This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. • Refer to Service Manual RS6300014 (Horizontal) for installation, operation, and
Goodman Gpg1436 Install › Url: https://hvacdirect.com/hvac/pdf/GPC14-Tech
TECHNICAL MANUAL *PC 14 SEER R-410A Package Air Conditioners with R-410A · Refer to Service Manual RS6300014 (Horizontal) for installation, operation, and troubleshooting information. · All safety information must be followed as provided in the Service Manual. · Refer to the appropriate Parts Catalog for part number information. · Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. Copyright © 2009 - 2014 Goodman Manufacturing Company, L.P. RT6322013 September 2014 PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. G P C 14 24 H 4 1 A A BRAND: G: Goodman® Brand A: Amana® Brand PRODUCT FAMILY: C: Cooling PRODUCT TYPE: Package Unit PRODUCT SERIES: SEER Rating VOLTAGE: 1: 208-230v 1ph/60Hz MINOR REVISION: A: Initial Release REFRIGERANT : 4: R-410A CONFIGURATION: H: Horizontal MAJOR REVISION: A: Initial Release NOMINAL CAPACITY 24: 24,000 BTUH 30: 30,000 BTUH 36: 36,000 BTUH 42: 42,000 BTUH 48: 48,000 BTUH 60: 60,000 BTUH WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. WARNING Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. 2 WARNING Installation and repair of this unit should be performed ONLY by indi- viduals meeting (at a minimum) the requirements of an "entry level technician" as specified by the Air-Condition- ing, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death. PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GPC1424H41AB GPC1430H41AB GPC1436H41AB GPC1442H41AB GPC1448H41AB GPC1424H41B* GPC1430H41B* GPC1436H41B* GPC1442H41B* GPC1448H41B* GPC1460H41B* GPC1424H41C* GPC1430H41C* GPC1436H41C* GPC1442H41C* GPC1448H41C* GPC1460H41C* GPC1424H41D* APC1424H41D* *PC1430H41D* *PC1436H41D* *PC1442H41D* *PC1448H41D* *PC1460H41D* GPC1424H41E* APC1424H41E* *PC1430H41E* *PC1442H41E* *PC1448H41E* *PC1460H41E* WARNING The United States Environmental Protection Agency ("EPA") has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. WARNING Do not connect or use any device that is not design certified by Good- man for use with this unit. Serious property damage, personal injury, reduced unit perfor- mance and/or hazardous conditions may result from the use of such non-approved devices. WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. 3 PRODUCT DESIGN *PC14 Package Cooling Units are designed for outdoor installations only in either residential or light commercial applications. The connecting ductwork (Supply and Return) can be connected for either horizontal or vertical airflow. In the vertical application a matching Roof Curb is recommended. A return air filter must be installed behind the return air grille(s) or provision must be made for a filter in an accessible location within the return air duct. The minimum filter area should not be less than those sizes listed in the Specification Section. Under no circumstances should the unit be operated without return air filters. A 3/4" PVC pipe is provided for removal of condensate water from the indoor coil In order to provide proper condensate flow, a drain trap is supplied and shipped loose inside the unit for field installation. (Do not reduce the drain line size.) Refrigerant flow control is achieved by use of restrictor orifices. *PC14 units use the FasTest Access Fitting System with a saddle that is either soldered to the suction and liquid lines or is fastened with a locking nut to the access fitting box (core) and then screwed into the saddle. Do not remove the core from the saddle until the refrigerant charge has been removed. Failure to do so could result in property damage or personal injury. The single phase units use permanent split capacitor (PSC) design compressors. Starting components are therefore not required for these units. A low microfarad run capacitor assists the compressor to start and remains in the circuit during operation. All *PC14 units have EEM indoor blower motors that are energized by a 24V signal from the thermostat and are constant torque motors with very low power consumption. The EEM features an integral control module. Air for condensing (cooling cycle) is drawn through the outdoor coil by a propeller fan, and is discharged vertically out the top of the unit. The outdoor coil is designed for .0 static. No additional restriction (ductwork) shall be applied. Conditioned air is drawn through the filter(s), field installed, across the coil and back into the conditioned space by the indoor blower. GPC1424-60H41AB models use Copeland Scroll Compressors. There are a number of design characteristics which are different from the traditional reciprocating compressor. - Due to their design Scroll Compressors are inherently more tolerant of liquid refrigerant. NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued floodback or flooded start conditions may wash oil from the bearing surfaces causing premature bearing failure. - Scroll Compressors use white oil which is compatible with 3GS oil which may be used if additional oil is required. - Operating pressures and amp draws may differ from standard reciprocating compressors. This information may be found in the "Cooling Performance Data" section. Location and Clearances NOTE: To ensure proper condensate drainage, unit must be installed in a level position. 10" 36" WALL UNIT 36" 36" Outside Slab Installation - Horizontal (H) Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency. 36" UNIT PLENUM 24" PLATFORM CURB 36" Rooftop Installation - Horizontal (H) 4 PRODUCT DESIGN In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top installations), the installer must provide service platform for service person with rails or guards in accordance with local codes or ordinances or in their absence with the latest edition of the Uniform Mechanical Code Section 305. NOTE: Unit can also use roof curb. WARNING TO PREVENT POSSIBLE PROPERTY DAMAGE, THE UNIT SHOULD REMAIN IN AN UPRIGHT POSITION DURING ALL RIGGING AND MOVING OPERATIONS. TO FACILITATE LIFTING AND MOVING IF A CRANE IS USED, PLACE THE UNIT IN AN ADEQUATE CABLE SLING. Refer to Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. 5 PRODUCT DIMENSIONS A *PC14[24-60]H41** BACK VIEW (DUCT OPENINGS) B *PC14[24-60]H41A*/B*/C*/D* *PC14[24-60]H41E* Chassis Model A B Chassis Model A B *PC1424 22 30 Small *PC1430 22 30 *PC1436 24 35 Medium *PC1442 24 35 *PC1424 22 30 *PC1430 22 30 Small *PC1436 22 30 *PC1442 22 30 *PC1448 24 38¾ *PC1448 24 35 Large Medium *PC1460 24 38¾ *PC1460 24 35 Dimensions in inches Dimensions in inches 6 PRODUCT DESIGN *PC14[24-60]H41** HKR ELECTRICAL DATA Model and Heat Kit Usage *PC1424H41* HKR/P05*,C* HKR08*,C* HKR/P10*,C* *PC1430H41* HKR/P05*,C* HKR08*,C* HKR/P10*,C* HKR/P15*,C* *PC1436H41* HKR/P05*,C* HKR08*,C* HKR/P10*,C* HKR/P15*,C* *PC1442H41* HKR/P05*,C* HKR08*,C* HKR/P10*,C* HKR/P15*,C* HKR/P20*,C* *PC1448H41* HKR/P05*,C* HKR08*,C* HKR/P10*,C* HKR/P15*,C* HKR/P20*,C* *PC1460H41* HKR/P05*,C* HKR08*,C* HKR/P10*,C* HKR/P15*,C* HKR/P20*,C* Circuit #1 Minimum Circuit Ampacity at 208 / 240V Maximum Overcurrent Protection (amps) at 208 / 240V -- 24 / 27 30 / 30 33 / 38 40 / 40 45 / 51 60 / 60 -- 24 / 27 30 / 30 34 / 39 40 / 40 45 / 52 60 / 60 45 / 52 60 / 60 -- 24 / 27 30 / 30 34 / 39 40 / 40 45 / 52 60 / 60 45 / 52 60 / 60 -- 25 / 27 30 / 30 34 / 39 40 / 40 46 / 52 60 / 60 46 / 52 60 / 60 46 / 52 60 / 60 -- 25 / 28 30 / 30 34 / 40 40 / 40 46 / 53 60 / 60 46 / 52 60 / 60 46 / 52 60 / 60 -- 26 / 30 30 / 30 36 / 40 40 / 40 48 / 54 60 / 60 48 / 54 60 / 60 48 / 54 60 / 60 Circuit #2 Minimum Circuit Ampacity at 208 / 240V Maximum Overcurrent Protection (amps) at 208 / 240V -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 22 / 25 30 / 30 -- -- -- -- -- -- -- -- 22 / 25 30 / 30 -- -- -- -- -- -- -- -- 22 / 25 30 / 30 43 / 49 60 / 60 -- -- -- -- -- -- -- -- 22 / 25 30 / 30 43 / 49 60 / 60 -- -- -- -- -- -- -- -- 22 / 25 30 / 30 43 / 49 60 / 60 IMPORTANT NOTE: A separate power supply is required for the HKR heater kit. Actual kW & BTU at 240V -4.75 / 16,200 7.0 / 23,800 9.5 / 32,400 -4.75 / 16,200 7.0 / 23,800 9.5 / 32,400 14.25 / 48,600 -4.75 / 16,200 7.0 / 23,800 9.5 / 32,400 14.25 / 48,600 -4.75 / 16,200 7.0 / 23,800 9.5 / 32,400 14.25 / 48,600 19.5 / 66,500 -4.75 / 16,200 7.0 / 23,800 9.5 / 32,400 14.25 / 48,600 19.5 / 66,500 -4.75 / 16,200 7.0 / 23,800 9.5 / 32,400 14.25 / 48,600 19.5 / 66,500 WARNING All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during refrigeration cycle. 7 ACCESSORIES *PC14[24-60]H41** Part Number OT18-60A OT/EHR18-60 HKR/P PCCP101-103 PCP101-103 PCP101-103R8 PCEC101-103 PCEH101-103 PCMD101-103 PCMDM101-103 GPHMD101-103 SQRPCH101 SQRPCH102-103 SQRPC101 SQRPC102-103 PCFR101-103 PCEF101-103 CDK36 CDK36515 CDK36530 CDK36535 CDK4872 CDK4872515 CDK4872530 CDK4872535 SPK30-60 ACCESSORIES - *PC/*PH****H UNITS Description Outdoor Thermostat Kit w/Lockout Stat Emergency Heat Relay Kit Electric Heat Kit Roof Curb Downflow Plenum Kit Downflow Plenum Kit w/ R-8 Insulation Downflow Economizer for GPC-(H) A/C - To Be Used With PCP101-103 Downflow Economizer for GPH-(H) Heat Pump - To Be Used With PCP101-103 Manual Damper - To Be Used With PCP101-103 Motorized Damper - To Be Used With PCP101-103 Manual Damper for Horizontal Applications Square to Round Adapters 16"&14" Square to Round Adapters 18"&14" Square to Round Adapter - For Use With PCCP101-103 Curb 16" Rounds Square to Round Adapter For Use With PCCP101-103 Curb 18" Rounds External Horizontal Filter Rack Elbow & Flashing w/ R-8 Liner Flush Mount Concentric Duct Kit Flush Mount Concentric Duct Kit w/ Filter Step Down Concentric Duct Kit Step Down Concentric Duct Kit w/ Filter Flush Mount Concentric Duct Kit Flush Mount Concentric Duct Kit w/ Filter Step Down Concentric Duct Kit Step Down Concentric Duct Kit w/ Filter Single Point Wiring Kit 8 BLOWER PERFORMANCE DATA Dry Coil Data GPC1442H41A*/ B* GPC1436H41A*/ B* GPC14 30 H41A*/ B* GPC14 24 H41A*/ B* M odel Spee d T1 T2 ,T3 T4, T5 T1 T2 ,T3 T4, T5 T1 T2 ,T3 T4, T5 T1 T2 ,T3 T4, T5 T1 T2 ,T3 T4, T5 T1 , T 2, T3 T4, T5 V ol ts CFM 23 0 WA TTS CFM 23 0 WA TTS 23 0 C FM WA TTS CFM 23 0 WA TTS CFM 23 0 WA TTS CFM 23 0 WA TTS CFM 23 0 WA TTS CFM 23 0 WA TTS 23 0 C FM WA TTS CFM 23 0 WA TTS CFM 23 0 WA TTS CFM 23 0 WA TTS CFM 23 0 WA TTS CFM 23 0 WA TTS 23 0 C FM WA TTS CFM 23 0 WA TTS 0 .1 93 4 95 99 0 10 7 10 61 12 6 10 22 11 6 11 03 14 2 12 85 20 5 12 34 14 4 12 87 16 2 13 81 19 5 12 72 16 0 13 57 18 8 15 37 24 4 14 18 24 2 11 75 39 5 18 45 49 0 18 50 36 0 CFM 23 0 WA TTS 20 25 57 5 0. 2 75 9 77 83 7 94 98 9 13 4 92 9 11 4 10 63 15 4 12 40 21 8 11 11 14 0 12 32 17 5 13 25 20 3 11 97 16 8 12 97 20 2 14 78 25 8 13 83 25 8 16 35 42 0 17 90 50 5 17 65 37 5 19 00 59 5 GPC14[24-60]H41A*/B* E. S.P (In. of H 2O) 0.3 0 .4 0 .5 0. 6 755 6 38 5 81 48 9 76 73 83 90 801 7 44 6 96 65 2 105 1 10 1 19 13 3 947 9 25 8 76 - 146 1 58 1 69 - 894 8 29 7 97 74 8 126 1 34 1 44 15 6 1 01 2 9 62 9 37 - 165 1 73 1 85 - 1 20 2 1 163 11 24 10 76 231 2 44 2 57 26 8 1 07 1 1 024 9 33 92 2 152 1 64 1 79 18 3 1 18 6 1 133 10 99 10 53 187 2 01 2 13 22 1 1 27 7 1 233 11 81 11 44 217 2 33 2 47 25 8 1 14 5 1 106 10 55 99 8 183 1 91 2 11 22 0 1 24 4 1 194 11 47 10 99 213 2 28 2 45 25 5 1 43 1 1 386 13 36 12 93 274 2 88 3 03 31 7 1 34 9 1 312 12 75 12 28 273 2 82 2 99 30 8 1 64 5 1 515 15 10 14 50 435 4 45 4 55 46 5 1 71 5 1 685 15 90 15 80 520 5 35 5 50 56 0 1 71 0 1 625 15 75 15 35 380 3 90 4 00 41 0 1 84 0 1 780 17 25 16 50 620 6 30 6 45 65 5 0.7 - 601 142 695 168 1 04 6 280 947 230 1 04 9 267 1 25 3 329 1 17 8 320 1 43 0 470 1 53 0 570 1 49 5 420 1 62 0 660 0 .8 - 6 43 1 73 1 00 3 2 88 9 06 2 43 1 00 8 2 84 1 20 8 3 41 1 14 1 3 38 1 40 0 4 75 1 50 0 5 75 1 43 5 4 30 1 58 0 6 70 GPC1460H41A*/ B* GPC1448H41A*/B* NOTE S: 1 . D at a sh ow n is dr y co il. W et coil p re ssure dr op is a pp ro x. 2 . 