Secop GS26GHX Compressor Technical Data
Compressor Design and Specifications
Model | GS26GHX | |||
---|---|---|---|---|
Designation | 220-240V/50Hz 1~ | |||
Sales code | 107B0702 | |||
Compressor design | Oil type | Polyolester | Refrigerant(s) | R134a, R513A |
Oil viscosity | 32,5cSt | Displacement | 26,3cm³ / 1,6cu.in | |
Oil quantity | 902cm³ / 30,5fl.oz | Compressors on pallet | 48 | |
Refr. charge - tech. limit | 2000g / 70,5oz | |||
Free gas volume comp. | 3350cm³ / 113,3fl.oz | |||
Weight | 19,1kg / 42,1lbs | |||
Motor protection | 1# internal | |||
Winding resistance main | 2,5Ω (at 25°C) | |||
Winding resistance aux | 6,7Ω (at 25°C) | |||
Max. winding temp. | 130°C / 266°F | |||
Max. discharge temp. | 130°C / 266°F |
General - Configurations with GS26GHX
Parameter | Conf. 1 | Conf. 2 |
---|---|---|
Motorconfiguration | CSCR | CSCR |
Power supply (nominal) | 220-240V/50Hz | 220-240V/50Hz |
Number of phases | 1 | 1 |
Voltage range | 198-254V | 198-254V |
Approvals | VDE | VDE |
Starting torque | HST | HST |
Note | Cover, clamp, gasket: pre-assembled to compressor. |
Applications with GS26GHX
Parameter | Conf. 1 | Conf. 2 |
---|---|---|
Refrigerant | R134a | R513A |
Application | MBP+HBP | MBP+HBP |
System cooling | fan 3m/s | fan 3m/s |
Hot gas defrost | OK | OK |
Long interval pull down | OK | OK |
Electrical data - Configurations with GS26GHX
Parameter | Conf. 1 | Conf. 2 |
---|---|---|
Starting device type | relay | relay |
Run capacitor | 20μF | 20μF |
Start capacitor | 80μF | 80μF |
LRA (locked rotor amps / 4s/ U(N)) | 40A | 40A |
RLA (rated load amps / 1s/ U(N)) | 5,6A | 5,6A |
Cut in current (U(N)) | 40A | 40A |
Dimensions and Fixation
Compressor Dimensions
Dimension | Value (mm) | Value (in) |
---|---|---|
A Height | 259 | 10,2 |
B Height | 247 | 9,72 |
C Length shell | 224 | 8,82 |
D Length w. cover | 232 | 9,13 |
E Width | 173 | 6,81 |
Connectors
Connection | Diameter (i:inside, o:outside) | Material | Horizontal angle | Vertical angle | Position l/h/w |
---|---|---|---|---|---|
[mm] / [in] | [mm] / [in] | ||||
Suction (X) | øi 12,75-13,05 / øi 0,5-0,51 | copper | ±2° | ±2° | -95/234/-84 / -3,7/9,2/-3,3 |
Discharge (Y) | øi 8,15-8,25 / øi 0,32-0,32 | copper | 0° | 90° | -105/84/-84 / -4,1/3,3/-3,3 |
Process (Z) | øi 6,4-6,6 / øi 0,25-0,26 | copper | 0° | 71° | 95/234/84 / 3,7/9,2/3,3 |
Compressor Fixation
Bolt joint
Diagram shows a bolt joint assembly. Components include: Washer, Compressor base, Nut, Sleeve, Bolt, Rubber grommet, Cabinet base.
Part | [mm] | [inch] |
---|---|---|
Baseplate (BI) | 235 | 9.25 |
Baseplate (Bw) | 154 | 6.06 |
Baseplate (ØE) | Ø 3.6 | Ø 0.14 |
Large holes (LI) | 203 | 7.99 |
Large holes (Lw) | 122 | 4.80 |
Large holes (ØL) | Ø 19 | Ø 0.75 |
Mounting Accessories
Bolt joint | M8 | ø19mm - one comp. 107B9150
Application notes
Provision for PE Grounding is located at the PE Stamp on the compressor.
Operating Conditions and Performance Data
Ambient and Machine Room Temperatures
Ambient temperature range: 10 - 43°C / 50 - 110°F
Machine room temperature range: 10 - 48°C / 50 - 119°F
Compressor cooling: fan 3m/s
Operation Pressure Range
Graphs illustrate the operation pressure ranges for condensing and evaporation pressures. These graphs define the boundaries for continuous and transitory operation based on temperature and pressure.
