About the Manual This manual contains important instructions for the HERF-DCU-4G and must be read in its entirety before installing or commissioning the equipment. For safety, only qualified technician, who has received training or has demonstrated skills can install and maintain this HERF-DCU-4G under the guide of this document. Other Information Product information is subject to change without notice. User manual will be updated frequently, please refer to ESTAR official website at https://estarenergy.com /for the latest version.

info@estarpower.com www.estarenergy.com
Table of Contents
Table of Contents ........................................................................................................................ 3 1. Terminals Introduction ........................................................................................................... 4 2. Introduction to product software functions ....................................................................... 7 3. Installation ............................................................................................................................. 17 4.Technical parameters............................................................................................................. 18

1. Terminals Introduction
1.1 About DCU-4G

info@estarpower.com www.estarenergy.com

LED1DCU-4G working condition light LED2DCU-4G communicating with the platform indicator light LED3DCU-4G communicating with the microinverter indicator light : SIM Port; Ethernet Port DRM Port RS485 Port DC 5V Input Port AP Button Reset Button. Specific functions of each port see Section 1.3 and Section 1.5.

info@estarpower.com www.estarenergy.com
1.2 Communication mode
Adopt the 2.4G wireless scheme with the HERF-DCU-4G communication; Adopt the network cable and 4G coexistence scheme for the communication with the monitoring platform.
1.3 Peripheral interface
The peripheral interface includes RS485 interface, DRM, LED indicator light, Reset button,SIM and AP button. The functions of each interface are briefly described as follows
Ethernet: Use network cables for DCU-4G distribution network. RS485This interface has two functions, one is to prevent reverse flow, the other is to meet the needs of remote scheduling in Europe (Integrated Sunspec Modbus protocol). DRMMeet the DRM power dispatch requirements in Australia. LEDThere are three LED indicators that represent the DCU-4G and platform communication, DCU-4G and microinverter communication, and DCU-4G working status. ResetResets the associated network configuration for the communication with the platform. APLong press 3S to change to AP mode. SIM:Insert a SIM card to use 4G capabilities. RTCAfter the power outage, power up within 7 days, keep the time.
1.4 Power supply mode
This product uses 5V power supply, external power supply adapter

info@estarpower.com www.estarenergy.com

1.5 Indicator light description

This product has 3 LED indicators, respectively representing the DCU-4G status indication, DCU-4G and platform communication, DCU-4G and microinverter communication, as described in the table below

Start / firmware upgrade

The three-lights flash every 0.5 seconds

Machine start

The three-lights flash every 1 second

Firmware update

Three lights flashing at the same time, 0.2 seconds on, Reset success

0.8 seconds out

DCU-4G Status indicator light green Often bright Light flash 0.5s+0.5s Often off

Electrify DCU-4G Work failure Unelectrified

DCU-4G and platform communication green

Often bright

The connection platform is normal

Light flash 0.5s+0.5s

Wait for / try to connect to the network

Light flash slowly1s+1s

Not connected to the monitoring platform

Light flash 0.5s +1.5s

AP mode

DCU-4G and microinverter communication green

Often bright

Communication is normal

Light flash 0.5s+0.5s

There are microinverter not on the communication

Light flash1s+1s

All microinverter are not communicated on

Light flash 0.5s+1.5s

DCU-4G unconfigured microinverter ID

info@estarpower.com www.estarenergy.com
2. Introduction to product software functions
2.1 APP download and installation
1) Scan the following QR code by using the mobile QR code function to download and install the HERF APP(for end userOR HERF PRO APP(for dealer. You can also search for the HERF OR HERF PRO app in the Apple store or the Google paly for download and installation.

HERF

HERF PRO

2) Choose the way DCU-4G connect to the Internet: WIFI OR Ethernet.