0 .1" H2 O , fo r 2 ro w in do or co il; 0.2 " H 2 O , f or 3 ro w indo or co il; an d 0.3 " H 2O , f or 4 ro w indo or co il. 3 . D at a sh ow n do es n ot includ e filter p re ssur e dr op , a pp ro x. 0 .08 " H2O . 4 . R ed uce a ir flo w b y 2 % fo r 20 8V op er atio n. 9 BLOWER PERFORMANCE DATA Dry Coil Data GPC1460H41CA GPC1448H41CA GPC1442H41CA GPC1436H41CA GPC1430H41CA GPC1424H41CA Model Speed T1 T2,T3 T4, T5 T1 T2,T3 T4, T5 T1 T2,T3 T4, T5 T1 T2,T3 T4, T5 T1 T2,T3 T4, T5 T1 T2,T3 T4,T5 Volts CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS CFM 230 W A TTS 0.1 922 74 922 74 1069 102 1048 97 1123 123 1244 158 1151 132 1261 131 1376 170 1165 118 1258 150 1511 239 1421 170 1696 287 1859 356 1507 168 1694 296 1965 481 0.2 873 85 873 85 1020 113 993 109 1068 136 1189 170 1097 144 1215 144 1330 182 1122 130 1216 162 1469 251 1367 182 1643 299 1805 368 1459 175 1646 303 1917 489 0.3 823 96 823 96 971 124 939 122 1014 148 1135 183 1042 156 1169 157 1284 195 1080 142 1173 175 1427 263 1314 195 1589 312 1751 381 1410 183 1598 311 1869 496 GPC14[24-60]H41CA E.S.P (In. of H2O) 0.4 0.5 774 724 107 118 774 724 107 118 921 872 135 146 884 829 134 147 959 905 161 173 1080 1026 195 208 988 933 169 181 1123 1076 169 182 1237 1191 207 220 1037 995 154 166 1131 1088 187 199 1384 1342 275 287 1260 1206 208 220 1535 1481 325 337 1698 1644 394 406 1362 1314 191 199 1549 1501 319 327 1821 1773 504 512 0.6 675 129 675 129 822 157 775 159 850 186 971 220 879 194 1030 194 1145 233 953 178 1046 211 1299 299 1152 233 1428 350 1590 419 1266 207 1453 334 1724 520 0.7 626 140 626 140 773 168 720 172 796 198 917 233 824 206 984 207 1099 245 910 190 1004 223 1257 311 1099 246 1374 363 1536 432 1218 214 1405 342 1676 528 0.8 576 151 576 151 724 179 666 184 741 211 862 245 770 219 937 220 1052 258 868 202 961 235 1214 323 1045 258 1320 375 1483 444 1169 222 1357 350 1628 535 10 BLOWER PERFORMANCE DATA *PC14[24-60]H41D*/E* *PC1448H41E* *PC1442H41E* *PC1460H41D*/E* *PC1448H41D* *PC1442H41D* *PC1436H41D* *PC1430HD*/E* *PC1424HD*/E* Model Speed T1 T2 / T3 T4 / T5 T1 T2 / T3 T4 / T5 T1 T2 / T3 T4 / T5 T1 T2 / T3 T4 / T5 T1 T2 / T3 T4 / T5 T1 T2 / T3 T4 / T5 T1 T2 / T3 T4 / T5 T1 T2 / T3 T4 / T5 Volts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 230 CFM Watts 0.1 922 74 922 74 1231 168 1048 97 1123 123 1462 241 1151 132 1261 131 1577 277 1165 118 1258 150 1645 285 1421 170 1696 287 1983 553 1507 168 1694 296 1919 449 1181 146 1410 222 1637 331 1337 179 1711 330 2002 498 0.2 873 85 873 85 1179 180 993 109 1068 136 1409 253 1097 144 1215 144 1525 290 1122 130 1216 162 1602 297 1367 182 1643 299 1928 565 1459 175 1646 303 1870 457 1146 158 1366 236 1605 348 1297 190 1640 341 1935 521 0.3 823 96 823 96 1127 193 939 122 1014 148 1357 266 1042 156 1169 157 1472 302 1080 142 1173 175 1560 309 1314 195 1589 312 1873 578 1410 183 1598 311 1822 465 1112 174 1328 250 1561 361 1218 203 1605 358 1885 516 E.S.P. (In. of H2 O) 0.4 0.5 774 724 107 118 774 724 107 118 1074 1022 205 218 884 829 134 147 959 905 161 173 1305 1252 278 291 988 933 169 181 1123 1076 169 182 1420 1367 314 327 1037 995 154 166 1131 1088 187 199 1517 1475 321 333 1260 1206 208 220 1535 1481 325 337 1818 1763 591 603 1362 1314 191 199 1549 1501 319 327 1774 1726 472 480 1062 1022 182 196 1286 1248 260 273 1527 1484 374 385 1155 1118 210 225 1537 1496 370 377 1827 1767 534 551 0.6 675 129 675 129 969 230 775 159 850 186 1200 303 879 194 1030 194 1315 339 953 178 1046 211 1433 346 1152 233 1428 350 1708 616 1266 207 1453 334 1678 488 977 208 1195 285 1436 392 1088 243 1441 394 1732 567 0.7 626 140 626 140 917 243 720 172 796 198 1147 315 824 206 984 207 1263 352 910 190 1004 223 1390 358 1099 246 1374 363 1652 629 1218 214 1405 342 1629 496 937 218 1155 296 1390 407 1022 249 1397 408 1669 571 0.8 576 151 576 151 865 255 666 184 741 211 1095 328 770 219 937 220 1210 364 868 202 961 235 1348 370 1045 258 1320 375 1597 641 1169 222 1357 350 1581 503 891 227 1115 305 1345 417 989 268 1347 418 1618 574 11 BLOWER PERFORMANCE DATA 12 BTU OUTPUT vs TEMPERATURE RISE CHART 100 TEMPERATURE RISE 600 CFM 90 700 80 800 900 70 1000 1100 1200 60 1400 50 1600 1800 2000 40 2200 2400 CFM 30 FORMULAS BTU OUTPUT = CFM x 1.08 x RISE 20 BTU OUTPUT RISE = 1.08 ÷ CFM 10 30 40 50 60 70 80 90 100 110 120 130 140 150 OUTPUT BTU/HR x 1000 PACKAGE COOLING SPECIFICATIONS GPC14[24-36]H41AB GPC1424H41AB GPC1430H41AB GPC1436H41AB COOLING COOLING CAPACITY, BTUH 24,600 28,400 35,600 CAPACITY SEER / EER 14.5 / 12.1 14.0 / 12.1 14.0 / 12.0 UNIT VOLTAGE (NAMEPLATE) 208-230/1/60 208-230/1/60 208-230/1/60 ELECTRICAL AMPS (TOTAL) 16.1 15.76 20.06 SPECIFICATION MINIMUM CIRCUIT AMPACITY 19.5 19 24.2 MAXIMUM OVERCURRENT PROTECTION (1) 30 30 40 COMPRESSOR TYPE SCROLL SCROLL SCROLL RATED LOAD AMPS 13.5 12.8 16.7 LOCKED ROTOR AMPS 58.3 64 79 CONDENSER HORSEPOWER 1/6 1/6 1/4 FAN MOTOR RPM 815 815 830 FULL LOAD AMPS 1.1 1.1 1.5 LOCKED ROTOR AMPS 1.7 1.7 3.0 CONDENSER FANBLADE DIAMETER (INCHES) / # OF BLADES 22 / 2 22 / 2 22 / 3 CONDENSER FACE AREA - SQ. FT. 12.3 12.3 12.3 COIL NUMBER OF ROWS 1 1 1 FINS PER INCH 26 26 26 EVAPORATOR HORSEPOWER - NO. OF SPEEDS 1/2 - 5 1/2 - 5 1/2 - 5 BLOWER FULL LOAD AMPS 1.5 1.86 1.86 MOTOR LOCKED ROTOR AMPS NA NA NA MOTOR SPEED TAP - COOLING T2 T2 T2 RPM 1050 1050 1050 EVAPORATOR DIAMETER X WIDTH (INCHES) 10 X 8 10 X 8 10 X 8 BLOWER HI EFFICIENCY COOLING CFM 850 1,050 1,200 FAN ONLY COOLING CFM 800 950 1,100 MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 EVAPORATOR FACE AREA - SQ. FT. 5.25 5.25 5.2 COIL NUMBER OF ROWS 3 3 3 GENERAL INFORMATION FINS PER INCH FILTER SIZE - SQ. FT. * DRAIN SIZE (INCHES) 16 20 x 20 x 1 3/4" 16 20 x 25 x 1 3/4" 14 25 x 25 x 1 3/4" EXPANSION DEVICE ORIFICE (0.057) ORIFICE (0.062) ORIFICE (0.068) REFRIGERANT CHARGE R-410A (Oz.) 59 53 65 POWER SUPPLY CONDUIT KNOCKOUT SIZE (IN.) 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 LOW VOLTAGE CONDUIT KNOCKOUT SIZE (IN.) 1/2 1/2 1/2 SHIPPING WEIGHT LBS. 290 290 370 OPERATING WEIGHT LBS. 280 280 360 (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. 13 PACKAGE COOLING SPECIFICATIONS GPC14[42-48]H41AB GPC1442H41AB GPC1448H41AB COOLING CAPACITY, BTUH SEER / EER VOLTAGE (NAMEPLATE) AMPS (TOTAL) MINIMUM CIRCUIT AMPACITY MAXIMUM OVERCURRENT PROTECTION (1) TYPE RATED LOAD AMPS LOCKED ROTOR AMPS HORSEPOWER RPM FULL LOAD AMPS LOCKED ROTOR AMPS BLADE DIAMETER (INCHES) / # OF BLADES FACE AREA - SQ. FT. NUMBER OF ROWS FINS PER INCH HORSEPOWER - NO. OF SPEEDS FULL LOAD AMPS LOCKED ROTOR AMPS MOTOR SPEED TAP - COOLING RPM DIAMETER X WIDTH (INCHES) HI EFFICIENCY COOLING CFM 5 TON NOMINAL COOLING CFM FAN ONLY COOLING CFM MAX EXTERNAL STATIC PRESS ("w.c.) FACE AREA - SQ. FT. NUMBER OF ROWS FINS PER INCH FILTER SIZE - SQ. FT. * DRAIN SIZE (INCHES) EXPANSION DEVICE REFRIGERANT CHARGE R-410A (Oz.) POWER SUPPLY CONDUIT KNOCKOUT SIZE (IN.) LOW VOLTAGE CONDUIT KNOCKOUT SIZE (IN.) SHIPPING WEIGHT LBS. OPERATING WEIGHT LBS. 40,000 46,500 14.2 / 12.0 14.5 / 12.0 208-230/1/60 208-230/1/60 22.2 24.2 26.6 29.1 40 45 SCROLL SCROLL 17.9 19.9 112 109 1/4 1/4 1075 1075 1.4 1.4 2.9 2.9 22 / 4 22 / 4 16.0 19.5 1 1 28 28 1/2 - 5 3/4 - 5 2.9 2.9 NA NA T2 T2 1050 1050 10 x 8 10 x 8 1,300 1,600 NA NA 1,200 1,400 0.5 0.5 6.2 6.2 4 4 14 14 (2) 20 x 20 x 1 (2) 20 x 20 x 1 3/4" 3/4" ORIFICE (0.072) ORIFICE (0.078) 94 90 3/4, 1, 1-1/4 3/4, 1, 1-1/4 1/2 1/2 370 400 360 390 (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. 14 PACKAGE COOLING SPECIFICATIONS GPC14[24-36]H41B*/C* COOLING COOLING CAPACITY, BTUH GPC1424H41 B* 24,600 GPC1424H41 C* 24,600 GPC1430H41 B*/C* 28,400 GPC1436H41 B*/C* 35,600 CAPACITY SEER / EER 14.5 / 12.1 14.5 / 12.1 14.0 / 12.1 14.0 / 12.0 UNIT VOLTAGE (NAMEPLATE) 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 ELECTRICAL AMPS (TOTAL) 16.1 10.3 15.76 20.06 SPECIFICATION MINIMUM CIRCUIT AMPACITY 19.5 12.2 19 24.2 MAXIMUM OVERCURRENT PROTECTION (1) 30 15 30 40 COMPRESSOR TYPE SCROLL ROTARY SCROLL SCROLL RATED LOAD AMPS 13.5 7.7 12.8 16.7 LOCKED ROTOR AMPS 58.3 37 64 79 CONDENSER HORSEPOWER 1/6 1/6 1/6 1/4 FAN MOTOR RPM 815 815 815 830 FULL LOAD AMPS 1.1 1.1 1.1 1.5 LOCKED ROTOR AMPS 1.7 1.7 1.7 3.0 CONDENSER FANBLADE DIAMETER (INCHES) / # OF BLADES 22 / 2 22 / 2 22 / 2 22 / 3 CONDENSER FACE AREA - SQ. FT. 12.3 12.3 12.3 12.3 COIL NUMBER OF ROWS 1 1 1 1 FINS PER INCH 26 26 26 26 EVAPORATOR HORSEPOWER - NO. OF SPEEDS 1/2 - 5 1/2 - 5 1/2 - 5 1/2 - 5 BLOWER FULL LOAD AMPS 1.5 1.5 1.86 1.86 MOTOR LOCKED ROTOR AMPS NA NA NA NA MOTOR SPEED TAP - COOLING T2 T2 T2 T2 RPM 1050 1050 1050 1050 EVAPORATOR DIAMETER X WIDTH (INCHES) 10 X 8 10 X 8 10 X 8 10 X 8 BLOWER HI EFFICIENCY COOLING CFM 850 850 1,050 1,200 FAN ONLY COOLING CFM 800 800 950 1,100 MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 0.5 EVAPORATOR FACE AREA - SQ. FT. 4.66 4.66 5.25 5.25 COIL NUMBER OF ROWS 3 3 3 3 GENERAL INFORMATION FINS PER INCH FILTER SIZE - SQ. FT. * DRAIN SIZE (INCHES) 16 20 x 20 x 1 3/4" 16 20 x 20 x 1 3/4" 16 20 x 25 x 1 3/4" 14 25 x 25 x 1 3/4" EXPANSION DEVICE ORIFICE (0.057) ORIFICE (0.057) ORIFICE (0.062) ORIFICE (0.068) REFRIGERANT CHARGE R-410A (Oz.) 59 60 61 65 POWER SUPPLY CONDUIT KNOCKOUT SIZE (IN.) 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 LOW VOLTAGE CONDUIT KNOCKOUT SIZE (IN.) 1/2 1/2 1/2 1/2 SHIPPING WEIGHT LBS. 310 310 315 330 OPERATING WEIGHT LBS. 305 305 310 315 (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. 15 PACKAGE COOLING SPECIFICATIONS GPC14[42-60]H41B*/C* COOLING COOLING CAPACITY, BTUH CAPACITY SEER / EER UNIT VOLTAGE (NAMEPLATE) ELECTRICAL AMPS (TOTAL) SPECIFICATION MINIMUM CIRCUIT AMPACITY MAXIMUM OVERCURRENT PROTECTION (1) COMPRESSOR TYPE RATED LOAD AMPS LOCKED ROTOR AMPS CONDENSER HORSEPOWER FAN MOTOR RPM FULL LOAD AMPS LOCKED ROTOR AMPS CONDENSER FANBLADE DIAMETER (INCHES) / # OF BLADES CONDENSER FACE AREA - SQ. FT. COIL NUMBER OF ROWS FINS PER INCH EVAPORATOR HORSEPOWER - NO. OF SPEEDS BLOWER FULL LOAD AMPS MOTOR LOCKED ROTOR AMPS MOTOR SPEED TAP - COOLING RPM EVAPORATOR DIAMETER X WIDTH (INCHES) BLOWER HI EFFICIENCY COOLING CFM 5 TON NOMINAL COOLING CFM FAN ONLY COOLING CFM MAX EXTERNAL STATIC PRESS ("w.c.) EVAPORATOR FACE AREA - SQ. FT. COIL NUMBER OF ROWS FINS PER INCH GENERAL FILTER SIZE - SQ. FT. * INFORMATION DRAIN SIZE (INCHES) EXPANSION DEVICE REFRIGERANT CHARGE R-410A (Oz.) POWER SUPPLY CONDUIT KNOCKOUT SIZE (IN.) LOW VOLTAGE CONDUIT KNOCKOUT SIZE (IN.) SHIPPING WEIGHT LBS. OPERATING WEIGHT LBS. GPC1442H41 B*/C* 40,000 14.0 / 12.0 208-230/1/60 22.2 26.6 40 SCROLL 17.9 112 1/4 1075 1.4 2.9 22 / 4 16.0 1 28 1/2 - 5 2.9 NA T2 1050 10 x 8 1,300 NA 1,200 0.5 6.2 4 14 (2) 20 x 20 x 1 3/4" ORIFICE (0.072) 94 3/4, 1, 1-1/4 1/2 360 355 GPC1448H41 B*/C* 46,500 14.0 / 12.0 208-230/1/60 24.2 29.1 45 SCROLL 19.9 109 1/4 1075 1.4 2.9 22 / 4 19.5 1 28 3/4 - 5 2.9 NA T2 1050 10 x 8 1,600 NA 1,400 0.5 6.2 4 14 (2) 20 x 20 x 1 3/4" ORIFICE (0.076) 90 3/4, 1, 1-1/4 1/2 375 370 GPC1460H41 B*/C* 57,500 14.0 / 12.0 208-230/1/60 30.7 37.3 60 SCROLL 26.4 134 1/4 1075 1.4 2.9 22 / 4 17 2 28 3/4 - 5 2.9 NA T2 1050 11 x 8 1,700 1,800 1,700 0.5 7.0 4 14 (2) 20 x 25 x 1 3/4" ORIFICE (0.086) 110 3/4, 1, 1-1/4 1/2 380 375 (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. 