 5,65 12,10 15,79 6,77 14,50 18,92 7,47 16,00 20,88 COP a7/6 - w30/35 (a) W/W - 4,95 - - 4,70 - - 4,50 - Heating power a2/1 - w30/35 (b) kW 4,34 9,30 12,14 5,32 11,40 14,88 6,07 13,00 16,96 COP a2/1 - w30/35 (b) W/W - 3,95 - - 3,65 - - 3,50 - Heating power a-7/-8 - w30/35 (c) kW 4,67 10,00 13,05 5,60 12,00 15,66 6,21 13,30 17,35 COP a-7/-8 - w30/35 (c) W/W - 3,00 - - 2,80 - - 2,70 - PUNCTUAL PERFORMANCE Heating power a-15/-16 - w30/35 (d) kW 3,43 7,35 9,59 3,71 7,94 10,36 4,37 9,35 12,20 COP a-15/-16 - w30/35 (d) W/W - 2,88 - - 2,85 - - 2,66 - Heating power (fancoils) a7/6 - w40/45 (f) kW 5,74 12,30 16,05 6,63 14,20 18,53 7,47 16,00 20,88 COP (fancoils) a7/6 - w40/45 (f) W/W - 3,80 - - 3,65 - - 3,60 - Heating power (fancoils) a2/1 - w40/45 (g) kW 5,00 10,70 13,96 5,46 11,70 15,27 5,98 12,80 16,70 COP (fancoils) a2/1 - w40/45 (g) W/W - 3,00 - - 2,86 - - 2,85 - Heating power (fancoils) a-7/-8 - w40/45 (h) kW 4,76 10,20 13,31 5,51 11,80 15,40 6,02 12,90 16,83 COP (fancoils) a-7/-8 - w40/45 (h) W/W - 2,40 - - 2,35 - - 2,23 - Heating power (fancoils) a-15/-16 - w40/45 (i) kW 3,10 6,63 8,65 3,34 7,16 9,34 3,93 8,41 10,97 COP (fancoils) a-15/-16 - w40/45 (i) W/W - 2,32 - - 2,29 - - 2,03 - Cooling power a35 - w23/18 (l) kW 5,60 12,00 14,29 6,31 13,00 16,08 6,96 13,50 17,75 EER a35 - w23/18 (l) W/W - 4,00 - - 3,70 - - 3,61 - Cooling power (fancoils) a35 - w12/7 (m) kW 5,42 11,60 13,82 5,93 12,70 15,13 6,54 14,00 16,67 EER (fancoils) a35 - w12/7 (m) W/W - 2,75 - - 2,55 - - 2,45 - Energy efficiency class in water heating 35°C Warmer Climate SCOP Warmer Climate 6,47 6,57 6,28 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C Warmer Climate s % Average Climate 255,6% 259,8% 248,1% SCOP Average Climate 4,81 4,72 4,62 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C Average Climate s % Cold Climate 189,3% 185,6% 181,6% EFFICIENCIES SCOP Cold Climate 4,08 4,07 4,02 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Cold Climate s % Warmer Climate 160,2% 159,6% 157,8% SCOP Warmer Climate 4,42 4,49 4,47 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Warmer Climate s % Average Climate 173,8% 176,4% 175,9% SCOP Average Climate 3,45 3,47 3,41 s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Average Climate s % Cold Climate 135,1% 135,6% 133,2% SCOP Cold Climate 3,02 3,05 3,12 s (Seasonal efficiency for space heating) Cold Climate s % Indoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) dB(A) 117,7% 48/46 118,9% 48/46 121,8% 48/46 ELECTRICAL DATA NOISE LEVEL Indoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) (n) dB(A) 40/38 40/38 40/38 Outdoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) dB(A) 64/60 65/62 68/64 Outdoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) (o) dB(A) 44/40 45/42 48/44 System circulator absorption W 8 - 140 8 - 140 8 - 140 Supply voltage indoor unit V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Maximum current absorbed indoor unit with additional resistors active A 31,0 31,0 31,0 Maximum power absorbed indoor unit with additional active heating elements kW 7,05 7,05 7,05 Additional electric heating elements kW 3,0+3,0 3,0+3,0 3,0+3,0 Supply voltage outdoor unit V/ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 Outdoor unit maximum absorbed current A 8 8 8 Outdoor unit maximum absorbed power kW 5,4 5,7 5,7 Compressor type Twin Rotary DC Inverter Twin Rotary DC Inverter Twin Rotary DC Inverter Refrigerant inlet connection diameter " 3/8"-5/8" 3/8"-5/8" 3/8"-5/8" COOLING CIRCUIT Coolant gas (p) R32 R32 R32 Global warming potential GWP 675 675 675 Refrigerant gas charge kg 1,84 1,84 1,84 Additional charge above 15m g/m 38 38 38 Refrigerant piping length limit min - max m 2 - 30 2 - 30 2 - 30 Refrigerant piping length limit without minimum surface check according to IEC 60335-2-40:2018 max (q) m 15 15 15 HYDRAULIC DATA Hydraulic connections for the technical water system " 1" 1" 1" System technical water expansion tank capacity l 8 8 8 Load profile according to EN16147 L L L INTEGRATED DHW BOILER DHW production energy efficiency class Average Climate HW (seasonal production efficiency DHW) Average Climate % 81% 81% 81% Boiler volume l 150 150 150 Boiler interior surface material DD12 glazed steel S235JR DD12 glazed steel S235JR DD12 glazed steel S235JR Heat exchanger in the boiler m² 1,5 1,5 1,5 Type and thickness of boiler insulation Hard expanded polyurethane 55 mm Hard expanded polyurethane 55 mm Hard expanded polyurethane 55 mm Specific dispersion W/K 2 2 2 DHW expansion tank capacity l 7 7 7 DHW hydraulic connections " 3/4" 3/4" 3/4" SECONDARY DHW COOLING CIRCUIT DHW circuit heating power COP DHW circuit DHW circuit heating power w35 - w55 (r) kW 2,15 2,15 2,15 w35 - w55 (r) W/W 3,12 3,12 3,12 w12 - w55 (s) kW 1,60 1,60 1,60 COP DHW circuit w12 - w55 (s) W/W 2,58 2,58 2,58 Sound power indoor unit in heating/cooling + DHW circuit dB(A) 49 49 49 DHW circuit circulator absorption DHW circuit coolant gas DHW circuit global warming potential W 3 - 43 3 - 43 3 - 43 (t) R134a R134a R134a GWP 1430 1430 1430 DHW circuit coolant gas load kg 0,35 0,35 0,35 (a) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 30°C/35°C (b) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 30°C/35°C (c) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 30°C/35°C (d) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 30°C/35°C (f) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 40°C/45°C (g) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 40°C/45°C (h) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 40°C/45°C (i) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 40°C/45°C (l) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 23°C/18°C (m) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 12°C/7°C (n) Sound pressure values measured at a distance of 1 m in a semi-anechoic chamber (o) Sound pressure values measured at a distance of 4 m in free field distance (p) Non-airtightally sealed equipment containing fluorinated GAS (q) maximum length of the refrigeration pipes beyond which checks on the minimum surface of the installation rooms are necessary, check the technical manual (r) Heating circuit water temperature 35°C/Outlet water temperature 55°C (s) Heating circuit water temperature 12°C/Outlet water temperature 55°C (t) Non-hermetically sealed equipment containing fluorinated GAS ONLY FOR SHERPA AQUADUE TOWER 30 Catalogue 2024 | January edition BMS HEAT PUMPS Cooling w7 - a35 Cooling capacity kw 4.70 First circuit + DHW yield kw 0.00 second circuit data Absorption kw 1.36 EER COP 3.45 4 DHW w65 - w12 0.64 1,28 0.56 2.30 Cooling w7 - A35 DHW w65 - w12 4.70 1.28 1.17 4.03 Cooling w7 - a35 7.00 0.00 2.33 3.00 6 DHW w65 - w12 0.64 1.28 0.56 2.30 Cooling w7 - A35 DHW w65 - w12 7.00 1.28 2.00 3.50 Cooling w7 - a35 7.40 0.00 2.19 3.38 8 DHW w65 - w12 0.64 1.28 0.56 2.30 Cooling w7 - A35 DHW w65 - w12 7.40 1.28 1.87 3.95 Cooling w7 - a35 8.20 0.00 2.48 3.30 10 DHW w65 - w12 0.64 1.28 0.56 2.30 Cooling w7 - A35 DHW w65 - w12 8.20 1.28 2.13 3.85 12 14 16 12T 14T 16T Cooling DHW w65 Cooling w7 Cooling DHW w65 Cooling w7 Cooling DHW w65 Cooling w7 Cooling DHW w65 Cooling w7 Cooling DHW w65 Cooling w7 Cooling DHW w65 Cooling w7 w7 - a35 - w12 - A35 DHW w7 - a35 - w12 - A35 DHW w7 - a35 - w12 - A35 DHW w7 - a35 - w12 - A35 DHW w7 - a35 - w12 - A35 DHW w7 - a35 - w12 - A35 DHW w65 - w12 w65 - w12 w65 - w12 w65 - w12 w65 - w12 w65 - w12 Cooling capacity kw 11.60 0.64 11.60 12.70 0.64 12.70 14.00 0.64 14.00 11.60 0.64 11.60 12.70 0.64 12.70 14.00 0.64 14.00 First circuit + DHW yield kw 0.00 1.28 1.28 0.00 1.28 1.28 0.00 1.28 1.28 0.00 1.28 1.28 0.00 1.28 1.28 0.00 1.28 1.28 second circuit data Absorption kw 4.22 0.56 3.61 4.98 0.56 4.26 5.71 0.56 4.89 4.22 0.56 3.61 4.98 0.56 4.26 5.71 0.56 4.89 EER COP 2.75 2.30 3.21 2.55 2.30 2.98 2.45 2.30 2.86 2.75 2.30 3.21 2.55 2.30 2.98 2.45 2.30 2.86 COOLING + DHW WITH ENERGY RECOVERY During summer operation in cooling mode, the cycle dedicated to DHW production extracts heat from return water from the system circuit. The cooling requirements of the building is partially satisfied by the DHW cycle and the comfort refrigerating cycle must deliver less power by reducing the speed of the inverter compressor. The heat taken from the system is recovered in hot water for domestic use. The efficiency of the integrated system increases (ratio between the energy produced and the energy absorbed from the mains). FAN COIL UNITS HRV UNICO 80 PERFORMANCE AND ENERGY ADVANTAGES 75 In adverse weather conditions traditional heat pumps decrease thermal output 70 producing water at a lower temperature. Sherpa AQUADUE® as well as extending the area of operation ensures a constant heat output, in the production of 65 Domestic Hot Water. The double refrigerator circuit allows higher DHW production 60 temperatures thanks to the water-water circuit which are independent of outside air temperature. In summer cooling operation the refrigeration cycle dedicated to DHW 55 production removes heat from the comfort circuit increasing the overall efficiency of the system. 50 LEAVING WATER TEMPERATURE 45 40 35 30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 OUTDOOR AIR TEMPERATURE Traditional heat pump working area (R32) ACCESSORIES Sherpa Aquadue heat pump DHW working area STORAGE TANKS / PUFFER OTHER CONTROLS B0916 B0623 B0624 B0931 B0918 B0961 01804 01805 01806 01807 01808 01199 01200 Kit 3-way valve for DHW Outdoor air temperature probe kit Kit DHW storage tank sensor Remote control display kit 10 m Kit Sherpa Flex Box AS Kit Sherpa Flex Box AS RAL 9016 HE 200 L storage tank HE 300 L storage tank HES 300 L solar storage tank Hybride boiler HY 300 L HYS 300 L solar hybrid storage tank Thermal accumulation 50 L Thermal accumulation 100 L Optional accessory | Standard accessory | Accessory not compatible suspended tower 10 10 Accessory description on page 54 Please note that optional accessories are available for purchase with all models of the heat pump. When compatibility is only possible with certain sizes, the information is shown in the table. Standard accessories are already included in the heat pump code. Catalogue 2024 | January edition 31 MONO AND MULTISPLIT PORTABLES SHERPA S3 Traditional split heat pumps, suspended and tower versions Compatible with: COMPACT TECHNOLOGY The engineering of the components and the reduced shapes allow it to be installed inside a kitchen cabinet. DOMESTIC HOT WATER UP TO 60°C Sherpa supplies Domestic Hot Water with temperatures up to 60°C. PHOTOVOLTAIC INTEGRATION Thanks to the appropriate contact, it is possible to activate an increase in the heating/DHW temperature and a decrease in the cooling temperature, thereby accumulating thermal energy in the event of overproduction of the photovoltaic system. FEATURES · Inverter air-water heat pump with R32 coolant gas · Energy efficiency class in medium climate heating: A+++ (35°C) and A++ (55°C) · Available powers: 10 powers with single-phase R32 coolant gas (4-6-8-10-12- 14-16 kW) and three-phase (12-14-16 kW) · It supplies DHW with temperatures up to 60° C. · DHW management: Sherpa allows you to manage domestic hot water with extreme flexibility through two management modes: water probe inserted in the boiler or thermostat contact of the boiler (only for wall-mounted version). · Climatic curves] with external air temperature probe: two curves available, one for cooling and one for heating. · Smart Grid: the heat pump is set up to communicate with an intelligent electricity grid and is certified SG Ready, according to the requirements of the German BWP Institute. · Configurable set points: two set points in cooling, three set points in heating (one of which for DHW): the set points can also be selected through a remote contact. · Double-stage electric heaters as standard: configurable as single or doublestage, it can be activated to support the heat pump, through verification by the electronic control of the real thermal capacity of the heat pump. Each stage is activated according to the real need for thermal power, in order to optimise electricity consumption. · Daily holiday and weekly programmer: heating/cooling, DHW, night. · Complete management of anti-legionella cycles. · Coolant gas R32* · High efficiency integrated 200 L boiler (only for tower version). · Components included (only for tower version): system filling tap, 3-way valve. · Optional kit (only for tower version): thermostatic mixer and DHW expansion vessel. · Operating limits: up to -25°C, +43°C (see technical manuals for details). · Integrated heating cable to prevent water freezing in the drip pan for sizes 12-14-16 and 12T-14T-16T. The heating cable intervenes during the machine's defrost operations or when the ambient air is below -7°C and stops when it exceeds 4°C (electrical absorption of 85W). * Equipment not hermetically sealed containing fluorinated gases with an equivalent GWP of 675 (R32) 32 BMS HEAT PUMPS LAYOUT, DIMENSIONS, WEIGHT 87 15 10 1. Water inlet 2. 3 bar safety valve 3. Plate heat exchanger 4 4. Flow switch 6 5. Pressure gauge 6. Expansion tank 7. Electric heating element manifold 9 3 8. Automatic vent valve 9. Water pump 10. Support for wall installation 11. System water outlet 5 12. Electrical panel covers 13. Electrical panel assembly 14. Touch screen display 15. Manual reset electric heating element safety thermostat 11 2 1 H Suspended indoor units 4 6 8 10 12 14 16 12T 14T 16T SMALL BIG A mm 500 500 500 500 500 500 500 500 500 500 B mm 280 280 280 280 280 280 280 280 280 280 C mm 296 296 296 296 296 296 296 296 296 296 H mm 810 810 810 810 810 810 810 810 810 810 Weight kg 36 36 36 36 36 36 36 36 36 36 C A B FAN COIL UNITS HRV UNICO 14 13 12 Tower indoor units 10 8 9 15 1. 3-way valve 4 6 8 10 12 14 16 12T 14T 16T 2. Air conditioner circuit circulation 1 3 7 pump SMALL BIG 5 14 3. Safety valves A mm 600 600 600 600 600 600 600 600 600 600 B mm 600 600 600 600 600 600 600 600 600 600 4. Air conditioner circuit expansion 6 H mm 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 2 4 tank Weight kg 183 183 183 183 183 183 183 183 183 183 5. Post-heating electric heating element manifold 6. Safety valves air conditioner A B circuit 3 bar 7. Electric heating elements safety thermostats H 8. Air conditioner circuit heat 11 exchanger 9. Flow switches 10. Air conditioning circuit pressure gauge 11. Anode tester 12. Touchscreen display 13. Electrical panel assembly 14. Cable clamp 12 13 15. Automatic air vent valves Outdoor units 4 6 8 10 12 14 16 12T 14T 16T A mm 1008 1008 1118 1118 1118 1118 1118 1118 1118 1118 B mm 375 375 456 456 456 456 456 456 456 456 C mm 426 426 523 523 523 523 523 523 523 523 D mm 663 663 656 656 656 656 656 656 656 656 E mm 134 134 191 191 191 191 191 191 191 191 F mm 110 110 110 110 110 110 110 110 110 110 G mm 170 170 170 170 170 170 170 170 170 170 H mm 712 712 865 865 865 865 865 865 865 865 I mm 160 160 230 230 230 230 230 230 230 230 Weight kg 58 58 77 77 96 96 96 112 112 112 Catalogue 2024 | January edition 33 MONO AND MULTISPLIT PORTABLES PUNCTUAL PERFORMANCE EFFICIENCIES SINGLE-PHASE R32 TECHNICAL DATA 4 6 8 10 ODU Sherpa S3 E 02284 02285 02286 02287 IDU Sherpa S3 E 02294 02294 02294 02294 IDU Sherpa Tower S3 E 02300 02300 02300 02300 Compressor frequency Minimum Nominal Maximum Minimum Nominal Maximum Minimum Nominal Maximum Minimum Nominal Maximum Heating power a7/6 - w30/35 (a) kW 2,42 4,25 5,66 3,53 6,20 8,26 4,73 8,30 11,05 5,70 10,0 13,32 COP a7/6 - w30/35 (a) W/W - 5,15 - - 5,00 - - 5,20 - - 5,00 - Heating power a2/1 - w30/35 (b) kW 2,54 4,45 5,93 3,13 5,50 7,32 4,05 7,10 9,46 4,67 8,20 10,92 COP a2/1 - w30/35 (b) W/W - 4,05 - - 3,95 - - 4,10 - - 4,05 - Heating power a-7/-8 - w30/35 (c) kW 2,74 4,80 6,39 3,48 6,10 8,12 4,05 7,10 9,46 4,70 8,25 10,99 COP a-7/-8 - w30/35 (c) W/W - 3,15 - - 3,05 - - 3,25 - - 3,15 - Heating power a-15/-16 - w30/35 (d) kW 1,75 3,07 4,09 2,15 3,77 5,02 3,31 5,80 7,72 3,48 6,10 8,12 COP a-15/-16 - w30/35 (d) W/W - 2,88 - - 2,83 - - 2,98 - - 3,01 - Heating power (fancoils) a7/6 - w40/45 (f) kW 2,48 4,35 5,79 3,62 6,35 8,46 4,67 8,20 10,92 5,70 10,00 13,32 COP (fancoils) a7/6 - w40/45 (f) W/W - 3,80 - - 3,75 - - 3,95 - - 3,80 - Heating power (fancoils) a2/1 - w40/45 (g) kW 2,91 5,10 6,79 3,31 5,80 7,72 4,22 7,40 9,86 4,47 7,85 10,45 COP (fancoils) a2/1 - w40/45 (g) W/W - 3,00 - - 3,00 - - 3,25 - - 3,20 - Heating power (fancoils) a-7/-8 - w40/45 (h) kW 2,45 4,30 5,73 3,08 5,40 7,19 3,76 6,60 8,79 4,19 7,35 9,79 COP (fancoils) a-7/-8 - w40/45 (h) W/W - 2,35 - - 2,40 - - 2,55 - - 2,55 - Heating power (fancoils) a-15/-16 - w40/45 (i) kW 1,52 2,66 3,54 1,86 3,27 4,35 2,87 5,04 6,71 3,03 5,31 7,07 COP (fancoils) a-15/-16 - w40/45 (i) W/W - 2,02 - - 1,98 - - 2,32 - - 2,34 - Cooling power a35 - w23/18 (l) kW 2,41 4,50 5,52 3,51 6,55 8,03 4,50 8,40 10,30 5,36 10,00 12,27 EER a35 - w23/18 (l) W/W - 5,55 - - 4,90 - - 5,05 - - 4,80 - Cooling power (fancoils) a35 - w12/7 (m) kW 2,52 4,70 5,77 3,75 7,00 8,59 3,97 7,40 9,08 4,40 8,20 10,06 EER (fancoils) a35 - w12/7 (m) W/W - 3,45 - - 3,00 - - 3,38 - - 3,30 - Energy efficiency class in water heating 35°C Warmer Climate SCOP Warmer Climate 6,46 6,57 6,99 7,09 s (Seasonal efficiency for space heating) Warmer Climate s % 255,4% 259,8% 276,6% 280,5% Energy efficiency class in water heating 35°C Average Climate SCOP Average Climate 4,85 4,95 5,22 5,20 s (Seasonal efficiency for space heating) Average Climate s % 191,0% 195,0% 205,6% 204,8% Energy efficiency class in water heating 35°C Cold Climate SCOP Cold Climate 4,06 4,21 4,33 4,32 s (Seasonal efficiency for space heating) Cold Climate s % 159,5% 165,3% 170,0% 169,8% Energy efficiency class in water heating 55°C Warmer Climate SCOP Warmer Climate 4,15 4,21 4,51 4,62 s (Seasonal efficiency for space heating) Warmer Climate s % 163,1% 165,4% 177,2% 181,7% Energy efficiency class in water heating 55°C Average Climate SCOP Average Climate 3,31 3,52 3,37 3,47 s (Seasonal efficiency for space heating) Average Climate s % 129,5% 137,9% 131,6% 135,7% Energy efficiency class in water heating 55°C Cold Climate SCOP Cold Climate 2,63 2,85 2,88 2,99 s (Seasonal efficiency for space heating) Cold Climate s % 102,1% 111,1% 112,1% 116,5% Indoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) dB(A) 46/40 46/40 46/42 46/42 Indoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) (n) dB(A) 38/32 38/32 38/36 38/36 Outdoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) dB(A) 56/52 58/53 59/54 60/55 Outdoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) (o) dB(A) 36/32 38/33 39/34 40/35 System circulator absorption W 3 - 87 3 - 87 3 - 87 3 - 87 Supply voltage indoor unit V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Maximum current absorbed indoor unit with additional resistors active A 14,10 14,10 14,10 14,10 Maximum power absorbed indoor unit with additional active heating elements kW 3,22 3,22 3,22 3,22 Additional electric heating elements kW 1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5 Supply voltage outdoor unit V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Outdoor unit maximum absorbed current A 10 11 14 16 Outdoor unit maximum absorbed power kW 2,2 2,6 3,3 3,6 Compressor type Twin Rotary DC Inverter Twin Rotary DC Inverter Twin Rotary DC Inverter Twin Rotary DC Inverter Refrigerant inlet connection diameter " 1/4"-5/8" 1/4' -5/8' 3/8"-5/8" 3/8"-5/8" Coolant gas (p) R32 R32 R32 R32 Global warming potential GWP 675 675 675 675 Refrigerant gas charge kg 1,5 1,5 1,65 1,65 Additional charge above 15m g/m 20 20 38 38 Refrigerant piping length limit min - max m 2 - 30 2-30 2 - 30 2 - 30 Refrigerant piping length limit without minimum surface check according to IEC 60335-2-40:2018 max (q) m 30 30 20 20 Hydraulic connections " 1" 1' 1" 1" Capacity of expansion vessel l 8 8 8 8 Load profile according to EN16147 XL XL XL XL DHW production energy efficiency class Average Climate HW (seasonal production efficiency DHW) Average Climate % 125% 125% 123% 123% Boiler volume l 200 200 200 200 Boiler interior surface material DD12 glazed steel S235JR DD12 glazed steel S235JR DD12 glazed steel S235JR DD12 glazed steel S235JR Heat exchanger in the boiler m² 2,4 2,4 2,4 2,4 Type and thickness of boiler insulation Hard expanded Hard expanded Hard expanded Hard expanded polyurethane 55 mm polyurethane 55 mm polyurethane 55 mm polyurethane 55 mm Specific dispersion W/K 2 2 2 2 DHW expansion tank capacity l 7 7 7 7 DHW hydraulic connections " 3/4" 3/4' 3/4" 3/4" NOISE LEVEL ELECTRICAL DATA COOLING CIRCUIT HYDRAULIC DATA ONLY FOR SHERPA TOWER INTEGRATED DHW BOILER (a) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 30°C/35°C (b) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 30°C/35°C (c) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 30°C/35°C (d) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 30°C/35°C (f) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 40°C/45°C (g) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 40°C/45°C (h) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 40°C/45°C (i) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 40°C/45°C 34 (l) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 23°C/18°C (m) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 12°C/7°C (n) Sound pressure values measured at a distance of 1 m in a semi-anechoic chamber (o) Sound pressure values measured at a distance of 4 m in free field distance (p) Non-airtightally sealed equipment containing fluorinated GAS (q) maximum length of the refrigeration pipes beyond which checks on the minimum surface of the installation rooms are necessary, check the technical manual Catalogue 2024 | January edition BMS HEAT PUMPS PUNCTUAL PERFORMANCE FAN COIL UNITS EFFICIENCIES SINGLE-PHASE R32 TECHNICAL DATA 12 14 16 ODU Sherpa S3 E 02288 02289 02290 IDU Sherpa S3 E 02295 02295 02295 IDU Sherpa Tower S3 E 02301 02301 02301 Compressor frequency Minimum Nominal Maximum Minimum Nominal Maximum Minimum Nominal Maximum Heating power a7/6 - w30/35 (a) kW 5,65 12,10 15,79 6,77 14,50 18,92 7,47 16,00 20,88 COP a7/6 - w30/35 (a) W/W - 4,95 - - 4,70 - - 4,50 - Heating power a2/1 - w30/35 (b) kW 4,34 9,30 12,14 5,32 11,40 14,88 6,07 13,00 16,96 COP a2/1 - w30/35 (b) W/W - 3,95 - - 3,65 - - 3,50 - Heating power a-7/-8 - w30/35 (c) kW 4,67 10,00 13,05 5,60 12,00 15,66 6,21 13,3 17,35 COP a-7/-8 - w30/35 (c) W/W - 3,00 - - 2,80 - - 2,70 - Heating power a-15/-16 - w30/35 (d) kW 3,43 7,35 9,59 3,71 7,94 10,36 4,37 9,35 12,20 COP a-15/-16 - w30/35 (d) W/W - 2,88 - - 2,85 - - 2,66 - Heating power (fancoils) a7/6 - w40/45 (f) kW 5,74 12,30 16,05 6,63 14,20 18,53 7,47 16,00 20,88 COP (fancoils) a7/6 - w40/45 (f) W/W - 3,80 - - 3,65 - - 3,60 - Heating power (fancoils) a2/1 - w40/45 (g) kW 5,00 10,70 13,96 5,46 11,70 15,27 5,98 12,80 16,70 COP (fancoils) a2/1 - w40/45 (g) W/W - 3,00 - - 2,86 - - 2,85 - Heating power (fancoils) a-7/-8 - w40/45 (h) kW 4,76 10,20 13,31 5,51 11,80 15,40 6,02 12,90 16,83 COP (fancoils) a-7/-8 - w40/45 (h) W/W - 2,40 - - 2,35 - - 2,23 - Heating power (fancoils) a-15/-16 - w40/45 (i) kW 3,10 6,63 8,65 3,34 7,16 9,34 3,93 8,41 10,97 COP (fancoils) a-15/-16 - w40/45 (i) W/W - 2,32 - - 2,29 - - 2,03 - Cooling power a35 - w23/18 (l) kW 5,60 12,00 14,29 6,31 13,00 16,08 6,96 13,50 17,75 EER a35 - w23/18 (l) W/W - 4,00 - - 3,70 - - 3,61 - Cooling power (fancoils) a35 - w12/7 (m) kW 5,42 11,60 13,82 5,93 12,70 15,13 6,54 14,00 16,67 EER (fancoils) a35 - w12/7 (m) W/W - 2,75 - - 2,55 - - 2,45 - Energy efficiency class in water heating 35°C Warmer Climate SCOP Warmer Climate 6,48 6,58 6,47 s (Seasonal efficiency for space heating) Warmer Climate s % 256,1% 260,3% 255,6% Energy efficiency class in water heating 35°C Average Climate SCOP Average Climate 4,81 4,72 4,62 s (Seasonal efficiency for space heating) Average Climate s % 189,4% 185,7% 181,7% Energy efficiency class in water heating 35°C Cold Climate SCOP Cold Climate 4,08 4,07 4,02 s (Seasonal efficiency for space heating) Cold Climate s % 160,2% 159,6% 157,8% Energy efficiency class in water heating 55°C Warmer Climate SCOP Warmer Climate 4,43 4,49 4,48 s (Seasonal efficiency for space heating) Warmer Climate s % 174,1% 176,5% 176,1% Energy efficiency class in water heating 55°C Average Climate SCOP Average Climate 3,45 3,47 3,41 s (Seasonal efficiency for space heating) Average Climate s % 135,1% 135,6% 133,3% Energy efficiency class in water heating 55°C Cold Climate SCOP Cold Climate 3,02 3,05 3,12 s (Seasonal efficiency for space heating) Cold Climate s % 117,8% 118,9% 121,8% Indoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) dB(A) 48/46 48/46 48/46 Indoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) (n) dB(A) 40/38 40/38 40/38 Outdoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) dB(A) 64/60 65/62 68/64 Outdoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) (o) dB(A) 44/40 45/42 48/44 System circulator absorption W 8 - 140 8 - 140 8 - 140 Supply voltage indoor unit V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Maximum current absorbed internal unit with additional active heating elements A 27,20 27,20 27,20 Maximum power absorbed indoor unit with additional active heating elements kW 6,22 6,22 6,22 Additional electric heating elements kW 3,0+3,0 3,0+3,0 3,0+3,0 Supply voltage outdoor unit V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 Outdoor unit maximum absorbed current A 23 25 25 Outdoor unit maximum absorbed power kW 5,4 5,7 5,7 Compressor type Twin Rotary DC Inverter Twin Rotary DC Inverter Twin Rotary DC Inverter Refrigerant inlet connection diameter " 3/8"-5/8" 3/8"-5/8" 3/8"-5/8" Coolant gas (p) R32 R32 R32 Global warming potential GWP 675 675 675 Refrigerant gas charge kg 1,84 1,84 1,84 Additional charge above 15m g/m 38 38 38 Refrigerant piping length limit min - max m 2 - 30 2 - 30 2 - 30 Refrigerant piping length limit without minimum surface check according to IEC 60335-2-40:2018 max (q) m 15 15 15 Hydraulic connections " 1" 1" 1" Capacity of expansion vessel l 8 8 8 Load profile according to EN16147 XL XL XL DHW production energy efficiency class Average Climate HW (seasonal production efficiency DHW) Average Climate % 95% 95% 95% Boiler volume l 200 200 200 Boiler interior surface material DD12 glazed steel S235JR DD12 glazed steel S235JR DD12 glazed steel S235JR Heat exchanger in the boiler m² 2,4 2,4 2,4 Type and thickness of boiler insulation Hard expanded polyurethane 55 mm Hard expanded polyurethane 55 mm Hard expanded polyurethane 55 mm Specific dispersion W/K 2 2 2 DHW expansion tank capacity l 7 7 7 DHW hydraulic connections " 3/4" 3/4" 3/4" HRV NOISE LEVEL ELECTRICAL DATA UNICO COOLING CIRCUIT MONO AND MULTISPLIT HYDRAULIC DATA ONLY FOR SHERPA TOWER INTEGRATED DHW BOILER PORTABLES (a) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 30°C/35°C (b) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 30°C/35°C (c) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 30°C/35°C (d) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 30°C/35°C (f) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 40°C/45°C (g) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 40°C/45°C (h) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 40°C/45°C (i) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 40°C/45°C Catalogue 2024 | January edition (l) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 23°C/18°C (m) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 12°C/7°C (n) Sound pressure values measured at a distance of 1 m in a semi-anechoic chamber (o) Sound pressure values measured at a distance of 4 m in free field distance (p) Non-airtightally sealed equipment containing fluorinated GAS (q) maximum length of the refrigeration pipes beyond which checks on the minimum surface of the installation rooms are necessary, check the technical manual 35 PUNCTUAL PERFORMANCE EFFICIENCIES THREE-PHASE R32 TECHNICAL DATA 12T ODU Sherpa S3 E 02291 IDU Sherpa S3 E 02295 IDU Sherpa Tower S3 E 02301 Compressor frequency Minimum Nominal Maximum Heating power a7/6 - w30/35 (a) kW 5,65 12,10 15,79 COP a7/6 - w30/35 (a) W/W - 4,95 - Heating power a2/1 - w30/35 (b) kW 4,34 9,30 12,14 COP a2/1 - w30/35 (b) W/W - 3,95 - Heating power a-7/-8 - w30/35 (c) kW 4,67 10,00 13,05 COP a-7/-8 - w30/35 (c) W/W - 3,00 - Heating power a-15/-16 - w30/35 (d) kW 3,43 7,35 9,59 COP a-15/-16 - w30/35 (d) W/W - 2,88 - Heating power (fancoils) a7/6 - w40/45 (f) kW 5,74 12,30 16,05 COP (fancoils) a7/6 - w40/45 (f) W/W - 3,80 - Heating power (fancoils) a2/1 - w40/45 (g) kW 5,00 10,70 13,96 COP (fancoils) a2/1 - w40/45 (g) W/W - 3,00 - Heating power (fancoils) a-7/-8 - w40/45 (h) kW 4,76 10,20 13,31 COP (fancoils) a-7/-8 - w40/45 (h) W/W - 2,40 - Heating power (fancoils) a-15/-16 - w40/45 (i) kW 3,10 6,63 8,65 COP (fancoils) a-15/-16 - w40/45 (i) W/W - 2,32 - Cooling power a35 - w23/18 (l) kW 5,60 12,00 14,29 EER a35 - w23/18 (l) W/W - 4,00 - Cooling power (fancoils) a35 - w12/7 (m) kW 5,42 11,60 13,82 EER (fancoils) a35 - w12/7 (m) W/W - 2,75 - Energy efficiency class in water heating 35°C Warmer Climate SCOP Warmer Climate 6,47 s (Seasonal efficiency for space heating) Warmer Climate s % 255,6% Energy efficiency class in water heating 35°C Average Climate SCOP Average Climate 4,81 s (Seasonal efficiency for space heating) Average Climate s % 189,3% Energy efficiency class in water heating 35°C Cold Climate SCOP Cold Climate 4,08 s (Seasonal efficiency for space heating) Cold Climate s % 160,2% Energy efficiency class in water heating 55°C Warmer Climate SCOP Warmer Climate 4,42 s (Seasonal efficiency for space heating) Warmer Climate s % 173,8% Energy efficiency class in water heating 55°C Average Climate SCOP Average Climate 3,45 s (Seasonal efficiency for space heating) Average Climate s % 135,1% Energy efficiency class in water heating 55°C Cold Climate SCOP Cold Climate 3,02 s (Seasonal efficiency for space heating) Cold Climate s % 117,7% Indoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) dB(A) 48/46 Indoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) (n) dB(A) 40/38 Outdoor unit sound power (reg. EU 811-2013/UNI EN 12102:2022) dB(A) 64/60 Outdoor unit sound pressure (reg. EU 811-2013/UNI EN 12102:2022) (o) dB(A) 44/40 System circulator absorption W 8 - 140 Supply voltage indoor unit V/ph/Hz 220-240/1/50 Maximum current absorbed internal unit with additional active heating elements A 27,20 Maximum power absorbed indoor unit with additional active heating elements kW 6,22 Additional electric heating elements kW 3,0+3,0 Supply voltage outdoor unit V/ph/Hz 380-415/3/50 Outdoor unit maximum absorbed current A 8 Outdoor unit maximum absorbed power kW 5,4 Compressor type Twin Rotary DC Inverter Refrigerant inlet connection diameter " 3/8"-5/8" Coolant gas (p) R32 Global warming potential GWP 675 Refrigerant gas charge kg 1,84 Additional charge above 15m g/m 38 Refrigerant piping length limit min - max m 2 - 30 Refrigerant piping length limit without minimum surface check according to IEC 60335-2-40:2018 max (q) m 15 Hydraulic connections " 1" Capacity of expansion vessel l 8 Load profile according to EN16147 XL DHW production energy efficiency class Average Climate HW (seasonal production efficiency DHW) Average Climate % 95% Boiler volume l 200 Boiler interior surface material DD12 glazed steel S235JR Heat exchanger in the boiler m² 2,4 Type and thickness of boiler insulation Hard expanded polyurethane 55 mm Specific dispersion W/K 2 DHW expansion tank capacity l 7 DHW hydraulic connections " 3/4" Minimum 6,77 5,32 5,60 3,71 6,63 5,46 5,51 3,34 6,31 5,93 - 14T 02292 02295 02301 Nominal 14,50 4,70 11,40 3,65 12,00 2,80 7,94 2,85 14,20 3,65 11,70 2,86 11,80 2,35 7,16 2,29 13,00 3,70 12,70 2,55 Maximum 18,92 14,88 15,66 10,36 18,53 15,27 15,40 9,34 16,08 15,13 - 6,57 259,8% 4,72 185,6% 4,07 159,6% 4,49 176,4% 3,47 135,6% 3,05 118,9% 48/46 40/38 65/62 45/42 8 - 140 220-240/1/50 27,20 6,22 3,0+3,0 380-415/3/50 8 5,7 Twin Rotary DC Inverter 3/8"-5/8" R32 675 1,84 38 2 - 30 15 1" 8 XL 95% 200 DD12 glazed steel S235JR 2,4 Hard expanded polyurethane 55 mm 2 7 3/4" Minimum 7,47 6,07 6,21 4,37 7,47 5,98 6,02 3,93 6,96 6,54 - 16T 02293 02295 02301 Nominal 16,00 4,50 13,00 3,50 13,30 2,70 9,35 2,66 16,00 3,60 12,80 2,85 12,90 2,23 8,41 2,03 13,50 3,61 14,00 2,45 Maximum 20,88 16,96 17,35 12,20 20,88 16,70 16,83 10,97 17,75 16,67 - 6,28 248,1% 4,62 181,6% 4,02 157,8% 4,47 175,9% 3,41 133,2% 3,12 121,8% 48/46 40/38 68/64 48/44 8 - 140 220-240/1/50 27,20 6,22 3,0+3,0 380-415/3/50 8 5,7 Twin Rotary DC Inverter 3/8"-5/8" R32 675 1,84 38 2 - 30 15 1" 8 XL 95% 200 DD12 glazed steel S235JR 2,4 Hard expanded polyurethane 55 mm 2 7 3/4" NOISE LEVEL ELECTRICAL DATA COOLING CIRCUIT HYDRAULIC DATA ONLY FOR SHERPA TOWER INTEGRATED DHW BOILER (a) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 30°C/35°C (b) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 30°C/35°C (c) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 30°C/35°C (d) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 30°C/35°C (f) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 40°C/45°C (g) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 40°C/45°C (h) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 40°C/45°C (i) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 40°C/45°C 36 (l) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 23°C/18°C (m) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 12°C/7°C (n) Sound pressure values measured at a distance of 1 m in a semi-anechoic chamber (o) Sound pressure values measured at a distance of 4 m in free field distance (p) Non-airtightally sealed equipment containing fluorinated GAS (q) maximum length of the refrigeration pipes beyond which checks on the minimum surface of the installation rooms are necessary, check the technical manual Catalogue 2024 | January edition BMS HEAT PUMPS STORAGE TANKS / PUFFER CONTROLS ACCESSORIES B0971 B0972 B0918 B0961 B1120 B0916 B0917 B0623 B0624 B0931 01804 01805 01806 01807 01808 B0618 B0666 B0617 01199 01200 Thermostatic mixing valve kit for DHW Expansion tank kit for DHW Kit Sherpa Flex Box AS Kit Sherpa Flex Box AS RAL 9016 Sherpa Flex Box adapter kit Kit 3-way valve for DHW Solar thermal probe kit Outdoor air temperature probe kit Kit DHW storage tank sensor Remote control display kit 10 m HE 200 L storage tank HE 300 L storage tank HES 300 L solar storage tank Hybride boiler HY 300 L HYS 300 L solar hybrid storage tank Resistance for boiler 2 kW Resistance for boiler 3 kW Resistance flange kit Thermal accumulation 50 L Thermal accumulation 100 L Optional accessory | Standard accessory | Accessory not compatible suspended 10 10 NEW 10 tower Accessory description on page 54 FAN COIL UNITS HRV UNICO MONO AND MULTISPLIT PORTABLES Please note that optional accessories are available for purchase with all models of the heat pump. When compatibility is only possible with certain sizes, the information is shown in the table. Standard accessories are already included in the heat pump code. Catalogue 2024 | January edition 37 Heat Pump Controls In-depth analysis of the different control possibilities The Sherpa and Sherpa Aquadue heat pumps, in the wall-mounted or tower versions, can be configured using an easy and intuitive touchscreen interface, accessible both from the machine and from the optional control panel. STANDARD | Touchscreen on the machine MODES To deactivate the system (stand-by), set the cooling/ heating switch or take advantage of the special modes, which ensure maximum energy saving (eco), minimum night noise (night) or DHW production using all the power (turbo). SET POINT To change the different set points with a simple touch (if the set-point mode with climate curve is not enabled). TIMERS To access the programming available for climate comfort and DHW production, including night and holiday modes. PHOTOVOLTAIC CONTACT To activate a set point delta on the DHW, the heating and cooling, accumulating thermal energy when there is an overproduction of electricity from the photovoltaic system. SOLAR THERMAL PROBE To produce DHW with solar thermal only, inhibiting the heat pump in certain conditions, if the delivery temperature of the solar panels is above a certain value or if the difference between the delivery temperature of the panels and the boiler set point one is higher than the set value. 38 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS CLIMATIC CURVES To optimise energy saving, adapting the water temperature to the outside air temperature and therefore to the thermal load. From the standard touchscreen control it is also possible to manage: LOW TEMPERATURE ACTIVATION To activate the heaters and allow heating of the screed in the case of a radiant system. COMMUNICATION PROTOCOL For combination with home automation systems, choosing between the ModBus RTU or ASCII protocol. HRV UNICO MONO AND MULTISPLIT OPTIONAL | Remote control panel (code B0931) In cases where control of the heat pump is possible or preferable in an environment other than the one where the internal unit is installed, the control can easily be accessed remotely. Through the special kit for remote control panel, the touchscreen interface is thus accessible up to 10 metres away (cable length 10 metres). Catalogue 2024 | January edition 39 PORTABLES Kit Sherpa Flex Box Freestanding technical cabinet for Sherpa and Sherpa Aquadue split heat pumps, hanging version DOMESTIC WATER STORAGE TANK 150 LT STAINLESS STEEL High thermal insulation 50 mm in EPS with graphite to minimise dispersions (class C) TECHNICAL ACCUMULATION 28 LT STAINLESS STEEL (standard on return from the system) To ensure efficient and safe operation of the heat pump (class C) FREESTANDING TECHNICAL CABINET For maximum installation flexibility with a single product. In galvanised steel. Sherpa Flex Box AS kit is the technical cabinet that makes it possible to create a compact system in heat pump with high installation flexibility. The heat pump and the class C storage tanks make it possible to obtain a very high energy efficiency of the system, even in outdoor installation. B0918 B0961 B0931 B1120 Kit Sherpa Flex Box AS Kit Sherpa Flex Box AS RAL 9016 Remote control display kit 10 m NEW Sherpa Flex Box adapter kit FEATURES · Dimensions (W x D x H): 998 x 415 x 2280 mm · System connections from below or from the back · Condensation trap to prevent any dripping of the condensation on the bottom of the cabinet · Possible combination with display remote control kit (B0931) · The distribution and heat emission network downstream of Sherpa Flex Box AS must ensure the circulation of the minimum flow rate of the heat pump in all operating conditions by means of 3-way valves or by-pass systems, in addition, for heat pump sizes 8 and 10, the water content of the distribution network and of the fan coil units must be at least 10 litres (refer to the product installation manuals). TYPES OF INSTALLATION The technical cabinet must be installed in an area protected from the weather according to installation manual A. Outdoor support B. Outdoor semi-recessed C. Indoor support D. Indoor semi-recessed On request, code B0961 can be supplied with RAL 9016 powder-coating, (front/back for upper, lower side and front panels, no backs). 40 Catalogue 2024 | January edition BMS HEAT PUMPS COMPATIBILITY SHERPA AQUADUE · Sherpa Aquadue S2 E multi-purpose heat pumps, wall-mounted version, in sizes 4 and 6 (UI Sherpa Aquadue S2 E Small 02042). · Sherpa Aquadue S3 E multi-purpose heat pumps, wall-mounted version, in sizes 4, 6, 8 and 10 (UI Sherpa Aquadue S3 E Small 02296). 