Optimization + Standard Conditions
pe | pc | RGT | Tliq | Cooling capacity | COP | Power consumption | Current consumption | Ref. mass flow [kg/h] | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | ||||||||
R134a, 220V/50Hz, CSCR, fan 3m/s, VDE | |||||||||||||||
[°C] 7 | 54 | 35 | 46 | 2611,8 | 8920 | 2247,8 | 2,50 | 8,53 | 2,15 | 1046,1 | 4,91 | 57,94 | ASHRAE HBP | ||
[°F] 45 | 130 | 95 | 115 | ||||||||||||
[°C] 5 | 55 | 32 | 55 | 2151,8 | 7349 | 1851,8 | 2,13 | 7,27 | 1,83 | 1010,8 | 4,75 | 53,02 | cecomaf HBP | ||
[°F] 41 | 131 | 90 | 131 | ||||||||||||
[°C] 5 | 50 | 20 | 50 | 2234,8 | 7632 | 1923,3 | 2,30 | 7,87 | 1,98 | 969,7 | 4,56 | 56,31 | EN12900 HBP | ||
[°F] 41 | 122 | 68 | 122 | ||||||||||||
[°C] -7 | 54 | 35 | 46 | 1446,7 | 4941 | 1245,1 | 1,79 | 6,11 | 1,54 | 808,7 | 3,84 | 31,56 | ASHRAE MBP | ||
[°F] 20 | 130 | 95 | 115 | ||||||||||||
[°C] -10 | 55 | 32 | 55 | 1119,2 | 3822 | 963,2 | 1,48 | 5,05 | 1,27 | 756,5 | 3,62 | 27,06 | cecomaf MBP | ||
[°F] 14 | 131 | 90 | 131 | ||||||||||||
[°C] -10 | 45 | 20 | 45 | 1273,3 | 4349 | 1095,8 | 1,78 | 6,07 | 1,53 | 716,7 | 3,42 | 29,80 | EN12900 MBP | ||
[°F] 14 | 113 | 68 | 113 |
Performance Tables (R134a)
pe | pc | RGT | Tliq | Cooling capacity | COP | Power consumption | Ref. mass flow [kg/h] | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | ||||||
R134a, 220V/50Hz, CSCR, fan 3m/s, VDE | |||||||||||||
[°C / °F] | |||||||||||||
cond. pressure | -15 / 5 | 1039,9 | 3552 | 895,0 | 1,60 | 5,46 | 1,38 | 650,0 | 3,15 | 22,67 | |||
pc= 45/113 | -10 / 14 | 1321,0 | 4511 | 1136,9 | 1,84 | 6,29 | 1,59 | 716,7 | 3,42 | 28,91 | |||
return gas temp. | -5 / 23 | 1656,9 | 5659 | 1426,0 | 2,11 | 7,21 | 1,82 | 784,7 | 3,72 | 36,44 | |||
RGT= 32/90 | 0 / 32 | 2055,5 | 7020 | 1769,0 | 2,40 | 8,21 | 2,07 | 855,4 | 4,04 | 45,46 | |||
liquid temp | 5 / 41 | 2524,4 | 8621 | 2172,6 | 2,71 | 9,27 | 2,34 | 930,1 | 4,38 | 56,20 | |||
Tliq= 45/113 | 10 / 50 | 3071,5 | 10490 | 2643,4 | 3,04 | 10,38 | 2,62 | 1010,2 | 4,75 | 68,92 | |||
15 / 59 | 3704,4 | 12651 | 3188,0 | 3,38 | 11,53 | 2,91 | 1097,2 | 5,14 | 83,91 | ||||
cond. pressure | -15 / 5 | 877,4 | 2996 | 755,1 | 1,30 | 4,44 | 1,12 | 674,6 | 3,29 | 21,12 | |||
pc= 55/131 | -10 / 14 | 1119,2 | 3822 | 963,2 | 1,48 | 5,05 | 1,27 | 756,5 | 3,62 | 27,06 | |||
return gas temp | -5 / 23 | 1407,0 | 4805 | 1210,9 | 1,68 | 5,73 | 1,44 | 838,9 | 3,97 | 34,20 | |||
RGT= 32/90 | 0 / 32 | 1748,6 | 5972 | 1504,9 | 1,89 | 6,47 | 1,63 | 923,2 | 4,35 | 42,77 | |||
liquid temp | 5 / 41 | 2151,8 | 7349 | 1851,8 | 2,13 | 7,27 | 1,83 | 1010,8 | 4,75 | 53,02 | |||
Tliq= 55/131 | 10 / 50 | 2624,1 | 8962 | 2258,3 | 2,38 | 8,12 | 2,05 | 1103,1 | 5,18 | 65,23 | |||
15 / 59 | 3173,5 | 10838 | 2731,1 | 2,64 | 9,02 | 2,27 | 1201,5 | 5,62 | 79,71 |
Performance Tables (R513A)
pe | pc | RGT | Tliq | Cooling capacity | COP | Power consumption | Ref. mass flow [kg/h] | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | ||||||
