3.5 Ton Oxbox by Trane 14.3 SEER2 Single Stage Air Conditioner Condenser | National Air Warehouse
J4AC5042E1000AA TAG: _________________________________ S UBM IT TA L 3.5 Ton Split System Air Conditioner - 1 Phase J4AC5042E1000AA SERVICE ACCESS ALLOW 24" CLEARANCE POWER WIRING 7/8" (22.2mm) SERVICE FITTING LIQUID LINE CONNECTION Product Specifications OUTDOOR UNIT J4AC5042E1000AA W POWER CONNS. -- V/PH/HZ MIN. BRCH. CIR. AMPACITY 208/230/1/60 24.9 BR. CIR. PROT. RTG. - MAX. (AMPS) 45 COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLED START COMPONENTS INSULATION/SOUND BLANKET COMPRESSOR HEAT SCROLL 1 - 1 208/230/1/60 18.1 - 112 NO NO NO AIR INLETS LOUVERED PANELS ALLOW 12" MINIMUM CLEARANCE OUTDOOR FAN/MOTOR DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. NOTE: GRILL APPEARANCE MAY VARY. VOLTS/PH/HZ F.L. AMPS CONTROL WIRING 7/8" (22.2mm) OUTDOOR COIL -- TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) ACCESS VALVE FOR LOW PRESSURE TUBE SIZE (IN.) NOTE: ONLY ADOPTED BY HEAT PUMP, CAN BE USED FOR MEASURING PRESSURE AFTER SWITCHOVER VALVE-SUCTION TO COMPRESSOR OR REFRIGERANT CHARGE. REFRIGERANT LBS. -- R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ. CHARGING SPECIFICATION PROPELLER/ECM 23-5/8-1 EXTERNAL - 10 3600 1 - 1/3 980 208/230/1/60 2.2 PLATE FIN 2 - 21 18.4 3/16 8 LBS. - 1 OZ. YES 7/8 3/8 SERVICE SUCTION LINE CONNECTION FITTING SUPERHEAT DIMENSIONS CRATED (IN.) 9º F WX H X D 30-1/5×38-1/5×30-1/5 WEIGHT SHIPPING (LBS.) 218 NET (LBS.) 191 NOTE: All dimensions are in mm/inches. Model J4AC5042E1000AA H 843(33-3/16) W 740(29-1/8) L 740(29-1/8) LIQUID VALVE SIZE 3/8 GAS VALVE SIZE 7/8 Mechanical Specification Options General The J4AC50 is fully charged from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application. Optional accessories Liquid line drier -- It is used to filter out impurities and water in the system, ensures system clean and dry. Casing Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weatherresistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500hours salt spray tested. Refrigerant Controls Refrigeration system controls include condenserfan, compressor contactor. Compressor Features include low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels. Literature Order Numbe r File Numbe r Supersede s Stocking Locatio n SS-PRC007-EN -- SS-PRC007-EN 2/0 2 PI Louisville & Webb/MasonHouston OXBOX has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. BX-PRQ-J4AC5042E1000A-1AAcrobat Distiller 9.4.2 (Windows)