Datasheet 1292855 Mean Well RCP-2000-12 AC/DC PSU module ( enclosure) 100 A 1200 W 12 V DC

Mean Well RCP-2000-12 AC/DC PSU module ( enclosure) 100 A 1200 W 12 V DC Mean Well RCP-2000-12 4021087006187

Datasheet 1292856 Mean Well RCP-2000-24 AC/DC PSU module ( enclosure) 80 A 2000 W 24 V DC

Mean Well RCP-2000-24 AC/DC PSU module ( enclosure) 80 A 2000 W 24 V DC Mean Well RCP-2000-24 4021087006170

datasheet-1292856-mean-well-rcp-2000-24-acdc-psu-module-enclosure-80-a-2000-w-24-v-dc
2000W Front End Power Supply

RCP-2000 series

 Features :
Universal AC input / Full range Built-in 5V/0.3A, 12V/0.8A auxiliary power Built-in active PFC function, PF>0.98 High efficiency up to 92% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature 3
High Power density 21.4W/inch
Forced air cooling by built-in DC fan with fan speed control Low profile:1U height Remote control for single unit Built-in remote sense function Output voltage trimming function Hot-swap operation PMBus serial communication AC OK, DC OK signal, fan fail, OTP alarm signal Internal OR-ing FET 3 years warranty
 Description :
The RCP-2000 series are state of the art AC/DC frond-end rectifiers with 1U compact size and 21.4 W/in3 of high power density. They can
provide up to 2000W per unit for the applications of servers, information technology equipment, networking, telecommunications, and wide
range of industrial applications using distributed power architecture. Equipped with hot-swap function and PMBus communication protocol,
RCP-2000 can be assembled in 1U 19 rack and controlled/monitored by external device such as monitoring unit (RCP-CMU-1) or PC.

SPECIFICATION - Single Unit

MODEL

RCP-2000-12

RCP-2000-24

RCP-2000-48

DC VOLTAGE

12V

24V

48V

RATED CURRENT

100A

CURRENT RANGE

0 ~ 100A

RATED POWER

1200W

RIPPLE & NOISE (max.) Note.2 150mVp-p

80A 0 ~ 80A 1920W 200mVp-p

42A 0 ~ 42A 2016W 300mVp-p

OUTPUT

VOLTAGE ADJ. RANGE

10.5 ~ 14V

VOLTAGE TOLERANCE Note.3 ±2.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±1.0%

21 ~ 28V ±1.0% ±0.5% ±0.5%

42 ~ 56V ±1.0% ±0.5% ±0.5%

SETUP, RISE TIME HOLD UP TIME (Typ.)

1500ms, 60ms/230VAC at full load 16ms/230VAC at 75% load 10ms/230VAC at full load

VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC

INPUT

FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.)

47 ~ 63Hz 0.98/230VAC at full load 86% 13A/115VAC 7A/230VAC COLD START 50A

90.5% 16A/115VAC

10A/230VAC

92% 16A/115VAC

10A/230VAC

LEAKAGE CURRENT

<1.1mA / 230VAC

OVERLOAD

105 ~ 125% rated output power Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover

PROTECTION OVER VOLTAGE

14.7 ~ 17.5V

29.5 ~ 35V

Protection type : Shut down o/p voltage, re-power on to recover

57.6 ~ 67.2V

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

AUXILIARY POWER

5V @ 0.3A, 12V @ 0.8A

REMOTE ON/OFF CONTROL By electrical signal or dry contact ON:short OFF:open

REMOTE SENSE

Compensate voltage drop on the load wiring up to 0.5V

DC OK SIGNAL FUNCTION
AC OK SIGNAL

The isolated TTL signal out, refer to function manual The isolated TTL signal out, refer to function manual

OUTPUT VOLTAGE TRIM Adjustment of output voltage, possible between 90 ~ 110% of rated output

OVER TEMP WARNING

Logic " High" for over temperature warning, refer to function manual, isolated signal

FAN FAIL SIGNAL

The isolated TTL signal out, refer to function manual

WORKING TEMP.

