BLU Products, Inc. BLUC5LMX175 YHLBLUC5LMX175 YHLBLUC5LMX175 bluc5lmx175
REPORT No.SZ23040024W03 TEST REPORT APPLICANT PRODUCT NAME MODEL NAME BRAND NAME FCC ID STANDARD(S) RECEIPT DATE TEST DATE ISSUE DATE : BLU Products, Inc. : Smart Phone : C5L MAX : BLU : YHLBLUC5LMX175 : 47 CFR Part 15 Subpart C : 2023-04-03 : 2023-04-07 to 2023-05-23 : 2023-06-12 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 1 of 93 REPORT No.SZ23040024W03 DIRECTORY 1. Summary of Test Result 4 1.1. Testing Applied Standards 5 1.2. Test Equipment List 6 1.3. Measurement Uncertainty 8 1.4. Testing Laboratory 8 2. General Description 9 2.1. Information of Applicant and Manufacturer 9 2.2. Information of EUT 9 2.3. Channel List of EUT 10 2.4. Test Configuration of EUT 11 2.5. Test Conditions 11 2.6. Test Setup Layout Diagram 12 3. Test Results 15 3.1. Antenna Requirement 15 3.2. Duty Cycle of Test Signal 16 3.3. Maximum Peak and Average Conducted Output Power17 3.4. 6 dB Bandwidth 18 3.5. Conducted Spurious Emissions and Band Edge19 3.6. Power Spectral Density 20 3.7. Conducted Emission21 3.8. Restricted Frequency Bands 22 3.9. Radiated Emission23 Annex A Test Data and Result 25 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 2 of 93 Version 1.0 REPORT No.SZ23040024W03 Change History Date 2023-06-12 Reason for change First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 3 of 93 1. Summary of Test Result REPORT No.SZ23040024W03 No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A PASS No deviation 2 N/A Duty Cycle of Test Signal Apr. 08, 2023 Zhong Yanshan PASS No deviation 3 15.247(b) Maximum Peak Conducted Output Power Apr. 08, 2023 Zhong Yanshan PASS No deviation Maximum 4 15.247(b) Average Conducted Apr. 08, 2023 Zhong Yanshan PASS No deviation Output Power 5 15.247(a) Bandwidth Apr. 08, 2023 Zhong Yanshan PASS No deviation Conducted 6 15.247(d) Spurious Emission and Apr. 17, 2023 Zhong Yanshan PASS No deviation Band Edge 7 15.247(e) Power Spectral Density Apr. 17, 2023 Zhong Yanshan PASS No deviation 8 15.207 Conducted Emission Apr. 12, 2023 Fan Zehang PASS No deviation Restricted 9 15.247(d) Frequency May 22, 2023 Li Hanbin PASS No deviation Bands 10 15.209, 15.247(d) Radiated Emission Apr. 26, 2023 Li Hanbin PASS No deviation Note 1: The tests were performed according to the method of measurements prescribed in ANSIC63.10-2013 and KDB558074 D01 v05r02. Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 3: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 4 of 93 1.1. Testing Applied Standards REPORT No.SZ23040024W03 According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: 47 CFR Part 15 Subpart C Radio Frequency Devices MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 5 of 93 1.2. Test Equipment List REPORT No.SZ23040024W03 1.2.1 Conducted Test Equipments Equipment Name Serial No. Type EXA Signal Analzyer MY53470836 N9010A Power Sensor MY54180008 U2021XA Attenuator MTJ6004-20 VAT-10+ RF Cable (30MHz-26GHz) CB01 RF01 Coaxial Cable CB02 RF02 SMA Connector CN01 RF03 Manufacturer Agilent Agilent MTJ Cooperation Morlab Morlab HUBER-SUHNER Cal. Date 2023.02.27 2022.10.11 N/A N/A N/A N/A Due Date 2024.02.26 2023.10.10 N/A N/A N/A N/A 1.2.2 Conducted Emission Test Equipments Equipment Name Serial No. Type Receiver MY56400093 N9038A LISN Pulse Limiter (10dB) RF Coaxial Cable (DC-100MHz) 8127449 VTSD 9561 F-B #206 BNC NSLK 8127 VTSD 9561-F MRE04 Manufacturer KEYSIGHT Cal. Date Due Date 2023.02.09 2024.02.08 Schwarzbeck 2023.02.21 2024.02.20 Schwarzbeck 2022.07.06 2023.07.05 Qualwave 2022.07.08 2023.07.07 1.2.3 List of Software Used Description Test System Morlab EMCR V1.2 TS+ -[JS32-CE] Manufacturer MaiWei Morlab Tonscend Software Version 2.0.0.0 V1.0 V2.5.0.0 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 6 of 93 REPORT No.SZ23040024W03 1.2.4 Radiated Test Equipments Equipment Name Serial No. Receiver MY54130016 Test Antenna Bi-Log 9163-519 Test Antenna Loop 1519-022 Test Antenna Horn 01774 Test Antenna BBHA9170 Horn #773 Preamplifier (10MHz-6GHz) 46732 Preamplifier (2GHz-18GHz) 