WaterCop Classic Large Valve Installation Guide

A Large Valve application (1 1/2" or 2") is much the same as those less than 1 1/2", but it incorporates an industrial actuator required to torque the larger valve.

  1. Remove the WCEH Series industrial actuator from the box so you can wire it to the WCDNM.
  2. Loosen the small Allen-head screw in the side of the indicator arrow then gently pry off the indicator arrow with a screwdriver.
  3. Remove the four Allen-head bolts and take off the top cover to expose the wiring terminals. Save the gasket for step 6.
  4. Guide the leads from the WCDNM through the conduit connection in the industrial actuator and tighten the strain relief for the cord.
  5. Attach the three leads from the WCDNM to the industrial actuator as shown.
  6. Replace the gasket, cover and indicator arrow; making sure the arrow and valve position coincide.
  7. You are now ready to test the system. Please refer to the WaterCop Classic Owner's Manual.

! WARNING! The valve closes with great force and could cut off a finger. Keep fingers and other objects out of the valve when testing.

  1. After successful testing, you're ready to install the valve/ industrial actuator, and interface.
  2. The WCDNM interface is mounted indoors near the industrial actuator using mounting holes inside the case of the WCDNM.
  3. Please refer to the ‘Valve Installation' section of the WaterCop Classic Owner's Manual to install the valve; double-check that the indicator arrow and valve position coincide.
  4. Now you're ready to install the Leak Sensors. The sensors install and operate as usual. Refer to the 'Installation of Leak Sensor' section of the WaterCop Classic Owner's Manual.

WCDNM WIRING GUIDE

* Use 12 VDC actuator only

LEAD COLORTERMINAL #
BLACK1
RED2
WHITE3

(1 1/2") WCEHH27ATE25H & WCEHH28ATE25H (2")

The Proven Leader in Leak Detection & Automatic Water Shut-Off: WaterCop is there when you're not.

Models: WCEH Series, WCDNM, WCEH Series Classic Large Valve, WCEH Series, Classic Large Valve, Large Valve, Valve

PDF preview unavailable. Download the PDF instead.

Classic-Large-Valve-Installation-Guide Adobe PDF Library 19.12.68

Related Documents

PreviewWaterCop Classic Large Valve Ordering Guide
This guide provides instructions for ordering WaterCop Classic Large Valves, including system selection, sensor needs, and part numbers for 1 1/2" and 2" main water lines.
PreviewWaterCop Pro 110VAC Large Valve Ordering Guide
An ordering guide for the WaterCop Pro 110VAC Large Valve, suitable for indoor or outdoor systems with 1 1/2" or 2" main water lines. Details components like actuators, control panels, and sensors.
PreviewWaterCop Z-Wave with SmartThings Classic App: Setup and Automation Guide
Comprehensive guide to setting up and automating WaterCop Z-Wave Actuators and Leak Sensors with the SmartThings Classic App. Covers device inclusion, automation rules, and exclusion procedures.
PreviewWaterCop Pro 110VAC Large Valve Ordering Guide
This guide provides ordering information for the WaterCop Pro 110VAC Large Valve system, suitable for 3" or 4" main water lines, for both indoor and outdoor installations. It details various components including actuators, control panels, and accessories.
PreviewWaterCop Non-Motorized Control Unit (WCDNM) Dimensional Drawing
Dimensional drawing for the WaterCop Non-Motorized Control Unit (WCDNM) by DynaQuip Controls Corporation, detailing its dimensions, cable lengths, and sensor probe connections.
PreviewWaterCop DC Pro Large Valve Outdoor Ordering Guide
Ordering guide for WaterCop DC Pro Large Valve Outdoor systems, specifying components for 1 1/2" and 2" main water lines, including actuators, control panels, and connect cables.
PreviewWaterCop Pro 1 1/2" & 2" Large Valve Installation Guide
A guide for wiring placement for the WaterCop Pro 1 1/2" and 2" Large Valve, featuring an industrial actuator. It provides step-by-step instructions for connecting the actuator, cable, and control panel, along with important safety warnings.
PreviewWaterCop Classic LEAK Sensor: Technical Specifications and Wiring
Detailed technical specifications and wiring diagram for the WaterCop Classic LEAK Sensor, including enclosure details, power requirements, sensor probe information, and frequency.