1. UI Sherpa Aquadue S2/S3 E Small | Code 02042/02296 2. Domestic hot water cylinder 150 liters -INOX AISI 316L 3. Technical storage tank plant 28 liters -INOX AISI 316L 4. Kettle return filter 5. Plant return filter 6. Sanitary expansion tank 12 liters 7. Sanitary safety valve 6 bar 8. Sanitary thermostatic mixing valve 9. Micrometric holder for By-Pass 10. Condensation drip pan FAN COIL UNITS Components included in codes B0918/B0961 HRV UNICO MONO AND MULTISPLIT Catalogue 2024 | January edition Components included in codes B0918/B0961 SHERPA COMPATIBILITY · Sherpa S2 E traditional heat pumps, wall-mounted version, in sizes 4 and 6 (UI Sherpa S2 E Small 02040). · Sherpa S3 E traditional heat pumps, wall-mounted version, in sizes 4, 6, 8 and 10 (UI Sherpa S3 E Small 02294). 1. UI Sherpa S2/S3 E Small (02040/02294) 2. Domestic hot water cylinder 150 liters -INOX AISI 316L 3. Technical storage tank plant 28 liters -INOX AISI 316L 4. Kettle return filter 5. Plant return filter 6. Sanitary expansion tank 12 liters 7. Sanitary safety valve 6 bar 8. Sanitary thermostatic mixing valve 9. Micrometric holder for By-Pass 10. Condensation drip pan 11. 3-way valve kit for DHW | Code B0916 12. Outdoor air temperature probe kit | Code B0623 13. DHW cylinder sensor kit | Code B0624 14. Flex Box Adapter Kit | Code B1120 41 PORTABLES SHERPA COLD Split heat pump for cold climates HIGH PERFORMANCE ALSO AT LOW TEMPERATURE The defrosting cycles of the machine are optimised to guarantee high performance even with low external temperatures. WIDE OPERATING LIMITS Sherpa Cold can work up to outdoor air temperatures of -32°C and + 48°C INVERTER SCROLL COMPRESSORS WITH STEAM INJECTION Technology that improves performance in low temperature applications. FEATURES · Air-to-water inverter heat pump · energy efficiency class in heating medium climate: up to A+++ (35°C) and A++ (55°C) · Energy efficiency class in heating cold climate: up to A+ (35°C) and A+ (55°C) · Available powers: 2 powers with single-phase R410A refrigerant (10-15 kW) and 2 powers with three-phase R410A refrigerant (15-18 kW) · Provides DHW with temperature up to 55° C. · Inverter steam-injected Scrollcompressor · Expansion valve: electronic · Refrigerant circuit with economizer · Color touchscreen remotecontrol panel · Maintenance of machineoutput even in cold outside temperatures · Optimization of machinedefrost cycles and excellent performance even at cold outside temperatures · Operating limits: down to -32°C, +48°C (see technical manuals for details) · Refrigerant gas R410A* · External air probe integrated in the machine · Devices supplied with the machine: · - metal frame for outdoor installation touch panel · - pair of 250 mm high metal feet with vibration dampers · - rear metal mesh for battery protection · - integration kit - relay for activation of boiler or other electrical resistance · - domestic hot water management kit - k1 relay, 1"1/4" 3-way valve, b3 probe · - heating resistor condensation drain pipe · - fan grille for noise reduction 800mm diameter (sizes 15,15T,18T) * Equipment not hermetically sealed containing fluorinated gases with an equivalent GWP of 2088. 42 BMS HEAT PUMPS FAN COIL UNITS LAYOUT, DIMENSIONS, WEIGHT Indoor Units 1. Vent valve 2. Plate heat exchanger 10 15 15 T 18 T 3. Circulation pump 4. Water inlet hose A mm 550 550 550 550 B mm 228 228 228 228 5. Water outlet hose C mm 147 147 147 147 (system) D mm 100 100 100 100 6. Water outlet hose (DHW) H mm 907 907 907 907 7. Gas passage hose Weight kg 50 50 50 50 8. Liquid passage hose 9. Flow meter 10. 3-way valve A B 11. Electrical panel H CD Outdoor units 1. Evaporator 2. Compressor 10 15 15 T 18 T 3. Filter 4. Liquid indicator 5. Inverter 6. Liquid tank 7. Electrical panel 8. Economiser 9. Ball valve A mm 1406 1591 1591 1591 B mm 550 546 546 546 C mm 259 259 259 259 D mm 225 225 225 225 E mm 949 1134 1134 1134 F mm 1167 1271 1271 1271 H mm 908 1012 1012 1012 Weight kg 160 200 200 200 10. Check valve 11. Electronic expansion valve 12. 4-way valve 13. Fan HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 43 PUNCTUAL PERFORMANCE TECHNICAL DATA ODU Sherpa Cold IDU Sherpa Cold Compressor frequency Heating power COP Heating power COP Heating power COP Heating power COP Heating power COP Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Cooling power EER Cooling power (fancoils) EER (fancoils) Energy efficiency class in water heating 35°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C SCOP s (Seasonal efficiency for space heating) Indoor unit sound power Indoor unit sound pressure Outdoor unit sound power (nominal) Outdoor unit sound pressure (nominal) System circulator absorption Supply voltage indoor unit Maximum absorbed current of the internal unit Maximum power consumption of the internal unit Additional electric heating elements Supply voltage outdoor unit Outdoor unit maximum absorbed current Outdoor unit maximum absorbed power Compressor type Refrigerant inlet connection diameter Coolant gas Global warming potential Refrigerant gas charge Refrigerant piping length limit without minimum surface verification Hydraulic connections Capacity of expansion vessel a7/6 - w30/35 (a) kW a7/6 - w30/35 (a) W/W a2/1 - w30/35 (b) kW a2/1 - w30/35 (b) W/W a-7/-8 - w30/35 (c) kW a-7/-8 - w30/35 (c) W/W a-15/-16 - w30/35 (d) kW a-15/-16 - w30/35 (d) W/W a-20/-19 - w30/35 (r) kW a-20/-19 - w30/35 (r) W/W a7/6 - w40/45 (f) kW a7/6 - w40/45 (f) W/W a2/1 - w40/45 (g) kW a2/1 - w40/45 (g) W/W a-7/-8 - w40/45 (h) kW a-7/-8 - w40/45 (h) W/W a-15/-16 - w40/45 (i) kW a-15/-16 - w40/45 (i) W/W a-20/-19 - w40/45 (s) W/W a-20/-19 - w40/45 (s) W/W a35 - w23/18 (l) kW a35 - w23/18 (l) W/W a35 - w12/7 (m) kW a35 - w12/7 (m) W/W Warmer Climate Warmer Climate Warmer Climate s % Average Climate Average Climate Average Climate s % Cold Climate Cold Climate Cold Climate s % Warmer Climate Warmer Climate Warmer Climate s % Average Climate Average Climate Average Climate s % Cold Climate Cold Climate Cold Climate s % dB(A) (n) dB(A) dB(A) (o) dB(A) W V/ph/Hz A kW kW V/ph/Hz A kW " (p) GWP kg (q) " l Minimum 3.90 4.80 4.17 3.72 3.28 3.90 4.80 4.17 3.68 3.17 3.53 2.71 - 10 02269 02276 Nominal 9.60 4.27 9.60 3.83 9.60 2.98 8.93 2.26 7.87 2.09 9.60 3.33 9.60 2.82 9.60 2.33 8.83 1.90 7.61 1.76 8.40 4.26 6.44 3.31 Maximum - 4.62 181.8 4.50 177.3 3.60 141,1 3.27 127.8 3.23 126.3 2.68 104.2 36 30 53.4 33.5 75 230/1/50 0.33 0.75 230/1/50 24.6 5.1 Scroll with injection See installation manual R410A 2088 5 - 1" - Minimum 5.51 6.82 6.26 5.52 4.88 5.51 6.82 6.26 5.36 4.80 4.08 3.13 - 15 02273 02277 Nominal 14.40 4.68 14.40 3.85 14.40 2.98 13.25 2.57 11.71 2.43 14.40 3.53 14.40 3.08 14.40 2.45 12.86 2.03 11.52 1.92 11.31 4.45 8.67 3.45 Maximum - 4.79 188.6 4.60 181.1 3.71 145.3 3.45 135.1 3.37 131.9 2.76 107.3 36 30 52.9 33 75 230/1/50 0.33 0.75 230/1/50 38.7 8.0 Scroll with injection See installation manual R410A 2088 6.5 - 1" - EFFICIENCIES ELECTRICAL DATA NOISE LEVEL COOLING CIRCUIT HYDRAULIC DATA (a) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 30°C/35°C (b) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 30°C/35°C (c) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 30°C/35°C (d) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 30°C/35°C (f) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 40°C/45°C (g) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 40°C/45°C (h) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 40°C/45°C (i) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 40°C/45°C (l) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 23°C/18°C 44 (m) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 12°C/7°C (n) Sound pressure values measured at a distance of 1 m in a semi-anechoic chamber (o) Sound pressure values measured at a distance of 4 m in free field distance (p) Non-airtightally sealed equipment containing fluorinated GAS (q) maximum length of the refrigeration pipes beyond which checks are necessary on the minimum surface of the installation rooms, check the technical manual (r) Heating mode, external air temperature -20°C b.s./-19°C b.u., inlet/outlet water temperature 30°C/35°C (s) Heating mode, external air temperature -20°C b.s./-19°C b.u., inlet/outlet water temperature 40°C/45°C Catalogue 2024 | January edition BMS HEAT PUMPS PUNCTUAL PERFORMANCE FAN COIL UNITS TECHNICAL DATA ODU Sherpa Cold IDU Sherpa Cold Compressor frequency Heating power a7/6 - w30/35 (a) kW COP Heating power a7/6 - w30/35 (a) W/W a2/1 - w30/35 (b) kW COP a2/1 - w30/35 (b) W/W Heating power COP Heating power a-7/-8 - w30/35 (c) kW a-7/-8 - w30/35 (c) W/W a-15/-16 - w30/35 (d) kW COP a-15/-16 - w30/35 (d) W/W Heating power COP a-20/-19 - w30/35 (r) a-20/-19 - w30/35 (r) W/W Heating power (fancoils) a7/6 - w40/45 (f) kW COP (fancoils) Heating power (fancoils) a7/6 - w40/45 (f) W/W a2/1 - w40/45 (g) kW COP (fancoils) a2/1 - w40/45 (g) W/W Heating power (fancoils) COP (fancoils) Heating power (fancoils) a-7/-8 - w40/45 (h) kW a-7/-8 - w40/45 (h) W/W a-15/-16 - w40/45 (i) kW COP (fancoils) a-15/-16 - w40/45 (i) W/W Heating power (fancoils) COP (fancoils) a-20/-19 - w40/45 (s) W/W a-20/-19 - w40/45 (s) W/W Cooling power a35 - w23/18 (l) kW EER Cooling power (fancoils) EER (fancoils) a35 - w23/18 (l) W/W a35 - w12/7 (m) kW a35 - w12/7 (m) W/W Energy efficiency class in water heating 35°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C Warmer Climate Warmer Climate Warmer Climate s % Average Climate SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C Average Climate Average Climate s % Cold Climate SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Cold Climate Cold Climate s % Warmer Climate SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Warmer Climate Warmer Climate s % Average Climate SCOP Average Climate s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C Average Climate s % Cold Climate SCOP Cold Climate s (Seasonal efficiency for space heating) Indoor unit sound power Indoor unit sound pressure Cold Climate s % dB(A) (n) dB(A) Outdoor unit sound power (nominal) dB(A) Outdoor unit sound pressure (nominal) System circulator absorption (o) dB(A) W Supply voltage indoor unit V/ph/Hz Maximum absorbed current of the internal unit with active heating elements A Internal unit maximum power consumption with active heating elements kW Additional electric heating elements kW Supply voltage outdoor unit Outdoor unit maximum absorbed current Outdoor unit maximum absorbed power V/ph/Hz A kW Compressor type Refrigerant inlet connection diameter Coolant gas " (p) Global warming potential GWP Refrigerant gas charge Refrigerant piping length limit without minimum surface verification Hydraulic connections kg (q) " Capacity of expansion vessel l Minimum 5.51 6.82 6.26 5.52 4.88 5.51 6.82 6.26 5.36 4.80 4.08 3.13 - 15 T 02274 02277 Nominal 14.40 4.68 14.40 3.85 14.40 2.98 13.25 2.57 11.71 2.43 14.40 3.53 14.40 3.08 14.40 2.45 12.86 2.03 11.52 1.92 11.31 4.45 8.67 3.45 Maximum - 4.79 188.6 4.60 181.1 3.71 145.3 3.45 135.1 3.37 131.9 2.76 107.3 36 30 52.9 33 75 230/1/50 0.33 0.75 400/3/50 12.8 8.0 Scroll with injection See installation manual R410A 2088 6.5 1" - Minimum 6.24 7.78 7.20 6.40 5.60 6.24 7.78 7.20 5.80 5.20 6.62 5.08 - 18 T 02275 02278 Nominal 17.28 4.34 17.28 3.37 17.28 2.61 15.36 2.23 13.44 2.03 17.28 3.05 17.28 2.80 17.28 2.20 13.92 1.90 12.48 1.79 15.72 4.11 12.34 2.99 Maximum - 4.66 183.7 4.45 175 3.44 134.6 3.19 124.7 3.13 122.2 2.51 97.4 37 31 54 34 85 230/1/50 0.33 0.75 400/3/50 13.6 8.5 Scroll with injection See installation manual R410A 2088 6.5 1" - EFFICIENCIES HRV ELECTRICAL DATA NOISE LEVEL UNICO COOLING CIRCUIT HYDRAULIC DATA MONO AND MULTISPLIT STORAGE TANKS / PUFFER ACCESSORIES ACCESSORIES B0900 B0899 B0906 B0907 B0915 01804 01805 01806 01200 B0618 B0666 B0617 Cable for Modbus connection touch panel 100m Metallic frame for touch panel external installation Aesthetic fan cover front grille Aesthetic fan cover front grille Brass Y filter HE 200 L storage tank HE 300 L storage tank HES 300 L solar storage tank Thermal accumulation 100 L Resistance for boiler 2 kW Resistance for boiler 3 kW Resistance flange kit 10 15 10 15T 10 Standard accessory | Optional accessory | Required accessory | Accessory not compatible Accessory description on page 54 Please note that optional accessories are available for purchase with all models of the heat pump. When compatibility is only possible with certain sizes, the information is shown in the table. Standard accessories are already included in the heat pump code. Catalogue 2024 | January edition 45 PORTABLES SHERPA MONOBLOC S2 Monobloc heat pump Compatible with: COMPACT TECHNOLOGY Compact unit and reduced dimensions. For all power sizes the machine is equipped with a single fan unit. DOMESTIC HOT WATER UP TO 60°C Sherpa supplies Domestic Hot Water with temperatures up to 60°C. INTEGRATED WI-FI By downloading the Comfort Home app you can manage all its features from your smartphone, even when away from home. FEATURES · Air-water heat pump inverter with R32 refrigerant · Energy efficiency class in heating moderate climate: A+++ (35°C) e A++ (55°C) · Power available: 9 versions with R32 refrigerant single-phase (6-8-10-12-14-16 kW) three-phase power supplies (12-14-16 kW) · DHW production: up to 60°C · Compressor: twin rotary DC. · Expansion valve: electronic. · Fan with brushless DC motor. · Standard supply remote touchscreen control panel (connection cable up to 50 m not included). Integrated Wi-Fi module for controlling the machine via smartphone and table, with relevant app (Comfort Home) · Refrigerant gas: R32* · Operating limits: up to -25°C, +43°C (see technical manuals for details) · External air probe integrated in the machine. · Domestic Hot Water storage tank probe: standard supply with the machine. · Cascade management: up to 6 units can be connected (of the same size), 1 Master and 5 Slaves (only the Master unit can produce domestic hot water). · Smart Grid: the heat pump is prepared to dialogue with a smart electric grid and is SG Ready certified, according to the requirements of the German BWP Institute. * Equipment hermetically sealed containing fluorinated gases with an equivalent GWP of 675 (R32) 46 BMS LAYOUT, DIMENSIONS, WEIGHT 6 8 10 12 14 16 12T 14T 16T MONOFAN A mm 1040 1040 1040 1040 1040 1040 1040 1040 1040 B mm 410 410 410 410 410 410 410 410 410 C mm 458 458 458 458 458 458 458 458 458 D mm 523 523 523 523 523 523 523 523 523 E mm 191 191 191 191 191 191 191 191 191 F mm 656 656 656 656 656 656 656 656 656 G mm 64 64 64 64 64 64 64 64 64 H mm 865 865 865 865 865 865 865 865 865 I mm 165 165 165 165 165 165 165 165 165 J mm 279 279 279 279 279 279 279 279 279 K mm 89 89 89 89 89 89 89 89 89 Weight kg 87 87 87 106 106 106 120 120 120 HEAT PUMPS FAN COIL UNITS HRV UNICO CASCADING Cascading of up to 6 units. System power up to 96 kW. REMOTE CONTROL VIA APP COMFORT HOME The heat pump can be controlled remotely with Tablet and Smartphone thanks to the standard Wi-Fi module (to be interfaced with a wireless router connected to the Internet). The "Comfort Home" App can be downloaded free of charge from the Google and Apple Stores, which allows control of the machine via the Cloud. Catalogue 2024 | January edition 47 MONO AND MULTISPLIT PORTABLES PUNCTUAL PERFORMANCE EFFICIENCIES TECHNICAL DATA Sherpa Monobloc S2 E Compressor frequency Heating power COP Heating power COP Heating power COP Heating power COP Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Cooling power EER Cooling power (fancoils) EER (fancoils) Energy efficiency class in water heating 35°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C SCOP s (Seasonal efficiency for space heating) Indoor unit sound power Indoor unit sound pressure Outdoor unit sound power (nominal) Outdoor unit sound pressure (nominal) System circulator absorption Supply voltage indoor unit Maximum absorbed current of the internal unit with active heating elements Internal unit maximum power consumption with active heating elements Additional electric heating elements Supply voltage outdoor unit Outdoor unit maximum absorbed current Outdoor unit maximum absorbed power Compressor type Refrigerant inlet connection diameter Coolant gas Global warming potential Refrigerant gas charge Refrigerant piping length limit without minimum surface check according to IEC 60335-2-40:2018 Hydraulic connections Capacity of expansion vessel 6 8 10 12 14 16 02303 02304 02305 02306 02307 02308 Min Nom Max Min Nom Max Min Nom Max Min Nom Max Min Nom Max Min Nom Max a7/6 - w30/35 (a) kW - 6,5 8,47 - 8,4 9,56 - 10 11,16 - 12,2 13,42 - 14,1 15,27 - 16 18,23 a7/6 - w30/35 (a) W/W - 5,3 - - 5,05 - - 4,7 - - 4,9 - - 4,7 - - 4,5 - a2/1 - w30/35 (b) kW - 5,6 7,64 - 7,1 8,52 - 8,2 9,94 - 12,3 12,3 - 13 13,56 - 14,5 14,76 a2/1 - w30/35 (b) W/W - 4,2 - - 3,95 - - 3,8 - - 3,6 - - 3,5 - - 3,25 - a-7/-8 - w30/35 (c) kW - 6,2 6,67 - 7,1 7,65 - 8 8,4 - 11,6 12,1 - 12,5 13,2 - 13,5 14,1 a-7/-8 - w30/35 (c) W/W - 3,2 - - 3,15 - - 3 - - 2,85 - - 2,8 - - 2,7 - a-15/-16 - w30/35 (d) kW - 5,59 5,59 - 6,07 6,07 - 6,48 6,48 - 10,35 10,35 - 11,22 11,22 - 11,82 11,82 a-15/-16 - w30/35 (d) W/W - 2,58 - - 2,54 - - 2,5 - - 2,39 - - 2,35 - - 2,22 - a7/6 - w40/45 (f) kW - 6,6 8,14 - 8,5 9,28 - 10,2 10,87 - 12,5 13,14 - 14,5 14,87 - 16,2 18,07 a7/6 - w40/45 (f) W/W - 4 - - 3,8 - - 3,65 - - 3,7 - - 3,55 - - 3,45 - a2/1 - w40/45 (g) kW - 6,5 7,03 - 7,5 8,22 - 8,5 9,42 - 12 12 - 13 13,28 - 14,3 14,74 a2/1 - w40/45 (g) W/W - 3,15 - - 3,05 - - 2,95 - - 2,9 - - 2,8 - - 2,7 - a-7/-8 - w40/45 (h) kW - 6,1 6,47 - 6,8 7,43 - 7,4 8,16 - 11,5 11,5 - 12,5 12,5 - 13,5 13,5 a-7/-8 - w40/45 (h) W/W - 2,6 - - 2,5 - - 2,4 - - 2,4 - - 2,3 - - 2,25 - a-15/-16 - w40/45 (i) kW - 5,45 5,45 - 5,92 5,92 - 6,33 6,33 - 9,62 9,62 - 10,3 10,3 - 10,96 10,96 a-15/-16 - w40/45 (i) W/W - 2,23 - - 2,2 - - 2,14 - - 2,11 - - 2,07 - - 1,98 - a35 - w23/18 (l) kW - 6,5 9,27 - 8,3 10,31 - 10 10,31 - 12,2 16,11 - 13,9 17,13 - 15,4 17,13 a35 - w23/18 (l) W/W - 5,1 - - 4,85 - - 4,3 - - 4,6 - - 4,4 - - 4,2 - a35 - w12/7 (m) kW - 5,5 6,84 - 7,4 8,66 - 9 9 - 11,6 13,44 - 13,4 15,48 - 14 16,01 a35 - w12/7 (m) W/W - 3,25 - - 3,15 - - 2,9 - - 3,1 - - 2,93 - - 2,9 - Warmer Climate Warmer Climate 6,78 6,94 7,05 6,63 6,59 6,46 Warmer Climate s % 268,2 274,7 279,1 262,3 260,5 255,4 Average Climate Average Climate 5,12 5,17 5,12 5,08 4,89 4,84 Average Climate s % 201,8 204 201,9 200,1 192,5 190,5 Cold Climate Cold Climate 4,41 4,44 4,44 4,3 4,36 4,35 Cold Climate s % 173,4 174,6 174,6 168,8 171,3 170,9 Warmer Climate Warmer Climate 4,35 4,71 4,91 4,55 4,69 4,68 Warmer Climate s % 170,9 185,3 193,4 179 184,6 184 Average Climate Average Climate 3,59 3,67 3,71 3,62 3,62 3,59 Average Climate s % 140,7 143,6 145,5 141.6 141,8 140,6 Cold Climate Cold Climate 2,9 3,02 3,14 3,23 3,24 3,18 Cold Climate s % 113,1 117,7 122,4 126 126,6 124,3 dB(A) - - - - - - (n) dB(A) - - - - - - dB(A) 60 63 65 70 72 72 (o) dB(A) 48 51 53 56 58 58 W 4-95 4-95 4-95 4-95 4-95 4-95 V/ph/Hz - - - - - - A - - - - - - kW kW V/ph/Hz A kW " (p) GWP kg (q) - 220-240/1/50 13 3,2 TWIN ROTARY R32 675 1,25 - - 220-240/1/50 14,5 3,5 TWIN ROTARY R32 675 1,25 - - 220-240/1/50 16 3,8 TWIN ROTARY R32 675 1,25 - - 220-240/1/50 25 5,8 TWIN ROTARY R32 675 1,8 - - 220-240/1/50 26,5 6,2 TWIN ROTARY R32 675 1,8 - - 220-240/1/50 28 6,6 TWIN ROTARY R32 675 1,8 - " G1 BSP G1 BSP G1 BSP G5/4 BSP G5/4 BSP G5/4 BSP l 5 5 5 5 5 5 NOISE LEVEL ELECTRICAL DATA COOLING CIRCUIT HYDRAULIC DATA (a) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 30°C/35°C (b) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 30°C/35°C (c) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 30°C/35°C (d) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 30°C/35°C (f) Heating mode, external air temperature 7°C b.s./6°C b.u., inlet/outlet water temperature 40°C/45°C (g) Heating mode, external air temperature 2°C b.s./1°C b.u., inlet/outlet water temperature 40°C/45°C (h) Heating mode, external air temperature -7°C b.s./-8°C b.u., inlet/outlet water temperature 40°C/45°C (i) Heating mode, external air temperature -15°C b.s./-16°C b.u., inlet/outlet water temperature 40°C/45°C (l) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 23°C/18°C 48 (m) Cooling mode, external air temperature 35°C, inlet/outlet water temperature 12°C/7°C (n) Sound pressure values measured at a distance of 1 m in a semi-anechoic chamber (o) Sound pressure values measured at a distance of 1 m in a semi-anechoic chamber (p) Airtightally sealed equipment containing fluorinated GAS (q) maximum length of the refrigeration pipes beyond which checks on the minimum surface of the installation rooms are necessary, check the technical manual Catalogue 2024 | January edition BMS PUNCTUAL PERFORMANCE HEAT PUMPS FAN COIL UNITS EFFICIENCIES TECHNICAL DATA Sherpa Monobloc S2 E Compressor frequency Heating power COP Heating power COP Heating power COP Heating power COP Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Heating power (fancoils) COP (fancoils) Cooling power EER Cooling power (fancoils) EER (fancoils) Energy efficiency class in water heating 35°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 35°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C SCOP s (Seasonal efficiency for space heating) Energy efficiency class in water heating 55°C SCOP s (Seasonal efficiency for space heating) Indoor unit sound power Indoor unit sound pressure Outdoor unit sound power (nominal) Outdoor unit sound pressure (nominal) System circulator absorption Supply voltage indoor unit Maximum absorbed current of the internal unit with active heating elements Internal unit maximum power consumption with active heating elements Additional electric heating elements Supply voltage outdoor unit Outdoor unit maximum absorbed current Outdoor unit maximum absorbed power Compressor type Refrigerant inlet connection diameter Coolant gas Global warming potential Refrigerant gas charge Refrigerant piping length limit without minimum surface check according to IEC 60335-2-40:2018 Hydraulic connections Capacity of expansion vessel a7/6 - w30/35 (a) kW a7/6 - w30/35 (a) W/W a2/1 - w30/35 (b) kW a2/1 - w30/35 (b) W/W a-7/-8 - w30/35 (c) kW a-7/-8 - w30/35 (c) W/W a-15/-16 - w30/35 (d) kW a-15/-16 - w30/35 (d) W/W a7/6 - w40/45 (f) kW a7/6 - w40/45 (f) W/W a2/1 - w40/45 (g) kW a2/1 - w40/45 (g) W/W a-7/-8 - w40/45 (h) kW a-7/-8 - w40/45 (h) W/W a-15/-16 - w40/45 (i) kW a-15/-16 - w40/45 (i) W/W a35 - w23/18 (l) kW a35 - w23/18 (l) W/W a35 - w12/7 (m) kW a35 - w12/7 (m) W/W Warmer Climate Warmer Climate Warmer Climate s % Average Climate Average Climate Average Climate s % Cold Climate Cold Climate Cold Climate s % Warmer Climate Warmer Climate Warmer Climate s % Average Climate Average Climate Average Climate s % Cold Climate Cold Climate Cold Climate s % dB(A) (n) dB(A) dB(A) (o) dB(A) W V/ph/Hz A kW kW V/ph/Hz A kW " (p) GWP kg (q) " l 12T 02309 Min Nom Max - 12,2 13,42 - 4,9 - - 12,3 12,3 - 3,6 - - 11,6 12,1 - 2,85 - - 10,35 10,35 - 2,39 - - 12,5 13,14 - 3,7 - - 12 12 - 2,9 - - 11,5 11,5 - 2,4 - - 9,62 9,62 - 2,11 - - 12.2 16.11 - 4,6 - - 11,6 13,44 - 3,1 - 6,64 262,5 5,08 200,2 4,3 168,8 4,55 179 3,62 141,6 3,23 126 70 57 4-95 - - - 380-415/3/50 9,5 5,8 TWIN ROTARY R32 675 1,8 - G5/4 BSP 5 14T 02310 Min Nom Max - 14,1 15,27 - 4,7 - - 13 13,56 - 3,5 - - 12,5 13,2 - 2,8 - - 11,22 11,22 - 2,35 - - 14,5 14,87 - 3,55 - - 13 13,28 - 2,8 - - 12,5 12,5 - 2,3 - - 10,3 10,3 - 2,07 - - 13,9 17,13 - 4,4 - - 13,4 15,48 - 2,93 - 6,59 260,6 4,89 192,5 4,36 171,3 4,69 184,6 3,62 141,8 3,24 126,6 72 59 4-95 - - - 380-415/3/50 10,5 6,2 TWIN ROTARY R32 675 1,8 - G5/4 BSP 5 16T 02311 Min Nom Max - 16 18,23 - 4,5 - - 14,5 14,76 - 3,25 - - 13,5 14,1 - 2,7 - - 11,82 11,82 - 2,22 - - 16,2 18,07 - 3,45 - - 14,3 14,74 - 2,7 - - 13,5 13,5 - 2,25 - - 10,96 10,96 - 1,98 - - 15,4 17,13 - 4,2 - - 14 16,01 - 2,9 - 6,46 255,5 4,84 190,5 4,35 170,9 4,68 184 3,59 140,7 3,18 124,3 72 59 4-95 - - - 380-415/3/50 11,5 6,6 TWIN ROTARY R32 675 1,8 - G5/4 BSP 5 HRV NOISE LEVEL ELECTRICAL DATA UNICO COOLING CIRCUIT HYDRAULIC DATA MONO AND MULTISPLIT ACCESSORIES STORAGE TANKS / PUFFER B0916 01804 01805 01806 01807 01808 B0618 B0666 B0617 01199 01200 Kit 3-way valve for DHW HE 200 L storage tank HE 300 L storage tank HES 300 L solar storage tank Hybride boiler HY 300 L HYS 300 L solar hybrid storage tank Resistance for boiler 2 kW Resistance for boiler 3 kW Resistance flange kit Thermal accumulation 50 L Thermal accumulation 100 L Optional accessory | Standard accessory | Accessory not compatible Accessory description on page 54 Please note that optional accessories are available for purchase with all models of the heat pump. When compatibility is only possible with certain sizes, the information is shown in the table. Standard accessories are already included in the heat pump code. Catalogue 2024 | January edition 49 PORTABLES SHERPA SHW S2 Water heater in heat pump HIGH EFFICIENCY Sherpa SHW S2 achieves the highest energy class in its category (according to the ErP regulation). PHOTOVOLTAIC INTEGRATION Contact for integration with photovoltaic plant, which forces switch-on and raises the machine set-point. Th e energy produced by the photovoltaic system is stored to lower the DHW production costs and maximise the energy saving. SOLAR MANAGEMENT Solar thermal compatible: the unit can work with a second energy source such as solar panels (solar circulator management). Valid only for model 360S. FEATURES · Available in two versions: standard model with heat pump, electric heating element and 202-litre tank (Sherpa SHW S2 200); model with coil for solar panels or other energy sources, electric heating element and 251-litre tank (Sherpa SHW S2 260S). · COP>2,6* DHW at 65°C (75°C with electric heating element) · Energy class: A+ · Working range with heat pump and air temperature from -10C° to 43C°. · Enamelled steel tank. · Anti-corrosion magnesium anode to ensure tank durability. · Condenser wound outside the boiler free from deposits and gas-water contamination. · Rigid polyurethane foam (PU) thermal insulation, thickness 50mm. · External plastic cladding. Soundproof plastic top cover. · High-efficiency compressor with R134a refrigerant**. · Electric heating element available in the unit as back-up which ensures hot water at a constant temperature even in extreme winter or summer conditions. · ON-OFF contact to start the unit via an external switch. · Weekly sanitisation cycle. · Option to manage the domestic hot water recirculation or solar heating integration. Valid only for model 260S · Electronic expansion valve for a timely check. * Ambient air temperature 7°C b.s./6°C b.u., water temperature from 10°C to 55°C (EN 16147). ** hermetically sealed equipment containing fluorinated gas with GWP equivalent 1430. 50 BMS HEAT PUMPS FAN COIL UNITS 200 h mm 1720 a mm 994 b mm 724 d mm 995 f mm 803 i mm - k mm 60 n mm - u mm 1153 w mm 58 M mm 260 ØDF mm 160 R mm 1785 ØD mm 630 260S 2010 1285 834 1285 1064 781 60 766 1440 58 260 160 2055 630 CW - Cold water inlet G 1" HW - Hot water outlet G 1" IS - Heat exchanger inlet G 1" OS - Heat exchanger outlet G 1" R - Recirculation G ¾" TS - Temperature probe G ½" EE - Opening for electric heating element G 1 ½" CD - Condensation drain G ¾" 9. 1'' Solar energy return 10. 1'' domestic cold water inlet 11. Condensation drain Ø 16 TECHNICAL DATA Electrical power supply Actual tank capacity Prated nominal heating power (EN 16147: 2017 - A7/W55) Maximum heating power (summer conditions) COPDHW (EN 16147: 2017 - A7/W55) COPDHW (EN 16147: 2017 - A14/W55) Maximum electrical absorption with active electric heating element Heating time (EN 16147: 2017 - A7/W55) Heating time in BOOST mode (A7 - W10-55) Intake air temperature range Refrigerant gas (a) Refrigerant loading Nominal air flow rate (98 Pa) Storage tank maximum operating pressure Auxiliary electric heating element Solar exchange coil surface Protection class Transportation weight Sound pressure (EN 12102:2013) Load Profile (EN 16147: 2017) Energy efficiency class (average climate conditions) WH (average climate conditions - EU Regulation 812/2013) (a) hermetically sealed equipment containing fluorinated gas with GWP equivalent 1430. V/Ph/Hz L W W W/W W/W W h:min h:min °C g m3/h bar W m² Kg dB(A) % SHERPA SHW S2 200 02385 220-240/1Ph+N/50 202 1050 2305 2.7 3.1 663+1500 08:59 03:47 -10 ÷ 43 R134a 880 315 8 1500 IPX4 105 53 L 118 SHERPA SHW S2 260S 02386 220-240/1Ph+N/50 251 1200 2305 3 3.4 663+1500 10:15 04:21 -10 ÷ 43 R134a 880 315 8 1500 1.2 IPX4 128 53 XL 124 HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 51 Heat pump accessories Download Additional information on these accessories B0931 Remote control display kit 10 m Remote control display kit 10 m Compatible with: SHERPA AQUADUE suspended tower SHERPA B0916 Kit 3-way valve for DHW Compact size and two-point control. suspended tower Compatible with: suspended tower SHERPA AQUADUE SHERPA MONOBLOC SHERPA B0917 Solar thermal probe kit Additional probe that detects the temperature of the solar thermal pipes, inhibits the heat pump from producing DHW only with solar thermal under certain conditions. Compatible with: SHERPA suspended tower B0623 Outdoor air temperature probe kit Shielded probe to measure the outdoor air temperature. It is necessary to allow activation of the electric heating element and climatic curves. Compatible with: SHERPA AQUADUE SHERPA suspended tower B0624 Kit DHW storage tank sensor Probe to measure and directly control the water temperature in the domestic hot water storage tank. Compatible with: SHERPA AQUADUE SHERPA suspended tower Standard accessory | Optional accessory | Required accessory | Accessory not compatible Please note that optional accessories are available for purchase with all models of the heat pump. When compatibility is only possible with certain sizes, the information is shown in the table. Standard accessories are already included in the heat pump code. 52 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV B0918 Kit Sherpa Flex Box AS Technical cabinet that makes it possible to create a compact system in heat pump with high installation flexibility. B0961 Compatible with: SHERPA AQUADUE suspended tower 10 SHERPA suspended tower 10 Kit Sherpa Flex Box AS RAL 9016 Technical cabinet that makes it possible to create a compact system in a heat pump with high installation flexibility. Painted in white RAL 9016 (front/back for upper, lower side and front panels, no backs). NEW B1120 Compatible with: SHERPA AQUADUE suspended tower 10 SHERPA suspended tower 10 Sherpa Flex Box adapter kit Accessory necessary for combining the Sherpa Flex Box AS Kit with the Sherpa S2/S3 heat pump (not Aquadue). B0900 Compatible with: SHERPA suspended tower 10 Cable for Modbus connection touch panel 100m Length 100 m. Required accessory supplied separately. B0899 Compatible with: SHERPA COLD Metallic frame for touch panel external installation Compatible with: SHERPA COLD B0906 Aesthetic fan cover front grille Compatible with: SHERPA COLD 10 B0907 Aesthetic fan cover front grille B0915 B0971 B0972 Compatible with: SHERPA COLD 15 Brass Y filter With 1" 1/4 couplers and 2" body Compatible with: SHERPA COLD Thermostatic mixing valve kit for DHW Assembly in the machine must be carried out by the installer Compatible with: SHERPA suspended tower Expansion tank kit for DHW Assembly in the machine must be carried out by the installer Compatible with: SHERPA suspended tower UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 53 Storage tanks / puffer 01804 HE 200 L storage tank Compatible with: suspended tower SHERPA AQUADUE SHERPA COLD 10 SHERPA SHERPA MONOBLOC 01805 HE 300 L storage tank Compatible with: suspended tower SHERPA AQUADUE SHERPA COLD SHERPA SHERPA MONOBLOC 01806 HES 300 L solar storage tank Compatible with: suspended tower SHERPA AQUADUE SHERPA SHERPA COLD SHERPA MONOBLOC 15T Storage tank with 1 or 2 coils with high exchange surface in carbon steel, complete with anodic protection, internal vitrification treatment according to DIN 4753-3 and UNI 10025 standards. Rigid polyurethane insulation thickness 70 mm. Coating colour Sky Blue RAL 5010. TECHNICAL DATA Inhoud boiler HWW Nom. Inhoud boiler HWW Effective Total heigh Diameter with insulation Insulation Energy class Dispersion total Dispersion temperature probe Coil exchangers N° Coil exchangers Surface Heat pump Coil exchangers Secondary surface Empty weight 01804 01805 01806 l 200 300 300 l 190 263 260 mm 1215 1615 1615 mm 640 640 640 mm 70 70 70 B B B W 51 63 63 W/°K 1,13 1,40 1,40 1 double coil 1 double coil 1 double coil + 1 solar unit m² 3 4 3,7 m² - - 1,2 kg 90 124 131 Dimensions A mm B mm C mm D mm E mm F mm G mm H mm I mm J mm K mm L mm M mm 01804 500 995 735 320 140 220 370 835 990 1070 1215 - 01805 500 1390 945 340 140 220 395 1165 1310 1390 1615 - 01806 500 1470 1035 590 315 140 220 495 650 865 1390 1470 1615 Storage tank 1 coil HE 200-300 Storage tank 2 coils HES 300 1. Hot water flow 1" 2. Anode 1" 1/4 3. Thermometer-Probe 1/2" 4. Electric heating element attachment 1" 1/2 5. Pallet attachment (blind) 1/2" 6. Cold water inlet 1" 7. Coil return 1" 8. Thermostat 1/2" 9. Recirculation 1/2" 10.Coil flow 1" Optional accessory | Accessory not compatible 1. Anode 1" 1/4 2. Thermometer-Probe 1/2" 3. Thermostat 1/2" 4. Thermostat 1/2" 5. Pallet attachment (blind) 1/2" 6. Cold water inlet 1" 7. Lower coil return 1" 8. Lower coil flow 1" 9. Upper coil return 1" 10.Recirculation 1/2" 11. Upper coil flow 1" 12. Hot water flow 1" 13. Flange with electric heating element attachment 1" 1/2 Please note that optional accessories are available for purchase with all models of the heat pump. When compatibility is only possible with certain sizes, the information is shown in the table. Standard accessories are already included in the heat pump code. 54 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS 01807 Hybride boiler HY 300 L Compatible with: suspended tower SHERPA AQUADUE SHERPA MONOBLOC SHERPA 01808 HYS 300 L solar hybrid storage tank Compatible with: suspended tower SHERPA AQUADUE SHERPA MONOBLOC SHERPA Combined heat storage tanks. Upper storage tank with 1 or 2 coils with high exchange surface in carbon steel, complete with anodic protection, internal vitrification treatment according to DIN 4753-3 and UNI 10025 standards. Lower storage tanks for heated or chilled water, internal untreated. Rigid polyurethane insulation thickness 70 mm. Coating colour Sky Blue RAL 5010. TECHNICAL DATA 01807 Inhoud boiler HWW Nom. l 300 Inhoud boiler HWW Effective l 270 Puffer Capacity l 80 Total heigh mm 1925 Diameter with insulation mm 690 Insulation mm 70 Energy class B Dispersion total W 73 Dispersion temperature probe W/°K 1,62 Coil exchangers N° 1 Coil exchangers Surface Heat pump m² 3,3 Coil exchangers Secondary surface m² - Empty weight kg 150 01808 300 270 80 1925 690 70 B 73 1,62 1 + 1 solar unit 2,8 0,9 170 Dimensions A B C D E F G H I J K L M N O P Q R S 01807 mm 550 mm 1755 mm 1300 mm 875 mm 340 mm 160 mm 160 mm 340 mm - mm 675 mm 765 mm 940 mm 1425 mm 1675 mm 1755 mm 1925 mm 150 mm - mm - 01808 550 1755 1420 1035 810 340 160 160 340 675 755 945 1125 1280 1675 1755 1925 150 HRV UNICO MONO AND MULTISPLIT Storage tank 1 coil HY 300 1. Domestic hot water flow 1" 2. Anode 1" 1/4 3. Thermometer 1/2" 4. Electric heating element attachment 1" 1/2 6. Probe 1/2" 7. Boiler flow 1" 8. Boiler return 1" 9. Electric resistance 1" 1/2 10.Heating system return 1" 11. System flow 1" 12. Domestic cold water inlet 1" 13. Coil return 1" 1/4 14. Probe 1/2" 16. Recirculation 1/2" 17. Upper coil flow 1" Catalogue 2024 | January edition Storage tank 2 coils HYS 300 1. Domestic hot water flow 1" 2. Anode 1" 1/4 3. Thermometer 1/2" 4. Probe 1/2" 5. Probe 1/2" 6. Probe 1/2" 7. Boiler flow 1" 8. Boiler return 1" 9. Electric resistance 1" 1/2 10.Heating system return 1" 11. System flow 1" 12. Domestic cold water inlet 1" 13. Lower coil return 1" 14. Lower coil flow 1" 15. Upper coil return 1" 16. Recirculation 1/2" 17. Upper coil flow 1" 55 PORTABLES 01199 Thermal accumulation 50 L Compatible with: suspended tower SHERPA SHERPA MONOBLOC SHERPA AQUADUE 01200 Thermal accumulation 100 L Compatible with: suspended tower SHERPA SHERPA COLD 10 SHERPA AQUADUE SHERPA MONOBLOC Storage for chilled water, internal untreated. Can also be used for heating water. Polyurethane insulation 50 mm. Coating colour Sky Blue RAL 5010. TECHNICAL DATA Puffer Capacity Total heigh Diameter with insulation Insulation Energy class Dispersion total Dispersion temperature probe Empty weight 01199 l 57 mm 935 mm 400 mm 50 B W 34 W/°K 0,76 kg 25 01200 123 1095 500 50 B 50 1,11 35 Dimensions A B C D E F G 01199 mm 300 mm 100 mm 180 mm 485 mm 530 mm 785 mm 935 01200 400 100 185 560 605 935 1095 1. Vent 1" 2. Water connection 1" 1/4 4. Water connection 1" 1/4 6. Probe 1/2" 7. Probe 1/2" 12. Electric resistance 1" 1/2 13. Drain 1/2" B0618 Resistance for boiler 2 kW Compatible with: suspended tower SHERPA SHERPA COLD SHERPA MONOBLOC B0666 Resistance for boiler 3 kW Compatible with: suspended tower SHERPA SHERPA COLD SHERPA MONOBLOC Immersion in copper, IP 65, with internal adjustable thermostat and temperature limiter. TECHNICAL DATA Absorbed power Supply voltage Weight Lenght (L) Diameter of coupling B0618 W 2000 V 230 Kg 1,5 mm 390 inch 1"1/2 B0666 3000 230 1,5 390 1"1/2 Optional accessory | Accessory not compatible Please note that optional accessories are available for purchase with all models of the heat pump. When compatibility is only possible with certain sizes, the information is shown in the table. Standard accessories are already included in the heat pump code. 56 Catalogue 2024 | January edition BMS B0617 Resistance flange kit Required accessory for correct positioning of the electric heating elements when used for anti-Legionnaires disease cycles. Compatible with: suspended tower SHERPA SHERPA COLD SHERPA MONOBLOC HEAT PUMPS FAN COIL UNITS HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 57 System diagrams Sherpa Aquadue heat pumps SHERPA AQUADUE S2/S3 heat pump (heating and air conditioning; production of high temperature DHW); Bi2 SLR radiant fan coil units; example of a two-zone configuration with a simple manifold and integrated inertial storage (used as a hydraulic separator) for the air conditioning system. Schematic diagram, refer to the installation manual. In particular, the water filtration and treatment system is not shown. SHERPA AQUADUE TOWER S2/S3 heat pump (heating and air conditioning; production of high temperature DHW); Bi2 SLR radiant fan coil units; example of a two-zone configuration with a simple manifold and inertial storage (used as a hydraulic separator) for the air conditioning system. Schematic diagram, refer to the installation manual. In particular, the water filtration and treatment system is not shown. 