61171/61172 Preamplifier (18GHz-40GHz) DS77209 Type N9038A VULB 9163 FMZB1519 BBHA 9120D BBHA9170 S10M100L38 02 S020180L32 03 DCLNA0118- 40C-S RF Coaxial Cable (DC-18GHz) MRE001 PE330 RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-18GHz) Notch Filter Anechoic Chamber MRE002 MRE003 22290045 22290046 22120181 N/A N/A CLU18 CLU18 QA360-40-K K-0.5 QA360-40-K KF-2 QA500-18-N N-5 WRCG-24002483.5-60SS 9m*6m*6m Manufacturer Agilent Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP. Decentest Pasternack Pasternack Pasternack Qualwave Qualwave Qualwave Wainwright CRT Cal. Date 2022.07.06 2022.05.25 2022.02.11 2022.07.13 2022.07.14 2022.07.08 2022.07.08 2022.07.23 2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.05.10 Due Date 2023.07.05 2025.05.24 2025.02.10 2025.07.12 2025.07.13 2023.07.07 2023.07.07 2023.07.22 2023.07.07 2023.07.07 2023.07.07 2023.07.07 2023.07.07 2023.07.07 2023.07.07 2025.05.09 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 7 of 93 1.3. Measurement Uncertainty REPORT No.SZ23040024W03 Test Items Peak Output Power Power Spectral Density Bandwidth Conducted Spurious Emission Restricted Frequency Bands Radiated Emission Conducted Emission 1.4. Testing Laboratory Uncertainty ±2.22dB ±2.22dB ±5% ±2.77dB ±5% ±2.95dB ±2.44dB Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Laboratory Name Laboratory Address Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192 226174 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 8 of 93 2. General Description REPORT No.SZ23040024W03 2.1. Information of Applicant and Manufacturer Applicant Applicant Address Manufacturer Manufacturer Address BLU Products, Inc. 8600 NW 36th Street, Suite #200 Doral, FL 33166, USA BLU Products, Inc. 8600 NW 36th Street, Suite #200 Doral, FL 33166, USA 2.2. Information of EUT Product Name: Sample No.: Hardware Version: Software Version: Modulation Technology: Modulation Type: Operating Frequency Range: Antenna Type: Antenna Gain: Accessory Information: Smart Phone 1# A507-MB-V3.6D A507-37H_sp9832e_1h10_go2g-userdebug-native_0307_144 3 DSSS, OFDM Refer to section1.3 802.11b/g/ n (HT20): 2412MHz2472MHz PIFA Antenna -0.62dBi Battery Brand Name: BLU Model No.: C775444200L Serial No.: N/A Capacity: 2000mAh Rated Voltage: 3.8V Charge Limit: 4.35V Manufacturer: Shenzhen Aerospace Electronic Co.,Ltd. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 9 of 93 REPORT No.SZ23040024W03 Adaptor Brand Name: BLU Model No.: US-JY-1000 Accessory Information: Serial No.: Rated Output: N/A 5V 1000mA Rated Input: 100-240V 50/60Hz, 0.3A Manufacturer: Dongguan Jieyuan Electronic Technology Co., LTD Note 1: We use the dedicated software to control the EUT continuous transmission. Note 2: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. 2.3. Channel List of EUT Test Mode Channel Frequency (MHz) 1 2412 2 2417 3 2422 802.11b/g/n (HT20) 4 2427 5 2432 6 2437 7 2442 Note 1: The black bold channels were selected for test. Channel 8 9 10 11 12 13 Frequency (MHz) 2447 2452 2457 2462 2467 2472 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 10 of 93 2.4. Test Configuration of EUT REPORT No.SZ23040024W03 2.4.1.Modulation Type and Data Rate of EUT Modulation technology Modulation Type Data Rate (Mbps) Note1 DBPSK 1 DSSS (802.11b) DQPSK 2 CCK 5.5/ 11 BPSK 6 / 9 OFDM (802.11g) QPSK 16QAM 12 / 18 24 / 36 64QAM 48 / 54 BPSK 6.5 OFDM QPSK 13/19.5 (802.11n (HT20)) 16QAM 26/39 64QAM 52/58.5/65 Note1: The worst-case mode (bold face) in all data rates has been determined during the pre-scan, only the test data of the worst-case were recorded in this report. Note2: The RF signal transmission of EUT is controlled by the build-in engineering mode which is provided by the manufacturer. The recorded power setting value is the maximum that the engineering mode has configuration during testing. 2.5. Test Conditions Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa) 15-35 30-60 86-106 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 11 of 93 2.6. Test Setup Layout Diagram 2.6.1.Conducted Measurement Power item REPORT No.SZ23040024W03 Other items 2.6.2.Conducted Emission Measurement MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 12 of 93 2.6.3.Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz REPORT No.SZ23040024W03 2) For radiated emissions from 30MHz to1GHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 13 of 93 3) For radiated emissions above 1GHz REPORT No.SZ23040024W03 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 14 of 93 3. Test Results REPORT No.SZ23040024W03 3.1. Antenna Requirement 3.1.1.Requirement According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. 3.1.2.Test Result Inside of the EUT has a PIFA antenna coupled with the metal shrapnel. Please refer to the EUT internal photos. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 15 of 93 3.2. Duty Cycle of Test Signal REPORT No.SZ23040024W03 3.2.1.Requirement Preferably, all measurements of maximum conducted (average) output power will be performed with the EUT transmitting continuously (i.e., with a duty cycle of greater than or equal to 98%).When continuous operation cannot be realized, then the use of sweep triggering/signal gating techniques can be used to ensure that measurements are made only during transmissions at the maximum power control level. Such sweep triggering/signal gating techniques will require knowledge of the minimum transmission duration(T) over which the transmitter is on and is transmitting at its maximum power control level for the tested mode of operation. Sweep triggering/signal gating techniques can then be used if the measurement/sweep time of the analyzer can be set such that it does not exceed T at any time that data are being acquired (i.e.,no transmitter OFF-time is to be considered). When continuous transmission cannot be achieved and sweep triggering/signal gating cannot be implemented, alternative procedures are provided that can be used to measure the average power; however, they will require an additional measurement of the transmitter duty cycle (D). Within this sub clause, the duty cycle refers to the fraction of time over which the transmitter is ON and is transmitting at its maximum power control level. The duty cycle is considered to be constant if variations are less than ±2%; otherwise, the duty cycle is considered to be non constant. 3.2.2.Test Result Refer to Annex A.1 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 16 of 93 REPORT No.SZ23040024W03 3.3. Maximum Peak and Average Conducted Output Power 3.3.1.Requirement According to FCC section 15.247(b)(3), For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: The maximum conducted output power of the intentional radiator shall not exceed 1 Watt. 3.3.2.Test Procedures The EUT (Equipment under the test) which is coupled to the USB Wideband Power Sensor; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. 3.3.3.Test Setup Layout Refer to chapter 2.6.1 in this report. 3.3.4.Test Result Refer to Annex A.2 and A.3 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 17 of 93 3.4. 6 dB Bandwidth REPORT No.SZ23040024W03 3.4.1.Requirement According to FCC section 15.247(a) (2), systems using digital modulation techniques may operate in the 902 - 928 MHz, 2400 - 2483.5 MHz, and 5725 - 5850 MHz bands. The minimum 6dB bandwidth shall be at least 500 kHz. 3.4.1.Test Procedures KDB 558074 Section 8.2 was used in order to prove compliance. 3.4.2.Test Setup Layout Refer to chapter 2.6.1 in this report. 3.4.3.Test Result Refer to Annex A.4 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 18 of 93 REPORT No.SZ23040024W03 3.5. Conducted Spurious Emissions and Band Edge 3.5.1.Requirement According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. 3.5.2.Test Procedures KDB 558074 Section 8.5 and 8.7 was used in order to prove compliance. 3.5.3.Test Setup Layout Refer to chapter 2.6.1 in this report. 