Ubiquiti Inc. UX7 Digital Transmission Radio SWX-UX7 SWXUX7 ux7
Maximum Permissible Exposure FCC Part 2 Sections §2.1091 and §2.1093 Test Requirement(s): §15.407(f): U-NII devices are subject to the radio frequency radiation exposure requirements specified in §1.1307(b), §2.1091 and §2.1093 of this chapter, as appropriate. All equipment shall be considered to operate in a "general population/uncontrolled" environment. RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. MPE Limit: EUT's operating frequencies @ WiFi 2412 2462 MHz; UNII-1 5180 5240 MHz; UNII-2a 5260 5320 MHZ; UNII-2c 5500 5720 MHz; UNII-3 5745 5825 MHz; UNII-5 5955 6415; UNII-6 6435 6515; UNII-7 6535 6885; UNII-8 6895 7115; Limit for Uncontrolled exposure: 1 mW/cm2 or 10 W/m2 Equation from page 18 of OET 65, Edition 97-01 S = PG / 4R2 or R = (PG / 4S) Test Results: where, S = Power Density (mW/cm2) P = Power Input to antenna (mW) G = Antenna Gain (numeric value) R = Distance (cm) Frequency (MHz) 2442* 2462* 5210* 5320 5775 6265* Con. Pwr. (dBm) 6.12 27.37 27.42 22.97 26.37 22.73 Con. Pwr. (mW) 4.09 545.76 552.08 198.15 433.51 187.50 Ant. Gain (dBi) 0 4 7 7 7 6 FCC Pwr. Ant. Gain Density numeric (mW/cm2) 1.00 0.00 2.51 0.27 5.01 0.55 5.01 0.20 5.01 0.43 3.98 0.15 Limit (mW/cm2) 1.0 1.0 1.0 1.0 1.0 1.0 Margin -1.00 -0.73 -0.45 -0.80 -0.57 -0.85 Distance (cm) 20 20 20 20 20 20 Result Pass Pass Pass Pass Pass Pass *Simultaneous Transmission (Worse case): 0.97 1.0 -0.03 20 Pass The safe distance for SWX-UX7 where Power Density is less than the MPE Limit listed above was found to be 20 cm. This device does not perform power tune-ups, therefore the maximum power is used for this analysis.Microsoft Word 2016 Microsoft Word 2016