REPORT No.SZ23040024W03
TEST REPORT

APPLICANT PRODUCT NAME MODEL NAME BRAND NAME FCC ID STANDARD(S) RECEIPT DATE TEST DATE ISSUE DATE

: BLU Products, Inc. : Smart Phone : C5L MAX : BLU : YHLBLUC5LMX175 : 47 CFR Part 15 Subpart C : 2023-04-03 : 2023-04-07 to 2023-05-23 : 2023-06-12

Edited by:

Zeng Xiaoying (Rapporteur)

Approved by: Shen Junsheng (Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 1 of 93

REPORT No.SZ23040024W03
DIRECTORY
1. Summary of Test Result  4 1.1. Testing Applied Standards  5 1.2. Test Equipment List  6 1.3. Measurement Uncertainty  8 1.4. Testing Laboratory 8 2. General Description  9 2.1. Information of Applicant and Manufacturer  9 2.2. Information of EUT 9 2.3. Channel List of EUT 10 2.4. Test Configuration of EUT 11 2.5. Test Conditions  11 2.6. Test Setup Layout Diagram 12 3. Test Results 15 3.1. Antenna Requirement 15 3.2. Duty Cycle of Test Signal 16 3.3. Maximum Peak and Average Conducted Output Power17 3.4. 6 dB Bandwidth 18 3.5. Conducted Spurious Emissions and Band Edge19 3.6. Power Spectral Density 20 3.7. Conducted Emission21 3.8. Restricted Frequency Bands 22 3.9. Radiated Emission23 Annex A Test Data and Result 25

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 2 of 93

Version 1.0

REPORT No.SZ23040024W03

Change History Date 2023-06-12

Reason for change First edition

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 3 of 93

1. Summary of Test Result

REPORT No.SZ23040024W03

No. Section Description

Test Date

Test Engineer

Result

Method Determination
/Remark

1 15.203

Antenna Requirement

N/A

N/A

PASS No deviation

2 N/A

Duty Cycle of Test Signal

Apr. 08, 2023

Zhong Yanshan

PASS

No deviation

3

15.247(b)

Maximum Peak Conducted Output Power

Apr. 08, 2023

Zhong Yanshan

PASS

No deviation

Maximum

4

15.247(b)

Average Conducted

Apr. 08, 2023

Zhong Yanshan

PASS

No deviation

Output Power

5 15.247(a) Bandwidth

Apr. 08, 2023

Zhong Yanshan

PASS

No deviation

Conducted

6

15.247(d)

Spurious Emission and

Apr. 17, 2023

Zhong Yanshan

PASS

No deviation

Band Edge

7

15.247(e)

Power Spectral Density

Apr. 17, 2023

Zhong Yanshan

PASS

No deviation

8 15.207

Conducted Emission

Apr. 12, 2023 Fan Zehang PASS No deviation

Restricted

9 15.247(d) Frequency

May 22, 2023 Li Hanbin PASS No deviation

Bands

10

15.209, 15.247(d)

Radiated Emission

Apr. 26, 2023 Li Hanbin PASS No deviation

Note 1: The tests were performed according to the method of measurements prescribed in

ANSIC63.10-2013 and KDB558074 D01 v05r02.

Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method

determination" column of add, deviate or exclude from the specific method shall be explained in the

"Remark" of the above table.

Note 3: When the test result is a critical value, we will use the measurement uncertainty give the

judgment result based on the 95% confidence intervals.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 4 of 93

1.1. Testing Applied Standards

REPORT No.SZ23040024W03

According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:  47 CFR Part 15 Subpart C Radio Frequency Devices

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 5 of 93

1.2. Test Equipment List

REPORT No.SZ23040024W03

1.2.1 Conducted Test Equipments

Equipment Name Serial No.

Type

EXA Signal Analzyer

MY53470836 N9010A

Power Sensor MY54180008 U2021XA

Attenuator

MTJ6004-20 VAT-10+

RF Cable (30MHz-26GHz)

CB01

RF01

Coaxial Cable

CB02

RF02

SMA Connector

CN01

RF03

Manufacturer
Agilent
Agilent MTJ Cooperation
Morlab
Morlab HUBER-SUHNER

Cal. Date 2023.02.27
2022.10.11 N/A N/A
N/A N/A

Due Date
2024.02.26
2023.10.10 N/A N/A N/A N/A

1.2.2 Conducted Emission Test Equipments

Equipment Name Serial No.