16 PACKAGE COOLING SPECIFICATIONS *PC14[24-36]H41D* GPC1424H41D* APC1424H41D* COOLING COOLING CAPACITY, BTUH 24,600 CAPACITY SEER / EER 14.5 / 12.1 UNIT VOLTAGE (NAMEPLATE) 208-230/1/60 ELECTRICAL AMPS (TOTAL) 12.6 SPECIFICATION MINIMUM CIRCUIT AMPACITY 15 MAXIMUM OVERCURRENT PROTECTION (1) 20 COMPRESSOR TYPE ROTARY RATED LOAD AMPS 7.7 LOCKED ROTOR AMPS 37 CONDENSER HORSEPOWER 1/6 FAN MOTOR RPM 815 FULL LOAD AMPS 1.1 LOCKED ROTOR AMPS 1.7 CONDENSER FANBLADE DIAMETER (INCHES) / # OF BLADES 22 / 2 CONDENSER FACE AREA - SQ. FT. 12.3 COIL NUMBER OF ROWS 1 FINS PER INCH 26 EVAPORATOR HORSEPOWER - NO. OF SPEEDS 1/2 - 5 BLOWER FULL LOAD AMPS 3.8 MOTOR LOCKED ROTOR AMPS NA MOTOR SPEED TAP - COOLING T2 RPM 1050 EVAPORATOR DIAMETER X WIDTH (INCHES) 10 X 8 BLOWER HI EFFICIENCY COOLING CFM 850 FAN ONLY COOLING CFM 800 MAXEXTERNAL STATIC PRESS ("w.c.) 0.8 EVAPORATOR FACE AREA - SQ. FT. 4.66 COIL NUMBER OF ROWS 3 GENERAL INFORMATION FINS PER INCH FILTER SIZE - SQ. FT. * DRAIN SIZE (INCHES) 16 20 x 20 x 1 3/4" EXPANSION DEVICE ORIFICE (0.057) REFRIGERANT CHARGE R-410A (Oz.) 60 POWER SUPPLY CONDUIT KNOCKOUT SIZE (IN.) 3/4, 1, 1-1/4 LOW VOLTAGE CONDUIT KNOCKOUT SIZE (IN.) 1/2 SHIPPING WEIGHT LBS. 310 OPERATING WEIGHT LBS. 305 24,600 14.5 / 12.1 208-230/1/60 18.4 22 35 SCROLL 13.5 58.3 1/6 815 1.1 1.7 22 / 2 12.3 1 26 1/2 - 5 3.8 NA T2 1050 10 X 8 850 800 0.8 4.66 3 16 20 x 20 x 1 3/4" ORIFICE (0.057) 60 3/4, 1, 1-1/4 1/2 310 305 *PC1430H41D* 28,400 14.0 / 12.1 208-230/1/60 17.7 21 30 SCROLL 12.8 64 1/6 815 1.1 1.7 22 / 2 12.3 1 26 1/2 - 5 3.8 NA T2 1050 10 X 8 1,050 950 0.8 5.25 3 16 20 x 25 x 1 3/4" ORIFICE (0.062) 61 3/4, 1, 1-1/4 1/2 315 310 *PC1436H41D* 35,600 14.0 / 12.0 208-230/1/60 22 26 40 SCROLL 16.7 79 1/4 830 1.5 3.0 22 / 3 12.3 1 26 1/2 - 5 3.8 NA T2 1050 10 X 8 1,200 1,100 0.8 5.25 3 14 25 x 25 x 1 3/4" ORIFICE (0.068) 65 3/4, 1, 1-1/4 1/2 330 315 (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. 17 PACKAGE COOLING SPECIFICATIONS *PC14[42-60]H41D* *PC1442H41D* *PC1448H41D* *PC1460H41D* COOLING COOLING CAPACITY, BTUH 40,000 46,500 57,500 CAPACITY UNIT ELECTRICAL SEER / EER VOLTAGE (NAMEPLATE) AMPS (TOTAL) 14.0 / 12.0 208-230/1/60 23.1 14.0 / 12.0 208-230/1/60 26.7 14.0 / 12.0 208-230/1/60 33.2 SPECIFICATION COMPRESSOR MINIMUM CIRCUIT AMPACITY MAXIMUM OVERCURRENT PROTECTION (1) TYPE 28 45 SCROLL 32 50 SCROLL 40.0 60 SCROLL RATED LOAD AMPS 17.9 19.9 26.4 CONDENSER LOCKED ROTOR AMPS HORSEPOW ER 112 109 134 1/4 1/4 1/4 FAN MOTOR RPM 1075 1075 1075 FULL LOAD AMPS 1.4 1.4 1.4 LOCKED ROTOR AMPS CONDENSER FAN BLADE DIAMETER (INCHES) / # OF BLADES 2.9 22 / 4 2.9 22 / 4 2.9 22 / 4 CONDENSER FACE AREA - SQ. FT. 16.0 19.5 17 COIL NUMBER OF ROWS FINS PER INCH 1 1 2 28 28 28 EVAPORATOR HORSEPOWER - NO. OF SPEEDS 1/2 - 5 3/4 - 5 3/4 - 5 BLOWER MOTOR FULL LOAD AMPS LOCKED ROTOR AMPS 3.8 5.4 5.4 NA NA NA MOTOR SPEED TAP - COOLING T2 T2 T2 RPM 1050 1050 1050 EVAPORATOR BLOWER DIAMETER X WIDTH (INCHES) HI EFFICIENCY COOLING CFM 10 x 8 1,300 10 x 8 1,600 11 x 8 1,700 5 TON NOMINAL COOLING CFM NA NA 1,800 FAN ONLY COOLING CFM MAX EXTERNAL STATIC PRESS ("w.c.) 1,200 0.5 / 0.8** 1,400 0.5 / 0.8** 1,700 0.5 / 0.8** EVAPORATOR FACE AREA - SQ. FT. 6.2 6.2 7.0 COIL NUMBER OF ROWS 4 4 4 GENERAL INFORMATION FINS PER INCH FILTER SIZE - SQ. FT. * DRAIN SIZE (INCHES) 14 (2) 20 x 20 x 1 3/4" 14 (2) 20 x 20 x 1 3/4" 14 (2) 20 x 25 x 1 3/4" EXPANSION DEVICE REFRIGERANT CHARGE R-410A (Oz.) ORIFICE (0.072) 94 ORIFICE (0.076) 90 ORIFICE (0.086) 110 POWER SUPPLY CONDUIT KNOCKOUT SIZE (IN.) 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 LOW VOLTAGE CONDUIT KNOCKOUT SIZE (IN.) 1/2 1/2 1/2 SHIPPING WEIGHT LBS. OPERATING WEIGHT LBS. 360 375 380 355 370 375 ** When using a 20kW electric heater, unit is rated for 0.5 E.S.P. For all other electric heat sizes as well as units with no heater installed, the max E.S.P is 0.8. (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. 18 PACKAGE COOLING SPECIFICATIONS *PC14[24-36]H41E* GPC1424H41E* APC1424H41E* *PC1430H41E* *PC1436H41E* COOLING COOLING CAPACITY, BTUH 24,600 24,600 28,400 35,600 CAPACITY SEER / EER 14.5 / 12.1 14.5 / 12.1 14.0 / 12.1 14.0 / 12.0 UNIT VOLTAGE (NAMEPLATE) 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 ELECTRICAL AMPS (TOTAL) 12.6 18.4 19 22 SPECIFICATION MINIMUM CIRCUIT AMPACITY 15 22 23 26 MAXIMUM OVERCURRENT PROTECTION (1) 20 35 35 40 COMPRESSOR TYPE ROTARY SCROLL SCROLL SCROLL RATED LOAD AMPS 7.7 13.5 14.1 16.7 LOCKED ROTOR AMPS 37 58.3 64 79 CONDENSER HORSEPOWER 1/6 1/6 1/6 1/4 FAN MOTOR RPM 815 815 815 830 FULL LOAD AMPS 1.1 1.1 1.1 1.5 LOCKED ROTOR AMPS 1.7 1.7 1.7 3.0 CONDENSER FAN BLADE DIAMETER (INCHES) / # OF BLADES 22 / 2 22 / 2 22 / 2 22 / 3 CONDENSER FACE AREA - SQ. FT. 9.3 9.3 9.3 12.3 COIL NUMBER OF ROWS 1 1 1 1 FINS PER INCH 27 27 27 27 EVAPORATOR HORSEPOWER - NO. OF SPEEDS 1/2 - 5 1/2 - 5 1/2 - 5 1/2 - 5 BLOWER FULL LOAD AMPS 3.8 3.8 3.8 3.8 MOTOR LOCKED ROTOR AMPS NA NA NA NA MOTOR SPEED TAP - COOLING T2 T2 T2 T2 RPM 1050 1050 1050 1050 EVAPORATOR DIAMETER X WIDTH (INCHES) 10 X 8 10 X 8 10 X 8 10 X 8 BLOWER HI EFFICIENCY COOLING CFM 850 850 1,050 1,200 FAN ONLY COOLING CFM 800 800 950 1,100 MAX EXTERNAL STATIC PRESS ("w .c.) 0.8 0.8 0.8 0.8 EVAPORATOR FACE AREA - SQ. FT. 5.25 5.25 5.25 5.25 COIL NUMBER OF ROWS 3 3 3 3 FINS PER INCH 14 14 14 14 GENERAL FILTER SIZE - SQ. FT. * 20 x 20 x 1 20 x 20 x 1 20 x 25 x 1 25 x 25 x 1 INFORMATION DRAIN SIZE (INCHES) 3/4" 3/4" 3/4" 3/4" EXPANSION DEVICE ORIFICE (0.055) ORIFICE (0.059) ORIFICE (0.063) ORIFICE (0.068) REFRIGERANT CHARGE R-410A (Oz.) 51 54 46 65 POWER SUPPLY CONDUIT KNOCKOUT SIZE (IN.) 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 LOW VOLTAGE CONDUIT KNOCKOUT SIZE (IN.) 1/2 1/2 1/2 1/2 SHIPPING WEIGHT LBS. 305 305 310 330 OPERATING WEIGHT LBS. 300 300 305 315 (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. 19 PACKAGE COOLING SPECIFICATIONS *PC14[42-60]H41E* *PC1442H41E* *PC1448H41E* *PC1460H41E* COOLING COOLING CAPACITY, BTUH 40,000 46,500 57,500 CAPACITY SEER / EER 14.0 / 12.0 14.0 / 12.0 14.0 / 11.5 UNIT VOLTAGE (NAMEPLATE) 208-230/1/60 208-230/1/60 208-230/1/60 ELECTRICAL AMPS (TOTAL) 23.1 26.7 33.2 SPECIFICATION MINIMUM CIRCUIT AMPACITY 28 32 40.0 MAXIMUM OVERCURRENT PROTECTION (1) 45 50 60 COMPRESSOR TYPE SCROLL SCROLL SCROLL RATED LOAD AMPS 17.9 19.9 26.4 LOCKED ROTOR AMPS 112 109 134 CONDENSER HORSEPOWER 1/4 1/4 1/4 FAN MOTOR RPM 1075 1075 1075 FULL LOAD AMPS 1.4 1.4 1.4 LOCKED ROTOR AMPS 2.9 2.9 2.9 CONDENSER FAN BLADE DIAMETER (INCHES) / # OF BLADES 22 / 4 22 / 4 22 / 4 CONDENSER FACE AREA - SQ. FT. 12.3 16.0 15 COIL NUMBER OF ROWS 1 1 2 FINS PER INCH 27 27 27 EVAPORATOR HORSEPOWER - NO. OF SPEEDS 1/2 - 5 3/4 - 5 3/4 - 5 BLOW ER FULL LOAD AMPS 3.8 5.4 5.4 MOTOR LOCKED ROTOR AMPS NA NA NA MOTOR SPEED TAP - COOLING T2 T2 T2 RPM 1050 1050 1050 EVAPORATOR DIAMETER X WIDTH (INCHES) 10 x 8 10 x 8 11 x 8 BLOW ER HI EFFICIENCY COOLING CFM 1,300 1,600 1,700 5 TON NOMINAL COOLING CFM NA NA 1,800 FAN ONLY COOLING CFM 1,200 1,400 1,700 MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 / 0.8** 0.5 / 0.8** 0.5 / 0.8** EVAPORATOR FACE AREA - SQ. FT. 5.25 6.2 6.2 COIL NUMBER OF ROWS 4 4 4 FINS PER INCH 14 14 14 GENERAL FILTER SIZE - SQ. FT. * (2) 20 x 20 x 1 (2) 20 x 20 x 1 (2) 20 x 25 x 1 INFORMATION DRAIN SIZE (INCHES) 3/4" 3/4" 3/4" EXPANSION DEVICE ORIFICE (0.076) ORIFICE (0.076) ORIFICE (0.086) REFRIGERANT CHARGE R-410A (Oz.) 70 85 103 POWER SUPPLY CONDUIT KNOCKOUT SIZE (IN.) 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 LOW VOLTAGE CONDUIT KNOCKOUT SIZE (IN.) 1/2 1/2 1/2 SHIPPING WEIGHT LBS. 355 370 375 OPERATING WEIGHT LBS. 350 365 370 ** When using a 20kW electric heater, unit is rated for 0.5 E.S.P. For all other electric heat sizes as well as units with no heater installed, the max E.S.P is 0.8. (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. 20 COOLING PERFORMANCE DATA MOD EL: *PC1424H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 9 ± 2°F @ the liquid acce s s fitting conne ction AHRI 95 te s t conditions . De s ign Supe r he at 5 ± 2°F @ the com pr e s s or s uction acce s s fitting conne ction. Outdoor Am bie nt Te m pe r ature 65 75 85 95 105 115 Ente ring Indoor We t Bulb Te m pe ratur e Air flow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 24.1 25.0 27.4 - 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5 - 21.3 22.1 24.2 - 19.7 20.5 22.4 - S/T 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.85 0.71 0.49 - Delta T 17 15 11 - 17 15 11 - 17 15 11 - 18 15 12 - 17 15 11 - 16 14 11 - 955 KW 1.57 1.60 1.66 - 1.70 1.73 1.79 - 1.81 1.85 1.91 - 1.91 1.95 2.02 - 1.99 2.04 2.11 - 2.06 2.11 2.19 - A MPS 6.6 6.8 7.0 - 7.1 7.3 7.5 - 7.7 7.9 8.1 - 8.2 8.4 8.7 - 8.7 8.9 9.2 - 9.2 9.4 9.7 - HI PR 233 251 265 - 262 282 298 - 298 321 338 - 339 365 386 - 382 411 434 - 422 454 479 - LO PR 111 118 129 - 118 125 137 - 122 130 142 - 128 137 149 - 135 143 156 - 139 148 162 - MBh 23.4 24.3 26.6 - 22.9 23.7 26.0 - 22.3 23.1 25.3 - 21.8 22.6 24.7 - 20.7 21.4 23.5 - 19.2 19.9 21.8 - S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 - Delta T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 - 70 850 KW 1.56 1.59 1.64 - 1.68 1.72 1.78 - 1.79 1.83 1.90 - 1.89 1.93 2.00 - 1.97 2.02 2.09 - 2.05 2.09 2.17 - A MPS 6.6 6.7 6.9 - 7.1 7.2 7.5 - 7.7 7.8 8.1 - 8.1 8.3 8.6 - 8.6 8.8 9.1 - 9.1 9.3 9.6 - HI PR 231 249 263 - 259 279 295 - 295 317 335 - 336 361 382 - 378 407 429 - 418 449 474 - LO PR 110 117 128 - 116 124 135 - 121 129 141 - 127 135 148 - 133 142 155 - 138 147 160 - MBh 21.6 22.4 24.5 - 21.1 21.9 24.0 - 20.6 21.3 23.4 - 20.1 20.8 22.8 - 19.1 19.8 21.7 - 17.7 18.3 20.1 - S/T 0.68 0.57 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.78 0.66 0.45 - Delta T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 - 745 KW 1.52 1.55 1.60 - 1.64 1.68 1.73 - 1.75 1.79 1.85 - 1.84 1.88 1.95 - 1.92 1.97 2.03 - 1.99 2.04 2.11 - A MPS 6.4 6.6 6.8 - 6.9 7.1 7.3 - 7.5 7.6 7.9 - 7.9 8.1 8.4 - 8.4 8.6 8.9 - 8.9 9.1 9.4 - HI PR 224 241 255 - 252 271 286 - 286 308 325 - 326 351 370 - 367 394 417 - 405 436 460 - LO PR 107 114 124 - 113 120 131 - 117 125 136 - 123 131 143 - 129 137 150 - 134 142 155 - MBh 24.5 25.2 27.3 29.3 23.9 24.7 26.7 28.6 23.4 24.1 26.0 28.0 22.8 23.5 S/T 0.84 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 Delta T 20 18 15 10 20 19 15 11 20 19 15 11 20 19 955 KW 1.58 1.62 1.67 1.73 1.71 1.75 1.81 1.87 1.82 1.87 1.93 2.00 1.92 1.97 A MPS 6.7 6.8 7.1 7.3 7.2 7.4 7.6 7.9 7.8 8.0 8.2 8.5 8.3 8.5 HI PR 236 254 268 279 265 285 301 314 301 324 342 357 343 369 LO PR 112 120 131 139 119 126 138 147 123 131 143 153 130 138 MBh 23.8 24.5 26.5 28.5 23.2 23.9 25.9 27.8 22.7 23.4 25.3 27.1 22.1 22.8 S/T 0.81 0.72 0.55 0.35 0.83 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.88 0.79 Delta T 21 19 16 11 21 19 16 11 21 19 16 11 21 19 75 850 KW A MPS 1.57 1.60 1.66 1.71 1.70 1.73 1.79 1.85 1.81 1.85 1.91 1.98 1.91 1.95 6.6 6.8 7.0 7.2 7.1 7.3 7.5 7.8 7.7 7.9 8.1 8.4 8.2 8.4 HI PR 233 251 265 277 262 282 298 310 298 321 339 353 339 365 LO PR 111 118 129 138 118 125 137 145 122 130 142 151 128 137 MBh 22.0 22.6 24.5 26.3 21.5 22.1 23.9 25.7 20.9 21.6 23.3 25.1 20.4 21.0 S/T 0.78 0.69 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.85 0.76 Delta T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 745 KW 1.53 1.56 1.61 1.67 1.65 1.69 1.75 1.81 1.76 1.80 1.86 1.93 1.86 1.90 A MPS HI PR 6.5 6.6 6.8 7.1 7.0 7.1 7.3 7.6 7.5 7.7 7.9 8.2 8.0 8.2 226 244 257 268 254 273 289 301 289 311 328 343 329 354 LO PR 108 115 125 134 114 121 133 141 119 126 138 147 125 133 * IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA ) conditions High and low pressures are measured at the liquid and suction access f ittings. 