58 Catalogue 2024 | January edition BMS Sherpa heat pumps SHERPA S2/S3 heat pump (heating and air conditioning; DHW production) Bi2 SLR radiant fan coil units; domestic water integration with solar thermal and integrated inertial storage (used as hydraulic separator) for the air conditioning system. HEAT PUMPS FAN COIL UNITS HRV Schematic diagram, refer to the installation manual. In particular, the water filtration and treatment system is not shown. SHERPA TOWER S2/S3 heat pump (heating and air conditioning; DHW production) Bi2 SLR radiant fan coil units with 3-way valves and inertial storage in series on the return pipe of the air conditioning system. UNICO MONO AND MULTISPLIT PORTABLES Schematic diagram, refer to the installation manual. In particular, the water filtration and treatment system is not shown. N.B. Sherpa Tower S3E indoor unit with thermostatic mixer kit (B0971) and expansion tank kit for DHW (B0972). Catalogue 2024 | January edition 59 Kit Sherpa Flex Box SHERPA AQUADUE S3 E heat pump or SHERPA S3 E with SHERPA FLEX BOX AS KIT (heating and air conditioning; production of high temperature DHW); Bi2 SLR radiant fan coil units with 3-way valves. Schematic diagram, refer to the installation manual. In particular, the water filtration and treatment system is not shown. Maximum domestic cold water inlet pressure 3.0 bar. Sherpa Cold heat pumps SHERPA COLD heat pump (heating and air conditioning; production of DHW) Bi2 SLR radiant fan coil units with 3-way valves and inertial storage tank (used as hydraulic separator). Storage of technical water with instant DHW production. It is mandatory to provide safety valves and appropriately sized expansion tanks outside the heat pump. Schematic diagram, refer to the installation manual. In particular, the water filtration and treatment system is not shown. 60 Catalogue 2024 | January edition BMS Sherpa Monobloc heat pumps SHERPA MONOBLOC S2 E heat pump (heating and air conditioning) Bi2 SLR radiant fan coil units with 3-way valves and inertial storage in series on the return pipe of the air conditioning system. HEAT PUMPS FAN COIL UNITS HRV Schematic diagram, refer to the installation manual. In particular, the water filtration and treatment system is not shown. SHERPA MONOBLOC S2 E heat pump (heating and air conditioning; DHW production) Bi2 SLR radiant fan coil units, domestic water integration with solar thermal and integrated inertial storage (used as hydraulic separator) for the air conditioning system. UNICO MONO AND MULTISPLIT PORTABLES Schematic diagram, refer to the installation manual. In particular, the water filtration and treatment system is not shown. Catalogue 2024 | January edition 61 Olimpia Splendid partecipates in the ECP programme for FCU. Check ongoing validity of certificate: www.eurovent-certification.com Bi2 Hydronic system terminal units for annual cycle comfort Italian design winner of numerous international awards Ultraslim and slim innovation Attention to design and harmonious integration into the architecture has led Olimpia Splendid to reinvent fan coil units, introducing ultraslim (up to 12.9 cm) and slim (up to 17.9 cm) fan coils with reduced thicknesses to the market. Design signed by Italian studios The Bi2 fan coil units boast prestigious names in the world of Italian industrial design. Each product is in fact designed with particular attention to architectural integration and ease of installation, management and maintenance. Olimpia Splendid has won 7 international awards for the aesthetics of its fan coil units, from 2013 to today. Made in Italy quality Olimpia Splendid production is within its headquarters in Cellatica (BS). The typically Italian attention to detail is a further guarantee of product quality. 64 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV UNICO Innovative solutions to rethink the fan coil units Olimpia Splendid radiant technology The Bi2 fan coil units are also available in the radiant version, with a tubular heating panel, in addition to the coil, which stands out for its superior performance compared to other systems with radiant technology on the market: - higher radiated power, thanks to the higher average surface temperature; - amplification of natural convection; - possibility of static operation (fan off) for the complete absence of noise. Comfort and optimised running costs The slim and ultraslim radiant fan coil units offer comfort at least equal to that of floor heating, with greater flexibility, lower installation costs and more economical running, especially in warmer climates. The data shown in the graph refer to a comparative study commissioned by Olimpia Splendid to evaluate the different performances of a system, depending on whether the radiant fan coil units are used rather than the floor heating. MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 65 Installation The choice of position The Bi2 fan coil units are extremely versatile and can be installed both on the floor and on a low wall. The SL models, with traditional convection technology, are also suitable for ceiling installation, while the ultraslim SLW solutions are easily placed on high or low walls, with a considerably reduced footprint, thanks to the console format. Please note: for all models, if wall-mounted thermostats are not used, the installation of 2- or 3-way valves is recommended for optimal cooling operation. Operation The modes for providing comfort The structure of the fan of the Bi2 fan coil units and the electric motor that modulates its speed ensure even air distribution and homogeneity of temperature in the environment. The entire range has two operating modes: heating and cooling, with forced convection. In the SLR models, with Olimpia Splendid radiant technology, the heating mode also works in static mode (fan off), with natural convection and radiation from the front panel, for maximum acoustic comfort. Maintenance How to clean the fan coil unit The easily removable air filters make cleaning and maintenance of the fan coil unit particularly easy, even in the built-in models. 66 67 PORTABLES MONO AND MULTISPLIT UNICO HRV FAN COIL UNITS HEAT PUMPS BMS System terminal units Console FCU - brushless DC motors Bi2 AIR Integral design, motorised flap and integrated control. SLR VERSION SL VERSION ULTRASLIM DESIGN 200 400 600 SLR AIR 200 DC TR (01856) SLR AIR 200 DC AR (01772) SL AIR 200 DC TR (01851) SL AIR 200 DC AR (01767) 12,9 cm SLR AIR 400 DC TR (01857) SLR AIR 400 DC AR (01773) SL AIR 400 DC TR (01852) SL AIR 400 DC AR (01768) 12,9 cm SLR AIR 600 DC TR (01858) SLR AIR 600 DC AR (01774) SL AIR 600 DC TR (01853) SL AIR 600 DC AR (01769) 12,9 cm Bi2 SMART Total flat design. SLR VERSION SL VERSION SLR SMART S1 200 B DC (02127) SLR SMART S1 400 B DC (02128) SLR SMART S1 600 B DC (02129) SL SMART S1 200 B DC (02122) SL SMART S1 400 B DC (02123) SL SMART S1 600 B DC (02124) 12,9 cm 12,9 cm 12,9 cm Bi2 NAKED Built-in SLIR VERSION SLI VERSION SLIR 200 DC (01639) SLI 200 DC (01513) 14,2 cm SLIR 400 DC (01640) SLI 400 DC (01514) 14,2 cm SLIR 600 DC (01641) SLI 600 DC (01515) 14,2 cm High-wall FCU - brushless DC motors Bi2 WALL motorised flap and integrated control. 2-WAY VERSION 3-WAY VERSION ULTRASLIM DESIGN REVERSIBILE 400 SLW 400 DC V2V TR (01784) SLW 400 DC V2V AR (01875) SLW 400 DC V3V TR (01787) SLW 400 DC V3V AR (01878) 12,9 cm Ci2 WALL Motorised flap 600 SLW 600 DC V2V TR (01785) SLW 600 DC V2V AR (01876) SLW 600 DC V3V TR (01788) SLW 600 DC V3V AR (01879) 12,9 cm 68 Catalogue 2024 | January edition BMS HEAT PUMPS SLIM DESIGN 800 1000 1100 SLR AIR 800 DC TR (01859) SLR AIR 800 DC AR (01775) SL AIR 800 DC TR (01854) SL AIR 800 DC AR (01770) 12,9 cm OUT SLR AIR 1000 DC TR (01860) OUT SLR AIR 1000 DC AR (01776) OUT SL AIR 1000 DC TR (01855) OUT SL AIR 1000 DC AR (01771) 12,9 cm SLR AIR 1100 DC TR (02360) SLR AIR 1100 DC AR (02359) SL AIR 1100 DC TR (02362) SL AIR 1100 DC AR (02361) 17,9 cm 1400 SLR AIR 1400 DC TR (02052) SLR AIR 1400 DC AR (02053) SL AIR 1400 DC TR (02048) SL AIR 1400 DC AR (02049) 17,9 cm 1600 SLR AIR 1600 DC TR (02054) SLR AIR 1600 DC AR (02055) SL AIR 1600 DC TR (02050) SL AIR 1600 DC AR (02051) 17,9 cm SLR SMART S1 800 B DC (02130) SL SMART S1 800 B DC (02125) OUT SL SMART S1 1000 B DC (02126) 12,9 cm 12,9 cm FAN COIL UNITS HRV UNICO MONO AND MULTISPLIT SLIR 800 DC (01642) SLI 800 DC (01516) 14,2 cm SLIR 1100 DC (02364) SLI 1100 DC (02363) 21,7 cm SLIR 1400 DC (02071) SLI 1400 DC (02056) 21,7 cm SLIR 1600 DC (02072) SLI 1600 DC (02057) 21,7 cm 800 SLW 800 DC V2V TR (01786) SLW 800 DC V2V AR (01877) SLW 800 DC V3V TR (01789) SLW 800 DC V3V AR (01880) 12,9 cm SLIM DESIGN 1000 1200 1400 NEW SLW 1000 DC V2V TR (02467) NEW SLW 1000 DC V2V AR (02468) NEW SLW 1000 DC V3V TR (02465) NEW SLW 1000 DC V3V AR (02466) 22,6 cm NEW SLW 1200 DC V2V TR (02459) NEW SLW 1200 DC V2V AR (02460) NEW SLW 1200 DC V3V TR (02457) NEW SLW 1200 DC V3V AR (02458) 22,6 cm NEW SLW 1400 DC V2V TR (02463) NEW SLW 1400 DC V2V AR (02464) NEW SLW 1400 DC V3V TR (02461) NEW SLW 1400 DC V3V AR (02462) 22,6 cm LGW WALL S1 1200 DC (99283) 23,0 cm LGW WALL S1 1400 DC (99284) 23,0 cm Catalogue 2024 | January edition 69 PORTABLES Bi2 AIR SL SLR Ultraslim fan coil units, SL and SLR versions Compatible with: INTEGRAL DESIGN Front and side panels are joined for easy installation and maintenance. MULTISET CONTROL Integrated electronics allows touch operation, remote control and home automation connection. FEATURES · Heats, Cools, Dehumidifies and Filters. · Integral aesthetics with intake from the lower side. · Front in metal, sides in ABS. · Compact: Min thickness 12,9 cm max 15 cm. · Range consisting of 5 power modules. · DC brushless motor. · Monobloc body for work in comfort. · Motorised steel air delivery flap. · Anti-intrusion grilles on the air intake and outlet. · Removable filters placed on the air intake. · Remote control supplied (only for TR control). · Available in the colours: White RAL 9003 INTEGRATED CONTROLS AS STANDARD TR (Touch Remote) CONTROL: includes on-board touch control and remote control (supplied). Additionally, through a combination of keys, it is possible to remotely* control with a B0736 wall remote control or a home automation control (SiOS Control by Olimpia Splendid or MyHome by Bticino), via the Modbus RS485 ASCII serial protocol. AR (Analog Remote) CONTROL: allows remote control by interfacing with wall controls or home automation control systems via 0-10V analog input or contacts (for fan coil radiators, use the contact mode). It has a 230Vac output for control of a solenoid valve and a water probe inlet with the function of a minimum probe (for both modes of remote control). AR models on request. LAYOUT, DIMENSIONS, WEIGHT 1. Heat exchanger battery 2. High efficiency radiant heating panel (SLR version) 3. Tangential fan 4. Brushless DC electric motor 5. Air delivery flap and anti-intrusion delivery grille 6. Condensation trap 7. Front body in electrogalvanised sheet metal 8. Anti-intrusion intake grille 9. Sides in ABS 10. On-board touch control (TR version) K F SLR ONLY H J B C I D G E 200 A mm 695 B mm 599 C mm 679 D mm 129 E mm 150 Weight SL kg 11.5 Weight SLR kg 13.5 D 400 600 895 1095 599 599 679 679 129 129 150 150 13.0 15.5 15.5 19.5 A 800 1000 1295 1495 599 599 679 679 129 129 150 150 18.5 21.5 22.5 25.5 C B E INSTALLATION Floor mounted, wall mounted or (only for SL versions) ceiling mounted.** * With the exception of the combination with SIOS Control, in all other cases: Touch control on the machine, air probe on the machine and remote control disabled **Ceiling installation: kits required for ceiling installation and foot kit. The foot kit is optimised for floor installation. 70 SL ONLY Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS OUT TECHNICAL DATA 200 SL Air inverter (with TR command) 01851 SL Air inverter (with AR command) 01767 SLR Air inverter (with TR command) 01856 SLR Air omvormer (with AR command) 01772 Fan speed Lower Middle High Total power output in cooling mode a27/19 - w7/12 (a) (E) kW 0.38 0.71 0.82 Sensitive power output in cooling mode a27/19 - w7/12 (a) (E) kW 0.26 0.50 0.64 Fluid flow rate a27/19 - w7/12 (a) l/h 66.2 123.3 142.9 Water side head loss a27/19 - w7/12 (a) (E) kPa 3.8 10.6 13.1 Total power output in heating mode a20/15 - w50/- (b) (E) kW 0.64 0.84 1.05 Fluid flow rate a20/15 - w50/- (b) l/h 66.2 123.3 142.9 Water side head loss a20/15 - w50/- (b) (E) kPa 3.2 8.8 10.9 Total power output in heating mode a20/15 - w45/40 (c) (E) kW 0.54 0.70 0.88 Fluid flow rate a20/15 - w45/40 (c) l/h 91.9 119.9 150.0 Water side head loss a20/15 - w45/40 (c) (E) kPa 5.7 8.8 12.2 Absorbed power (E) W 5 7 11 Sound Power Lw (A) (E) dB(A) 38 45 52 Sound pressure Lp (A) (d) dB(A) 29 36 43 Air flow rate (f) m3/h 100 130 160 Battery water content l 0.47 Maximum operating pressure bar 10 Hydraulic fittings inch Eurocone 3/4 Electrical power supply V/ph/Hz 230/1/50 Max static heating efficiency (50°C) kW 0.37 Max static heating efficiency (70°C) kW 0.59 Water content of the radiant panel l 0.19 400 01852 01768 01857 01773 Lower Middle High 0.91 1.34 1.74 0.65 1.02 1.25 157.6 232.0 302.5 2.4 5.5 8.2 1.25 1.65 2.31 157.6 232.0 302.5 2.0 4.6 6.8 1.06 1.39 1.94 181.9 238.1 330.3 2.9 4.8 7.9 6 9 19 39 46 53 30 37 44 190 250 320 0.8 10 Eurocone 3/4 230/1/50 0.42 0.71 0.27 600 01853 01769 01858 01774 Lower Middle High 1.50 2.10 2.54 1.10 1.56 1.94 259.2 363.1 440.3 7.5 14.2 19 1.75 2.56 3.12 259.2 363.1 440.3 6.2 11.8 15.8 1.46 2.14 2.60 250.6 365.7 444.6 5.8 11.8 16.0 7 11 20 41 47 53 32 38 44 280 360 460 1.13 10 Eurocone 3/4 230/1/50 0.5 0.84 0.35 800 01854 01770 01859 01775 Lower Middle High 1.98 2.69 3.29 1.54 2.09 2.54 341.9 464.7 570.0 7.3 13.8 18.7 2.21 3.10 4.10 341.9 464.7 570.0 6.1 11.5 15.5 1.85 2.60 3.44 316.6 444.8 587.9 4.1 8.9 14.2 8 12 24 42 48 54 33 39 45 350 450 575 1.46 10 Eurocone 3/4 230/1/50 0.62 1.04 0.43 1000 01855 01771 01860 01776 Lower Middle High 2.17 3.25 3.78 1.71 2.42 2.98 374.8 561.4 654.8 5.7 13.1 18.2 3.05 3.77 4.67 374.8 561.4 654.8 4.7 10.9 15.1 2.56 3.16 3.91 438.1 541.0 668.5 6.4 9.8 13.9 9 14 27 42 48 54 33 39 45 400 510 650 1.8 10 Eurocone 3/4 230/1/50 0.77 1.28 0.50 SLR ONLY The above services refer to the following operating conditions: (a) Cooling mode at standard conditions: air temperature 27°C b.s. 19°C b.u., water inlet temperature 7°C, water outlet temperature 12°C (b) Heating mode conditions of use 1: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 50°C, water flow equal to the cooling water standard condition (c) Heating mode standard conditions: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 45°C, water outlet temperature 40°C (d) Sound pressure level valid for closed rooms with a volume of 100 m3 with a reverberation time of 0.5 s and installation on the floor/ceiling, sound emission on 1/4 sphere at 3 m distance (E) Eurovent certified data (f) Air flow rate measured with clean filters HYDRAULICS KIT CONTROLS ACCESSORIES B0736 B0921 INDRZ B0839 B0832 B0834 B0205 B0204 B0200 B0201 B0203 Wall-mounted Modbus chrono-thermostat kit Contact touch wall-mounted thermostat kit Addressing of the Modbus control kit LH-RH connection rotation extension kit 2-way valve group kit with 4-wire actuator 3-way valve group kit with 4-wire actuator Manual 2-way valve group kit Manual 2-way valve insulation kit Adapter connection kit for 1/2" gas thread Adapter connection kit for 3/4" gas thread Eurokonus 90° bending connection kit Optional accessory | Accessory not compatible SL SLR TR TR AR TR TR AESTHETIC KITS ACCESSORIES B0852 B0853 B0847 B0848 B0849 B0850 B0851 B0520 B0521 B0522 B0523 B0524 Floor mounting bracket kit Aesthetic kit feet for covering Back panel Back panel Back panel Back panel Back panel Ceiling-mount kit (condensation trap) Ceiling-mount kit (condensation trap) Ceiling-mount kit (condensation trap) Ceiling-mount kit (condensation trap) Ceiling-mount kit (condensation trap) SL SLR 1000 1000 1000 1000 200 200 400 400 600 600 800 800 OUT 1000 1000 200 400 600 800 OUT 1000 Accessory description on page 92 HRV UNICO MONO AND MULTISPLIT PORTABLES Please note that optional accessories are available for purchase in conjunction with all models of the terminal. When compatibility is only possible with certain sizes or models, the information is shown in the table. Catalogue 2024 | January edition 71 Bi2 AIR SL SLR Slim fan coil units, SL and SLR versions Compatible with: PRO-POWER Up to 4.85 kW of power, for larger spaces and colder climates. INTEGRAL DESIGN Front and side panels are joined for easy installation and maintenance. MULTISET CONTROL Integrated electronics allows touch operation, remote control and home automation connection. FEATURES · Heats, Cools, Dehumidifies and Filters. · Integral aesthetics with intake from the lower side. · Front in metal, sides in ABS. · Compact: Min thickness 17,9 cm max 20 cm. · Range consisting of 3 power modules. · DC brushless motor. · Monobloc body for work in comfort. · Double motorised steel air delivery flap. · Anti-intrusion grilles on the air intake and outlet. · Removable filters placed on the air intake. · Remote control supplied (only for TR control). · Available in the colours: White RAL 9003 INTEGRATED CONTROLS AS STANDARD TR (Touch Remote) CONTROL: includes on-board touch control and remote control (supplied). Additionally, through a combination of keys, it is possible to remotely* control with a B0736 wall remote control or a home automation control (SiOS Control by Olimpia Splendid or MyHome by Bticino), via the Modbus RS485 serial protocol (ASCII or RTU). In addition, a correction of the room temperature read can be added via the user interface. AR (Analog Remote) CONTROL: Allows remote control by interfacing with wall controls or home automation control systems via 0-10V analog input or contacts (for radiant fan coil units, use the contact mode). It has a 230Vac output for control of a solenoid valve and a water probe inlet with the function of a minimum probe (for both modes of remote control). AR models on request. LAYOUT, DIMENSIONS, WEIGHT 1. Heat exchanger battery 2. High efficiency radiant heating 6. Condensation trap 7. Front body in electrogalvanised 1100 1400 1600 panel (SLR version) sheet metal A mm 1345 1345 1415 3. Tangential fan 8. Anti-intrusion intake grille B mm 599 599 599 4. Brushless DC electric motor 9. Sides in ABS C mm 719 719 719 5. Air delivery flap and anti-intrusion 10. On-board touch control (TR D mm 179 179 179 delivery grille version) E mm 200 200 200 Weight SL kg 22,0 22.5 24 K F SLR ONLY Weight SLR kg 24,0 24,5 26 B H J C I D G E INSTALLATION Floor mounted, wall mounted or (only for SL versions) ceiling mounted.** * With the exception of the combination with SIOS Control, in all other cases: Touch control on the machine, air probe on the machine and remote control disabled **Ceiling installation: kits required for ceiling installation and foot kit. The foot kit is optimised for floor installation. 72 SOLO SL Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA 1100 SL Air inverter (with TR command) 02362 SL Air inverter (with AR command) 02361 SLR Air inverter (with TR command) 02360 SLR Air omvormer (with AR command) 02359 Fan speed Lower Middle High Total power output in cooling mode a27/19 - w7/12 (a) (E) kW 2.43 3.24 3.85 Sensitive power output in cooling mode a27/19 - w7/12 (a) (E) kW 1.78 2.41 2.93 Fluid flow rate a27/19 - w7/12 (a) l/h 417.4 557.3 664.2 Water side head loss a27/19 - w7/12 (a) (E) kPa 13.9 23.7 32.6 Total power output in heating mode a20/15 - w50/- (b) (E) kW 2.88 4.06 4.8 Fluid flow rate a20/15 - w50/- (b) l/h 417.4 557.3 664.2 Water side head loss a20/15 - w50/- (b) (E) kPa 12.3 21.1 29.1 Total power output in heating mode a20/15 - w45/40 (c) (E) kW 2.6 3.4 4.11 Fluid flow rate a20/15 - w45/40 (c) l/h 449 590 712 Water side head loss a20/15 - w45/40 (c) (E) kPa 14.3 23.5 33.3 Absorbed power (E) W 6 13 26 Sound Power Lw (A) (E) dB(A) 39 46 50 Sound pressure Lp (A) (d) dB(A) 30 41 46 Air flow rate (f) m3/h 460 610 765 Battery water content l 1.94 Maximum operating pressure bar 10 Hydraulic fittings inch Eurocone 3/4 Electrical power supply V/ph/Hz 230/1/50 Max static heating efficiency (50°C) kW 0.45 Max static heating efficiency (70°C) kW 0.8 Water content of the radiant panel l 0.43 1400 02048 02049 02052 02053 Lower Middle High 3.05 3.78 4.45 2.14 2.69 3.20 525.6 652.4 769.9 19 27.8 37.2 3.61 4.53 5.50 525.6 652.4 769.9 16.2 23.7 31.7 3.07 3.87 4.70 527.1 663.4 803.9 17.1 25.8 35.5 6 13 26 38 49 54 30 41 46 460 610 765 2.33 10 Eurocone 3/4 230/1/50 0.45 0.8 0.43 1600 02050 02051 02054 02055 Lower Middle High 3.28 4.09 4.85 2.30 2.90 3.50 565.2 706 839.2 20.9 30.8 41 3.85 4.87 5.90 565.2 706 839.2 19.4 28.6 35.7 3.28 4.16 5.05 563.1 713 863.6 20.2 30.8 38.8 6 15 29 39 50 55 31 42 47 490 655 820 2.5 10 Eurocone 3/4 230/1/50 0.5 0.9 0.43 SLR ONLY The above services refer to the following operating conditions: (a) Cooling mode at standard conditions: air temperature 27°C b.s. 19°C b.u., water inlet temperature 7°C, water outlet temperature 12°C (b) Heating mode conditions of use 1: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 50°C, water flow equal to the cooling water standard condition (c) Heating mode standard conditions: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 45°C, water outlet temperature 40°C (d) Sound pressure level valid for closed rooms with a volume of 100 m3 with a reverberation time of 0.5 s and installation on the floor/ceiling, sound emission on 1/4 sphere at 3 m distance (E) Eurovent certified data (f) Air flow rate measured with clean filters HYDRAULICS KIT CONTROLS ACCESSORIES B0736 B0921 INDRZ B0839 B0832 B0834 B0205 B0204 B0200 B0201 B0203 Wall-mounted Modbus chrono-thermostat kit Contact touch wall-mounted thermostat kit Addressing of the Modbus control kit LH-RH connection rotation extension kit 2-way valve group kit with 4-wire actuator 3-way valve group kit with 4-wire actuator Manual 2-way valve group kit Manual 2-way valve insulation kit Adapter connection kit for 1/2" gas thread Adapter connection kit for 3/4" gas thread Eurokonus 90° bending connection kit Optional accessory | Accessory not compatible SL SLR TR TR AR TR TR AESTHETIC KITS B0875 B0874 B0876 B0876 B0877 B0878 B0878 B0879 Floor mounting bracket kit Aesthetic kit feet for covering Back panel Back panel Back panel Ceiling-mount kit (condensation trap) Ceiling-mount kit (condensation trap) Ceiling-mount kit (condensation trap) SL SLR 1100 1100 1100 1100 1100 1100 1400 1400 1600 1600 1100 1400 1600 Accessory description on page 92 HRV UNICO MONO AND MULTISPLIT PORTABLES Please note that optional accessories are available for purchase in conjunction with all models of the terminal. When compatibility is only possible with certain sizes or models, the information is shown in the table. Catalogue 2024 | January edition 73 Bi2 WALL Ultra-slim high-wall terminal units Compatible with: REVERSIBILTY By rotating the display, Bi2 Wall can be installed as a split unit or a console machine. FAMILY FEELING Similar design as the Bi2 Air terminal to allow aesthetically coordinated installations in the same environment. MULTISET CONTROL Integrated electronics allows touch operation, remote control and home automation connection. FEATURES INTEGRATED CONTROLS AS STANDARD · Heats, Cools, Dehumidifies and Filters · Brushless DC motor · Equipped with large motorised flap · Total flat aesthetics · Compact: Thickness min. 12.9 cm max 15 cm. · Range consisting of 3 models of different power. · Fan coil unit supplied with 2 or 3-way valve integrated with 4 wire electrothermic actuators. · Monobloc body for comfortable working. · Motorised steel air delivery flap. · Extractable filters placed on the air intake. · Remote control supplied (only for TR control) · Robust metal body · Available in the colours: White RAL 9003 TR (Touch Remote) CONTROL: includes on-board touch control and a remote control (supplied). Additionally, through a combination of keys, it is possible to remotely* control with a B0736 wall remote control or a home automation control (SiOS Control by Olimpia Splendid or MyHome by Bticino), via the Modbus RS485 (ASCII or RTU) serial protocol. In addition through the user interface it is possible to add a correction on the read ambient temperature. AR (Analog Remote) CONTROL: allows remote control by interfacing with wall controls or home automation control systems via 0-10V analog input or contacts (for radiant fan coil units, use the contact mode). It has a 230Vac output for control of a solenoid valve and a water probe inlet with the function of a minimum probe (only for use in contact mode). AR models on request. LAYOUT, DIMENSIONS, WEIGHT A D 400 600 800 A mm 906 1106 1306 B mm 380 380 380 C mm 129 129 129 D mm 150 150 150 Weight kg 13 14.5 16 B C INSTALLATION Console and high-wall. * With the exception of the combination with SIOS Control, in all other cases: Touch control on the machine, air probe on the machine and remote control disabled 74 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA 400 SLW inverter (with 2-way valve and TR command) 01784 SLW inverter (with 2-way valve and AR command) 01875 SLW inverter (with 3-way valve and TR command) 01787 SLW inverter (with 3-way valve and AR command) 01878 Fan speed Lower Middle High Total power output in cooling mode a27/19 - w7/12 (a) (E) kW 0.52 0.71 1.01 Sensitive power output in cooling mode a27/19 - w7/12 (a) (E) kW 0.42 0.59 0.91 Fluid flow rate a27/19 - w7/12 (a) l/h 90.6 124.0 177.0 Water side head loss a27/19 - w7/12 (a) (E) kPa 2.8 5.2 8.9 Total power output in heating mode a20/15 - w50/- (b) (E) kW 0.67 0.99 1.55 Fluid flow rate a20/15 - w50/- (b) l/h 90.6 124.0 177.0 Water side head loss a20/15 - w50/- (b) (E) kPa 2.4 4.5 7.1 Total power output in heating mode a20/15 - w45/40 (c) (E) kW 0.58 0.86 1.40 Fluid flow rate a20/15 - w45/40 (c) l/h 99.1 146.3 237.5 Water side head loss a20/15 - w45/40 (c) (E) kPa 3.4 6.7 11.6 Absorbed power (E) W 7 11 19 Sound Power Lw (A) (E) dB(A) 43 49 57 Sound pressure Lp (A) (d) dB(A) 34 40 48 Air flow rate (f) m3/h 140 190 290 Battery water content l 0.3 Maximum operating pressure bar 8 Hydraulic fittings inch Eurocone 3/4 Electrical power supply V/ph/Hz 230/1/50 Max static heating efficiency (50°C) kW - Max static heating efficiency (70°C) kW - Water content of the radiant panel l - 600 01785 01876 01788 01879 Lower Middle High 0.69 0.89 1.23 0.58 0.80 1.15 120.1 155.1 215.5 4.9 6 7.9 0.98 1.37 2.16 120.1 155.1 215.5 1.9 2.9 2.5 0.86 1.20 1.90 146.5 204.6 322.8 6.7 11.9 5.4 8 12 23 43 50 58 34 41 49 190 260 400 0.4 8 Eurocone 3/4 230/1/50 - - - 800 01786 01877 01789 01880 Lower Middle High 0.77 1.09 1.82 0.65 0.95 1.47 134.0 189.7 317.7 2.1 4.8 11 1.14 1.68 2.85 134.0 189.7 317.7 2.0 4.6 8.8 0.99 1.45 2.50 168.1 247.8 425.4 8.5 16.4 15.3 9 13 27 43 50 58 34 41 49 200 280 430 0.5 8 Eurocone 3/4 230/1/50 - - - The above services refer to the following operating conditions: (a) Cooling mode at standard conditions: air temperature 27°C b.s. 19°C b.u., water inlet temperature 7°C, water outlet temperature 12°C (b) Heating mode conditions of use 1: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 50°C, water flow equal to the cooling water standard condition (c) Heating mode standard conditions: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 45°C, water outlet temperature 40°C (d) Sound pressure level valid for closed rooms with a volume of 100 m3 with a reverberation time of 0.5 s and installation on the floor/ceiling, sound emission on 1/4 sphere at 3 m distance (E) Eurovent certified data (f) Air flow rate measured with clean filters ACCESSORIES SLW CONTROLS B0736 Wall-mounted Modbus chrono-thermostat kit TR B0921 Contact touch wall-mounted thermostat kit AR INDRZ Addressing of the Modbus control kit TR Accessory description on page 92 Maximum installation versatility Bi2 Wall is the first ultraslim hydronic fan coil that can be installed as a high wall "split" (High Wall configuration) or as a low wall consolle machine (Consolle configuration). Depending on the installation configuration, with a combination of keys on the control on the machine, the display digits are rotated. In the High Wall configuration the water connections are positioned on the right and the display is positioned on the left. In the Consolle configuration the water connections are positioned on the left and the display is positioned on the right. DISPLAY HYDRAULIC CONNECTIONS DISPLAY HYDRAULIC CONNECTIONS HRV UNICO MONO AND MULTISPLIT PORTABLES Please note that optional accessories are available for purchase in conjunction with all models of the terminal. When compatibility is only possible with certain sizes or models, the information is shown in the table. Catalogue 2024 | January edition 75 NEW Bi2 WALL Slim high-wall terminal units Compatible with: COMPACT DESIGN Specifically designed to minimise volume and expand the possibilities for over-door installation. With equal power, it is among the most compact on the market. FAMILY FEELING Similar design as the Bi2 Air terminal to allow aesthetically coordinated installations in the same environment. MULTISET CONTROL Integrated electronics allows touch operation, remote control and home automation connection. FEATURES INTEGRATED CONTROLS AS STANDARD · Heats, cools, dehumidifies and filters. · DC brushless motor · Total flat aesthetics. · Range composed of 3 power models. · Terminal unit supplied with 2 or 3-way valve integrated with 4-wire electro- thermal actuator. · Single-piece body for working comfortably. · Steel air delivery flap, motorised. · Extractable filters located on the air intake. · Remote control supplied (only for TR control). · Optional condensation drain pump. · Available in the colours: White RAL 9003 TR (Touch Remote) CONTROL: includes on-board touch control and remote control (supplied). Additionally, through a combination of keys, it is possible to obtain remote* control with a B0736 wall remote control or a home automation control (SiOS Control by Olimpia Splendid or MyHome by Bticino), via the Modbus RS485 serial protocol (ASCII or RTU). In addition, a correction of the room temperature read can be added via the user interface. AR (Analogic Remote) CONTROL: Allows remote control by interfacing with wall controls or home automation control systems via 0-10V analogue input or contacts (for fan coil radiators, use the contact mode). It has a 230Vac output for control of a solenoid valve and a water probe inlet with the function of a minimum probe (for both modes of remote control). AR models on request. LAYOUT, DIMENSIONS, WEIGHT A C 1000 1200 1400 A mm 940 940 940 B mm 303 303 303 C mm 226 226 226 Weight kg 11 12 12 B INSTALLATION High-wall * With the exception of the combination with SIOS Control, in all other cases: Touch control on the machine, air probe on the machine and remote control disabled 76 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA 1000 SLW inverter (with 2-way valve and TR command) 02467 SLW inverter (with 2-way valve and AR command) 02468 SLW inverter (with 3-way valve and TR command) 02465 SLW inverter (with 3-way valve and AR command) 02466 Fan speed Lower Middle High Total power output in cooling mode a27/19 - w7/12 (a) (E) kW 1.10 1.90 2.40 Sensitive power output in cooling mode a27/19 - w7/12 (a) (E) kW 0.91 1.55 1.98 Fluid flow rate a27/19 - w7/12 (a) l/h 195.9 326.4 411.2 Water side head loss a27/19 - w7/12 (a) (E) kPa 7.2 19.4 32.4 Total power output in heating mode a20/15 - w50/- (b) (E) kW 1.59 2.62 3.31 Fluid flow rate a20/15 - w50/- (b) l/h 195.9 326.4 411.2 Water side head loss a20/15 - w50/- (b) (E) kPa 6.8 18.6 31.6 Total power output in heating mode a20/15 - w45/40 (c) (E) kW 1.43 2.37 2.91 Fluid flow rate a20/15 - w45/40 (c) l/h 237.8 399.3 500.2 Water side head loss a20/15 - w45/40 (c) (E) kPa 10.0 28.1 42.9 Absorbed power (E) W 8 15 22 Sound Power Lw (A) (E) dB(A) 37 45 51 Sound pressure Lp (A) (d) dB(A) 23 32 39 Air flow rate (f) m3/h 227 393 517 Battery water content l 0.75 Maximum operating pressure bar 8 Hydraulic fittings inch Piana 1/2 Electrical power supply V/ph/Hz 230/1/50 Max static heating efficiency (50°C) kW - Max static heating efficiency (70°C) kW - Water content of the radiant panel l - 1200 02459 02460 02457 02458 Lower Middle High 1.90 2.50 3.10 1.62 2.10 2.59 325.7 428.9 532.3 14.8 24.2 36.8 2.67 3.40 4.17 325.7 428.9 532.3 14.1 23.2 34.9 2.30 2.94 3.61 395.1 506.3 620.4 21.0 33.9 50.1 9 14 21 38 43 48 24 30 36 389 510 640 0.97 8 Piana 1/2 230/1/50 - - - 1400 02463 02464 02461 02462 Lower Middle High 2.20 3.20 3.90 1.86 2.68 3.33 378.3 549.2 665.9 19.1 39.1 58.2 3.02 4.30 5.05 378.3 549.2 665.9 18.5 38.3 56.6 2.62 3.72 4.59 450.1 640.2 789.8 27.2 52.9 80.1 11 23 38 40 50 56 27 37 44 450 661 856 0.97 8 Piana 1/2 230/1/50 - - - The above services refer to the following operating conditions: (a) Cooling mode at standard conditions: air temperature 27°C b.s. 19°C b.u., water inlet temperature 7°C, water outlet temperature 12°C (b) Heating mode conditions of use 1: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 50°C, water flow equal to the cooling water standard condition (c) Heating mode standard conditions: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 45°C, water outlet temperature 40°C (d) Sound pressure level valid for closed rooms with a volume of 100 m3 with a reverberation time of 0.5 s and installation on the floor/ceiling, sound emission on 1/4 sphere at 3 m distance (E) Eurovent certified data (f) Air flow rate measured with clean filters CONTROLS ACCESSORIES B0736 B0921 INDRZ B0983 Wall-mounted Modbus chrono-thermostat kit Contact touch wall-mounted thermostat kit Addressing of the Modbus control kit Condensation pump kit Accessory description on page 92 SLW TR AR TR NEW 1000 A concentration of power and design above the door With one of the lowest sound pressure levels in the category, Bi2 Wall slim has been carefully designed to achieve one of the highest power/volume ratios on the market. This compactness allows for easy installation above the door in most situations. The space above the door is in fact almost always unused and is therefore perfect for installing the terminal unit used for the comfort of the room. The optional kit for condensation pump allows solving even the most complex drainage situations, where the slopes do not allow a natural discharge of the water. Its features therefore make it the perfect terminal not only for new buildings with limited space, but also for more complex renovations with high performance demands. HRV UNICO MONO AND MULTISPLIT PORTABLES Please note that optional accessories are available for purchase in conjunction with all models of the terminal. When compatibility is only possible with certain sizes or models, the information is shown in the table. Catalogue 2024 | January edition 77 Bi2 SMART S1 SL SLR Ultraslim fan coil units, SL and SLR versions Compatible with: TOTAL FLAT DESIGN Linear aesthetics (with bottom suction system) for maximum integration with the surrounding architecture. FEATURES · Air Conditions, Dehumidifies, Heats and Filters. · Fan coil unit with integrated radiant panel (SLR version). · Compact: Thickness min 12.9 cm - max 15 cm · Range consisting of 5 power models (4 for the SLR version) · Brushless DC motor · Metal front, Smart sides in ABS · Total Flat aesthetic with air extraction system from the bottom side · Standard configuration with short delivery grille, symmetrical, for installation of the touch controls possible on site · Available in the colours: White RAL 9003 LAYOUT, DIMENSIONS, WEIGHT 1. Valve with thermoelectric actuator 5. High-efficiency tangential fan (accessory kit) 6. Condensation trap A 2. Tubular radiant heating panel (SLR 7. Brushless DC motor inverter B version) 8. Electronic control (accessory kit) C 3. High-efficiency battery 4. Water temperature probe D E 200 400 600 800 1000 mm 759 959 1159 1359 1559 mm 579 579 579 579 579 mm 659 659 659 659 659 mm 129 129 129 129 129 mm 150 150 150 150 150 I Weight SL kg 11.5 13 15.5 18.5 21.5 E Weight SLR kg 13,5 15,5 19,5 22,5 - C B A D D H B C G F SLR ONLY E INSTALLATION Installation floor mounted, wall mounted or (only for SL versions) ceiling-mounted.* * Ceiling installation: kits required for ceiling installation and foot kit.Present version of foot kit specifically for ceiling installation. 