Type

Receiver

MY56400093 N9038A

LISN
Pulse Limiter (10dB)
RF Coaxial Cable (DC-100MHz)

8127449
VTSD 9561 F-B #206
BNC

NSLK 8127 VTSD 9561-F
MRE04

Manufacturer KEYSIGHT

Cal. Date Due Date 2023.02.09 2024.02.08

Schwarzbeck 2023.02.21 2024.02.20

Schwarzbeck 2022.07.06 2023.07.05

Qualwave

2022.07.08 2023.07.07

1.2.3 List of Software Used Description Test System
Morlab EMCR V1.2 TS+ -[JS32-CE]

Manufacturer MaiWei Morlab Tonscend

Software Version 2.0.0.0 V1.0 V2.5.0.0

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 6 of 93

REPORT No.SZ23040024W03

1.2.4 Radiated Test Equipments

Equipment Name

Serial No.

Receiver

MY54130016

Test Antenna Bi-Log

9163-519

Test Antenna Loop

1519-022

Test Antenna ­ Horn

01774

Test Antenna ­ BBHA9170

Horn

#773

Preamplifier (10MHz-6GHz)

46732

Preamplifier (2GHz-18GHz)

61171/61172

Preamplifier (18GHz-40GHz)

DS77209

Type N9038A VULB 9163
FMZB1519
BBHA 9120D
BBHA9170 S10M100L38
02 S020180L32
03 DCLNA0118-
40C-S

RF Coaxial Cable (DC-18GHz)

MRE001

PE330

RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-18GHz)
Notch Filter
Anechoic Chamber

MRE002 MRE003 22290045 22290046 22120181
N/A N/A

CLU18
CLU18
QA360-40-K K-0.5
QA360-40-K KF-2
QA500-18-N N-5
WRCG-24002483.5-60SS
9m*6m*6m

Manufacturer Agilent
Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP.
Decentest
Pasternack
Pasternack Pasternack Qualwave Qualwave Qualwave Wainwright
CRT

Cal. Date 2022.07.06 2022.05.25 2022.02.11 2022.07.13 2022.07.14 2022.07.08 2022.07.08 2022.07.23
2022.07.08
2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.07.08 2022.05.10

Due Date 2023.07.05 2025.05.24 2025.02.10 2025.07.12 2025.07.13 2023.07.07 2023.07.07 2023.07.22
2023.07.07
2023.07.07 2023.07.07 2023.07.07 2023.07.07 2023.07.07 2023.07.07 2025.05.09

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 7 of 93

1.3. Measurement Uncertainty

REPORT No.SZ23040024W03

Test Items Peak Output Power Power Spectral Density Bandwidth Conducted Spurious Emission Restricted Frequency Bands Radiated Emission Conducted Emission
1.4. Testing Laboratory

Uncertainty ±2.22dB ±2.22dB ±5% ±2.77dB ±5% ±2.95dB ±2.44dB

Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95%

Laboratory Name
Laboratory Address
Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192
226174

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 8 of 93

2. General Description

REPORT No.SZ23040024W03

2.1. Information of Applicant and Manufacturer

Applicant Applicant Address Manufacturer Manufacturer Address

BLU Products, Inc. 8600 NW 36th Street, Suite #200 Doral, FL 33166, USA BLU Products, Inc. 8600 NW 36th Street, Suite #200 Doral, FL 33166, USA

2.2. Information of EUT

Product Name: Sample No.: Hardware Version: Software Version: Modulation Technology: Modulation Type: Operating Frequency Range: Antenna Type: Antenna Gain:
Accessory Information:

Smart Phone

1#

A507-MB-V3.6D

A507-37H_sp9832e_1h10_go2g-userdebug-native_0307_144 3 DSSS, OFDM

Refer to section1.3

802.11b/g/ n (HT20): 2412MHz­2472MHz

PIFA Antenna

-0.62dBi

Battery

Brand Name: BLU

Model No.:

C775444200L

Serial No.:

N/A

Capacity:

2000mAh

Rated Voltage: 3.8V

Charge Limit: 4.35V

Manufacturer: Shenzhen Aerospace Electronic Co.,Ltd.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 9 of 93

REPORT No.SZ23040024W03

Adaptor

Brand Name: BLU

Model No.:

US-JY-1000

Accessory Information:

Serial No.: Rated Output:

N/A 5V 1000mA

Rated Input:

100-240V 50/60Hz, 0.3A

Manufacturer:

Dongguan Jieyuan Electronic Technology Co., LTD

Note 1: We use the dedicated software to control the EUT continuous transmission.

Note 2: For a more detailed description, please refer to Specification or User's Manual supplied by

the applicant and/or manufacturer.

