Instruction Manual for Functional Devices models including: RIBTW2421B-BCIP BACnet IP Relay Device, RIBTW2421B-BCIP, BACnet IP Relay Device, Relay Device, Device
RIBTW2421B-BCIP - Functional Devices, Inc.
File Info : application/pdf, 2 Pages, 248.49KB
DocumentDocument} } } } 101 Commerce Drive | Sharpsville, IN 46068 800-888-5538 | support@functionaldevices.com Product Description BACnet IP Relay Device, One Binary Output + Override, One Binary Input, 24 Vac/dc / 120-277 Vac Power Input, NEMA 1 Housing BACnet Details · Device ID will default to 277XXX where XXX is the decimal value of the last octet of the device's MAC address Examples: MAC Address D8:47:8F:23:97:9E Hexadecimal 9E = Decimal 158 Device ID 277158 MAC Address D8:47:8F:23:9F:20 Hexadecimal 20 = Decimal 32 Device ID 277032 · Device ID can be changed with a BACnet configuration tool or on the product's webpage via an internet browser. · This model utilizes: BO1 (Relay output), BI1 (Dry Contact Binary Input), NP1 (Network Port Object) · PIC Statement and Datasheet available on website: www.functionaldevices.com RIBTW2421B-BCIP Bulletin 3703 393003 15M6 BLUE LED = Heartbeat GREEN LED = Network Communication YELLOW LED = Link Status RJ45 LAN **CAUTION** This RJ45 connection is for LAN only. Do Not Connect POE. Relay Override 2 Reset Push Button 1 1 0 RED LED =Relay Status PINK LED = Binary Input Status Dry Contact Binary Input 24 Vac/dc Common Relay Override DIP Switches Relay 1 2 State* 0 1 Auto 1 x Activated 0 0 Deactivated *Device must be powered for override 101 Commerce Drive | Sharpsville, IN 46068 800-888-5538 | support@functionaldevices.com Product Description BACnet IP Relay Device, One Binary Output + Override, One Binary Input, 24 Vac/dc / 120-277 Vac Power Input, NEMA 1 Housing BACnet Details · Device ID will default to 277XXX where XXX is the decimal value of the last octet of the device's MAC address Examples: MAC Address D8:47:8F:23:97:9E Hexadecimal 9E = Decimal 158 Device ID 277158 MAC Address D8:47:8F:23:9F:20 Hexadecimal 20 = Decimal 32 Device ID 277032 · Device ID can be changed with a BACnet configuration tool or on the product's webpage via an internet browser. · This model utilizes: BO1 (Relay output), BI1 (Dry Contact Binary Input), NP1 (Network Port Object) · PIC Statement and Datasheet available on website: www.functionaldevices.com RIBTW2421B-BCIP Bulletin 3703 393003 15M6 BLUE LED = Heartbeat GREEN LED = Network Communication YELLOW LED = Link Status RJ45 LAN **CAUTION** This RJ45 connection is for LAN only. Do Not Connect POE. Relay Override 2 Reset Push Button 1 1 0 RED LED =Relay Status PINK LED = Binary Input Status Dry Contact Binary Input 24 Vac/dc Common Relay Override DIP Switches Relay 1 2 State* 0 1 Auto 1 x Activated 0 0 Deactivated *Device must be powered for override Configuration Details This product defaults to DHCP mode when connected to a network. Using a Discovery tool, add the device to a network, and make note of the IP Address assigned. Open a web browser and type the device's IP Address into the URL bar. The product serves three web pages: 1. The main page shows the status of the unit's Binary Input and Binary Output. 2. The second page shows the BACnet Objects and Properties. From here, properties can be read and written. 3. The third page shows the Network configuration details. From here the device can be switched from DHCP to Static IP mode, and the device's address can be changed. LED Definitions Yellow LED Link status (network connected) Green LED Network communication Blue LED Heartbeat Red LED Relay status (Binary Output 1) Pink LED Dry Contact Input status (Binary Input 1) Relay Override (Local DIP Switch) See the diagram on the other side of this sheet. Reset Pushbutton To restore the unit to its defaults, hold the Reset Pushbutton for 5 seconds. The Blue LED will blink rapidly and then stay on for a few seconds. This indicates that the device is resetting. When the LED begins to blink slowly again (heartbeat), the device has been Reset. Powering device with 24 Vac When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 Note in Diagram Below ^^ 24 Vac RIBTW2421B-BCIP 24 Vac/dc Comm Half-Wave Device 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s). Configuration Details This product defaults to DHCP mode when connected to a network. Using a Discovery tool, add the device to a network, and make note of the IP Address assigned. Open a web browser and type the device's IP Address into the URL bar. The product serves three web pages: 1. The main page shows the status of the unit's Binary Input and Binary Output. 2. The second page shows the BACnet Objects and Properties. From here, properties can be read and written. 3. The third page shows the Network configuration details. From here the device can be switched from DHCP to Static IP mode, and the device's address can be changed. LED Definitions Yellow LED Link status (network connected) Green LED Network communication Blue LED Heartbeat Red LED Relay status (Binary Output 1) Pink LED Dry Contact Input status (Binary Input 1) Relay Override (Local DIP Switch) See the diagram on the other side of this sheet. Reset Pushbutton To restore the unit to its defaults, hold the Reset Pushbutton for 5 seconds. The Blue LED will blink rapidly and then stay on for a few seconds. This indicates that the device is resetting. When the LED begins to blink slowly again (heartbeat), the device has been Reset. Powering device with 24 Vac When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 Note in Diagram Below ^^ 24 Vac RIBTW2421B-BCIP 24 Vac/dc Comm Half-Wave Device 24 Vac Comm IN4004 ^^ Option 2: Add diode on 24 Vac power (Comm) interconnection between devices. Band on diode faces towards RIB(s).