Instructions for NATIONAL INSTRUMENTS models including: PXIe-6396, PXI Multifunction Input or Output Module, PXIe-6396 PXI Multifunction Input or Output Module, Multifunction Input or Output Module, Input or Output Module, Output Module, Module
PXIe-6396 National Instruments PXI Multifunction I/O Module | Apex Waves
File Info : application/pdf, 5 Pages, 1.45MB
DocumentDocumentPXIe-6396 SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION PXIe-6396 8 AI (18-Bit, 14 MS/s/ch), 2 AO, 24 DIO, PXI Multifunction I/O Module Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Icons · --Notice--Take precautions to avoid data loss, loss of signal integrity, degradation of performance, or damage to the model. · --Caution--Take precautions to avoid injury. Consult the model documentation for cautionary statements when you see this icon printed on the model. Cautionary statements are localized into French for compliance with Canadian requirements. Safety Caution Observe all instructions and cautions in the user documentation. Using the model in a manner not specified can damage the model and compromise the built-in safety protection. Return damaged models to NI for repair. Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation utilisateur. L'utilisation d'un modèle de toute autre façon que celle spécifiée risque de l'endommager et de compromettre la protection de sécurité intégrée. Renvoyez les modèles endommagés à NI pour réparation. Maximum Working Voltage Maximum working voltage refers to the signal voltage plus the common-mode voltage. Channel to earth 11 V, Measurement Category I Caution Do not connect the PXIe-6396 to signals or use for measurements within Measurement Categories II, III, or IV. Attention Ne connectez pas le PXIe-6396 à des signaux et ne l'utilisez pas pour effectuer des mesures dans les catégories de mesure II, III ou IV. Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are for other circuits not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. Safety Compliance Standards This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: · IEC 61010-1, EN 61010-1 · UL 61010-1, CSA C22.2 No. 61010-1 Note For UL and other safety certifications, refer to the product label or the Product Certifications and Declarations section. EMC Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by NI could void your authority to operate it under your local regulatory rules. EMC Notices Refer to the following notices for cables, accessories, and prevention measures necessary to ensure the specified EMC performance. Notice Changes or modifications to the product not expressly approved by NI could void your authority to operate the product under your local regulatory rules. Notice Operate this product only with shielded cables and accessories. Electromagnetic Compatibility Standards This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: · EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity · EN 55011 (CISPR 11): Group 1, Class A emissions · AS/NZS CISPR 11: Group 1, Class A emissions · FCC 47 CFR Part 15B: Class A emissions · ICES-003: Class A emissions Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intended for use only in heavy-industrial locations. Notice For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section. Environmental Guidelines Notice This model is intended for use in indoor applications only. Environmental Characteristics Temperature and Humidity Temperature Operating Storage Humidity Operating Storage Pollution Degree Maximum altitude 0 °C to 55 °C -40 °C to 71 °C 10% to 90% RH, noncondensing 5% to 95% RH, noncondensing 2 2,000 m (800 mbar) (at 25 °C ambient temperature) Shock and Vibration Random vibration Operating Non-operating Operating shock 5 Hz to 500 Hz, 0.3 g RMS 5 Hz to 500 Hz, 2.4 g RMS 30 g, half-sine, 11 ms pulse Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Commitment to the Environment web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee. 2 | ni.com | PXIe-6396 Safety, Environmental, and Regulatory Information RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china(For information about China RoHS compliance, go to ni.com/environment/ rohs_china.) Environmental Standards This product meets the requirements of the following environmental standards for electrical equipment. · IEC 60068-2-1 Cold · IEC 60068-2-2 Dry heat · IEC 60068-2-78 Damp heat (steady state) · IEC 60068-2-64 Random operating vibration · IEC 60068-2-27 Operating shock · MIL-PRF-28800F Low temperature limits for operation Class 3, for storage Class 3 High temperature limits for operation Class 2, for storage Class 3 Random vibration for non-operating Class 3 Shock for operating Class 2 Note To verify marine approval certification for a product, refer to the product label or visit ni.com/certification and search for the certificate. Power Requirements Caution The protection provided by the device can be impaired if the device is used in a manner not described in the X Series User Manual. +3.3 V +12 V 6 W 30 W Physical Characteristics Printed circuit board dimensions Weight I/O connectors Module connector Cable connector Standard 3U PXI 294 g (10.4 oz) 68-Pos Right Angle PCB-Mount VHDCI (Receptacle) 68-Pos Offset IDC Cable Connector (Plug) (SHC68-*) Note For more information about the connectors used for DAQ devices, refer to the document, NI DAQ Device Custom Cables, Replacement Connectors, and Screws, by going to ni.com/info and entering the Info Code rdspmb. Maintenance Clean the hardware with a soft, nonmetallic brush. Make sure that the hardware is completely dry and free from contaminants before returning it to service. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: · 2014/35/EU; Low-Voltage Directive (safety) · 2014/30/EU; Electromagnetic Compatibility Directive (EMC) · 2011/65/EU; Restriction of Hazardous Substances (RoHS) Export Compliance This model is subject to control under the U.S. Export Administration Regulations (15 CFR Part 730 et. seq.) administered by the U.S. Department of Commerce's Bureau of Industry and Security (BIS) (www.bis.doc.gov) and other applicable U.S. export control laws and sanctions regulations. This model may also be subject to additional license requirements of other countries' regulations. Additionally, this model may also require export licensing before being returned to NI. The issuance of a Return Material Authorization (RMA) by NI does not constitute export authorization. The user must comply with all applicable export laws prior to exporting or re-exporting this model. See ni.com/legal/exportcompliance for more information and to request relevant import classification codes (e.g. HTS), export classification codes (e.g. ECCN), and other import/ export data. PXIe-6396 Safety, Environmental, and Regulatory Information | © National Instruments | 3 Product Certifications and Declarations Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link. Additional Resources Visit ni.com/manuals for more information about your model, including specifications, pinouts, and instructions for connecting, installing, and configuring your system. Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for information about the services NI offers. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information. Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/ legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2019 National Instruments. All rights reserved. 377254B-01 April 29, 2019