25.4 0.63 15 2.04 8.7 389 151 24.7 0.60 16 2.02 8.7 386 149 22.8 0.58 16 1.97 8.4 374 145 27.3 0.40 11 2.11 9.1 406 160 26.5 0.38 11 2.09 9.0 402 159 24.4 0.37 11 2.03 8.7 390 154 21.7 0.96 20 2.01 8.8 386 136 21.0 0.92 21 1.99 8.7 382 135 19.4 0.88 21 1.94 8.5 370 131 22.3 0.86 18 2.06 9.0 415 145 21.7 0.82 19 2.04 8.9 411 143 20.0 0.79 20 1.98 8.7 398 139 24.1 0.65 15 2.13 9.3 438 158 23.4 0.62 16 2.11 9.2 434 156 21.6 0.60 16 2.05 9.0 421 152 25.9 0.42 10 2.20 9.6 457 168 25.2 0.40 11 2.18 9.5 452 166 23.2 0.39 11 2.12 9.3 439 161 20.1 0.97 19 2.08 9.3 426 141 19.5 0.92 19 2.06 9.2 422 139 18.0 0.89 20 2.01 9.0 409 135 20.7 0.87 17 2.13 9.5 458 150 20.1 0.83 18 2.11 9.4 454 148 18.5 0.80 18 2.06 9.2 440 144 22.4 0.66 14 2.20 9.8 484 163 21.7 0.63 15 2.19 9.7 479 162 20.0 0.60 15 2.13 9.5 465 157 24.0 0.42 10 2.28 10.2 505 174 23.3 0.40 10 2.26 10.1 500 172 21.5 0.39 10 2.20 9.8 485 167 *PC1424H41** 21 COOLING PERFORMANCE DATA 22 MODEL: *PC1424H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 9 ± 2°F @ the liquid acce s s fitting conne ction AHRI 95 te s t conditions . De s ign Supe r he at 5 ± 2°F @ the com pre s s or s uction acce s s fitting conne ction. Outdoor Am bie nt Te m pe r atur e 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe r ature Air flo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 25.0 25.5 27.2 29.1 24.4 24.9 26.6 28.4 23.8 24.3 26.0 27.8 23.2 23.7 25.3 27.1 22.0 22.5 24.1 25.7 20.4 20.9 22.3 23.8 S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.81 0.61 Delta T 22 21 19 15 23 22 19 15 23 22 19 15 22 22 19 15 21 22 19 15 20 20 17 14 955 KW 1.60 1.63 1.69 1.74 1.72 1.76 1.82 1.89 1.84 1.88 1.95 2.01 1.94 1.99 2.05 2.13 2.03 2.07 2.15 2.22 2.10 2.15 2.22 2.30 A MPS 6.8 6.9 7.1 7.4 7.3 7.4 7.7 7.9 7.9 8.0 8.3 8.6 8.4 8.6 8.8 9.1 8.9 9.1 9.4 9.7 9.4 9.6 9.9 10.3 HI PR 238 256 271 282 267 288 304 317 304 327 345 360 346 373 393 410 389 419 443 462 430 463 489 510 LO PR 114 121 132 140 120 128 139 148 125 133 145 154 131 139 152 162 137 146 159 170 142 151 165 176 MBh 24.2 24.8 26.4 28.3 23.7 24.2 25.8 27.6 23.1 23.6 25.2 27.0 22.5 23.0 24.6 26.3 21.4 21.9 23.4 25.0 19.8 20.3 21.6 23.1 S/T 0.88 0.83 0.67 0.50 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.57 1.00 0.95 0.77 0.58 Delta T 23 22 19 15 23 22 20 16 23 22 20 16 24 23 20 16 23 22 19 16 21 21 18 14 80 850 KW 1.58 1.62 1.67 1.73 1.71 1.75 1.81 1.87 1.82 1.87 1.93 2.00 1.92 1.97 2.04 2.11 2.01 2.06 2.13 2.20 2.08 2.13 2.21 2.28 A MPS 6.7 6.8 7.1 7.3 7.2 7.4 7.6 7.9 7.8 8.0 8.2 8.5 8.3 8.5 8.8 9.1 8.8 9.0 9.3 9.6 9.3 9.5 9.8 10.2 HI PR 236 254 268 279 265 285 301 314 301 324 342 357 343 369 390 406 386 415 438 457 426 458 484 505 LO PR 112 120 131 139 119 126 138 147 123 131 143 153 130 138 151 160 136 145 158 168 141 150 163 174 MBh 22.4 22.8 24.4 26.1 21.8 22.3 23.8 25.5 21.3 21.8 23.3 24.9 20.8 21.3 22.7 24.3 19.8 20.2 21.6 23.1 18.3 18.7 20.0 21.4 S/T 0.85 0.80 0.65 0.49 0.88 0.83 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.88 0.71 0.53 0.97 0.91 0.74 0.55 0.98 0.92 0.75 0.56 Delta T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 18 15 745 KW 1.54 1.58 1.63 1.68 1.67 1.70 1.76 1.82 1.78 1.82 1.88 1.94 1.87 1.92 1.98 2.05 1.96 2.00 2.07 2.14 2.03 2.07 2.15 2.22 A MPS 6.5 6.7 6.9 7.1 7.0 7.2 7.4 7.7 7.6 7.8 8.0 8.3 8.1 8.3 8.5 8.8 8.6 8.8 9.0 9.4 9.0 9.3 9.6 9.9 HI PR 229 246 260 271 257 276 292 304 292 314 332 346 332 358 378 394 374 403 425 443 413 445 470 490 LO PR 109 116 127 135 115 123 134 143 120 127 139 148 126 134 146 156 132 140 153 163 136 145 158 169 NOTE: Shaded area ref lects AHRI rating conditions MBh 25.4 25.9 27.1 28.9 24.8 25.3 26.5 28.2 24.2 24.7 25.8 27.6 23.6 24.1 25.2 26.9 22.4 22.9 24.0 25.6 20.8 21.2 22.2 23.7 S/T 0.97 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.79 Delta T 24 23 22 19 24 24 22 19 23 24 22 19 23 23 23 19 22 22 22 19 20 20 21 18 955 KW 1.61 1.64 1.70 1.76 1.74 1.78 1.84 1.90 1.86 1.90 1.96 2.03 1.96 2.00 2.07 2.14 2.04 2.09 2.16 2.24 2.12 2.17 2.24 2.32 A MPS 6.8 7.0 7.2 7.4 7.3 7.5 7.7 8.0 7.9 8.1 8.4 8.7 8.4 8.6 8.9 9.2 8.9 9.2 9.5 9.8 9.5 9.7 10.0 10.4 HI PR 241 259 273 285 270 290 307 320 307 330 349 364 350 376 397 414 393 423 447 466 435 468 494 515 LO PR 115 122 133 142 121 129 141 150 126 134 146 156 132 141 154 164 139 148 161 172 143 153 167 177 MBh 24.6 25.1 26.3 28.1 24.1 24.5 25.7 27.4 23.5 24.0 25.1 26.8 22.9 23.4 24.5 26.1 21.8 22.2 23.3 24.8 20.2 20.6 21.5 23.0 S/T 0.93 0.89 0.81 0.65 0.96 0.93 0.84 0.68 0.98 0.95 0.86 0.70 1.00 0.98 0.88 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75 Delta T 25 24 23 20 25 25 23 20 25 25 23 20 25 25 23 20 24 24 23 20 22 22 22 19 85 850 KW 1.60 1.63 1.69 1.74 1.72 1.76 1.82 1.89 1.84 1.88 1.95 2.01 1.94 1.99 2.05 2.13 2.03 2.07 2.15 2.22 2.10 2.15 2.22 2.30 A MPS 6.8 6.9 7.1 7.4 7.3 7.4 7.7 7.9 7.9 8.0 8.3 8.6 8.4 8.6 8.8 9.1 8.9 9.1 9.4 9.7 9.4 9.6 9.9 10.3 HI PR 238 256 271 282 267 288 304 317 304 327 345 360 346 373 393 410 389 419 443 462 430 463 489 510 LO PR 114 121 132 140 120 128 139 148 125 133 145 154 131 139 152 162 137 146 159 170 142 151 165 176 *PC1424H41** MBh 22.7 23.2 24.3 25.9 22.2 22.6 23.7 25.3 21.7 22.1 23.2 24.7 21.2 21.6 22.6 24.1 20.1 20.5 21.5 22.9 18.6 19.0 19.9 21.2 S/T 0.89 0.86 0.78 0.63 0.93 0.89 0.81 0.65 0.95 0.92 0.83 0.67 0.98 0.95 0.85 0.69 1.00 0.98 0.89 0.72 1.00 0.99 0.89 0.72 Delta T 25 25 23 20 25 25 24 20 25 25 24 20 26 25 24 21 25 25 23 20 23 23 22 19 745 KW 1.56 1.59 1.64 1.70 1.68 1.72 1.78 1.84 1.79 1.83 1.90 1.96 1.89 1.93 2.00 2.07 1.97 2.02 2.09 2.16 2.05 2.09 2.17 2.24 A MPS 6.6 6.7 6.9 7.2 7.1 7.2 7.5 7.7 7.7 7.8 8.1 8.4 8.1 8.3 8.6 8.9 8.6 8.8 9.1 9.4 9.1 9.3 9.6 10.0 HI PR 231 249 263 274 259 279 295 307 295 317 335 349 336 361 382 398 378 407 429 448 417 449 474 495 LO PR 110 117 128 136 116 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 147 160 170 * NOTE: Shaded area is A HRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system pow er High and low pressures are measured at the liquid and suction access f ittings. AMPS: Unit amps (comp.+ evaporator + condenser f an motors) COOLING PERFORMANCE DATA MODEL: *PC1430H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 10 ± 2 °F @ the liquid acce s s fitting conne ction ARI 95 te s t conditions . De s ign Supe r he at 10 ± 2 °F @ the com pre s s or s uction acce s s fitting conne ction. Outdoor Am bient Tem pe rature 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe r atur e Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 1180 MBh 27.8 28.8 31.6 - 27.2 28.2 30.9 - 26.5 27.5 30.1 - 25.9 26.8 29.4 S/T 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.81 0.67 0.47 - 0.83 0.70 0.48 Delta T 16 14 11 - 17 14 11 - 17 14 11 - 17 15 11 KW 1.86 1.90 1.96 - 2.01 2.06 2.12 - 2.14 2.19 2.27 - 2.26 2.31 2.39 AMPS 7.7 7.9 8.1 - 8.3 8.5 8.7 - 8.9 9.1 9.4 - 9.5 9.7 10.0 HI PR 240 258 272 - 269 289 305 - 306 329 347 - 348 375 396 LO PR 111 119 129 - 118 125 137 - 122 130 142 - 128 137 149 - 24.6 25.5 27.9 - 22.8 23.6 25.9 - - 0.87 0.72 0.50 - 0.87 0.73 0.50 - - 17 14 11 - 15 13 10 - - 2.36 2.41 2.50 - 2.44 2.50 2.59 - - 10.1 10.3 10.7 - 10.7 10.9 11.3 - - 392 421 445 - 433 466 492 - - 135 143 156 - 139 148 162 - MBh 27.0 28.0 30.7 - 26.4 27.4 30.0 - 25.8 26.7 29.3 - 25.1 26.1 28.5 S/T 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.80 0.66 0.46 Delta T 17 15 11 - 17 15 11 - 17 15 11 - 18 15 11 70 1050 KW 1.84 1.89 1.95 - 1.99 2.04 2.11 - 2.12 2.17 2.25 - 2.24 2.29 2.37 AMPS 7.6 7.8 8.0 - 8.2 8.4 8.6 - 8.9 9.1 9.3 - 9.4 9.6 10.0 HI PR 237 255 269 - 266 286 302 - 303 326 344 - 345 371 392 LO PR 110 117 128 - 117 124 135 - 121 129 141 - 127 135 148 - 23.9 24.7 27.1 - 22.1 22.9 25.1 - - 0.83 0.69 0.48 - 0.83 0.70 0.48 - - 17 15 11 - 16 14 11 - - 2.34 2.39 2.47 - 2.42 2.48 2.56 - - 10.0 10.2 10.6 - 10.6 10.8 11.2 - - 388 417 441 - 428 461 487 - - 133 142 155 - 138 147 160 - MBh 24.9 25.8 28.3 - 24.4 25.2 27.7 - 23.8 24.6 27.0 - 23.2 24.0 26.3 - 22.0 22.8 25.0 - 20.4 21.2 23.2 - S/T 0.70 0.58 0.40 - 0.72 0.61 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 - Delta T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 - 920 KW 1.80 1.84 1.90 - 1.94 1.99 2.05 - 2.07 2.12 2.19 - 2.18 2.23 2.31 - 2.28 2.33 2.41 - 2.36 2.41 2.50 - AMPS 7.4 7.6 7.8 - 8.0 8.2 8.4 - 8.6 8.8 9.1 - 9.2 9.4 9.7 - 9.7 10.0 10.3 - 10.3 10.5 10.9 - HI PR 230 248 261 - 258 278 293 - 294 316 334 - 334 360 380 - 376 405 427 - 416 447 472 - LO PR 107 114 124 - 113 120 131 - 117 125 136 - 123 131 143 - 129 138 150 - 134 142 155 - MBh 28.3 29.1 31.5 33.9 27.6 28.5 30.8 33.1 27.0 27.8 30.1 32.3 26.3 27.1 S/T 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 Delta T 19 18 14 10 19 18 15 10 19 18 15 10 19 18 1180 KW 1.88 1.92 1.98 2.05 2.03 2.07 2.14 2.22 2.16 2.21 2.29 2.36 2.28 2.33 AMPS 7.8 7.9 8.2 8.5 8.3 8.5 8.8 9.1 9.0 9.2 9.5 9.8 9.6 9.8 HI PR 242 260 275 287 272 292 309 322 309 332 351 366 352 378 LO PR 113 120 131 139 119 126 138 147 124 131 143 153 130 138 MBh 27.5 28.3 30.6 32.9 26.8 27.6 29.9 32.1 26.2 27.0 29.2 31.3 25.6 26.3 S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.78 0.59 0.38 0.90 0.81 Delta T 20 18 15 10 20 18 15 10 20 19 15 10 20 19 75 1050 KW 1.86 1.90 1.96 2.03 2.01 2.06 2.12 2.20 2.14 2.19 2.27 2.34 2.26 2.31 AMPS 7.7 7.9 8.1 8.4 8.3 8.5 8.7 9.0 8.9 9.1 9.4 9.8 9.5 9.7 HI PR 240 258 272 284 269 289 305 319 306 329 347 362 348 375 LO PR 111 119 129 138 118 125 137 146 122 130 142 151 128 137 MBh 25.4 26.1 28.3 30.3 24.8 25.5 27.6 29.6 24.2 24.9 26.9 28.9 23.6 24.3 S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.76 0.57 0.37 0.87 0.78 Delta T 20 19 15 10 20 19 15 11 20 19 15 11 21 19 920 KW 1.81 1.85 1.92 1.98 1.96 2.00 2.07 2.14 2.09 2.14 2.21 2.28 2.20 2.25 AMPS 7.5 7.7 7.9 8.2 8.1 8.2 8.5 8.8 8.7 8.9 9.2 9.5 9.3 9.5 HI PR 232 250 264 275 261 281 296 309 297 319 337 351 338 363 LO PR 108 115 126 134 114 121 133 141 119 126 138 147 125 133 * IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA ) conditions High and low pressures are measured at the liquid and suction access f ittings. 29.3 0.64 15 2.41 10.1 400 151 28.5 0.61 15 2.39 10.0 396 149 26.3 0.59 16 2.33 9.8 384 145 31.5 0.41 10 2.49 10.5 417 161 30.6 0.39 11 2.47 10.4 413 159 28.2 0.38 11 2.41 10.1 400 154 25.0 0.98 19 2.38 10.2 396 136 24.3 0.94 20 2.36 10.1 392 135 22.4 0.90 20 2.30 9.8 380 131 25.8 0.88 18 2.43 10.4 426 145 25.0 0.84 18 2.41 10.3 422 143 23.1 0.81 19 2.35 10.1 409 139 27.9 0.67 14 2.52 10.7 450 158 27.1 0.64 15 2.50 10.7 445 156 25.0 0.61 15 2.43 10.4 432 152 29.9 0.43 10 2.61 11.1 469 168 29.0 0.41 10 2.58 11.0 464 167 26.8 0.39 11 2.52 10.7 450 162 23.2 0.99 18 2.47 10.8 437 141 22.5 0.95 19 2.44 10.7 433 139 20.8 0.91 19 2.38 10.4 420 135 23.9 0.89 16 2.52 11.0 470 150 23.2 0.85 17 2.50 10.9 466 148 21.4 0.82 17 2.44 10.6 452 144 25.8 0.67 14 2.61 11.4 497 163 25.1 0.64 14 2.59 11.3 492 162 23.1 0.62 14 2.52 11.0 477 157 27.7 0.43 9 2.70 11.8 518 174 26.9 0.41 10 2.68 11.7 513 172 24.8 0.40 10 2.61 11.4 498 167 *PC1430H41** 23 COOLING PERFORMANCE DATA 24 MODEL: *PC1430H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 10 ± 2 °F @ the liquid acce s s fitting conne ction ARI 95 te s t conditions . De s ign Supe rhe at 10 ± 2 °F @ the com pre s s or s uction acce s s fitting conne ction. Outdoor Am bie nt Te m pe r atur e 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe r ature Air flo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 1180 MBh S/T Delta T KW A MPS HI PR LO PR 28.8 0.95 21 1.89 7.8 244 114 29.4 0.89 20 1.93 8.0 263 121 31.4 0.72 18 2.00 8.2 278 132 33.6 0.54 14 2.07 8.5 290 141 28.1 1.00 22 2.04 8.4 274 120 28.7 0.92 21 2.09 8.6 295 128 30.7 0.75 18 2.16 8.9 312 139 32.8 0.56 14 2.23 9.2 325 149 27.5 1.00 21 2.18 9.1 312 125 28.1 0.94 21 2.23 9.3 336 133 30.0 0.77 18 2.30 9.6 354 145 32.1 0.57 14 2.38 9.9 370 154 26.8 1.00 21 2.30 9.7 355 131 27.4 1.00 21 2.35 9.9 382 139 29.3 0.79 18 2.43 10.2 404 152 31.3 0.59 14 2.52 10.6 421 162 25.5 1.00 20 2.40 10.3 400 137 26.0 1.00 20 2.46 10.5 430 146 27.8 0.82 18 2.54 10.8 454 160 29.7 0.62 14 2.63 11.2 474 170 23.6 1.00 18 2.49 10.9 442 142 24.1 1.00 19 2.55 11.1 475 151 25.7 0.83 17 2.63 11.5 502 165 27.5 0.62 13 2.73 11.9 523 176 MBh 28.0 28.6 30.5 32.6 27.3 27.9 29.8 31.9 26.7 27.2 29.1 31.1 26.0 26.6 28.4 30.4 24.7 25.3 27.0 28.8 22.9 23.4 25.0 26.7 S/T 0.90 0.85 0.69 0.52 0.94 0.88 0.72 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.97 0.79 0.59 Delta T 22 21 18 15 22 21 19 15 22 21 19 15 23 22 19 15 22 21 19 15 20 20 17 14 80 1050 KW 1.88 1.92 1.98 2.05 2.03 2.07 2.14 2.22 2.16 2.21 2.29 2.36 2.28 2.33 2.41 2.49 2.38 2.43 2.52 2.61 2.47 2.52 2.61 2.70 A MPS 7.8 7.9 8.2 8.5 8.3 8.5 8.8 9.1 9.0 9.2 9.5 9.8 9.6 9.8 10.1 10.5 10.2 10.4 10.7 11.1 10.8 11.0 11.4 11.8 HI PR 242 260 275 287 272 292 309 322 309 332 351 366 352 379 400 417 396 426 450 469 437 470 497 518 LO PR 113 120 131 139 119 126 138 147 124 131 144 153 130 138 151 161 136 145 158 168 141 150 163 174 MBh 25.8 26.4 28.2 30.1 25.2 25.8 27.5 29.4 24.6 25.1 26.9 28.7 24.0 24.5 26.2 28.0 22.8 23.3 24.9 26.6 21.1 21.6 23.1 24.7 S/T 0.87 0.82 0.67 0.50 0.90 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.94 0.76 0.57 Delta T 22 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 