Instruction Manual for ARROW models including: EU-25041-IR Pressure Injectable One-Lumen PICC, EU-25041-IR, Pressure Injectable One-Lumen PICC, Injectable One-Lumen PICC, One-Lumen PICC, PICC

linux, amd64

EU-25041-IR - Teleflex Incorporated - Vascular Access Product Catalog


File Info : application/pdf, 1 Pages, 506.13KB

LBL056809
EU-25041-IR

4 1 Fr.

Lumen

50cm catheter length

.018 inch dia. spring-wire guide

Pressure Injectable One-Lumen PICC

Contents:
1: One Lumen Catheter: 4 Fr. (1.45 mm OD) x 50 cm, Pressure Injectable, Blue FlexTip®
1: GlideThruTM Peel-Away Sheath: 4 Fr. x 2-3/4" (7 cm) Radiopaque over 4 Fr. Dilator
1: Spring-Wire Guide: .018" (0.46 mm) dia. x 13-1/8" (33 cm) (Straight Soft Tip on Both Ends)
1: Spring-Wire Guide, Marked: .018" (0.46 mm) dia. x 51-3/16" (130 cm) (Straight Soft Tip on One End - Straight Stiff Tip on Other)
1: Introducer Needle: Echogenic 21 Ga. x 2-3/4" (7 cm) TW 1: Syringe: 10 mL Luer-Lock 1: SecondSiteTM Adjustable Hub: Catheter Clamp 1: SecondSiteTM Adjustable Hub: Fastener 1: SharpsAway® II Locking Disposal Cup 1: Catheter Trimmer 1: Safety Scalpel: #11 1: Patient ID Card 1: Patient Information Booklet 1: Chart Sticker 1: Paper Tape Measure 1: Tourniquet 1: Dressing: GRIP-LOK®1 Catheter Fixation Device

1: Valve: MicroCLAVE®2 Neutral Displacement Connector 1A registered trademark of TIDI. 2A registered trademark of ICU Medical, Inc. All components are CE 2797 unless otherwise noted.

Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. www.teleflex.com/IFU Not made with natural rubber latex. Fluid path components are non-pyrogenic.
Contraindications: The Pressure Injectable PICC is contraindicated wherever there is presence of device related infections or presence of thrombosis in the intended insertion vessel or catheter pathway. Clinical assessment of the patient must be completed to ensure no contraindications exist.

Lumen Distal (18 Ga.)

Priming Volume*
(mL) 0.45

Gravity Flow Rate
(mL/hr) 475

Pump Flow Rate
(mL/hr) 3750

MAX Pressure Injection
Flow Rate** (mL/sec) 4

* Priming volumes are approximate and are done without accessories.  Flow rate values are approximate and are determined using deionized water at 100 cm head height.  Pump flow rates are determined at maximum pump pressure of 10 psig and represent approximate flow capabilities. ** Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing.

EU Authorized Representative and Importer: Teleflex Medical IDA Business and Technology Park Dublin Road, Athlone Co. Westmeath, Ireland
Arrow International LLC Subsidiary of Teleflex Incorporated
3015 Carrington Mill Blvd. Morrisville, NC 27560 USA
LBL056809 R00 (2021-06)

EU-25041-IR
Pressure Injectable One-Lumen PICC

4 1 Fr.

Lumen

50cm catheter length

.018 inch dia. spring-wire guide



References