3.5.4.Test Result Refer to Annex A.5 and A.6 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 19 of 93 3.6. Power Spectral Density REPORT No.SZ23040024W03 3.6.1.Requirement For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral density shall be determined in accordance with the provisions of paragraph (b) of this section. The same method of determining the conducted output power shall be used to determine the power spectral density. 3.6.2.Test Procedures The measured power spectral density was calculated by the reading of the spectrum analyzer and calibration. Following is the test procedure for PSD test: a) Set analyzer center frequency to channel center frequency b) Set span to1.5 times DTS c) Set RBW to 30kHz d) Set VBW to 100kHz e) Detector = peak f) Sweep time = auto couple g) Trace mode = max hold h) Allow trace to fully stabilize i) Use the peak marker function to determine the maximum amplitude level and recorded as PD j) Use below formula to calculate the Conducted PSD value that at specified RBW: Conducted PSD=PD-10lg(30k/3k) 3.6.3.Test Setup Layout Refer to chapter 2.6.1 in this report. 3.6.4.Test Result Refer to Annex A.7 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 20 of 93 3.7. Conducted Emission REPORT No.SZ23040024W03 3.7.1.Requirement According to FCC section 15.207, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency Range (MHz) Conducted Limit (dBµV) Quai-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 Note: (a) The lower limit shall apply at the band edges. (b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. 3.7.2.Test Procedures The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013. 3.7.3.Test Setup Layout Refer to chapter 2.6.2 in this report. 3.7.4.Test Result Refer to Annex A.8 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 21 of 93 3.8. Restricted Frequency Bands REPORT No.SZ23040024W03 3.8.1.Requirement According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a). 3.8.2.Test Procedures The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f 1GHz, 100 kHz for f < 1GHz VBW = 3 MHz Sweep = auto Detector function = peak/average Trace = max hold Allow the trace to stabilize 3.8.3.Test Setup Layout Refer to chapter 2.6.3 in this report. 3.8.4.Test Result Refer to Annex A.9 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 22 of 93 3.9. Radiated Emission REPORT No.SZ23040024W03 3.9.1.Requirement According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) Field Strength (µV/m) Measurement Distance (m) 0.009 - 0.490 2400/F(kHz) 300 0.490 - 1.705 24000/F(kHz) 30 1.705 - 30.0 30 30 30 - 88 100 3 88 - 216 150 3 216 - 960 200 3 Above 960 500 3 Note1: For above 1000MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. Note2:For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and 74dBuV/m@3m (PK).In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), also should comply with the radiated emission limits specified in Section 15.209(a)(above table). MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 23 of 93 3.9.2.Test Procedures REPORT No.SZ23040024W03 The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode. For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector. For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak. For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements. The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. 3.9.3.Test Setup Layout Refer to chapter 2.6.3 in this report. 3.9.4.Test Result Refer to Annex A.10 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 24 of 93 REPORT No.SZ23040024W03 Annex A Test Data and Result A.1. Duty Cycle of Test Signal Condition NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT Mode b b b g g g n20 n20 n20 Frequency (MHz) 2412 2442 2472 2412 2442 2472 2412 2442 2472 Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Duty Cycle (%) 99.71 99.71 99.71 98.48 98.39 98.02 97.87 98.27 98.27 Correction Factor (dB) 0.01 0.01 0.01 0.07 0.07 0.09 0.09 0.08 0.08 1/T (kHz) 0.08 0.08 0.08 0.48 0.48 0.48 0.52 0.52 0.52 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 25 of 93 REPORT No.SZ23040024W03 Test Graphs Duty Cycle NVNT b 2412MHz Ant1 Duty Cycle NVNT b 2442MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 26 of 93 