2.3. Channel List of EUT

Test Mode

Channel Frequency (MHz)

1

2412

2

2417

3

2422

802.11b/g/n (HT20)

4

2427

5

2432

6

2437

7

2442

Note 1: The black bold channels were selected for test.

Channel
8 9 10 11 12 13

Frequency (MHz)
2447 2452 2457 2462 2467 2472

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 10 of 93

2.4. Test Configuration of EUT

REPORT No.SZ23040024W03

2.4.1.Modulation Type and Data Rate of EUT

Modulation technology

Modulation Type

Data Rate (Mbps) Note1

DBPSK

1

DSSS (802.11b)

DQPSK

2

CCK

5.5/ 11

BPSK

6 / 9

OFDM (802.11g)

QPSK 16QAM

12 / 18 24 / 36

64QAM

48 / 54

BPSK

6.5

OFDM

QPSK

13/19.5

(802.11n (HT20))

16QAM

26/39

64QAM

52/58.5/65

Note1: The worst-case mode (bold face) in all data rates has been determined during the pre-scan,

only the test data of the worst-case were recorded in this report.

Note2: The RF signal transmission of EUT is controlled by the build-in engineering mode which is

provided by the manufacturer. The recorded power setting value is the maximum that the

engineering mode has configuration during testing.

2.5. Test Conditions

Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa)

15-35 30-60 86-106

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 11 of 93

2.6. Test Setup Layout Diagram
2.6.1.Conducted Measurement Power item

REPORT No.SZ23040024W03

Other items

2.6.2.Conducted Emission Measurement

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 12 of 93

2.6.3.Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz

REPORT No.SZ23040024W03

2) For radiated emissions from 30MHz to1GHz

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 13 of 93

3) For radiated emissions above 1GHz

REPORT No.SZ23040024W03

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 14 of 93

3. Test Results

REPORT No.SZ23040024W03

3.1. Antenna Requirement

3.1.1.Requirement
According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section.

3.1.2.Test Result
Inside of the EUT has a PIFA antenna coupled with the metal shrapnel. Please refer to the EUT internal photos.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 15 of 93

3.2. Duty Cycle of Test Signal

REPORT No.SZ23040024W03

3.2.1.Requirement
Preferably, all measurements of maximum conducted (average) output power will be performed with the EUT transmitting continuously (i.e., with a duty cycle of greater than or equal to 98%).When continuous operation cannot be realized, then the use of sweep triggering/signal gating techniques can be used to ensure that measurements are made only during transmissions at the maximum power control level. Such sweep triggering/signal gating techniques will require knowledge of the minimum transmission duration(T) over which the transmitter is on and is transmitting at its maximum power control level for the tested mode of operation. Sweep triggering/signal gating techniques can then be used if the measurement/sweep time of the analyzer can be set such that it does not exceed T at any time that data are being acquired (i.e.,no transmitter OFF-time is to be considered). When continuous transmission cannot be achieved and sweep triggering/signal gating cannot be implemented, alternative procedures are provided that can be used to measure the average power; however, they will require an additional measurement of the transmitter duty cycle (D). Within this sub clause, the duty cycle refers to the fraction of time over which the transmitter is ON and is transmitting at its maximum power control level. The duty cycle is considered to be constant if variations are less than ±2%; otherwise, the duty cycle is considered to be non constant.

3.2.2.Test Result Refer to Annex A.1 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 16 of 93

REPORT No.SZ23040024W03
3.3. Maximum Peak and Average Conducted Output Power
3.3.1.Requirement
According to FCC section 15.247(b)(3), For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: The maximum conducted output power of the intentional radiator shall not exceed 1 Watt.
3.3.2.Test Procedures
The EUT (Equipment under the test) which is coupled to the USB Wideband Power Sensor; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading.
3.3.3.Test Setup Layout
Refer to chapter 2.6.1 in this report.
3.3.4.Test Result Refer to Annex A.2 and A.3 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 17 of 93

3.4. 6 dB Bandwidth

REPORT No.SZ23040024W03

3.4.1.Requirement
According to FCC section 15.247(a) (2), systems using digital modulation techniques may operate in the 902 - 928 MHz, 2400 - 2483.5 MHz, and 5725 - 5850 MHz bands. The minimum 6dB bandwidth shall be at least 500 kHz.

3.4.1.Test Procedures KDB 558074 Section 8.2 was used in order to prove compliance.

3.4.2.Test Setup Layout Refer to chapter 2.6.1 in this report.