-40 ~ +70 (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/ (0 ~ 50)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

File Name:RCP-2000-SPEC 2013-11-01

2000W Front End Power Supply

RCP-2000 series

MODEL

RCP-2000-12

RCP-2000-24

RCP-2000-48

SAFETY STANDARDS

SAFETY & WITHSTAND VOLTAGE

EMC

ISOLATION RESISTANCE

(Note 4) EMC EMISSION

UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55022 (CISPR22) Conduction Class B, Radiation Class A ; EN61000-3-2,-3

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A

MTBF

60.1K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION PACKING

295*127*41mm (L*W*H) 2Kg;6pcs/13Kg/1.04CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. Output of all the RCP-2000 modules are connected in parallel in the rack. 7. Under parallel operation of more than one rack connecting together, ripple of the output voltage may be higher than the SPEC at light load condition.
It will go back to normal ripple level once the output load is more than 10%.

Mechanical Specification (Single Unit)

Case No. 974A Unit:mm

41 CN501

2 95 SVR1

24
Air flow d ir e c t io n

13579

33

11 14 17 20 23 26 29 12 15 18 21 24 27 30 13 16 19 22 25 28 31

2 4 6 8 10

32 34

Input / Output Connector Pin No. Assignment(CN501) : Postronic PCIM34W13M400A1

Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment

1,2,3,4

+V

12

DA

17

ON/OFF

22

NC

5,6,7,8

-V

13

DB

18

A1

23

SDA

9

-V(signal) 14

+S

19

A2

24

SCL

10 +V(signal) 15

-S

20

A3

25

AC-OK

11

PV

16

A0

21

A4

26

DC-OK

Pin No. 27 28 29 30 31

Assignment T-ALARM FAN-FAIL +5V-AUX + 12 V- A UX GND-AUX

Pin No. 32 33 34

Assignment Mating Housing

FG

AC/L AC/N

Postronic PCIM34W13F400A1

File Name:RCP-2000-SPEC 2013-11-01

2000W Front End Power Supply

RCP-2000 series

Block Diagram

I/P

EM I

F I LT ER

AC TIVE INR USH
CURRENT LIMITING

RECTIFIERS &
PFC

PO W E R SW IT CHIN G

PFC CONTROL
DETECTION CIR CUIT

PW M CON TROL
MCU
O.T.P. FAN
AU X PO W E R

RECTIFIERS &
FILTER
O.V.P.
DETEC TION CIR CUIT
MCU
RECTIFIERS &
FILTER

PFC fosc : 110KHz PWM fosc : 90KHz

ORI NG FET
ORING FET CONTROL
TR A N S C E IV E R S

+S +V -V -S
PV DA/DB

DATA IS O LAT ION
1 2V /0. 8A AU X POWER 5V/0 .3A

T- Ala rm DC-O K AC-OK FAN FAIL SD A /S CL
PM BUS
ON/O FF

Function Description of CN501

Pin No. Function Description

1,2,3,4

+V Positive output voltage

5,6,7,8

-V

Negative output voltage.

9

-V

-V Signal

10

+V +V Signal

11

PV Connection for output voltage trimming. The voltage can be trimmed within its defined range. (Note.1)

12,13

DA,DB Differential digital signal for parallel control. (Note.1)

Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be

14

+S

twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.

Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be

15

-S

twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.

16,18,19, A0,A1,A2,

PMBus interface address lines. (Note.1)

20,21

A3,A4

The unit can turn the output on and off by electrical signal or dry contact between ON/OFF and +5V-AUX. (Note.2)

17

ON/OFF

Short (4.5 ~ 5.5V) : Power ON ; Open (0 ~ 0.5V) : Power OFF ; The maximum input voltage is 5.5V.

22

NC Not use.

23

SDA Serial Data used in the PMBus interface. (Note.2)

24

SCL Serial Clock used in the PMBus interface. (Note.2)

Low (0 ~ 0.5V) : When the input voltage is 87Vrms.

25

AC-OK

High (4.5 ~ 5.5V) : When the input voltage in 75Vrms . The maximum sourcing current is 10mA and only for output. (Note.2)

High (4.5 ~ 5.5V) : When the Vout 80%±5%.

26

DC-OK

Low (0 ~ 0.5V) : When Vout 80%±5%. The maximum sourcing current is 10mA and only for output. (Note.2)

High (4.5 ~ 5.5V) : When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm.