21 20 18 14 920 KW 1.83 1.87 1.93 2.00 1.98 2.02 2.09 2.16 2.11 2.15 2.23 2.30 2.22 2.27 2.35 2.43 2.32 2.37 2.45 2.54 2.40 2.46 2.54 2.63 A MPS 7.6 7.7 8.0 8.2 8.1 8.3 8.6 8.9 8.8 9.0 9.3 9.6 9.3 9.6 9.9 10.2 9.9 10.1 10.5 10.8 10.5 10.7 11.1 11.5 HI PR 235 253 267 278 263 283 299 312 300 322 340 355 341 367 388 404 384 413 436 455 424 456 482 503 LO PR 109 116 127 135 115 123 134 143 120 128 139 148 126 134 146 156 132 140 153 163 136 145 159 169 NOTE: Shaded area ref lects AHRI rating conditions 1180 MBh S/T Delta T KW A MPS HI PR LO PR 29.3 0.99 23 1.91 7.9 247 115 29.9 0.96 22 1.95 8.1 266 122 31.3 0.87 21 2.01 8.3 281 133 33.4 0.70 18 2.08 8.6 293 142 28.6 1.00 22 2.06 8.5 277 121 29.2 0.99 23 2.11 8.7 298 129 30.6 0.90 21 2.18 8.9 315 141 32.6 0.73 18 2.25 9.3 328 150 27.9 1.00 22 2.20 9.2 315 126 28.5 1.00 22 2.25 9.4 339 134 29.8 0.92 21 2.32 9.7 358 146 31.8 0.75 18 2.41 10.0 373 156 27.3 1.00 21 2.32 9.8 359 132 27.8 1.00 22 2.37 10.0 386 141 29.1 0.95 22 2.45 10.3 408 154 31.1 0.77 19 2.54 10.7 425 164 25.9 1.00 20 2.42 10.4 404 139 26.4 1.00 21 2.48 10.6 434 148 27.7 0.99 21 2.56 10.9 459 161 29.5 0.80 18 2.65 11.3 478 172 24.0 1.00 19 2.51 10.9 446 144 24.5 1.00 19 2.57 11.2 480 153 25.6 0.99 20 2.66 11.6 507 167 27.3 0.81 17 2.75 12.0 529 178 MBh 28.5 29.0 30.4 32.4 27.8 28.3 29.7 31.7 27.1 27.7 29.0 30.9 26.5 27.0 28.3 30.1 25.1 25.6 26.8 28.6 23.3 23.7 24.9 26.5 S/T 0.95 0.91 0.83 0.67 0.98 0.95 0.86 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77 Delta T 24 23 22 19 24 24 22 19 24 24 22 19 23 24 22 19 22 22 22 19 20 21 21 18 85 1050 KW 1.89 1.93 2.00 2.07 2.04 2.09 2.16 2.23 2.18 2.23 2.30 2.38 2.30 2.35 2.43 2.52 2.40 2.46 2.54 2.63 2.49 2.55 2.63 2.73 A MPS 7.8 8.0 8.2 8.5 8.4 8.6 8.9 9.2 9.1 9.3 9.6 9.9 9.7 9.9 10.2 10.6 10.3 10.5 10.8 11.2 10.9 11.1 11.5 11.9 HI PR 244 263 278 290 274 295 312 325 312 336 354 370 355 382 404 421 400 430 454 474 442 475 502 523 LO PR 114 121 132 141 120 128 139 149 125 133 145 154 131 139 152 162 137 146 160 170 142 151 165 176 *PC1430H41** MBh 26.3 26.8 28.0 29.9 25.7 26.1 27.4 29.2 25.0 25.5 26.7 28.5 24.4 24.9 26.1 27.8 23.2 23.7 24.8 26.4 21.5 21.9 23.0 24.5 S/T 0.91 0.88 0.80 0.65 0.95 0.91 0.82 0.67 0.97 0.94 0.85 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.91 0.74 Delta T 24 24 22 19 24 24 23 20 24 24 23 20 24 24 23 20 23 24 22 19 21 22 21 18 920 KW 1.84 1.89 1.95 2.01 1.99 2.04 2.11 2.18 2.12 2.17 2.25 2.32 2.24 2.29 2.37 2.45 2.34 2.39 2.47 2.56 2.42 2.48 2.56 2.65 A MPS 7.6 7.8 8.0 8.3 8.2 8.4 8.6 8.9 8.9 9.1 9.3 9.7 9.4 9.6 10.0 10.3 10.0 10.2 10.6 10.9 10.6 10.8 11.2 11.6 HI PR 237 255 269 281 266 286 302 315 303 326 344 359 345 371 392 408 388 417 441 459 428 461 487 508 LO PR 110 117 128 136 116 124 135 144 121 129 141 150 127 135 148 157 133 142 155 165 138 147 160 171 * NOTE: Shaded area is A HRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system pow er High and low pressures are measured at the liquid and suction access f ittings. AMPS: Unit amps (comp.+ evaporator + condenser f an motors) COOLING PERFORMANCE DATA MODEL: *PC1436H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 10 ±2 °F @ the liquid acce s s fitting conne ction ARI 95 te s t conditions . De s ign Supe rhe at 9 ±2 °F @ the com pr e s s or s uction acce s s fitting conne ction. Outdoor Am bie nt Te m pe ratur e 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe r atur e Air flow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 1349 MBh 34.9 36.2 39.6 - 34.1 35.3 38.7 - 33.3 34.5 37.8 - 32.5 33.6 S/T 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 Delta T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 KW 2.33 2.38 2.45 - 2.51 2.57 2.65 - 2.67 2.73 2.82 - 2.81 2.88 A MPS 10.5 10.8 11.0 - 11.3 11.5 11.8 - 12.1 12.3 12.7 - 12.8 13.1 HI PR 238 256 271 - 267 288 304 - 304 327 345 - 346 372 LO PR 107 114 125 - 114 121 132 - 118 126 137 - 124 132 36.9 0.48 12 2.97 13.4 393 144 - 30.8 32.0 35.0 - 28.6 29.6 32.4 - - 0.87 0.72 0.50 - 0.87 0.73 0.51 - - 18 16 12 - 17 15 11 - - 2.93 3.00 3.10 - 3.04 3.11 3.21 - - 13.5 13.8 14.2 - 14.2 14.5 14.9 - - 389 419 442 - 430 463 489 - - 130 138 151 - 134 143 156 - MBh 33.9 35.1 38.5 - 33.1 34.3 37.6 - 32.3 33.5 36.7 - 31.5 32.7 35.8 S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.64 0.45 - 0.80 0.67 0.46 Delta T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 70 1200 KW 2.31 2.36 2.43 - 2.49 2.54 2.63 - 2.65 2.71 2.80 - 2.79 2.85 2.95 A MPS 10.5 10.7 11.0 - 11.2 11.4 11.7 - 12.0 12.2 12.6 - 12.7 12.9 13.3 HI PR 236 254 268 - 265 285 301 - 301 324 342 - 343 369 389 LO PR 106 113 124 - 112 120 131 - 117 124 136 - 123 131 143 - 29.9 31.0 34.0 - 27.7 28.7 31.5 - - 0.83 0.69 0.48 - 0.83 0.70 0.48 - - 19 16 12 - 18 15 12 - - 2.91 2.97 3.07 - 3.01 3.08 3.18 - - 13.4 13.7 14.1 - 14.1 14.4 14.8 - - 386 415 438 - 426 458 484 - - 129 137 149 - 133 142 155 - 1052 MBh 31.3 32.4 35.5 - 30.5 31.6 34.7 - 29.8 30.9 33.8 - 29.1 30.1 S/T 0.70 0.58 0.41 - 0.73 0.61 0.42 - 0.74 0.62 0.43 - 0.77 0.64 Delta T 19 17 13 - 19 17 13 - 19 17 13 - 20 17 KW 2.25 2.30 2.37 - 2.43 2.48 2.56 - 2.58 2.64 2.73 - 2.72 2.78 A MPS 10.2 10.4 10.7 - 10.9 11.1 11.4 - 11.7 11.9 12.3 - 12.4 12.6 HI PR 229 246 260 - 257 276 292 - 292 314 332 - 332 358 LO PR 103 110 120 - 109 116 127 - 113 121 132 - 119 127 33.0 0.44 13 2.87 13.0 378 138 - 27.6 28.6 31.4 - 25.6 26.5 29.1 - - 0.80 0.67 0.46 - 0.80 0.67 0.47 - - 19 17 13 - 18 16 12 - - 2.84 2.90 3.00 - 2.94 3.00 3.10 - - 13.1 13.3 13.7 - 13.7 14.0 14.4 - - 374 402 425 - 413 445 470 - - 125 133 145 - 129 137 150 - MBh 35.5 36.5 39.5 42.4 34.7 35.7 38.6 41.4 33.8 34.8 37.7 40.5 33.0 34.0 S/T 0.87 0.77 0.59 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 Delta T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 1349 KW A MPS 2.35 2.40 2.47 2.56 2.53 2.59 2.67 2.76 2.69 2.75 2.84 2.94 2.84 2.90 10.6 10.8 11.1 11.5 11.3 11.6 11.9 12.3 12.2 12.4 12.8 13.2 12.9 13.2 HI PR 241 259 273 285 270 290 307 320 307 330 349 364 350 376 LO PR 109 116 126 134 115 122 133 142 119 127 138 147 125 133 MBh 34.4 35.5 38.4 41.2 33.6 34.6 37.5 40.2 32.8 33.8 36.6 39.3 32.0 33.0 S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.78 0.59 0.38 0.91 0.81 Delta T 22 20 16 11 22 20 17 11 22 20 17 11 22 20 75 1200 KW 2.33 2.38 2.45 2.54 2.51 2.57 2.65 2.74 2.67 2.73 2.82 2.92 2.81 2.88 A MPS 10.5 10.8 11.0 11.4 11.3 11.5 11.8 12.2 12.1 12.3 12.7 13.1 12.8 13.1 HI PR 238 256 271 282 267 288 304 317 304 327 345 360 346 373 LO PR 107 114 125 133 114 121 132 140 118 126 137 146 124 132 MBh 31.8 32.7 35.4 38.0 31.1 32.0 34.6 37.1 30.3 31.2 33.8 36.3 29.6 30.4 S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.87 0.78 Delta T 22 20 17 12 22 21 17 12 22 21 17 12 23 21 1052 KW 2.27 2.32 2.39 2.47 2.45 2.50 2.58 2.67 2.60 2.66 2.75 2.84 2.74 2.80 A MPS 10.3 10.5 10.8 11.1 11.0 11.2 11.5 11.9 11.8 12.0 12.4 12.8 12.5 12.7 HI PR 231 249 263 274 259 279 295 307 295 317 335 349 336 361 LO PR 104 111 121 129 110 117 128 136 114 122 133 142 120 128 * IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TV A) conditions High and low pressures are measured at the liquid and suction access f ittings. 36.8 0.64 16 3.00 13.5 397 145 35.7 0.61 17 2.97 13.4 393 144 33.0 0.59 17 2.90 13.1 382 140 39.5 0.41 11 3.10 14.0 414 155 38.3 0.39 12 3.07 13.9 410 153 35.4 0.38 12 2.99 13.5 398 149 31.4 0.99 21 2.96 13.6 393 131 30.4 0.94 22 2.93 13.5 389 130 28.1 0.91 22 2.86 13.2 378 126 32.3 0.88 19 3.03 13.9 423 140 31.3 0.84 20 3.00 13.8 419 138 28.9 0.81 21 2.92 13.4 407 134 34.9 0.67 16 3.13 14.3 447 152 33.9 0.64 17 3.10 14.2 443 151 31.3 0.61 17 3.02 13.8 429 146 37.5 0.43 11 3.24 14.8 466 162 36.4 0.41 11 3.21 14.7 462 161 33.6 0.39 12 3.12 14.3 448 156 29.0 0.99 20 3.06 14.3 435 136 28.2 0.95 20 3.04 14.2 430 134 26.0 0.91 21 2.96 13.8 417 130 29.9 0.89 18 3.13 14.6 468 144 29.0 0.85 19 3.11 14.5 463 143 26.8 0.82 19 3.03 14.1 449 139 32.4 0.67 15 3.24 15.1 494 158 31.4 0.64 15 3.21 14.9 489 156 29.0 0.62 16 3.13 14.6 474 151 34.7 0.43 10 3.35 15.6 515 168 33.7 0.41 11 3.32 15.4 510 166 31.1 0.40 11 3.24 15.0 495 161 *PC1436H41** 25 COOLING PERFORMANCE DATA 26 MODEL: *PC1436H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 10 ±2 °F @ the liquid acce s s fitting conne ction ARI 95 te s t conditions . De s ign Supe r he at 9 ±2 °F @ the com pr e s s or s uction acce s s fitting conne ction. Outdoor Am bient Te m pe rature 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe r atur e Air flow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 1349 MBh S/T Delta T KW A MPS HI PR LO PR 36.1 36.9 39.4 42.1 35.3 36.0 38.5 41.2 34.4 35.2 37.6 40.2 33.6 0.95 0.89 0.72 0.54 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 23 22 19 16 24 23 20 16 23 23 20 16 23 2.37 2.42 2.50 2.58 2.55 2.61 2.69 2.78 2.72 2.78 2.87 2.97 2.86 10.7 10.9 11.2 11.6 11.4 11.7 12.0 12.4 12.3 12.5 12.9 13.3 13.0 243 261 276 288 273 293 310 323 310 334 352 368 353 110 117 127 136 116 123 135 143 120 128 140 149 126 34.3 1.00 23 2.93 13.3 380 135 36.7 0.80 20 3.02 13.6 401 147 39.2 31.9 32.6 34.8 37.2 29.6 30.2 32.3 34.5 0.59 1.00 1.00 0.83 0.62 1.00 1.00 0.83 0.62 16 22 22 20 16 20 21 18 15 3.13 2.98 3.05 3.15 3.26 3.09 3.16 3.27 3.38 14.1 13.7 14.0 14.4 14.9 14.4 14.7 15.2 15.7 419 397 428 451 471 439 472 499 520 156 133 141 154 164 137 146 159 170 MBh 35.1 35.8 38.3 40.9 34.2 35.0 37.4 40.0 33.4 34.2 36.5 39.0 32.6 33.3 35.6 38.1 31.0 31.7 33.8 36.2 28.7 29.3 31.3 33.5 S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.97 0.79 0.59 Delta T 24 23 20 16 25 24 21 16 25 24 21 16 25 24 21 17 24 23 20 16 22 22 19 15 80 1200 KW 2.35 2.40 2.48 2.56 2.53 2.59 2.67 2.76 2.69 2.75 2.84 2.94 2.84 2.90 3.00 3.10 2.96 3.03 3.13 3.24 3.06 3.13 3.24 3.35 A MPS 10.6 10.8 11.1 11.5 11.3 11.6 11.9 12.3 12.2 12.4 12.8 13.2 12.9 13.2 13.5 14.0 13.6 13.9 14.3 14.8 14.3 14.6 15.1 15.6 HI PR 241 259 273 285 270 290 307 320 307 330 349 364 350 376 397 414 393 423 447 466 435 468 494 515 LO PR 109 116 126 134 115 122 133 142 119 127 138 147 125 133 145 155 131 140 152 162 136 144 158 168 1052 MBh S/T Delta T KW A MPS HI PR LO PR 32.4 33.1 35.3 37.8 31.6 32.3 34.5 36.9 30.9 31.5 33.7 36.0 30.1 0.87 0.82 0.67 0.50 0.90 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 25 24 21 16 25 24 21 17 25 24 21 17 25 2.29 2.34 2.41 2.49 2.47 2.52 2.60 2.69 2.63 2.68 2.77 2.87 2.77 10.4 10.6 10.9 11.2 11.1 11.3 11.6 12.0 11.9 12.1 12.5 12.9 12.6 233 251 265 277 262 282 298 310 298 320 338 353 339 105 112 122 130 111 118 129 138 116 123 134 143 121 30.8 0.90 24 2.83 12.8 365 129 32.9 0.73 21 2.92 13.2 385 141 35.1 28.6 29.2 31.2 33.4 26.5 27.1 28.9 30.9 0.55 0.99 0.93 0.76 0.57 1.00 0.94 0.77 0.57 17 25 24 21 17 23 22 19 15 3.02 2.88 2.95 3.05 3.15 2.99 3.05 3.16 3.26 13.6 13.3 13.6 14.0 14.4 14.0 14.3 14.7 15.2 402 382 411 434 452 422 454 479 500 150 127 135 148 157 132 140 153 163 NOTE: Shaded area ref lects AHRI rating conditions 1349 MBh S/T Delta T KW A MPS HI PR LO PR 36.7 37.4 39.2 41.8 35.9 36.6 38.3 40.9 35.0 35.7 37.4 39.9 34.2 1.00 0.96 0.87 0.70 1.00 1.00 0.90 0.73 1.00 1.00 0.92 0.75 1.00 25 25 23 20 24 25 23 20 24 24 23 20 23 2.39 2.44 2.52 2.60 2.57 2.63 2.72 2.81 2.74 2.80 2.89 2.99 2.89 10.8 11.0 11.3 11.7 11.5 11.8 12.1 12.5 12.4 12.6 13.0 13.4 13.1 245 264 279 291 275 296 313 326 313 337 356 371 357 111 118 129 137 117 124 136 145 122 129 141 150 128 34.8 1.00 24 2.95 13.4 384 136 36.5 0.95 24 3.05 13.8 405 148 38.9 32.5 33.1 34.7 37.0 30.1 30.7 32.1 34.3 0.77 1.00 1.00 0.99 0.80 1.00 1.00 1.00 0.81 20 22 23 23 20 21 21 22 19 3.15 3.01 3.08 3.18 3.29 3.12 3.19 3.30 3.41 14.2 13.8 14.1 14.5 15.0 14.5 14.9 15.3 15.8 423 401 432 456 476 443 477 504 525 158 134 142 155 166 138 147 161 171 MBh 35.7 36.4 38.1 40.6 34.8 35.5 37.2 39.7 34.0 34.7 36.3 38.7 33.2 33.8 35.4 37.8 31.5 32.1 33.7 35.9 29.2 29.8 31.2 33.3 S/T 0.95 0.92 0.83 0.67 0.98 0.95 0.86 0.70 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77 Delta T 26 26 24 21 26 26 24 21 26 26 24 21 25 26 25 21 24 25 24 21 22 23 23 20 85 1200 KW 2.37 2.42 2.50 2.58 2.55 2.61 2.69 2.78 2.72 2.78 2.87 2.97 2.86 2.93 3.02 3.13 2.98 3.05 3.15 3.26 3.09 3.16 3.27 3.38 A MPS 10.7 10.9 11.2 11.6 11.4 11.7 12.0 12.4 12.3 12.5 12.9 13.3 13.0 13.3 13.6 14.1 13.7 14.0 14.4 14.9 14.4 14.7 15.2 15.7 HI PR 243 261 276 288 273 293 310 323 310 334 352 368 353 380 401 419 397 428 451 471 439 472 499 520 LO PR 110 117 127 136 116 123 135 143 120 128 140 149 126 135 147 156 133 141 154 164 137 146 159 170 *PC1436H41** 1052 MBh S/T Delta T KW A MPS HI PR LO PR 32.9 33.6 35.1 37.5 32.2 32.8 34.3 36.6 31.4 32.0 33.5 35.8 30.6 0.92 0.88 0.80 0.65 0.95 0.92 0.83 0.67 0.97 0.94 0.85 0.69 1.00 26 26 24 21 27 26 25 21 27 26 25 21 27 2.31 2.36 2.43 2.51 2.49 2.54 2.63 2.71 2.65 2.71 2.80 2.89 2.79 10.5 10.7 11.0 11.3 11.2 11.4 11.7 12.1 12.0 12.2 12.6 13.0 12.7 236 254 268 279 264 285 301 313 301 324 342 356 343 106 113 124 132 112 120 131 139 117 124 136 144 123 31.2 0.97 26 2.85 12.9 369 131 32.7 0.87 25 2.95 13.3 389 142 34.9 29.1 29.7 31.1 33.1 26.9 27.5 28.8 30.7 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.74 22 25 26 25 21 24 24 23 20 3.05 2.91 2.97 3.07 3.18 3.01 3.08 3.18 3.29 13.8 13.4 13.7 14.1 14.5 14.1 14.4 14.8 15.3 406 385 415 438 457 426 458 484 505 152 129 137 149 159 133 141 154 165 * NOTE: Shaded areas is A HRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system pow er High and low pressures are measured at the liquid and suction access f ittings. A MPS: Unit amps (comp.