78 SL ONLY Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS OUT TECHNICAL DATA SL Smart S1 inverter SLR Smart S1 inverter Fan speed Total power output in cooling mode Sensitive power output in cooling mode Fluid flow rate Water side head loss Total power output in heating mode Fluid flow rate Water side head loss Total power output in heating mode Fluid flow rate Water side head loss Absorbed power Sound Power Lw (A) Sound pressure Lp (A) Air flow rate Battery water content Maximum operating pressure Hydraulic fittings Electrical power supply Max static heating efficiency (50°C) Max static heating efficiency (70°C) Water content of the radiant panel 200 02122 02127 Lower Middle High a27/19 - w7/12 (a) (E) kW 0.38 0.71 0.82 a27/19 - w7/12 (a) (E) kW 0.26 0.50 0.64 a27/19 - w7/12 (a) l/h 66.2 123.3 142.9 a27/19 - w7/12 (a) (E) kPa 3.8 10.6 13.1 a20/15 - w50/- (b) (E) kW 0.64 0.84 1.05 a20/15 - w50/- (b) l/h 66.2 123.3 142.9 a20/15 - w50/- (b) (E) kPa 3.2 8.8 10.9 a20/15 - w45/40 (c) (E) kW 0.54 0.70 0.88 a20/15 - w45/40 (c) l/h 91.9 119.9 150.0 a20/15 - w45/40 (c) (E) kPa 5.7 8.8 12.2 (E) W 5 7 11 (E) dB(A) 38 45 52 (d) dB(A) 29 36 43 (f) m3/h 100 130 160 l 0.47 bar 10 inch Eurocone 3/4 V/ph/Hz 230/1/50 kW 0.37 kW 0.59 l 0.19 400 02123 02128 Lower Middle High 0.91 1.34 1.74 0.65 1.02 1.25 157.6 232.0 302.5 2.4 5.5 8.2 1.25 1.65 2.31 157.6 232.0 302.5 2.0 4.6 6.8 1.06 1.39 1.94 181.9 238.1 330.3 2.9 4.8 7.9 6 9 19 39 46 53 30 37 44 190 250 320 0.8 10 Eurocone 3/4 230/1/50 0.42 0.71 0.27 600 02124 02129 Lower Middle High 1.50 2.10 2.54 1.10 1.56 1.94 259.2 363.1 440.3 7.5 14.2 19 1.75 2.56 3.12 259.2 363.1 440.3 6.2 11.8 15.8 1.46 2.14 2.60 250.6 365.7 444.6 5.8 11.8 16.0 7 11 20 41 47 53 32 38 44 280 360 460 1.13 10 Eurocone 3/4 230/1/50 0.5 0.84 0.35 800 02125 02130 Lower Middle High 1.98 2.69 3.29 1.54 2.09 2.54 341.9 464.7 570.0 7.3 13.8 18.7 2.21 3.10 4.10 341.9 464.7 570.0 6.1 11.5 15.5 1.85 2.60 3.44 316.6 444.8 587.9 4.1 8.9 14.2 8 12 24 42 48 54 33 39 45 350 450 575 1.46 10 Eurocone 3/4 230/1/50 0.62 1.04 0.43 1000 02126 - Lower Middle High 2.17 3.25 3.78 1.71 2.42 2.98 374.8 561.4 654.8 5.7 13.1 18.2 3.05 3.77 4.67 374.8 561.4 654.8 4.7 10.9 15.1 2.56 3.16 3.91 438.1 541.0 668.5 6.4 9.8 13.9 9 14 27 42 48 54 33 39 45 400 510 650 1.8 10 Eurocone 3/4 230/1/50 - SLR ONLY The above services refer to the following operating conditions: (a) Cooling mode at standard conditions: air temperature 27°C b.s. 19°C b.u., water inlet temperature 7°C, water outlet temperature 12°C (b) Heating mode conditions of use 1: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 50°C, water flow equal to the cooling water standard condition (c) Heating mode standard conditions: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 45°C, water outlet temperature 40°C (d) Sound pressure level valid for closed rooms with a volume of 100 m3 with a reverberation time of 0.5 s and installation on the floor/ceiling, sound emission on 1/4 sphere at 3 m distance (E) Eurovent certified data (f) Air flow rate measured with clean filters HYDRAULICS KIT CONTROLS ACCESSORIES B0872 B0873 B0736 B0921 B0633 B0832 B0834 B0205 B0204 B0200 B0201 B0203 On-board autonomous flat touch control kit Electronic contacts/0-10V remote control kit Wall-mounted Modbus chrono-thermostat kit Contact touch wall-mounted thermostat kit LH-RH connection rotation extension kit 2-way valve group kit with 4-wire actuator 3-way valve group kit with 4-wire actuator Manual 2-way valve group kit Manual 2-way valve insulation kit Adapter connection kit for 1/2" gas thread Adapter connection kit for 3/4" gas thread Eurokonus 90° bending connection kit SL SLR AESTHETIC KITS B0938 B0937 B0982 B0520 B0521 B0522 B0523 B0524 Floor mounting bracket kit Aesthetic kit feet for covering Aesthetic ceiling feet kit Ceiling-mount kit (condensation trap) Ceiling-mount kit (condensation trap) Ceiling-mount kit (condensation trap) Ceiling-mount kit (condensation trap) Ceiling-mount kit (condensation trap) SL SLR NEW 200 400 600 800 OUT 1000 Optional accessory | Accessory not compatible Accessory description on page 92 HRV UNICO MONO AND MULTISPLIT PORTABLES Please note that optional accessories are available for purchase in conjunction with all models of the terminal. When compatibility is only possible with certain sizes or models, the information is shown in the table. Catalogue 2024 | January edition 79 Bi2 NAKED SLI SLIR Ultraslim fan coil units, SLI and SLIR versions SPACE SAVING Formwork measuring only 14.2 cm deep. Compatible with: SMALL FOOTPRINT Closing panel in metal for wall installation. FEATURES · Air Conditions, Dehumidifies, Heats and Filter · Recessed version (with integrated radiant panel for the SLIR version) · Compact: Recessed wall-mounted thickness of only 142 mm · Range consisting of 5 models of different power · Brushless DC motor · SLIR version available only with hydraulic connections on the left. · Metal closing panel available in the colours: white RAL 9003 LAYOUT, DIMENSIONS, WEIGHT Fan coil unit 200 400 600 800 A mm 525 725 925 1125 B mm 576 576 576 576 C mm 126 126 126 126 Weight SLI kg 7 9.5 11 14 SLIR ONLY Weight SLIR kg 9 12 15 18 A C B 80 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS INSTALLATION Wall with panel Required accessories: recessed formwork and closing panel. Wall with grilles Required accessories: air extraction kit and insulated 90° delivery plenum (grilles and panel not supplied). SLI ONLY False ceiling Required accessories: air extraction kit, telescopic top or insulated 90° delivery plenum, delivery grilles and air intake grilles with an airfoil profile. SLI ONLY Recessed formwork Closing panel 200 400 600 800 200 400 600 800 A mm 713 913 1113 1313 A mm 772 972 1172 1372 B mm 725 725 725 725 B mm 754 754 754 754 C mm 142 142 142 142 A C A B B HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 81 TECHNICAL DATA SLI inverter SLIR inverter Fan speed Total power output in cooling mode Sensitive power output in cooling mode Fluid flow rate Water side head loss Total power output in heating mode Fluid flow rate Water side head loss Total power output in heating mode Fluid flow rate Water side head loss Absorbed power Sound Power Lw (A) Sound pressure Lp (A) Air flow rate Battery water content Maximum operating pressure Hydraulic fittings Electrical power supply Max static heating efficiency (50°C) Max static heating efficiency (70°C) Water content of the radiant panel 200 01513 01639 Lower Middle High a27/19 - w7/12 (a) (E) kW 0.38 0.71 0.82 a27/19 - w7/12 (a) (E) kW 0.26 0.50 0.64 a27/19 - w7/12 (a) l/h 66.2 123.3 142.9 a27/19 - w7/12 (a) (E) kPa 3.8 10.6 13.1 a20/15 - w50/- (b) (E) kW 0.64 0.84 1.05 a20/15 - w50/- (b) l/h 66.2 123.3 142.9 a20/15 - w50/- (b) (E) kPa 3.2 8.8 10.9 a20/15 - w45/40 (c) (E) kW 0.54 0.70 0.88 a20/15 - w45/40 (c) l/h 91.9 119.9 150.0 a20/15 - w45/40 (c) (E) kPa 5.7 8.8 12.2 (E) W 5 7 11 (E) dB(A) 38 45 52 (d) dB(A) 29 36 43 (f) m3/h 100 130 160 l 0.47 bar 10 inch Eurocone 3/4 V/ph/Hz 230/1/50 kW 0.37 kW 0.59 l 0.27 400 01514 01640 Lower Middle High 0.91 1.34 1.74 0.65 1.02 1.25 157.6 232.0 302.5 2.4 5.5 8.2 1.25 1.65 2.31 157.6 232.0 302.5 2.0 4.6 6.8 1.06 1.39 1.94 181.9 238.1 330.3 2.9 4.8 7.9 6 9 19 39 46 53 30 37 44 190 250 320 0.8 10 Eurocone 3/4 230/1/50 0.42 0.71 0.35 600 01515 01641 Lower Middle High 1.50 2.10 2.54 1.10 1.56 1.94 259.2 363.1 440.3 7.5 14.2 19 1.75 2.56 3.12 259.2 363.1 440.3 6.2 11.8 15.8 1.46 2.14 2.60 250.6 365.7 444.6 5.8 11.8 16.0 7 11 20 41 47 53 32 38 44 280 360 460 1.13 10 Eurocone 3/4 230/1/50 0.50 0.84 0.43 800 01516 01642 Lower Middle High 1.98 2.69 3.29 1.54 2.09 2.54 341.9 464.7 570.0 7.3 13.8 18.7 2.21 3.10 4.10 341.9 464.7 570.0 6.1 11.5 15.5 1.85 2.60 3.44 316.6 444.8 587.9 4.1 8.9 14.2 8 12 24 42 48 54 33 39 45 350 450 575 1.46 10 Eurocone 3/4 230/1/50 0.62 1.04 0.50 SLIR ONLY The above services refer to the following operating conditions: (a) Cooling mode at standard conditions: air temperature 27°C b.s. 19°C b.u., water inlet temperature 7°C, water outlet temperature 12°C (b) Heating mode conditions of use 1: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 50°C, water flow equal to the cooling water standard condition (c) Heating mode standard conditions: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 45°C, water outlet temperature 40°C (d) Sound pressure level valid for closed rooms with a volume of 100 m3 with a reverberation time of 0.5 s and installation on the floor/ceiling, sound emission on 1/4 sphere at 3 m distance (E) Eurovent certified data (f) Air flow rate measured with clean filters KIT FOR RECESS WITH FORMWORK HYDRAULICS KIT CONTROLS ACCESSORIES B0872 B0873 B0736 B0921 B0633 B0832 B0834 B0205 B0204 B0200 B0201 B0203 B0568 B0569 B0570 B0571 B0950 B0951 B0952 B0953 B0955 B0956 B0957 B0958 On-board autonomous flat touch control kit Electronic contacts/0-10V remote control kit Wall-mounted Modbus chrono-thermostat kit Contact touch wall-mounted thermostat kit LH-RH connection rotation extension kit 2-way valve group kit with 4-wire actuator 3-way valve group kit with 4-wire actuator Manual 2-way valve group kit Manual 2-way valve insulation kit Adapter connection kit for 1/2" gas thread Adapter connection kit for 3/4" gas thread Eurokonus 90° bending connection kit Formwork for recessed installation Formwork for recessed installation Formwork for recessed installation Formwork for recessed installation Radiant closing panel RAL 9003 Radiant closing panel RAL 9003 Radiant closing panel RAL 9003 Radiant closing panel RAL 9003 Closing panel RAL 9003 Closing panel RAL 9003 Closing panel RAL 9003 Closing panel RAL 9003 Optional accessory | Accessory not compatible SLI SLIR 200 200 400 400 600 600 800 800 200 400 600 800 200 400 600 800 Accessory description on page 92 Please note that optional accessories are available for purchase in conjunction with all models of the terminal. When compatibility is only possible with certain sizes or models, the information is shown in the table. KIT FOR RECESS WITHOUT FORMWORK KIT FOR RECESS WITHOUT FORMWORK B0550 B0551 B0552 B0553 B0559 B0560 B0561 B0562 B0194 B0195 B0196 B0197 B0160 B0161 B0162 B0163 B0165 B0166 B0167 B0168 Air delivery grille with airfoil profile Air delivery grille with airfoil profile Air delivery grille with airfoil profile Air delivery grille with airfoil profile Air intake grille with airfoil profile Air intake grille with airfoil profile Air intake grille with airfoil profile Air intake grille with airfoil profile Intake kit Intake kit Intake kit Intake kit Telescopic top delivery plenum Telescopic top delivery plenum Telescopic top delivery plenum Telescopic top delivery plenum Insulated 90° delivery plenum Insulated 90° delivery plenum Insulated 90° delivery plenum Insulated 90° delivery plenum SLI SLIR 200 400 600 800 200 400 600 800 200 400 600 800 200 400 600 800 200 400 600 800 82 Catalogue 2024 | January edition 83 PORTABLES MONO AND MULTISPLIT UNICO HRV FAN COIL UNITS HEAT PUMPS BMS Bi2 NAKED SLI SLIR Slim fan coil units, SLI and SLIR versions Compatible with: PRO-POWER Up to 4.85 kW of power, for larger spaces and colder climates. SPACE SAVING Formwork measuring only 21.7 cm deep. SMALL FOOTPRINT Closing panel in metal for wall installation. FEATURES · Air Conditions, Dehumidifies, Heats and Filter · Recessed version (with integrated radiant panel for the SLIR version) · Compact: Recessed wall-mounted thickness of only 217 mm · Range consisting of 3 models of different power · Brushless DC motor · SLIR version available only with hydraulic connections on the left. · Metal closing panel available in the colours: white RAL 9003 LAYOUT, DIMENSIONS, WEIGHT Fan coil unit SLIR ONLY 1100 A mm 1110 B mm 599 C mm 198 Weight SLI kg 17.5 Weight SLIR kg 19.5 AA 1400 1110 599 198 18 20 1600 1180 599 198 19.5 21 CC B B 84 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS INSTALLATION Wall with panel Required accessories: recessed formwork and closing panel. Wall with grilles Required accessories: air extraction kit and insulated 90° delivery plenum (grilles and panel not supplied). SLI ONLY False ceiling Required accessories: air extraction kit, telescopic top or insulated 90° delivery plenum, delivery grilles and air intake grilles with an airfoil profile. SLI ONLY Recessed formwork Closing panel 1100 1400 1600 1100 1400 1600 A mm 1513 1513 1513 A mm 1572 1572 1572 B mm 725 725 725 B mm 754 754 754 C mm 217 217 217 A C A B B HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 85 TECHNICAL DATA SLI inverter SLIR inverter Fan speed Total power output in cooling mode Sensitive power output in cooling mode Fluid flow rate Water side head loss Total power output in heating mode Fluid flow rate Water side head loss Total power output in heating mode Fluid flow rate Water side head loss Absorbed power Sound Power Lw(A) Sound pressure Lp (A) Air flow rate Battery water content Maximum operating pressure Hydraulic fittings Electrical power supply Max static heating efficiency (50°C) Max static heating efficiency (70°C) Water content of the radiant panel 1100 02363 02364 Lower Middle High a27/19 - w7/12 (a) (E) kW 2.43 3.24 3.85 a27/19 - w7/12 (a) (E) kW 1.78 2.41 2.93 a27/19 - w7/12 (a) l/h 417.4 557.3 664.2 a27/19 - w7/12 (a) (E) kPa 13.9 23.7 32.6 a20/15 - w50/- (b) (E) kW 2.88 4.06 4.8 a20/15 - w50/- (b) l/h 417.4 557.3 664.2 a20/15 - w50/- (b) (E) kPa 12.3 21.1 29.1 a20/15 - w45/40 (c) (E) kW 2.6 3.4 4.11 a20/15 - w45/40 (c) l/h 449 590 712 a20/15 - w45/40 (c) (E) kPa 14.3 23.5 33.3 (E) W 6 13 26 (E) dB(A) 39 46 50 (d) dB(A) 30 41 46 (f) m3/h 460 610 765 l 1.94 bar 10 inch Eurocone 3/4 V/ph/Hz 230/1/50 kW 0.45 kW 0.8 l 0.57 1400 02056 02071 Lower Middle High 3.05 3.78 4.45 2.14 2.69 3.20 525.6 652.4 769.9 19 27.8 37.2 3.61 4.53 5.50 525.6 652.4 769.9 16.2 23.7 31.7 3.07 3.87 4.70 527.1 663.4 803.9 17.1 25.8 35.5 6 13 26 38 49 54 30 41 46 460 610 765 2.33 10 Eurocone 3/4 230/1/50 0.45 0.8 0.57 1600 02057 02072 Lower Middle High 3.28 4.09 4.85 2.30 2.90 3.50 565.2 706 839.2 20.9 30.8 41 3.85 4.87 5.90 565.2 706 839.2 19.4 28.6 35.7 3.28 4.16 5.05 563.1 713 863.6 20.2 30.8 38.8 6 15 29 39 50 55 31 42 47 490 655 820 2.5 10 Eurocone 3/4 230/1/50 0.5 0.9 0.57 SLIR ONLY The above services refer to the following operating conditions: (a) Cooling mode at standard conditions: air temperature 27°C b.s. 19°C b.u., water inlet temperature 7°C, water outlet temperature 12°C (b) Heating mode conditions of use 1: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 50°C, water flow equal to the cooling water standard condition (c) Heating mode standard conditions: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 45°C, water outlet temperature 40°C (d) Sound pressure level valid for closed rooms with a volume of 100 m3 with a reverberation time of 0.5 s and installation on the floor/ceiling, sound emission on 1/4 sphere at 3 m distance (E) Eurovent certified data (f) Air flow rate measured with clean filters HYDRAULICS KIT CONTROLS ACCESSORIES B0872 B0873 B0736 B0921 B0633 B0832 B0834 B0205 B0204 B0200 B0201 B0203 B0894 B0954 B0959 On-board autonomous flat touch control kit Electronic contacts/0-10V remote control kit Wall-mounted Modbus chrono-thermostat kit Contact touch wall-mounted thermostat kit LH-RH connection rotation extension kit 2-way valve group kit with 4-wire actuator 3-way valve group kit with 4-wire actuator Manual 2-way valve group kit Manual 2-way valve insulation kit Adapter connection kit for 1/2" gas thread Adapter connection kit for 3/4" gas thread Eurokonus 90° bending connection kit Formwork for recessed installation Radiant closing panel RAL 9003 Closing panel RAL 9003 SLI SLIR 1100 1100 1100 1100 KIT FOR RECESS WITHOUT FORMWORK B0880 B0880 B0881 B0882 B0882 B0883 B0888 B0888 B0889 B0890 B0890 B0891 B0892 B0892 B0893 Air delivery grille with airfoil profile Air delivery grille with airfoil profile Air delivery grille with airfoil profile Air intake grille with airfoil profile Air intake grille with airfoil profile Air intake grille with airfoil profile Intake kit Intake kit Intake kit Telescopic top delivery plenum Telescopic top delivery plenum Telescopic top delivery plenum Insulated 90° delivery plenum Insulated 90° delivery plenum Insulated 90° delivery plenum SLI SLIR 1100 1400 1600 1100 1400 1600 1100 1400 1600 1100 1400 1600 1100 1400 1600 KIT FOR RECESS WITH FORMWORK Optional accessory | Accessory not compatible Accessory description on page 92 Please note that optional accessories are available for purchase in conjunction with all models of the terminal. When compatibility is only possible with certain sizes or models, the information is shown in the table. 86 Catalogue 2024 | January edition 87 PORTABLES MONO AND MULTISPLIT UNICO HRV FAN COIL UNITS HEAT PUMPS BMS Ci2 WALL High-wall fan coil units Compatible with: PRO-POWER Maximum power 3.81 kW in cooling and 5.08 kW in heating mode. 3-WAY VALVE INCLUDED The terminal is equipped with an integrated 3-way valve for easy installation. FEATURES · Air Conditioning, Dehumidifying, Heating and Filtering · Available in two sizes · DC brushless motor · Equipped with a large motorised flap · Simple installation thanks to the flexible tubes supplied · Three-way valve · Remote control and wall-mounting brackets · Plastic shell · Removable front panel for easy maintenance · Contact for external On-Off (presence contact) · Contact for switching on/off of the external generator with 4-wire valve actuator · Minimum sound power only 39dB (A) LAYOUT, DIMENSIONS, WEIGHT 1200 1400 A mm 915 915 B B mm 290 290 C mm 230 230 Weight kg 12.7 12.7 A C INSTALLATION High-wall 88 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA 1200 LGW Wall S1 inverter 99283 Fan speed Lower Middle High Total power output in cooling mode a27/19 - w7/12 (a) (E) kW 2.39 2.59 2.70 Sensitive power output in cooling mode a27/19 - w7/12 (a) (E) kW 1.85 2.03 2.15 Fluid flow rate a27/19 - w7/12 (a) l/h 412.6 447.4 466.5 Water side head loss a27/19 - w7/12 (a) (E) kPa 25.4 28.6 31.6 Total power output in heating mode a20/15 - w50/- (b) (E) kW 2.63 3.03 3.29 Fluid flow rate a20/15 - w50/- (b) l/h 412.6 447.4 466.5 Water side head loss a20/15 - w50/- (b) (E) kPa 26.5 30.3 32.7 Total power output in heating mode a20/15 - w45/40 (c) (E) kW 1.86 2.02 2.12 Fluid flow rate a20/15 - w45/40 (c) l/h 442.2 479.7 503.6 Water side head loss a20/15 - w45/40 (c) (E) kPa 30.2 34.9 37.5 Absorbed power (E) W 10 11 13 Sound Power Lw (A) (E) dB(A) 39 42 44 Sound pressure Lp (A) (d) dB(A) 30 33 35 Air flow rate (f) m3/h 400 454 492 Battery water content l 0.5 Maximum operating pressure bar 16 Hydraulic fittings inch Eurocone 3/4 F Electrical power supply V/ph/Hz 220-240/1/50 Max static heating efficiency (50°C) kW - Max static heating efficiency (70°C) kW - Water content of the radiant panel l - 1400 99284 Lower Middle High 2.88 3.30 3.81 2.31 2.71 3.18 497.9 571.2 661.0 33.0 41.2 56.8 3.77 4.33 5.08 497.9 571.2 661.0 30.3 37.9 51.9 3.09 3.65 4.30 528.9 624.2 733.9 35.7 47.5 61.9 15 22 34 47 51 57 38 42 48 590 689 825 0.5 16 Eurocone 3/4 F 220-240/1/50 - - - The above services refer to the following operating conditions: (a) Cooling mode at standard conditions: air temperature 27°C b.s. 19°C b.u., water inlet temperature 7°C, water outlet temperature 12°C (b) Heating mode conditions of use 1: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 50°C, water flow equal to the cooling water standard condition (c) Heating mode standard conditions: air temperature 20°C b.s., 15°C b.u. max, water inlet temperature 45°C, water outlet temperature 40°C (d) Sound pressure level valid for closed rooms with a volume of 100 m3 with a reverberation time of 0.5 s and installation on the floor/ceiling, sound emission on 1/4 sphere at 3 m distance (E) Eurovent certified data (f) Air flow rate measured with clean filters CONTROLS ACCESSORIES LGW B0856 Electronic wall-mounted control kit Optional accessory Accessory description on page 92 HRV UNICO MONO AND MULTISPLIT PORTABLES Please note that optional accessories are available for purchase in conjunction with all models of the terminal. When compatibility is only possible with certain sizes or models, the information is shown in the table. Catalogue 2024 | January edition 89 FCU accessories Download Additional information on these accessories Controls INDRZ Addressing of the Modbus control kit Factory mandatory addressing of the remote control kits (TR), in case of management via Modbus connection with SiOS Control, Bticino MyHome and any other home automation/BMS system communicating in Modbus. B0872 On-board autonomous flat touch control kit Backlit display with desired temperature display, real-touch buttons, selection of the operating mode and ventilation speed. Command with adjustable room thermostat, operating modes (ventilation, summer, winter, automatic) and ventilation programme (silent, auto, maximum, night), minimum water probe function. It has one input for the contact presence sensor connection and two 230VAC outputs for the control of 2 solenoid valves. Through the user interface it is possible to add a correction on the read room temperature. Remote control included. Can be remotely controlled by combination of keys for connection with Modbus RS485 ASCII or RTU protocol. Combination with B0736 command, MyHome by Bticino and SiOS Control is always possible (mandatory pairing for use with Bi2 SLI and SLIR, in this case, remote control not working). Colour RAL 9003. Compatible with: Bi2 SMART S1 SL SLR Bi2 NAKED SLI SLIR B0873 Electronic contacts/0-10V remote control kit Electronic interface card for management and control via 0-10V analog input or contacts (for radiant fan coil units use the contact mode and check that the management system interfaced to the B0756 card supports the control logic of Olimpia Splendid radiant technology). It has a 230VAC output for control of a solenoid valve and a water probe inlet with the function of a minimum probe (for both modes of remote control). Can be combined with B0921 contact touch wall-mounted thermostat kit (not for radiant fan coil units) or with third party home automation/BMS systems that can be interfaced to contacts or via 0-10V signal. Colour RAL 9003. Compatible with: Bi2 SMART S1 SL SLR Bi2 NAKED SLI SLIR B0736 Wall-mounted Modbus chrono-thermostat kit For MODBUS, RS485 connection. Up to 30 units can be controlled. Selection of the desired temperature selection, operating mode, ventilation speed, manual/chrono-thermostat mode. Ambient probe inserted in the control. Backlit LCD display. Presence sensor contact. The control is equipped with a dual insulated 230V/12 VAC power supply transformer and a backup battery. Wall mounting with hole interaxis compatible with standard 503 formwork box. Can be combined with the controls TR, B0872 and SiOS Control. Compatible with: Bi2 AIR Bi2 SMART S1 SL SLR TR TR Bi2 WALL Bi2 NAKED SLW TR SLI SLIR B0921 Contact touch wall-mounted thermostat kit Digital thermostat with room probe, backlit display and touch buttons. Semi-recessed installation (15 mm out of the wall) in boxes with 60 mm round or square interaxis screws. Room temperature display, adjustment of the desired room temperature from 5°C to 35°C, setting of the "cooling" or "heating" mode, setting of the fan speed (Min/Med/Max). 230V AC power supply, it has a solenoid valve output and a water temperature probe input. Can be paired with AR and B0873 remote control cards. Compatible with: Bi2 AIR Bi2 SMART S1 SL SLR AR Bi2 WALL Bi2 NAKED SLW AR SLI SLIR Optional accessory | Accessory not compatible Nota bene: gli accessori compatibili opzionabili sono acquistabili in abbinamento a tutti i modelli del terminale. Quando la compatibilità è possibile solo con alcune taglie o modelli, l'informazione è riportata in tabella. 90 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV B0856 Electronic wall-mounted control kit Equipped with LCD screen, mode control, control of the fan speed and room temperature. Compatible with: LGW Ci2 WALL COMPATIBILITY WITH CONTROLS FROM OTHER MANUFACTURERS To expand the control possibilities, the Olimpia Splendid terminal units are compatible with a selection of thermostats and advanced control systems, featuring wireless connections and applications for tablets and smartphones. You can consult the compatibility sheets in the download area of the Olimpiasplendid.it website. Electrical kits B0633 LH-RH connection rotation extension kit Electrical connection cable of the power supply and motor sensor for the installation of fan coil units in which the position of the hydraulic connection is rotated from left to right. Compatible with: Bi2 SMART S1 SL SLR Bi2 NAKED SLI SLIR B0839 LH-RH connection rotation extension kit Electrical connection cable of the power supply and motor sensor for the installations in which the position of the hydraulic connection is rotated from left to right. Compatible with: Bi2 AIR SL SLR Condensation drain kit B0983 NEW Condensation pump kit The optional kit for condensation pump allows solving the drain problem even where the slopes do not allow a natural discharge of the water (see details in the installation manual). Compatibile con: Bi2 WALL SLW 1000 UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 91 Hydraulics kit B0832 2-way valve group kit with 4-wire actuator It consists of a valve (with thermoelectric actuator and limit switch) and a lockshield. The former allows the control of the thermal emission of the fan coil unit by intercepting the passage of the water; the lockshield allows the balancing of the load losses of the system. This kit becomes mandatory in the SLR version except in the case where a 3-way valve kit is used or if there is a manifold with thermoelectric heads. Please note: for all terminal models, if wall-mounted thermostats are not used, the installation of 2- or 3-way valves is recommended for optimal cooling operation and for the on/off of a secondary circulator or heat generator. Compatible with: Bi2 AIR Bi2 SMART S1 SL SLR Bi2 NAKED SLI SLIR B0834 3-way valve group kit with 4-wire actuator It consists of a three-way valve switch (with thermoelectric actuator and limit switch) and a lockshield. The former allows the control of the thermal emission of the fan coil unit by intercepting the passage of the water; the lockshield allows the balancing of the load losses of the system; the by-pass maintains the circulation of the water in the system. This kit is an alternative to the 2-way solenoid valve kit (mandatory in the SLR version). Please note: for all terminal models, if wall-mounted thermostats are not used, the installation of 2- or 3-way valves is recommended for optimum cooling operation and for the on/off of a secondary circulator or heat generator. Compatible with: Bi2 AIR Bi2 SMART S1 SL SLR Bi2 NAKED SLI SLIR B0205 Manual 2-way valve group kit It consists of a valve and a lockshield, the former allows the fan coil to be excluded from the system manually, while the lockshield allows the balancing of the system load losses. Permitted if solenoid valves on the manifold are managed by the Bi2 control kit. Compatible with: Bi2 AIR Bi2 SMART S1 SL SLR Bi2 NAKED SLI SLIR B0204 Manual 2-way valve insulation kit Prevents condensation during the cooling operation (already included in the thermoelectric hydraulic kits). Compatible with: Bi2 AIR Bi2 SMART S1 SL SLR Bi2 NAKED SLI SLIR B0200 Adapter connection kit for 1/2" gas thread It allows the conversion of the 3/4" Eurokonus connection of the Bi2 into a standard 1/2" gas thread connection. Compatible with: Bi2 AIR Bi2 SMART S1 SL SLR Bi2 NAKED SLI SLIR B0201 Adapter connection kit for 3/4" gas thread It allows the conversion of the 3/4" Eurokonus connection of the Bi2 into a standard 3/4' gas thread connection. Compatible with: Bi2 AIR Bi2 SMART S1 SL SLR Bi2 NAKED SLI SLIR B0203 Eurokonus 90° bending connection kit Facilitates connection in case of hydraulic connections with wall-mounted pipes. Compatible with: Bi2 AIR Bi2 SMART S1 SL SLR Bi2 NAKED SLI SLIR Optional accessory | Accessory not compatible Please note that optional accessories are available for purchase in conjunction with all models of the terminal. When compatibility is only possible with certain sizes or models, the information is shown in the table. 92 Catalogue 2024 | January edition BMS Aesthetic kits Floor mounting bracket kit Kit for support brackets and floor mounting of the fan coil unit (glass front applications or on non-load-bearing walls). It also has the function of aesthetic kit for covering (white colour RAL 9003) and is therefore not compatible with the aesthetic kit of feet for covering. B0852 B0938 Compatible with: Bi2 AIR Bi2 SMART S1 SL SLR 1000 1000 HEAT PUMPS FAN COIL UNITS HRV Floor mounting bracket kit Kit for support brackets and floor mounting of the fan coil unit (glass front applications or on non-load-bearing walls). To be used in conjunction with the B0874 kit. Increases the fan coil unit depth by 17 mm (18 mm if with back panel) Compatible with: B0875 Bi2 AIR SL SLR 1100 1100 Aesthetic kit feet for covering Aesthetic kit containing two feet for covering any pipes coming from the floor. Available in the colour white RAL 9003. Compatible with: B0853 B0874 Bi2 AIR Bi2 AIR SL SLR 1000 1000 1100 1100 B0937 Bi2 SMART S1 SL SLR Aesthetic ceiling feet kit Aesthetic kit containing two feet for covering any pipes coming from the wall. Specially designed to maximise the space available for the pipes in the case of ceiling installation. Available in white RAL 9003. Compatibile con: B0982 NEW Bi2 SMART S1 SL SLR Back panel In white painted sheet metal (RAL 9003), for glass front applications. Compatible with: B0847 B0848 B0849 B0850 B0851 OUT B0876 B0876 B0877 Bi2 AIR Bi2 AIR Bi2 AIR Bi2 AIR Bi2 AIR Bi2 AIR Bi2 AIR Bi2 AIR SL SLR 200 200 400 400 600 600 800 800 1000 1000 1100 1100 1400 1400 1600 1600 Ceiling-mount kit (condensation trap) Trap kit for the collection of the condensation in case of horizontal installation. Compatible with: B0520 B0521 B0522 B0523 B0524 OUT B0878 B0878 B0879 Bi2 AIR - Bi2 SMART S1 Bi2 AIR - Bi2 SMART S1 Bi2 AIR - Bi2 SMART S1 Bi2 AIR - Bi2 SMART S1 Bi2 AIR - Bi2 SMART S1 Bi2 AIR Bi2 AIR Bi2 AIR SL SLR 200 400 600 800 1000 1100 1400 1600 Catalogue 2024 | January edition 93 UNICO MONO AND MULTISPLIT PORTABLES Kit for recess Formwork for recessed installation Frame for vertical recessed installation (to be combined with the closing panel). Compatible with: B0568 B0569 B0570 Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 200 200 400 400 600 600 B0571 B0894 Bi2 NAKED Bi2 NAKED SLI 800 1100 SLIR 800 1100 Radiant closing panel RAL 9003 Aesthetic panel for recessed radiant closing for vertical installation (mandatory kit, to be combined with the recessed formwork). Colour white RAL 9003. Compatible with: B0950 B0951 B0952 Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 200 400 600 B0953 B0954 Bi2 NAKED Bi2 NAKED SLI SLIR 800 1100 Closing panel RAL 9003 Aesthetic panel for recessed closing for vertical installation (to be combined with the recessed formwork). Colour white RAL 9003. Compatible with: B0955 B0956 B0957 Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 200 400 600 B0958 B0959 Bi2 NAKED Bi2 NAKED SLI SLIR 800 1100 Air delivery grille with airfoil profile Kit for recessed false ceiling mounting. Compatible with: B0550 B0551 B0552 B0553 Bi2 NAKED Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 200 400 600 800 Air intake grille with airfoil profile Kit for recessed false ceiling mounting. B0880 B0880 B0881 Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 1100 1400 1600 Compatible with: B0559 B0560 B0561 B0562 Bi2 NAKED Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 200 400 600 800 B0882 B0882 B0883 Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 1100 1400 1600 Optional accessory | Accessory not compatible Please note that optional accessories are available for purchase in conjunction with all models of the terminal. When compatibility is only possible with certain sizes or models, the information is shown in the table. 94 Catalogue 2024 | January edition BMS HEAT PUMPS Intake kit Kit for false ceiling or roof hatch mounting. Not compatible with recessed frame. Channels the intake air from the intake grille to the fan coil. Compatible with: B0194 B0195 B0196 B0197 Bi2 NAKED Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 200 400 600 800 B0888 B0888 B0889 Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 1100 1400 1600 Telescopic top delivery plenum Not compatible with recessed frame. Channels the air from the fan coil to the delivery grille. Compatible with: B0160 B0161 B0162 B0163 Bi2 NAKED Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 200 400 600 800 B0890 B0890 B0891 Bi2 NAKED Bi2 NAKED Bi2 NAKED Insulated 90° delivery plenum Not compatible with recessed frame. Channels the air from the fan coil to the delivery grille. SLI SLIR 1100 1400 1600 Compatible with: B0165 B0166 B0167 B0168 Bi2 NAKED Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 200 400 600 800 B0892 B0892 B0893 Bi2 NAKED Bi2 NAKED Bi2 NAKED SLI SLIR 1100 1400 1600 FAN COIL UNITS HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 95 SITALI Decentralised and ducted heat recovery ventilation units Indoor air quality. The importance of the introduction of outdoor air Heat Recovery Ventilation: many advantages for indoor comfort The most authoritative exponents of the scientific community agree on the importance of the introduction of outdoor air indoors, to increase the quality of indoor air. The greater the quantity of external air introduced into closed environments, the lower the concentration of pollutants and pathogens. A change of air carried out through the opening of the windows may not always be possible (for example in summer and winter) or sufficient: the quantity of air introduced is in fact not controllable or its uniform distribution. If there are HRV systems, the experts therefore recommend activating their continuous operation (7/7 days and H24) and increasing the exchange flow rate as much as possible. 98 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV UNICO High-efficiency and comfort decentralised and centralised systems Diversified solutions for each project To meet the needs of every room, Olimpia Splendid's Sitali range includes both decentralised and centralised units. Recommended for existing buildings, ad hoc solutions do not require any air distribution system or invasive installation work. For buildings where it is possible to design and implement a distribution system complete with ducts and terminals, however, the installation of centralised units is recommended. All the solutions for centralised systems include a PPE structure with sheet metal finish and plastic fittings. They are fitted with high-performance, energy-saving EC brushless motors. The centralised machines are fitted with G4 filters (ISO Coarse 60%) to protect the exchanger and for some sizes, it is possible to use F7 filters (ISO ePM1 60%) for improved air filtering on input. Thanks to the heat recovery unit, it is possible to transfer the heat of the air extracted from inside the rooms to the fresh air supplied from the outside, limiting the activation of the heating system and improving the building's energy performance. MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 99 heat recovery ventilation Decentralised systems SITALI SFE 100 S1 Continual single flow HRV SITALI SF 150 S1 Alternating single-flow HRV 100 150 NEW Sitali SFE 100 S1 (99231) Sitali SF 150 S1 (99299) Centralised systems 120 180 280 400 550 SITALI CX 120 Double flow HRV with vertical ore reversible installation AUTOMATIC CONTROLS Sitali CXRA 120 (99250) Sitali CXVA 120 (99249) SITALI CX 180 Double flow HRV with horizontal installation AUTOMATIC CONTROLS MANUAL CONTROLS SITALI CX 280 Double flow HRV with vertical installation AUTOMATIC CONTROLS MANUAL CONTROLS Sitali CXOA 180 (99248) Sitali CXOM 180 (99247) Sitali CXVA 280 (99246) Sitali CXVM 280 (99245) SITALI CX 400 Double flow HRV with vertical installation AUTOMATIC CONTROLS Sitali CXVA 400 (99244) SITALI CX 550 Double flow HRV with vertical installation AUTOMATIC CONTROLS Sitali CXVA 550 (99243) 100 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS SITALI SFE 100 S1 1 23 4 5 Decentralised nomenclature Valid for decentralised systems Position 1: Line name Sitali Position 2: Flow (SF=Single flow) Position 3: Type (E=Extractor) Position 4: Hole diameter (mm) Position 5: Series (S1, S2, S3 etc.) SITALI CXRA 120 1 2345 6 Centralised nomenclature Valid for ducted systems Position 1: Line name Sitali Position 2: Type (C=Centralised) Position 3: Flow (X=Crossed) Position 4: Installation (R=Reversible, V=Vertical, O=Horizontal) Position 5: Controls (A=Automatic, M=Manual) Position 6: Air flow rate HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 101 SITALI SF 150 S1 Decentralized Heat Recovery Ventilation with alternate single flow Compatible with: SILENT FUNCTION The most silent: only 10 -dB (A) Optimized for continuous 24/24h operation. INTELLIGENT FUNCTION Thanks to the presence of the temperature detection probe, the air flow inversion time is self-adjusted to allow the best comfort indoors. MAGNETIC FUNCTION Quick release via magnets for easy maintenance without the need for specialized staff. FEATURES · Temperature probe that adjusts the air flow inversion times to maintain the indoor comfort level · Energy class: · EC brushless motor · Integrated humidity sensor · Easy maintenance, indoor magnetic release · Infra-red remote control with LCD · Double filter on the inner/outer side of the exchanger · Multicolor LED indicator · 5 ventilation speeds available · Magnetic wall support for remote control · ON/OFF contact · Synchronization possible for up to 10 units (via cable connection) DIMENSIONS AND TECHNICAL SPECIFICATIONS 218 77,5 300÷570 TECHNICAL DATA PRODUCT CODE Hole diameter mm Energy class Air flow rate m³/h Sound level* dB(A) Absorption W Max thermal efficiency Max room temperature °C Weight kg Degree of protection IP M² treated** m² SF 150 S1 160 60/50/40/30/20 29/24/20/14/10 6/4,5/3,5/2,5/2 82% -20°C +50°C 5,5 IPX4 20 m² 158 ø 220-240 V ~ 50-60Hz aeraulic performance measured according to ISO 5801 at 230V 50Hz, air density 1.2 Kg/m3 - data measured in TÜV Rheinland accredited laboratory * sound pressure level at 3m in free field **Maximum treated area for civil dwellings (regulatory reference UNI 10339:1995) considering 30 m3/h as the maximum flow rate, being of alternate flow. Teulbeosctoepleicscpoipeico adaptttaabilleetaolltohe wall sthpiecsksnoersesdella parete FAinlttrio-daunstipfioltlevreereasfailcyilmente removaibbile aenldavwaabsihleable MSgaagnnceitoicmrealgeanseetifcoor epaesryfacilitare mleaoipneteranzainocnei dinitmervaennuttieonzsione GExritgelrinaaelsgtreilrlnea 102 SRceagmenbeiraattoivre dhiecaatlore reixgcehnaenrgateirvwoictohn pacco cwearsahmaibcloe lcaevrambiliec pack FCropnrtifcrovnetrailne in hAiBgSh-dqiuaalltiatyqAuBalSità UVennitiàlavteinngtiluannite Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS SITALI SFE 100 S1 Decentralized Heat Recovery Ventilation with continuous single flow. Compatible with: SILENT FUNCTION The most silent: only <9dB(A). Optimized for continuous 24/24h operation. AIR EXCHANGE Decentralized HRV unit with continuous single flow, Ø100 mm, with very low energy consumption, for replacing stale air in the humid environments with maximum acoustic comfort. Ideal for preventing problems of condensation and mould, which inevitably damage the structure and compromise the health of the occupants. HUMIDITY DETECTION The unit is equipped with a humidity detection probe which works in automatic mode. If there is a sudden increase in the humidity rate and the relative humidity value exceeds 65% the unit works at intermediate speed and after the humidity level stabilises, it continues to work at intermediate speed for a fixed time of 5 minutes. The humidistat function can be activated via dip switch. ø 99 FEATURES · Top quality ABS structure · High-efficiency aerodynamic fan · EC brushless motor with thermal protection · Integrated humidity sensor (see manual for operation) · Automatic timer with shutdown delay (see manual for operation). · Elegant design with minimalist lines DIMENSIONS AND TECHNICAL SPECIFICATIONS 164 116 70 4C6 · Front cover; easy to remove for cleaning, without the use of tools · Aerodynamic deflectors · Very low energy consumption · 3 ventilation speeds available TECHNICAL DATA PRODUCT CODE Hole diameter mm Air flow rate m³/h Absorption W Sound level* dB(A) Max room temperature °C Degree of protection IP (wall installation) Weight kg M² treated** 99231 100 (110 with telescopic tube) max 102 - min 17 max 4,5 - min 0,9 max 37 - min 9 40 IPX4 0,6 8 m² 220-240 V ~ 50-60Hz aeraulic performance measured according to ISO 5801 at 230V 50Hz, air density 1.2 Kg/m3 - data measured in TÜV Rheinland accredited laboratory * sound pressure level at 3m in free field **Maximum treated area for civil dwellings (regulatory reference UNI 10339:1995) considering 90 m3/h as max flow rate, 10 Pa prevalence and a room height of 2.7 m. HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 103 SITALI CX 120 Double flow centralised compact HRV Compatible with: COMPACT DIMENSIONS The compact size makes the units each to install in any room. FLEXIBLE INSTALLATION The reversible CXRA version can be installed on the wall in a vertical position, and horizontal position on the ceiling or false ceiling (the CXVA version can only be installed in the vertical position). AUTOMATIC CONTROLS Multi-function control panel. FEATURES OPERATION · External panels made of pre-coated RAL 9010 and made of galvanized steel. · Main structure made of expanded polypropylene to reduce thermal bridges, noise emission and to ensure maximum seal. · Energy-efficient external rotor EC motors. Featuring thermal protection and mounted on ball bearings for long service life. · Ultra-quiet and high-performance centrifugal fan with backward-curved blades coupled directly and dynamically balanced to the motor. · Cross-flow, counterflow heat exchanger with high efficiency. · The pre-wired unit makes electrical connection easy. · ISO Coarse 60% (G4) filters easily removable from the outside: no need to remove the access panel to perform maintenance operations. ISO ePM1 60% (F7) filter on request. · Integrated condensation drain. · Automatic frost protection prevents the formation of ice on the inlet side of the heat exchanger. · The unit is supplied with a multi-function control panel, with the following control and connection options: · 3-speed setting option (to be set during installation) · BOOST activation · Reset filter · On/off · Keypad lock · Anti-frost activation indicator · Fault indicator · Filter replacement indicator · Connection to remote room sensors (humidity, CO2, etc.) · Modbus interface. LAYOUT, DIMENSIONS, WEIGHT Sitali CXRA 120 Sitali CXVA 120 F C BA H C 104 FG D E D F E A B G A B C D E F G H Weight SITALI CXRA