Handling the Remote Controller

Location of the Remote Controller

Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.

[Diagram Description: A remote control is shown pointing towards an air conditioner unit, with an 8-meter range indicated.]

Cautions

Replacing Batteries

The remote controller is powered by two dry batteries (R03/LR03x2) housed in the rear part and protected by a cover.

  1. Remove the cover by pressing and sliding off.
  2. Remove the old batteries and insert the new batteries, placing the (+) and (-) ends correctly.
  3. Reattach the cover by sliding it back into position.

NOTE: When the batteries are removed, the remote controller erases all programming. After inserting new batteries, the remote controller must be reprogrammed.

Cautions

Remote Controller Specifications

ModelRG36F1/BGEFU1
Rated Voltage3.0V (Dry batteries R03/LR03×2)
Signal Receiving Range8m
Environment23°F~140°F

Performance Features

  1. Operating Mode: AUTO, COOL, DRY, HEAT (Cooling only model without), and FAN.
  2. Timer Setting Function in 24 hours.
  3. Indoor Setting Temperature Range: 62°F~86°F.
  4. Full function of LCD (Liquid Crystal Display).

NOTE:

Function Buttons

[Diagram Description: A vertical remote control with a digital LCD display at the top. Below the display are numbered buttons 1 through 14.]

Indicators on LCD

[Diagram Description: An illustration of the remote control's LCD screen showing various indicators like 'auto', 'cool', 'dry', 'heat', 'fan', 'SET TEMP.', 'TIMER ON/OFF', 'silence', 'sleep', 'follow me', 'lock', 'run', and temperature/fan speed displays.]

Note: All indicators shown in the figure are for clear presentation. During actual operation, only the relevant functional signs are shown on the display window.

How to Use the Buttons

Auto Operation

Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing.

  1. Press the MODE Button (2) to select Auto.
  2. Press the TEMP UP Button (8) or TEMP DOWN Button (9) to set the desired temperature. The temperature can be set within a range of 62°F~86°F in 1°F increments.
  3. Press the ON/OFF Button (1) to start the air conditioner.

NOTE:

Cooling/Heating/Fan Operation

Ensure the unit is plugged in and power is available.

  1. Press the MODE Button (2) to select COOL, HEAT (cooling & heating models only), or FAN mode.
  2. Press the TEMP UP Button (8) or TEMP DOWN Button (9) to set the desired temperature. The temperature can be set within a range of 62°F~86°F in 1°F increments.
  3. Press the FAN SPEED Button (11) to select the fan speed in four steps: AUTO, LOW, MED, or HIGH.
  4. Press the ON/OFF Button (1) to start the air conditioner.

NOTE: In the FAN mode, the setting temperature is not displayed on the remote controller, and you cannot control the room temperature. In this case, only steps 1, 3, and 4 may be performed.

Dehumidifying Operation

Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing.

  1. Press the MODE Button (2) to select DRY mode.
  2. Press the TEMP UP Button (8) or TEMP DOWN Button (9) to set the desired temperature. The temperature can be set within a range of 62°F~86°F in 1°F increments.
  3. Press the ON/OFF Button (1) to start the air conditioner.

NOTE: In the Dehumidifying mode, you cannot switch the fan speed; it is automatically controlled.

Adjusting Air Flow Direction

Use the SWING Button (Horizontal) (3) and SWING Button (Vertical) (4) to adjust the desired airflow direction.

  1. When pushing the SWING Button (Horizontal) (3), the horizontal louver changes 6 degrees in angle for each push. If pushing for more than 2 seconds, the louver will automatically swing up and down.
  2. When pushing the SWING Button (Vertical) (4), the vertical louver changes 6 degrees in angle for each push. If pushing for more than 2 seconds, the louver will automatically swing left and right.

NOTE: When the horizontal/vertical louver swings or moves to a position that would affect the cooling or heating effect of the air conditioner, it would automatically change the swing/moving direction.

Timer Operation

Press the TIMER ON Button (12) to set the auto-on time of the unit. Press the TIMER OFF Button (13) to set the auto-off time of the unit.

To Set the Auto-on Time

  1. Press the TIMER ON Button (12). The remote controller shows TIMER ON, the last Auto-on setting time, and the signal 'h' on the LCD display area. It is now ready to reset the Auto-on time to START the operation.
  2. Push the TIMER ON Button (12) again to set the desired Auto-on time. Each time you press the button, the time increases by half an hour between 0 and 10 hours, and by one hour between 10 and 24 hours.
  3. After setting the TIMER ON, there will be a one-second delay before the remote controller transmits the signal to the air conditioner. Then, after approximately another 2 seconds, the signal 'h' will disappear, and the set temperature will reappear on the LCD display window.

To Set the Auto-off Time

  1. Press the TIMER OFF Button (13). The remote controller shows TIMER OFF, the last Auto-off setting time, and the signal 'h' on the LCD display area. It is now ready to reset the Auto-off time to STOP the operation.
  2. Push the TIMER OFF Button (13) again to set the desired Auto-off time. Each time you press the button, the time increases by half an hour between 0 and 10 hours, and by one hour between 10 and 24 hours.
  3. After setting the TIMER OFF, there will be a one-second delay before the remote controller transmits the signal to the air conditioner. Then, after approximately another 2 seconds, the signal 'h' will disappear, and the set temperature will reappear on the LCD display window.