3.4.3.Test Result Refer to Annex A.4 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 18 of 93

REPORT No.SZ23040024W03
3.5. Conducted Spurious Emissions and Band Edge
3.5.1.Requirement
According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement.
3.5.2.Test Procedures
KDB 558074 Section 8.5 and 8.7 was used in order to prove compliance.
3.5.3.Test Setup Layout
Refer to chapter 2.6.1 in this report.
3.5.4.Test Result Refer to Annex A.5 and A.6 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 19 of 93

3.6. Power Spectral Density

REPORT No.SZ23040024W03

3.6.1.Requirement
For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral density shall be determined in accordance with the provisions of paragraph (b) of this section. The same method of determining the conducted output power shall be used to determine the power spectral density.

3.6.2.Test Procedures
The measured power spectral density was calculated by the reading of the spectrum analyzer and calibration. Following is the test procedure for PSD test: a) Set analyzer center frequency to channel center frequency b) Set span to1.5 times DTS c) Set RBW to 30kHz d) Set VBW to 100kHz e) Detector = peak f) Sweep time = auto couple g) Trace mode = max hold h) Allow trace to fully stabilize i) Use the peak marker function to determine the maximum amplitude level and recorded as PD j) Use below formula to calculate the Conducted PSD value that at specified RBW: Conducted PSD=PD-10lg(30k/3k)

3.6.3.Test Setup Layout Refer to chapter 2.6.1 in this report.

3.6.4.Test Result Refer to Annex A.7 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 20 of 93

3.7. Conducted Emission

REPORT No.SZ23040024W03

3.7.1.Requirement

According to FCC section 15.207, for an intentional radiator that is designed to be connected to the

public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power

line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following

table, as measured using a 50µH/50 line impedance stabilization network (LISN).

Frequency Range (MHz)

Conducted Limit (dBµV)

Quai-peak

Average

0.15 - 0.50

66 to 56

56 to 46

0.50 - 5

56

46

5 - 30

60

50

Note:

(a) The lower limit shall apply at the band edges.

(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.

3.7.2.Test Procedures
The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013.

3.7.3.Test Setup Layout Refer to chapter 2.6.2 in this report.

3.7.4.Test Result Refer to Annex A.8 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 21 of 93

3.8. Restricted Frequency Bands

REPORT No.SZ23040024W03

3.8.1.Requirement
According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a).

3.8.2.Test Procedures
The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f  1GHz, 100 kHz for f < 1GHz VBW = 3 MHz Sweep = auto Detector function = peak/average Trace = max hold Allow the trace to stabilize

3.8.3.Test Setup Layout Refer to chapter 2.6.3 in this report.

3.8.4.Test Result Refer to Annex A.9 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 22 of 93

3.9. Radiated Emission

REPORT No.SZ23040024W03

3.9.1.Requirement

According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a).

According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions

from an intentional radiator shall not exceed the field strength levels specified in the following table:

Frequency (MHz)

Field Strength (µV/m)

Measurement Distance (m)

0.009 - 0.490

2400/F(kHz)

300

0.490 - 1.705

24000/F(kHz)

30

1.705 - 30.0

30

30

30 - 88

100

3

88 - 216

150

3

216 - 960

200

3

Above 960

500

3

Note1: For above 1000MHz, the emission limit in this paragraph is based on measurement

instrumentation employing an average detector, measurement using instrumentation with a peak

detector function, corresponding to 20dB above the maximum permitted average limit.

Note2:For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and

74dBuV/m@3m (PK).In addition, radiated emissions which fall in the restricted bands, as defined

in Section 15.205(a), also should comply with the radiated emission limits specified in Section

15.209(a)(above table).

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 23 of 93

3.9.2.Test Procedures

REPORT No.SZ23040024W03

The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode.
For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector.
For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak.
For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements.
The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response.

3.9.3.Test Setup Layout

Refer to chapter 2.6.3 in this report.

3.9.4.Test Result

Refer to Annex A.10 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 24 of 93

REPORT No.SZ23040024W03
Annex A Test Data and Result

A.1. Duty Cycle of Test Signal

Condition NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT

Mode b b b g g g
n20 n20 n20

Frequency (MHz) 2412 2442 2472 2412 2442 2472 2412 2442 2472

Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

Duty Cycle (%) 99.71 99.71 99.71 98.48 98.39 98.02 97.87 98.27 98.27

Correction Factor (dB) 0.01 0.01 0.01 0.07 0.07 0.09 0.09 0.08 0.08

1/T (kHz) 0.08 0.08 0.08 0.48 0.48 0.48 0.52 0.52 0.52

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 25 of 93

REPORT No.SZ23040024W03
Test Graphs Duty Cycle NVNT b 2412MHz Ant1
Duty Cycle NVNT b 2442MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 26 of 93