27

T-ALARM Low (0 ~ 0.5V) : When the internal temperature (TSW1 or TSW2 short) under the limit temperature. The maximum sourcing

current is 10mA and only for output(Note.2)

High (4.5 ~ 5.5V) : When the internal fan fail.

28

FA N - FA IL

Low (0 ~ 0.5V) : When the internal fan is normal. The maximum sourcing current is 10mA and only for output(Note.2)

Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX (pin 31). The maximum load current is 0.3A. This output has the

29

+5V-AUX

built-in "Oring diodes" and is not controlled by the remote ON/OFF control.

Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin 31). The maximum load current is 0.8A. This output has

30

+12V-AUX

the built-in "Oring diodes" and is not controlled by the remote ON/OFF control.

31

GND-AUX Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V).

32

FG AC Ground connection.

33

AC/L AC Line connection.

34

AC/N AC Neutral connection.

Note1: Non-isolated signal, referenced to the output terminals (-V). Note2: Isolated signal, referenced to GND-AUX.

File Name:RCP-2000-SPEC 2013-11-01

2000W Front End Power Supply

RCP-2000 series

Derating Curve

Static Characteristics

100
80 230VAC Input only
60 50 40
20

100

90

80

75

12V

70

65

24V,48V

50 40

-40

-25 -10 0

15 30 50 60 70 (HORIZONTAL)

90

100

115

180

264

AMBIENT TEMPERATURE ()

INPUT VOLTAGE (VAC) 60Hz

EFFICIENCY vs LOAD (48V Model)
94 92 90 88 86 84 82
10 20 30 40 50 60 70 80 90 100
LOAD

DERATING LOAD(%) VS INPUT VOLTAGE

INPUT / VOLTAGE

MODEL

>180VAC

RCP-2000-12

100%

115VAC 95%

RCP-2000-24

100%

80%

RCP-2000-48

100%

80%

100VAC 90% 75% 75%

90VAC 80% 65% 65%

Function Manual
1. Remote ON/OFF Control The PSU can be turned ON/OFF together or separately by using the "Remote ON/OFF" function.

Between ON/OFF and +5V-AUX Output

17

ON/OFF RC P- 2000

SW Open

OFF

SW

29 +5 V-AUX

SW Short

ON

2. Voltage Drop Compensation 2.1 Remote Sense The remote sense compensates voltage drop on the load wiring up to 0.5V.

+V

+V

14

+S

RC P- 2000

15

-S

-V

-V

LOAD

Sense lines sh ould be t wisted in pairs

File Name:RCP-2000-SPEC 2013-11-01

2000W Front End Power Supply

RCP-2000 series

2.2 Local Sense Notice : The +S,-S have to be connected to the +V,-V terminals locally in order to get the correct output voltage if the remote sensing is not used.

RCP-2 000

+V 14
+S
-V 15
-S

3. Output Voltage Trimming (1)Output voltage can be trimmed between 90~110% of its rated value by the following method. (2)+S & +V, -S & -V also need to be connected on CN501.

RC P- 2000

14 +S
+V
-V 15
-S 11
PV 9
-V Signal

L OA D 0~5V

Add on 0~5V external voltage

Vout

110

100

90

80

70

60

V

0

0.5 1.5

3

4.5

5

EXTERNAL VOLTAGE (DC)

4. Front Panel Indicators & Corresponding Signal at Function Pins

Function LED

Description

* Signal PSU Output

AC-OK GREEN When input voltage87V

0 ~ 0.5V

ON

AC-NG RED When input voltage 75V DC-OK GREEN When output voltage80%±5% of Vo rated.

4.5 ~ 5.5V OFF

0 ~ 0.5V

ON

DC-NG RED When output voltage80%±5% of Vo rated.

4.5 ~ 5.5V

ON

T-OK GREEN When the internal temperature (TSW1 & TSW2 short) is within safe limit

0 ~ 0.5V

ON

T-ALARM RED When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm 4.5 ~ 5.5V OFF

*Signal between function pin and "GND-AUX".

File Name:RCP-2000-SPEC 2013-11-01


Foxit PhantomPDF Printer Version 5.0.0.0601