+ evaporator + condenser f an motors) COOLING PERFORMANCE DATA MODEL: *PC1442H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 8 ± 2 °F @ the liquid acce s s fitting conne ction AHRI 95 te s t conditions . De s ign Supe rhe at 8 ± 2 °F @ the com pr e s s or s uction acce s s fitting conne ction. Outdoor Am bient Tem pe rature 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe r atur e Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 1461 MBh 39.7 41.1 45.1 - 38.8 40.2 44.0 - 37.8 39.2 43.0 - 36.9 38.3 S/T 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.82 0.69 Delta T 19 16 12 - 19 16 12 - 19 16 12 - 19 17 KW 2.54 2.60 2.68 - 2.74 2.80 2.89 - 2.92 2.98 3.08 - 3.07 3.14 AMPS 11.6 11.8 12.1 - 12.4 12.6 13.0 - 13.3 13.6 14.0 - 14.1 14.4 HI PR 236 254 268 - 265 285 301 - 301 324 342 - 343 369 LO PR 110 116 127 - 116 123 134 - 120 128 140 - 126 134 41.9 0.48 13 3.25 14.9 390 147 - 35.1 36.4 39.8 - 32.5 33.7 36.9 - - 0.86 0.71 0.49 - 0.86 0.72 0.50 - - 19 16 12 - 18 15 12 - - 3.21 3.28 3.39 - 3.32 3.40 3.51 - - 14.9 15.3 15.7 - 15.7 16.1 16.6 - - 386 415 439 - 426 459 485 - - 132 141 154 - 137 146 159 - MBh 38.5 39.9 43.8 - 37.6 39.0 42.7 - 36.7 38.1 41.7 - 35.8 37.1 40.7 S/T 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.45 Delta T 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 70 1300 KW 2.52 2.58 2.66 - 2.72 2.78 2.87 - 2.89 2.96 3.06 - 3.05 3.12 3.22 AMPS 11.5 11.7 12.0 - 12.3 12.5 12.9 - 13.2 13.5 13.9 - 14.0 14.3 14.7 HI PR 234 251 266 - 262 282 298 - 298 321 339 - 340 366 386 LO PR 108 115 126 - 115 122 133 - 119 127 138 - 125 133 145 - 34.1 35.3 38.7 - 31.5 32.7 35.8 - - 0.82 0.68 0.47 - 0.82 0.69 0.48 - - 20 17 13 - 18 16 12 - - 3.18 3.25 3.36 - 3.29 3.37 3.48 - - 14.8 15.1 15.6 - 15.6 15.9 16.4 - - 382 411 434 - 422 454 480 - - 131 139 152 - 136 144 157 - 1139 MBh 35.6 36.9 40.4 - 34.7 36.0 39.4 - 33.9 35.1 38.5 - 33.1 34.3 S/T 0.69 0.58 0.40 - 0.72 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 Delta T 20 17 13 - 20 17 13 - 20 17 13 - 20 18 KW 2.46 2.51 2.59 - 2.65 2.71 2.80 - 2.82 2.88 2.98 - 2.97 3.04 AMPS 11.2 11.4 11.8 - 12.0 12.2 12.6 - 12.9 13.2 13.5 - 13.7 14.0 HI PR 227 244 258 - 254 274 289 - 289 311 329 - 329 355 LO PR 105 112 122 - 111 118 129 - 115 123 134 - 121 129 37.6 0.44 13 3.14 14.4 374 141 - 31.4 32.6 35.7 - 29.1 30.2 33.1 - - 0.79 0.66 0.46 - 0.79 0.66 0.46 - - 20 17 13 - 19 16 12 - - 3.10 3.17 3.27 - 3.21 3.28 3.39 - - 14.4 14.8 15.2 - 15.2 15.5 16.0 - - 371 399 421 - 410 441 465 - - 127 135 148 - 131 140 153 - MBh 40.4 41.6 45.0 48.3 39.4 40.6 43.9 47.2 38.5 39.6 42.9 46.0 37.5 38.7 S/T 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.39 0.91 0.81 0.61 0.40 0.94 0.84 Delta T 22 20 16 11 22 20 17 11 22 20 17 11 22 20 1461 KW 2.56 2.62 2.70 2.79 2.77 2.83 2.92 3.02 2.94 3.01 3.11 3.21 3.10 3.17 AMPS 11.7 11.9 12.2 12.6 12.5 12.7 13.1 13.5 13.4 13.7 14.1 14.6 14.2 14.5 HI PR 238 257 271 283 268 288 304 317 304 327 346 361 347 373 LO PR 111 118 128 137 117 124 136 145 121 129 141 150 128 136 MBh 39.2 40.3 43.7 46.9 38.3 39.4 42.7 45.8 37.4 38.5 41.6 44.7 36.5 37.5 S/T 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.87 0.77 0.59 0.38 0.89 0.80 Delta T 23 21 17 12 23 21 17 12 23 21 17 12 23 21 75 1300 KW 2.54 2.60 2.68 2.77 2.74 2.80 2.89 2.99 2.92 2.98 3.08 3.19 3.07 3.14 AMPS 11.6 11.8 12.1 12.5 12.4 12.6 13.0 13.4 13.3 13.6 14.0 14.5 14.1 14.4 HI PR 236 254 268 280 265 285 301 314 301 324 342 357 343 369 LO PR 110 117 127 135 116 123 134 143 120 128 140 149 126 134 MBh 36.2 37.2 40.3 43.3 35.3 36.4 39.4 42.3 34.5 35.5 38.4 41.2 33.6 34.6 S/T 0.79 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.75 0.56 0.36 0.86 0.77 Delta T 23 21 17 12 23 21 18 12 23 21 18 12 23 22 1139 KW A MPS 2.48 2.53 2.62 2.70 2.67 2.73 2.82 2.92 2.85 2.91 3.00 3.11 3.00 3.06 11.3 11.5 11.9 12.2 12.1 12.3 12.7 13.1 13.0 13.3 13.7 14.1 13.8 14.1 HI PR 229 246 260 271 257 277 292 305 292 314 332 346 333 358 LO PR 106 113 123 131 112 119 130 139 117 124 135 144 123 130 * IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA ) conditions High and low pressures are measured at the liquid and suction access f ittings. 41.8 0.63 17 3.28 15.0 394 148 40.6 0.60 17 3.25 14.9 390 147 37.5 0.58 18 3.17 14.5 378 142 44.9 0.41 12 3.39 15.5 411 158 43.6 0.39 12 3.36 15.4 407 156 40.2 0.38 12 3.27 15.0 394 152 35.7 0.97 22 3.23 15.1 390 134 34.6 0.93 23 3.21 14.9 386 132 32.0 0.89 23 3.13 14.6 374 128 36.7 0.87 20 3.31 15.4 420 142 35.7 0.83 21 3.28 15.3 415 141 32.9 0.80 21 3.20 14.9 403 137 39.7 0.66 16 3.42 15.8 443 155 38.6 0.63 17 3.39 15.7 439 154 35.6 0.61 17 3.30 15.3 425 149 42.7 0.42 11 3.54 16.4 462 165 41.4 0.40 12 3.51 16.3 458 164 38.2 0.39 12 3.42 15.8 444 159 33.0 0.98 20 3.35 15.9 431 138 32.1 0.93 21 3.32 15.7 427 137 29.6 0.90 22 3.24 15.3 414 133 34.0 0.88 19 3.43 16.2 464 147 33.0 0.84 20 3.40 16.1 459 146 30.5 0.81 20 3.31 15.7 445 141 36.8 0.66 15 3.54 16.7 490 161 35.7 0.63 16 3.51 16.6 485 159 33.0 0.61 16 3.42 16.1 470 154 39.5 0.43 11 3.66 17.3 511 171 38.4 0.41 11 3.63 17.1 506 169 35.4 0.39 11 3.54 16.7 490 164 *PC1442H41** 27 COOLING PERFORMANCE DATA 28 MODEL: *PC1442H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 8 ± 2 °F @ the liquid acce s s fitting conne ction AHRI 95 te s t conditions . De s ign Supe rhe at 8 ± 2 °F @ the com pre s s or s uction acce s s fitting conne ction. Outdoor Am bient Te m pe rature 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe r atur e Air flow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 1461 MBh S/T Delta T KW A MPS HI PR LO PR 41.1 42.0 44.8 47.9 40.1 41.0 43.8 46.8 39.2 40.0 42.8 45.7 38.2 0.94 0.88 0.71 0.53 0.97 0.91 0.74 0.55 1.00 0.93 0.76 0.57 1.00 24 23 20 16 25 23 20 16 25 24 20 16 24 2.58 2.64 2.73 2.82 2.79 2.85 2.94 3.04 2.97 3.03 3.14 3.24 3.13 11.8 12.0 12.3 12.7 12.6 12.8 13.2 13.6 13.5 13.8 14.2 14.7 14.4 241 259 274 285 270 291 307 320 307 331 349 364 350 112 119 130 138 118 126 137 146 123 131 142 152 129 39.0 0.96 24 3.20 14.7 377 137 41.7 0.78 21 3.30 15.1 398 150 44.6 36.3 37.1 39.6 42.4 33.6 34.4 36.7 39.2 0.59 1.00 1.00 0.81 0.61 1.00 1.00 0.82 0.61 16 23 23 20 16 21 22 19 15 3.42 3.26 3.34 3.45 3.57 3.38 3.46 3.57 3.70 15.6 15.2 15.5 16.0 16.5 16.0 16.3 16.8 17.4 415 394 424 448 467 435 468 494 516 159 135 144 157 167 140 149 162 173 MBh 39.9 40.8 43.5 46.5 39.0 39.8 42.5 45.5 38.0 38.9 41.5 44.4 37.1 37.9 40.5 43.3 35.2 36.0 38.5 41.1 32.6 33.4 35.6 38.1 S/T 0.89 0.84 0.68 0.51 0.93 0.87 0.71 0.53 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 1.00 0.95 0.78 0.58 1.00 0.96 0.78 0.59 Delta T 25 24 21 17 25 24 21 17 26 24 21 17 26 25 21 17 25 24 21 17 23 23 20 16 80 1300 KW 2.56 2.62 2.70 2.79 2.77 2.83 2.92 3.02 2.94 3.01 3.11 3.21 3.10 3.17 3.28 3.39 3.23 3.31 3.42 3.54 3.35 3.43 3.54 3.67 A MPS 11.7 11.9 12.2 12.6 12.5 12.7 13.1 13.5 13.4 13.7 14.1 14.6 14.2 14.5 15.0 15.5 15.1 15.4 15.8 16.4 15.9 16.2 16.7 17.3 HI PR 238 257 271 283 268 288 304 317 304 327 346 361 347 373 394 411 390 420 443 462 431 464 490 511 LO PR 111 118 128 137 117 124 136 145 121 129 141 150 128 136 148 158 134 142 155 165 138 147 161 171 1139 MBh S/T Delta T KW A MPS HI PR LO PR 36.8 37.6 40.2 43.0 36.0 36.7 39.3 42.0 35.1 35.9 38.3 41.0 34.2 0.86 0.81 0.66 0.49 0.89 0.84 0.68 0.51 0.92 0.86 0.70 0.52 0.94 26 25 21 17 26 25 22 17 26 25 22 17 26 2.50 2.56 2.64 2.72 2.70 2.76 2.85 2.94 2.87 2.93 3.03 3.13 3.02 11.4 11.6 12.0 12.3 12.2 12.4 12.8 13.2 13.1 13.4 13.8 14.2 13.9 231 249 263 274 260 279 295 308 295 318 335 350 336 107 114 125 133 113 121 132 140 118 125 137 146 124 35.0 0.89 25 3.09 14.2 362 132 37.4 0.72 22 3.19 14.6 382 144 40.0 32.5 33.2 35.5 38.0 30.1 30.8 32.9 35.2 0.54 0.98 0.92 0.75 0.56 0.99 0.93 0.75 0.56 17 26 25 21 17 24 23 20 16 3.30 3.15 3.22 3.33 3.45 3.26 3.34 3.45 3.57 15.1 14.7 15.0 15.4 16.0 15.5 15.8 16.3 16.8 398 378 407 430 448 418 450 475 495 153 130 138 151 160 134 143 156 166 NOTE: Shaded area ref lects AHRI rating conditions 1461 MBh S/T Delta T KW A MPS HI PR LO PR 41.8 42.6 44.6 47.6 40.8 41.6 43.6 46.5 39.9 40.6 42.5 45.4 38.9 0.98 0.95 0.85 0.69 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 26 25 24 21 26 26 24 21 25 26 24 21 24 2.61 2.66 2.75 2.84 2.81 2.87 2.97 3.07 2.99 3.06 3.16 3.27 3.15 11.8 12.1 12.4 12.8 12.7 12.9 13.3 13.8 13.6 13.9 14.3 14.8 14.5 243 262 276 288 273 294 310 324 310 334 353 368 354 113 120 131 140 119 127 138 147 124 132 144 153 130 39.6 1.00 25 3.22 14.8 380 138 41.5 0.94 24 3.33 15.2 402 151 44.3 36.9 37.6 39.4 42.1 34.2 34.9 36.5 39.0 0.76 1.00 1.00 0.97 0.79 1.00 1.00 0.98 0.80 21 23 24 24 21 22 22 23 20 3.45 3.29 3.36 3.48 3.60 3.41 3.49 3.60 3.73 15.7 15.3 15.6 16.1 16.7 16.1 16.5 17.0 17.6 419 398 428 452 471 439 473 499 521 161 136 145 158 169 141 150 164 175 MBh 40.6 41.4 43.3 46.2 39.6 40.4 42.3 45.1 38.7 39.4 41.3 44.1 37.7 38.5 40.3 43.0 35.9 36.6 38.3 40.8 33.2 33.9 35.5 37.8 S/T 0.94 0.90 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.70 1.00 0.99 0.89 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.94 0.76 Delta T 27 26 25 22 27 27 25 22 27 27 25 22 27 27 25 22 25 26 25 22 23 24 23 20 85 1300 KW 2.58 2.64 2.73 2.82 2.79 2.85 2.94 3.04 2.97 3.03 3.14 3.24 3.13 3.20 3.30 3.42 3.26 3.34 3.45 3.57 3.38 3.46 3.57 3.70 A MPS 11.8 12.0 12.3 12.7 12.6 12.8 13.2 13.6 13.5 13.8 14.2 14.7 14.4 14.7 15.1 15.6 15.2 15.5 16.0 16.5 16.0 16.3 16.8 17.4 HI PR 241 259 274 285 270 291 307 320 307 331 349 364 350 377 398 415 394 424 448 467 435 468 494 516 LO PR 112 119 130 138 118 126 137 146 123 131 142 152 129 137 150 159 135 144 157 167 140 149 162 173 *PC1442H41** 1139 MBh S/T Delta T KW A MPS HI PR LO PR 37.5 38.2 40.0 42.7 36.6 37.3 39.1 41.7 35.7 36.4 38.1 40.7 34.8 0.90 0.87 0.79 0.64 0.94 0.90 0.81 0.66 0.96 0.93 0.84 0.68 0.99 27 27 25 22 28 27 26 22 28 27 26 22 28 2.52 2.58 2.66 2.75 2.72 2.78 2.87 2.97 2.89 2.96 3.06 3.16 3.05 11.5 11.7 12.0 12.4 12.3 12.5 12.9 13.3 13.2 13.5 13.9 14.3 14.0 234 251 265 277 262 282 298 311 298 321 339 353 340 108 115 126 134 115 122 133 142 119 127 138 147 125 35.5 0.96 27 3.12 14.3 365 133 37.2 0.86 26 3.22 14.7 386 145 39.7 33.1 33.7 35.3 37.7 30.7 31.3 32.7 34.9 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.90 0.73 22 27 27 26 22 25 25 24 21 3.33 3.18 3.25 3.36 3.48 3.29 3.37 3.48 3.60 15.2 14.8 15.1 15.6 16.1 15.6 15.9 16.4 17.0 402 382 411 434 453 422 454 480 500 155 131 139 152 162 136 144 157 168 * NOTE: Shaded areas is A HRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system pow er High and low pressures are measured at the liquid and suction access f ittings. A MPS: Unit amps (comp.