ASCO 300 Series Transfer Switch

Introduction

This document provides essential information for the ASCO 300 Series automatic transfer switches. It covers operator instructions, product wiring data, and outline and mounting details to ensure proper installation and operation.

Product Overview

The ASCO 300 Series is designed for reliable power transfer in critical applications. It automatically switches between a primary power source and an emergency power source when the primary source fails, ensuring continuous power availability.

Technical Specifications

Detailed technical specifications, including voltage ratings, current capacity, frequency, and environmental operating conditions, are provided in this section. For a complete list of specifications, please refer to the official product data sheet.

Product Wiring Data

The wiring diagram illustrates the internal and external connections for the ASCO 300 Series transfer switch. It details the connections for power inputs (Line 1 and Line 2), the load connection, and the neutral busbar. Control wiring terminals are clearly marked for connection to the automatic transfer control module and any external signaling devices. Grounding connections are specified for safety. Note: Always consult the specific wiring diagram provided with your unit, as configurations may vary. Verify all connections before energizing the equipment.

Outline and Mounting Data

This section provides dimensional drawings and mounting instructions. Recommended mounting locations, clearance requirements for ventilation and access, and hardware specifications are detailed. The transfer switch should be mounted vertically on a stable, non-combustible surface. Ensure adequate space around the unit for maintenance and heat dissipation.

Mounting Considerations:

  • Clearance: Maintain a minimum of 6 inches (150 mm) above and below, and 4 inches (100 mm) on the sides for proper ventilation and access.
  • Environment: Install in a clean, dry location, free from excessive dust, moisture, and corrosive fumes.
  • Fasteners: Use appropriately sized and rated mounting hardware (e.g., M6 or 1/4-inch screws) suitable for the mounting surface.

Operator's Manual

The ASCO 300 Series is designed for automatic operation. The control module continuously monitors the primary power source. Upon detecting a failure or unacceptable voltage/frequency deviation, it initiates the transfer to the emergency source. When the primary source is restored and stable, the switch will re-transfer the load back and then signal the emergency generator to shut down.

Key Operational Features:

  • Automatic Source Monitoring and Transfer
  • Adjustable Time Delays (e.g., Engine Start Delay, Retransfer Delay, Disconnect Delay)
  • Manual Operation Mode for testing and maintenance
  • Status Indicators for power sources and load connection
  • Diagnostic capabilities via the control module interface

PDF preview unavailable. Download the PDF instead.

713209 Acrobat Distiller 4.0 for Windows

Related Documents

PreviewASCO 300 Series Automatic Transfer Switch: Outline, Mounting, and Wiring Data
Comprehensive technical data for the ASCO 300 Series automatic transfer switch, covering outline dimensions, mounting instructions, and product wiring diagrams. Essential information for installation and operation.
PreviewASCO 300 Series Automatic Transfer Switch Operator's Manual
Operator's manual for the ASCO 300 Series Automatic Transfer Switch (ATS). Provides essential information on installation, operation, safety, wiring data, and mounting for emergency and standby power systems.
PreviewASCO Series 300 Automatic Transfer Switch: Outline and Mounting Dimensions (225-400 Amps)
Comprehensive technical document detailing the outline and mounting dimensions for ASCO Series 300 Automatic Transfer Switches, rated from 225 to 400 Amperes. Includes general notes, terminal specifications, and weight data for open-type, 2-pole, 3-pole, and 4-pole configurations.
PreviewASCO 300 Series 1600-2000 Ampere Transfer Switches: Composite Outline
Technical outline and specifications for ASCO 300 Series automatic transfer switches, covering 1600 to 2000 ampere ratings. Includes general and cabling notes, and dimensional views.
PreviewASCO 300 Series Transfer Switches (E3ATS/E3NTS) 260 & 400 Amperes Outline
Outline drawing and dimensional data for ASCO 300 Series E3ATS/E3NTS automatic transfer switches, rated for 260 and 400 amperes, open type. Includes general notes, cabling notes, and mounting dimensions.
PreviewASCO Series 300 Automatic Transfer Switch Wiring Diagrams and Technical Data
Comprehensive technical document detailing wiring diagrams, control schematics, physical layout, and operator controls for ASCO Series 300 Automatic Transfer Switches (ATS) with Group 1 Controls, available in 600, 800, 1000, and 1200 Ampere ratings. Includes wire run lists and accessory information.
PreviewASCO 5150 Connectivity Module Installation Manual | ASCO 5100 Series
This installation manual details the ASCO 5150 Connectivity Module, a device for integrating ASCO Automatic Transfer Switches (ATS), Power Managers, and Digital Power Meters into Ethernet networks. It covers installation, configuration, and troubleshooting for seamless monitoring and control of power systems.
PreviewASCO Series 300 Automatic Transfer Switch Wiring and Technical Data
Comprehensive technical document detailing wiring diagrams, control features, and physical layout for ASCO Series 300 Automatic Transfer Switches (ATS) rated 600-1200 Amps with Group 1 Controls.