REPORT No.SZ23040024W03 Duty Cycle NVNT b 2472MHz Ant1 Duty Cycle NVNT g 2412MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 27 of 93 REPORT No.SZ23040024W03 Duty Cycle NVNT g 2442MHz Ant1 Duty Cycle NVNT g 2472MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 28 of 93 REPORT No.SZ23040024W03 Duty Cycle NVNT n20 2412MHz Ant1 Duty Cycle NVNT n20 2442MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 29 of 93 REPORT No.SZ23040024W03 Duty Cycle NVNT n20 2472MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 30 of 93 REPORT No.SZ23040024W03 A.2. Maximum Peak Conducted Output Power Frequency Conducted Condition Mode Antenna (MHz) Power (dBm) NVNT b NVNT b NVNT b NVNT g NVNT g NVNT g NVNT n20 NVNT n20 NVNT n20 2412 2442 2472 2412 2442 2472 2412 2442 2472 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 18.13 18.26 18.1 20.49 20.31 18.50 19.20 18.55 17.56 Duty Factor (dB) 0 0 0 0 0 0 0 0 0 Total Power (dBm) 18.13 18.26 18.1 20.49 20.31 18.50 19.20 18.55 17.56 Limit Verdict (dBm) 30 Pass 30 Pass 30 Pass 30 Pass 30 Pass 30 Pass 30 Pass 30 Pass 30 Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 31 of 93 REPORT No.SZ23040024W03 Test Graphs Peak Power NVNT b 2412MHz Ant1 Peak Power NVNT b 2442MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 32 of 93 REPORT No.SZ23040024W03 Peak Power NVNT b 2472MHz Ant1 Peak Power NVNT g 2412MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 33 of 93 REPORT No.SZ23040024W03 Peak Power NVNT g 2442MHz Ant1 Peak Power NVNT g 2472MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 34 of 93 REPORT No.SZ23040024W03 Peak Power NVNT n20 2412MHz Ant1 Peak Power NVNT n20 2442MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 35 of 93 REPORT No.SZ23040024W03 Peak Power NVNT n20 2472MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 36 of 93 REPORT No.SZ23040024W03 A.3. Maximum Average Conducted Output Power Frequency Conducted Condition Mode Antenna (MHz) Power (dBm) NVNT b NVNT b NVNT b NVNT g NVNT g NVNT g NVNT n20 NVNT n20 NVNT n20 2412 2442 2472 2412 2442 2472 2412 2442 2472 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 15.61 15.20 15.51 13.51 13.22 11.18 11.57 11.00 10.12 Duty Factor (dB) 0.01 0.01 0.01 0.07 0.07 0.09 0.09 0.08 0.08 Total Power (dBm) 15.62 15.21 15.52 13.58 13.29 11.27 11.66 11.08 10.2 Limit Verdict (dBm) 30 Pass 30 Pass 30 Pass 30 Pass 30 Pass 30 Pass 30 Pass 30 Pass 30 Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 37 of 93 REPORT No.SZ23040024W03 Test Graphs Average Power NVNT b 2412MHz Ant1 Average Power NVNT b 2442MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 38 of 93 REPORT No.SZ23040024W03 Average Power NVNT b 2472MHz Ant1 Average Power NVNT g 2412MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 39 of 93 REPORT No.SZ23040024W03 Average Power NVNT g 2442MHz Ant1 Average Power NVNT g 2472MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 40 of 93 REPORT No.SZ23040024W03 Average Power NVNT n20 2412MHz Ant1 Average Power NVNT n20 2442MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 41 of 93 REPORT No.SZ23040024W03 Average Power NVNT n20 2472MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 42 of 93 REPORT No.SZ23040024W03 A.4. 6 dB Bandwidth Condition Mode NVNT b NVNT b NVNT b NVNT g NVNT g NVNT g NVNT n20 NVNT n20 NVNT n20 Frequency (MHz) 2412 2442 2472 2412 2442 2472 2412 2442 2472 Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 -6 dB Bandwidth (MHz) 8.569 9.095 8.611 14.415 16.369 16.366 17.298 17.582 17.283 Limit -6 dB Bandwidth (MHz) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 43 of 93 REPORT No.SZ23040024W03 Test Graphs -6dB Bandwidth NVNT b 2412MHz Ant1 -6dB Bandwidth NVNT b 2442MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 44 of 93 REPORT No.SZ23040024W03 -6dB Bandwidth NVNT b 2472MHz Ant1 -6dB Bandwidth NVNT g 2412MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 45 of 93 REPORT No.SZ23040024W03 -6dB Bandwidth NVNT g 2442MHz Ant1 -6dB Bandwidth NVNT g 2472MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 46 of 93 