R513A, 220V/50Hz, CSCR, fan 3m/s, VDE | |||||||||||||
[°C / °F] | |||||||||||||
cond. pressure | -15 / 5 | 1105,5 | 3776 | 951,4 | 1,60 | 5,47 | 1,38 | 689,6 | 4,19 | 27,09 | |||
pc= 45/113 | -10 / 14 | 1391,6 | 4753 | 1197,6 | 1,84 | 6,29 | 1,58 | 755,8 | 4,51 | 34,21 | |||
return gas temp. | -5 / 23 | 1731,4 | 5913 | 1490,1 | 2,11 | 7,19 | 1,81 | 822,1 | 4,82 | 42,74 | |||
RGT= 32/90 | 0 / 32 | 2132,3 | 7282 | 1835,1 | 2,39 | 8,17 | 2,06 | 890,8 | 5,13 | 52,89 | |||
liquid temp | 5 / 41 | 2601,7 | 8885 | 2239,1 | 2,70 | 9,21 | 2,32 | 964,4 | 5,45 | 64,89 | |||
Tliq= 45/113 | 10 / 50 | 3147,0 | 10748 | 2708,4 | 3,01 | 10,28 | 2,59 | 1045,3 | 5,80 | 79,01 | |||
15 / 59 | 3775,6 | 12894 | 3249,3 | 3,32 | 11,35 | 2,86 | 1135,8 | 6,18 | 95,53 | ||||
cond. pressure | -15 / 5 | 919,2 | 3139 | 791,0 | 1,29 | 4,39 | 1,11 | 715,3 | 4,31 | 25,32 | |||
pc= 55/131 | -10 / 14 | 1160,9 | 3965 | 999,1 | 1,46 | 4,97 | 1,25 | 797,2 | 4,70 | 32,10 | |||
return gas temp | -5 / 23 | 1446,8 | 4941 | 1245,1 | 1,65 | 5,62 | 1,42 | 878,5 | 5,07 | 40,19 | |||
RGT= 32/90 | 0 / 32 | 1784,2 | 6093 | 1535,5 | 1,86 | 6,34 | 1,60 | 961,7 | 5,44 | 49,83 | |||
liquid temp | 5 / 41 | 2180,4 | 7447 | 1876,5 | 2,08 | 7,10 | 1,79 | 1049,0 | 5,82 | 61,28 | |||
Tliq= 55/131 | 10 / 50 | 2642,9 | 9026 | 2274,5 | 2,31 | 7,90 | 1,99 | 1142,9 | 6,21 | 74,82 | |||
15 / 59 | 3179,2 | 10857 | 2736,0 | 2,55 | 8,71 | 2,20 | 1245,8 | 6,63 | 90,79 |
Wiring Diagram and Color Codes
The diagram shows the electrical connections for the compressor. Key components include the starter kit (a3), cover (b), gasket (b2), clamp (b1), winding protector (e), and fan. The diagram illustrates connections for the main winding, start winding, and a bleeder resistance. Terminals are labeled S (Start), C (Common), and R (Run). The diagram also indicates the color coding for wires: Earthing (yellow/green), Start (black), Common (brown), and Run (blue or grey).
ENGLISH | DEUTSCH | FRANÇAIS | ESPAÑOL | ITALIANO | NEDERLANDS | DANSK | SVENSKA | SUOMEKSI | РУССКИЙ | 中文 |
---|---|---|---|---|---|---|---|---|---|---|
S (Start) | Schwarz (Start) | Noir (Démarrage) | Negro (Arranque) | Nero (Avviamento) | Zwart (Start) | Sort (Start) | Svart (Start) | Musta (Käynnistys) | Чёрный (Пуск) | 黑色 (启动) |
C (Common) | Braun (Common) | Marron (Commun) | Marrón (Común) | Marrone (Comune) | Bruin (Common) | Brun (Fælles) | Brun (Gemensam) | Ruskea (Yhteinen) | Коричневый (Общий) | 棕色 (公共) |
R (Run) | Blau od. grau (Lauf) | Bleu ou gris (Marche) | Azul o gris (Marcha) | Blu o grigio (In funzione) | Blauw of grijs (Loop) | Blå eller grå (Kørsel) | Blå eller grå (Körning) | Sininen tai harmaa (Käyttö) | Синий или серый (Рабочий) | 蓝色或灰色 (运行) |
Earthing (yellow/green) | Erdung (gelb/grün) / Mise à la terre (jaune/vert) / Puesta a tierra (amarillo/verde) / Messa a terra (giallo/verde) / Aarding (geel/groen) / Jordforbindelse (gul/grøn) / Jordning (gul/grön) / Maadoitus (keltainen/vihreä) / Заземление (желто-зеленый) / 接地 (黄/绿) |