2.2 Microinverter data and information upload

At the data level, the data is uploaded in units of Micro-inverter. 1Network disconnection storage data for a week 2Upload time interval is standard with 15 minutes. In addition, the RS485 port only supports Zero-export, Sunspec Modbus protocol functions.

info@estarpower.com www.estarenergy.com
2.3 Station building and monitoring
If you are a new dealer with ESTAR, please apply for a dealer account from ESTAR in advance. (If you are an end user, please apply for a user account from your distributor.
APP:
1) Open the HERF PRO App and log in with your dealer account and password. 2) Set up the DCU-4G connection on your mobile phone, Power on is STA, long press 3S to change to AP mode
3) Select the "Station" tab on the bottom, and then select "" on the right top side of the page to add station. Complete the information filling and user account creation according to the prompts.

Web:
1Login 1Apply for account number 2System requirements Browser: Recommend Google Browser; Screen resolution: Recommended 1920 * 1080, support 1366 * 768. 3Login address https://monitor.estarpower.com 4Login interface

info@estarpower.com www.estarenergy.com

info@estarpower.com www.estarenergy.com
2Construction of power station
1 Click create Plant

info@estarpower.com www.estarenergy.com
2 Enter the name of the power station 3 Select power station types: household, industrial and commercial, large ground power stations; 4 Select an installer or a distributor 5 Input system capacity 6 Select the address of the power station
3Create an owner account 1) When the power station is successfully built in the last step, it will jump to the following interface and click Create Owner;

info@estarpower.com www.estarenergy.com
2Enter the account, password, and full name that you want to create, and click Confirm to determine. 3Add equipment

info@estarpower.com www.estarenergy.com
1get into Add Device/Layoutclick Edit
2Enter the DCU-4G and the SN for the microinverter. 5Layout project
1Select the way of the component arrangement

info@estarpower.com www.estarenergy.com
2Confirm the array name of the component, component layout mode, azimuth, and inclination.
3Select Upload installation Map.

info@estarpower.com www.estarenergy.com
6setting 1Zero-export setting Select Enable Export Management,select Grid type, select electricity meter position.
2Power station setting Monetary unit and electricity price setting, advanced setting, network setting.

info@estarpower.com www.estarenergy.com
2.4 Zero-export function
1Only support the new five kinds Chint electricity meters: DDSU 100A, DTSU 666-2 100A, DTSU666-2 250A,DTSU 666-3 100A, DTSU666-3 250A, only support the grid side, address default 001
2Only support the general control mode, can not be carried electrical separation; 3It can support the three-phase 230 / 400v,single-phase 220v ,split-phase 120/240v power grid.

info@estarpower.com www.estarenergy.com
3. Installation
When installing a DCU-4G with a wall-mounted bracket, select a cool, dry indoor position, fit the wall installed by the DCU-4G, using two gypsum board screws or wall anchors, align and slide the DCU-4G to the mounting screw.

info@estarpower.com www.estarenergy.com

4.Technical parameters

Model

DCU-4G

Communication to Microinverter1

Type

Wireless_2.4G

Maximum distance (open space)

200m

Max. number of connected microinverter

25

Communication to Cloud

Signal

4G/Ethernet

Sample rate

Per 15 minutes

Communication to Meter

Signal

RS485

Maximum distance (RS485 cable)

500m

Interaction

LED

LED Indicator * 3

APP

Local APP

Power Supply (Adapter)

Type

External adapter

Adapter input voltage/frequency

100 to 240 V AC / 50 or 60Hz

Adapter output voltage/current

5V / 2A

Power consumption

2.5W (typical), 5W (maximum)

info@estarpower.com www.estarenergy.com

Mechanical Data

Ambient temperature ()

-20°C to 50°C

Dimensions(W×H×D mm)

142×87×28.5

Weight

0.20 kg

Installation options

Wall mounting / Desktop mounting

Features

Compliance

CE,FCC

*If the DCU-4G installation location is inside the metal box or under the metal/concrete roof, extended antenna will be suggested.

FCC Statement Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment .This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help.



References

Adobe PDF Library 23.8.246