REPORT No.SZ23040024W03 -6dB Bandwidth NVNT n20 2412MHz Ant1 -6dB Bandwidth NVNT n20 2442MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 47 of 93 REPORT No.SZ23040024W03 -6dB Bandwidth NVNT n20 2472MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 48 of 93 REPORT No.SZ23040024W03 A.5. Conducted Spurious Emissions Condition NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT Mode b b b g g g n20 n20 n20 Frequency (MHz) 2412 2442 2472 2412 2442 2472 2412 2442 2472 Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Max Value (dBc) -35.48 -29.86 -35.35 -29.01 -26.98 -29.55 -27.95 -24.32 -28.06 Limit (dBc) -20 -20 -20 -20 -20 -20 -20 -20 -20 Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 49 of 93 REPORT No.SZ23040024W03 Test Graphs Tx. Spurious NVNT b 2412MHz Ant1 Ref Tx. Spurious NVNT b 2412MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 50 of 93 REPORT No.SZ23040024W03 Tx. Spurious NVNT b 2442MHz Ant1 Ref Tx. Spurious NVNT b 2442MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 51 of 93 REPORT No.SZ23040024W03 Tx. Spurious NVNT b 2472MHz Ant1 Ref Tx. Spurious NVNT b 2472MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 52 of 93 REPORT No.SZ23040024W03 Tx. Spurious NVNT g 2412MHz Ant1 Ref Tx. Spurious NVNT g 2412MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 53 of 93 REPORT No.SZ23040024W03 Tx. Spurious NVNT g 2442MHz Ant1 Ref Tx. Spurious NVNT g 2442MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 54 of 93 REPORT No.SZ23040024W03 Tx. Spurious NVNT g 2472MHz Ant1 Ref Tx. Spurious NVNT g 2472MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 55 of 93 REPORT No.SZ23040024W03 Tx. Spurious NVNT n20 2412MHz Ant1 Ref Tx. Spurious NVNT n20 2412MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 56 of 93 REPORT No.SZ23040024W03 Tx. Spurious NVNT n20 2442MHz Ant1 Ref Tx. Spurious NVNT n20 2442MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 57 of 93 REPORT No.SZ23040024W03 Tx. Spurious NVNT n20 2472MHz Ant1 Ref Tx. Spurious NVNT n20 2472MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 58 of 93 REPORT No.SZ23040024W03 A.6. Band Edge Condition NVNT NVNT NVNT NVNT NVNT NVNT Mode b b g g n20 n20 Frequency (MHz) 2412 2472 2412 2472 2412 2472 Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Max Value (dBc) -50.52 -38.29 -36.60 -29.42 -35.27 -31.41 Limit (dBc) -20 -20 -20 -20 -20 -20 Verdict Pass Pass Pass Pass Pass Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 59 of 93 REPORT No.SZ23040024W03 Test Graphs Band Edge NVNT b 2412MHz Ant1 Ref Band Edge NVNT b 2412MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 60 of 93 REPORT No.SZ23040024W03 Band Edge NVNT b 2472MHz Ant1 Ref Band Edge NVNT b 2472MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 61 of 93 REPORT No.SZ23040024W03 Band Edge NVNT g 2412MHz Ant1 Ref Band Edge NVNT g 2412MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 62 of 93 REPORT No.SZ23040024W03 Band Edge NVNT g 2472MHz Ant1 Ref Band Edge NVNT g 2472MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 63 of 93 REPORT No.SZ23040024W03 Band Edge NVNT n20 2412MHz Ant1 Ref Band Edge NVNT n20 2412MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 64 of 93 REPORT No.SZ23040024W03 Band Edge NVNT n20 2472MHz Ant1 Ref Band Edge NVNT n20 2472MHz Ant1 Emission MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 65 of 93 REPORT No.SZ23040024W03 A.7. Power Spectral Density Condition NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT Mode b b b g g g n20 n20 n20 Frequency (MHz) 2412 2442 2472 2412 2442 2472 2412 2442 2472 Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Conducted PSD (dBm/3kHz) -7.03 -9.27 -4.29 -14.74 -16.78 -11.88 -14.3 -19.21 -14.05 Duty Factor (dB) 0 0 0 0 0 0 0 0 0 Total PSD (dBm/3kHz) -7.03 -9.27 -4.29 -14.74 -16.78 -11.88 -14.3 -19.21 -14.05 Limit (dBm/3kHz) 8 8 8 8 8 8 8 8 8 Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 66 of 93 REPORT No.SZ23040024W03 Test Graphs PSD NVNT b 2412MHz Ant1 PSD NVNT b 2442MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 