SITALI CXVA 120 120 mm 504 504 mm 559 553 mm 34 34 mm 741 746 mm 34 29 mm 97 97 mm 171 171 mm 190 - kg 11,5 kg 11,5 kg Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Maximum flow rate @100 Pa Electrical power consumption (at the maximum flow rate) SEC class (local demand control) SEC class (central demand control) SEC class (manual control - No demand control ventilation) Thermal efficiency Reference flow rate Reference pressure difference Specific power consumption (SPI) Sound power level (LWA) Electrical power supply IP protection rating Sound pressure @3m(1) Max room temperature m3/h W % m3/h Pa W/m3/h dB(A) dB(A) °C (1) Sound pressure level at 3m in free field, of the casing, speed 40%, indicated only for comparison purposes. SITALI CXRA 120 99250 8021183992502 91 58 82 64 50 0.391 50 220-240V~/50-60Hz IPX4 18 +40 SITALI CXVA 120 99249 8021183992496 102 58 82 71 50 0.352 50 220-240V~/50-60Hz IPX4 18 +40 SITALI CXRA 120 480 SITALI CXVA 120 480 400 400 320 320 240 240 160 5 4 5 160 4 80 1 3 2 80 1 3 2 0 0 25 50 75 100 125 150 3 0 0 25 50 75 100 125 150 3 1 20 2 40 3 60 4 80 5 100 3 9 22 13 48 20 71 32 96 56 114 Inlet curves in accordance with European regulation 1253/2014 (Er P) 1 20 2 40 3 60 4 80 5 100 3 9 22 13 48 20 71 32 96 58 124 Sitali CXRA 120 Sitali CXVA 120 1. Air inlet from exterior 2. Air expulsion to exterior 3. Air supplied to interior 4. Air extracted from interior 5. Condensation drain HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 105 SITALI CX 180 Double flow centralised HRV Compatible with: INTEGRATED PHYSICAL BYPASS Ideal for "free cooling" operation during the summer HORIZONTAL INSTALLATION Ideal for installation the ceiling or false ceilings, in a horizontal position. MANUAL OR AUTOMATIC CONTROLS Sitali COAX 180 features a multi-function control panel with LCD display (see image on the side). Sitali COVID 180 does not have controls and must be combined with an S-type control (simplified, one of codes B1061, B1062, B1063). FEATURES OPERATION · External frame made of pre-coated RAL 9010 galvanized steel. · Internal structure made of expanded polypropylene to reduce thermal bridges, noise emission and to ensure maximum seal. · Energy-efficient external rotor EC motors. Featuring thermal protection and mounted on ball bearings for long service life. · Ultra-quiet and high-performance, balanced centrifugal fan with backward- curved blades coupled directly and dynamically balanced to the motor. · Cross-flow, counterflow heat exchanger with high efficiency. · Simplified electrical connection: the unit is supplied pre-wired. · ISO Coarse 60% (G4) filters easily removable from the outside: no need to remove the access panel to perform maintenance operations. ISO ePM1 60% filter (F7) on request. · Automatic frost protection preventing ice formation on the inlet side of the heat exchanger. · Double condensation drain that can be used based on climatic requirements. Version with CX0A 180 automatic control · 3-speed setting and selection. · Boost function. · Holiday and Night Mode function. · Weekly programming. · By-pass control · Air flow balancing. · Filter maintenance and fault indicator. · Hour count indicator · Settings savings and uploading. · Connection to remote room sensors (humidity, CO2, etc.) · ModBus interface. · Connection to electric heating element before and after the ventilation unit. · Connection to water heating coil Version with COVID 180 manual control · Three-speed operation with simplified external S-type control, which also allows manual activation of the bypass. LAYOUT, DIMENSIONS, WEIGHT G H SITALI CXOA SITALI CXOM 180 180 A mm 574 574 H AB B mm 648 648 C mm 738 738 D mm 1037 1037 C D E mm 125 125 F mm 66 66 E I F E G mm 123 123 H mm 240 240 F I mm 270 270 Weight kg 20 kg 20 kg 106 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Maximum flow rate @100 Pa Electrical power consumption (at the maximum flow rate) SEC class (local demand control) SEC class (central demand control) SEC class (manual control - No demand control ventilation) Thermal efficiency Reference flow rate Reference pressure difference Specific power consumption (SPI) Sound power level (LWA) Electrical power supply IP protection rating Sound pressure @3m(1) Max room temperature m3/h W % m3/h Pa W/m3/h dB(A) dB(A) °C (1) Sound pressure level at 3m in free field, of the casing, speed 40%, indicated only for comparison purposes. SITALI CXOA 180 99248 8021183992489 177 105 82 124 50 0.412 50 220-240V~/50-60Hz IPX4 21 +40 SITALI CXOM 180 99247 8021183992472 177 105 82 124 50 0.412 50 220-240V~/50-60Hz IPX4 21 +40 Static pressure - Pa SITALI CXOA 180 500 450 400 350 300 250 200 150 3 100 2 50 1 0 0 20 40 60 5 4 80 100 120 140 160 180 200 220 Air flow - m3/h Speed % 1 20 2 40 3 60 4 80 5 100 W max 10 18 36 77 105 m3/h max 24 67 117 178 209 Inlet curves in accordance with European regulation 1253/2014 (Er P) Static pressure - Pa SITALI CXOM 180 500 450 400 350 300 250 200 150 D 100 B 50 A 0 0 20 40 60 G F 80 100 120 140 160 180 200 220 Air flow - m3/h Trimmer Position A B C D E F G Speed % 20 40 53 60 70 80 100 W max 10 18 28 36 47 68 105 m3/h max 24 67 100 117 139 168 209 TRIMMER D C E B F A G 1. Air inlet from exterior 2. Air expulsion to exterior 3. Air supplied to interior 4. Air extracted from interior (Winter condensation drain) (Summer condensation drain) HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 107 SITALI CX 280 Double flow centralised HRV Compatible with: INTEGRATED PHYSICAL BYPASS Ideal for "free cooling" operation during the summer VERTICAL INSTALLATION Suitable for wall installation in a vertical position. MANUAL OR AUTOMATIC CONTROLS Sitali CXVA 280 features a multi-function control panel with LCD display (see image on the side). Sitali CXVM 280 does not have controls and must be combined with an S-type control (simplified, one of codes B1061, B1062, B1063). FEATURES OPERATION · External frame made of pre-coated RAL 9010 galvanized steel. · Internal structure made of expanded polypropylene to reduce thermal bridges, noise emission and to ensure maximum seal. · Energy-efficient external rotor EC motors. Featuring thermal protection and mounted on long-lasting ball bearings. · Ultra-quiet and high-performance, balanced centrifugal fan with backward- curved blades coupled directly and dynamically balanced to the motor. · Cross-flow, counterflow heat exchanger with high efficiency. · Simplified electrical connection: the unit is supplied pre-wired. · Removable front panel for access to the filters and exchanger. · Supplied with easily removable ISO Coarse 60% (G4) filters. ISO ePM1 55% filter (F7) on request. · Automatic frost protection preventing ice formation on the inlet side of the heat exchanger. · Double condensation drain that can be used based on climatic requirements. · Left or right configuration for flexible installation Version with CXVA 280 automatic control · 3-speed setting and selection. · Boost function. · Holiday and Night Mode function. · Weekly programming. · By-pass control · Air flow balancing. · Filter maintenance and fault indicator. · Hour count indicator · Settings savings and uploading. · Connection to remote room sensors (humidity, CO2, etc.) · ModBus interface. · Connection to electric heating element before and after the ventilation unit. · Connection to water heating coil Version with CXVM 280 manual control · Three-speed operation with simplified external S-type control, which also allows manual activation of the bypass. LAYOUT, DIMENSIONS, WEIGHT E D G H I I H J K L G 108 F A B C A B C D E F G H I J K L Weight SITALI CXVA SITALI CXVM 280 280 mm 610 610 mm 665 665 mm 298 298 mm 592 592 mm 125 125 mm 55 55 mm 227 227 mm 276 276 mm 89 89 mm 90 90 mm 104 104 mm 104 104 kg 21,4 kg 23 kg Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Maximum flow rate @100 Pa Electrical power consumption (at the maximum flow rate) SEC class (local demand control) SEC class (central demand control) SEC class (manual control - No demand control ventilation) Thermal efficiency Reference flow rate Reference pressure difference Specific power consumption (SPI) Sound power level (LWA) Electrical power supply IP protection rating Sound pressure @3m(1) Max room temperature m3/h W % m3/h Pa W/m3/h dB(A) dB(A) °C (1) Sound pressure level at 3m in free field, of the casing, speed 40%, indicated only for comparison purposes. SITALI CXVA 280 99246 8021183992465 256 160 83 179 50 0.385 56 220-240V~/50-60Hz IPX2 27 +40 SITALI CXVM 280 99245 8021183992458 256 160 83 179 50 0.385 56 220-240V~/50-60Hz IPX2 27 +40 Static pressure - Pa SITALI CXVA 280 600 550 500 450 400 350 5 300 250 4 200 3 150 100 2 50 1 0 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Air flow - m3/h Speed % 1 20 2 40 3 60 4 80 5 100 W max 13 25 51 98 167 m3/h max 57 113 172 225 281 Inlet curves in accordance with European regulation 1253/2014 (Er P) Static pressure - Pa SITALI CXVM 280 600 550 500 450 400 350 G 300 250 F 200 D 150 100 B 50 A 0 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Air flow - m3/h Trimmer Position A B C D E F G Speed % 20 40 53 60 70 80 100 W max 13 17 25 41 51 100 167 m3/h max 57 88 113 153 172 225 281 TRIMMER D C E B F A G 1. Air expulsion to exterior 2. Air inlet from exterior 3. Air extracted from interior 4. Air supplied to interior (Winter condensation drain) (Summer condensation drain) LH flow direction HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 109 SITALI CX 400 Double flow centralised HRV Compatible with: INTEGRATED PHYSICAL BYPASS Ideal for "free cooling" operation during the summer VERTICAL INSTALLATION Suitable for wall installation in a vertical position. AUTOMATIC CONTROL The unit is supplied with a multi-function control panel and LCD display. FEATURES OPERATION · External frame made of pre-coated RAL 9010 galvanized steel. · Internal structure made of expanded polypropylene to reduce thermal bridges, noise emission and to ensure maximum seal. · Energy-efficient external rotor EC motors. Featuring thermal protection and mounted on ball bearings for long service life. · Ultra-quiet and high-performance, balanced centrifugal fan with backward- curved blades coupled directly and dynamically balanced to the motor. · Cross-flow, counterflow heat exchanger with high efficiency. · Simplified electrical connection: the unit is supplied pre-wired. · ISO Coarse 60% (G4) filters easily removable from the outside. The unit is also fitted with an ISO ePM1 60% filter (F7) on the air inlet. · Automatic frost protection preventing ice formation on the inlet side of the heat exchanger. · Double condensation drain that can be used based on climatic requirements. · Left or right configuration for flexible installation · 3-speed setting. · Boost function. · Holiday and Night Mode function. · Weekly programming. · Bypass control. · Air flow balancing. · Filter maintenance and fault indicator. · Operating hours counter. · Settings saving and upload. · Connection of remote room sensors (humidity, CO2, etc.) · ModBus interface. · Connection to electric heating element before and after the ventilation unit. · Water coil connection for heating. LAYOUT, DIMENSIONS, WEIGHT F F BC A J I J M N O L K L 110 D H E A B C D E F G H I J K L M N O Weight SITALI CXVA 400 mm 778 mm 799 mm 860 mm 525 mm 549 mm 148 mm 62 mm 23 mm 490 mm 144 mm 220 mm 279 mm 1225 mm 180 mm 222.5 kg 34,5 kg Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Maximum flow rate @100 Pa Electrical power consumption (at the maximum flow rate) SEC class (local demand control) SEC class (central demand control) SEC class (manual control - No demand control ventilation) Thermal efficiency Reference flow rate Reference pressure difference Specific power consumption (SPI) Sound power level (LWA) Electrical power supply IP protection rating Sound pressure @3m(1) Max room temperature m3/h W % m3/h Pa W/m3/h dB(A) dB(A) °C (1) Sound pressure level at 3m in free field, of the casing, speed 40%, indicated only for comparison purposes. SITALI CXVA 400 99244 8021183992441 363 160 86 254 50 0.268 52 220-240V~/50-60Hz IPX4 26 +40 Static pressure - Pa SITALI CXVA 400 500 450 400 350 300 250 200 150 100 50 0 0 5 4 3 2 1 50 100 150 200 250 300 350 400 450 Air flow - m3/h Inlet curves in accordance with European regulation 1253/2014 (Er P) Speed % 1 20 2 40 3 60 4 80 5 100 W max 10 22 48 90 160 m3/h max 84 162 243 322 403 1. Air expulsion to exterior 2. Air inlet from exterior 3. Air supplied to interior 4. Air extracted from interior (Winter condensation drain) (Summer condensation drain) LH flow direction HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 111 SITALI CX 550 Double flow centralised HRV Compatible with: INTEGRATED PHYSICAL BYPASS Ideal for "free cooling" operation during the summer VERTICAL INSTALLATION Suitable for wall installation in a vertical position. AUTOMATIC CONTROL The unit is supplied with a multi-function control panel and LCD display. FEATURES OPERATION · External frame made of pre-coated RAL 9010 galvanized steel. · Internal structure made of expanded polypropylene to reduce thermal bridges, noise emission and to ensure maximum seal. · Energy-efficient external rotor EC motors. Featuring thermal protection and mounted on long-lasting ball bearings. · Ultra-quiet and high-performance, balanced centrifugal fan with backward- curved blades coupled directly and dynamically balanced to the motor. · Cross-flow, counterflow heat exchanger with high efficiency. · Simplified electrical connection: the unit is supplied pre-wired. · Removable front panel for access to the filters and exchanger. · Supplied with ISO Coarse 60% (G4) filters that can be easily removed from the outside. The unit is also fitted with an ISO ePM1 60% filter (F7) on the air inlet. · Automatic frost protection preventing ice formation on the inlet side of the heat exchanger. · Double condensation drain that can be used based on climatic requirements. · Left or right configuration for flexible installation · 3-speed setting. · Boost function. · Holiday and Night Mode function. · Weekly programming. · Bypass control. · Air flow balancing. · Filter maintenance and fault indicator. · Operating hours counter. · Settings saving and upload. · Connection of remote room sensors (humidity, CO2, etc.) · ModBus interface. · Connection to electric heating element before and after the ventilation unit. · Water coil connection for heating. LAYOUT, DIMENSIONS, WEIGHT E F BC A D H G H J K L I 112 A B C D E F G H I J K L Weight SITALI CXVA 550 mm 778 mm 799 mm 860 mm 549 mm 148 mm 62 mm 490 mm 144 mm 220 mm 122.5 mm 180 mm 246.5 kg 44 kg Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Maximum flow rate @100 Pa Electrical power consumption (at the maximum flow rate) SEC class (local demand control) SEC class (central demand control) SEC class (manual control - No demand control ventilation) Thermal efficiency Reference flow rate Reference pressure difference Specific power consumption (SPI) Sound power level (LWA) Electrical power supply IP protection rating Sound pressure @3m(1) Max room temperature m3/h W % m3/h Pa W/m3/h dB(A) dB(A) °C (1) Sound pressure level at 3m in free field, of the casing, speed 40%, indicated only for comparison purposes. SITALI CXVA 550 99243 8021183992434 520 333 82 364 50 0.412 58 220-240V~/50-60Hz IPX4 34 +40 Static pressure - Pa SITALI CXVA 550 600 550 500 450 400 350 300 250 200 150 100 50 0 0 2 1 50 100 4 5 3 150 200 250 300 350 400 450 500 550 600 Air flow - m3/h Speed % 1 20 2 40 3 60 4 80 5 100 W max 17 44 110 264 333 m3/h max 110 221 330 440 550 Inlet curves in accordance with European regulation 1253/2014 (Er P) 1. Air expulsion to exterior 2. Air inlet from exterior 3. Air supplied to interior 4. Air extracted from interior (Winter condensation drain) (Summer condensation drain) LH flow direction HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 113 Decentralized HRV accessories B0838 External grille High-quality ABS fixed external grille, resistant to impacts and UV rays. Colour RAL 9010. Diameter 100mm. Compatible with Sitali SFE 100. Download Additional information on these accessories B0837 Telescopic pipe PVC telescopic pipe which adapts to the thickness of the wall. Diameter 100mm. Compatible with Sitali SFE 100. B1119 NEW Terminal unit 150 Silent "Dnew 45dB), designed to reduce noise coming from outside. Suitable for particularly windy outdoor conditions. Made of RAL9010 pre-painted aluminium sheet, equipped with fireproof sound-absorbing mat, front inspection panel, drip trap and anti-insect net. Possibility of semi-recessed installation as well. Compatible with Sitali SF 150 S1. Centralised HRV accessories External air distribution ABS ext grille High-quality ABS fixed external grille, resistant to impacts and UV rays. Colour RAL 9010. B1065 B1066 B1067 Diameter 100mm Diameter 125mm Diameter 150mm Flex ALU ISO Flexible pipe, 10m in length, made with aluminium/polyester/micro-perforated aluminium walls for air passage noise reduction and steel concertina wire. Polyester fibre thermal insulation coating (thickness 25mm/16kg/m3) and aluminium-coated polyolefin film outer protection. B1068 Diameter 127mm B1069 Diameter 160mm Wall passage Wall penetration kit with external terminal in galvanised sheet metal coated in RAL 9010 and fitted with soundabsorbing mat. B1074 Diameter 125mm B1075 Diameter 150mm Telescopic pipe PVC telescopic pipes which adapt to the thickness of the wall. (L=300-570 mm). B1103 B1104 B1105 Diameter 100mm Diameter 125mm Diameter 150mm EPE pipe Insulated and soundproofed EPE pipe, with smooth interior and exterior; length 2m. B1110 B1114 114 DN125 L=2m DN150 L=2m Catalogue 2024 | January edition BMS HEAT PUMPS EPE 90 bend Insulated and soundproofed EPE bend, with smooth interior and exterior. B1111 DN125 B1115 DN150 EPE coupling Coupling for connecting EPE pipe/EPE pipe, EPE pipe/EPE 90 bend. B1112 DN125 B1116 DN150 EPE collar Bracket collar and for connection of the EPE/ventilation unit pipe and EPE pipe/distribution plenum. B1113 DN125 B1117 DN150 Internal air distribution FAN COIL UNITS HRV UNICO E-I designer vent Extraction/inlet vent with flow rate adjustment module; front cover made of high-quality ABS; white RAL 9010. The adjustment module consists of removable concentric circles to define the desired volume of air. B1058 B1055 B1056 B1057 Diameter 80mm Diameter 100mm Diameter 125mm Diameter 150mm FT-WHITE grille Rectangular steel grille pre-coated in RAL 9010 white, with round perforated screen and magnetic attachment system. B1070 Dimension 200x100mm B1072 Dimension 300x100mm FT-METAL grille Rectangular steel grille with metallic finish, round perforated screen and magnetic attachment system. B1071 Dimension 200x100mm B1073 Dimension 300x100mm B1059 B1054 Flex HDPE 75/63 Flexible 75/63 pipe with antimicrobial, antibacterial and antistatic treatment, made with high-density double polyethylene wall; corrugated on the outside and smooth on the inside; supplied with end caps; used to channel the air from the distribution plenum to the air inlet and extraction vents. Suitable for installation in concrete slab, false ceilings or on walls. Length 50 m. FLEX HDPE 75/63 90° adaptor 90° angle adaptor, Ø125mm with 2 attachments Ø80mm (for Flex HDPE 75/63 duct), including 2 protection/end caps, length 250mm. Suitable for designer vents with 125mm diameter and extraction/inlet valves. MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 115 B1076 B1077 FLEX HDPE 75/63 hooks Connection kit for Flex HDPE 75/63 pipe to make worksite installation easier. Available in packs of 12 in red or blue to identify the air flow direction. Blue Red B1078 FLEX HDPE 75/63 90° bend 90° bend kit for Flex HDPE 75/63 pipe with sealing rings included. B1087 FLEX HDPE 75/63 coupling Coupling kit for Flex HDPE 75/63 pipe with sealing rings included. B1088 O-Ring FLEX HDPE 75/63 O-ring kit for Flex HDPE 75/63 pipe (pack of 10). B1095 Plenum P Ø125mm - 4 outlets (for Flex HDPE) Distribution plenum, 1 inlet Ø125mm, 4 outlets Ø80mm (for Flex HDPE 75/63 duct) and 5 protection/end caps supplied. B1096 Plenum P Ø125mm - 6 outlets (for Flex HDPE) Distribution plenum, 1 inlet Ø125mm, 6 outlets Ø80mm (for Flex HDPE 75/63 duct) and 7 protection/end caps supplied. B1094 Plenum P Ø125mm - 10 outlets (for Flex HDPE) Distribution plenum, 1 inlet Ø125mm, 10 outlets Ø80mm (for Flex HDPE 75/63 duct) and 11 protection/end caps supplied. B1098 Plenum P Ø150mm - 10 outlets (for Flex HDPE) Distribution plenum, 1 inlet Ø150mm, 10 outlets Ø80mm (for Flex HDPE 75/63 duct) and 11 protection/end caps supplied. B1099 Plenum P Ø150mm - 15 outlets (for Flex HDPE) Distribution plenum, 1 inlet Ø150mm, 15 outlets Ø80mm (for Flex HDPE 75/63 duct) and 16 protection/end caps supplied. B1092 Plenum L 200x100mm - 1 coupling (for Flex HDPE) Inlet/extraction plenum, 1 fitting on the long side Ø80mm, complete with anti-mortar closure and 1 cap (for Flex HDPE 75/63 duct). Air flow adjustment via the CAL80 damper (on request). B1093 Plenum L 300x100mm - 2 couplings (for Flex HDPE) Inlet/extraction plenum, 2 fittings on the long side Ø80mm, complete with anti-mortar closure and 2 caps (for Flex HDPE 75/63 duct). Air flow adjustment via the CAL80 damper (on request). 116 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS B1101 Plenum P 200x100mm - 1 coupling (for Flex HDPE) Inlet/extraction plenum, 1 rear fitting Ø80mm, complete with anti-mortar closure and 1 cap (for Flex HDPE 75/63 duct). Air flow adjustment via the CAL80 damper (on request). B1102 Plenum P 300x100mm - 2 couplings (for Flex HDPE) Inlet/extraction plenum, 2 fittings on the rear Ø80mm, complete with anti-mortar closure and 2 caps (for Flex HDPE 75/63 duct). Air flow adjustment via the CAL80 damper (on request). B1091 Plenum LCS 200x100mm - 1 coupling (for Flex HDPE) Inlet/extraction plenum, 1 fitting on the short side Ø80mm, complete with anti-mortar closure and 1 cap (for Flex HDPE 75/63 duct). B1089 Plenum L 140x140mm - 1 coupling (for Flex HDPE) Inlet/extraction plenum with 1 side coupling Ø80mm (for HDPE 75/63). Including anti-mortar closure and 1 protection/end cap. Dimension 140x140mm. Suitable for designer vents measuring 80 and 100mm in diameter. B1090 Plenum L 200x200mm - 2 couplings (for Flex HDPE) Inlet/extraction plenum with 2 side couplings Ø80mm (for HDPE 75/63). Including anti-mortar closure and 2 protection/end caps. Dimension 200x200mm. Suitable for designer vents measuring 125 and 150mm in diameter. B1097 Plenum P 140x140mm - 1 coupling (for Flex HDPE) Inlet/extraction plenum with 1 rear coupling Ø80mm (for HDPE 75/63). Including anti-mortar closure and 1 protection/ end cap. Suitable for designer vents measuring 80 and 100mm in diameter. B1100 Plenum P 200x200mm - 2 couplings (for Flex HDPE) Inlet/extraction plenum with 2 rear couplings Ø80mm (for HDPE 75/63). Including anti-mortar closure and 2 protection/end caps. Suitable for designer vents measuring 125 and 150mm in diameter. B1106 CAL80 damper Flow rate regulator damper, designed to be attached to the vents Ø80mm of the inlet/extraction plenum or distribution plenum, made of polypropylene, with quick-fit system, including wing-shaped fins to ensure maximum acoustic comfort. Pack of three. B1107 METAL EST 125 valve Valid for extraction in RAL 9010 coated steel, Ø125mm, manually and progressively adjustable. B1108 PP EST-MM 125 valve Valid for extraction/inlet in white PP, Ø125mm, manually and progressively adjustable. B1109 METAL IMM 125 valve Valid for inlet in RAL 9010 coated steel, Ø125mm, manually and progressively adjustable. HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 117 Remote controls B1061 Control-S 2 recessed modules Remote control for HRV unit with heat recovery, including 3 switches. Option to select 3 speeds and enable free-cooling mode. 230V~ 50/60Hz. B1062 Control-S 3 recessed modules Remote control for HRV unit with heat recovery, including 3 switches. Option to select 3 speeds and enable free-cooling mode. 230V~ 50/60Hz. Version for recessed installation with 3 modules suitable for box 503. B1063 Control-S wall installation Remote control for HRV unit with heat recovery, including 3 switches. Option to select 3 speeds and enable free-cooling mode. 230V~ 50/60Hz. Other accessories B1060 F7 filter box External cassette including F7 filter with galvanised metal sheet pre-coated with RAL 9010 and attachment with 125mm attachment. Suitable for CX 120, CX180 and CX28 F7 filters Class F7 filtration elements (pack of 1 item). B1079 B1081 B1083 B1085 For Sitali CX 120 For Sitali CX 180 For Sitali CX 280 For Sitali CX 400-550 G4 filters Class G4 filtration elements (pack of 2 items). B1080 B1082 B1084 B1086 For Sitali CX 120 For Sitali CX 180 For Sitali CX 280 For Sitali CX 400 - 550 118 Catalogue 2024 | January edition 119 PORTABLES MONO AND MULTISPLIT UNICO HRV FAN COIL UNITS HEAT PUMPS BMS AIR CONDITIONING UNICO Air conditioners and air-to-air heat pumps without outdoor unit A unique product. Also for production technology Patented in 1998 by Olimpia Splendid and produced, still today, in Italy, with the use of new natural, low-GWP and reclaimed refrigerants A cutting-edge production pavilion Since 1998 Unico has been produced in Italy, in the Olimpia Splendid factory, located in Brescia. A long story that details the important technological know-how acquired by the company in the production of air conditioners without outdoor units. An experience that has now been further enhanced, giving life to a cutting-edge production pavilion in the world of residential air conditioning, powered by 100 percent electricity from renewable sources and equipped with automated multi-gas lines-designed to safely handle low-GWP refrigerants. Natural, low GWP and regenerated coolant gases First residential air conditioner with 100% reclaimed gas, today Unico is also the first air conditioner without outdoor unit produced in Italy with R290 and R32 gas. The conversion to new refrigerants is for Olimpia Splendid a concrete commitment, taken personally, to be an active part in the creation of more sustainable home comfort solutions. 124 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV UNICO The widest and most diversified range Up to 3.5 kW of power. With different aesthetics, to meet every air conditioning need with a unique product Behind the range, a project 2 types of motors, 4 different refrigerant gases and multiple power sizes. The Unico range is the widest and most diversified on the market today, designed to meet the different installation needs residential and commercial - with a specific solution: unique. Behind every design, an Italian signature The collaboration between Olimpia Splendid and Italian designers - emerging or world-famous - has deep roots. The first design of Unico by King & Miranda was in 1998: an iconic product that inspired, in the following years, the projects of other important Italian brands: Sara Ferrari, Matteo Thun and Antonio Rodriguez, Ercoli+Garlandini and Newtone. An internationally awarded design recognised by the most prestigious competitions in the sector. MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 125 Air conditioners and heat pumps without an outdoor unit UNICO EVO The quietest INVERTER VERSION <2.0 kW Unico Evo NEW 20 HP PVAN (02453)* 2.1÷2.5 kW Unico Evo NEW 25 HP PVAN (02455)* UNICO AIR The slimmest UNICO EDGE The most versatile UNICO PRO The most powerful ON/OFF VERSION INVERTER VERSION ON/OFF VERSION INVERTER VERSION INVERTER VERSION Unico Air 8 SF (01503) Unico Air 8 HP (01504) Unico Air 20 SF EVA (02112)* Unico Air 20 HP EVA (02111)* Unico Air 25 HP EVA (02095)* Energy efficiency classes in cooling, outdoor ambient temperature DB 35°C / WB 24°C; indoor room temperature DB 27°C / WB 19°C. 126 BMS HEAT PUMPS FAN COIL UNITS 2.6÷3.0 kW Unico Edge 30 SF RFA (02132)* Unico Edge 30 HP RFA (02133)* Unico Edge 30 SF EVA (02116)* Unico Edge 30 HP EVA (02115)* Unico Pro NEW 30HP EVAN (02238)* 3.1÷3.5 kW Unico Pro NEW 35HP EVAN (02239)* 5678 New nomenclature Valid for products marked with * Position 1: Unique line name Position 2: Range Name (EVO, AIR, EDGE, PRO, TOWER) Position 3: Size (20, 25, 30, 35) 20=Class up to 2.0 kW of rated power in cooling 25=Class from 2.1 kW up to 2.5 kW of rated power in cooling 30=Class from 2.6 kW up to 3.0 kW of rated power in cooling 35=Class from 3.1 kW up to 3.5 kW of rated power in cooling Position 4: Operation specification (SF=cooling only, HP=heat pump) Position 5: Refrigerant (P=R290, E=R32, R=R410A) Position 6: Compressor technology (F=on/off, V=inverter) Position 7: Country specific legislation (A=Europe) Position 8: Connectivity (N=Integrated Wifi) Air conditioner with inverter motor that optimises consumption Air conditioner with 100% reclaimed refrigerant R410A Air conditioner with low-GWP R32 gas Air conditioner with R290 natural gas HRV UNICO MONO AND MULTISPLIT PORTABLES 127 Air conditioners and heat pumps without an outdoor unit UNICO TOWER Vertical format INVERTER VERSION <2.0 kW 2.1÷2.5 kW Unico Tower 25 HP RVA (02153)* UNICO TWIN For two rooms UNICO EASY Console format UNICO R 2 kW auxiliary backup ON/OFF VERSION ON/OFF VERSION ON/OFF VERSION Unico Easy S1 SF (02037) Unico Easy S1 HP (02036) Unico R 10 HP (01495) Energy efficiency class in cooling, external ambient temperature DB 35°C / WB 24°C; internal ambient temperature 27°C / WB 19°C. Unlike all other models in the range (which can be installed at the top or bottom of the wall), Unico Tower and Unico Easy can only be installed on the floor. 128 BMS HEAT PUMPS FAN COIL UNITS 2.6÷3.0 kW 3.1÷3.5 kW Unico Twin Master 30 HP RFA (02138)* Unico Twin Wall S1 (01996) Unico R 12 HP (01496) 5 6 7 8 New nomenclature Valid for products marked with * Position 1: Unique line name Position 2: Range Name (EVO, AIR, EDGE, PRO, TOWER) Position 3: Size (20, 25, 30, 35) 20=Class up to 2.0 kW of rated power in cooling 25=Class from 2.1 kW up to 2.5 kW of rated power in cooling 30=Class from 2.6 kW up to 3.0 kW of rated power in cooling 35=Class from 3.1 kW up to 3.5 kW of rated power in cooling Position 4: Operation specification (SF=cooling only, HP=heat pump) Position 5: Refrigerant (P=R290, E=R32, R=R410A) Position 6: Compressor technology (F=on/off, V=inverter) Position 7: Country specific legislation (A=Europe) Position 8: Connectivity (N=Integrated Wifi) Air conditioner with inverter motor that optimises consumption Air conditioner with 100% reclaimed refrigerant R410A Air conditioner with low-GWP R32 gas Air conditioner with R290 natural gas HRV UNICO MONO AND MULTISPLIT PORTABLES 129 Installation guidelines The main rules to follow 1. No minimum installation area according to IEC 60335-2-40 With reference to the IEC 60335-2-40 standard, all Unico models in this catalogue can be installed freely inside any room, at any height and without limits of the walkable area. R290 (A3) gas in-depth analysis according to the IEC 60335-2-40 standard The IEC 60335-2-40 standard provides the method for calculating the minimum area in which it is possible to install air conditioners containing type A3 coolant gases. Fixed air conditioners containing R290 charges greater than 152 g require verification of the walkable area of the installation room: · the higher the quantity of refrigerant charge, the larger the room must be; · the lower the installation height of the machine, the larger the room must be. The table below shows the minimum walkable areas of the rooms in which the machines can be installed, depending on the installation height and the grams of refrigerant charge (between 152 g and 988 g). Areas smaller than those indicated do not allow the installation of the air conditioner in the room in question, unless the additional precautions required by the IEC 60335-2-40 standard are adopted (such as gas sensors, additional ventilation, etc.). Minimum walkable areas of the R290 gas room Installation height of the air conditioner 0,6m 1,0m 1,8m 2,2m 152 g (Unico with R290) Free Free Free Free 153 g 37 m2 13 m2 4 m2 3 m2 Air conditioner gas charge 220 g 76 m2 28 m2 8 m2 6 m2 290 g 133 m2 48 m2 15 m2 10 m2 N.B. case-by-case checks must be carried out by the installer responsible for installing the air conditioner. The Unico air conditioners with R290 gas in this catalogue have charges lower than 152 g: it is therefore not necessary to carry out any check of the minimum installation area and they can be installed inside any room, at any height and without limits of walkable area. 130 Catalogue 2024 | January edition BMS HEAT PUMPS 2. Along the perimeter, top or bottom Unico can be installed along the entire perimeter wall of the house, near the floor or ceiling, in the centre of the wall or in the corners of the room (with the exception of the Unico Tower and Unico Easy models, which can only be installed on the floor). Check the clearance distances and installation methods in the specific manual for each model. 3. On the outside, only 2 holes The operation of Unico requires the drilling of two holes in the wall (160 or 200 mm), positioned as indicated in the drilling template, which can be downloaded in the download area of the website www.olimpiasplendid.com. In models with heat pump (HP versions) it is always necessary to make a third small hole, for the condensation drain. The Unico models, previously installed, can be easily replaced, thanks to maintaining of the same centre distance of the air inlet and outlet holes. Use the drilling templates to perform the necessary checks in preparation for installation. FAN COIL UNITS HRV UNICO MONO AND MULTISPLIT 4. Condensation drain: when needed For all HP versions it is mandatory to create a condensation drain (except in the case in which "ONLY COOLING" operation is set during installation, an option valid only for the Unico Evo PVAN and Unico Pro EVAN models). All "ONLY COOLING" versions can avoid condensation draining, provided the conditions reported in the installation manuals of the specific model are respected (first and foremost that the external air temperature must be higher than +23°C in the cooling phase). 