CAUTION

Example of Timer Setting

[Diagram Description: An illustration of the remote's timer display showing '6.0h' with 'TIMER ON' indicator active, and a timeline indicating 'Set', 'Start', '6 hours later'.]

TIMER ON (Auto-on Operation)

The TIMER ON feature is useful when you want the unit to turn on automatically before you return home. The air conditioner will automatically start operating at the set time.

Example: To start the air conditioner in 6 hours.

  1. Press the TIMER ON Button (12), the last setting of starting operation time and the signal 'h' will show on the display area.
  2. Press the TIMER ON Button (12) to display "6:0h" on the TIMER ON display of the remote controller.
  3. Wait for 3 seconds, and the digital display area will show the temperature again. The "TIMER ON" indicator remains on, and this function is activated.

TIMER OFF (Auto-off Operation)

The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed. The air conditioner will stop automatically at the set time.

[Diagram Description: An illustration of the remote's timer display showing '10h' with 'TIMER OFF' indicator active, and a timeline indicating 'Set', 'Stop', '10 hours later'.]

Example: To stop the air conditioner in 10 hours.

  1. Press the TIMER OFF Button (13), the last setting of stopping operation time and the signal 'h' will show on the display area.
  2. Press the TIMER OFF Button (13) to display "10h" on the TIMER OFF display of the remote controller.
  3. Wait for 3 seconds, and the digital display area will show the temperature again. The "TIMER OFF" indicator remains on, and this function is activated.

COMBINED TIMER

(Setting both ON and OFF timers simultaneously)

TIMER OFF → TIMER ON (On → Stop → Start operation)

This feature is useful when you want to stop the air conditioner after you go to bed, and start it again in the morning when you wake up or when you return home.

Example: To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.

  1. Press the TIMER OFF Button (13).
  2. Press the TIMER OFF Button (13) again to display 2.0h on the TIMER OFF display.
  3. Press the TIMER ON Button (12).
  4. Press the TIMER ON Button (12) again to display 10h on the TIMER ON display.
  5. Wait for 3 seconds, and the digital display area will show the temperature again. The "TIMER ON OFF" indicator remains on, and this function is activated.

TIMER ON → TIMER OFF

(Off → Start → Stop operation)

This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house.

[Diagram Description: An illustration of the remote's timer display showing '5.0h' with 'TIMER ON OFF' indicator active, and a timeline indicating 'Set', '2 hours later', 'Start', 'Stop', '5 hours later'.]

Example: To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.

  1. Press the TIMER ON Button (12).
  2. Press the TIMER ON Button (12) again to display 2.0h on the TIMER ON display.
  3. Press the TIMER OFF Button (13).
  4. Press the TIMER OFF Button (13) again to display 5.0h on the TIMER OFF display.
  5. Wait for 3 seconds, and the digital display area will show the temperature again. The "TIMER ON OFF" indicator remains on, and this function is activated.

Additional Functions

LED/FOLLOW ME Function

Press this button less than 2 seconds to initiate the LED function. If kept pressed for more than 2 seconds, the FOLLOW ME function is initiated.

TURBO/SELF CLEAN Function

PDF preview unavailable. Download the PDF instead.

Quick-Start-Guide Adobe PDF library 10.01 Adobe Illustrator(R) 16.0

Related Documents

PreviewOLMO SIERRA Series Remote Controller Instructions and Operation Guide
A comprehensive guide to operating the OLMO SIERRA Series air conditioner remote controller, detailing all modes, functions, setup procedures, and limited warranty information.
PreviewOLMO Split Air Conditioner with Heat Pump User's Manual
Comprehensive user manual for the OLMO Split Air Conditioner with Heat Pump, covering safety precautions, unit specifications, features, care and maintenance, and troubleshooting.
PreviewOlmo Sierra Series Remote Controller Instructions
Comprehensive instructions for operating the Olmo Sierra Series single-zone air conditioning remote controller, covering various modes, functions, and troubleshooting.
PreviewOLMO OS-EAH36-230VO Installation Manual for Central Split Air Handler Outdoor Unit
Get detailed installation instructions for the OLMO OS-EAH36-230VO multi-position AHU outdoor unit. This manual covers safety, setup, wiring, and testing for central split air conditioning systems.
PreviewOLMO Wall Mounted Mini Split Air Conditioning System: Use and Installation Manual
Comprehensive use and installation manual for OLMO Multi-Sierra wall-mounted mini-split air conditioning systems, covering models OS-RM09SW-230VI, OS-RM12SW-230VI, OS-RM18SW-230VI, and OS-RM24SW-230VI. Provides essential information for operation and setup.
PreviewOLMO Air Conditioning and Heating Products Catalog
Explore OLMO's range of high-efficiency air conditioning and heating solutions, including ductless mini-splits, through-the-wall units, and air handlers. Featuring inverter technology for energy savings and advanced features for comfort.
PreviewOLMO Sierra Series Wi-Fi User Manual
User manual for the OLMO Sierra Series Single-Zone Wall Mounted Mini Split Air Conditioning System, covering Wi-Fi setup and control via the ConnectLife app.
PreviewOLMO Multi-Zone Multi SIERRA Series Installation Manual
This installation manual provides detailed instructions for the OLMO Multi-Zone Multi SIERRA Series wall-mounted mini-split air conditioning system. It covers safety precautions, installation procedures, piping requirements, wiring, and trial runs for models OS-RMS18-230VO, OS-RMS27-230VO, OS-RMS36-230VO, and OS-RMS42-230VO.