REPORT No.SZ23040024W03
Duty Cycle NVNT b 2472MHz Ant1
Duty Cycle NVNT g 2412MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 27 of 93

REPORT No.SZ23040024W03
Duty Cycle NVNT g 2442MHz Ant1
Duty Cycle NVNT g 2472MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 28 of 93

REPORT No.SZ23040024W03
Duty Cycle NVNT n20 2412MHz Ant1
Duty Cycle NVNT n20 2442MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 29 of 93

REPORT No.SZ23040024W03
Duty Cycle NVNT n20 2472MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 30 of 93

REPORT No.SZ23040024W03

A.2. Maximum Peak Conducted Output Power

Frequency

Conducted

Condition Mode

Antenna

(MHz)

Power (dBm)

NVNT

b

NVNT

b

NVNT

b

NVNT

g

NVNT

g

NVNT

g

NVNT

n20

NVNT

n20

NVNT

n20

2412 2442 2472 2412 2442 2472 2412 2442 2472

Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

18.13 18.26 18.1 20.49 20.31 18.50 19.20 18.55 17.56

Duty Factor
(dB) 0 0 0 0 0 0 0 0 0

Total Power (dBm) 18.13 18.26
18.1 20.49 20.31 18.50 19.20 18.55 17.56

Limit Verdict
(dBm)

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 31 of 93

REPORT No.SZ23040024W03
Test Graphs Peak Power NVNT b 2412MHz Ant1
Peak Power NVNT b 2442MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 32 of 93

REPORT No.SZ23040024W03
Peak Power NVNT b 2472MHz Ant1
Peak Power NVNT g 2412MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 33 of 93

REPORT No.SZ23040024W03
Peak Power NVNT g 2442MHz Ant1
Peak Power NVNT g 2472MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 34 of 93

REPORT No.SZ23040024W03
Peak Power NVNT n20 2412MHz Ant1
Peak Power NVNT n20 2442MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 35 of 93

REPORT No.SZ23040024W03
Peak Power NVNT n20 2472MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 36 of 93

REPORT No.SZ23040024W03

A.3. Maximum Average Conducted Output Power

Frequency

Conducted

Condition Mode

Antenna

(MHz)

Power (dBm)

NVNT

b

NVNT

b

NVNT

b

NVNT

g

NVNT

g

NVNT

g

NVNT

n20

NVNT

n20

NVNT

n20

2412 2442 2472 2412 2442 2472 2412 2442 2472

Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

15.61 15.20 15.51 13.51 13.22 11.18 11.57 11.00 10.12

Duty Factor
(dB) 0.01 0.01 0.01 0.07 0.07 0.09 0.09 0.08 0.08

Total Power (dBm) 15.62 15.21 15.52 13.58 13.29 11.27 11.66 11.08
10.2

Limit Verdict
(dBm)

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

30

Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 37 of 93

REPORT No.SZ23040024W03
Test Graphs Average Power NVNT b 2412MHz Ant1
Average Power NVNT b 2442MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 38 of 93

REPORT No.SZ23040024W03
Average Power NVNT b 2472MHz Ant1
Average Power NVNT g 2412MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 39 of 93

REPORT No.SZ23040024W03
Average Power NVNT g 2442MHz Ant1
Average Power NVNT g 2472MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 40 of 93

REPORT No.SZ23040024W03
Average Power NVNT n20 2412MHz Ant1
Average Power NVNT n20 2442MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 41 of 93

REPORT No.SZ23040024W03
Average Power NVNT n20 2472MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 42 of 93

REPORT No.SZ23040024W03

A.4. 6 dB Bandwidth

Condition Mode

NVNT

b

NVNT

b

NVNT

b

NVNT

g

NVNT

g

NVNT

g

NVNT

n20

NVNT

n20

NVNT

n20

Frequency (MHz) 2412 2442 2472 2412 2442 2472 2412 2442 2472

Antenna
Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

-6 dB Bandwidth (MHz) 8.569 9.095 8.611 14.415 16.369 16.366 17.298 17.582 17.283

Limit -6 dB Bandwidth (MHz) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5

Verdict
Pass Pass Pass Pass Pass Pass Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 43 of 93

REPORT No.SZ23040024W03
Test Graphs -6dB Bandwidth NVNT b 2412MHz Ant1
-6dB Bandwidth NVNT b 2442MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 44 of 93

REPORT No.SZ23040024W03
-6dB Bandwidth NVNT b 2472MHz Ant1
-6dB Bandwidth NVNT g 2412MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 45 of 93

REPORT No.SZ23040024W03
-6dB Bandwidth NVNT g 2442MHz Ant1
-6dB Bandwidth NVNT g 2472MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 46 of 93