5. Flap adjusted for better comfort Depending on the type of installation chosen, it is necessary to optimise the distribution of comfort in the room by correctly configuring the control electronics of the air outlet flap (see instructions in the manual under "High/low installation configuration"). Catalogue 2024 | January edition 131 PORTABLES NEW UNICO EVO Italian design by: The quietest and most efficient, with inverter motor and R290 gas INTEGRATED WiFi SILENT MODE With the Silent Mode function active (compressor on), it reaches a maximum of 30 dB(A). SYNC POWER SYSTEM The new Twin Rotary compressor and the latest generation electronics are synchronised to obtain the best acoustic comfort, in all operating conditions. HIGH EFFICIENCY Thanks to the new compressor and to optimising all the components, Unico Evo reaches energy class A+, in cooling mode. CONDENSATION DRAIN Mandatory (except when "ONLY COOLING" mode is set during installation). FEATURES FUNCTIONS · Two max power models: 2.3 kW and 2.5 kW · Available in the HP version (heat pump). In the absence of the condensation drain, during installation the machine can be configured in the version "ONLY COOLING", deactivating the heating function. If necessary, it is also possible to configure the machine in "ONLY HEATING" disabling the cooling function. · Cooling class: up to · Natural refrigerant gas: R290 (GWP=3) · Internal layout of the machine optimised for easy maintenance. · Large flap for homogeneous diffusion of air in the environment · Equipped with multi-filtration system, consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against bad smells). · Backlit display with touch controls on the machine. · On /off contact for enabling or energy boost. · There is an RS485 port designed to control the air conditioner with external BMS in Modbus RTU language. · 100% recyclable packaging, 98% plastic free. · Cooling, heating, dehumidification and ventilation · Economy function: allows energy savings, automatically optimising machine performance · Auto function: modulates the operating parameters in relation to the room temperature. · Silent Mode function: mode that sets the machine to the lowest noise level. The compressor and fans are set to bring the sound pressure to just 30 dB(A). · 24h timer DIMENSIONS AND WEIGHT A mm B mm C mm Weight kg 20/25 1015 180 540 41 132 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Cooling power (min/max) Heating power (min/max) Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Energy consumption for double pipe appliances (1) - cooling function Energy consumption for double pipe appliances (1) - heating function Cooling power with Silent Mode function Heating power with Silent Mode function Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode (1) Absorption in cooling mode (min/max) Absorbed power in heating mode (min/max) Maximum absorption in heating mode (min/max) Maximum power consumption with electric resistance heating Maximum absorption with electric resistance heating Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) Air flow rate with electric resistance heating environment External air flow rate in cooling (max/min) External air flow rate in heating (max/min) Internal ventilation speed External ventilation speed Diameter wall holes** Electric resistance heating Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Internal sound pressure (min/max) (2) Silent Mode sound pressure level Degree of protection provided by covers Refrigerant gas* Refrigerant gas charge Global warming potential Maximum operating pressure Power cable (N° pole x section mm²) Unico Evo 20 HP PVAN Unico Evo 25 HP PVAN 02453 02455 kW kW Prated kW Prated kW PEER kW A PCOP kW A EERd COPd 8021183024531 1,0 / 2,3 1,0 / 2,2 1,7 1,5 0,5 4,7 0,4 3,4 3,1 3,4 8021183024555 1,0 / 2,5 1,0 / 2,3 2,1 1,7 0,8 4,7 0,5 3,4 2,6 3,1 PTO W 14 14 PSB W 0,5 0,5 QDD kWh/h 0,5 0,8 QDD kWh/h 0,4 0,5 kW 1,4 1,4 kW 1,4 1,4 V-F-Hz 230-1-50 230-1-50 V 198 / 264 198 / 264 kW 0,3 / 1,0 0,3 / 1,1 A 2,5 / 7,0 2,5 / 7,2 kW 0,3 / 1,0 0,3 / 1,0 A 2,1 /5,7 2,1 /5,9 kW - - A - - l/h 0,7 0,7 m³/h 380/270/195 380/270/195 m³/h 380/270/195 380/270/195 m³/h - - m³/h 650/350 650/350 m³/h 650/350 650/350 3 3 6 6 mm 162/202 162/202 - - m / ° 8 / ±80° 8 / ±80° mm 1015 x 540 x 180 1015 x 540 x 180 mm 1100 x 605 x 290 1100 x 605 x 290 kg 41 41 kg 43 43 dB(A) 26-40 26-40 dB(A) 30 30 IP20 IP20 Type R290 R290 kg 0,145 0,145 GWP 3 3 MPa 3,1 3,1 3 x 1,5 3 x 1,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 35°C - WB 24°C DB 18°C DB 27°C - DB 43°C - WB 32°C - DB 24°C - WB 18°C DB -15°C (1) Test conditions: the data refer to the EN14511 standard - HEATING MODE: Temperature: outdoor environment DB 7°C / WB 6°C; indoor ambient DB 20°C / WB 15°C - COOLING MODE: Temperature: outdoor environment DB 35°C / WB 24°C; indoor ambient DB 27°C / WB 19°C (2) Declaration of test data in a semi-anechoic chamber at a distance of 2m, minimum pressure in ventilation only. *Hermetically sealed equipment containing natural GAS with GWP equivalent to 3. ** Machine supplied with 202 mm wall opening grilles. If necessary, to replace an old Unico, the machine can also be installed with holes of 162 mm in diameter. Catalogue 2024 | January edition 133 PORTABLES UNICO AIR The thinnest (only 16 cm thick) Italian design by: SLIM DESIGN All Unico's technology in just 16 cm thickness. Unico Air is the thinnest air conditioner without outdoor unit, SILENT SYSTEM Thanks to sound-absorbing and anti-vibration materials, sound pressure drops up to 27 dB (A)* PURE SYSTEM Equipped with a multi-filtering system, consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against unpleasant odours). CONDENSATION DRAIN Mandatory for the HP version. FEATURES FUNCTIONS · Power: 1.8 kW · Available in the versions: SF (Only cooling) - HP (Heat Pump) · Cooling class · R410A refrigerant gas · Large flap for the homogeneous diffusion of air in the environment · Equipped with a multi-filtering system, consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against unpleasant odours). · Multifunction remote control · Cooling, heating (HP only), dehumidification and ventilation · Auto function: modulates the operating parameters in relation to the room temperature. · Sleep function: gradually increases the set temperature and ensures reduced noise for better night-time well-being. · Condensation drain function: automatic draining in cooling mode. · 24 H timer DIMENSIONS AND WEIGHT A mm B mm C mm Weight kg * Measurement in a semi-anechoic chamber at 2m distance ventilation only. 134 8 978 164 491 37 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Cooling power (min/max) Heating power (min/max) Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Energy consumption for double pipe appliances (1) - cooling function Energy consumption for double pipe appliances (1) - heating function Supply voltage Supply voltage (min/max) Absorbed power in cooling mode (min/max) Absorption in cooling mode (min/max) Absorbed power in heating mode (min/max) Maximum absorption in heating mode (min/max) Maximum power consumption with electric resistance heating Maximum absorption with electric resistance heating Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) Air flow rate with electric resistance heating environment External air flow rate in cooling (max/min) External air flow rate in heating (max/min) Internal ventilation speed External ventilation speed Diameter wall holes Electric resistance heating Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Internal sound pressure (min/max) (2) Degree of protection provided by covers Refrigerant gas* Global warming potential Refrigerant gas charge Maximum operating pressure Power cable (N° pole x section mm²) Prated Prated PEER PCOP EERd COPd PTO PSB QDD QDD GWP kW kW kW kW kW A kW A W W kWh/h kWh/h V-F-Hz V kW A kW A kW A l/h m³/h m³/h m³/h m³/h m³/h mm m / ° mm mm kg kg dB(A) Type kg MPa Unico Air 8 SF 01503 8021183015034 1,8 0,7 3,1 2,6 - 14,0 0,5 0,7 230-1-50 198 / 264 0,6 215/180/150 380 3 1 162 8 / ±80° 978 x 491 x 164 1060 x 595 x 250 37 41 27-38 IP 20 R410A 2088 0,47 4,20 3 x 1,5 Unico Air 8 HP 01504 8021183015041 1,8 1,7 0,7 3,1 0,5 2,5 2,6 3,1 14,0 0,5 0,7 0,5 230-1-50 198 / 264 0,6 215/180/150 215/180/150 380 380 3 1 162 8 / ±80° 978 x 491 x 164 1060 x 595 x 250 37 41 27-38 IP 20 R410A 2088 0,47 4,20 3 x 1,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 35°C - WB 24°C DB 18°C DB 27°C - DB 43°C - WB 32°C - DB 24°C - WB 18°C DB -15°C (1) Test conditions: the data refer to the EN14511 standard - HEATING MODE: Temperature: outdoor environment DB 7°C / WB 6°C; indoor environment DB 20°C / WB 15°C - COOLING MODE: outdoor ambient temperature DB 35°C / WB 24°C; indoor environment DB 27°C / WB 19°C (2): Declaration of test data in a semi-anechoic chamber at a distance of 2m, minimum pressure in ventilation only. * Hermetically sealed equipment containing fluorinated gas with GWP equivalent 2088. ** Machine supplied with 202 mm wall opening grilles. If necessary, to replace an old Unico, the machine can also be installed with holes of 162 mm in diameter. Catalogue 2024 | January edition 135 PORTABLES UNICO AIR The slimmest, with inverter motor and R32 gas Italian design by: LOW GWP GAS Use the R32 refrigerant gas: more efficient and with greenhouse effect reduced to almost 70% (compared to R410A). SLIM DESIGN All Unico's technology in just 16 cm thickness. Unico Air is the thinnest air conditioner without outdoor unit, SILENT SYSTEM Thanks to sound-absorbing and anti-vibration materials, sound pressure drops up to 27 dB (A)* CONDENSATION DRAIN Mandatory for the HP version. FEATURES FUNCTIONS · Two models of Max power: 2.1 kW and 2.4 kW · Available in the SF (Only cooling) - HP (Heat Pump) versions · Cooling class · R32 refrigerant gas · Large flap for the homogeneous diffusion of the air in the environment · Multi-filtering system consisting of an electrostatic filter (with anti- dust function) and activated carbon filter (effective against unpleasant odours). Multifunction remote control · Cooling, heating (HP only), dehumidification and ventilation · Economy function: allows energy savings, automatically optimising machine performance · Auto function: modulates the operating parameters in relation to the room temperature. · Sleep function: gradually increases the set temperature and ensures reduced noise for better night-time well-being. · 24 H timer DIMENSIONS AND WEIGHT 20 25 A mm 978 978 B mm 164 164 C mm 491 500 Weight kg 37 39 * Measurement in a semi-anechoic chamber at 2m distance ventilation only. 136 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Cooling power (min/max) Heating power (min/max) Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Energy consumption for double pipe appliances (1) - cooling function Energy consumption for double pipe appliances (1) - heating function Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode (1) Absorption in cooling mode (min/max) Absorbed power in heating mode (min/max) Maximum absorption in heating mode (min/max) Maximum power consumption with electric resistance heating Maximum absorption with electric resistance heating Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) Air flow rate with electric resistance heating environment External air flow rate in cooling (max/min) External air flow rate in heating (max/min) Internal ventilation speed External ventilation speed Diameter wall holes Electric resistance heating Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Internal sound pressure (min/max) (2) Degree of protection provided by covers Refrigerant gas* Global warming potential Refrigerant gas charge Maximum operating pressure Power cable (N° pole x section mm²) Prated Prated PEER PCOP EERd COPd PTO PSB QDD QDD GWP kW kW kW kW kW A kW A W W kWh/h kWh/h V-F-Hz V kW A kW A kW A l/h m³/h m³/h m³/h m³/h m³/h mm m / ° mm mm kg kg dB(A) Type kg MPa Unico Air 20 SF EVA 02112 8021183021127 1,5/2,1 1,7 0,7 3,1 2,6 - 24 0,5 0,7 230-1-50 198 / 264 0,5/0,9 2,4/4,1 0,6 235/180/150 380/190 3 2 162 8 / ±80° 978 x 491 x 164 1060 x 595 x 250 37 41 27-38 IP20 R32 675 0,28 4,28 3 x 1,5 Unico Air 20 HP EVA 02111 8021183021110 1,5/2,1 1,3/1,7 1,7 1,6 0,7 3,1 0,5 2,5 2,6 3,1 24 0.5 0,7 0,5 230-1-50 198 / 264 0,5/0,9 2,4/4,1 0,4/0,8 2,0/3,7 0.6 235/180/150 235/180/150 380/190 380/190 3 2 162 8 / ±80° 978 x 491 x 164 1060 x 595 x 250 37 41 27-38 IP20 R32 675 0,28 4,28 3 x 1,5 Unico Air 25 HP EVA 02095 8021183020953 1,9/2,4 1,8/2,3 2,2 2,1 0,8 4,7 0,7 3,4 2,6 3,1 33 0,5 0,8 0,7 230-1-50 198 / 264 0,7/1,1 3,7/5,3 0,5/0,8 2,5/4,6 0,8 235/180/150 190/170/150 380/190 380/190 3 2 162 8 / ±80° 978 x 500 x 164 1060 x 595 x 250 39 43 27-38 IP20 R32 675 0,37 4,28 3 x 1,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 35°C - WB 24°C DB 18°C DB 27°C - DB 43°C - WB 32°C - DB 24°C - WB 18°C DB -15°C (1) Test conditions: the data refer to the EN14511 standard - HEATING MODE: Temperature: outdoor environment DB 7°C / WB 6°C; indoor environment DB 20°C / WB 15°C - COOLING MODE: outdoor ambient temperature DB 35°C / WB 24°C; indoor environment DB 27°C / WB 19°C (2): Declaration of test data in a semi-anechoic chamber at a distance of 2m, minimum pressure in ventilation only. * Hermetically sealed equipment containing fluorinated gas with GWP equivalent 675. Catalogue 2024 | January edition 137 PORTABLES UNICO EDGE The most versatile Italian design by: ITALIAN DESIGN Designed by Ercoli + Garlandini studio, it stands out for its smooth lines, and the retro design, combined with a "strong personality" texture. PURE SYSTEM Equipped with a multi-filtering system, consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against unpleasant odours). HEAT PUMP Heat pump air conditioner. Thanks to this feature you you can replace or support traditional heating in intermediate seasons (only in HP version). CONDENSATION DRAIN Mandatory for the HP version. FEATURES FUNCTIONS · Power: 2.7 kW · Available in the versions: SF (Only Cooling) - HP (Heat Pump) · Cooling class · R410A refrigerant gas · Equipped with a multi-filtering system, consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against unpleasant odours). · Multifunction remote control · Cooling, heating (HP only), dehumidification and ventilation · Auto function: modulates the operating parameters in relation to the room temperature. · Sleep function: gradually increases the set temperature and ensures reduced noise for better night-time well-being. · Condensation drainage function: automatic drainage in cooling mode. · 24 H timer DIMENSIONS AND WEIGHT 30 A mm 902 B mm 229 C mm 516 Weight kg 40 138 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Cooling power (min/max) Heating power (min/max) Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Energy consumption for double pipe appliances (1) - cooling function Energy consumption for double pipe appliances (1) - heating function Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode (1) Absorption in cooling mode (min/max) Absorbed power in heating mode (min/max) Maximum absorption in heating mode (min/max) Maximum power consumption with electric resistance heating Maximum absorption with electric resistance heating Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) Air flow rate with electric resistance heating environment External air flow rate in cooling (max/min) External air flow rate in heating (max/min) Internal ventilation speed External ventilation speed Diameter wall holes** Electric resistance heating Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Internal sound pressure (min/max) (2) Degree of protection provided by covers Refrigerant gas* Global warming potential Refrigerant gas charge Maximum operating pressure Power cable (N° pole x section mm²) Prated Prated PEER PCOP EERd COPd PTO PSB QDD QDD GWP kW kW kW kW kW A kW A W W kWh/h kWh/h V-F-Hz V kW A kW A kW A l/h m³/h m³/h m³/h m³/h m³/h mm m / ° mm mm kg kg dB(A) Type kg MPa Unico Edge 30 SF RFA 02132 8021183021325 2,7 1,0 4,3 2,6 - 14,0 0,5 1,0 230-1-50 198 / 264 0,9 490 / 430 / 360 520 / 350 3 3 162/202 8 / ±80° 902 x 516 x 229 980 x 610 x 350 40 44 33-42 IP20 R410A 2088 0,54 3,6 3 x 1,5 Unico Edge 30 HP RFA 02133 8021183021332 2,7 2,5 1,0 4,3 0,8 3,3 2,6 3,1 14,0 0,5 1,0 0,8 230-1-50 198 / 264 1,1 490 / 430 / 360 450 / 400 / 330 500 / 340 500 / 340 3 3 162/202 8 / ±80° 902 x 516 x 229 980 x 610 x 350 40 44 33-42 IP 20 R410A 2088 0,55 3,6 3 x 1,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 35°C - WB 24°C DB 18°C DB 27°C - DB 43°C - WB 32°C - DB 24°C - WB 18°C DB -15°C (1) Test conditions: the data refer to the EN14511 standard - HEATING MODE: Temperature: outdoor environment DB 7°C / WB 6°C; indoor environment DB 20°C / WB 15°C - COOLING MODE: outdoor ambient temperature DB 35°C / WB 24°C; indoor environment DB 27°C / WB 19°C (2): Declaration of test data in a semi-anechoic chamber at a distance of 2m, minimum pressure in ventilation only. * Hermetically sealed equipment containing fluorinated gas with GWP equivalent 2088. ** Machine supplied with 202 mm wall opening grilles. If necessary, to replace an old Unico, the machine can also be installed with holes of 162 mm in diameter. Catalogue 2024 | January edition 139 PORTABLES UNICO EDGE The most versatile, with inverter motor and R32 gas Italian design by: AWARD WINNING DESIGN Designed by Ercoli + Garlandini studio, it stands out for its smooth lines, and the retro design, combined with a "strong personality" texture. PURE SYSTEM Equipped with a multi-filtering system, consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against unpleasant odours). HEAT PUMP Heat pump air conditioner. Thanks to this feature you you can replace or support traditional heating in intermediate seasons (only in HP version). CONDENSATION DRAIN Mandatory for the HP version. FEATURES FUNCTIONS · Max Power: 3.0 kW · Available in the versions: SF (Only cooling) - HP (Heat Pump) · Cooling class · R32 refrigerant gas · Large flap for the homogeneous diffusion of the air in the environment · Multi-filtering system consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against unpleasant odours). Multifunction remote control · Cooling, heating (HP only), dehumidification and ventilation · Economy function: allows energy savings, automatically optimising machine performance · Auto function: modulates the operating parameters in relation to the room temperature. · Sleep function: gradually increases the set temperature and ensures reduced noise for better night-time well-being. · 24 H timer DIMENSIONS AND WEIGHT 30 A mm 902 B mm 229 C mm 506 Weight kg 39/40 140 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Cooling power (min/max) Heating power (min/max) Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Energy consumption for double pipe appliances (1) - cooling function Energy consumption for double pipe appliances (1) - heating function Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode (1) Absorption in cooling mode (min/max) Absorbed power in heating mode (min/max) Maximum absorption in heating mode (min/max) Maximum power consumption with electric resistance heating Maximum absorption with electric resistance heating Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) Air flow rate with electric resistance heating environment External air flow rate in cooling (max/min) External air flow rate in heating (max/min) Internal ventilation speed External ventilation speed Diameter wall holes** Electric resistance heating Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Internal sound pressure (min/max) (2) Degree of protection provided by covers Refrigerant gas* Global warming potential Refrigerant gas charge Maximum operating pressure Power cable (N° pole x section m2) Prated Prated PEER PCOP EERd COPd PTO PSB QDD QDD GWP kW kW KW kW kW A kW A W W kWh/h kWh/h V-F-Hz V kW A kW A kW A l/h m³/h m³/h m³/h m³/h m³/h mm m / ° mm mm kg kg dB(A) Type kg MPa Unico Edge 30 SF EVA 02116 8021183021165 1,9/3,0 2,7 1,0 5,0 2,6 - 29 0,5 1,0 230-1-50 198 / 264 0,7/1,4 3,4/6,6 1,1 490 / 430 / 360 520 / 350 3 6 162/202 8 / ±80° 902 x 506 x 229 980 x 610 x 350 39 43 33-43 IP 20 R32 675 0,42 4,28 3 x 1,5 Unico Edge 30 HP EVA 02115 8021183021158 1,9/3,0 1,9/3,1 2,7 2,4 1,0 5,0 0,8 3,8 2,6 3,1 29 0,5 1,0 0,8 230-1-50 198 / 264 0,7/1,4 3,4/6,6 0,6/1,1 3,1/5,8 1,1 490 / 430 / 360 490 / 430 / 360 500 / 340 500 / 340 3 6 162/202 8 / ±80° 902 x 506 x 229 980 x 610 x 350 40 43 33-43 IP 20 R32 675 0,42 4,28 3 x 1,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 35°C - WB 24°C DB 18°C DB 27°C - DB 43°C - WB 32°C - DB 24°C - WB 18°C DB -15°C (1) Test conditions: the data refer to the EN14511 standard - HEATING MODE: Temperature: outdoor environment DB 7°C / WB 6°C; indoor environment DB 20°C / WB 15°C - COOLING MODE: outdoor ambient temperature DB 35°C / WB 24°C; indoor environment DB 27°C / WB 19°C (2): Declaration of test data in a semi-anechoic chamber at a distance of 2m, minimum pressure in ventilation only. * Hermetically sealed equipment containing fluorinated gas with GWP equivalent 675. ** Machine supplied with 202 mm wall opening grilles. If necessary, to replace an old Unico, the machine can also be installed with holes of 162 mm in diameter. Catalogue 2024 | January edition 141 PORTABLES NEW UNICO PRO The most powerful, with inverter motor and R32 gas Italian design by: INTEGRATED WiFi PRO POWER Super cooling power (up to 3.5 kW) to meet the needs of even the largest environments. HIGH PERFORMANCE High efficiency class (up to A+) and state-of-the-art electronics, synchronized with the compressor to achieve the best acoustic comfort, at any operating condition. AWARD WINNING DESIGN Designed by Matteo Thun and Antonio Rodriguez, it stands out for its essential and original lines, awarded by numerous international competitions. CONDENSATION DRAIN Mandatory (except when "ONLY COOLING" mode is set during installation). FEATURES FUNCTIONS · Two models of Max power: 3.4 kW and 3.5 kW · Available in the version: HP (Heat Pump). In the absence of condensation drainage, it is possible to configure the machine, during installation, in the "ONLY COOLING" version, disabling the heating function. · Class in cooling: up to · R32 refrigerant gas · The internal components are all accessible from the front with the machine already installed · Large flap for the homogeneous diffusion of air in the environment · Equipped with a multi-filtering system, consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against unpleasant odours). · Backlit display with touch controls on the machine · On/off contact for enable or energy boost. · There is an RS485 port prepared for controlling the conditioner with external BMS in Modbus RTU language. · Cooling, heating, dehumidification and ventilation · Economy function: allows energy savings, automatically optimising machine performance · Auto function: modulates the operating parameters in relation to the room temperature. · Silent Mode function: mode that sets the machine to the lowest noise level. The compressor and fans are set to reduce the sound pressure down to only 34 dB(A). · 24 H timer DIMENSIONS AND WEIGHT A mm B mm C mm Weight kg 30/35 903 215 520 39 142 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Cooling power (min/max) Heating power (min/max) Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Energy consumption for double pipe appliances (1) - cooling function Energy consumption for double pipe appliances (1) - heating function Cooling power with Silent Mode function Heating power with Silent Mode function Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode (1) Absorption in cooling mode (min/max) Absorbed power in heating mode (min/max) Maximum absorption in heating mode (min/max) Maximum power consumption with electric resistance heating Maximum absorption with electric resistance heating Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) Air flow rate with electric resistance heating environment External air flow rate in cooling (max/min) External air flow rate in heating (max/min) Internal ventilation speed External ventilation speed Diameter wall holes** Electric resistance heating Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Internal sound pressure (min/max) (2) Silent Mode sound pressure level Degree of protection provided by covers Refrigerant gas* Refrigerant gas charge Global warming potential Maximum operating pressure Power cable (N° pole x section mm²) Unico Pro 30 HP EVAN Unico Pro 35 HP EVAN 02238 02239 kW kW Prated kW Prated kW PEER kW A PCOP kW A EERd COPd 8021183022384 1,9/3,4 1,5/3,0 2,6 1,8 0,8 4,0 0,5 3,6 3,1 3,4 8021183022391 1,9 / 3,5 1,5 / 3,2 3,1 2,4 1,2 4,3 0,8 3,76 2,6 3,1 PTO W 22 22 PSB W 0,5 0,5 QDD kWh/h 0,8 0,8 QDD kWh/h 0,5 0,7 kW 1,9 1,9 kW 1,5 1,5 V-F-Hz 230-1-50 230-1-50 V 198 / 264 198 / 264 kW 0,5/1,5 0,5 / 1,5 A 3,1/7,5 3,1 / 7,5 kW 0,4/1,4 0,4 / 1,4 A 2,5/6,8 2,5 / 6,8 kW - - A - - l/h 1,3 1,3 m³/h 490 / 390 / 350 490 / 390 / 350 m³/h 490 / 390 / 350 490 / 390 / 350 m³/h - - m³/h 600/120 600/120 m³/h 600/120 600/120 3 3 6 6 mm 162 / 202 162 / 202 - - m / ° 8 / ±80° 8 / ±80° mm 903 x 520 x 215 903 x 520 x 215 mm 980 x 610 x 330 980 x 610 x 330 kg 39 39 kg 42 42 dB(A) 32-41 32 - 43 dB(A) 34 34 IP 20 IP 20 Type R32 R32 kg 0,46 0,46 GWP 675 675 MPa 4,28 4.28 3 x 1,5 3 x 1,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 35°C - WB 24°C DB 18°C DB 27°C - DB 43°C - WB 32°C - DB 24°C - WB 18°C DB -15°C (1) Test conditions: the data refer to the EN14511 standard - HEATING MODE: Temperature: outdoor environment DB 7°C / WB 6°C; indoor environment DB 20°C / WB 15°C - COOLING MODE: outdoor ambient temperature DB 35°C / WB 24°C; indoor environment DB 27°C / WB 19°C (2): Declaration of test data in a semi-anechoic chamber at a distance of 2m, minimum pressure in ventilation only. * Hermetically sealed equipment containing fluorinated gas with GWP equivalent 675. ** Machine supplied with 202 mm wall opening grilles. If necessary, to replace an old Unico, the machine can also be installed with holes of 162 mm in diameter. Catalogue 2024 | January edition 143 PORTABLES UNICO TOWER The air conditioner without outdoor unit, in vertical format, with inverter motor SPACE SAVING Developed vertically, it brings comfort where any other installation would be impossible, such as the corner of a room or the space between two windows. INVERTER SYSTEM New generation inverter motor, with a wide frequency range and DC inverter fans. TOUCHSCREEN DISPLAY Backlit display and touch controls on the machine. CONDENSATION DRAIN Mandatory. FEATURES · Max power: 2.9 kW · Available in the version: HP (heat pump) · Cooling class: up to · Coolant gas: R410A · All-metal body · Floor-mounted installation · Backlit display with on-board touch controls · Multifunction remote control with LCD display as standard FUNCTIONS · Cooling, heating, dehumidification and ventilation · Economy function: allows energy savings, automatically optimising machine performance · Auto function: modulates the operating parameters in relation to the room temperature. · Silent Mode function: mode that sets the machine to the lowest noise level. The compressor and fans are set to reduce the sound pressure down to only 31 dB(A). · 24 H timer DIMENSIONS AND WEIGHT 25 A mm 470 B mm 185 C mm 1390 Weight kg 54 144 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Cooling power (min/max) Heating power (min/max) Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Energy consumption for double pipe appliances (1) - cooling function Energy consumption for double pipe appliances (1) - heating function Cooling power with Silent Mode function Heating power with Silent Mode function Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode (1) Absorption in cooling mode (min/max) Absorbed power in heating mode (min/max) Maximum absorption in heating mode (min/max) Maximum power consumption with electric resistance heating Maximum absorption with electric resistance heating Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) Air flow rate with electric resistance heating environment External air flow rate in cooling (max/min) External air flow rate in heating (max/min) Internal ventilation speed External ventilation speed Diameter wall holes Electric resistance heating Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Internal sound pressure (min/max) (2) Silent Mode sound pressure level Degree of protection provided by covers Refrigerant gas* Global warming potential Refrigerant gas charge Maximum operating pressure Power cable (N° pole x section mm²) kW kW Prated kW Prated kW PEER kW A PCOP kW A EERd COPd PTO W PSB W QDD kWh/h QDD kWh/h kW kW V-F-Hz V kW A kW A kW A l/h m³/h m³/h m³/h m³/h m³/h mm m / ° mm mm kg kg dB(A) dB(A) Type GWP kg MPa Unico Tower 25 HP RVA 02153 8021183021530 1,5 / 2,9 1,5 / 3,1 2,4 2,3 0,9 4,9 0,7 3,7 2,6 3,1 29 0,5 0,9 0,7 1,5 1,5 230-1-50 198 / 264 0,5/1,7 3,5/8,5 0,4/1,4 3,1/6,20 1,0 260/200/175 260/200/175 486/230 486/230 3 6 162 8 / ±80° 470 x 1390 x 185 54 27-40 31 IP20 R410A 2088 0,50 4,20 3 x 1,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 35°C - WB 24°C DB 18°C DB 27°C - DB 43°C - WB 32°C - DB 24°C - WB 18°C DB -15°C (1) Test conditions: the data refer to the EN14511 standard - HEATING MODE: Temperature: outdoor environment DB 7°C / WB 6°C; indoor environment DB 20°C / WB 15°C - COOLING MODE: outdoor ambient temperature DB 35°C / WB 24°C; indoor environment DB 27°C / WB 19°C (2): Declaration of test data in a semi-anechoic chamber at a distance of 2m, minimum pressure in ventilation only. * Hermetically sealed equipment containing fluorinated gas with GWP equivalent 2088. Catalogue 2024 | January edition 145 PORTABLES UNICO TWIN The only system to air condition two rooms without outdoor units TWIN TECHNOLOGY Twin technology allows the use of the two units (Master unit and Wall unit) simultaneously or separately depending on requirements, both in heating and cooling mode. PURE SYSTEM Equipped with a multi-filtering system, consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against unpleasant odours). HEAT PUMP Heat pump air conditioner. Thanks to this feature you you can replace or support traditional heating in intermediate seasons (only in HP version). CONDENSATION DRAIN Mandatory. SYSTEM features FUNCTIONS · Power: 2.6 kW for the master unit and 2.5 kW for the wall unit · Independent or combined operation: if simultaneous operation is chosen, the two units share the available power and are forced to the minimum available speed · Available in the version: HP (heat pump) · Cooling class: · Coolant gas: R410A · Equipped with a multi-filtration system, consisting of an electrostatic filter (with anti-dust function) and an activated carbon filter (effective against odours). · Dual multi-function remote control · Cooling, heating , dehumidification and ventilation · Auto function: modulates the operating parameters in relation to the room temperature. · Sleep function: gradually increases the set temperature and ensures reduced noise for better night-time well-being. · 24 H timer MASTER features · Cooling capacity: 2.6 kW · Capacity in HP (heat pump) function: 2.5 kW · Installation versatility: Top or bottom wall installation. · Ease of installation: Unico Twin is installed completely from the inside in a few minutes. · Wide flap for a homogeneous diffusion of the air into the room. WALL features · Nominal cooling capacity: 2,5 kW · Nominal heating capacity: 2,2 kW · Sound power level: from 25 to 36 dB(A) DIMENSIONS AND WEIGHT A mm B mm C mm Weight kg UNICO TWIN MASTER 902 229 516 40.5 146 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV TECHNICAL DATA PRODUCT CODE EAN CODE Nominal cooling capacity (1) Prated Nominal heating capacity (1) Prated Nominal power consumption for cooling (1) PEER Nominal absorption for cooling (1) Nominal power consumption for heating (1) PCOP Nominal absorption for heating (1) Nominal energy efficiency index (1) EERd Nominal efficiency coefficient (1) COPd Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode PTO Energy consumption in "standby" mode (EN 62301) PSB Energy consumption for double pipe appliances (1) - cooling function QDD Energy consumption for double pipe appliances (1) - heating function QDD Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode Maximum absorption in cooling mode Maximum power consumption in heating mode Maximum absorption in heating mode Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) Air flow rate in cooling environment (max/med/min) External air flow rate in heating (max/min) Internal ventilation speed External ventilation speed Diameter wall holes** Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Internal sound pressure (min/max) (2) Degree of protection provided by covers Refrigerant gas* Global warming potential GWP Refrigerant gas charge Power cable (N° pole x section mm²) kW kW kW A kW A W W kWh/h kWh/h V-F-Hz V W A W A l/h m³/h m³/h m³/h m³/h mm mm mm kg kg dB(A) Type kg Unico Twin Master 30 HP RFA 02138 8021183021387 2,6 2,5 0,9 4,3 0,8 3,5 2,7 3,1 14,0 0,5 0,9 0,8 230-1-50 198 / 264 1200 5,4 1080 4,8 1,1 490 / 430 / 360 450 / 400 / 330 500 / 370 / 340 500 / 370 / 340 3 3 162/202 902 x 516 x 229 980 x 610 x 350 40,5 44,0 33-42 IP 20 R410A 2088 0,78 3 x 1,5 TECHNICAL DATA Unico Twin Wall S1 PRODUCT CODE 01996 EAN CODE 8021183019964 Nominal cooling capacity (1) kW 2,5 Nominal heating capacity (1) kW 2,2 Nominal power consumption for cooling (1) kW 0,9 Nominal absorption for cooling (1) A 4,2 Nominal power consumption for heating (1) kW 0,7 Nominal absorption for heating (1) A 3,2 Maximum power consumption in cooling mode W 1200 Maximum absorption in cooling mode A 5,4 Maximum power consumption in heating mode W 1080 Maximum absorption in heating mode A 4,8 Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) Internal ventilation speed l/h 1,0 m³/h 310 / 230 / 180 m³/h 470 / 360 / 310 3 Dimensions (WxHxD) (without packaging) mm 805 x 285 x 194 Dimensions (WxHxD) (with packaging) mm 870 x 360 x 270 Weight (without packaging) kg 7,5 Weight (with packaging) kg 9,6 Internal sound pressure (2) dB(A) 25-36 Degree of protection provided by covers IP X1 Power cable (N° pole x section mm²) 3 x 1 Connecting liquid pipeline diameter inch - mm 1/4 - 6,35 Connecting gas pipeline diameter inch - mm 3/8 - 9,52 Maximum piping length m 10 Maximum height difference m 5 Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 35°C - WB 24°C DB 18°C DB 27°C - DB 43°C - WB 32°C - DB 24°C - WB 18°C DB -10°C Performance and optimal operation are guaranteed with units operating alternately. * Equipment not hermetically sealed containing fluorinated gases with an equivalent GWP of 2088. Performance is measured with 5 m gas pipes. (1) Test conditions: the data refer to the EN14511 standard - HEATING MODE: Temperature: outdoor environment DB 7°C / WB 6°C; indoor environment DB 20°C / WB 15°C - COOLING MODE: outdoor ambient temperature DB 35°C / WB 24°C; indoor environment DB 27°C / WB 19°C (2): Declaration of test data in a semi-anechoic chamber at a distance of 2m, minimum pressure in ventilation only. * Equipment not hermetically sealed containing fluorinated gases with an equivalent GWP of 2088. ** Machine supplied with 202 mm wall opening grilles. If necessary, to replace an old Unico, the machine can also be installed with holes of 162 mm in diameter. Ease of installation MASTER UNIT Thanks to the practical template with two 202 mm holes included in the packaging, in minutes you can install, completely from the inside, the MASTER unit in the first room to be climate-controlled. The MASTER unit is connected to the WALL unit, thanks to the refrigeration taps housed on the right-hand side of the unit. Maximum length of refrigerant lines of 10 metres. It is not possible to add gas beyond the pre-charge. WALL UNIT The WALL unit is installed on the wall, in the second room to be climate-controlled. UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 147 UNICO EASY The consolle air-conditioner without outdoor unit. SUPPORTING LEGS Equipped with two supporting legs for a more stable positioning. TOUCHSCREEN DISPLAY Latest generation digital control panel, for precise control over all the functions. HEAT PUMP Heat pump air conditioner. Thanks to this feature you you can replace or support traditional heating in intermediate seasons (only in HP version). CONDENSATION DRAIN Mandatory for the HP version. FEATURES · Max Power: 2.0 kW · Available in the versions: SF (Only Cooling) - HP (Heat Pump) · Cooling class · R410A refrigerant gas · Floor installation · Control display on the touch screen machine · Remote control FUNCTIONS · Cooling, heating (HP only), dehumidification and ventilation · Auto function: modulates the operating parameters in relation to the room temperature. · Sleep function: gradually increases the set temperature and ensures reduced noise for better night-time well-being. · 24 H timer DIMENSIONS AND WEIGHT A mm B mm C mm Weight kg UNICO EASY 693 276 665 36 148 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Cooling power (min/max) Heating power (min/max) Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Energy consumption for double pipe appliances (1) - cooling function Energy consumption for double pipe appliances (1) - heating function Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode Maximum absorption in cooling mode Maximum power consumption in heating mode Maximum absorption in heating mode Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) External air flow rate in cooling (max/min) External air flow rate in heating (max/min) Internal ventilation speed External ventilation speed Diameter wall holes** Electric resistance heating Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Internal sound power level (EN 12102) Degree of protection provided by covers Refrigerant gas* Global warming potential Refrigerant gas charge Maximum operating pressure Power cable (N° pole x section mm²) kW kW Prated kW Prated kW PEER kW A PCOP kW A EERd COPd PTO W PSB W QDD kWh/h QDD kWh/h V-F-Hz V kW A kW A l/h m³/h m³/h m³/h m³/h mm m / ° mm mm kg kg LWA dB(A) Type GWP kg MPa Unico Easy S1 SF 02037 8021183020373 2,0 0,8 3,45 2,6 - 1,0 0,5 0,8 220/240-1-50 198 / 264 1,027 5,46 2,2 405 / 370 / 335 505 / 0 3 2 162 8 / ±80° 693 x 665 x 276 770 x 865 x 421 36 41 60 IP X0 R410A 2088 0,51 4,2 3 x 1,5 Unico Easy S1 HP 02036 8021183020366 2,0 1,8 0,8 3,45 0,7 3,00 2,6 2,7 1,0 0,5 0,8 0,7 220/240-1-50 198 / 264 1,036 5,55 1,036 5,6 2,2 405 / 370 / 335 405 / 370 / 335 505 / 0 505 / 0 3 2 162 8 / ±80° 693 x 665 x 276 770 x 865 x 423 35,6 40,9 60 IPX0 R410A 2088 0,515 4,2 3 x 1,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 32°C WB 24°C DB 18°C DB 27°C - DB 43°C - WB 32°C - DB 24°C - WB 18°C DB -5°C (1) Test conditions: the data refer to the EN14511 standard - HEATING MODE: Temperature: outdoor environment DB 7°C / WB 6°C; indoor environment DB 20°C / WB 15°C - COOLING MODE: outdoor ambient temperature DB 35°C / WB 24°C; indoor environment DB 27°C / WB 19°C * Hermetically sealed equipment containing fluorinated gas with GWP equivalent 2088. Catalogue 2024 | January edition 149 PORTABLES UNICO R With auxiliary backup, for the harshest climates RECLAIMED REFRIGERANT It uses R410A reclaimed refrigerant gas. This refrigerant, identical to virgin refrigerant in purity and specifications, is reclaimed from existing industrial processes and subsequently re-processed. By avoiding the production of virgin refrigerant, Unico contributes to the development of a circular economy. +2 KW AUXILIARY BACKUP Unico R is designed for the coldest temperatures. When the outdoor ambient temperatures are below 2°C, the heating mode is obtained by activating the electric heating elements and the fan only. For temperatures above 2°C, heating is obtained by means of a heat pump. The management of one or the other mode is completely automatic. HEAT PUMP Heat pump air conditioner. Thanks to this feature you you can replace or support traditional heating in intermediate seasons. CONDENSATION DRAIN Mandatory. FEATURES FUNCTIONS · Two power models: 2.3 kW - 2.7 kW · Available in the versions: HP (Heat Pump) · Cooling class · Reclaimed R410A refrigerant gas · Bottom installation recommended, for enhanced air distribution · Equipped with a multi-filtering system, consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against unpleasant odours). · Multifunction remote control · Cooling, heating , dehumidification and ventilation · Auto function: modulates the operating parameters in relation to the room temperature. · Sleep function: gradually increases the set temperature and ensures reduced noise for better night-time well-being. · 24 H timer DIMENSIONS AND WEIGHT A mm B mm C mm Weight kg 10/12 902 229 516 40 150 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Cooling power (min/max) Heating power (min/max) Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Energy consumption for double pipe appliances (1) - cooling function Energy consumption for double pipe appliances (1) - heating function Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode Maximum absorption in cooling mode Maximum power consumption in heating mode Maximum absorption in heating mode Maximum power consumption with electric resistance heating Maximum absorption with electric resistance heating Dehumidification capacity Air flow rate in cooling environment (max/med/min) Air flow rate in heating environment (max/med/min) Air flow rate with electric resistance heating environment External air flow rate in cooling (max/min) External air flow rate in heating (max/min) Internal ventilation speed External ventilation speed Diameter wall holes** Electric resistance heating Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Internal sound pressure (min/max) (2) Degree of protection provided by covers Refrigerant gas* Global warming potential Refrigerant gas charge Maximum operating pressure Power cable (N° pole x section mm²) kW kW Prated kW Prated kW PEER kW A PCOP kW A EERd COPd Unico R 10 HP 01495 8021183014952 2,3 2,3 0,9 3,70 0,7 3,0 2,6 3,1 Unico R 12 HP 01496 8021183014969 2,7 2,5 1,0 4,30 0,8 3,3 2,6 3,1 PTO W 14,0 14,0 PSB W 0,5 0,5 QDD kWh/h 0,9 1,0 QDD kWh/h 0,7 0,8 V-F-Hz 230-1-50 230-1-50 V 198 / 264 198 / 264 kW 0,9 1,1 A 3,9 4,8 kW 0,9 1,1 A 3,8 4,7 kW 2,0 2,0 A 8,7 8,7 l/h 0,9 1,1 m³/h 490 / 430 / 360 490 / 430 / 360 m³/h 410 / 350 / 270 490 / 400 / 330 m³/h 490 490 m³/h 520 / 350 500 / 340 m³/h 520 / 350 500 / 340 3 3 3 3 mm 162/202 162/202 W 2000 2000 m / ° 8 / ±80° 8 / ±80° mm 902 x 516 x 229 902 x 516 x 229 mm 980 x 610 x 350 980 x 610 x 350 kg 40 40 kg 44 44 dB(A) 33-41 33-42 IP 20 IP 20 Type R410A reclaimed R410A reclaimed GWP 2088 2088 kg 0,65 0,55 MPa 3,6 3,6 3 x 1,5 3 x 1,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 35°C - WB 24°C DB 18°C DB 27°C - DB 43°C - WB 32°C - DB 24°C - WB 18°C DB -15°C (1) Test conditions: the data refer to the EN14511 standard - HEATING MODE: Temperature: outdoor environment DB 7°C / WB 6°C; indoor environment DB 20°C / WB 15°C - COOLING MODE: outdoor ambient temperature DB 35°C / WB 24°C; indoor environment DB 27°C / WB 19°C (2): Declaration of test data in a semi-anechoic chamber at a distance of 2m, minimum pressure in ventilation only. * Hermetically sealed equipment containing fluorinated gas with GWP equivalent 2088. ** Unico R is supplied with 202 mm wall opening grilles. If necessary, to replace an old Unico, the machine can also be installed with holes of 162 mm in diameter. Catalogue 2024 | January edition 151 PORTABLES Accessories B1015 Kit Wi-Fi Unico Wi-Fi/Bluetooth interface card. Compatible with: UNICO AIR UNICO EDGE UNICO PRO (EVAN escluso) UNICO TOWER UNICO R B1014 Wireless serial interface Interface for receiving wireless commands (desired temperature, ventilation speed, air deflector operation and air change function) or via contacts (Cooling or Heating operating mode, ventilation speed). Presence sensor contact or Sleep mode. Alarm output in case of malfunction. Compatible with: UNICO AIR UNICO EDGE UNICO PRO (EVAN escluso) UNICO TOWER UNICO EASY UNICO R B1012 Wireless Wall Control Battery-powered wall-mounted control for sending wireless commands (desired temperature, ventilation speed, air deflector operation). Compatible with: UNICO AIR UNICO EDGE UNICO PRO (EVAN escluso) UNICO TOWER UNICO EASY UNICO R B0776 Closing panel for recessed structure Designed to completely camouflage the product within the architecture of the building. Compatible with: UNICO AIR B0775 Recessed formwork kit Supplied for quick installation and already prepared with holes for installation of the product. Compatible with: UNICO AIR B0565 B0984 NEW 200mm diameter installation kit 1:1 scale installation template (valid for Unico Edge and Unico R), support bracket, PP universal sheets, pair of indoor flanges Ø 200 mm, pair of outdoor folding grilles Ø 200 mm. Compatible with: UNICO EDGE UNICO TWIN UNICO R Kit for preparing holes with a diameter of 200 mm Kit for preparing holes with a diameter of 200 mm equipped with a pair of 200mm folding grids, a pair of 200mm internal flanges, a pair of universal PP sheets, templates for each compatible model (there are no support brackets, which are included in the machine packaging). Compatible with: UNICO EVO UNICO EDGE UNICO PRO UNICO TWIN UNICO R B0564 Grille kit diameter 160 mm Pair of inside flanges Ø 160 mm, pair of outside folding grilles Ø 160 mm. Compatible with: UNICO EVO UNICO AIR UNICO EDGE UNICO PRO UNICO TOWER UNICO TWIN UNICO EASY UNICO R B0620 Heating cable To prevent the formation of ice in the condensation trap for drainage. Compatible with: UNICO EVO UNICO AIR UNICO EDGE UNICO PRO UNICO TWIN UNICO R B0753 152 200 mm rain cover kit To be installed on the outside wall to protect the holes (for installations in extreme weather conditions). Designed for ø 200 mm grilles. This product is available by special order only. The packaging contains 2 elements (1 for each hole). Compatible with: UNICO EVO UNICO AIR UNICO EDGE UNICO PRO UNICO TWIN UNICO R UNICO EASY Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV Wi-Fi Control In-depth analysis on control from smartphones and tablets Unico air conditioners without outdoor units can be controlled easily, inside and outside the home, even from smartphones and tablets. To activate them and set the main functions, simply download the iOS or Android application compatible with your air conditioner model and, if Wi-Fi is not integrated, request the installation of the dedicated interface card (code B1015 optional). Olimpia Splendid Unico This is the app available for the Unico Air, Unico Edge, Unico Pro (EVAN excluded), Unico Tower and Unico R models, in combination with the dedicated interface card (code B1015). OS Home This is the app available for the new generation of air conditioners, with integrated Wi-Fi, Unico Evo and Unico Pro (EVAN). All applications allow you to manage one or more air conditioners without an outdoor unit installed in the house, to display the room temperature and to set the main modes (cooling, heating, dehumidification, ventilation), as well as to program the on and off timers. Discover the new management and remote control potential of the Unico Evo and Unico Pro (EVAN) versions with integrated Wi-Fi on the Olimpiasplendid.it website. 