67 of 93 REPORT No.SZ23040024W03 PSD NVNT b 2472MHz Ant1 PSD NVNT g 2412MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 68 of 93 REPORT No.SZ23040024W03 PSD NVNT g 2442MHz Ant1 PSD NVNT g 2472MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 69 of 93 REPORT No.SZ23040024W03 PSD NVNT n20 2412MHz Ant1 PSD NVNT n20 2442MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 70 of 93 REPORT No.SZ23040024W03 PSD NVNT n20 2472MHz Ant1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 71 of 93 REPORT No.SZ23040024W03 A.8. Conducted Emission The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT + Adapter + USB Cable + Earphone +WIFI TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 72 of 93 B. Test Plot: REPORT No.SZ23040024W03 (L Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1635 39.31 27.87 2 0.1941 37.99 28.05 3 0.4376 31.16 25.17 4 0.5482 39.43 31.86 5 0.5739 42.11 33.69 6 1.3080 32.72 25.68 Limit (dBµV) Quai-peak 65.28 63.86 57.11 56.00 56.00 56.00 Average 55.28 53.86 47.11 46.00 46.00 46.00 Power-line Verdict PASS PASS Line PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 73 of 93 REPORT No.SZ23040024W03 (N Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1582 41.70 30.74 2 0.5480 48.90 38.32 3 0.5832 49.38 39.24 4 0.6086 43.71 33.08 5 0.7180 41.13 32.06 6 1.1561 39.32 30.64 Limit (dBµV) Quai-peak 65.56 56.00 56.00 56.00 56.00 56.00 Average 55.56 46.00 46.00 46.00 46.00 46.00 Power-line Verdict Neutral PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 74 of 93 REPORT No.SZ23040024W03 A.9. Restricted Frequency Bands The lowest and highest channels are tested to verify the Restricted Frequency Bands. The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m Note: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (vertical) was recorded in this test report. 802.11b Mode Receiver Max. Channel Frequency (MHz) Detector PK/ AV Reading UR (dBµV) AT (dB) AFactor (dB@3m) Emission E (dBµV/m) Limit (dBµV/m) Verdict 1 2387.25 PK 24.13 6.74 27.20 58.07 74 PASS 1 2390.00 AV 11.84 6.74 27.20 45.78 54 PASS 13 2483.93 PK 25.49 6.74 27.20 59.43 74 PASS 13 2483.50 AV 16.80 6.74 27.20 50.74 54 PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 75 of 93 REPORT No.SZ23040024W03 (PEAK, Channel 1, 802.11b) (AVERAGE, Channel 1, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 76 of 93 REPORT No.SZ23040024W03 (PEAK, Channel 13, 802.11b) (AVERAGE, Channel 13, 802.11b) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 77 of 93 REPORT No.SZ23040024W03 802.11g Mode Receiver Max. Channel Frequency (MHz) Detector PK/ AV Reading UR (dBµV) AT (dB) AFactor (dB@3m) Emission E (dBµV/m) Limit (dBµV/m) Verdict 1 2389.60 PK 26.40 6.74 27.20 60.34 74 PASS 1 2389.82 AV 12.57 6.74 27.20 46.51 54 PASS 13 2485.26 PK 32.67 6.74 27.20 66.61 74 PASS 13 2483.96 AV 16.23 6.74 27.20 50.17 54 PASS (PEAK, Channel 1, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 78 of 93 REPORT No.SZ23040024W03 (AVERAGE, Channel 1, 802.11g) (PEAK, Channel 13, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 79 of 93 REPORT No.SZ23040024W03 (AVERAGE, Channel 13, 802.11g) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 80 of 93 REPORT No.SZ23040024W03 802.11n (HT20) Mode Receiver Max. Channel Frequency (MHz) Detector Reading UR AT (dB) AFactor (dB@3m) Emission E Limit (dBµV/m) Verdict PK/ AV (dBµV) (dBµV/m) 1 2390.00 PK 27.53 6.74 27.20 61.47 74 PASS 1 2389.60 AV 13.24 6.74 27.20 47.18 54 PASS 13 2485.90 PK 28.26 6.74 27.20 62.20 74 PASS 13 2483.58 AV 16.79 6.74 27.20 50.73 54 PASS (PEAK, Channel 1, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 81 of 93 REPORT No.SZ23040024W03 (AVERAGE, Channel 1, 802.11n (HT20)) (PEAK, Channel 13, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 82 of 93 REPORT No.SZ23040024W03 (AVERAGE, Channel 13, 802.11n (HT20)) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 83 of 93 REPORT No.SZ23040024W03 A.10. Radiated Emission According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average). The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 10th harmonic of the highest frequency, was pre-scanned and the result which was 20dB lower than the limit was not recorded. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 84 of 93 802.11b Mode Plot for Channel 1 REPORT No.SZ23040024W03 Fre. (MHz) 105.660 1902.400 2407.467 5680.000 8488.960 12166.480 PK (dBV/m) 33.04 47.84 47.40 48.10 48.06 48.65 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A 49.59 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 113.420 1602.133 1980.800 5606.080 8455.080 12887.200 PK (dBV/m) 32.91 47.34 47.79 47.31 47.81 49.10 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 85 of 93 Plot for Channel 7 REPORT No.SZ23040024W03 Fre. (MHz) 109.540 1639.467 2496.000 5248.800 9064.920 12881.040 PK (dBV/m) 33.03 47.25 47.76 46.92 48.19 49.23 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 101.780 1985.067 2490.667 5606.080 8892.440 12899.520 PK (dBV/m) 33.84 47.68 47.71 47.77 48.26 48.66 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 86 of 93 Plot for Channel 13 REPORT No.SZ23040024W03 Fre. (MHz) 94.990 1974.933 2452.800 5596.840 8464.320 11864.640 PK (dBV/m) 32.78 47.77 47.41 47.03 48.13 48.66 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 110.510 1410.667 2011.200 5649.200 7993.080 12659.280 PK (dBV/m) 33.10 47.35 47.57 47.52 47.35 48.67 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A 50.38 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 87 of 93 802.11g Mode Plot for Channel 1 REPORT No.SZ23040024W03 Fre. (MHz) 110.510 1912.533 2457.600 5763.160 10318.480 12141.840 PK (dBV/m) 32.56 48.05 47.61 47.84 47.80 48.04 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 112.450 1828.267 2409.067 5661.520 8442.760 12533.000 PK (dBV/m) 34.33 48.85 48.42 47.38 47.73 48.47 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 88 of 93 Plot for Channel 7 REPORT No.SZ23040024W03 Fre. (MHz) 106.630 1664.533 2462.933 5390.480 10962.200 12890.280 PK (dBV/m) 33.29 47.35 47.76 47.26 48.67 49.13 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 105.660 1765.333 2083.733 4752.920 8418.120 16789.560 PK (dBV/m) 33.82 48.20 48.12 47.12 47.88 48.97 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 89 of 93 Plot for Channel 13 REPORT No.SZ23040024W03 Fre. (MHz) 101.780 1613.333 2456.000 5676.920 8448.920 12616.160 PK (dBV/m) 34.31 47.76 48.61 47.60 48.23 48.19 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A 42.58 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 107.600 1584.533 2415.467 5402.800 7986.920 12539.160 PK (dBV/m) 33.87 48.14 48.24 47.45 47.64 48.51 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 90 of 93 802.11n (HT20) Mode Plot for Channel 1 REPORT No.SZ23040024W03 Fre. (MHz) 104.690 1955.733 2383.467 5806.280 8418.120 12683.920 PK (dBV/m) 33.23 47.72 48.18 48.44 48.75 48.34 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 107.600 1187.733 2081.600 5683.080 8418.120 12871.800 PK (dBV/m) 33.05 46.85 47.94 47.90 47.90 48.37 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 91 of 93 Plot for Channel 7 REPORT No.SZ23040024W03 Fre. (MHz) 100.810 1983.467 2449.600 5399.720 9160.400 12151.080 PK (dBV/m) 33.14 47.46 47.60 47.48 48.17 48.50 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 99.840 1749.867 2491.733 4531.160 8492.040 12603.840 PK (dBV/m) 33.01 47.93 48.07 47.58 47.92 48.23 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 92 of 93 Plot for Channel 13 REPORT No.SZ23040024W03 Fre. (MHz) 106.630 1897.067 2494.400 5683.080 8485.880 12289.680 PK (dBV/m) 33.38 47.69 47.92 48.70 48.42 48.72 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 18GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict PASS PASS PASS PASS PASS PASS Fre. (MHz) 108.570 1992.000 2451.733 5790.880 8427.360 12536.080 PK (dBV/m) 34.10 47.96 47.61 47.94 47.86 48.30 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 18GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS PASS PASS PASS PASS PASS END OF REPORT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 93 of 93Acrobat Distiller 9.3.2 (Windows)