REPORT No.SZ23040024W03
-6dB Bandwidth NVNT n20 2412MHz Ant1
-6dB Bandwidth NVNT n20 2442MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 47 of 93

REPORT No.SZ23040024W03
-6dB Bandwidth NVNT n20 2472MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 48 of 93

REPORT No.SZ23040024W03

A.5. Conducted Spurious Emissions

Condition NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT

Mode b b b g g g
n20 n20 n20

Frequency (MHz) 2412 2442 2472 2412 2442 2472 2412 2442 2472

Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

Max Value (dBc) -35.48 -29.86 -35.35 -29.01 -26.98 -29.55 -27.95 -24.32 -28.06

Limit (dBc) -20 -20 -20 -20 -20 -20 -20 -20 -20

Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 49 of 93

REPORT No.SZ23040024W03
Test Graphs Tx. Spurious NVNT b 2412MHz Ant1 Ref
Tx. Spurious NVNT b 2412MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 50 of 93

REPORT No.SZ23040024W03
Tx. Spurious NVNT b 2442MHz Ant1 Ref
Tx. Spurious NVNT b 2442MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 51 of 93

REPORT No.SZ23040024W03
Tx. Spurious NVNT b 2472MHz Ant1 Ref
Tx. Spurious NVNT b 2472MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 52 of 93

REPORT No.SZ23040024W03
Tx. Spurious NVNT g 2412MHz Ant1 Ref
Tx. Spurious NVNT g 2412MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 53 of 93

REPORT No.SZ23040024W03
Tx. Spurious NVNT g 2442MHz Ant1 Ref
Tx. Spurious NVNT g 2442MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 54 of 93

REPORT No.SZ23040024W03
Tx. Spurious NVNT g 2472MHz Ant1 Ref
Tx. Spurious NVNT g 2472MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 55 of 93

REPORT No.SZ23040024W03
Tx. Spurious NVNT n20 2412MHz Ant1 Ref
Tx. Spurious NVNT n20 2412MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 56 of 93

REPORT No.SZ23040024W03
Tx. Spurious NVNT n20 2442MHz Ant1 Ref
Tx. Spurious NVNT n20 2442MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 57 of 93

REPORT No.SZ23040024W03
Tx. Spurious NVNT n20 2472MHz Ant1 Ref
Tx. Spurious NVNT n20 2472MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 58 of 93

REPORT No.SZ23040024W03

A.6. Band Edge

Condition NVNT NVNT NVNT NVNT NVNT NVNT

Mode b b g g
n20 n20

Frequency (MHz) 2412 2472 2412 2472 2412 2472

Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

Max Value (dBc) -50.52 -38.29 -36.60 -29.42 -35.27 -31.41

Limit (dBc) -20 -20 -20 -20 -20 -20

Verdict Pass Pass Pass Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 59 of 93

REPORT No.SZ23040024W03
Test Graphs Band Edge NVNT b 2412MHz Ant1 Ref
Band Edge NVNT b 2412MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 60 of 93

REPORT No.SZ23040024W03
Band Edge NVNT b 2472MHz Ant1 Ref
Band Edge NVNT b 2472MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 61 of 93

REPORT No.SZ23040024W03
Band Edge NVNT g 2412MHz Ant1 Ref
Band Edge NVNT g 2412MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 62 of 93

REPORT No.SZ23040024W03
Band Edge NVNT g 2472MHz Ant1 Ref
Band Edge NVNT g 2472MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 63 of 93

REPORT No.SZ23040024W03
Band Edge NVNT n20 2412MHz Ant1 Ref
Band Edge NVNT n20 2412MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 64 of 93

REPORT No.SZ23040024W03
Band Edge NVNT n20 2472MHz Ant1 Ref
Band Edge NVNT n20 2472MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 65 of 93

REPORT No.SZ23040024W03

A.7. Power Spectral Density

Condition
NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT

Mode
b b b g g g n20 n20 n20

Frequency (MHz)
2412 2442 2472 2412 2442 2472 2412 2442 2472

Antenna
Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

Conducted PSD
(dBm/3kHz) -7.03 -9.27 -4.29 -14.74 -16.78 -11.88 -14.3 -19.21 -14.05

Duty Factor
(dB) 0 0 0 0 0 0 0 0 0

Total PSD (dBm/3kHz)
-7.03 -9.27 -4.29 -14.74 -16.78 -11.88 -14.3 -19.21 -14.05

Limit (dBm/3kHz)
8 8 8 8 8 8 8 8 8

Verdict
Pass Pass Pass Pass Pass Pass Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 66 of 93