153 UNICO MONO AND MULTISPLIT PORTABLES Built-in Unico How to make the air conditioner invisible, inside and outside the home Compatible with all Unico Air models Unico Air is the slimmest air conditioner ever without outdoor unit. The reduced thickness (only 16 cm) makes it perfect for recessed installation, thus concealing the air conditioner, both inside and out. With the use of the special front panel and the formwork, it will finally be possible to completely hide the devices for home comfort. A 1173 mm RECESSED PANEL B 9 mm C 754 mm FORMWORK FOR RECESS A B C 1114 mm 171 mm 725 mm 154 155 PORTABLES MONO AND MULTISPLIT UNICO HRV FAN COIL UNITS HEAT PUMPS BMS NEXYA Monosplit and multisplit air conditioners Maximum efficiency and complete air treatment Olimpia Splendid's fixed air conditioning ranges offers a truly complete well-being High efficiency e low GWP The Olimpia Splendid air conditioners are among best performing in terms of energy efficiency (reaching up to a class of A+++) and use R32 refrigerant, which has a greenhouse effect reduced by almost 70% (compared to R410A). Technologies for Indoor Air Quality Good indoor air quality is an integral part of a comfortable, healthy and safe home, and the technological development of Olimpia Splendid is oriented at transforming air conditioners into increasingly advanced air treatment devices. This is why the internal units include cold catalyst filters, useful for inhibiting harmful gases (such as formaldehyde and benzene) and automatic high-temperature sterilisation functions. For climate comfort that is safer for everyone. 158 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV UNICO Wi-Fi kit: how to connect the air conditioner to your smartphone Easy to install and set up All the wall, duct, cassette and ceiling internal units of Olimpia Splendid's fixed air conditioners can be fitted with Wi-Fi connectivity to manage the comfort settings remotely, out of the home, via the 3G and 4G network from your smartphone. There are two solutions available: - Wi-Fi B1020 kit: consisting of a special USB key to insert independently in the dedicated port under the front panel. The kit is included with all the wall units while it is optional (to order) for all the cassette internal units, sizes 24, 36 single- and three-phase and 48 three-phase. - Wi-Fi B0970 kit: consisting of a disc, to be installed outside the wall/ceiling internal unit, containing a USB key for Wi-Fi integration. The kit is optional (to order) for duct (sizes 9, 12, 18, 24, 36, 36T, 48T), ceiling (sizes 9, 12, 18, 24, 36, 36T, 48T) and cassette (sizes 9, 12, 18) indoor units. OS Comfort is Olimpia Splendid's application to control the air conditioner from your smartphone. Available for download on the Apple Store and Google Play. App features Available for iPhone and iPad with IOS Operating System and for smartphones and tablets with Android Operating System (compatibility indication available on Apple Store and Google Play). It is used to manage one or more air conditioners. App functionality · All modes can be set: heating, cooling, dehumidification, ventilation only, automatic · Special functions can also be set: turbo, vertical and horizontal swing, echo · Room temperature display · Weekly timer with 1 time slot, with fixed modes and set points · Frost protection: automatic activation of the air conditioner with ambient temperature below 8°C · Sleep setting: possibility to manage the set point for each hour of the day MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 159 Monosplit and multisplit air conditioners NEXYA ENERGY E High wall mono-split air conditioners Outdoor units Indoor Units SINGLE-PHASE ODU 9 UE Nexya Energy E 9 (OS-CEENH09EI) UI Nexya Energy E 9 (OS-SEENH09EI) 12 UE Nexya Energy E 12 (OS-CEENH12EI) UI Nexya Energy E 12 (OS-SEENH12EI) NEXYA S4 E High wall mono-split air conditioners Outdoor units Indoor Units UE Nexya S4 E inverter 9 C (OS-KENEH09EI) UI Nexya S4 E Inverter 9 (OS-SENEH09EI) UE Nexya S4 E inverter 12 C (OS-KENEH12EI) UI Nexya S4 E Inverter 12 (OS-SENEH12EI) NEXYA COMMERCIAL DUCT Mono-split air conditioners for large rooms NEXYA COMMERCIAL CASSETTE Mono-split air conditioners for large rooms Outdoor units Indoor Units Outdoor units Indoor Units NEXYA COMMERCIAL CEILING Mono-split air conditioners for large rooms Outdoor units Indoor Units Dual 14 Dual 18 NEXYA MULTISPLIT Multisplit Outdoor units Wall internal units UE Nexya S5 E Dual inverter 14 (OS-CANMH14EI) UI Nexya S4 E inverter 9 (OS-SENEH09EI) UE Nexya S5 E Dual inverter 18 (OS-CANMH18EI) UI Nexya S4 E inverter 9 (OS-SENEH09EI) UI Nexya S4 E inverter 12 (OS-SENEH12EI) UI Nexya S4 E inverter 12 (OS-SENEH12EI) UI Nexya S4 E inverter 18 (OS-SENEH18EI) UI Nexya S4 E inverter 18 (OS-SENEH18EI) Duct internal units UI Nexya S5 E Duct 9 (OS-SANDH09EI) NEW UI Nexya S5 E Duct 9 (OS-SANDH09EI) NEW UI Nexya S5 E Duct 12 (OS-SANDH12EI) UI Nexya S5 E Duct 12 (OS-SANDH12EI) UI Nexya S5 E Duct 18 (OS-SANDH18EI) UI Nexya S5 E Duct 18 (OS-SANDH18EI) Cassette internal units UI Nexya S5 E Cassette Compact 9 (OS-K/SANCH09EI) NEW UI Nexya S5 E Cassette Compact 9 (OS-K/SANCH09EI) NEW UI Nexya S5 E Cassette Compact 12 (OS-K/SANCH12EI) UI Nexya S5 E Cassette Compact 12 (OS-K/SANCH12EI) UI Nexya S5 E Cassette Compact 18 (OS-K/SANCH18EI) UI Nexya S5 E Cassette Compact 18 (OS-K/SANCH18EI) Energy efficiency class in cooling depending on the reference operating conditions of each model. For multi-split units, the energy class listed here refers to the most efficient combination. 160 Catalogue 2024 | January edition BMS ODU THREE PHASE 18 24 36 36T 48T HEAT PUMPS FAN COIL UNITS HRV UE Nexya S4 E inverter 18 C (OS-KENEH18EI) UI Nexya S4 E Inverter 18 (OS-SENEH18EI) UE Nexya S4 E inverter 24 C NEW (OS-KENEH24EI) UI Nexya S4 E inverter 24 (OS-SENEH24EI) UE Nexya S5 E Commercial 18 (OS-CANCH18EI) UI Nexya S5 E Duct 18 (OS-SANDH18EI) UE Nexya S5 E Commercial 24 (OS-CANCH24EI) UI Nexya S5 E Duct 24 (OS-SANDH24EI) UE Nexya S5 E Commercial 36 (OS-CANCH36EI) UE Nexya S5 E Commercial 36T (OS-CANCHT36EI) UI Nexya S5 E Duct 36 (OS-SANDH36EI) UE Nexya S4 E Commercial 48T (OS-CECITH48EI) UI Nexya S5 E Duct 48 (OS-SANDH48EI) UE Nexya S5 E Commercial 18 (OS-CANCH18EI) UI Nexya S5 E Cassette Compact 18 (OS-K/SANCH18EI) UE Nexya S5 E Commercial 24 (OS-CANCH24EI) UI Nexya S5 E Cassette 24 (OS-K/SANCH24EI) UE Nexya S5 E Commercial 36 (OS-CANCH36EI) UE Nexya S5 E Commercial 36T (OS-CANCHT36EI) UI Nexya S5 E Cassette 36 (OS-K/SANCH36EI) UE Nexya S5 E Commercial 48T (OS-CANCHT48EI) UI Nexya S5 E Cassette 48 (OS-K/SANCH48EI) UE Nexya S5 E Commercial 18 (OS-CANCH18EI) UI Nexya S5 E Ceiling 18 (OS-SANFH18EI) UE Nexya S5 E Commercial 24 (OS-CANCH24EI) UI Nexya S5 E Ceiling 24 (OS-SANFH24EI) UE Nexya S5 E Commercial 36 (OS-CANCH36EI) UE Nexya S5 E Commercial 36T (OS-CANCHT36EI) UI Nexya S5 E Ceiling 36 (OS-SANFH36EI) UE Nexya S5 E Commercial 48T (OS-CANCHT48EI) UI Nexya S5 E Ceiling 48 (OS-SANFH48EI) Trial 21 UE Nexya S5 E Trial inverter 21 (OS-CANMH21EI) UI Nexya S4 E inverter 9 (OS-SENEH09EI) UI Nexya S4 E inverter 12 (OS-SENEH12EI) UI Nexya S4 E inverter 18 (OS-SENEH18EI) UI Nexya S5 E Duct 9 NEW (OS-SANDH09EI) UI Nexya S5 E Duct 12 (OS-SANDH12EI) UI Nexya S5 E Duct 18 (OS-SANDH18EI) UI Nexya S5 E Cassette Compact 9 NEW (OS-K/SANCH09EI) UI Nexya S5 E Cassette Compact 12 (OS-K/SANCH12EI) UI Nexya S5 E Cassette Compact 18 (OS-K/SANCH18EI) Quadri 28 UE Nexya S4 E Quadri inverter 28 (OS-CEMYH28EI) UI Nexya S4 E inverter 9 (OS-SENEH09EI) UI Nexya S4 E inverter 12 (OS-SENEH12EI) UI Nexya S4 E inverter 18 (OS-SENEH18EI) UI Nexya S5 E Duct 9 NEW (OS-SANDH09EI) UI Nexya S5 E Duct 12 (OS-SANDH12EI) UI Nexya S5 E Duct 18 (OS-SANDH18EI) UI Nexya S5 E Cassette Compact 9 NEW (OS-K/SANCH09EI) UI Nexya S5 E Cassette Compact 12 (OS-K/SANCH12EI) UI Nexya S5 E Cassette Compact 18 (OS-K/SANCH18EI) Penta 42 UE Nexya S5 E Penta inverter 42 (OS-CANMH42EI) UI Nexya S4 E inverter 9 (OS-SENEH09EI) UI Nexya S4 E inverter 12 (OS-SENEH12EI) UI Nexya S4 E inverter 18 (OS-SENEH18EI) UI Nexya S5 E Duct 9 NEW (OS-SANDH09EI) UI Nexya S5 E Duct 12 (OS-SANDH12EI) UI Nexya S5 E Duct 18 (OS-SANDH18EI) UI Nexya S5 E Cassette Compact 9 NEW (OS-K/SANCH09EI) UI Nexya S5 E Cassette Compact 12 (OS-K/SANCH12EI) UI Nexya S5 E Cassette Compact 18 (OS-K/SANCH18EI) Catalogue 2024 | January edition 161 UNICO MONO AND MULTISPLIT PORTABLES NEXYA ENERGY E High-wall mono-split inverter in class A+++ HIGH EFFICIENCY High-performance R32 refrigerant gas with maximum technological efficiency, up to energy class A+++. STERILISATION AT 56°C High temperature sterilisation cycles of the evaporator to prevent bacteria from forming and to improve the quality of air. IONIZER AND AIR QUALITY TECH The treated air is subjected to an ionising action and purified with anti-dust filters, activated carbon and cold catalytic filters. WI-FI KIT INCLUDED To ensure Wi-Fi connection to the air conditioner, simply install the special USB key (included in the package) and download the OS Comfort app. FEATURES FUNCTIONS · High-performance inverter technology · Coolant gas R32 · Energy efficiency class A+++ in cooling · Remote control supplied · Golden Fin treatment on the battery of the outdoor unit, to prevent the corrosive action of atmospheric agents and improve performance efficiency. · Cooling, heating, dehumidification and ventilation · Timer, Auto, Eco, Sleep, Silent and Turbo functions · Follow Me function: precise temperature detection in the point where the remote control is located. · Breeze away and Swing functions: prevents direct air jets and automatically adjusts the air flow (horizontal and vertical) · Gear function: 3 power options (50-75-100%) to optimise energy consumption. · Auto-Restart function: after a power failure, it restarts at the last function set. · Auto-Diagnosis function: in the event of a failure, the display shows the error code. 162 BMS HEAT PUMPS FAN COIL UNITS DESIGN LOAD (EN 14825) SEASONAL EFFICIENCY (EN14825) INDOOR UNIT OUTDOOR UNIT COOLING CIRCUIT ELECTRICAL CONNECTIONS PRODUCT CODE EAN CODE Output power in cooling mode (min/rated/max) Output power in heating mode (min/rated/max) Absorbed power in cooling mode (min/rated/max) Absorbed power in heating mode (min/rated/max) Current consumption in cooling mode (min/rated/max) Current consumption in heating mode (min/rated/max) EER COP Maximum power consumption in cooling mode Maximum power consumption in heating mode Energy efficiency class in cooling Energy efficiency class in heating mode - Average season Energy efficiency class in heating mode - Warmer season Energy efficiency class in heating mode - Cold season Energy consumption in cooling mode Annual energy consumption in heating mode - Average season Annual energy consumption in heating mode - Warmer season Annual energy consumption in heating mode - Cold season Dehumidification capacity Cooling Heating / Average Heating / Warmer Heating / Colder Cooling Heating / Average Heating / Warmer Heating / Colder Sound power (EN 12102) Sound pressure (max/med/min/silence) Air flow rate in cooling mode (max/med/min) Air flow rate in heating mode (max/med/min) Degree of protection Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Sound power (EN 12102) Sound pressure Air flow rate (max) Degree of protection Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Connecting liquid pipeline diameter Connecting gas pipeline diameter Maximum piping length Maximum height difference Covered piping length from pre-load Piping recommended minimum length Refrigerant increase (over 5 m of pipes) Maximum operating pressure Refrigerant gas* Global warming potential Refrigerant gas charge Supply voltage indoor unit Supply voltage outdoor unit Outdoor unit power supply connection Indoor - Outdoor unit connection Max Current Nexya Energy E 9 Nexya Energy E 12 OS-C/SEENH09EI OS-C/SEENH12EI 8021183118728 8021183118759 kW 1,03/2,64/3,23 1,38/3,52/4,31 kW 0,82/2,93/3,37 1,07/3,81/4,38 kW 0,08/0,63/1,10 0,13/1,01/1,65 kW 0,70/0,65/0,99 0,16/0,98/1,56 A 0,35/2,73/4,78 0,6/4,37/7,2 A 0,32/2,83/4,32 0,7/4,24/6,78 4,2 3,5 4,5 3,9 kW 2,20 2,20 kW 2,20 2,20 kWh/year kWh/year kWh/year Pdesignc Pdesignh Pdesignh Pdesignh SEER SCOP ( A ) SCOP ( W ) SCOP ( C ) LWA LWA Type GWP Pipes Pipes kWh/year kWh/year kWh/year kWh/year l/h kW kW kW kW dB(A) dB(A) m³/h m³/h mm kg mm kg dB(A) dB(A) m³/h mm kg mm kg inch - mm inch - mm m m m m g/m MPa Type kg V/F/Hz V/F/Hz A 107 744 630 1891 1,5 2,6 2,4 2,7 3 8,8 4,6 6 3,5 54 37/31/22/510/360/300 510/360/300 / 835x295x208 8,7 905x355x290 11,5 58 54 2150 IP24 765x555x303 26,7 887x610x337 29,1 1/4" - 6,35 3/8" - 9,52 25 10 5 3 12 4,3/1,7 R32 675 0,62 220-240 / 1 / 50 220-240 / 1 / 50 3 x 2,5 mm2 5 x 1,5 mm2 10,5 157 797 723 1984 1,5 3,5 2,6 3,1 3,3 8,5 4,6 6 3,5 55 39/33/22/520/370/310 520/370/310 / 835x295x208 8,7 905x355x290 11,3 61 54,5 2200 IP24 765x555x303 26,7 887x610x337 29,1 1/4" - 6,35 3/8" - 9,52 25 10 5 3 12 4,3/1,7 R32 675 0,62 220-240 / 1 / 50 220-240 / 1 / 50 3 x 2,5 mm2 5 x 1,5 mm2 10,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 32°C DB 16°C DB 30°C DB 0°C DB 50°C DB 24°C DB -15°C The declared data relate to the conditions provided for in EN 14511, EN 14825 and EU Delegated Regulation 626/2011. The actual power consumption of the product, in conditions of real use, may differ from what is indicated. The data are subject to change and modification without prior notice. *Non-hermetically sealed equipment containing fluorinated gas with GWP equivalent to 675. Catalogue 2024 | January edition 163 PORTABLES NEXYA S4 E High-wall mono-split inverter in class A++ HIGH EFFICIENCY High-performance R32 refrigerant gas with maximum technological efficiency, to reach the energy class A++. AIR QUALITY TECH The treated air is purified with anti-dust filters, activated carbon and cold catalytic filters to remove impurities. SELF CLEAN Automatically cleans and dries the evaporator, removing dust, mould and grease to ensure clean air in the room. WI-FI KIT INCLUDED To ensure Wi-Fi connection to the air conditioner, simply install the special USB key (included in the package) and download the OS Comfort app. FEATURES FUNCTIONS · High-performance inverter technology · Coolant gas R32 · Energy efficiency class A++ in cooling · Remote control supplied · Golden Fin treatment on the battery of the outdoor unit, to prevent the corrosive action of atmospheric agents and improve performance efficiency. · Cooling, heating, dehumidification and ventilation · Timer, Auto, Sleep, Silent and Turbo functions · Follow Me function: precise temperature detection in the point where the remote control is located. · Swing function: oscillation of the flap for better air diffusion in the environment. · Auto-Restart function: after a power failure, it restarts at the last function set. · Auto-Diagnosis function: in the event of a failure, the display shows the error code. 164 BMS HEAT PUMPS FAN COIL UNITS NEW Nexya S4 E Inverter 9 C DESIGN LOAD (EN 14825) SEASONAL EFFICIENCY (EN14825) INDOOR UNIT OUTDOOR UNIT COOLING CIRCUIT ELECTRICAL CONNECTIONS PRODUCT CODE EAN CODE Output power in cooling mode (min/rated/max) Output power in heating mode (min/rated/max) Absorbed power in cooling mode (min/rated/max) Absorbed power in heating mode (min/rated/max) Current consumption in cooling mode (min/rated/max) Current consumption in heating mode (min/rated/max) EER COP Maximum power consumption in cooling mode Maximum power consumption in heating mode Energy efficiency class in cooling Energy efficiency class in heating mode - Average season Energy efficiency class in heating mode - Warmer season Energy efficiency class in heating mode - Cold season Energy consumption in cooling mode Annual energy consumption in heating mode - Average season Annual energy consumption in heating mode - Warmer season Annual energy consumption in heating mode - Cold season Dehumidification capacity Cooling Heating / Average Heating / Warmer Heating / Colder Cooling Heating / Average Heating / Warmer Heating / Colder Sound power (EN 12102) Sound pressure (max/med/min/silence) Air flow rate in cooling mode (max/med/min) Air flow rate in heating mode (max/med/min) Degree of protection Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Sound power (EN 12102) Sound pressure Air flow rate (max) Degree of protection Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Connecting liquid pipeline diameter Connecting gas pipeline diameter Maximum piping length Maximum height difference Covered piping length from pre-load Piping recommended minimum length Refrigerant increase (over 5 m of pipes) Maximum operating pressure Refrigerant gas* Global warming potential Refrigerant gas charge Supply voltage indoor unit Supply voltage outdoor unit Outdoor unit power supply connection Indoor - Outdoor unit connection Max Current kW kW kW kW A A kW kW kWh/year kWh/year kWh/year kWh/year l/h Pdesignc kW Pdesignh kW Pdesignh kW Pdesignh kW SEER SCOP ( A ) SCOP ( W ) SCOP ( C ) LWA dB(A) dB(A) m³/h m³/h mm kg mm kg LWA dB(A) dB(A) m³/h mm kg mm kg inch - mm inch - mm m m m m g/m MPa Type GWP kg V/F/Hz V/F/Hz Pipes Pipes A OS-K/SENEH09EI 8021183117462 0,91/2,64/3,40 0,82/2,93/3,37 0,10/0,73/1,24 0,12/0,73/1,20 0,40/3,20/5,40 0,50/3,20/5,20 3,60 4,00 2,15 2,15 156 910 714 1 2,8 2,6 2,6 6,3 4,0 5,1 54 39/32/25/466/360/325 466/360/325 IPX0 805x285x194 7,6 870x365x270 9,7 62 55,5 1750 IP24 720x495x270 23,2 835x540x300 25,0 1/4" - 6,35 3/8" - 9,52 25 10 5 3 12 4,3/1,7 R32 675 0,55 220-240 / 1 / 50 220-240 / 1 / 50 3 x 2,5 mm2 5 x 1,5 mm2 10,0 Nexya S4 E Inverter 12 C OS-K/SENEH12EI 8021183117479 1,11/3,40/4,16 1,09/3,68/4,22 0,13/1,04/1,58 0,10/0,99/1,68 0,5/4,56/6,9 0,4/4,35/6,9 3,28 3,72 2,15 2,15 211 945 706 1,2 3,6 2,7 2,5 6,1 4,0 5,1 55 41/35/25/547/430/314 625/430/314 IPX0 805x285x194 7,6 870x365x270 9,8 63 56 1800 IP24 720x495x270 23,2 835x540x300 25,0 1/4" - 6,35 3/8" - 9,52 25 10 5 3 12 4,3/1,7 R32 675 0,55 220-240 / 1 / 50 220-240 / 1 / 50 3 x 2,5 mm2 5 x 1,5 mm2 10,0 Nexya S4 E Inverter 18 C OS-K/SENEH18EI 8021183118803 3,39/5,27/5,83 3,1/4,97/5,85 0,56/1,55/2,05 0,78/1,298/2 2,4/6,7/8,9 3,4/5,64/8,7 3,4 3,83 2,50 2,50 247 1435 1208 1,6 5,2 4,1 4,4 7,4 4 5,1 56 42/36/26/840/680/540 840/680/540 IPX0 957x302x213 10 1035x385x295 13,0 63 56 2100 IPX4 805x554x330 32,7 915x615x370 35,4 1/4" - 6,35 1/2" - 12,7 30 20 5 3 12 4,3/1,7 R32 675 1,08 220-240 / 1 / 50 220-240 / 1 / 50 3 x 2,5 mm2 5 x 1,5 mm2 13,0 Nexya S4 E Inverter 24 C OS-K/SENEH24EI 8021183118810 2,08/5,86/7,91 1,61/6,0/7,91 0,42/1,787/3,15 0,3/1,608/2,75 1,8/7,77/13,8 1,3/6,99/12,2 3,28 3,73 3,50 3,50 405 1818 1691 2,4 7 4,8 5,8 6,1 4 4,8 59 45/40/36/980/817/662 980/817/662 IPX0 1040x327x220 12,3 1120x405x315 15,8 67 59 3500 IPX4 890x673x342 42,9 995x740x398 45,9 3/8" - 9,52 5/8" - 15,9 50 25 5 3 24 4,3/1,7 R32 675 1,42 220-240 / 1 / 50 220-240 / 1 / 50 3 x 2,5 mm2 5 x 2,5 mm2 15,5 HRV UNICO MONO AND MULTISPLIT Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 32°C DB 17°C DB 30°C DB 0°C DB 43°C DB 30°C DB -15°C DB 32°C DB 17°C DB 30°C DB 0°C DB 43°C DB 30°C DB -15°C DB 32°C DB 17°C DB 30°C DB 0°C DB 50°C DB 30°C DB -15°C DB 32°C DB 17°C DB 30°C DB 0°C DB 50°C DB 30°C DB -15°C The declared data relate to the conditions provided for in EN 14511, EN 14825 and EU Delegated Regulation 626/2011. The actual power consumption of the product, in conditions of real use, may differ from what is indicated. The data are subject to change and modification without prior notice. *Non-hermetically sealed equipment containing fluorinated gas with GWP equivalent to 675. 165 PORTABLES NEXYA COMMERCIAL DUCT Inverter mono-split air conditioners ducted for large rooms HYDRAULIC HEAD Centralised indoor unit with static pressure available up to 160 Pa. SLIM DESIGN The range is characterised by its small dimensions (Height from 210 mm) AUTOMATIC SETTING OF THE AIR FLOW RATE The system adapts automatically according to the ducts connected to the unit. DIGITAL DISPLAY Display on the outside of the internal unit to guaranteed he best signal reception from the remote control (*Except for size 48T, which comes with the B0969 wall-mounted wire control). FEATURES FUNCTIONS Energy-efficient inverter technology with low-GWP R32 refrigerant gas. Optimum performance and high efficiency at low airflow resulting in reduced noise. Automatic air flow rate setting Innovative automatic air flow setting function, so that the system automatically adapts according to the ducting connected to the unit. Reversible air intake The air intake duct can be moved from the rear of the product (standard configuration) to the bottom, replacing it with a sheet metal panel. This makes the product suitable for all installation conditions. Fresh air inlet The internal units of the commercial line are fitted with specific air inlets to introduce fresh or outdoor air into the product. Condensation lift pump The internal units are fitted with a condensation pump. Remote ON-OFF All units in the commercial line are fitted with terminals to control the remote switching on and off of the unit via an external device. Contact alarm The units in the commercial line have a contact that allows the alarm status of the product to be synchronised with an external device. Hydrophilic Aluminium coating Suitable for installation in coastal or particularly humid areas, thanks to its excellent anti-corrosion properties. With equivalent environmental conditions, the new coating of the condensers guarantees a durability that is 7 times greater that of the traditional models. · Cooling, heating, dehumidification and ventilation · Auto, Sleep* and Turbo* functions · 24h timer: for scheduling switch on and off. · Follow Me function: precise temperature detection at the remote control location. · Gear function*: 3 power options (50-75-100%) to optimise energy consumption. · Short cut function*: to automatically return to the previous settings. · *Functions not compatible for size 48T 166 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS DESIGN LOAD (EN 14825) SEASONAL EFFICIENCY (EN14825) INDOOR UNIT OUTDOOR UNIT INDOOR UNIT CODE INDOOR UNIT EAN CODE OUTDOOR UNIT CODE OUTDOOR UNIT EAN CODE Output power in cooling mode (min/rated/max) Output power in heating mode (min/rated/max) Absorbed power in cooling mode (min/rated/max) Absorbed power in heating mode (min/rated/max) Current consumption in cooling mode (min/rated/max) Current consumption in heating mode (min/rated/max) EER COP Maximum power consumption in cooling mode Maximum power consumption in heating mode Energy efficiency class in cooling Energy efficiency class in heating mode - Average season Energy efficiency class in heating mode - Warmer season Energy efficiency class in heating mode - Cold season Energy consumption in cooling mode Annual energy consumption in heating mode - Average season Annual energy consumption in heating mode - Warmer season Annual energy consumption in heating mode - Cold season Dehumidification capacity Cooling Heating / Average Heating / Warmer Heating / Colder Cooling Heating / Average Heating / Warmer Heating / Colder Sound power (EN 12102) Sound pressure (max/med/min/silence) Air flow rate in cooling mode (max/med/min) Air flow rate in heating mode (max/med/min) Rated fan pressure Fan pressure adjustment field Degree of protection Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Sound power (EN 12102) Sound pressure Air flow rate (max) Degree of protection Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Connecting liquid pipeline diameter COOLING CIRCUIT Connecting gas pipeline diameter Maximum piping length Maximum height difference Covered piping length from pre-load Piping recommended minimum length Refrigerant increase (over 5 m of pipes) Maximum operating pressure Refrigerant gas* Global warming potential Refrigerant gas charge Supply voltage indoor unit ELECTRICAL CONNECTIONS Supply voltage outdoor unit Outdoor unit power supply connection Indoor - Outdoor unit connection Max Current Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Nexya S5 E Duct 18 Nexya S5 E Duct 24 Nexya S5 E Duct 36 Nexya S5 E Duct 36T Nexya S4 E Duct 48T* OS-SANDH18EI OS-SANDH24EI OS-SANDH36EI OS-SANDH36EI OS-SANDH48EI 8021183119152 8021183119169 8021183119176 8021183119176 8021183119183 OS-CANCH18EI OS-CANCH24EI OS-CANCH36EI OS-CANCHT36EI OS-CECITH48EI 8021183119053 8021183119060 8021183119077 8021183119084 8021183116175 kW 2,55/5,275/5,86 3,28/7,034/8,16 2,75/9,958/11,14 2,73/9,974/11,78 4,26/14,07/15,19 kW 2,20/5,569/6,15 2,81/7,62/8,49 2,78/11,723/12,78 2,78/11,245/12,84 3,7/16,12/18,02 kW 0,71/1,53/2,15 0,75/2,178/2,96 0,9/3,041/4,15 0,89/3,04/4,2 1,17/5,15/5,70 kW 0,74/1,501/1,76 0,64/1,9/2,58 0,8/3,16/3,95 0,78/2,877/4 0,95/4,28/5,83 A 3,2/7,1/9,56 4,2/10,2/13,2 4,2/17,5/18,5 1,4/6,5/6,7 1,8/8,3/9,4 A 3,3/6,8/7,7 3,8/9,2/11,6 3,5/14,5/17,5 1,3/5,3/6,4 1,5/6,8/9,2 3,45 3,23 3,27 3,28 2,73 3,71 4,01 3,71 3,91 3,77 kW 2,95 3,7 5 5 6,2 kW 2,95 3,7 5 5 6,2 / kWh/year kWh/year 291 kWh/year kWh/year 1505 kWh/year kWh/year 1434 kWh/year / l/h 1,87 Pdesignc kW 5,4 Pdesignh kW 4,3 Pdesignh kW 5,2 Pdesignh kW / SEER 6,5 SCOP ( A ) 4 SCOP ( W ) 5,1 SCOP ( C ) / LWA dB(A) 58 dB(A) 41/38/34/26 m³/h 911-706-515 m³/h 911-706-515 Pa 25 Pa 0-100 / mm 880x210x674 kg 24,4 mm 1070x280x725 kg 29,6 LWA dB(A) 65 dB(A) 56 m³/h 2100 / mm 805x554x330 kg 32,5 mm 915x615x370 kg inch - mm inch - mm m 35,2 1/4" - 6,35 1/2" - 12,7 30 m 20 m 5 m 3 g/m 12 MPa 4,3-1,7 Type Type R32 GWP 675 kg 1,15 V/F/Hz V/F/Hz One Phase 220240 / 1 / 50 One Phase 220240 / 1 / 50 Pipes 3 x 2,5 mm2 Pipes 4 x 1 mm2 A 13,5 / 401 1890 1647 / 2,34 7,1 5,4 6 / 6,2 4 5,1 / 61 42/40/37/27 1229-1035-825 1229-1035-825 25 0-160 / 1100x249x774 32,3 1305x315x805 39,1 67 60 3500 / 890x673x342 43,9 995x740x398 46,9 3/8" - 9,52 5/8" - 15,9 50 25 5 3 24 4,3-1,7 R32 675 1,5 One Phase 220240 / 1 / 50 One Phase 220240 / 1 / 50 3 x 2,5 mm2 4 x 1 mm2 19 / / / 593 608 808 2940 3080 4263 2690 2745 2949 / / / 3,54 4,19 / 10,5 10,6 14,0 8,4 8,8 12,1 9,8 10 10,7 / / / 6,2 6,1 6,1 4 4 4 5,1 5,1 5,1 / / / 61 61 66 49/48/46/42 49/48/46/42 50/49/47/42 2100-1800-1500 2100-1800-1500 2400-2040-1680 2100-1800-1500 2100-1800-1500 2400-2040-1680 37 37 50 0-160 0-160 0-160 / / / 1360x249x774 1360x249x774 1200x300x874 40,5 40,5 47,6 1570x330x805 1570x330x805 1405x365x915 48,2 48,2 55,8 70 70 72 63 63 66 4000 4000 7500 / / / 946x810x410 946x810x410 952x1333x415 66,9 80,5 106,7 1090x885x500 1090x885x500 1090x1480x495 71,5 85 119,9 3/8" - 9,52 3/8" - 9,52 3/8" - 9,52 5/8" - 15,9 5/8" - 15,9 5/8" - 15,9 75 30 5 3 24 4,3-1,7 R32 675 2,4 One Phase 220240 / 1 / 50 One Phase 220240 / 1 / 50 3 x 2,5 mm2 4 x 1 mm2 22,5 75 30 5 3 24 4,3-1,7 R32 675 2,4 One Phase 220240 / 1 / 50 Three-phase 380-415/3/50 3 x 2,5 mm2 4 x 1 mm2 10 65 30 5 3 24 4,3-1,7 R32 675 2,8 One Phase 220240 / 1 / 50 Three-phase 380-415/3/50 3 x 2,5 mm2 4 x 1 mm2 11,2 DB 32°C DB 17°C DB 30°C DB 0°C DB 50°C DB 24°C DB -15°C HRV UNICO MONO AND MULTISPLIT PORTABLES The declared data relate to the conditions provided for in EN 14511, EN 14825 and EU Delegated Regulation 626/2011. The actual power consumption of the product, in conditions of real use, may differ from what is indicated. The data are subject to change and modification without prior notice. Dehumidification values refer to DB 27°C WB 19°C conditions. The sound pressure values are measured under the following conditions: in semi-anechoic chamber, unit positioned in a free space, measuring device positioned 1.5 metres below the internal unit to which standard ducting of 2 metres (supply) and 1 metre (return) are attached. The sound pressure values of the outdoor units are at the following conditions: in a semi-anechoic chamber, unit positioned in free space, measuring device positioned at a distance of 1 metre (outdoor unit). *Non-hermetically sealed equipment containing fluorinated gases with GWP equivalent of 675. 167 NEXYA COMMERCIAL CASSETTE False ceiling-mounted inverter mono-split air conditioners ducted for large rooms HIGH EFFICIENCY High-performance R32 refrigerant gas with maximum technological efficiency, to reach the energy class A++. DECORATIVE PANEL Equipped with a digital display, it has vents for the ejection of air even at the corners. For greater climate comfort. COMPACT DESIGN Reduced dimensions up to 600x600, in the compact version. INDEPENDENT BLADE CONTROL Independent flap control for greater climate comfort, in sizes from 24 up to 48. FEATURES FUNCTIONS Two models Compact cassettes (with slimline width and length dimensions of only 600x600 mm) and cassettes (with width and length dimensions of more than 600x600 mm and slimline height from 205 mm). Fresh air inlet The internal units of the commercial line are fitted with specific air inlets to introduce fresh or outdoor air into the product. Condensaton lift pump The internal units are fitted with a condensation pump. Remote ON-OFF All units in the commercial line are fitted with terminals to control the remote switching on and off of the unit via an external device. Contact alarm The units in the commercial line have a contact that allows the alarm status of the product to be synchronised with an external device. Hydrophilic Aluminium coating Suitable for installation in coastal or particularly humid areas, thanks to its excellent anti-corrosion properties. With equivalent environmental conditions, the new coating of the condensers guarantees them a longevity exceeding 7 times that of the traditional models. · Cooling, heating, dehumidification and ventilation · Auto, Co, Sleep, Silent and Turbo functions · 24h timer: for scheduling switch on and off. · Follow Me function: precise temperature detection at the remote control location. · Gear function: 3 power options (50-75-100%) to optimise energy consumption. · Short cut function: to automatically return to the previous settings. · Anti dust filter: to capture dust and pollen. · Self-Clean function: automatically cleans and dries the evaporator eliminating dust, mould and grease to ensure clean air in the room. 168 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS DESIGN LOAD (EN 14825) SEASONAL EFFICIENCY (EN14825) INDOOR UNIT OUTDOOR UNIT DECORATIVE PANEL COOLING CIRCUIT INDOOR UNIT CODE INDOOR UNIT EAN CODE OUTDOOR UNIT CODE OUTDOOR UNIT EAN CODE Output power in cooling mode (min/rated/max) Output power in heating mode (min/rated/max) Absorbed power in cooling mode (min/rated/max) Absorbed power in heating mode (min/rated/max) Current consumption in cooling mode (min/rated/max) Current consumption in heating mode (min/rated/max) EER COP Maximum power consumption in cooling mode Maximum power consumption in heating mode Energy efficiency class in cooling Energy efficiency class in heating mode - Average season Energy efficiency class in heating mode - Warmer season Energy efficiency class in heating mode - Cold season Energy consumption in cooling mode Annual energy consumption in heating mode - Average season Annual energy consumption in heating mode - Warmer season Annual energy consumption in heating mode - Cold season Dehumidification capacity Cooling Heating / Average Heating / Warmer Heating / Colder Cooling Heating / Average Heating / Warmer Heating / Colder Sound power (EN 12102) Sound pressure (max/med/min/silence) Air flow rate in cooling mode (max/med/min) Air flow rate in heating mode (max/med/min) Degree of protection Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Sound power (EN 12102) Sound pressure Air flow rate (max) Degree of protection Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Connecting liquid pipeline diameter Connecting gas pipeline diameter Maximum piping length Maximum height difference Covered piping length from pre-load Piping recommended minimum length Refrigerant increase (over 5 m of pipes) Maximum operating pressure Refrigerant gas* Global warming potential Refrigerant gas charge Supply voltage indoor unit ELECTRICAL CONNECTIONS Indoor ambient temperature Outdoor ambient temperature Supply voltage outdoor unit Outdoor unit power supply connection Indoor - Outdoor unit connection Max Current LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Nexya S5 E Cassette Nexya S5 E Cassette Nexya S5 E Cassette Nexya S5 E Cassette Nexya S5 E Cassette Compact 18 24 36 36T 48T OS-K/SANCH18EI OS-K/SANCH24EI OS-K/SANCH36EI OS-K/SANCH36EI OS-K/SANCH48EI 8021183119336 8021183119343 8021183119350 8021183119350 8021183119367 OS-CANCH18EI OS-CANCH24EI OS-CANCH36EI OS-CANCHT36EI OS-CANCHT48EI 8021183119053 8021183119060 8021183119077 8021183119084 8021183119091 kW 2,9/5,28/5,59 3,3/6,155/7,91 2,7/9,952/11,43 2,7/10,01/11,43 3,52-14,07-15,83 kW 2,37/5,18/6,10 2,81/7,62/8,94 2,78/11,137/12,3 2,78/11,137/12,66 4,1-16,12-17,29 kW 0,72/1,633/2,088 0,78/1,876/2,748 0,9/2,989/4,2 0,89/3,044/4,15 0,8-4,65-5,9 kW 0,7/1,38/1,93 0,61/1,9/2,7 0,8/3/3,95 0,78/3/4 0,9-4,58-5,5 A 3,2/7,2/9,2 4,2/10,2/12 4,2/17,5/18,5 1,4/6,5/6,5 1,8-8,1-10,2 A 3,1/6,8/8,5 3,6/8,5/12,1 3,5/13,5/17,5 1,3/5/6,4 1,9-8-9,5 3,23 3,28 3,33 3,29 3,03 3,75 4,01 3,71 3,71 3,52 kW 2,95 3,7 5 5 6,9 kW 2,95 3,7 5 5 6,9 / kWh/year kWh/year 294 kWh/year kWh/year 1470 kWh/year kWh/year 1575 kWh/year / l/h 2,29 Pdesignc kW 5,3 Pdesignh kW 4,2 Pdesignh kW 5,4 Pdesignh kW / SEER 6,3 SCOP ( A ) 4 SCOP ( W ) 4,8 SCOP ( C ) / LWA dB(A) 57 dB(A) 43/39/35/- m³/h 720-620-500 m³/h 720-620-500 / mm 570x260x570 kg 16 mm 662x317x662 kg 20,6 LWA dB(A) 63 dB(A) 59 m³/h 2100 / mm 805x554x330 kg 32,5 mm 915x615x370 kg 35,2 mm 647x50x647 kg 2,5 mm 715x123x715 kg 4,5 inch - mm 1/4" - 6,35 inch - mm 1/2" - 12,7 m 30 m 20 m 5 m 3 g/m 12 MPa 4,3-1,7 Type Type R32 GWP 675 kg 1,15 V/F/Hz V/F/Hz One Phase 220240 / 1 / 50 One Phase 220240 / 1 / 50 Pipes 3 x 2,5 mm2 Pipes 4 x 1 mm2 A 13,5 / 395 2100 1729 / 2,37 7 6 6,3 / 6,2 4 5,1 / 57 45/42/39/1300-1140-1000 1300-1140-1000 / 830x205x830 21,6 910x250x910 25,4 67 60 3500 / 890x673x342 43,9 995x740x398 46,9 950x55x950 6,0 1035x90x1035 9,0 3/8" - 9,52 5/8" - 15,9 50 25 5 3 24 4,3-1,7 R32 675 1,5 One Phase 220240 / 1 / 50 One Phase 220240 / 1 / 50 3 x 2,5 mm2 4 x 1,5 mm2 19 / / 549 589 2975 2870 2773 2773 / / 3,35 3,66 10,5 10,5 8,5 8,2 10,1 10,1 / / 6,7 6,4 4 4 5,1 5,1 / / 63 63 50/47/44/- 50/47/44/- 1700-1550-1380 1800-1600-1400 1700-1550-1380 1800-1600-1400 / / 830x245x830 830x245x830 27,2 27,2 910x290x910 910x290x910 31,2 31,2 70 70 63 63 4000 4000 / / 946x810x410 946x810x410 66,9 80,5 1090x885x500 1090x885x500 71,5 85 950x55x950 950x55x950 6,0 6,0 1035x90x1035 1035x90x1035 9,0 9,0 3/8" - 9,52 3/8" - 9,52 5/8" - 15,9 5/8" - 15,9 75 75 30 30 5 5 3 3 24 24 4,3-1,7 4,3-1,7 R32 R32 675 675 2,4 2,4 One Phase 220240 / 1 / 50 One Phase 220240 / 1 / 50 One Phase 220240 / 1 / 50 Three-phase 380-415/3/50 3 x 2,5 mm2 3 x 2,5 mm2 4 x 1,5 mm2 4 x 1,5 mm2 22,5 10 / 810 3860 3360 / 5,32 14 11 12 / 6,1 4 5 / 65 51/48/46/1970-1780-1580 1970-1780-1580 / 830x287x830 29,3 910x330x910 33,5 73 64 7500 / 952x1333x415 103,7 1095x1480x495 118,3 950x55x950 6,0 1035x90x1035 9,0 3/8" - 9,52 5/8" - 15,9 75 30 5 3 24 4,3-1,7 R32 675 2,9 One Phase 220240 / 1 / 50 Three-phase 380-415/3/50 3 x 2,5 mm2 4 x 1,5 mm2 13 DB 32°C DB 17°C DB 30°C DB 0°C DB 50°C DB 24°C DB -15°C HRV UNICO MONO AND MULTISPLIT PORTABLES The declared data relate to the conditions provided for in EN 14511, EN 14825 and EU Delegated Regulation 626/2011. The actual power consumption of the product, in conditions of real use, may differ from what is indicated. The data are subject to change and modification without prior notice. Dehumidification values refer to DB 27°C WB 19°C conditions. The sound pressure values are at the following conditions: in semi-anechoic chamber, unit positioned in a free space, measuring device positioned 1.4 metres below the internal unit. The sound pressure values of the outdoor units are at the following conditions: in a semi-anechoic chamber, unit positioned in free space, measuring device positioned at a distance of 1 metre (outdoor unit). *Non-hermetically sealed equipment containing fluorinated gases with GWP equivalent of 675. 