+ evaporator + condenser f an motors) COOLING PERFORMANCE DATA MODEL: *PC1448H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 10 ± 2 °F @ the liquid acce s s fitting conne ction AHRI 95 te s t conditions . De s ign Supe rhe at 10 ± 2°F @ the com pre s s or s uction acce s s fitting conne ction. Outdoor Am bient Tem perature 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe r atur e Air flow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 1800 MBh 45.6 47.2 51.7 - 44.5 46.1 50.5 S/T 0.76 0.64 0.44 - 0.79 0.66 0.46 Delta T 18 15 12 - 18 16 12 KW 2.94 3.01 3.10 - 3.17 3.24 3.34 AMPS 12.7 13.0 13.4 - 13.7 14.0 14.4 HI PR 236 254 268 - 264 284 300 LO PR 110 117 128 - 117 124 135 - 43.4 45.0 49.3 - 42.4 43.9 - 0.81 0.68 0.47 - 0.84 0.70 - 18 16 12 - 18 16 - 3.37 3.44 3.56 - 3.55 3.63 - 14.7 15.0 15.5 - 15.6 16.0 - 301 324 342 - 342 369 - 121 129 141 - 127 135 48.1 0.48 12 3.75 16.5 389 148 - 40.3 41.7 45.7 - 37.3 38.7 42.4 - - 0.87 0.73 0.50 - 0.88 0.73 0.51 - - 18 15 12 - 17 14 11 - - 3.70 3.78 3.91 - 3.83 3.91 4.04 - - 16.6 16.9 17.4 - 17.5 17.9 18.4 - - 385 415 438 - 426 458 484 - - 133 142 155 - 138 147 160 - MBh 44.2 45.9 50.2 - 43.2 44.8 49.1 - 42.2 43.7 47.9 - 41.2 42.7 46.7 S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.65 0.45 - 0.80 0.67 0.46 Delta T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 70 1600 KW 2.92 2.98 3.08 - 3.14 3.21 3.32 - 3.34 3.42 3.53 - 3.52 3.60 3.71 AMPS 12.6 12.9 13.3 - 13.6 13.8 14.3 - 14.6 14.9 15.4 - 15.5 15.9 16.3 HI PR 233 251 265 - 262 282 297 - 298 320 338 - 339 365 385 LO PR 109 116 127 - 116 123 134 - 120 128 139 - 126 134 146 - 39.1 40.5 44.4 - 36.2 37.5 41.1 - - 0.83 0.69 0.48 - 0.84 0.70 0.48 - - 19 16 12 - 17 15 11 - - 3.67 3.75 3.87 - 3.80 3.88 4.01 - - 16.4 16.8 17.3 - 17.3 17.7 18.2 - - 381 410 433 - 421 454 479 - - 132 141 153 - 137 145 159 - 1400 MBh 40.8 42.3 46.4 - 39.9 41.3 45.3 S/T 0.70 0.59 0.41 - 0.73 0.61 0.42 Delta T 19 16 12 - 19 16 13 KW 2.85 2.91 3.00 - 3.07 3.13 3.23 AMPS 12.3 12.6 13.0 - 13.2 13.5 13.9 HI PR 226 243 257 - 254 273 289 LO PR 106 113 123 - 112 119 130 - 38.9 40.4 44.2 - 38.0 39.4 - 0.75 0.62 0.43 - 0.77 0.64 - 19 16 13 - 19 17 - 3.26 3.33 3.44 - 3.43 3.51 - 14.2 14.5 15.0 - 15.1 15.5 - 289 311 328 - 329 354 - 116 124 135 - 122 130 43.1 0.45 13 3.62 15.9 374 142 - 36.1 37.4 41.0 - 33.4 34.6 38.0 - - 0.80 0.67 0.46 - 0.81 0.67 0.47 - - 19 16 12 - 18 15 12 - - 3.57 3.65 3.78 - 3.70 3.78 3.91 - - 16.0 16.4 16.9 - 16.9 17.2 17.8 - - 370 398 420 - 409 440 465 - - 128 136 149 - 133 141 154 - MBh S/T 46.3 47.7 51.6 55.4 45.3 46.6 50.4 54.1 44.2 45.5 49.2 52.8 43.1 44.4 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 Delta T 21 19 15 11 21 19 16 11 21 19 16 11 21 19 1800 KW 2.97 3.03 3.13 3.23 3.20 3.27 3.37 3.48 3.40 3.47 3.59 3.71 3.58 3.66 AMPS 12.8 13.1 13.5 14.0 13.8 14.1 14.5 15.0 14.8 15.2 15.6 16.2 15.8 16.1 HI PR 238 256 270 282 267 287 303 317 304 327 345 360 346 372 LO PR 112 119 130 138 118 125 137 146 122 130 142 152 129 137 MBh 45.0 46.3 50.1 53.8 43.9 45.2 49.0 52.6 42.9 44.2 47.8 51.3 41.9 43.1 S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.59 0.38 0.91 0.81 Delta T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 75 1600 KW 2.94 3.01 3.10 3.20 3.17 3.24 3.34 3.45 3.37 3.44 3.56 3.68 3.55 3.63 AMPS 12.7 13.0 13.4 13.8 13.7 14.0 14.4 14.9 14.7 15.0 15.5 16.0 15.6 16.0 HI PR 236 254 268 279 264 285 300 313 301 324 342 356 343 369 LO PR 110 118 128 137 117 124 136 144 121 129 141 150 127 136 MBh 41.5 42.8 46.3 49.7 40.6 41.8 45.2 48.5 39.6 40.8 44.1 47.4 38.6 39.8 S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.87 0.78 Delta T 22 20 16 11 22 20 17 11 22 20 17 11 22 20 1400 KW 2.87 2.93 3.03 3.12 3.09 3.16 3.26 3.37 3.29 3.36 3.47 3.58 3.46 3.54 A MPS HI PR LO PR 12.4 229 107 12.7 246 114 13.1 260 124 13.5 271 133 13.3 256 113 13.6 276 120 14.0 291 131 14.5 304 140 14.4 292 118 14.7 314 125 15.1 331 137 15.6 346 146 15.2 332 124 15.6 358 131 * IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TV A) conditions High and low pressures are measured at the liquid and suction access f ittings. 48.0 0.64 16 3.78 16.6 393 149 46.6 0.61 16 3.75 16.5 389 148 43.0 0.59 17 3.65 16.1 378 144 51.6 0.41 11 3.90 17.2 410 159 50.1 0.40 11 3.87 17.0 406 158 46.2 0.38 12 3.77 16.6 394 153 41.0 0.99 21 3.73 16.7 389 135 39.8 0.94 22 3.70 16.6 385 134 36.7 0.91 22 3.61 16.1 374 129 42.2 0.88 19 3.81 17.1 419 143 40.9 0.84 20 3.78 16.9 415 142 37.8 0.81 20 3.69 16.5 402 138 45.6 0.67 16 3.94 17.6 442 157 44.3 0.64 16 3.91 17.4 438 155 40.9 0.61 17 3.81 17.0 425 150 49.0 0.43 11 4.07 18.2 461 167 47.6 0.41 11 4.04 18.1 457 165 43.9 0.40 11 3.94 17.6 443 160 37.9 1.00 19 3.86 17.6 430 139 36.8 0.95 20 3.83 17.5 426 138 34.0 0.92 20 3.73 17.0 413 134 39.1 0.89 18 3.95 18.0 463 148 37.9 0.85 18 3.91 17.9 458 147 35.0 0.82 19 3.81 17.4 444 143 42.3 0.67 15 4.08 18.6 489 162 41.0 0.64 15 4.05 18.4 484 160 37.9 0.62 15 3.94 17.9 469 156 45.4 0.43 10 4.22 19.2 510 173 44.0 0.41 10 4.18 19.1 505 171 40.7 0.40 11 4.08 18.6 489 166 *PC1448H41** 29 COOLING PERFORMANCE DATA 30 MODEL: *PC1448H41** EXPANDED PERFORMANCE DATA COOLIN G OPERATION IDB* De s ign Subcooling, 10 ± 2 °F @ the liquid acce s s fitting conne ction AHRI 95 te s t conditions . De s ign Supe r he at 10 ± 2°F @ the com pr e s s or s uction acce s s fitting conne ction. Outdoor Am bient Te m per ature 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe ratur e Air flo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 1800 MBh S/T Delta T KW A MPS HI PR LO PR 47.2 0.95 23 2.99 13.0 240 113 48.2 0.89 22 3.05 13.2 259 120 51.5 0.73 19 3.15 13.6 273 131 55.0 0.54 15 3.25 14.1 285 139 46.1 1.00 24 3.22 13.9 270 119 47.1 0.92 22 3.29 14.2 290 127 50.3 0.75 19 3.40 14.6 307 138 53.8 0.56 15 3.51 15.1 320 147 45.0 1.00 23 3.43 15.0 307 124 46.0 0.95 22 3.50 15.3 330 132 49.1 0.77 19 3.62 15.8 349 144 52.5 0.58 15 3.74 16.3 364 153 43.9 1.00 22 3.61 15.9 349 130 44.8 1.00 23 3.69 16.3 376 138 47.9 0.80 19 3.81 16.8 397 151 51.2 0.60 16 3.94 17.3 414 161 41.7 1.00 21 3.76 16.8 393 136 42.6 1.00 22 3.85 17.2 423 145 45.5 0.83 19 3.97 17.7 447 158 48.6 0.62 15 4.11 18.4 466 168 38.6 1.00 20 3.89 17.8 434 141 39.5 1.00 20 3.98 18.2 467 150 42.1 0.83 18 4.11 18.7 494 164 45.1 0.62 14 4.26 19.4 515 174 MBh 45.8 46.8 50.0 53.4 44.7 45.7 48.8 52.2 43.7 44.6 47.7 51.0 42.6 43.5 46.5 49.7 40.5 41.3 44.2 47.2 37.5 38.3 40.9 43.7 S/T 0.91 0.85 0.69 0.52 0.94 0.88 0.72 0.54 0.96 0.90 0.74 0.55 0.99 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.98 0.79 0.59 Delta T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 22 21 19 15 80 1600 KW 2.97 3.03 3.13 3.23 3.20 3.27 3.37 3.48 3.40 3.47 3.59 3.71 3.58 3.66 3.78 3.91 3.73 3.81 3.94 4.07 3.86 3.95 4.08 4.22 AMPS 12.9 13.1 13.5 14.0 13.8 14.1 14.5 15.0 14.8 15.2 15.6 16.2 15.8 16.1 16.6 17.2 16.7 17.1 17.6 18.2 17.6 18.0 18.6 19.2 HI PR 238 256 270 282 267 287 304 317 304 327 345 360 346 372 393 410 389 419 442 461 430 463 489 510 LO PR 112 119 130 138 118 125 137 146 122 130 142 152 129 137 149 159 135 143 157 167 139 148 162 173 1400 MBh S/T Delta T KW A MPS HI PR LO PR 42.3 0.87 24 2.90 12.5 231 108 43.2 0.82 23 2.96 12.8 248 115 46.1 0.67 20 3.05 13.2 262 126 49.3 0.50 16 3.15 13.6 274 134 41.3 0.91 25 3.12 13.4 259 114 42.2 0.85 24 3.19 13.7 279 122 45.1 0.69 20 3.29 14.1 294 133 48.2 0.52 16 3.40 14.6 307 141 40.3 0.93 25 3.31 14.5 295 119 41.2 0.87 24 3.39 14.8 317 126 44.0 0.71 20 3.50 15.2 335 138 47.0 0.53 16 3.61 15.8 349 147 39.3 0.96 25 3.49 15.4 336 125 40.2 0.90 24 3.57 15.7 361 133 42.9 0.73 21 3.68 16.2 381 145 45.9 0.55 16 3.81 16.8 398 154 37.3 1.00 24 3.64 16.3 378 131 38.2 0.93 23 3.72 16.6 406 139 40.8 0.76 20 3.84 17.1 429 152 43.6 0.57 16 3.97 17.7 447 162 34.6 1.00 23 3.76 17.2 417 135 35.4 0.94 22 3.85 17.5 449 144 37.8 0.77 19 3.98 18.1 474 157 40.4 0.57 15 4.11 18.7 494 167 NOTE: Shaded area ref lects AHRI rating conditions 1800 MBh S/T Delta T KW A MPS HI PR LO PR 48.0 1.00 24 3.01 13.1 243 114 48.9 0.96 24 3.08 13.3 261 121 51.2 0.87 23 3.18 13.7 276 132 54.7 0.70 20 3.28 14.2 288 141 46.9 1.00 24 3.25 14.0 272 120 47.8 1.00 24 3.32 14.3 293 128 50.0 0.90 23 3.43 14.7 310 140 53.4 0.73 20 3.54 15.2 323 149 45.8 1.00 23 3.46 15.1 310 125 46.6 1.00 24 3.53 15.4 333 133 48.8 0.92 23 3.65 15.9 352 145 52.1 0.75 20 3.77 16.4 367 155 44.6 1.00 23 3.64 16.0 353 131 45.5 1.00 23 3.72 16.4 380 140 47.7 0.95 23 3.84 16.9 401 152 50.8 0.77 20 3.97 17.5 418 162 42.4 1.00 22 3.79 17.0 397 138 43.2 1.00 22 3.88 17.4 427 146 45.3 0.99 23 4.01 17.9 451 160 48.3 0.80 20 4.14 18.5 471 170 39.3 1.00 20 3.93 17.9 439 142 40.0 1.00 20 4.02 18.3 472 151 41.9 1.00 21 4.15 18.9 499 165 44.7 0.81 18 4.29 19.6 520 176 MBh 46.6 47.5 49.7 53.1 45.5 46.4 48.6 51.8 44.4 45.3 47.4 50.6 43.3 44.2 46.3 49.4 41.2 42.0 44.0 46.9 38.1 38.9 40.7 43.4 S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77 Delta T 25 25 24 20 26 25 24 21 26 25 24 21 25 25 24 21 24 24 24 21 22 22 22 19 85 1600 KW 2.99 3.05 3.15 3.25 3.22 3.29 3.40 3.51 3.43 3.50 3.62 3.74 3.61 3.69 3.81 3.94 3.76 3.85 3.97 4.11 3.89 3.98 4.11 4.26 AMPS 13.0 13.2 13.6 14.1 13.9 14.2 14.6 15.1 15.0 15.3 15.8 16.3 15.9 16.3 16.8 17.3 16.8 17.2 17.7 18.4 17.8 18.2 18.7 19.4 HI PR 240 259 273 285 270 290 307 320 307 330 349 364 349 376 397 414 393 423 447 466 434 467 494 515 LO PR 113 120 131 139 119 127 138 147 124 132 144 153 130 138 151 161 136 145 158 168 141 150 164 174 *PC1448H41** 1400 MBh S/T Delta T KW A MPS HI PR LO PR 43.0 0.92 26 2.92 12.6 233 109 43.8 0.88 25 2.98 12.9 251 116 45.9 0.80 24 3.07 13.3 265 127 49.0 0.65 21 3.17 13.7 276 135 42.0 0.95 26 3.14 13.5 262 115 42.8 0.92 26 3.21 13.8 282 123 44.8 0.83 24 3.31 14.2 297 134 47.8 0.67 21 3.42 14.7 310 143 41.0 0.97 26 3.34 14.6 298 120 41.8 0.94 26 3.42 14.9 320 128 43.8 0.85 24 3.53 15.4 338 139 46.7 0.69 21 3.64 15.9 353 148 40.0 1.00 26 3.52 15.5 339 126 40.8 0.97 26 3.60 15.8 365 134 42.7 0.88 25 3.71 16.3 385 146 45.6 0.71 21 3.84 16.9 402 156 38.0 1.00 25 3.67 16.4 381 132 38.7 1.00 25 3.75 16.8 410 141 40.6 0.91 24 3.87 17.3 433 153 43.3 0.74 21 4.00 17.9 452 163 35.2 1.00 23 3.79 17.3 421 137 35.9 1.00 24 3.88 17.7 453 145 37.6 0.92 23 4.01 18.2 479 159 40.1 0.74 20 4.15 18.9 499 169 * NOTE: Shaded areas is A HRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system pow er High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors) COOLING PERFORMANCE DATA MODEL: *PC1460H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 6 ± 2 °F @ the liquid acce s s fitting conne ction AHRI 95 te s t conditions . De s ign Supe rhe at 9 ± 2°F @ the com pr e s s or s uction acce s s fitting conne ction. Outdoor Am bie nt Te m pe r atur e 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe r ature Air flo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 56.3 58.4 64.0 - 55.0 57.0 62.5 - 53.7 55.7 61.0 - 52.4 54.3 59.5 S/T 0.71 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 Delta T 21 18 14 - 21 18 14 - 21 18 14 - 21 18 14 1800 KW 3.70 3.78 3.91 - 4.00 4.09 4.23 - 4.26 4.36 4.51 - 4.49 4.60 4.75 A MPS 15.7 16.0 16.5 - 16.9 17.2 17.8 - 18.2 18.6 19.2 - 19.4 19.9 20.5 HI PR 238 256 271 - 267 288 304 - 304 327 345 - 346 373 393 LO PR 108 115 125 - 114 121 132 - 118 126 137 - 124 132 144 - 49.8 51.6 56.5 - 46.1 47.8 52.4 - - 0.81 0.68 0.47 - 0.82 0.69 0.47 - - 21 18 14 - 19 17 13 - - 4.69 4.80 4.96 - 4.86 4.97 5.14 - - 20.6 21.1 21.7 - 21.7 22.3 23.0 - - 390 419 443 - 430 463 489 - - 130 139 151 - 135 143 156 - MBh 54.7 56.7 62.1 - 53.4 55.4 60.7 - 52.2 54.1 59.2 - 50.9 52.7 57.8 S/T 0.68 0.57 0.39 - 0.71 0.59 0.41 - 0.72 0.60 0.42 - 0.75 0.62 0.43 Delta T 21 19 14 - 22 19 14 - 22 19 14 - 22 19 14 70 1600 KW 3.67 3.75 3.88 - 3.97 4.06 4.19 - 4.23 4.32 4.47 - 4.46 4.56 4.71 A MPS 15.6 15.9 16.4 - 16.7 17.1 17.6 - 18.1 18.5 19.1 - 19.2 19.7 20.3 HI PR 236 254 268 - 265 285 301 - 301 324 342 - 343 369 390 LO PR 107 114 124 - 113 120 131 - 117 125 136 - 123 131 143 - 48.3 50.1 54.9 - 44.8 46.4 50.9 - - 0.78 0.65 0.45 - 0.78 0.65 0.45 - - 22 