REPORT No.SZ23040024W03
Test Graphs PSD NVNT b 2412MHz Ant1
PSD NVNT b 2442MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 67 of 93

REPORT No.SZ23040024W03
PSD NVNT b 2472MHz Ant1
PSD NVNT g 2412MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 68 of 93

REPORT No.SZ23040024W03
PSD NVNT g 2442MHz Ant1
PSD NVNT g 2472MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 69 of 93

REPORT No.SZ23040024W03
PSD NVNT n20 2412MHz Ant1
PSD NVNT n20 2442MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 70 of 93

REPORT No.SZ23040024W03
PSD NVNT n20 2472MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 71 of 93

REPORT No.SZ23040024W03
A.8. Conducted Emission
The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT + Adapter + USB Cable + Earphone +WIFI TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 72 of 93

B. Test Plot:

REPORT No.SZ23040024W03

(L Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.1635

39.31

27.87

2 0.1941

37.99

28.05

3 0.4376

31.16

25.17

4 0.5482

39.43

31.86

5 0.5739

42.11

33.69

6 1.3080

32.72

25.68

Limit (dBµV)

Quai-peak 65.28 63.86 57.11 56.00 56.00 56.00

Average 55.28 53.86 47.11 46.00 46.00 46.00

Power-line Verdict

PASS

PASS

Line

PASS PASS

PASS

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 73 of 93

REPORT No.SZ23040024W03

(N Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.1582

41.70

30.74

2 0.5480

48.90

38.32

3 0.5832

49.38

39.24

4 0.6086

43.71

33.08

5 0.7180

41.13

32.06

6 1.1561

39.32

30.64

Limit (dBµV)

Quai-peak 65.56 56.00 56.00 56.00 56.00 56.00

Average 55.56 46.00 46.00 46.00 46.00 46.00

Power-line Verdict

Neutral

PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 74 of 93

REPORT No.SZ23040024W03

A.9. Restricted Frequency Bands

The lowest and highest channels are tested to verify the Restricted Frequency Bands. The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m
Note: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (vertical) was recorded in this test report.

802.11b Mode

Receiver

Max.

Channel

Frequency (MHz)

Detector PK/ AV

Reading UR
(dBµV)

AT (dB)

AFactor (dB@3m)

Emission E
(dBµV/m)

Limit (dBµV/m)

Verdict

1

2387.25

PK

24.13 6.74 27.20

58.07

74

PASS

1

2390.00

AV

11.84 6.74 27.20

45.78

54

PASS

13

2483.93

PK

25.49 6.74 27.20

59.43

74

PASS

13

2483.50

AV

16.80 6.74 27.20

50.74

54

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 75 of 93

REPORT No.SZ23040024W03

(PEAK, Channel 1, 802.11b)

(AVERAGE, Channel 1, 802.11b)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 76 of 93

REPORT No.SZ23040024W03

(PEAK, Channel 13, 802.11b)

(AVERAGE, Channel 13, 802.11b)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 77 of 93

REPORT No.SZ23040024W03

802.11g Mode

Receiver

Max.

Channel

Frequency (MHz)

Detector PK/ AV

Reading UR
(dBµV)

AT (dB)

AFactor (dB@3m)

Emission E
(dBµV/m)

Limit (dBµV/m)

Verdict

1

2389.60

PK

26.40 6.74 27.20

60.34

74

PASS

1

2389.82

AV

12.57 6.74 27.20

46.51

54

PASS

13

2485.26

PK

32.67 6.74 27.20

66.61

74

PASS

13

2483.96

AV

16.23 6.74 27.20

50.17

54

PASS

(PEAK, Channel 1, 802.11g)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 78 of 93

REPORT No.SZ23040024W03

(AVERAGE, Channel 1, 802.11g)

(PEAK, Channel 13, 802.11g)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 79 of 93

REPORT No.SZ23040024W03
(AVERAGE, Channel 13, 802.11g)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 80 of 93

REPORT No.SZ23040024W03

802.11n (HT20) Mode

Receiver

Max.