169 NEXYA COMMERCIAL CEILING Energy efficient inverter air conditioners. HIGH EFFICIENCY High-performance R32 refrigerant gas with maximum technological efficiency, to reach the energy class A++. FEATURES FUNCTIONS Energy-efficient inverter technology with low-GWP R32 refrigerant gas. Remote ON-OFF All units in the commercial line are fitted with terminals to control the remote switching on and off of the unit via an external device. Alarm contact The units in the commercial line have a contact that allows the alarm status of the product to be synchronised with an external device. Hydrophilic Aluminium coating Suitable for installation in coastal or particularly humid areas, thanks to its excellent anti-corrosion properties. With equivalent environmental conditions, the new coating of the condensers guarantees them a longevity exceeding 7 times that of the traditional models. · Cooling, heating, dehumidification and ventilation · Auto, Co, Sleep, Silent and Turbo functions · 24h timer: for scheduling switch on and off. · Swing function: automatically regulates the air flow (horizontal and vertical) · Follow Me function: precise temperature detection at the remote control location. · Gear function: 3 power options (50-75-100%) to optimise energy consumption. · Short cut function: to automatically return to the previous settings. · Anti dust filter: to capture dust and pollen. · Self-Clean function: automatically cleans and dries the evaporator eliminating dust, mould and grease to ensure clean air in the room. 170 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS HRV DESIGN LOAD (EN 14825) SEASONAL EFFICIENCY (EN14825) INDOOR UNIT OUTDOOR UNIT COOLING CIRCUIT INDOOR UNIT CODE INDOOR UNIT EAN CODE OUTDOOR UNIT CODE OUTDOOR UNIT EAN CODE Output power in cooling mode (min/rated/max) Output power in heating mode (min/rated/max) Absorbed power in cooling mode (min/rated/max) Absorbed power in heating mode (min/rated/max) Current consumption in cooling mode (min/rated/max) Current consumption in heating mode (min/rated/max) EER COP Maximum power consumption in cooling mode Maximum power consumption in heating mode Energy efficiency class in cooling Energy efficiency class in heating mode - Average season Energy efficiency class in heating mode - Warmer season Energy efficiency class in heating mode - Cold season Energy consumption in cooling mode Annual energy consumption in heating mode - Average season Annual energy consumption in heating mode - Warmer season Annual energy consumption in heating mode - Cold season Dehumidification capacity Cooling Heating / Average Heating / Warmer Heating / Colder Cooling Heating / Average Heating / Warmer Heating / Colder Sound power (EN 12102) Sound pressure (max/med/min/silence) Air flow rate in cooling mode (max/med/min) Air flow rate in heating mode (max/med/min) Degree of protection Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Sound power (EN 12102) Sound pressure Air flow rate (max) Degree of protection Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Connecting liquid pipeline diameter Connecting gas pipeline diameter Maximum piping length Maximum height difference Covered piping length from pre-load Piping recommended minimum length Refrigerant increase (over 5 m of pipes) Maximum operating pressure Refrigerant gas* Global warming potential Refrigerant gas charge Supply voltage indoor unit ELECTRICAL CONNECTIONS Supply voltage outdoor unit Outdoor unit power supply connection Indoor - Outdoor unit connection Max Current Nexya S5 E Ceiling 18 Nexya S5 E Ceiling 24 Nexya S5 E Ceiling 36 Nexya S5 E Ceiling 36T Nexya S5 E Ceiling 48T OS-SANFH18EI OS-SANFH24EI OS-SANFH36EI OS-SANFH36EI OS-SANFH48EI 8021183119190 8021183119206 8021183119213 8021183119213 8021183119220 OS-CANCH18EI OS-CANCH24EI OS-CANCH36EI OS-CANCHT36EI OS-CANCHT48EI 8021183119053 8021183119060 8021183119077 8021183119084 8021183119091 kW 2,71/5,275/5,86 3,22/6,804/7,77 2,73/10,109/11,43 2,73/10,092/11,78 3,52/14,07/15,24 kW 2,42/5,569/6,30 2,72/7,62/8,29 2,78/11,723/12,78 2,81/11,714/12,78 4,1/16,12/17 kW 0,67/1,45/2,03 0,747/2,062/2,93 0,9/3,058/4,25 0,89/3,103/4,3 0,9/5/5,95 kW 0,54/1,5/1,64 0,65/2,05/2,85 0,8/3,16/3,95 0,78/3,085/3,95 1/5,1/6,05 A 3,2/6/9 3,9/10,54/13,1 4,2/17/19 1,4/6,3/6,8 1,9/8,8/10,3 A 2,7/6,6/7,3 3,5/9,5/12,7 3,5/15/17,5 1,3/5,4/6,2 2,1/8,9/10,5 3,64 3,3 3,31 3,25 2,81 3,71 3,72 3,71 3,8 3,16 kW 2,95 3,7 5 5 6,9 kW 2,95 3,7 5 5 6,9 / kWh/year kWh/year 305 kWh/year kWh/year 1400 kWh/year kWh/year 1400 kWh/year / l/h 1,78 Pdesignc kW 5,4 Pdesignh kW 4 Pdesignh kW 5,1 Pdesignh kW / SEER 6,2 SCOP ( A ) 4 SCOP ( W ) 5,1 SCOP ( C ) / LWA dB(A) 57 dB(A) 43/41/36/- m³/h 958-839-723 m³/h 958-839-723 / mm 1068x235x675 kg 28,0 mm 1145x318x755 kg 33,3 LWA dB(A) 65 dB(A) 59 m³/h 2100 / mm 805x554x330 kg 32,5 mm 915x615x370 kg 35,2 inch - mm 1/4" - 6,35 inch - mm 1/2" - 12,7 m 30 m 20 m 5 m 3 g/m 12 MPa 4,3-1,7 Type Type R32 GWP 675 kg 1,15 V/F/Hz V/F/Hz One Phase 220240 / 1 / 50 One Phase 220240 / 1 / 50 Pipes 3 x 2,5 mm2 Pipes 4 x 1 mm2 A 13,5 / 413 1925 1592 / 2,72 7,2 5,5 5,8 / 6,1 4 5,1 / 55 49/46/43/1192-1023-853 1192-1023-853 / 1068x235x675 28,0 1145x318x755 33,1 66 60 3500 / 890x673x342 43,9 995x740x398 46,9 3/8" - 9,52 5/8" - 15,9 50 25 5 3 24 4,3-1,7 R32 675 1,5 One Phase 220240 / 1 / 50 One Phase 220240 / 1 / 50 3 x 2,5 mm2 4 x 1 mm2 19 / 574 2937 2800 / 3,28 10,5 8,6 10,2 / 6,2 4 5,1 / 64 50/48/44/1955-1728-1504 1955-1728-1504 / 1650x235x675 41,5 1725x318x755 48 68 63 4000 / 946x810x410 66,9 1090x885x500 71,5 3/8" - 9,52 5/8" - 15,9 75 30 5 3 24 4,3-1,7 R32 675 2,4 One Phase 220240 / 1 / 50 One Phase 220240 / 1 / 50 3 x 2,5 mm2 4 x 1 mm2 22,5 / 592 3010 2745 / 4,19 10,5 8,6 10 / 6,2 4 5,1 / 64 50/47/44/1955-1728-1504 1955-1728-1504 / 1650x235x675 41,5 1725x318x755 48,0 70 63 4000 / 946x810x410 80,5 1090x885x500 85,0 3/8" - 9,52 5/8" - 15,9 75 30 5 3 24 4,3-1,7 R32 675 2,4 One Phase 220240 / 1 / 50 Three-phase 380-415/3/50 3 x 2,5 mm2 4 x 1 mm2 10 / 809 4079 3211 / 5,45 14 11,2 11,7 / 6,1 4 5,1 / 67 53/50/45/2100-1850-1600 2100-1850-1600 / 1650x235x675 41,7 1725x318x755 48,5 73 64 7500 / 952x1333x415 103,7 1095x1480x495 118,3 3/8" - 9,52 5/8" - 15,9 75 30 5 3 24 4,3-1,7 R32 675 2,9 One Phase 220240 / 1 / 50 Three-phase 380-415/3/50 3 x 2,5 mm2 4 x 1 mm2 13 Indoor ambient temperature Outdoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating DB 32°C DB 17°C DB 30°C DB 0°C DB 50°C DB 24°C DB -15°C The declared data relate to the conditions provided for in EN 14511, EN 14825 and EU Delegated Regulation 626/2011. The actual power consumption of the product, in conditions of real use, may differ from what is indicated. The data are subject to change and modification without prior notice. Dehumidification values refer to DB 27°C WB 19°C conditions. The sound pressure values are measured under the following conditions: in semi-anechoic chamber, unit positioned in a free space, measuring device positioned 1 metre below the internal unit and 1 metre from the front of the internal unit. The sound pressure values of the outdoor units are measured under the following conditions: in a semi-anechoic chamber, unit positioned in free space, measuring device positioned at a distance of 1 metre (outdoor unit). *Non-hermetically sealed equipment containing fluorinated gases with GWP equivalent of 675. UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 171 NEXYA MULTISPLIT Energy efficient multisplit inverter air conditioners FEATURES FUNCTIONS Energy-efficient inverter technology with low GWP R32 refrigerant. Available in the two, three, four and five room versions, for air conditioning up to five rooms with the use of a single outdoor motor. The system is modular: systems can be designed using wall-mounted, duct or cassette units and selecting the right size according to the thermal load of the system. · Cooling, heating, dehumidification and ventilation · Auto function: modulates the operating parameters in relation to the room temperature. · Sleep function: gradually increases the set temperature and ensures reduced noise for better night-time well-being. Check Olimpiasplendid.it for the combinations that can access the economic incentives. 172 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA OUTDOOR UNIT CODE EAN CODE Electrical power supply V/F/Hz Capacity (min / rated / max) kW Absorbed power (Nom/Min-Max) kW Current consumption (Nom/Min-Max) A Cooling Theoretical Load (PdesignC) kW SEER Energy efficiency class Annual energy consumption kWh/A Capacity (min / rated / max) kW Absorbed power (Nom/Min-Max) kW Heating Current consumption (Nom/Min-Max) Theoretical Load (PdesignH) (average climate warmer climate) Scop (average climate - warmer climate) Energy efficiency class (average climate - warmer climate) Annual energy consumption (average climate warmer climate) Energy efficiency E.E.R./C.O.P. A kW medium zone / hot zone kWh/A W/W Dimensions (WxHxD) (without packaging) mm Weight (without packaging) kg Dimensions (WxHxD) (with packaging) mm Weight (with packaging) kg Outdoor unit Air flow rate m³/h Sound pressure (max) dB(A) Sound power level (max) dB(A) Compressor Type Diameter of tube in liquid connection line mm Diameter of tube in gas connection line mm Covered piping length from pre-load m Piping recommended minimum length m Dimensions and limitations of the cooling circuit Piping Equivalent length (max) Piping Equivalent max. length (single branch of piping) m m Increase of Refrigerant g/m Difference in level (Max) (outdoor unit in higher position that indoor units m Difference in level (Max) (outdoor unit in lower position that indoor units) m Difference in level (Max) (elevation difference between indoor units) m Refrigerant gas * Refrigerant fluid Electrical connections GWP Refrigerant gas charge Maximum applied pressure high pressure side/low pressure side Main power supply Max Power absorption Max Current kg MPa V/F/Hz W A Operational Outdoor temperature in cooling (Min-Max) limits Outdoor temperature in heating (Min-Max) °C B.S. °C B.U. ODU Nexya S5 E Dual Inverter 14 OS-CANMH14EI 8021183119107 One Phase 220-240 / 1 / 50 1,76-4,1-4,92 1,27(0,44-1,59) 5,47(1,89-6,84) 4,1 6,1 235 1,89-4,4-5,28 1,19(0,42-1,48) 5,12(1,81-6,37) 3,9-4,1 3,8-5,1 1425-1125 3,23/3,71 805x554x330 31,6 915x615x370 34,7 2100 56 65 rotary 2x6,35 2x9,52 15 3 40 25 12 15 15 10 R32 675 1,1 4,3/1,7 One Phase 220-240 / 1 / 50 2750 12 -/+50 -15/+24 ODU Nexya S5 E Dual Inverter 18 OS-CANMH18EI 8021183119114 One Phase 220-240 / 1 / 50 2,12-5,3-6,41 1,64(0,54-2,05) 7,06(2,32-8,82) 5,3 6,1 306 2,23-5,57-6,68 1,5(0,51-1,88) 6,46(2,20-8,09) 4,3-5 4-5,1 1501-1373 3,23/3,71 805x554x330 35,0 915x615x370 38,0 2100 56 65 rotary 2x6,35 2x9,52 15 3 40 25 12 15 15 10 R32 675 1,25 4,3/1,7 One Phase 220-240 / 1 / 50 3050 13 -/+50 -15/+24 ODU Nexya S5 E Trial Inverter 21 OS-CANMH21EI 8021183119121 One Phase 220-240 / 1 / 50 2,44-6,10-7,32 1,89(0,68-2,36) 8,14(2,93-10,16) 6,1 6,1 350 2,26-6,45-7,74 1,74(0,63-2,17) 7,49(2,71-9,34) 5,1-5,1 4,0-5,1 1785-1400 3,23-3,71 890x673x342 43,3 1030x750x438 47,1 3000 58 66 rotary 3x6,35 3x9,52 22,5 3 60 30 12 15 15 10 R32 675 1,5 4,3-1,7 One Phase 220-240 / 1 / 50 3910 17 - /+50 -15/+24 ODU Nexya S4 E Quadri Inverter 28 OS-CEMYH28EI 8021183116052 One Phase 220-240 / 1 / 50 2,79-7,98-9,65 2,17(0,74-2,71) 9,34(3,19-11,66) 8,02 6,8 412 2,84-8,12-9,82 2,01(0,68-2,52) 8,65(2,93-10,85) 6,25-7,05 4,0-5,06 2209-1947 3,67-4,03 946x810x410 62,1 1090x875x500 67,7 3800 61 67 rotary 4x6,35 3x9,52+1x12,7 30 3 80 35 12 15 15 10 R32 675 2,1 4,3/1,7 One Phase 220240 / 1 / 50 4150 19 -/+50 -15/+24 ODU Nexya S5 E Penta Inverter 42 OS-CANMH42EI 8021183119138 One Phase 220-240 / 1 / 50 4,18-12,30-14,00 3,81(1,03-4,57) 16,4(4,43-19,67) 12,3 6,1 706 4,18-12,30-14,94 3,32(0,90-4,14) 14,29(3,87-17,82) 9,5-10,40 3,5-5,1 3800-2855 3,23-3,71 946x810x410 74,1 1090x875x500 79,5 3850 64 69 rotary 5x6,35 4x9,52+1x12,7 37,5 3 80 35 12 15 15 10 R32 675 2,9 4,3-1,7 One Phase 220-240 / 1 / 50 4700 22 -/+50 -15/+24 The declared data relate to the conditions envisaged in EN 14511, EN 14825 and EU Delegated Regulation 626/2011 for the combination capable of expressing the highest energy class. For the energy class and performance of the individual combinations, refer to the selection tables on the website www.olimpiasplendid.it and to the energy labels of the specific combination. The actual power consumption of the product, in conditions of real use, may differ from what is indicated. The data are subject to change and modification without prior notice. The sound pressure values of the Nexya S4 range are measured under the following conditions: ambient sound pressure level equal to 0 dB (pressure equal to 20Pa), unit positioned in free space, measuring device positioned at a distance of 1.5 metres (outdoor unit). The sound pressure values of the Nexya S5 range are measured under the following conditions: in semi-anechoic chamber, unit positioned in free space, measuring device positioned at a distance of 1 metres (outdoor unit). * Non hermetically sealed equipment containing fluorinated GAS with GWP equivalent to 675. HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 173 Wall internal units Indoor unit Piping dimensions Operational limits TECHNICAL DATA PRODUCT CODE EAN CODE Electrical power supply Cooling Heating Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Air flow rate (min/rated/max) Sound pressure (silent/min/med/max) Sound power level Max (EN 12102) Diameter of tube in liquid connection line Diameter of tube in gas connection line Indoor temperature in cooling (Min-Max) Indoor temperature in heating (Min-Max) V/F/Hz kW (Nom) kW (Nom) mm kg mm kg m³/h dB(A) dB(A) inch - mm inch - mm °C B.S. °C B.S. IDU Nexya S4 E Inverter 9 OS-SENEH09EI 8021183114928 220-240/1/50 2,64 2,93 805x285x194 7,5 870x360x270 9,7 340-460-520 21-26-30-40 54 1/4" - 6,35 3/8" - 9,52 +17/+32 0/+30 IDU Nexya S4 E Inverter 12 OS-SENEH12EI 8021183114935 220-240/1/50 3,52 3,81 805x285x194 7,5 870x360x270 9,7 360-500-600 22-26-34-40 54 1/4" - 6,35 3/8" - 9,52 +17/+32 0/+30 IDU Nexya S4 E inverter 18 OS-SENEH18EI 8021183114942 220-240/1/50 5,27 4,97 957x302x213 10,0 1035x385x295 13,0 340-460-520 21-26-30-40 55 1/4" - 6,35 1/2" - 12,7 +17/+32 0/+30 The declared data relate to the conditions provided for in EN 14511, EN 14825 and EU Delegated Regulation 626/2011. The actual power consumption of the product, in conditions of real use, may differ from what is indicated. The data are subject to change and modification without prior notice. The sound pressure values of the Nexya S4 range are measured under the following conditions: ambient sound pressure level equal to 0 dB (pressure equal to 20Pa), unit positioned in free space, measuring device positioned at a distance of 1 metre and 0.8 metres below the internal unit. Duct and cassette internal units Indoor unit Decorative Panel Piping dimensions Operational limits TECHNICAL DATA PRODUCT CODE EAN CODE Electrical power supply Cooling Heating Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Air flow rate (min/rated/max) Sound pressure (min/rated/max) Sound power level Max (EN 12102) Fan pressure Fan pressure adjustment field Dimensions (WxHxD) (without packaging) Weight (without packaging) Dimensions (WxHxD) (with packaging) Weight (with packaging) Diameter of tube in liquid connection line Diameter of tube in gas connection line Indoor temperature in cooling (Min-Max) Indoor temperature in heating (Min-Max) NEW NEW V/F/Hz kW (Nom) kW (Nom) MM kg mm kg m³/h dB(A) dB(A) Pa Pa mm kg mm kg inch - mm inch - mm °C B.S. °C B.S. IDU Nexya S5 E Duct 9 OS-SANDH09EI 8021183121018 220-240/1/50 2,64 2,93 700x200x506 17,8 860x285x540 21,5 230-340-500 28-34-40 58 25 0-40 1/4" - 6,35 3/8" - 9,52 +16/+32 0/+30 IDU Nexya S5 E Duct 12 IDU Nexya S5 E Duct 18 IDU Nexya S5 E Cassette Compact 9 OS-SANDH12EI OS-SANDH18EI OS-K/SANCH09EI 8021183119145 8021183119152 8021183121070 220-240/1/50 220-240/1/50 220-240/1/50 3,52 5,28 2,64 3,81 5,57 2,93 700x200x506 880x210x674 570x260x570 17,8 24,4 14,5 860x285x540 1070x280x725 640x295x675 21,5 29,6 17,3 300-480-600 515-706-911 450-500-580 29-30-34 34-38-41 29-33-38 57 58 53 25 25 - 0-60 0-100 - - - 647x50x647 - - 2,5 - - 715x123x715 - - 4,5 1/4" - 6,35 1/4" - 6,35 1/4" - 6,35 3/8" - 9,52 1/2" - 12,7 3/8" - 9,52 +16/+32 +16/+32 +16/+32 0/+30 0/+30 0/+30 IDU Nexya S5 E Cassette Compact 12 OS-K/SANCH12EI 8021183119329 220-240/1/50 3,52 3,81 570x260x570 16,3 655x290x655 20,4 420-510-620 33-36-41 56 647x50x647 2,5 715x123x715 4,5 1/4" - 6,35 3/8" - 9,52 +17/+32 0/+30 IDU Nexya S5 E Cassette Compact 18 OS-K/SANCH18EI 8021183119336 220-240/1/50 5,28 5,57 570x260x570 16,0 662x317x662 20,6 500-620-720 35-39-43 57 647x50x647 2,5 715x123x715 4,5 1/4" - 6,35 1/2" - 12,7 +17/+32 0/+30 The declared data relate to the conditions provided for in EN 14511, EN 14825 and EU Delegated Regulation 626/2011. The actual power consumption of the product, in conditions of real use, may differ from what is indicated. The data are subject to change and modification without prior notice. The sound pressure values of the Duct S5 range are at the following conditions: in semi-anechoic chamber, unit positioned in a free space, measuring device positioned 1.5 meters below the internal unit to which are applied standard ducts with a length of 2 meters (delivery) and 1 meter (return). The declared data relate to the conditions provided for in EN 14511, EN 14825 and EU Delegated Regulation 626/2011. The actual power consumption of the product, in conditions of real use, may differ from what is indicated. The data are subject to change and modification without prior notice. The sound pressure values of the Cassette S5 range are measured under the following conditions: in semi-anechoic chamber, unit positioned in free space, measuring device positioned at a distance of 1.4 metres below the internal unit. 174 Catalogue 2024 | January edition BMS HEAT PUMPS Combination chart Download the complete combinations tables The table shows the possible general combinations of Nexya Multisplit outdoor units. Depending on the specific models of internal units (wall, duct, cassette), always check the feasible combinations, also available on-line in the download area of the website Olimpiasplendid.it. Installation of the multi-split pipes A B C D E 15 m Between upper indoor unit and outdoor unit (lower) 10 m Between upper indoor unit and lower indoor unit Maximum distance single pipes Indoor unit to Outdoor unit DUAL TRIAL QUADRI PENTA 25 m 30 m 35 m 35 m Total length A+B+C+D+E DUAL TRIAL 40 m 60 m QUADRI 80 m PENTA 80 m FAN COIL UNITS 15 m Between lower indoor unit and outdoor unit (upper) HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 175 Twin System The twin configuration for improved air distribution A complete system, intended for small commercial businesses, to improve air diffusion through the connection of two internal units, of the same power, to an outdoor unit. The internal units are compatible with the Twin System and designed to be installed in one room. The control allows you to control the main unit while the secondary (slave) unit mirrors the on/off settings, set point, function mode and fan speed. POSSIBLE COMBINATIONS OUTDOOR UNIT UE Nexya S5 E Commercial 24 (OS-CANCH24EI) UE Nexya S5 E Commercial 36 monofase (OS-CANCH36EI) UE Nexya S5 E Commercial 48 trifase (OS-CANCHT48EI) INDOOR UNIT 1 UI Nexya S5 E Duct 12 (OS-SANDH12EI) UI Nexya S5 E Ceiling 18 (OS-SANFH18EI) UI Nexya S5 E Cassette 24 (OS-K/SANCH24EI) INDOOR UNIT 2 UI Nexya S5 E Duct 12 (OS-SANDH12EI) UI Nexya S5 E Ceiling 18 (OS-SANFH18EI) UI Nexya S5 E Cassette 24 (OS-K/SANCH24EI) PIPE LENGTH LIMITS 12K+12K 25 Pipe length (m) 18K+18K 30 L+Max (L1, L2) H2 24K+24K 50 PIPE LENGTH H1 L1 L2 L DIFFERENCE IN HEIGHT Single line maximum length (m) 15 L1,L2 Max difference between the two lines L1-L2 10 L1-L2 Max difference in height between internal unit and outdoor unit 20 H1 Max difference in height between the two internal units 0,5 H2 The Y-joints required for the Twin connection are not supplied by the manufacturer but are the responsibility of the installer. Additional installation information is available in the download area of the website Olimpiasplendid.it. 176 Catalogue 2024 | January edition BMS HEAT PUMPS Accessories B0969 B0970 B1020 4-wire wall-mounted remote control Compatible with: UI NEXYA ENERGY E UI NEXYA S4 E UI NEXYA S5 E DUCT UI NEXYA S5 E CASSETTE UI NEXYA S5 E CEILING Wi-Fi disc kit Disc containing a special USB key for Wi-Fi integration. For wall/ceiling installation outside the internal unit. Compatible with: UI NEXYA ENERGY E UI NEXYA S4 E UI NEXYA S5 E DUCT UI NEXYA S5 E CASSETTE 18 UI NEXYA S5 E CEILING Wi-Fi key kit USB key for Wi-Fi integration. Compatible with: UI NEXYA ENERGY E UI NEXYA S4 E UI NEXYA S5 E DUCT UI NEXYA S5 E CASSETTE 24 UI NEXYA S5 E CEILING FAN COIL UNITS HRV UNICO MONO AND MULTISPLIT PORTABLES Standard accessory | Optional accessory | Required accessory | Accessory not compatible Catalogue 2024 | January edition 177 DOLCECLIMA Portable air conditioners Technology and design for a climate that you take with you Thanks to Olimpia Splendid's design innovation, air diffusion is optimised. And the aesthetics is diversified, to suit every interior style. Olimpia Splendid's Blue Air Technology To obtain the maximum comfort of use, Dolceclima portable air conditioners contain an innovative technology that generates a high and deep air jet (up to 4 meters high and 3 wide), which does not directly affect the occupants of the room, but contributes to the diffusion of a homogeneous temperature in the environment. Behind every design, an Italian signature Sebastiano Ercoli, Alessandro Garlandini and Alessio Abdolahian are just some of the Italian brands that have worked on the aesthetics of the Dolceclima portable air conditioners. Soft lines with a retro style are contrasted with extremely clean and rigorous shapes, to propose different designs that meet the unique styles of each home. 180 Catalogue 2024 | January edition BMS HEAT PUMPS Portable air conditioners DOLCECLIMA ARIA 8 The super compact portable model. 2.1 kW of power DOLCECLIMA SILENT S1 10 P The portable model with the best air diffusion. 2.6 kW of power DOLCECLIMA SILENT 12 A+ WIFI The most efficient portable model. 2.7 kW of power DOLCECLIMA AIR PRO 14 HP WIFI The powerful portable model in heat pump. 3.5 kW of power Energy efficiency classes in cooling, depending on the operating limit conditions of each model. Dolceclima Aria 8 (02266) NEW Dolceclima Silent S1 10 P (02059) NEW Dolceclima Silent 12 A+ Wifi (02141) Dolceclima Air Pro 14 HP Wifi (02029) FAN COIL UNITS HRV UNICO MONO AND MULTISPLIT OS Comfort In-depth analysis on control from smartphones and tablets Dolceclima portable air conditioners, equipped with integrated Wi-Fi, can be controlled easily, inside and outside the home, even from smartphones and tablets. To activate them and set the main functions, simply download the compatible iOS or Android application. The OS Comfort application allows you to manage one or more portable air conditioners installed in the home, to display the room temperature and to set the main modes (cooling, heating, dehumidification, ventilation), as well as to program the on and off timers. Catalogue 2024 | January edition 181 PORTABLES NEW DOLCECLIMA ARIA 8 8,000 BTU/h* of pressure for small places and highly practical SPACE SAVING The most compact portable model in the range (only 31 cm wide and 68 cm high) for summer comfort that's even easier to bring with you. TOUCHSCREEN DISPLAY Touch-screen control panel, with minimal aesthetic impact, for immediate control. EXTREMELY PRACTICAL Handles and wheels for easy movement FEATURES · Cooling capacity: 2.1 kW** · Energy class: · Sound pressure: 65 dB (A) · Rated energy efficiency index: EER 2.6** · Coolant gas: R290 · No tank: automatic condensation disposal · Anti-dust filter · LED display and multi-function remote control · Convenient side handles and wheels · Window and air ejection hose kit included. FUNCTIONS · Cooling, dehumidification and ventilation (2 speeds) · 24 H timer · Sleep function: gradually increases the set temperature for greater acoustic comfort. · Auto-Restart function: after a power failure, it restarts at the last function set. * Test conditions: maximum cooling power (35°C / 80% RH). ** Test conditions: according to the EN 145111 standard. 182 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Hourly electricity consumption for single duct (1) cooling mode Hourly electricity consumption for single duct (1) heating mode Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode (1) Maximum absorption in cooling mode (1) Maximum power consumption in heating mode (4) Maximum absorption in heating mode (4) Dehumidification capacity (2) Air flow rate (max/med/min) Fan speed Flexible pipe (lenght x diameter) Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Sound pressure level (min-max) (3) Sound power level (indoor only) (EN 12102) Degree of protection provided by covers Refrigerant gas (5) Global warming potential Refrigerant gas charge Maximum operating pressure Maximum operating pressure (low pressure side) Lower flammable limit Minimum flor area for installation, use and storage Power cable (N° pole x section mm²) Fuse Conformity mark Integrated Wi-fi Prated kW Prated kW PEER kW A PCOP kW A EERd COPd PTO W PSB W QSD kWh/h QSD kWh/h V-F-Hz V W A W A l/h m³/h mm m / ° mm mm kg kg dB(A) LWA dB(A) Type GWP kg MPa MPa LFL kg/m³ m² Indoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating (1) Test conditions: the data refer to the EN14511 standard. (2) Test conditions in dehumidification mode: DB 30°C WB 27.1°C (3) Declaration of test data in a semi-anechoic chamber at a distance of 2 m, minimum pressure in ventilation only (4) High load test and maximum heating output (5) Hermetically sealed equipment. DOLCECLIMA ARIA 8 02266 8021183022667 2,1 0,79 3,5 2,6 - 135 <1 0,79 220/240-1-50 198 / 254 790 4,5 0,71 300 / 0 / 2 1500 x 150 3 / ±30° 305 x 678 x 328 377 x 852 x 340 19 22 51 / 54 65 IP X0 R290 3 0,14 3,0 1,0 0,038 7 3 x 0,75 mm² 3,15 A CE - DB 32°C - WB 24°C DB 16°C - HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 183 NEW DOLCECLIMA SILENT S1 10 10.000 BTU/h* of power and superior comfort BLUE AIR TECHNOLOGY An innovative technology that generates a high and deep air jet, which does not directly affect the occupants of the room, but contributes to the diffusion of a homogeneous temperature in the environment. TOUCHSCREEN DISPLAY Touch-screen control panel, with minimal aesthetic impact, for immediate control. FOLLOW ME The remote control acts as a remote thermostat to ensure correct temperature control in the point where the occupants are present in the room. FEATURES · Refrigeration capacity: 2.6 kW** · Energy rating: · Sound power: 63 dB (A) · Rated energy efficiency index: EER 2.8** · Refrigerant gas: R290 · No tank: automatic condensation disposal · Multifunction remote control and LCD display · Practical side handles and wheels · Air exhaust hose included. FUNCTIONS · Cooling, dehumidification and ventilation (3 speeds) · 24 H timer · Auto function: optimises energy consumption, adjusting the cooling in relation to the room temperature. · Sleep and Silent function: gradually increases the set temperature for greater acoustic comfort. · Turbo function: maximum ventilation speed for super cooling. · Follow Me function: precise temperature detection in the point where the remote control is located. · Auto-Restart function: after a power failure, it restarts at the last function set. * Test conditions: maximum cooling power (35°C / 80% RH). ** Test conditions: according to the EN 145111 standard. 184 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Hourly electricity consumption for single duct (1) cooling mode Hourly electricity consumption for single duct (1) heating mode Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode (1) Maximum absorption in cooling mode (1) Maximum power consumption in heating mode (4) Maximum absorption in heating mode (4) Dehumidification capacity (2) Air flow rate (max/med/min) Fan speed Flexible pipe (lenght x diameter) Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Sound pressure level (min-max) (3) Sound power level (indoor only) (EN 12102) Degree of protection provided by covers Refrigerant gas (5) Global warming potential Refrigerant gas charge Maximum operating pressure Maximum operating pressure (low pressure side) Lower flammable limit Minimum flor area for installation, use and storage Power cable (N° pole x section mm²) Fuse Conformity mark Integrated Wi-fi Prated kW Prated kW PEER kW A PCOP kW A EERd COPd PTO W PSB W QSD kWh/h QSD kWh/h V-F-Hz V W A W A l/h m³/h mm m / ° mm mm kg kg dB(A) LWA dB(A) Type GWP kg MPa MPa LFL kg/m³ m² Indoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating (1) Test conditions: the data refer to the EN14511 standard. (2) Test conditions in dehumidification mode: DB 30°C WB 27.1°C (3) Declaration of test data in a semi-anechoic chamber at a distance of 2 m, minimum pressure in ventilation only (4) High load test and maximum heating output (5) Hermetically sealed equipment. DOLCECLIMA SILENT S1 10 P 02059 8021183020595 2,6 0,93 4,00 2,8 - 1 0,77 0,93 220/240-1-50 198 / 264 1100 5,60 1,5 355/-/3 1500 x 120 8 / ±80° 460 x 762 x 396 496 x 860 x 460 28,0 32,8 -/52 63 IP X0 R290 3 0,23 2,60 1,0 0,038 12 3 x 1,0 / VDE 10AT CE - DB 35°C - WB 32°C DB 17°C - HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 185 DOLCECLIMA SILENT 12 12.000 BTU/h* of power in class A+ Italian design by: HIGH EFFICIENCY Class A+ air conditioner with 11% lower energy consumption (compared to Dolceclima Silent 12 P) for more sustainable comfort BLUE AIR TECHNOLOGY An innovative technology that generates a high and deep air jet, which does not directly affect the occupants of the room, but contributes to the diffusion of a homogeneous temperature in the environment. INTEGRATED WI-FI By downloading the OS Comfort app it is possible to manage all its functions from your smartphone, even when away from home FEATURES · Cooling capacity: 2.7 kW** · Energy class: · Sound pressure: 65 dB (A) · Rated energy efficiency index: EER 3.1** · Coolant gas: R290 · No tank: automatic condensation disposal · Anti-dust filter · Multi-function remote control and LCD display · Convenient side handles and wheels · Air ejection hose kit included. FUNCTIONS · Cooling, dehumidification and ventilation (3 speeds) · 24 H timer · Auto function: optimises energy consumption, adjusting the cooling in relation to the room temperature. · Sleep and Silent function: gradually increases the set temperature for greater acoustic comfort. · Turbo function: maximum ventilation speed for super cooling. · Follow Me function: precise temperature detection in the point where the remote control is located. · Auto-Restart function: after a power failure, it restarts at the last function set. * Test conditions: maximum cooling power (35°C / 80% RH). ** Test conditions: according to the EN 145111 standard. 186 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Hourly electricity consumption for single duct (1) cooling mode Hourly electricity consumption for single duct (1) heating mode Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode (1) Maximum absorption in cooling mode (1) Maximum power consumption in heating mode (4) Maximum absorption in heating mode (4) Dehumidification capacity (2) Air flow rate (max/med/min) Fan speed Flexible pipe (lenght x diameter) Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Sound pressure level (min-max) (3) Sound power level (indoor only) (EN 12102) Degree of protection provided by covers Refrigerant gas (5) Global warming potential Refrigerant gas charge Maximum operating pressure Maximum operating pressure (low pressure side) Lower flammable limit Minimum flor area for installation, use and storage Power cable (N° pole x section mm²) Fuse Conformity mark Integrated Wi-fi Prated kW Prated kW PEER kW A PCOP kW A EERd COPd PTO W PSB W QSD kWh/h QSD kWh/h V-F-Hz V W A W A l/h m³/h mm m / ° mm mm kg kg dB(A) LWA dB(A) Type GWP kg MPa MPa LFL kg/m³ m² Indoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating (1) Test conditions: the data refer to the EN14511 standard. (2) Test conditions in dehumidification mode: DB 30°C WB 27.1°C (3) Declaration of test data in a semi-anechoic chamber at a distance of 2 m, minimum pressure in ventilation only (4) High load test and maximum heating output (5) Hermetically sealed equipment. DOLCECLIMA SILENT 12 A+ WIFI 02141 8021183021417 2,7 0,85 3,8 3,1 - 1,0 1,0 0,85 220/240-1-50 198 / 264 1100 6,3 1,5 358 / 289 / 213 3 1500 x 120 8 / ±80° 460 x 762 x 396 496 x 860 x 460 29,7 35,1 48-52 65 IPX0 R290 3 0,20 2,6 1,0 0,038 10 3 x 1,0 / VDE 10AT CE DB 35°C - WB 32°C DB 17°C - HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 187 DOLCECLIMA AIR PRO 14 HP 14,000 BTU/h* of power. Also in heat pump Italian design by: HEAT PUMP Heat pump air conditioner. Thanks to this feature you you can replace or support traditional heating in intermediate seasons. INTEGRATED WI-FI By downloading the OS Comfort app it is possible to manage all its functions from your smartphone, even when away from home PURE SYSTEM Equipped with a multi-filtering system, consisting of an electrostatic filter (with anti-dust function) and activated carbon filter (effective against unpleasant odours). FEATURES · Rated cooling capacity: 3.5 kW** · Energy class: / in heating · Sound pressure: 64 dB (A) · Rated energy efficiency index: EER 2.6** · Coolant gas: R290 · Anti-dust and activated carbon filter · Multi-function remote control and LCD display · Convenient side handles and wheels · Window and air ejection hose kit included. FUNCTIONS · Cooling, heating, dehumidification and ventilation (3 speeds) · 24 H timer · Eco function: adjusts the cooling in relation to the room temperature to optimise consumption. · Sleep and Silent functions: for greater acoustic comfort. · Turbo function: maximum ventilation speed for super cooling. · Blue Air/Auto function: automatic ventilation speed for optimal air flow management. · Follow Me function: precise temperature detection in the point where the remote control is located. · Auto-Restart function: after a power failure, it restarts at the last function set. * Test conditions: maximum cooling power (35°C / 80% RH). ** Test conditions: according to the EN 145111 standard. 188 Catalogue 2024 | January edition BMS HEAT PUMPS FAN COIL UNITS TECHNICAL DATA PRODUCT CODE EAN CODE Nominal cooling capacity (1) Nominal heating capacity (1) Nominal power consumption for cooling (1) Nominal absorption for cooling (1) Nominal power consumption for heating (1) Nominal absorption for heating (1) Nominal energy efficiency index (1) Nominal efficiency coefficient (1) Energy efficiency class in cooling (1) Energy efficiency class in heating (1) Energy consumption in "thermostat off" mode Energy consumption in "standby" mode (EN 62301) Hourly electricity consumption for single duct (1) cooling mode Hourly electricity consumption for single duct (1) heating mode Supply voltage Supply voltage (min/max) Maximum power consumption in cooling mode (1) Maximum absorption in cooling mode (1) Maximum power consumption in heating mode (4) Maximum absorption in heating mode (4) Dehumidification capacity (2) Air flow rate (max/med/min) Fan speed Flexible pipe (lenght x diameter) Maximun remote control range (distance/angle) Dimensions (WxHxD) (without packaging) Dimensions (WxHxD) (with packaging) Weight (without packaging) Weight (with packaging) Sound pressure level (min-max) (3) Sound power level (indoor only) (EN 12102) Degree of protection provided by covers Refrigerant gas (5) Global warming potential Refrigerant gas charge Maximum operating pressure Maximum operating pressure (low pressure side) Lower flammable limit Minimum flor area for installation, use and storage Power cable (N° pole x section mm²) Fuse Conformity mark Integrated Wi-fi Prated kW Prated kW PEER kW A PCOP kW A EERd COPd PTO W PSB W QSD kWh/h QSD kWh/h V-F-Hz V W A W A l/h m³/h mm m / ° mm mm kg kg dB(A) LWA dB(A) Type GWP kg MPa MPa LFL kg/m³ m² Indoor ambient temperature LIMITS OF OPERATING CONDITIONS Maximum temperature in cooling Minimum temperature in cooling Maximum temperature in heating Minimum temperature in heating (1) Test conditions: the data refer to the EN14511 standard. (2) Test conditions in dehumidification mode: DB 30°C WB 27.1°C (3) Declaration of test data in a semi-anechoic chamber at a distance of 2 m, minimum pressure in ventilation only (4) High load test and maximum heating output (5) Hermetically sealed equipment. DOLCECLIMA AIR PRO 14 HP WIFI 02029 8021183020298 3,5 2,9 1,35 5,90 1,05 5,00 2,6 2,8 1,0 0,5 1,35 1,05 220/240-1-50 198 / 264 1450 8,0 1450 8,0 3,4 420 / 370 / 355 3 1500 x 150 8 / ±80° 490 x 765 x 425 535 x 890 x 487 35 38 50,6 - 52 64 IPX0 R290 3 0,22 2,6 1,0 0,038 11 3 x 1,5 10AT CE DB 35°C - WB 32°C DB 16°C DB 27°C - WB 21,1°C DB 7°C - WB 3,6°C HRV UNICO MONO AND MULTISPLIT PORTABLES Catalogue 2024 | January edition 189 Energy Labels AIR WATER HEAT PUMPS OLIMPIA SPLENDID UE SHERPA S3 E 6 UI SHERPA S3 E SMALL 55 °C 35 °C A+++ A++ A+ A B C D 46 dB A +++ A ++ 04 06 06 07 05 06 kW kW 58 dB 2019 811/2013 Energy efficiency class from A+++ to D Reference regulation for air water heat pump: EUROPEAN REGULATION (EU) N. 811/2013 HEAT RECOVERY VENTILATION SITALI SF 150 S1 Energy efficiency class from A+ to G Reference regulation for heat recovery ventilation: EUROPEAN REGULATION (EU) N. 1254/2014 190 AIR WATER HEAT PUMPS WITH INTEGRATED STORAGE TANK OLIMPIA SPLENDID E 10 UI SHERPA TOWER S E SMALL XL A+++ A+ A++ A ++ A A+ B A C B D C E D F 46 dB 07 kW 08 kW 09 kW 60 dB 20 811/2013 Energy efficiency class from A+++ to D Energy efficiency class storage tank from A+ to F Reference regulation for air water heat pump with integrated storage tank: EUROPEAN REGULATION (EU) N. 811/2013 WATER HEATER HEAT PUMP XL A+ A B e D E F 53 dB dB SHERPA SHW S2 260S 1628 1355 1154 kWh/annum 2017 3xxxxx 812/2013 Energy efficiency class from A+ to F Reference regulation for water heat heat pump: EUROPEAN REGULATION (EU) N. 812/2013 BMS HEAT PUMPS FAN COIL UNITS DOUBLE DUCT AIR CONDITIONERS (UNICO) SINGLE DUCT AIR CONDITIONERS (PORTABLE) UNICO PRO 30 HP EVAN EER COP A+++ A+++ A++ A++ A+ A+ A+ A A A B B C C D D 2,6kW 1,8 kW 3,1 EER 3,4COP 8 kWh/60min* 0,5 kWh/60min* DOLCECLIMA AIR PRO 14 HP WIFI EER COP A+++ A+++ A++ A++ A+ A+ A+ A AA B B C C D D 3,5 kW 2,6 EER 1,4 kWh/60min* 2,9 kW 2,8 COP 1,1 kWh/60min* 57 dB ENERGIA · · · ENERGIJA · ENERGY · ENERGIE · ENERGI * · perc · 626/2011 Energy efficiency class from A+++ to D 64dB ENERGIA · · · ENERGIJA · ENERGY · ENERGIE · ENERGI * · perc · 626/2011 Energy efficiency class from A+++ to D Double duct, single duct, fixed and wall spilt air conditioner Reference Regulation: EUROPEAN REGULATION (EU) N. 626/2011 MONOSPLIT AIR CONDITIONER MULTISPLIT AIR CONDITIONER HRV UNICO MONO AND MULTISPLIT OS- EEN 09 EN 09 SEER SCOP A+++ A++ A+++ A+++ A++ A+++ A++ A+ A+ A A A B B C C D D kW 6 SEER 8 kWh/annum 07 kW 4 SCOP 6 0 kWh/annum 630 744 0 5 1891 54dB F G 58dB ENERGIA · · · ENERGIJA · ENERGY · ENERGIE 626/2011 Energy efficiency class from A+++ to D OS-CANMH14EI + OSSENEH09EI + OSSENEH09EI SEER A++++ SCOP A+++ A++ A+ A+ A B C D kW 4,1 SEER 5,6 kWh/annum 258 A+++ A++ A++ A+ A A B C D kW 4,1 3,7 X SCOP 4,6 3,8 X kWh/annum 1248 1400 X 56dB 65dB ENERGIA · · · ENERGIJA · ENERGY · ENERGIE 626/2011 Energy efficiency class from A+++ to D The technical data and aesthetic combinations of the products may change. Olimpia Splendid reserves the right to modify them at any time. 191 PORTABLES DTP1241 Data Publishing: Lithos S.r.l., Data Manager: On Page® Olimpia Splendid S.p.A. Italy, Cellatica (BS) | Headquarter Italy, Gualtieri (RE) | Logistic Hub France, Paris | Sales Subsidiary Spain, Madrid | Sales Subsidiary USA, New York | Sales Subsidiary Australia, Melbourne | Sales Subsidiary China, Shanghai | Trading Subsidiary Download these product sheets, technical and installation manuals and other documents relating to catalogue references in the new download area of the Olimpiasplendid.com website. Member of: Certified company:Adobe InDesign 18.5 (Macintosh) GPL Ghostscript 9.53.3