19 14 - 20 17 13 - - 4.65 4.76 4.92 - 4.82 4.93 5.10 - - 20.4 20.9 21.5 - 21.6 22.1 22.8 - - 386 415 438 - 426 459 484 - - 129 137 150 - 133 142 155 - MBh 50.5 52.3 57.3 - 49.3 51.1 56.0 - 48.1 49.9 54.7 - 47.0 48.7 53.3 S/T 0.66 0.55 0.38 - 0.68 0.57 0.39 - 0.70 0.58 0.40 - 0.72 0.60 0.42 Delta T 22 19 14 - 22 19 14 - 22 19 15 - 22 19 15 1400 KW 3.58 3.66 3.78 - 3.87 3.95 4.08 - 4.12 4.21 4.35 - 4.34 4.44 4.59 A MPS 15.2 15.5 16.0 - 16.3 16.7 17.2 - 17.6 18.0 18.6 - 18.7 19.2 19.8 HI PR 229 246 260 - 257 276 292 - 292 314 332 - 333 358 378 LO PR 103 110 120 - 109 116 127 - 114 121 132 - 119 127 139 - 44.6 46.2 50.7 - 41.3 42.8 46.9 - - 0.75 0.62 0.43 - 0.75 0.63 0.44 - - 22 19 14 - 20 18 13 - - 4.53 4.63 4.79 - 4.69 4.80 4.97 - - 19.9 20.3 21.0 - 21.0 21.5 22.2 - - 374 403 425 - 413 445 470 - - 125 133 145 - 129 138 150 - MBh S/T 57.3 59.0 63.9 68.5 56.0 57.6 62.4 66.9 54.6 56.3 60.9 65.3 53.3 54.9 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.58 0.38 0.89 0.80 Delta T 24 22 18 12 24 22 18 13 24 22 18 13 24 22 1800 KW 3.73 3.82 3.94 4.07 4.03 4.12 4.26 4.41 4.30 4.40 4.55 4.70 4.53 4.64 A MPS 15.8 16.2 16.7 17.2 17.0 17.4 17.9 18.6 18.4 18.8 19.4 20.1 19.6 20.0 HI PR 241 259 273 285 270 291 307 320 307 330 349 364 350 376 LO PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 MBh 55.6 57.3 62.0 66.5 54.3 55.9 60.6 65.0 53.0 54.6 59.1 63.4 51.8 53.3 S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.74 0.56 0.36 0.85 0.76 Delta T 25 23 19 13 25 23 19 13 25 23 19 13 25 23 75 1600 KW 3.70 3.79 3.91 4.04 4.00 4.09 4.23 4.37 4.26 4.36 4.51 4.66 4.49 4.60 A MPS 15.7 16.0 16.5 17.1 16.9 17.3 17.8 18.4 18.2 18.6 19.2 19.9 19.4 19.9 HI PR 238 256 271 282 267 288 304 317 304 327 346 360 346 373 LO PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 MBh 51.3 52.9 57.2 61.4 50.2 51.6 55.9 60.0 49.0 50.4 54.6 58.6 47.8 49.2 S/T 0.75 0.67 0.51 0.33 0.77 0.69 0.52 0.34 0.79 0.71 0.54 0.35 0.82 0.73 Delta T 25 23 19 13 25 23 19 13 26 24 19 13 26 24 1400 KW 3.61 3.69 3.81 3.94 3.90 3.99 4.12 4.26 4.15 4.25 4.39 4.54 4.38 4.48 A MPS HI PR LO PR 15.3 231 105 15.6 249 111 16.1 263 121 16.7 274 129 16.4 259 110 16.8 279 118 17.3 295 128 17.9 307 137 17.8 295 115 18.2 317 122 18.7 335 133 19.4 350 142 18.9 336 121 19.3 361 128 * IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TV A) conditions High and low pressures are measured at the liquid and suction access fittings. 59.4 63.8 50.6 52.1 56.4 60.6 46.9 48.3 52.3 56.1 0.60 0.39 0.92 0.83 0.63 0.40 0.93 0.83 0.63 0.41 18 13 24 22 18 12 22 21 17 12 4.79 4.96 4.73 4.84 5.01 5.18 4.90 5.02 5.19 5.37 20.7 21.4 20.8 21.3 21.9 22.7 21.9 22.5 23.2 24.0 397 415 393 423 447 466 435 468 494 515 146 155 132 140 153 163 136 145 158 168 57.7 61.9 49.2 50.6 54.8 58.8 45.5 46.9 50.8 54.5 0.58 0.37 0.88 0.79 0.60 0.38 0.89 0.80 0.60 0.39 19 13 25 23 19 13 23 21 18 12 4.75 4.92 4.69 4.80 4.96 5.14 4.86 4.97 5.14 5.32 20.5 21.2 20.6 21.1 21.7 22.5 21.7 22.3 23.0 23.8 394 410 390 419 443 462 430 463 489 510 144 154 130 139 151 161 135 143 157 167 53.2 57.1 45.4 46.7 50.6 54.3 42.0 43.3 46.8 50.3 0.55 0.36 0.85 0.76 0.58 0.37 0.86 0.77 0.58 0.37 19 13 25 23 19 13 24 22 18 12 4.63 4.79 4.57 4.67 4.83 5.00 4.73 4.84 5.01 5.18 19.9 20.7 20.0 20.5 21.2 21.9 21.2 21.7 22.4 23.2 382 398 378 407 429 448 418 449 474 495 140 149 126 134 147 156 131 139 152 162 *PC1460H41** 31 COOLING PERFORMANCE DATA 32 MODEL: *PC1460H41** EXPANDED PERFORMANCE DATA COOLING OPERATION IDB* De s ign Subcooling, 6 ± 2 °F @ the liquid acce s s fitting conne ction AHRI 95 te s t conditions . De s ign Supe r he at 9 ± 2°F @ the com pr e s s or s uction acce s s fitting conne ction. Outdoor Am bient Tem per atur e 65 75 85 95 105 115 Ente r ing Indoor We t Bulb Te m pe rature Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 1800 MBh S/T Delta T KW A MPS HI PR LO PR 58.3 0.89 27 3.77 16.0 243 110 59.6 0.84 25 3.85 16.3 262 117 63.7 0.68 22 3.98 16.8 276 128 68.1 0.51 18 4.11 17.4 288 136 57.0 0.92 27 4.07 17.2 273 116 58.2 0.87 26 4.16 17.5 294 124 62.2 0.70 22 4.30 18.1 310 135 66.5 0.53 18 4.45 18.7 323 144 55.6 0.95 27 4.34 18.5 310 121 56.8 0.89 26 4.43 19.0 334 128 60.7 0.72 22 4.58 19.6 352 140 64.9 0.54 18 4.74 20.3 368 149 54.3 1.00 28 4.57 19.8 353 127 55.4 0.92 26 4.68 20.2 380 135 59.2 0.75 23 4.84 20.8 401 147 63.3 0.56 18 5.00 21.6 419 157 51.5 1.00 26 4.77 21.0 397 133 52.7 0.95 26 4.88 21.4 428 141 56.3 0.77 22 5.05 22.1 452 154 60.1 0.58 18 5.23 22.9 471 164 47.7 1.00 24 4.95 22.1 439 137 48.8 0.96 24 5.06 22.7 473 146 52.1 0.78 21 5.24 23.4 499 160 55.7 0.58 17 5.42 24.2 520 170 MBh 56.6 57.9 61.8 66.1 55.3 56.5 60.4 64.5 54.0 55.2 58.9 63.0 52.7 53.8 57.5 61.5 50.0 51.1 54.6 58.4 46.3 47.4 50.6 54.1 S/T 0.85 0.80 0.65 0.48 0.88 0.83 0.67 0.50 0.90 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.97 0.91 0.74 0.55 0.98 0.91 0.74 0.56 Delta T 28 26 23 18 28 27 23 19 28 27 23 19 28 27 24 19 28 27 23 19 26 25 22 17 80 1600 KW 3.73 3.82 3.94 4.08 4.03 4.13 4.26 4.41 4.30 4.40 4.55 4.70 4.53 4.64 4.80 4.96 4.73 4.84 5.01 5.18 4.90 5.02 5.19 5.37 AMPS 15.8 16.2 16.7 17.2 17.0 17.4 17.9 18.6 18.4 18.8 19.4 20.1 19.6 20.0 20.7 21.4 20.8 21.3 21.9 22.7 21.9 22.5 23.2 24.0 HI PR 241 259 273 285 270 291 307 320 307 331 349 364 350 376 398 415 394 423 447 466 435 468 494 515 LO PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168 1400 MBh S/T Delta T KW A MPS HI PR LO PR 52.3 0.82 28 3.64 15.4 233 106 53.4 0.77 27 3.72 15.8 251 112 57.1 0.63 23 3.84 16.2 265 123 61.0 0.47 19 3.97 16.8 277 131 51.0 0.85 28 3.93 16.6 262 112 52.2 0.80 27 4.02 17.0 282 119 55.7 0.65 24 4.15 17.5 298 130 59.6 0.48 19 4.29 18.1 310 138 49.8 0.87 28 4.19 17.9 298 116 50.9 0.82 27 4.28 18.3 321 123 54.4 0.66 24 4.43 18.9 339 135 58.2 0.50 19 4.58 19.6 353 143 48.6 0.90 29 4.42 19.1 339 122 49.7 0.84 27 4.52 19.5 365 130 53.1 0.69 24 4.67 20.1 386 141 56.7 0.51 19 4.83 20.8 402 151 46.2 0.93 28 4.61 20.2 382 128 47.2 0.87 27 4.71 20.7 411 136 50.4 0.71 24 4.88 21.3 434 148 53.9 0.53 19 5.05 22.1 452 158 42.8 0.94 26 4.78 21.4 422 132 43.7 0.88 25 4.89 21.9 454 140 46.7 0.72 22 5.05 22.6 479 153 49.9 0.54 18 5.23 23.4 500 163 NOTE: Shaded area reflects AHRI rating conditions 1800 MBh S/T Delta T KW A MPS HI PR LO PR 59.3 0.93 28 3.80 16.1 245 111 60.5 0.90 28 3.88 16.5 264 118 63.3 0.81 26 4.01 17.0 279 129 67.6 0.66 23 4.14 17.5 291 137 58.0 0.97 29 4.10 17.3 275 117 59.1 0.93 28 4.20 17.7 296 125 61.9 0.84 27 4.34 18.2 313 136 66.0 0.68 23 4.48 18.9 326 145 56.6 0.99 29 4.37 18.7 313 122 57.7 0.96 28 4.47 19.1 337 130 60.4 0.86 27 4.62 19.7 356 142 64.4 0.70 23 4.78 20.4 371 151 55.2 1.00 28 4.61 19.9 357 128 56.3 0.99 28 4.72 20.4 384 136 58.9 0.89 27 4.88 21.0 405 149 62.9 0.72 23 5.05 21.8 423 158 52.4 1.00 27 4.81 21.1 401 134 53.5 1.00 27 4.93 21.6 432 143 56.0 0.93 26 5.09 22.3 456 156 59.7 0.75 23 5.27 23.1 476 166 48.6 1.00 25 4.99 22.3 444 139 49.5 1.00 25 5.10 22.9 477 148 51.9 0.93 25 5.28 23.6 504 161 55.3 0.76 21 5.47 24.5 526 172 MBh 57.6 58.7 61.5 65.6 56.3 57.4 60.1 64.1 54.9 56.0 58.6 62.6 53.6 54.6 57.2 61.0 50.9 51.9 54.4 58.0 47.2 48.1 50.3 53.7 S/T 0.89 0.86 0.78 0.63 0.92 0.89 0.80 0.65 0.95 0.91 0.82 0.67 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.72 1.00 0.99 0.89 0.72 Delta T 29 29 27 24 30 29 28 24 30 29 28 24 30 30 28 24 29 29 28 24 27 27 26 22 85 1600 KW 3.77 3.85 3.98 4.11 4.07 4.16 4.30 4.45 4.34 4.43 4.58 4.74 4.57 4.68 4.84 5.00 4.77 4.88 5.05 5.23 4.95 5.06 5.24 5.42 AMPS 16.0 16.3 16.8 17.4 17.2 17.5 18.1 18.7 18.5 19.0 19.6 20.3 19.8 20.2 20.8 21.6 21.0 21.4 22.1 22.9 22.1 22.7 23.4 24.2 HI PR 243 262 276 288 273 294 310 323 310 334 352 368 353 380 401 419 397 428 452 471 439 473 499 520 LO PR 110 117 128 136 116 124 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 146 160 170 *PC1460H41** 1400 MBh S/T Delta T KW A MPS HI PR LO PR 53.2 0.86 30 3.67 15.6 236 107 54.2 0.83 30 3.75 15.9 254 113 56.8 0.75 28 3.88 16.4 268 124 60.6 0.61 24 4.01 17.0 279 132 51.9 0.89 30 3.97 16.7 265 113 52.9 0.86 30 4.05 17.1 285 120 55.4 0.78 28 4.19 17.6 301 131 59.2 0.63 24 4.33 18.2 314 139 50.7 0.91 30 4.23 18.1 301 117 51.7 0.88 30 4.32 18.5 324 125 54.1 0.79 28 4.47 19.1 342 136 57.7 0.64 24 4.62 19.7 357 145 49.5 0.94 31 4.45 19.2 343 123 50.4 0.91 30 4.56 19.7 369 131 52.8 0.82 28 4.71 20.3 389 143 56.3 0.67 25 4.87 21.0 406 152 47.0 0.98 30 4.65 20.4 386 129 47.9 0.94 30 4.76 20.9 415 137 50.2 0.85 28 4.92 21.5 438 150 53.5 0.69 24 5.09 22.3 457 159 43.5 0.99 28 4.82 21.5 426 133 44.4 0.95 28 4.93 22.1 458 142 46.5 0.86 26 5.10 22.8 484 155 49.6 0.70 23 5.28 23.6 505 165 * NOTE: Shaded areas is AHRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system pow er High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser f an motors) COOLING PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change. 2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will occur in low and high side pressures and power. A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown. A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown. A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown. A properly operating unit should be within plus or minus 3 Amps of the typical value shown. 33 WIRING DIAGRAMS *PC14[24-48]H41** WARNING HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 34 PU BK BK C BL NOTE #3 PU BL RD BK GR PU BL GR YL RD BR WH WH BL PLF YL HC RCCF BR PU RD SA (IF USED) SEE NOTE 4 BR BK YL WH GR C GN SEE NOTE 2 EM PU BR BK CM BL RD T2 RD BK T1 BK PU BK C SEE NOTE 5 / YL GND / RD RD YL LVJB GR YL RD GR WH BR BL Y R H E G R W1 M O W2 S C A ++ RD BK YL SCR COMP CONTROL BOX L1 L2 SUPPLY VOLTAGE 208-240/1/60 C T1 R C COMP T2 C C S H RCC F F S.A. NOTE #4 CM IF USED NOTE #2 N EM 1 G L 3 2 2 08 -2 40 NOTE #4 2 3 1 TR 24V EM C SEE NOTE #2 4 5 6 C R W2 W1 Y G C COMPONENT LEGEND C CM CO MP EM GND LVJB PLF RC CF SA TR CONTACTOR CONDENSER MOTOR COMPRE SSOR EVAPORATOR MOTOR EQUIPMENT GROUND LOW VOLTAGE JUNCTION B OX FEMALE PLUG / CONNECTOR RUN CAPACITOR FOR^J COMPRE SSOR AND FAN START ASSIST TRANSFORMER FACTORY WIRING LINE V OLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GRE EN OR ORA NGE PU PURPLE RD RED WH WHITE YL YELLOW NOTES: 1. REPLACEMENT WIRE MUST B E SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE E VAP ORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINA L 3 TO TERMINAL 2 ON TRANSFORMER. 4. START ASSIST FACTORY E QUIPPED WHEN REQUIRE D 5. USE COPPER CONDUCTORS ONLY. ++ USE N.E.C. CLA SS 2 WIRE SEE UNIT RATING PLATE FOR TYPE A ND SIZE OF OVER CURRENT PROTECTION Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WIRING DIAGRAMS *PC1460H41** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. PU NOTE #3 BK BK 1 23 PU C 208 240 BL 24V BL RD BK GR PU BL GR YL YL RD SA (IF USED) SEE NOTE 4 RD BR HCF RCCF WH WH BL PLF 3 69 2 58 1 47 PU BR BR BK YL WH GR C L GN 1 2 345 WH SEE NOTE 2 EM PU BR BK CM PU BL BK 2 RD T2 L2 0 RD C BK T1 L1 SEE NOTE 5 8 2 BK 4 0 / YL 1 GND / RD 60 RD YL LVJB GR YL RD GR WH BR BL T Y R H E GR W1 M O W2 C S T A ++ T RD BK YL S CR COMP CONTROL BOX HPS L1 L2 SUPPLY VOLTAGE 208-240/1/60 C T1 R T2 C C COMP C S H RCCF F S.A. NOTE #4 CM IF USED NOTE #2 N EM 1 G L 3 2 208-240 NOTE #4 3 2 1 TR 24V 4 5 6 PLF 1 EM C 2 3 SEE NOTE #2 C HPS R W2 W1 Y G C THERMOSTAT COMPONENT LEGEND C CM COMP EM GND LVJB PLF RCCF SA TR CONTACTOR CONDENSER MOTOR COMPRESSOR EVAPORATOR MOTOR EQUIPMENT GROUND LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR RUN CAPACITOR FOR COMPRESSOR AND FAN START ASSIST TRANSFORMER HPS HIGH PRESSURE SWITCH FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTINAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PU PURPLE RD RED WH WHITE YL YELLOW NOTES: 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. START ASSIST FACTORY EQUIPPED WHEN REQUIRED 5. USE COPPER CONDUCTORS ONLY. ++ USE N.E.C. CLASS 2 WIRE SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION 208-240/1/60 0140G00871 REV. B Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 35 WARNINGAcrobat Distiller 11.0 (Windows)