Channel

Frequency (MHz)

Detector

Reading UR

AT (dB)

AFactor (dB@3m)

Emission E

Limit (dBµV/m)

Verdict

PK/ AV (dBµV)

(dBµV/m)

1

2390.00

PK

27.53 6.74 27.20

61.47

74

PASS

1

2389.60

AV

13.24 6.74 27.20

47.18

54

PASS

13

2485.90

PK

28.26 6.74 27.20

62.20

74

PASS

13

2483.58

AV

16.79 6.74 27.20

50.73

54

PASS

(PEAK, Channel 1, 802.11n (HT20))

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 81 of 93

REPORT No.SZ23040024W03

(AVERAGE, Channel 1, 802.11n (HT20))

(PEAK, Channel 13, 802.11n (HT20))

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 82 of 93

REPORT No.SZ23040024W03
(AVERAGE, Channel 13, 802.11n (HT20))

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 83 of 93

REPORT No.SZ23040024W03
A.10. Radiated Emission
According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average).
The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 10th harmonic of the highest frequency, was pre-scanned and the result which was 20dB lower than the limit was not recorded.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 84 of 93

802.11b Mode Plot for Channel 1

REPORT No.SZ23040024W03

Fre. (MHz)
105.660 1902.400 2407.467 5680.000 8488.960 12166.480

PK (dBV/m)
33.04 47.84
47.40
48.10 48.06
48.65

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

49.59

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
113.420 1602.133 1980.800 5606.080 8455.080 12887.200

PK (dBV/m)
32.91 47.34
47.79 47.31
47.81
49.10

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 85 of 93

Plot for Channel 7

REPORT No.SZ23040024W03

Fre. (MHz)
109.540 1639.467 2496.000 5248.800 9064.920 12881.040

PK (dBV/m)
33.03
47.25 47.76
46.92
48.19 49.23

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
101.780 1985.067 2490.667 5606.080 8892.440 12899.520

PK (dBV/m)
33.84 47.68
47.71
47.77 48.26
48.66

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 86 of 93

Plot for Channel 13

REPORT No.SZ23040024W03

Fre. (MHz)
94.990 1974.933 2452.800 5596.840 8464.320 11864.640

PK (dBV/m)
32.78
47.77 47.41
47.03
48.13 48.66

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
110.510 1410.667 2011.200 5649.200 7993.080 12659.280

PK (dBV/m)
33.10
47.35 47.57
47.52 47.35
48.67

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

50.38

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 87 of 93

802.11g Mode Plot for Channel 1

REPORT No.SZ23040024W03

Fre. (MHz)
110.510 1912.533 2457.600 5763.160 10318.480 12141.840

PK (dBV/m)
32.56 48.05
47.61
47.84 47.80
48.04

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
112.450 1828.267 2409.067 5661.520 8442.760 12533.000

PK (dBV/m)
34.33
48.85
48.42 47.38
47.73 48.47

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 88 of 93

Plot for Channel 7

REPORT No.SZ23040024W03

Fre. (MHz)
106.630 1664.533 2462.933 5390.480 10962.200 12890.280

PK (dBV/m)
33.29
47.35 47.76
47.26
48.67 49.13

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
105.660 1765.333 2083.733 4752.920 8418.120 16789.560

PK (dBV/m)
33.82 48.20
48.12
47.12 47.88
48.97

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 89 of 93

Plot for Channel 13

REPORT No.SZ23040024W03

Fre. (MHz)
101.780 1613.333 2456.000 5676.920 8448.920 12616.160

PK (dBV/m)
34.31
47.76 48.61
47.60
48.23 48.19

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

42.58

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
107.600 1584.533 2415.467 5402.800 7986.920 12539.160

PK (dBV/m)
33.87 48.14
48.24
47.45 47.64
48.51

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 90 of 93

802.11n (HT20) Mode Plot for Channel 1

REPORT No.SZ23040024W03

Fre. (MHz)
104.690 1955.733 2383.467 5806.280 8418.120 12683.920

PK (dBV/m)
33.23 47.72
48.18
48.44 48.75
48.34

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
107.600 1187.733 2081.600 5683.080 8418.120 12871.800

PK (dBV/m)
33.05 46.85
47.94 47.90
47.90
48.37

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 91 of 93

Plot for Channel 7

REPORT No.SZ23040024W03

Fre. (MHz)
100.810 1983.467 2449.600 5399.720 9160.400 12151.080

PK (dBV/m)
33.14
47.46 47.60
47.48
48.17 48.50

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
99.840 1749.867 2491.733 4531.160 8492.040 12603.840

PK (dBV/m)
33.01 47.93
48.07
47.58 47.92
48.23

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 92 of 93

Plot for Channel 13

REPORT No.SZ23040024W03

Fre. (MHz)
106.630 1897.067 2494.400 5683.080 8485.880 12289.680

PK (dBV/m)
33.38
47.69 47.92
48.70
48.42 48.72

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
108.570 1992.000 2451.733 5790.880 8427.360 12536.080

PK (dBV/m)
34.10
47.96
47.61 47.94
47.86 48.30

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

END OF REPORT